Loading...
HomeMy WebLinkAboutHALF MILE PAPERWORK,osYs� 2 - opcc-X ROOF TRUSSES HALF MILE INDUSTRIES LLC.f WALL V 9500 WEST ATLANTIC AVE. P'LS DELRAY BEACH, FL 33446 j., PH: 561-499-1090 oon 19-06 CUSTOMER NAME: IVIDM BUI JOB NAME: BUILDING #1 _ JOB#: B0190 RAISED-S EDP VPERMTPNG UT SEAL LD RAISED ffjL INSPECTrOA X41v 40 ` +1 A� 5 lad �„ • jai®i2�f�' ate` J Q ROOF TRUSSES HALF MILE INDUSTRIES LLG. — ALL PANELS Junell,2009 MDM Builders 1412 SW 34th Ave. Deerfield Beach, FL 33442 Phone 954-427-3076 Fax 954-427-3420 Half Mile Industries, L.L.C. 9500 W. Atlantic Avenue, Delray Beach, Florida, 33446 www.halfmile.us Phone-(561) 499-1090-- Fax (561) 368-8037 Subject Truss Engineering Specifications Job # B0190 Bldg. l Model Lot/Block /Section International Airport Business Park Address Occupancy Group: Commercial Occupancy Category: ❑ (Residential) Exposure Category: C Wind Speed: 140 Enclosure ClassiAcation: Enclosed St Lucie Blvd &Cayuga Blvd �� F[. Pierce, Bldg. 1 h. Please find attached: 1. Truss Placement Diagram with truss to tins con ule (If Applicable) 2. Reaction Summary (Index of attached draw[ gs Loads on Structure) 3. Engineering Summary sheet for each truss. 4. Standard Details (If applicable) This cover sheet will serve as a blanket certification for all the attached items under Rule 61G15-31.003 of the Florida Department of Professional Regulation using design criteria from the FBC 2007 Edition. I Certify that all Half Mile Industries, L.L.C. truss specifications are designed for wind load calculations using ASCE 7-05 which has been adopted by FBC 2007 Edition. The items are enclosed and bound together. If the truss placement diagram is mirrored for an alternate garage right/left swing these truss specifications will remain unchanged. Alpine is the computer program used for engineering these trusses. Should you have any questions concerning this engineering, please do not hesitate to contact us at 561499-1090. Please have the job number available and request to speak to the truss designer whose name is indicated at the bottom of your truss placement layout so that we may better serve you. Truss Design Engineer Steve W. Warter, PE Florida License #54395 Structural Engineer of Record: Name: License #: Address: Reviewed per rule 61G15-30.006 (3) JobKey: B0190 ,Company: HALF MILE INDUSTRIES LLC Address: Phone: Site Address: SUPPORT REPORT JOB DESCRIPTION: B0190 WINb CODE: ------- WIND MPH: 140 BLDG TYPE: CLOSED TRUSS TRUSS SUPPORT SUPPORT BEARING BEARING REACT. REACT. MAX WIND DESC SPAN-ft SIZE -in. TYPE XLOC-ft. YLOC-ft. MAX.+# MAX.-# UPLFT.-# Al 43.00 8.00 WALL 3.000 12.667 5963 -2222 Al 43.00 8.00 WALL 42.333 12.667 2712 -1282 -------------------------------------------------------------------------------- A1G 43.00 24.00 WALL 1.667 12.667 11458 -4914 A1G 43.00 8.00 WALL 42.333 12.667 3709 -1754 -------------------------------------------------------------------------------- AlA 43.00 8.00 WALL 3.000 12.667 8267 -3315 AlA- - -.: 43.00 -8.00, WALL----42-.333---12.667 -3000- -1419 -------------------------------------------------------------------------------- A1B 43.00 8.00 WALL 3.000 12.667 7276 -3440 A1B 43.00 8.00 WALL 42.333 12.667 3052 -1443 -------------------------------------------------------------------------------- A5G 40.00 8.00 WALL 0.000 12.667 5977 -2682 A5G 40.00 8.00 WALL 39.333 12.667 5977 -2682 -------------------------------------------------------------------------------- EJ9 10.00 8.00 WALL 0.000 12.667 745 -170 EJ9 10.00 3.00 *HANGER 9.750 12.667 540 -454 -------------------------------------------------------------------------------- HJ9 14.08 10.56 WALL 0.000 12.667 1199 -686 HJ9 14.08 3.00 *HANGER 13.830 12.667 1744 -852 -------------------------------------------------------------------------------- CJ5 5.00 8.00 WALL 0.000 12.667 495 -195 CJ5 5.00 1.50 NAILED 5.000 12.667 -203 CJ5 5.00 1.50 NAILED 5.000 18_29b -181 ---_---------------------------------------------- ---------------- A3 40.00 8.00 WALL 0.000 1 5 -1225 -A3_ __________-40_00 8.00 WALL-----39.33 -1 .66636______-___-_1225 ----------------- - - CJ3 3.00 8.00 WALL 00 12.667 396 -274 CJ3 3.00 1.50 NAILED 12.667 258 -309 CJ3----------- -3.00 1.50 NAILED 3 0 17.458 73 -81 ---------------------- --------------------------------------- CJl 1.00 8.00 WALL 0.000 12.667 600 -644 CJl 1.00 1.50 NAILED 1.000 12.667 668 -72 -704 CJ1 1.00 1.50 NAILED 1.000 16.625 86 -72 -64 --- T---------------------------------------------------------------------------- A4 40.00 8.00 WALL 0.000 12.667 2385 -1080 A4 40.00 8.00 WALL 39.333 12.667 2386 -1083 -------------------------------------------------------------------------------- A6 40.00 8.00 WALL 0.000 12.667 2636 -1226 A6 40.00 8.00 WALL 39.333 12.667 2441 -1135 -------------------------------------------------------------------------------- CJ9 9.00 8.00 WALL 0.000 12.667 ,691 -166 CJ9 9.00 - 1.50 NAILED 9.000 12.667 212 -174 CJ9 9.00 1.50 NAILED 9.000 19.958 270 -256 CJ7 7.00 8.00 WALL 0.000 12.667 594 -160 1 I 1 1 1 1 1 I 1 1 1 xxx I b7dOWbChO07b7b7b71 nn 1 nnn 1 nn 1 nn 1 nn 1 nnn 1 xxxx 1 rromaommt>,mmm 1 nn 1 nn � nn � mm ��nn 4441rrrrrrrrr1441444144144141.1 U1 I 41444144441NNNNNNNNNlca414�144I44I44, I In UI I UI UI U1 I w W I W W I UI U1 VI VI J J J I UU 1 yb I b7tp I Gl7 1 nn 1 tilWW 1 4]4]G�G�G]GlG]4)4l ; nn i y?r 1 yr7y i vv i aa, c 1 I 1 1 1 I 1 I 1 1 1 I I 1 I I 1 I I 1 1 1 I I 1 I I 1 I I 1 I 1 I i I I 1 1 I I I I 1 1 I 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I 1 i 1 1 11 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 I 1 1 1 1 I I I I 1 1 I I I 1 1 I 1 1 I I 1 1 I I N N N N N N N N N I 1 1 I I 1 I I N N N N N N N N N I 1 t 1 1 10101D r NN NN NNN NN 1 UI UI t U7 U1 UI 1 W W 1 ww I to Ul I U1 UI U1 1101O �O 10 1 NNNNNNNN N I W W 1 w W I HH I �1J 1 JJ • I- I I 1 i I I I I 1 I I I I W W W P 01 01 01 01 01 01 01 O1 Q1 I r r I NNN 1 N N t N N I W W I W W W I OD W W W I 01 0� 0� 0� 01 01 01 01 01 I W W I W W I W W I 0 0 10 0 IP IP IP 1. F-I H F-I H H I-+ r r r I OD W 1 NNN 1 ww I W W I ww I www I IP IP IP IP 1 NNNrrrrrr 1 1p 1p I ww I ww 1 00 1 00 f 1 I I I I I I I I I I I 1 1 1 1 I I I I I I I 1 I I I I' I LA) I I I r l W I I I I r l I I Ul I rrrrrrHrHrrrrlrmlrrwlrrlrNlrWlHrwlHHrrll1rrrHHrHrIrIP1HH1Hrlralrr 1 i 1 1 I 1 I 1 I 1 1 1 1 1 U7 U1 U1 1 U7 U1 U1 U1 In UI U1 U7 U1 I U7 O I UI N U1 I N U1 I U1 O I Ui O I U1 VI !P 1 U1 U1 UI U7 I U1 U1 U1 U1 61 UI 61 61 61 I U1 O I In U1 1 UI U1 I U1 W I U1 In O O O I 0 0 0 0 0 0 0 0 0 1 O O I O O O I O O I O 0\ I O O I O O O I O O O O I O O O O O O O O O I O O I O O I O O I O H I O O 1 f I 1 1 1 1 I I 1 I I I I 1 I I 1 I 1 I I I 1 1 1 1 I 1 ,����£ I z� 17iz 17iz I zip+ 1 ZZ H HI H H I H I H r I H H I H H r I I H r l H H I H H I H 1 H H r r r I r r r r r r r r r 1 r r r I r r I r r I r r I r r r I 0000 I r r r r r r r r r l r r 1 r r 1 r r I r r l r r m I m m m m I m m I m m m m m m m 1 m m 1 m I m m 0 r I C7 tJ 1 C C I t7 1 C7 I C7 CJ 1 C7 t7 1 I C7 I C l7 a C7 l7 I t7 I C7 01 1 I 1 1 1 1 1 1 I 1 I I 1 1 I 1 1 1 1 I I I 1 1 1 1 1 I I HHrlrr I MI w l IP I W TIPNOl0 -1 U7 W I Ul W I W W I W N I UIN I UI UI W I 1010JofMAWO� I Q11Pl0 < Ul W I W N I W W 1 rr I 1N I -4 -] 0] l W O I NNN NUN: 00 W mw I li -4-1-3 w w ww I NN I N I W W I W N I ON 1 10O10 I W W 01 W I .J%J �J J-3 W Wto IO 1 ON I WW I 1010 1 0 N 1 00 �l InJ 1 IPIP IPIP IPtoWWIW 1 AIP I IP rr 1 rIP 1 NIP I HNH I %J-1Hw I IP IP IP IP IP lD lO lO l0 1 NIP I rr I Hr 1 OIP 1 00 I 1 1 1 1 1 1 1 1 1 I i 1 1 I 1 1 I 1 1 I 1 1 1 1 I I I 1 1 1 I 1 I 1 1 I I I 1 N to N I N N to N N N N to toI to M I NJ N N I N N I N N I N N N I N N N N I N N N N N N N N N I N N I N N I N N I N N I r r NNN I NNNNNNN NN 1 NN 1 NU1 I IP I IN I U1N I NUIN I U1NNN I NNNN NNNNN I IN I IPN L N W I U1N I lON mmm l mmmmmmrnmrn l om l mo• 1 I Nm l Hm 101H01 I Wmmm 1 0immmmm'al rnm I Nm I wm I m'P I Wm I Hm 0)0101 1 010101 a\ 410101 at m 1 mm 1 mm 1 W M I N01 I MNM I H010101 I MMMMMMMM01 I W M 1 0M 1 01M I NM I NM aaa 1 aaaaaaaaa 1 Pa 1 -3IPa 1 w-4 1 ra I ar.11 