Loading...
HomeMy WebLinkAboutDESIGN CERTIFICATION - WIND LOAD COMPLIANCE66191 St. Lucie County Building and Zoning Department 2300 Virginia Avenue Fort Pierce, FL 34982 -1724624553 SCA1%,ED St. Lu "y --cie county Design Certification for Wind Load Compliance This Certification is to be completed by the project design architect or engineer. This Certification must be submitted with all applications for building permits involving the construction of new residence (single or multi- family), residential addition, any accessory structure requiring a building permit, and any nonresidential structure. This Certification shall not apply to interior renovations (provided dig no structural walls, columns or other similar component is being effected) and certain other minor building permits. For firither assistance, please contact the Building Inspection Office at 462-1553 or 462-2172. WqVn.09&Uc,#JAt- AOGWL�4S Project Name Office e Only Us Street Address ft-Kt-�-at Evzo Pertnit Number 9' 1 Occupancy Type I I Construction Type Certification Statement: I certify that, to the best of my knowledge and belief, these plans and specifications have been designed to comply with the applicable structural portion of the Building Codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate re . tance to the wind loads and forces specified by current code provisions. Desien Parameters and Assumptions Use V:Please check or complete th pp �atclb x.) 1. Florida Building Code 2004 Edit--- ASCE 7- 1 2. Building Design is (check one) Enclosed V Partially'"Clos Open Building '^ % -7 3. Building Height: Z-5 4. Wind S I *ng Design: 14votipLi second gust 1% d* % ore I g 5. Wind Exposure Classification (refer to expos n Code identified in Line #1): C- 6. Average Wind Velocity Pressure on Exterior Faces of Structure PSF 7. Peak Wind Velocity Pressure on Exterior Faces of Structure PSF S. Importance/Use Factor (obtain from Building Code): 1.0 9. Loads: Floor PSIT Rool7dead -25 PSF Roofflive PSF 10. Were Shear Walls Considered for Structure (check one): Yes V No if No, attach explanation) 11. is a Continuous Load Path Provided (check one): Yes No _ (if No, attach explanation) 12. Are Component and Cladding Detail Provided (check one): Yes %," No—OfNo,attacherplanation) 13. Minimum Soil Bearing Pressure: 2506 PSF As witnessed by my seal, I hereby certify that the information included with this certification is trua and correct, to the best of my knowledge and belieE Name: 17, C.J" Aaz UAFPS I �-) C- Certification #: A&S 2-9 (Seal Here] Design Firm:-2t'C-1q'&!LQ 06b'JC'I 0 C. Date: ID 1-0 1QA'-VJ&t5 IPA. SLCCDV Form 020-00 1015105 dmg rev. 4