Certification for Design Load Compliance
Project Name:
Project Address: 35'1 kei,vc- F 51,. L�c,, 6.-,6 , jzl- St. Luci"e 1 cour7l�y
Permit #: Occupancy Type: Construction
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
0 New Residences (single or multi -family)
o Residential Addition
• Any accessory structure requiring a building permit
• Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida � A; 14 1, 5 Code Fifth Edition with 20_ ln,_Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed —Partially Enclosed —Open
3. Risk Category: I -g 11 111 IV Exposure Category: _B X C D
_ __ _ _ _ -2- —
4. Design Wind Velocity 1-70 mph —ASD Y, LRFD EndZoneWidth:- IL -oft
S. Mean Roof Height I G Roof Pitch: f/ :12 Parapet: -N-L&--ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sqft @ 15'MRH, clearly label on all plan openings):
Zonel: 31.9 Zone 2: & 0-& Zone3: &(;-b Zone 4: '35�O Zone5: 3-0-3 Garage:
7. Design Loads: Floor: rJ fA PSF Roof/Dead: 95 PSF Roof/Live: 30 Balcony: J�J//A PSF
Dock: PI 1A PSF Deck:_!�/A PSF Stairs: :J(A PSF Fence: Al/A P.SF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? Y Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? ',< Yes _NotApplicable ExplainWhyNot:
10. Design Soil Bearing Pressure: 26'00 PSF Soil Test Reports Submitted? _-�< -Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
- 12f, I I I IN —
SlgnaturA/Dat�, an'd Seal
Revised 07/25/2014
5"WA 64 Is 50
Print Name Cert # & Co. Cart Auth.
CR,AA)r,�
.;ao A�e.
P'I' f&'J' "A(�.C. q ri3
Company Name & Address