Oaaa 1 aa%Jali aaa13 1 as 1 0-4 1 as 1 00 .1 1 UI%I 1 I I 1 1 1 1 I I 1 1 1 1 1 1 1 I 1 1 1 1 I 1 1 1 1 I I 1 1 1 1 I 1 1 I 1 1 1 1 1 1 1 I 1 1 1 r r 1 1 1 1 1 r W I -4 r N IA H at 1 . U7 I r W I r N I N 1.1 I Ul I r l0 I r N lD I IP N 01 r O\ W I Ul I N r 1 H l r ON i N r W W IP I W �l lP 1p 01r H4110 I N� I W Ul I H W I Or I W J I 10r0 I ONIDr l rO0�UI r1p W U701 1 l0J I Tr I OlO I W 01 I rl0 l0 elm I W �IHUI UIOHW O\ I NIP I N W W I W 01 I IO UI I W N I W W �l 1 dtN W W I rONUI W IPN W O I W U7 1 <DH 110r I w W 1 01O 1 I 1 I I I I 1 I I 1 I 1 I I I I I I I I 1 I 1 1 1 I I 1 1 1 I I I I I I 1 I I I I I 1 I I W 1 I N 1 1 I H 1 I I 1 I I 1 dl 1 I I !P I I� 1 1 I I� I 1 1 I 1 1 1 J O I I W I 1 UI W I I . I IP I I I I I I 1 I I I 1 I 1 I 1 I I I 1 I 1 I I I 1 I 1 I I I I I I I I I I I 1 I I I I 1 I I 1 1 1 1 1 I I I 1 1 1 1 I I I I I I I I I 1 1 I I I I 1 1 1 I 1 I I I I I I 1 1 1 1 1 1 1 r W I U1 I I N W IP I r N I N I A l I r 1 N W I r N I N I IP I H H I I to U N I r N 1 r I 1 1 1 1 H w 1 N r WPM 1 IP W IP U7 rUl I Nl0 I rw I W NH 1 IO w1 -701 I N W 1 U1NIP 1 N01 I w 0 I IPOIPN W lOrr 1 N01 I Olv 1 to W I 000 1 rJ r NN I W W l0 W W Ul�7Ul W 1 �1N I W W N I W O I IPN I N W 1 10OU1 1 OH1001 I NIP IP W W NO�IUI I W W I UI10 1 IPr I W H 1 NJ HJ7A 9.84 1.50 NAILED 9.837 25.810 123 -139 ------------------------------------------------------------------------------- ------------------------------------------------------------------------ *HANGER denotes a hanger calculated by the layout program. Refer to the layout HANGER SCHEDULE for complete list of hangers and nails required. ------------------------------------------------------------------------ a."rH L F e� t i i , VIA In ,..(.... •_ .. 1. OAK, : - n • u Topp chord 2x6 SP SS :T3, TO 2x6 SPA #2: :T5 2x4 SP #2: So Y chord 2x6 SP SS Webs 2x4 SP #3 :W1 2x8 SP SS: :W2 W3 WS, W7 WS 2x6 SP #2: :W4 2x6 SP SS: :W9 2x4 SP #2 Dense: :W10, 00 2x4 5l� #2: :W24 2x4 SP SS: :Rt Level Return 2x4 SP #2: nebUfl1?oLRT2UPfl1TC - From258PLFat 000t58LFat 2.95 TC - From 70 PLF at 2.95 to 70 PLF at 11.96 TO - From 258 PLF at 11.96 to 258 PLF at 15.04 TC - From 70 PLF at 15.04 to 70 PLF at 26.04 TC - From 70 PLF at 26.04 to 70 PLF at 32.83 TC - From 73 PLF at 32.63 to 73 PLF at 45.10 BC - From 40 PLF at 0.00 to 40 PLF at 5.25 BC - From 60 PLF at S.25 to 60 PLF at 9.71 BC - From 40 PLF of 9.71 to 40 PLF at 13.08 SC - From 40 PLF at 13.88 to 40 PLF at 28.81 BC - From' 40 PLF at 28.81 to 40 PLF at 42.81 PLB- From 4 PLF at, 42.85 to 4 PLF at 44.83 TO - 12 LB Cono. Load of 2.95, 11.86 TO - 200 LB Cono. Load at 4.65, 10.27 TC - 55 LB Cono. Load at 6.65, 8.27 ID PITCH ------LUMBER------ RXL BNO CSI LOC-ft FORCE T1 0.0 2.6 SP SS 0.01 0.23 0.30 3.33 14 T1 0.0 2x6 SP SS 0.03 0.31 0.34 12.08 -1501 T3 -0.3 2x6 SP #2 0.52 0.31 0.84 17.66 -6599 T4 -0.3 2x6 SP #2 0.51 0.16 0.67 30.70 -6599 TS -5.0 2x4 SP #2 0.22 0.53 0.74 42.94 -1958 81 0.0 2x6 SP SS 0.13 0.16 0.29 3.33 805 82 0.0 2x6 SP SS 0.77 0.111 0.91 16.52 6388 B3 0.0 2x6 SP SS 0.75 0.08 0.84 24.20 6563 B4 0.0 2x6 SP SS 0.56 0.10 0.66 30.96 5823 Member design based on both 11WFRS and C&C, wind reactions based on t1W Calculated horizontal deflection Is 0.48' du Ive load and 0.3$ load. CO) Continuous lateral brooing equally epaoed bar. Or 24 11 3 ' brace. BOX ",m nq. of web member. flitnched ul x or GuB'S'9 II race.'SOX I nyth node # em er. i no* WRRNINGI CSI EXCEEDS 1.00 (999.003 I ' Bear Inq blocks: Nall type: 0.120"x3"-Gun-naile BRG R3LOOCCO• #BLOCKS 'LENGTH/BLK #NRILS/BLK WALL PLATE ' 12" 5 Rigid Surface Bearinpp block to be some size and species as bottom chord.) Refer Tc drawing CNBRGBLK0207 For additional Information. .. The maximum horizontal reaction Is 1955# •+ ' CI1 - plates so marked Lore sized using a Fabrication Tolerance of OX and a Rotational Tolerance of10 deer..._ 140 mph wind, 19.12 Ft mean hqt RSCE 7-05 CLOSED bids, not located within 6.50 Ft from roof edge, CRT II, EXP 0, wind TO OL-5.0 par, wind BC DL-5.0 per. Iw-1.00 GCPl (+/-1-0.18 ! I End ver?fools exposed TO wind pressure. Deflaotion meats L1240 criteria for brittle and flexible wall coverings. (C1 Continuous lateral Praoing equally epooed on member. Or lx4 #3SRB SPF-S or better T" brooe. BOX length of web member. Attached with Bd Box or Gun (0.113"x2.5",min.)notlsjO 6" CC. JW,2 5 00 # 50# 50#C m 5 N al+ 8-0"15 AU I C +SN+# 14'9"4 -15 4XI4 � � I 7+ 803--P8C17COOZ'`3L a-V47RSS + 148 + W133DF 8X8 CR] 12 ''0.25 Q 5 of W19 8X8 4X4 I CBJ Y J �J 3 RJ T4 1 X11 X6 TS W24 O W W (RJ BJ X84X4 I W 3'10'^ 31915 I X4 1 t v 2X4 I10'14 5X6 2X4 HQ310 SQL viu 42•Id-8 R=7276# U=3440# RL=1385/-1593#' W=8" R=3052# ifi10 `�' j Ny U=1443# W=8- LEFT JIG 17'11-8 9 RIGHT RAKE - 2'4-4 TAG - T27 `��OOOO#O######' RIGHT JIG _= 12'10"6 PLT. TYP. -WRVS oEe1aN allTrteC2W)CWIP1-2ooz Fr/Rr-zormo/1oNm OTY- 2 TOTRL- 2 \ � # /� REV. 8.07.00.1218. BEALE 0.0973 e�CING. EREFER mS�BGSII (B�)RE IILDING aEimm�TINSAFETYIIINNTFIXIMTloni'IPuALIs9GIeY'TP"1 .TAuss INSTITUTE 218 NOUN LEE STR. SMITE 312, IdE%WIDRIB VR. 223141 AND VTCR ......... ••�.,•� TO LL S E 20.Opsf REF ROOF NfV10 TRU93 DF RKERIM GOO ENTERPRISE CA, AbISON WI. 537191 PON SRFETY PRACTICES PRIOR TO THESE F18NCIION9. ONLEBS GG V� • , TC OL 15. Opsf DATE 06-11 -2009 .. TRUSSES OTHERWISE IISI�IRTED TOP CNOAD SHALL NAVE PROpEALY ATTACIEO 8 PTw NTTDN CHORD SHALL HRVE A PROPQ) y ATTAClED RIGID CEILING. IH D OE FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR �yI 03 ; 1 0 0psf HALF MILE ITY BCG INC NOT BE SIDLE F1M RNY DEVIATIfIN FAONI THI6 OE6IGN: ANT FAILIARE TO BUIUD THE CROSS CaHEIXRKANCE WITH TPI: OR FABRICATING HANDLING SNIPPING INSTPolING L DANCING OF TAR DESIGN CONFORNS WITH APPLICABLE PROVISIONS k C OL LL . 10. OpSF DRWG INDUSTRIES- I.I.C. WALL OF 9 RdiTIOW DESIGN SPEC BY RFLPA) AND ITV BCD CONNECTOR PLATES ARE ARM of 20/18/160 N H/SB/IO ASTK A853 GP�IIE 40/60 fY K GRLV. STEEL. APPLY PLATES TO EACH FACE OF TRUSS AIfD ONLES9 OTHERWISE LOCATED ON %I � • j0T.LO. 55. 0 sP 0/11 LEN. 43 PANELS POSITION PER DRAWINGS IGGA-Z. RNY INSPECTION OF PLACES FOLLOWED BY (I) SHALL BE PER OF VI 1-2002 SEC. 3. R SERL ON THIS DRIVING INDICATES ACCEPTANCE OF PROFESSIONAL EN RESPONSIBILITY SOLELY FOR G *` 0 • UR.FAC. 1 .25BD19D THE TRUSS COfIPONENT DESIGN SHORN. THE SUITABILITY AND 115E ER RNSZNTrtPI 6RSM. 2Lmxc Is THE RESPONSIBILITY of THE BUILDING DESIGNER! •mot �p�: !V_ SPACING 24.0" TVP1= COMN ob:(801901 M 0 M / MOM BUILDERS "BLD 1" / CJ9 I HE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Tapp chord 2x4 SP SS 1 BoT chard 2x4 SP #2. Webs 2x4 SP #2 ' :Lt Level Return 2x4 SP #3: Lart and vertical exposed to wind pressure. Deflection meets L/240 criteria For brittle and flexible wall coveringB. Deflection meets L/360 live and L/240 total load. Fill wind load oases an this trues have a 1.33 duration Factor. 8'7"12 140 mph wind, 17.81 ft Ft From poor edge, CRT Iw-1. 00 GCpi CF/-]-0. 18 Member design based on In lieu of rigid aelli Bottom chord checked F Handling stresses not special oare.by trues damage. U-256# NAILED oH R-691# U-166# RL-555 j W=8 R-212# U-174# 0 2'4"4 11'9"10 \(i1Q:11111 maim aanrtBranaTmvTPT-2W2 FT/AT" =/Iaaa OTY- 8 TOTAL- V an RSCE 7-05 , CLOSED .bldg, nail located within 4.50 EXP �� wind TC bL-5.0 par, wind BC DL-5.0 per. th MWFRS and CSC, wind reactions based on MWFRS. use purlins to brooe BC 9 24" OC. 10.00 per non -concurrent live load.' sldered For plates. Handling of this trues reyulres uraoturer and installation contractor to prevent plate RIGHT JIG = aGn ••WHMINY•1• TRUSSES REGUINE EXTHEA` G 1N FNaRIORTING HNLLING 6H PPLM INSTF[X~ • • --/ -1 IiSTIT11fE 21BNaiM�LEE STR�ISUITE 33112,, NG TALEXANDRIA VSAFETY A. 223Igj Am TION]ISH Gv� 1 [TR , NSE 'I '•••� �w� TC' LL ps REF OF WEAICA 6300 ENTERPRISE LA NDI60N YI. 53118] �IXi SAFETY PRACTICES PRIOR TO PER , ((� \ (,` DL 15.Opsf ORTE 06-11-2009 ROOF THESE FUNCtI0N4. UNLESS OTHER4ISE INOI&ITED TOP CORD SKILL HAVE PROPERLY RTTACIIED PprE�8 6RryNpp gBggTTOM CHORD SHRLL HAVE A PROPERLY RTTACHED RIGID CEILING. Sr TRUSSES POW6 0MNTssFURNISH COPY OF THIS DESIGN TO INSTILLATION CONTRACTOR. ITY SCG INC.�_.,�A1F� y� OL 10.OPSP ORWG N0T BE RESPONSIBLE FOR MY DEVIATION FROM THIS DESIGN: ANY FRILURE TO BUILD THE iRIBSS •w . HALF MILE CDsaRNPNCE WITH TPI: OR FABRICATING HANDLING SHIPPING INSTALLING L GRACING OF TR11 C { • _ LL 10 • OpSF INDUSTRIES. LLC. DESIGN CONFIDINGITH RPPLICABLE PROVISIGNS OF k9 DIATI&e DESIGN SPEC BY RFtPFO NII • G [TV BLG CONNECTOR PLATES ARE MADE OF 2O/IB/1SGN IV HISS/10 RSTM ROS3 GRADE W60 N ` watt ciay. erEEL. f✓PMY PLATER TO EACH FACE aF AD TRIBES AINLPs� s OTHERWISE LOCATED ON TiII .' T.LO. 55.0 sf 0/R LEN. B PGSITION PER DRRVINGS IBOR-2. ANY INSPECTION OF PER d FOLLOWED BY GI] SHRLL BE PER • PANELS OF TPI 1-2002 SEC. 3.A SERL ON THIS ORRWING INDICATES ACCEPTANCE OF PROFESSIONALENai�j ♦ Q R.FRC. 1 .25 JOB #: B0190 REWMIBILITT SOLELY FOR THE TRUSS CiHMRENT DESIGN SHOWN. THE SUITABILITY AND USE (i • •i \ i CRPOIENT_FOR_HNT' BUILDING I9 THE.RESPONSIBILITT OF THE BUILDING DESIGNER, r_, _ _ _ * .- PACING 24.0" TYPE JACK ob:CB01901 M 0 M / MDM BUILDERS "BLD 1" / Al Top chord 2xS SP SS :T3, T4'2x6 SP 4#2: :TS 2x4 SP #2: Bot chord 2x8 SP SS :83, B4 2x6 SP S5: Webs 2x4 SP #3 :Ill 2x8 SP SS: ' :W2 W3 W6, WB, W9, W20, W21 2x4 SP #2: :W4 2x6 SP #2: :W10 2x4 SP #2 Oense: :W2S1 2x4 SP 95: :Rt Level Return 2x4 SP #2: •+ The maximum horizontal reaction Is 1955#.++ , (I] - plates so marked Were sized using a Fabrication Tolerance or•09 and a Rotational Tolerance oF;O degrees. 140 mph wind, 19.12 Ft neon hRSCE 7-05 CLOSED bldg, not looated within G. Ft from roof edge, CRT II, EXPgt 6, wind-TC bL-5.0 per[ wind BC OL-5.0 par. -- --(LUMBER OUR.FRC.-1.25 / PLATE OUR.FAC.-1.251 Iw-1.00 GCpI C+/-]-0.18 9 1 TC - From 209 PLF at 0.00 to 209 PLF at 4.65 Calculated horizontal def leotlon is 0.41" due to live load and 0.33" due to dead TC - From 70 PLF at 4.65 to 70 PLF at 10.27 load. i TC - From 209 PLF at 10.27 to 209 PLF at 15.04 TC - From 70 PLF at 15.04 to 70 PLF at 26.04 (B] Continuous lateral tiraoing equally spaced on member. Or 2x4 #3 or better "T" TC TC - From - From 70 73 PLF PLF. at at 26.04 32.63 to to 70 73 PLF PLF at at 32.63 45.10 brace. BOX leng9th or web (0.135-x3.5",mTn.)nalle,M member. Attached with 6" OC. 16d Box or Gun BC - From 40 PLF of 0.00 to 40 PLF at 5.17 BC - From 60 PLF at 5.17 to 60 PLF at 7.25 CC) Continuous lateral bracing equally spaced on member. Or 2x8 #3 or better "T" BC - From 40 PLF at 7.25 to 40 PLF at 7.71 brace. BOX length of web member. Attached with 16d Box or Gun _ BC - From 60 PLF at 7.71 to 60 PLF at 9.BB (0.135"x3.S",m n.)nallsj0 G" CC. BC - From 40 PLF ati 9.88 to 40 PLF at 13.88 Fog. - From 40 PLF at �13.88 to 40 PLF at 28.81 Bottom chord checked For± 1D.00 per non-conourrent live load. BC - From 40 PLF at 28.81 to 40 PLF at 42.52 BC - From 20 PLF at 42.52 to All wind load cases an this trues have a 1.33 duration factor. TC - 11B LB Cona. Load at 4.65, 10.27 TC - 410 LB Cono. Load at 6.65, 8.27 g,0' y y Member design based on both MWFRS and CBC, wind remotions based on MWFRS. 18i4N, i.1NB�t SO iSti , . OiSN i . a �« -14. 9 "4 . End verticals exposed to wind pressure. Deflection meets L/240 criteria For brittle and flexible wall coverings. •t-15'0"8 X6 17,7••' N 9.7123 - CO] Continuous lateral bracing equally spaced on member. Or lx4 #3SRB SPF-S or2X4 BXB CR] 12 1 2 5 better T" brace. 80. length of web member. Attached with 8d Box or Gu C0.113 "x2.5",min.]nai le 0 6 OC. I �.i0.25c / W20 (R) Continuous lateral bracing equally epaoed'on member. Or 2x6 #3 jOr b to "T" W ' yam, .4X4 brace. BOX length of web member. Attached with 16d or Gun I W WW 4�� [0.135"x3.5",mTn.7nalle ® s" OC. o B7 'C ) C]10 4 38XB T4 8 i(� X6 TS In lieu of rigid calling use purilns to brace C 0 4leL OC. y W (C W3 Nc� Ol X6 CX i p i Deflection meets L/360 live and L/240 total load C - T T g•;g I _ W 1 "3 •'40"^ 319 �15 C � I11 ME X4 f . I1 �e �a�v�`� r U�� �m 2X4 F Q10 4X4 2X4 6 . a B3 B4 r 42 L PIPAen - W1W -tom ®R= 99# RW=5963# U=2222# RL=1 t 148 + V'GU� 6t*�� 4,o art fbS 1'er EFT JIGl- 17.11"8 `1`�-Q„�� .T. TYP. -WAVE - ' are[av cn[>•�a�cwm[-mm srrta-za+mniioml OTY- 3 TOTAL- 3 C \ `-. ROOF TRUSSES HALF MILE R=2712# U=1282# W=8" RIGHT RIGHT REV. 8.07.00.1218.. TC LL 20.OpsF F TC DL 15.OpsF I C DL 10.OpsF C • . CF LL 10.0PSF T.LD. 55.0 sF c �•n a; g 4 tlR.FRC. PACING 1.ZS 24.0" T E= 12'7"10 S41A LEN. 43 #: 60190 Top chord 2xS SP SS :T31 T4.2x6 SP 42: :T5 2x4 SP #2: Bot chord 2x6 SP SS :B4, BS 2x6 SP SS: Webs 2x4 SP #3 :WI 2xB SP SS: '' :W2 W3 W8, W9 W10 2x6 SP #2: 'W4 2x6 SP SS: -W5, W21, W22 2x4 SP #2:' :WL1 2x4 SP #2 bense: 326 2x4 SP SS: :Rt Level Return 2x4 SP 112: --[LUMBER OUR.FRC.-1.25 / PLRTE DUR.FRC.-1.2S) TC - From 209 PLF at 0.00 to 209 PLF at 4.65 TC - From 70 PLF at 4.65to 70 PLF at 10.26 TC - From 209 PLF at 10.26 to 209 PLF at 15.03 TC - From 70 PLF at 15.03 to 70 PLF at 15.04 TC - From 70 PLF at 15.04'to 70 PLF at 26.04 TC - From 70 PLF at 26.04 to 70 PLF at 32.63 TC - From 73 PLF at 32.63 to 73 PLF at 45.10 BC - From 40 PLF at 0.00 to 40 PLF at 6.OB BC - From 60 PLF at 6.08 to 60 PLF at 8.88 BC - From 40 PLF at 8.88 to 40 PLF at 13.88 BC - From 40 PLF at 13:8B to 40 PLF at 28.81 BC - From 40 PLF at 28.81 to 40 PLF at 42.81 PLS- From 4 PLF at 42.85 to 4 PLF at 44.83 TC 1682 LB Cono. Load at 4.65, LO.26 TC - 141 LB Cone. Load at 6.65, 8.26 ID PITCH ------LUMBER------ RXL BNO CSI LOC-Ft FORCE T1 0.0 2x6 SP SS 0.00 0.24 0.24 3.33 -293 T1 0.0 2x6 SP SS 0.02 0.33 0.35 1D.54 -1307 T3 -0.3 2x6 SP #2 0.50 0.32 0.82 17.66 -6613 T4 -0.3 2x6 SP #2 0.56 0.10 0.66 30.46 -6598 TS -5.0 2x4 SP #2 0.13 0.49 0.63 - 42.S4 -1957 B1 0.0 2xB SP SS 0.00 0.37 0.37 3.33 3S B2 0.0 2xB SP SS 0.09 0.34 0.42 3.33 792 B3 0.0 2x0 SP SS 0.59 0.13 0.72 17.02 6461 B4 0.0 2x6 SP SS 0.73 0.09 0.83 23.96 6625 BS 0.0 2x6 SP SS 0.54 0.06 0.6.39 5600- Member design based on both MWFRS and C&C, a ?Ions based on WI CB) Continuous lateral bracing equally spaced o r. Or 2x8 #34r brace. BOX length of web member. Rttwit or Gun aahed C0.135"x3.5",mTn.)nnlle 0 6" OC. t ''''''"""""" ������,q,,,,, 3'5"9 Bottom chord checked for 10.00 paf non-ooncurre nd. t 0 12# -eq u�l 4 moist ed -�o r if VhI A +ro 2�0 IDS per, _JI624 17'11"8 (YP.-WBVE ®IGN n 9RNCING IN9TIM OF RHER ROOF 7RU38FS OMOKE O HALF MILE/ INDUSTRIES I. 61,1 iN 7USTRIES GPo.NSW . 9 PAY&W OFSTP11 *a+ WRRNING) CSI EXCEED am The maximum horizont 140 mph wind, 18.12 Ft Ft from roar edge, CRT IW-1.00 GCpI(4/-)-0.18 End vertloale exposed t brittle and flexlb, e we Calculated horizontal d load. (Cl Continuous lateral brace. 80. lengpth of we (0.135"x3.5"„mTn.3halls (R)-Continuous lateral brace. BOX length or we (0.135"x3.5",mTn.)naIIs In lieu of rigid oellln 1.00 C999.00) , reaction is 1953# •• ian hggt RSCE 7-05 CLOSED bldg, not located within 8.50 EXP �, wind TC 6L-5.0 per, wind BC OL-5.0 per. wind Pressure: Deflection meets L/240 criteria for coverings. 'leotlon is 0.36" due to live load and 0.29" due to dead acing equally spaced on member. Or 2x4 #3 or better "T" member. Rttached with 16d Box or Gun, 1 6" OC. acing equally spaced on member. Or 2x6 #3 or better "T" member. Rttoohed with 16d Box or Gun' G" OC- wee purlins to brooe BC # 24" CC. '468P,1��,�6Nr SO#�#.i 50#501j �Ny.N f. "�- 9' 9 "7-O..-NYy.-N l q • 9 •• 4 �4X12 CRI m N '-15'0;'8j47R85 tq@�1N',i3'36F"�- �"'�9'71�3 2X4 BX8 Q X6 0 10.25 W21 5 W W11 BX8 `� 4X4 )' C-4 X6 TS a-, T- T41 XC1 m H1315 H1315 %F1 14 5X6 HO 310 �= m B4 BS ' 4439 ! 5 "4 N Rw=8267# U=3315# RL=13 Z/-1587# W=8" R=3000# U=1419# W=8" ! Ct RIGHT RAKE - 2' #A- RIGHT JIG - REV. 8.07.00. 1218. BCRLE 12' 04C LL 2U.Upst' REF, OIL 15.0pSF DATE 06-1 OL 10.OpsF ORWG LL 10.OpsF .LD. 55.0 sF 0/8 LEN. 43 .FRC. 1.25 JOB #: BO1 ICING 24.0" TYPE COM ob:(BO190] M D M / MOM BUILDERS "BLD 1" Topp chord 2x6 SP #2 :T4 2x6•SP SS: r•T5 2x4 SP #2: got chard 2x6 SP-SS :81 2x6 SP #2: Webs 2x4 SP #2 :W1 2x8 SP SS: :W3 2x6 SP #2: :W7 2x4 SP SS: :W8 2x4 SP #2 Dense: :W11, W12, W13, W14 W18 W19, W20 2x4 SP #3: :Rt Level Return 2x4 SP 43: ulr Nailing Schedule: 10.120-x3-1,un-naI le] '.` p Top Chord: 1 Row 0 2.75' o.o. 1] 1/�T�-1fV•!+ (-�LrBo7 Chord: 1 Row 012.00" o.o. OCe Webs : 1 Row 0 4" lo.o. Use equal spacing between roue and stagger nails --:LunocK uuK.rnc.-1.40 i TC - From 430 PLF at 0.00 run;e uuM.rn6.-1.1c' to 430 PLF at 0.SS Q In each row to avoid sp Pitting. TC - From 70 PLF at 0.95 to 70 PLF at 13.96 ��` [1 Q �C `� eR} a 'm The maximum horizantcl reaction is 1955# a• TC - From 430 PLF at 13.98 to 430 PLF at 15.04 TC - From 70 PLF at 15.04 to 70 PLF at 25.88 140 mph wind 19.12 ft mean hpt RSCE 7-OS CLOSED bid not located P g' within 6.50 TC - From 70 PLF at 25.88 to 70 PLF at 32.63 I Ft From roof edge, CRT II, EX �� wind TC dL-5.0 par, wind BC OL-5.0 per. TC - From 72 PLF at 30.00 to 72 PLF at 43.25 Iw-1.00 GCpI(♦/-]-0.18 BC - From 40 PLF of 0.00 to 40 PLF at 3.25 ; BC - From 60 PLF at 3.25 to 60 PLF at 5.58 Calculated horizontal deflection is 0.41- due to live load and 0.32- due to dead BC - From 40 PLF at 5.58 to 40 PLF at 9.46 load. SC - From 60 PLF at 9.46 to 60 PLF at 11.88 SC - From 40 PLF at 11.88 to 40 PLF at 13.8E (R] Continuous lateral bracing equally spaced on member. SC - From 40 PLF at 13.88 to 40 PLF at 28.81 BC - From 40 PLF at 28.81 to 40 PLF at 42.88 Truss paused check For 20 sF additional bottom chord live load in areas with PLB- From 4 PLF at 42.88 to 4 PLF at 44.83 42--high x 24'-wide clearance. TC - 913 LB Cana Load at 0.95 2.87 12.05, 13.56 TC - 1411 LB Cana. Load at 4.65, 10.27� 91 '�11 77 rue®858#t o TC - 768 LB Conc. Load at 6.65, 8.271:t.B��tybg }rude m (I] - plates so marked were el zed us Ing a Fabr l oat l on To l eranae of OX o9r:q-1;,,..- -. m Rotational Tolerance of 0 degrees. -' �c U Member design based on both MWFRS and C8C, wind reactions based on MWFRM 44 2 "8 y 3XB 1 End verticals exposed to wind pressure. O@Rk • on meats L/240 orlterl R) 12 brittle and Flexible wall coverings. C - RII plates are 2X4 except as noted. ���,,,}}}���Fa�� In lieu of rigid ceiling use purllne to bra 24' OC. - I [R) [ 7 3 Deflection meets L/360 live and L/240 total oad O [ ) C 14 1 1 W wq� Note: Wind load gauss on this }ruse have mul atlon Foo4ors �u lth h c'I'� I W 1 highest being 1.33. 3'51'9 Ij I See Law+r wa`� S2e =JIT12 17'11•"8 TYP.-WAVE ROOF TRUSSES WAIL PANELS 1.d red for plates. Handling of this truss requires IP6'?turer and installation contractor to prevent plate m17 7- -`'- 9.7i13 - 95 22Q 5 SX6 r2't 1'�1hs' m B1 H1014 CR) 41' 4" 42' 10,"8 11458# U=4914# OTY- 2 PLI W18 W20 X10 T5 W13T4810 X4 i�o 10 R) W1 71 1 W-3'10'^ 3'9'15 X10 t 12/-1591# W=2' R=3709# U=1754# W=8" RIGHT RRKE RIGHTSJIG - 2'3"7 12'1 "15 -= 5424 REV. 8.07.00.1218.9CRLE -0.0973 TC LL 20.OpsP REF DATE 06-11-2009 TC DL 15.OpSF ORWG BC OL 10.OPSF LL 10.OpsF 0/19 LEN. 43 ZDT.LO. 55.0 SF Li(1R _FRC_ 1.25 JOB #: B0190 9 2 O j 3 i O� 9 mmHy•�i-I N mi O .-riD mm �? 3 Sg c���i0000no�'m G: tg C g p .��'9 [w TaT TaT3T aT aT aTPn mRa- O a b E' 2533333333� yo�``ya m Ny[ 9-� ^ l_ �n mAg�oo�ocy�041v8 yy �CC•3 m ` < NP1 •'» mpm r99999 r9 r99 m -g9i9t F A "' yO �+ _� �/1 • /� a �m am 18 �ITTTTT TTa ��LWNN /�/�•� ✓ � � `Fi asp( � 6 oQ �0 4 O=, s•1�N������D v'a Ems 3 �m O 1 n •� mg. m a (nR nm %. NAomNN u i 4mq Rd 9 qb g ;a_�s8_0Y!00-0-�] � m� o IV m mG oS `•1y3 mC OOmOOmmm NOW Co N g� $grn rai?mm@Vo �. m b °5�'�Ig{ $ aUig� S ii /#� = 0 ®S m7a �� bWRR:mi NNF N (/) 9B Hu 9a H �S= i � 7 R �' g! N9 iN gm.B m IS 9 pp g r gSSgpGp qa gg �mY [TgCS� /��/> A 15, g Y Hip. O �•0 ci z m rn ac• $ �. r +{+{1 X XO +{cp C!R �%pubp� r� Im m X <1ea<• $ S� g S S� g 00 ,0 • _ mm �•c 'm Iy •90 0,� ,•ate o �; s 6•,��-_$ -. IIi�NQINE�� ��+m m m mS �S $g a N m +t N N o o m D 9 r p O r< I O % A N R O O o S r F � Z n c rr,.v,c �' u'i $R �• 0 A N o N m T} n S O O O N (P P O •0vav-COD vCW m I� m X I T 1]] OR O 37 D ffl uifA A ANYR�1 G N &ll1 0,%• 1 5 m 00 D _ T OT - -- - - —C - - - tp. m- _ f T. _ Dom- I� A $ $ m Z m'I ~` $ co o— m w4r S 3 3 m p m m nog �m O Q 8 m , =1 oil, 1.1at8 fl., twi, Top chord 2x4 SP #2:T2, T3 20 SP fn: OLd�O Sol chord 2x6 SP SS :B12a6 SP #2: , bldg, not located wthin 6.50 It from roof edge, CAT II, ECP C. wind TO L . I . Webs 20 SP #3:W 1, W17 20 SP #2 Demo: End veNcaLs net exposed to vAnd preSbure. :W6, W7, Wit, W122z4 SP#2 :Lt Level Return 20 SP #2:Rt Level Return 2x4 SP #Z (A) Contlnuous lateral bracing squatty sDaaxl on member. Or tz4 f{35RB SPFS or better T brace. 80%lengtth of web SPECIAL LOADS member. Attached with 8d Box or Gun (0.113'x2.5',mLn.)na1ls ® 6' OC. -(LUMBER DURYAC =1.25 / PLATE DUR.FAC.=1.25) (B) Cominuars lateral bracing equally spaced an member. Or 2x6 #3 or better'T' bmce. 80%length of web member. Attached TC - From at 73 PLFat-222 to 73 PLF at 9.59 with 16d Box or Gun(0.135'x3.5',m1m)nalIs 06' 00. TC-Fran TC-Fran 70 PLF at 9.59 to 70 PLF at 22.94 to 70 PLF at 22.94 70 PLF at 29.69 In lieu of rigid miring tee purrns to brace SO 024' OC. TC-From 73 PLF al 29.69 to 73 PLF at 42.16 BC - From 40 PLF at 0.00 to 40 PLF at 14.00 Deflection meets 1.1360 live and L/240 Hal load. BC - Fran 40 PLFat 14.00 to 40 PLF at 25.88 BC - From 40 PLF at 25.88 to 40 PLF at 39.88 All o wntl load cases on Oils truss have A 1.33 duration factor. PLS- From F 4 PLF a14.96 to 4PLF 3992 to 4 PLF at -0.04 4PLF At 4190 - - PL& ran TC - 250 LB Cana. Load at 16.94, 22.94 •• The maximum horizontal reaction Is 1010#" Member design based at both MWFRS and CBC, Wind reactions based on MWFRS. Calculated horizontal deflection Is 0.27' duo to Rve load and 0.19' due to dead lead. wM Continuous8d BorGhm lateral bracing equally min) spaced an member. ber. Or 2x4 93 or better T brace. 80% length of web member. Attached (D) Cahtinucus lateral bossing equally spaced on member. Or gall #3 or better T brace. 80%lergth of web member. ABecled- 161 WM 16tl Box or Gut (0.135'x3.5',mh)Inails ® 6' CC. c {2' 97-13/16' Bottom chord checked for 10.00 psi non -concurrent hive load 1. Harding stresses not considered for plates. Handling of thLs truss requires special cam by u-0 chimer and i- axdmaorta prevent plate damage. q 5X6 5X6 o;IX4 (B) -1 S� e �p�� Orr �dCa7wN J rill A�r W hMa or 4e , W ram Q6r 1 `Bf 250# -1 250% + 6' 15'11-1/4' I $ 19'6' 97-13/16' - S 6'9.1/16' 4'10- 411' d ~m 56 4X4 ilk . BX10R� syr N N R=2636# U=1225# W=6' SEO= 11347 T17 ,•-,,(V�.' ��1$Ew�9,,,��iy oesax am-racmorewnnmurm+*-m+texn^Ira OTY=4 TOTAL--4 '� • 5 •'•* • REV. 8.07.00.1218.13 SCALE=0.1040 YPT17 ARNOl01"R OFO OTEB ONT 100 WI 0 J TCLL 20.Dp6f REF '9MpoRTAM-FUFLNItNTHISORAWINOTOALLCON1MOrOR01NCW01NOTHB INSTALLERS, E1 �I *"�"eph• ^ "°" se°gp"'m"etl0i°" A°'"„�,,,r F� W TC DL 15.OpSf DATE 06-g82009 mo�e.s•u�aean r,.vn .#Wm,.un.Nmh•uwtub ROOF caeat.amlmo.^•^wre^�"ro^°`wawmh.,w®r.avow ��• •W 10.0 Sf urmrmamrwv.wmomwa..mcm#m.lmawvbe+w>,c.eemonaoe "A TRUS56 wl,....pq,me•�•en m�.as laim,w,•hawmm�•uwnremaaa.,m � d�F � Z BC DL P DRWG w •chat meat �.W m�,e,e >a•mwm. NWb�m anm 10.0 Sf HALF MILE -.e°n,bommTmumm.�mn,vnh»uwarc•am�.v. i i �(? BC LL P metrbeo�q�1(a4ZbYmgeEnW{mOfu /' O=• nw eaRaum.�acnercwinbmWvsabnm,mmwnweama I i INDUSTRIES LLC. unmwr,eomm..emwn.mu+svrn,•>br.mywgoa \. 2� TOT.LD. 55.Opsf O/A LEN. 40 W LL ° ahnerg>�rnw!aane.rnr�a�+. �ap�amr � 9� :. F L 0�'�V��\, DUR.FAC. 1.25 JOB #: B0190 )b:(BO190) M D M / MDM BUILDERS'BLD 1' / HJ9 Top chord 2x4 SP #2 Bd chord 2x6 SP #2 :B2 2x6 SP SS: Webs 2x4 SP#2:W32x4 SP #3: :Lt Level Return 2x4 SP #3: (Ml) _ (J) Hanger net calculated {2)2x6 SP #2 supporting member. In lieu of rigid ceiling use purlins to brace BC ® 24' OC. Hip)ack supports 9-11-8 setback lads. Jades up to T have no webs. Luger jacks supported to BC. Handfug stresses not considered for plates. Handing of Me toss requires special care by toss manufacturer and installation contractor to prevent plate damage. 133# t - 16'10-7/8' 14'0-15/16' 2'9.3/4' 6'8-7/16' 68.1/2' 140 mph wind, 18.13 It mean hgt ASCE 7-05, CLOSED Bldg, Located anywhere in root CAT 111 EXP C, wind TC DL=5.0 psf, wind BC DLd.O psi. Iw=1.00 GCpl(M,)=0.la Wind reactions based an MWFRS pressures: , End verticals not exposed to wind preMUM. (A) Continuous lateral bracing equally paced on member. Or 2x4 #3 or beder'T' brace. 80% length ct web member. Attached with 16d Box or Gun (0.135'x3.5',min. naffs ® W OC. Deflection meets U360 five and L240 total load. All wind bad cases on this toss have )11.33 duration factor. I 1 12 3.54 p SXB ii 5X6 W3 A) 1� 1 4X4 I 8X8 B2 2X4 � 14'0-15/16' H0308(R) 3X0 a µ�6'8.1/4' �6'10' S 14'0-15/16' =1198# U=686# W=10-9/16' R=1744# U=852# H=H1 NJ hWAgTF9.,� �i� TAG= T15 ,�r�NSE +., : •41 0 REV. 8.07.00.1218.13 SEQ= 11454 SCALE=0.2166 PLT. TYP:WAVE osson csnrecmvrccw,wmxvrmm.an4roV,am QTY=4 TOTAL=4 -WARN0I01"READANO FO NOTES ON IS DRA I O "IWORTANT"R#WISHT#S ORAWINOTOALLCONTRAOTORS INOWDINO TfE INSTALLERS. Tn�••Nm]mnnbtMbq •iP4b�V•tlmrlR lYbbN �V 5ft :�{. Q w TCLL 2O.Op9f REF ao.roire.eemaacs r.s` s.a. w•..m.ym.iaw,caa� , .ro , TC DL 15.OpSf DATE OGOB2008 ROOF sl�TRUSSES a+�.+•mw�+oe®�i�..�bu wmm oro'mer�•vmrm++aw umv mm ue�w, mo 4ve e.a mw mnM ays>+ef euv.Evd tivCBg W Ewn tivE weiw..n,m.m.�..rr+o,�•#�ro.e•°mm+mm.�+°aw � • �� W �.I ��' :Z BC DL 10.OPSf DRWG w re,.m rsmmbe,•. ..w•ax m>eranms�m. #Rb Wbab®911Y a�..,e,o.+ub.i.m+.meo,rouwo.m.i.+b.,�maumw IWYb ,•]+ibrm.ewpmtbmma mvo+myouo`cm+manmrbnae,memmnmm+y - i �'• IT BC LL ro (? Q 10.0P Sf �_ HALF MILE ' 0/A LEN. 140015 INOUSTRIEB LLC. •� �b bmbm4nwe.1mN154'rFl,.>mrbmp+�Ps.°mfaam Aim.r.•+VvaovPPl+arrYrobsrmG�•>aPU�b.I 'Y✓'aoo°wro"M'r'°"°°°"ra^ 1"'bmratr"°'roera°°r° �I� A #� • •�7 �i 'P\� •�4�,�� •' •••F::.�.'• • \• \� TOT.LD. DUR.FAC. 55.OpSf 1.25 WALL PANELS JOB #: B0190 amnaivm...v.mo.#mrodropmao•wwANevmn.w aP O SPACING 24.0° TYPE HIP JACK Job:(BO196) M D M / MDM BUILDERS'BLD 1' / THIS DWG. PREPARED BY THE ALPINEJOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Top chord ZA SP #2 ' Bat chord 2x4 SP #2 Webs 2x4 SP #2:W2, INS 2x4 SP 0: :Lt Level Return 2a4 SP #3:' In 6eu of dgid ceiling use purlins to brace SC ® 24. OC. Deflection meets LiJ60 We and 1-240 total load. All wind load cases on this mss have a 1.33 duration factor I •�—N d 41-1/2'-48-1/2' m 9, 47-3/4' 4'1U-1/4- Lv R= U=168# RL--3W-124# Wes' R=54O# U=403# 140 mph wsM, 16.12 ft mean hgL ASCE 7.05, CLOSED bldg. not located within 4.60 ft from roof edge, CAT II, EXP C. wind TO DLd.O Did, wlrrd SC DL=5.0 Pet. Ivr-1:I00 GCpi(4/-)=0.18 , Member design based on both MWFRS and C&C, wind reactions based on MWFRS. , End verticals not exposed to wind Pressure. Bottom lard checked for 10.00 Pat ncrn ouaent five load. Hens firg stresses not considered for plates. Handling of this tress mquires special care by truss m adorer and Iretataflon contractor to prevent plate damage. !I 1 l ��, •••i IF ��I ��i� TAG= T11 (��••'•�iSE'+9 SEO= 11335 PLT. TYP.WAVE OTY=20 TOTAL-- 20 .� : •* • REV. 8.07.00.1218.13 SCALE=0.2588 INGI- REM ANDFO - NOTES ON THIGO GI- . • 'nMFOffTANr- FURMIIHTHIS DRAWING TOALLOON11AOf01111 INOLUDINGTHE INRALLERD. '(V�r •. (j •Q. TC ILL. 20.OPSf REF! DATE 06-0&2009 ROOF T ,yLa�mel•bWi1q M•FAYyp�q•�A�R� •b WY11N�ybN �m p�M'd�q�••1.1dduvMd••sd�•IPM•Yna•YTpb�••t�e� ' 1'+� W TC DL 15.OPSf DRWG TRUSSES ub•,mm.da ran..ri.,.mwnmueam.sa..+c.�aemoaba Oi drm,.•pmeq.v�•eMau•b �,•••m,arvi..+•rm,.mr,awm i \JJ��F �z BC DL 10.0PSf yml l,q• rypypfBCaNypa9. eldelam(d6a••{m d[eb�l,•u d bm.b mwndbwvemnrdxom,u•nwem.•r ad.,b Ibd•mddmndAbs dw••� • is i '� I is �� BC LL 10.0 Sf P . ' _ HALF MILE INDUSTRIES LLC. mV �m.w•fwbxdmmrm,amv�vewb•emxm,Mnwd�o Armxra.novawl.awvne.+nwa.m••dFdmr A. Woo mr.•uv.di.drrm.## �• I • ao4 L • 7/ �i Q• Jr• \�•!�♦ . F L .• ••.•• •••�• V �� P TOT.LD. DUR.FAC. 55.0PSf 1.25 O/A LEN. 10 WAIL PANES PANES JOB#: B0190 wev.wmmmvwAvw•d,anrw.b•s.o.bc,�_ �Ii •• _E.SS�ON d� SPACING 24.0' TYPE EJACK ft(B0190) M D M / MDM BUILDERS'BLD V Top Chord 2X4 SP #2 Bot chord 2X4 SP #2 Webs 2X4 SP #3 Roof overhang aupports 2.00 psf soffd load. In Use of dgid co0ng use purare to brace SC 0 2V OC. DeOeotion meets U360 We and I240 total load ..... BEARING ANALOG MODIFIEDI ••••. 3X4[B1) THIS DWG. PREPARED •• The matumum horizontal n Member design based on,both MW F Bottom chord checked for 10.00 Pat Handling stresses not considered to contractor to prevent plate damage. All wind load cases an this tmss hav — 10-1/2' — —2'5.3/8' Hi FlUKTIZ# Rh=411# RL=282/-232# NAILED .k - -I-ze 3'S-5/8' i 23.3/8' ~ 3'55/8' R=111# U=79# Rh=411# n811- 2# NAILED 11#•• 1 I 7.05, CLOSED bldg, Located anywhere In roof, CAT II, EXP C, wind TC OL.S.0 psf, 0.18 and C&C, wind reactions based on MWFRS. -concurrent Ova load tax Handling of the Russ requires spacial care by mess manufacturer and Installation 1.33 duration factor. S r�� -Y9Af i 9, \\(4� t••••$C'•y�F �O� PL .TYP. WIAVE oesox am normwrnaamnmr�oxla want OTY= 2 TOTAL=2 �� i • vN +�•• * ,win REV. 8.07.00.1218.13 SCALE =0.9745 .IMPORTANI"-WAFININFU UHTHIC OCINWI OTOALLCC TTRAM W ALL NOTEII ON T11111INCUIMINO IIEINSTALERIL � W A 5\ ' L'�. TC LL 20.Opsf REF mm.mm.mmaeavlaa•awn TC DL 15.0psf DATE 080!>-2009 ROOF mm+aemw>am+o.vn.am• •+w•m• mrar,a+ u.\ t PV`\• 10.Opsf DRWG TRUSSES •,.rro...nwy��.aMt.•a wmeem....o...,ner+,.ma+a.e• ro :z BC DL pmrtmn avgmvuup•Bcv sswatervmangpunn /.wMprm•b.aem '0 HALF MILE' " a.'�"mn0 ra ui°0"mw e�wm'1°°.+°Oe"'�'� • i ��''I �� (? � BC LL 10.Opsf nwaa•B kvo•mwrme. mr.vvxe•,trn,ms••+n t O' 55.0 Sf OlA LEN. 30617 INDUSTRIES LLC, rr.ed comma,mmu•..o..emu+s' '+"'•aroa�oo+tgam.mrm, �jo A \ .e ��� TOT.LD. p NnLf. Ararom+aam.wrarrero+io-nrw.oaw.m+' ` • p L �P: �(i �� PANELS •rrneaRnrgsymaarytwn V.•rrgnararooe•o •�"7 ••.••••••• ;• V �� DUR.FAC. 1.25 JOB'#: B0190 vaamtmrmbaoaw y�h•""��e°= ,��b SPACING 24.04 TYPE JACK __ ESSIO ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT I Top chord 20 SP 02 Bat chard 20 SP #2 Webs 2t4 SP#3 , Root me" supports 2.00 Pat solid load. In Geu of rigid calling use purfins to brace BC ® 24' OC. Deflection meets L= Bye and 1-240 total load. All wind lead rases on this toss have a 1.33 duration factor. u Negative reaction(s) of -19U MAX. - ' 140 mph wind, 2&85 N mean hgt A wmd BC DL=5.0 Pat. Iw=1.(0 GCpil Member design based on both MINI Bottom chord checked for 10.00 psi Harding stresses not considered to coMrectorto preverd plate damage. — 9-7/16' — 34-9/16' . — 2'5-3l8' 1'ORW94—Rw=98# U=1289 NAILED ;as below) from a mr'rNW loadcase regwep uplift comgceon. , 'E 7-05, CLOSED Wit, Located anywhere in real, CAT 11, EXP C, wind TC DLa5.0 Pat, )=0.18 I IS and CBC, wind reactions based on MW FTiS. Attar rd rive load. Hates. Handling of this truss requires special care by truss mandacturer and installation d I I 5 � 3X6 i t z 2'3-3/8' 1'0.1/4' - ~ 3X6 a 315-5/8° R=575# U--f' 68# RL=QW=1'2' AG PYT �o. . "gE'F'9wo 4 •• I•+ ♦y �N '1 SEO= 11664 PWAVE DEDaxramseGb7GawnAaIDFrmM19%lD•Y+OPI OTY=2 TOTAL=2 ,%� 4 'I ♦ REV. 8.07.00.1218.13 SCALE=1.0379 AR GI'RNAO AND FOLLOW OTEO ON THIS ORAWI GI 'IMPORTANT'FURNISH THIN WCWOINGTNE INSTALLER& . : � V (•V1 :,�O•yWW. TOLL 20.OPSf .REFIT DATE o}og-loosTC A�"ymmWa••i 'rw+mrfrdql¢v.cu�m.r r.uwmcrlmawa.,am. DL 15.Opsf RODP TRUSSES cmammv..�ns+.OedM.nn.Wwre•aI.oN+sm.G�romTTvmmO..•+Ab•.LrL.ev+.OvO.mMaar.eMmemDoTm�.O.Ren# n�m.n.dmm..n.m."rNmi•n.�caiv,na'aac�.ceraenaeao wr+.eaaormrac• rmnalernelaogw NWoas•vnio dam.iao�cw.�m..iemr.se.Dm.umiueee..m. adwea.+prmtx�v.oaddm.e.•.. • • ♦ * �.wcdm •` T' '(Fi (?: BC DL BC LL 10.0psf 10.Opsf DRWG . HALF MILE O/A LEN. 3oan INDUSTRIES LLC. u...a�numwn .mi �n°�.i m�'.m�"y'�pd a�wau"'°m, ArmdY'�mnwoa=wtPp••av6m..yrYarmo.odPd..oa .+a.sa.ea•>.aat•mrn+o"TM•w�2'•um.r+m+a vymm.sr.iwmaar.auaowvwAxsumteea wm.mumomvre.wrw.+dmoa.da,ea..eue� i • I♦ A • I� I/�. I S M ♦ • % :. pL pA,:.Qi�� •..� • •t �� .... , P ��' ESS�O� TOT.LD. OUR.FAC. SPACING 55.0 Sf P 1.25 24.0' WALL Pq� JOB,#: B0190 TYPE JACK Job: BO190 M D M / MDM BUILDERS'BLD 1' / Top chord 20 SP ®2 Bot chord 2c4 SP Y2 Webs 2x4 SP W3 Roof ovedsrg supports 2.00 Pat soffit load. In Eau of dgd calling use purlirs to brace SC ® 24' OC. DeOecUon meets LiM Eve end 1240 total load All wind load rases on this truss have a 1.33 duration factor. 27-1/8' 12 5 p 3X4 m d8X4(B1) li Li 23.5/8' t �2'3-3/8' 1'9-1/8'� 7'0.15/16' TAG = T3 PLT. TYP: Wr ROOP TRUSSES THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT 1 140 mph vM4 24.62 It mean hgb, ASCE 74)5, CLOSED bldg, not located within 4.50 it from mot edge. CAT 11, EXP C, YAM TC DLd.O pal. wind BC DI d.O pal. 1w=1.00 GCpi(a/-)=0.18 Member design based on both MWFRS and C6C, wind reactions based on MWFRS. All plates are 2X4 except as noted 'I Bottom chard checked for 10.00 pat roRcorcnmem two load. Handing stresses not considered for p1; es. Handling of this buss regNma special care by muss m daidumr and Installation com actor to prevent plate damage. 4'S-13/16' R=133# U=183# NAILED 10 io U �6 deals )pH U=100pM RL--58/-801 0 * 10— REV. 8.07.00.1218.13 IM TC LL 20.Opsf WTC DL 15.Opsf Z BC DL 1 O.Opsf BIGLL 10.Opsf Z�•` I`% TOT.LD. 55.Opsf DUR.FAC. 1.25 11588 =0.5748 O/A LEN. 7 JOB k: B0190 oil Db:(BO190) M D M / MDM BUILDERS'BLD 1' / Top chord 2x4 SIP #2 ' Sol chord 2x4 SP #2 Webs 2x4 SP #3 Root overhang supports 2.00 par Sofrif load 01 no supports 7-0.0jecks W2 panel TO and no and van. Deflection meets U360 Me and 1-/240 total load. Al wind load cases on 0tls tmas have a 1.33 Jura lon factor. 3 cli, 4o WXeu 140 mph vAnd, 24.62It mean hgt, M wind BC DI =5.0 psf. Iw=1.00 GCpi(i Wind reactions based on MWFRS pr In lieu of rigid celing use puriins to br Left side lacks have 7-0-0 setback w 0.1-6 overhang. Right side lacks hev Handling stresses net considered for contractor to prevent plate damage. �-v vSs -e 4-iss k ` 1 7'0.15/16' . 87-3/8' ' - --3'4.5/8° 3'8-5/16' 4'3-11/16' 4'3-11/16° 7-05, CLOSED bldg, Locatedanywhere land, CAT II. EXP C, wind TC DL=5.0 pd. 0.18 nee. BC CI 24' OC. -3-10 cam and 0-" me". Endjacks have 7.0.0 setback with 2-3-10 cam and D-0 setback with 2-3.10 cam and 0-1-6 overhang. ea. Handling of this toss requires special care bytnlss manufacturer and installation .c. , RBI O �h l ►t� (oc koHs v 0 4ev r�S 7'0.16/16' or -OL s!a r 0. c II II; II II n n u n •� 32-1/8° 2X4 2'"14' ++� 2' 8 8 e 2' 2' 2"— 2'0-3/44 2 4 37-1/8' — 3'0-7/8' 3'11-13/16° 9-5/16° 3'6-9/16' 3'6-13/16- 35-7/8° 22'9-1/4' 7' + 8'9-1/4' 154 .i 7 I -- R=860# U=215#'W=1-1/20 t6o# 1-1/2° R=662# U=20"I W=1-1/2° R=58# W=1-1/2° - R=118# W=1.1/2' R=200# U=44# W=1-1/2° R=1682# 0=590# W= R=48# RW IfW=1-1/2' '1 R=14110 U=402# W=1-1/2' O�II1111� f WARwF9•,�� TAG= T2 �.�� �/•'rfiNS� ,) •�•. ,�i REV. 8.07.00.1218.13 SCALE 11 01 PLT. TYP: WAVE ssswxaar.recmmncpwrwaxo.rmr�rtincw4el OTY= 2 TOTAL-- 2 . i 333 ARNI O-REAO AND FOLLOW NOTES ON THIS ORAW111131 'q4j\ i • TC LL 20.0p6f REF! T.-IMpORrAM- FURNIOH THIS ORAWINO TOALL CONTRAMRS INCWOINO THE INOTAMM. =`W�V 5 •a.. m a.•..Y..s:iw•�awd WI OOl: a� Be LL 10Apsf DRw rcw.obm.•.aemaecat ctlw.�sm wmtlm�wT.IWwrrw lP.rtry F'T CDL 15.0 6f DATE 06-09.2009 b !Yon hVffiTs ROOF. Be • • G TRV35E5 mmio..PP.hvvdm Pab rmOn°YmblmvYYbWmwYYPrY • DL p byrnpOhVtlryryb°bMpl L9Y.OifBJ.BlPeletl./{py{hllbvli� tlPmbbe#aT Wtl,b°..dmO.HYMWSuwtltlaltOYPb. R°I b IW°Sbtl.tl.Cnb°P� HALF MILE °^•otlo�s °wm°.,.v..nrP.v.xmumnw.atlbp INDUSTRIES I.I.C. bo°°•m� vv.wbbloaP.+...rnµsvmtPiPwimu wpywimmm �j, A �� \� ��� TOT.LD. 55.0p6f O/A LEN. 220706 WAIL ArlmWm,4Cam�i4a�ebJMOldYblmVbudPa�.� t FLOP• �fi \� PANRIS.yr.Ao�wxxrov.twklnwepieP°.lnmsa.bi.os•.An '•j"/ •'•..... ••6•� \� DUR.FAC. 1.25 JOBIi #: 80190 a.nunrm.e.•.rtio�.Wl""°.tl�,'a°°tl,.e.m°.Pc ..I,�,I F`SSI�N i�•`, SPACING 24.0' TYPE HIPS Job: BO190 M D M / MOM BUILDERS'BLD 1' / CJ1A Top chord 2c4 SP 02 Bol chord 2x4 SP #2 Roof overhang supportS 2.00 psf Soffit load. Bonan chord checked for 10.00 psf non carlcurrent live load. Harmfng Stresses not considered for plates. Handfirg of INS tm a, mgtdms special care bytnas manufacturer and Installation contractor to prevent plate damage. All wind load cases on this lmss have a 1.33 duration factor. 1'5-WW` 2" 1'3-5/8' 1'5.5/8' TAG = T30 PLT.TYP.-WAVE ROOF TRUSSES HALF MILE IUSTRIES L THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT 140 mph wmd, 23.451t mean hgy ASOE 7-05. CLOSED bldg, Located anywhere in rpof, CAT 11, EX C, wind TO DL=5.0 PSI, wind BC DL=5.0 Pat. Iw=1.00 GCpl(+/-)=O.18 Member design based on both MWFRS and CBC, wind reactions based on MW FRS. In Eau of dgid ceiling we pudirs to brace SO ® 24. OC. 'Deflection meets LM Eve and L240 total load. . R=101# U=81# Rh=135# RL=94/-72# NAILED R=47# RW=69# U-4# Rh— 135# OTY= 8 s 4L REV. 8.07.00.1218.13 aaw = L m.o SCALE=1.8553 TC LL TC DL BC DL BC LL TOT.LD. 20.Opsf 15.Opsf 10.Opsf 10.Opsf 55.Opsf REF DATE osge-2D DRWG O/A LEN. 10411 DUR.FAC. 1.25 JOB #: B0190 SPACING 24.0' TYPE JACK '/A5G Top lord 2x4 SP #2:T2, T3 2x6 SP 12 Bat lord 24 SP 82:82 2a6 SP SS: Webs 2c4 SP 03:W4, W5, W7, We, W1020 SP 42 :Lt Level Return 2z4 SP M3::Rt Level Return 2A SP e3: 140 mph wind, 17.99 ft mean hgt, ASCE 7-05, CLOSED bldg, Located anywhere In roof, CAT II, E%P C, vA d TO DLd.O psf, wind BC DI =5.0 psf. 1w 1.00 GCpi(+F-)-0.18 End vemcals not exposed to wind pressure. In ties of rigid cePmg use purlins to brace BC ® 24- OC. Left side lacks have 10.60 setback with 0.0-0 cam and 2.2-11 overhang. End lacks have 10.0.0 setback with 0.0.0 cam and 2.2.11 overhang. Right side lacks have 10.0.0 setback with 0-0-0 cam and 2-2-11 overhang. Ati wind load cases an this toss have a 1.33 duration factor. = TIC YP: WAVE ROOF TRUSSES HALF MILE INDUSTRIES LL FKALL PANEIS Trusses Nailing Schedule: (0.120•z3 _Gun_nWIs) Top Chard: 1 Row @12.00' o.c. 1 Bat Chord:1 Raw ® 6.25' mc. Webs :1 Row ® 4' o.c. Use equal spacing between rows and stagger nails In each row to avoid splitting. Wind reactions based on MWFRS pressures. (A) Continuous lateral bracing equally spaced an member 81 hip supports 10-0-0 lacks to BC. Deflection meats L IM live and 1-1240Intel load. stresses 9'4.13/i6' 20' "-11/16" . 4'85/16' d, 67-7/16' 67-7/16' 6'9-3/16' 12 5 p Handling of this truss requires speclal care by toss manufacturer and Installation 94-13/16' +' T 4'8-5/16' — 4'9-11/16' nuo ill 13'8.1/2' 13'8-1/2' -� 2' ICA 2 ao' I 9'11-1/4' 20' 11 911-1/40 16030 160 R=ssnrt u=26e2n w=6• � R=59774 u=zsezx r -6• PLIES= A 11437 4L 'ap REV. 8.07.00.1218.13 SCAALE 3 (_. TO LL , 20.0psf REF DATE D6-0e-2oo9 W TC DL 15.0psf zBC DL 10.0psf DRWG BC LL 10.Opsf O/A LEN. 40 ToT.LD. 55.Opsf ,�� , 5 JOB . BO SPACING 24.00 TYPE HIPS 'ob:(BO190) M D M/MDM BUILDERS'BLD 1°/A4 Top chord 2X4 SP 92:T2, T32x6 SP #2: ' Bot chord 2x8 SP SS , Webs 20 SP #3:W 1, W16 20 SP 02 Dense: :WB, W7. W10, W11 2X4 SP #2 :Lt Level Return 2x4 SP 03::Ftt Level Return 2x4 SP #3: Calculated horizontal deflection Is 0.20- due to live load and 0.17- due to dead load. (a) iC n Boy w Gun Moral bracing y spaced d on member. Or 2x4 #3 or better T brace. BWo length of web member. Attached witIn flout of rigid ceiling use pudirs to brace ISO ® 24' OC. Deflection meets U360 We and 1-/240 total load Ali wind load cases on this tons have a 1.33 duration factor. in 1 THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT 140 mph wind, 18.05 G mean hgL ASCE 7-05, CLOSED bldg, not located within ESP ft from rogf edge, CAT -II, EXP C. Wnd TO DLs5.0 Psi, wind BC DLd.O Pat. 1w 1:00 GCPI(+/-)=0.18 Member design based on bath NIW FRS and CSC, wmd reactions based on MWFAS. ' End veNcals not exposed to wind pressure. (C) Continuous lateral bracing equally sppaced on member. Or 1x4 #3SRB SPF-S or better'T' brace. 80% length of web member. Attached with Od Box or Gun (0.113')2.5',mIrQnaIIs ® 6' CC. (A) Cardin. lateral bracing eq. spaced on member. Or 2x6 #3 or better T brace. 80%length of web member. Attached Bottom chord checked for 10.00 pat ndn-concurrem We load. Handling stresses not considered for plates. Handling of this toss regulres special care by truss manufacturer and installation contractor to provers plate damage. i 97-13/16' 0 19161I 97.13/16° r«r i4 4'11' 4V-W to 6'6' 6'6' 65-15/16' ' 4:10' 4'11' 12 4X4 411 \\ 5 L�— l/� 12 nps 4X4(R) ..,..4 440, 3 3'9-3/4 4'111-114' — 5'11-1/4' 3'9.3/4' 511-1/2°4'11°—� 2 2' R=2385# U=1080# RL=964/-989# W=8' R=2386# U=1083# W=8' 'I Vj qq I 0,,`uugr 'o �fi��•• SE'~'••. SEO= 11366 PLAT.. T1'P.TWAVE oevonamseemmcawm aux nmr-mwe*mam 26 OTY=2 TOTAL=2 ♦` d 0 ' .1 yi REV. 8.07.00.1218.13 SCALE=0.1658 ^WAR 1 GI"RPJIOANDPOULOW ALL NOTESO THIBDRA I GI \ " �. TCLL 20.0psf REF "ILIPORTANT"FUIINIBN TWO DRAWING TOALLOON11=0IY INCWDOIG THE INBTALLERIL Id E! a •{L m^•^••�•mF0"'•o °o W 15.Opsf DATE O6-0F2009 me.m+b.mmaecelamacmn..e a .,,•em.wm.ewnrwmnr ��� O W TC DL ROOF .m~mabmynab•.r.nn.cmu ucu. ua."'~'°<°'°^"'...c�Maw'~"'°""n.'.r°'°"m: mm.°�°° �' :Z BC DL 10.Opsf DIawG sl�TRUSSES whv..aw.yaee.el/g�f+roh®em•eabboem,...amoh,emruam �� a wMwYSYyY6+Y1W&S'Iv�W a;ervef4~NYY. /fq'Wlnbviilm `�1� HALF MILE4t.h\T �v �i /��� BCLL 10.Opsf Ptivbpglp1l�Sb WY~[dd p8'bC IIW fmMbembY6W,Yb,.p.WYb�I6.tll,IM,.bUu•Y INDUSTRIES LLD. b..• egu'..ran.bma�.n�+r++surr++.>e.e..so.wuab�•h �i� A I \O.' ��� 7oT.LD. 55.Opsf O/A LEN. 40 •rmtYl.+Vnm.�t4..ab�+nYmr.mpYotlPQ.@�V • • ��♦ PANELS m�TM •:� F L O�.•' ♦♦ DUR.FAC. 1.25 JOB';#: B0190 ^ Ivbnawnnn ,o nwhp�w ,�i�O N- SPEC ESR�O, .♦ SPACING 24.0° TYPE �.;,: .�� :. �, ._ �fi Job: 80190 M D M / MDM BUILDERS'BLD 1' / Bt Top chord 2x4 So 92 Sol dsrd 2x4 SP 92 ' Webs 2x4 SP#3 Roof werhang supports 200loaf soffit load. Bosom chord dw:ked for 10.00lost rw. rrem Me load Handling success not considered for plates. Harw'irg of this toss mgidms special care by MJSS mamdachoer and haul atim Comrect0rt0 pm mrd plate damage. I ro n m -v 3X4(B1) 7 6,01w - 1 TAG = T7 PLT. TYP: WAVE ROOF TRUSSES HALF MIL THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MF 140 mph wind, 25.04 If mean hilt, ASCE 7-05, CLOSED bldg. not located within 4.50 If from DL.a5.0 psf, wind SO DL=5.0 psi.1w-1,00 GCpl(H-)-O.18 Member design based on both MW FRS and CBC, wind reactions based on MWFRS. ' In Heu of rigid calling Ise puffins to bm� BC ® 24' OC. Deflection mees U360live and 1l240 tots) load I All wind load cases w this truss have 91.33 dma m factor. 9'0.15/16' 47-3/8' 9'0.15/16' 3-4-5/8' 5'8-5/16' 4-73/8' t 53.5/16' 3'9-5/8' {%3 C(( �Lf' O.C. [64 �eV"7 aC�l O {�LEafS A 0 5X8 32-1/8' 2X4 2'03/4' -• — 2' � 2' 3X 3'0.7/8' 5'10-1/16' �^ R=696# U=498# RL=152/-152# W=1-1/2' R=55# Rw=63# U=25# W=1-1/2' R=111# U=7# W=1 R-410# 2' ro H03082 2';� 2'03/4°3X4 37-1/8' q-- 3 5'6-i13/16° 3'5-7/8'— -1/R=295# U=253# W=1-1/2' j R=141# U--19#'W=1-1/2' R--15if Rw=77# U=38# W=1-1/2' 0,1[� 1 R=788# Ud43# W=1-1/2' -`-85# W=1-1/2' '� R CAT It. EXP C. wind TC ,,�.•'' SE•9 �I OTY=2 TOTAL=2 .r,� �� �fiN I •• * S REV. 8.07.00.1218.13 SEO= 11829 SCALE=0.3333 J011,10TMEINSTALLERS W v S\3 •�6 TCLL 20.Op6f REF 7 C- W TC DL 15.Op6f DATE 06-06-2009 =� • �\ w.�OF : z BC OL 1 O.OpSf DRWG BC LL 1 O.Opsf LEN. 220706 #: B0190 7t 1; 11 ...... V :ij i ry IJ I t?.: u Po film. _::AOL !08 .A .1 ziltol! z' —lito bqm �' Ttl 1.1 low r":; '19t,' PCanz. rt it i JDb:(BO190) MUM / MUM BUILUth15 -IJLU 1- / HJ1A Top chord 2x4 SP #2 ' Bat lard 2x4 SP 02 , Webs 2x4 SP #3 In Deu of dg`d ceiling use purist to brace SC ® 24. CC. Sub-fasda beam assumptions: 7-0-0 sub-fasda beam on the 3-2-3 cantilever aide. 7-0.0 sub -fascia beam on the 3-2-3 carNbver side. Defledon masts L/d60 live and L240 total load. AD wind load cases on this buss have a 1.33 duration motor. 186# 4'93/16' 12 3.64 p 9'10.13A6' IN THISOWS. Pft PA EU BY THBALPINEJUe UkZJIUN nI`MU r m rwum Inumm mrna wrvo. 140 mph wind. 24.63 R mean h9t, ASCO 7.05, CLOSED bldg. Located Anywhere In root, CAT It,, EXP C, wind TO DLS.O psf, wind BC DL 5I W=1 .0 psf. .00 GCpi(*)-0.18 Wind reactions based on MWFRS pressures. The fo#owing members rood concentrated bads at the heel: 7.60 spardsetback member on the 3-2-3 cam side requires 128 Ibs and the 7-0-0 spantsetback member on the 3.2.3 cam side requires 128lbs. Hipjack supports 7-0.0 setback jacks with 3-2-3 cantilever one lace; 3-2-3 cantilever opposhe face. Harming stresses not considered for plates. Handling otihis tots requires species care by truss manufacturer and Iretellallon cadramorto prevent plate damage. 51-9116' 11 5'1-9/16' 8=123# U=139# NAILED I I i� m J . 4um T616V] S 46-11/16' 3X4 2'10-11/16'- z ' 4'5.7/16' 4'S•5 ��' J R=8g8 tU�5�g�yy=1-1/2° 8=-131If Rw=189# NAILED R=12# =87=1-1/2' di C.•` • ..•.. 'es ��i� SEO= 11878 TAG T8 OTY=2 TOTAL=2 �� :• * • Wee REV. 8.07.00.1218.13 REV. SCALE=0.5034 PLTTA TYP.•WAVE ossos ran.re�aarcounry vrm*-xmamsnam '•WAR INO'•RBAD AND FOLLOW NOTES ON THIS DRAWI OI C V 6 {L. TCLL 20.0 Sf P REF "Ik1PpR{MT•FURNIOH THISOMWINOTOALL CONfRA010R9 WCWDINO THE INBMLLERB. mm�, .m•vm.mtmeemo w=smm•'°"°m'my rW.'m"° �.�. - 15.0p6f DATE 05-Ds2DOg mm•o.mmn.w•+B ecL(aarmo•emme•°mv�wn+•Jwrwvap avbaao•o+•w mmem w.mr,wro m.=omecv. 4,.,Q` TC DL ROOF m�c0.eremm•+•.muoewom,.cmomwr.a.wm.swm+a.emvm,mion • •z BC DL 10.0 Sf P DRWG TRUSSES vmm.s°nw°M.mms+wr'a memeem.imp.,bremm• �mwew If.." aemwmp•.w•mer.a,>a,s.umw>e•'4an'.•am..mm abm.dpLmnoYm•mw•mma.mo.ma,vssmeeam•.m. seem +suxl•m.mmpmwm•u °i.vvmaawnxwmm,soe�anmmm,um,mm.ro �� • ` AS1 r'1� BCLL I Q• 10.Opsf HALF MILE ' INDUSTRIES LLC. mv m•.s egme.mmwav,o°.o.m,ulsvmv.wveootq�a� `�.mn .w.m.cmeomm.+onay..�womoa..m. •ViW4•e•+dbmsMlornOgivon m.•ma.nu.ar►r'mr mrwwmmme.movmWde.msao.tr*wwevm+w. � • i� A � • 0o • � � \ • � •e. p L OP•'� •••...9 �r �� TOT.LD. DUR.FAC. 5$.0 Sf P 1.25 O/p LEN. 91001. WALL PANELS JOB #: B0190 TYPE, HIP JACK SO�N SPACING 24.0' ��� m Top lard 20 SP #2 Bar chord 2A SP e2 Webs ZA SP B3 In Qeu of dgid oegug use pudins,to brace BC ® 24' OC. Sub -fascia beam assumptions: 7-0-0 subdee cia beam on the 34-3 cam0ever aide. 7-0-0 subdasda beam on the 34-3 canolaver title. Deflection meets U360live and 1.1240 total load. All wind load cases on this tnss have a 1.33 duration factor. 1870 bidg, Located anywhere in red, Wind reactions based on MWFRS pressures wbM TC DLd.0 pat, The following members reed concentrated loads at the Creel; 7-0-0spardsetback member on the 3413 cad side requires 131 the and the 7-041 spanisetback member on the 34-3 cam side mquires 131 Ibs. i Hiplack supports 7-0-0 setback lacks +0a-4-3 cantilever one few; 3-4-3 cantilever opposite lace. Handling stresses not considered for plates. Hamf g of this inert; regdres spacial care bytn manufacturer and Installation comredorto prevent plate damage. I I 4'10-3/4' 5'0-1/16' 410-3/4' R=108# I NAILED (6 4oeua. ri 1,1 R=9g13/i U=920-13(7B 8# W=1- 4 ' R=-161# RW=212# NAILED RW=98# W=1-1/2' i O ' q 1 �. waRrF ••. TAG= TS �,��•� •NSE•+9 ••y SEQ= 11894 PLT. TYP.•WAVE oasaw ewr.raemmeowrnmoxnmr.emwa•yiwm OTY=2 TOTAL=r.� 2•• l :# • REV. 8.07.00.1218.13 SCALE=0.5034 "WARNINGI^RPd10 AND FOLLOW ALL NOTES ON THIS ORA G �� TC LL 20.0 sf REF. .IMPORTANT" FURNISH TXINOMWINOTOALL CONTRACTORS INt1W01NGTN2INSTALLEfiB. P � W �, W � inm.^pNa•n•m.FfMbeq r RM^betl m�.�•..+&rn°rGlr.mm Imo; '!� . W TC DL iS.OpSf DATE oe-gs-zoos ROOF PameWbie�•a•er•^ war p^Yb1YM1trNybsigrmeCSt ��� utid,m u.im m we br M pmeM baa.a minva+®+e.e wov ubs TRUSSES wM.amenrwemroar+q uvmbev�www•vm••,sma�.^� �_ 0 •�_� BC DL 1D.DpS DRWG 6NMbiYpwi]{veC6l One Blelval4egtr@Y A{paVAfbvY,iao • 1 avvb.nc.•m®bb^a^•bmn4.•o.m^bb •aemaw® • i HALF MILE amb rawxbnwaber.mu BC LL 10.Opsf INDUSTRIES LLC.9i ii Q• a �e.m..Fina^mv.mausnn..^drmmywpnFmmm 81001 �� ,p F �2,� TOT.LD. 55.Opsf O/A�LEN. WAfI, wrmne.•ovma.Pwr+ene.•cF�..mu.oaoaaamr ,p PARSES "d'+"•'�"'''�•w°11'�"b'" TM'�dyi0i0 7-/ '• L •� \� DUR.FAC. 1.25 JOB #: B0190 bw.Fcv.•r.n.w+ayanawvo.io.r.rusum.ma ••Ip , SPACING 24.0' TYPE HIP_JA( sov^.re �ea..wpv.w.:+,mro.br�ee.�eaz 1b:(BO190) M D M / MDM BUILDERS'BLD 1'V Top chord 2X4 SP #2 Sot chord 2x4 SP #2 Webs 2x4 SP #3 Roof ovelharg supports 2.00 pal soffit load. In lieu of rigid ceiling use pudins to brace SC ® 24' OC. Deflection meets U3601Ne and U240 total load All wind load cases on this truss have a 1.33 duration factor. 3X4iTi(B1) 6.716' _. I TAG = T13 PLT. TYP:WA' ROOF TRUSSES THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Negative reaction(s) of -294# MAX. (See below) from a nonwind load dace re ndres upli t conneption. 140 mph wind, 24.27It mean hgt, ASCE 7-05, CLOSED bldg, not located within 4.50 It front roof edge, CAT II, EXP C, YAnd TO DL=5.0 Pat, wind BC DI -9.0 pat. 1w 1100 GCpi(i/-)=0.18 i Member design based on both MW FRi S and CBC, wind reactions based on MW FRS. Bottom awed checked for 10.00 Pat ndn.wncurram live two. Handling stresses not considered for prides. Handling of this trusts regWms special care bytruss maradacturerr and Installation contractorto prevent plate damage. -- 17-7/16' — i 5'4-9/18' 3'9° 8# Rw=13# U=20# NAILED 12 4X4 5 p 1� i �3 p i 3X6 3'5 5/8' � 3'5-3/8' g� 1'4-15/160 —^tan i '- 55-A8=907# U=445# RL=208/-32# W=3.1/2'� R-295# RW=198# U=2 LED QTY= 2 TOTAL= 2 meelDRAW NaLUOIna THEINSTALLER& _ YIbfE A1�rrlar OI 1 16MnWN iA l Im.mr � Z_ {► SEIQ = 11697 r REV. 8.07.00.1218.13 SCALE=0.7229 MILL 20.Opsf REF 0 .TC DL 15.Opsf DATE 06-09.2009 DRWG ;A BC DL 10.0pSf BC LL 1 O.Opsf TOT.LD. 55.Opsf O/ALEN. 5D411 DUR.FAC. 1.25 JOB #: 80190 =JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Top chard 2x4 SP #2 Bot chord 2x4 SP #2 Webs 20 SP #3 Roof overhang supports 2.00 Pei soffit load. In lieu of rigid ceiling use pudins to brace BC ® 24' OC. Deflection meets U3601Ne and L1240 total load. Al wind load cases on this toss have a 1.33 duration factor. 2'5-3/8' 140 mph wind, 24.27 ft mean hgt, AS DL=5.0 psi, wind BC DL-5.0 pat. 1w- Member design based on both MWFi All plates are 2X4 except 0 noted. Bottom chord checked for 10.00 Pat i Handling stresses not considered for contractor to prevent plate damage. 2'9-7/16' 5'4.9/16' 3'O-1/4° R--33# U=122# NAILED 5, CLOSED bldg. not located Within 4.60 ff from roof edge, DAT,II, IXP C, wind TC C&C, wind reactions based on MWFRS. ' current live load. Handling of this toss requires special care by toss maradl wrer and installation 12 m 5 a. m3X4(B7). I N - C 2-3-5/8° f 6� 4E)- 2'33/8° —� 3'0- 5'5-5/8° - R=18 If U=100plf RL=66/-10pM W=3'2° it i 1 to O�glllll�! i TAG= T25 ♦ ((�. �HSS"�'�.• �Qr SEQ= 11802 PLT. TYP: WAVE oeasxcsmsacaacounwxm rrmr zox+owv+am QTY= 2 TOTAL= 2 :4% • * • REV. 8.07.00.1218.13 SCALE=0.7229 -wARNWQI-REAO ANDFO ALL NOT@BO TH MW NDI i "IMPORTANT" FURNISH THIS DIWWINO TOALLOOMMOrORl LUDINO THE INSrALLERB, �♦�-E TC LL ZO.Opsf REF! T'"®r1jJ1°•""m'"""•°" "h""b Yn°"he° ru"°i�`:d°«r QI'°Ij -_\ W ,TC DL 15.0psf DATE 06-09-20Ds Imw,e.m.�aecvla"'nm'4.,r"•°mew•wu«, mre `�W\ ROOF,.r°'em".°.°mme.°�m,roon«,o�m.m,ew.+`�.�e+e�°«,WWS`we ��( •W BC DL 10.OpSf DRWG TRUSSES w,w..e•nm.�mpppp«my vmw««"+«w°w.vex•,ne.ware. • ��. pyrm« bffiYtll"aL9 «LAl•aA.Ww0+0.rAat/ptl"bme,+eu `� «sauna a,o.,e«..iaw,v.+«uo.mw®.,mm.wva. 10.0 Sf HALF MILE +«�••Jwtrgf �w ^�•�01LL '� I . C7 8C LL p I+W G«�lf OfwNticNMbwN lw w/MNThtm YYelIs.04 i .� O `� INDUSTRIES I.I.C. A w.�iao.w.nm+w e.d*raenri+.«mtiowwwmo.w.v,m, �� A • \ •' Z`� TOT.LD. 55.Opsf O/A LEN. 60411 MALL Armen.+a«mrnwrsanm.+o+�-+�o.��dwawr • + !.` L Q� �,t, . PAN.o.•e,•en.nVrgae.m+o,.>r.. sn.•ravr,.ane.•s •q•w•N•T ♦ DUR.FAC. 1.25 JOB,#: B0190 •ems."..�am:a..,+`�„�,w ��II� F$$1O. P\\, SPACING 24.0' TYPE JACK j i I3F... ..JN r � J 1 . { i . .- . � M .M1. ♦.I m.t ,a .P ... �...: �. .�Ii1 f ')YU+ )tr r. u' owl ._4 ni. r' `.. -af. :5,6:Pi• 1 i Rob 7' Top chord 2x4 SP #2 . Bat ctrord 2x4 SP 02 Webs 2x4 SP 03 Roof overhang supports 200 pat soffit load. In Ileu of right celing use puntrts to brace BC 0 24' OC. Deflection meets U360live and L240 total load. Ali wind load cases on tits truss have a 1.33 duration factor. Negative reaction(s) of -353# MAX. 140 mph vMd, 2384 it mean hgt, P wind BC DL=5.0 psf. Iw=1.00 GCpi Member design based on both MIN Bottom chord checked for 10.00 ps I ) 27-1/8° MMvv--209# U=274# NAILED 5X6(R) 1 12 io I 5 o� I 2'35/8' z 3X6 4X4 3'3-11/16' R=715# U=362# RL= - W=1'0-1/16' below) from a rwn-wind load was requires uplift connection:, 7-05, CLOSED bldg, Located anywhere In roof, CAT II, E(P C. wtrM TC Of =5.0 psf, and CSC, wind reactions based on MWFRS. -concurrent five load. tes. Handing of this buss regdres special care by truss manufacturer and Installation PLT. T7P.rWAVE 42 oesox amkecxawanaun-amr:rml.mxro•vtasl OTY=2 TOTAL=2orS �O i`���yl� •NS E �!'!�9,'���y G� 6 * �� REV. 8.07.00.1218.13 SEa = 1 SCALE= ROOF TRUSSES a ^WARNINdl- AEAD ANDFOLLOW ALL NOTES ON THIS O WINO 'IMPORTANT' FURNISHTIIO OMWINO TO ALLCONTSACIORa INCWOWGTHE INSTALLERS, r,�Ave.mmm°®=nreban�lo.�Ne..�aered°no web.e ms.neem.sm,aeculaavyw�wma[ww ma�.•wnaa.mw a am•abr.�+•e•muwu wmim.cwwe*�mw• +rvw 'ro° . .rmlm.n•.mN..+'+.a,p]d+.lo ummed•.,idnm,•Iwm••m+ud.m YWluw brlghY6aIRtBC51u@anal �aelau� ennytlnb>,lo dwi.�,..�.n..w�'.,ra�i.x'd°�'me �mMbvaeuNimburetlaN.Ma jV - �Yi• • 1�r I T : • i 6 TCLL W 'TC DL i :Z� BC DL ` lO \ `�'I �� BC LL 20.OPSf 15.Opsf 10.Opsf 10.0psf REF DATE DRWG WALL. PANELS O/A LEN. 30212 JOB #: 80190 Top chord 2x4 SP #2 Bat chord 2x4 SP #2 Webs 20 SP 03 Roof overhang suppods2:00 Pat seftn bad. In lieu of rigid ceiling use puns to brace BC g 24' OC. Collection meets WW two and L240 total load. °'"' BEARING ANALOG MODIFIED! -'- TAG = T22 PLT. TYP: WAVE ROOF TRUSSES WALL PANELS THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT The maximum hodmmal reaction is373q" I 140 mph wind, 23.84It mean hilt. ASCE 7.05, CLOSED bldg, Located anywhere in roof, CAT II,,IXP C„wind TC DI -SO psf, wind BC DL=5.0 psf. Iw=1.00 GCpi(H-)-0.18 Member design based on both MW FRB and CSC, wbd reactions based on MWFRS. Bottom chord checked for 10.00 Pat norncon msnft live load. Hangrg stresses not considered for plates. Handling of M mass requires special care bynas mamdacturer and Installation comrsctorto prevent plate damage. i All wbd load cases on this truss have a 1.33 duration factor. i 2'5-1/8'fl3�&1M# Rh=374# RL=258/-207# NAILED 16 d �oe �11s 3'3-11/16' i 2'3-3/8' - 10-5/16°— ~ 3'3-11/16' R=118# U=93# Rh=-374# 0 NAILED Y� v g•� .I&M Tc LL zu.upsr .TC DL 15.0psf pF tea- BCDL 1O.Opsf Z BC LL 10.Opsf 11741 =1.0090 DATE - 06-09-2009 1 _EN. 30212 #: B0190 )b:(BO190) M D M / MDM BUILDERS'BLD 1: / Top chord 2X4 SP #2 Bot chord 2X4 SP #2 Webs 2X4 SP 03 Roof overhang supports 2.00 pat solit load. In Ilea of rigid ceiTing we pudins to brace BC ® 24' OC. Defection mees 1/3601ive and 11240 total load. All wed load cases on this toss have a 1.33 duration factor. 37-1/8' 3'35/8' — N 3'33/8' = T21 ROOF TRUSSES Negative reactions) of -267# MAX. 140 mph wind, 24.25 fl mean hgt, A DLd.O part, Wind BC DLd.O fast. Iw Member design based on both MWf Bottom chord checked for 10.00 Pat Handling stresses not considered fo contractor to prevent plate damage. 1'8-1/2' - 18-11/2/R=1## RRjW=8# U=28# NAILED � card e; N Is y 5'35I' R�53# U=412# RL205/31# J1�-1 R=-�6 k R =182# U=238# NAILED JOIN 2 TOTAL-- 2 SIGNER PROGRAM FROM TRUSS MFR'S IAVOUT a nonvAnd bad ease requires uplift eonngclion. :D bidg, not located Within 4.50 It from root edge, CAT II, EXP C. wind 7C CBC, wind reactlons based on MWFRS. aces. Hanging of this truss requires special care bytr ss meIufacturer and Installation SEO = SCALE TC LL ZU.UPST TC DL 15.Opsf BC DL 10.Opsf BC LL 10.0psf TOT.LD. 55.UPST O/A LEN. 50211 DUR.FAC. 1.25 JOB #: B0190 SPACING 24.0° 1 TVPF JACK Top chord 2x4 SP 02 Bol chord 2x4 SP #2 Webs 2x4 SP #3 Roof wedang supports 200 Pat soffit load. In Oeu of dgid ceiling use purfins to brace BC 0 24' OC. Collection meets L/3601Ne and L240 total load All wind load cases on this truss have a 1.33 duralicn factor. TAG = T6 ROOF 7RUSSES 140 mph WrKL 24.25 ft mean hgt, ASCE 7-05, CLOSED hidg, not Iocatedwit in 4.504 from root edge, CAT II, 'EXP C. wind TO • DIs5.O psl, WuM BC DL-3.0 psf. Iv 1.00 GCpi(N-)-0.18 " " Member design based pn both MWFRS'and C&C, wind reactions based on MWFRS.. AS plates are 2X4 except as noted Bottan chord checked for 10.00 psf noricorormeM live load Handling dresses not earsldered for plates. Handing M this truss requires special rare frytnss m i ulachner and Irslefietian contractor to prevent plate damage. 'I I 2'8-1/2'� 2'53/8' 2'10-114' R--22# U=117# Z ° 2'33/8° INSIAU9148. NAILED ! ! i a m m m a a N` y I i IOOPIf RL=68/-10pIf W=3' 1 I 'O 2 REV. 8.07.00.1218.13 TO LL 20.Opsf TC DL 15.Opsf BC DL 10.OPsf BC LL 10.0Psf TOT.LD. 55.Opsf DUR.FAC. 1.25 O/A LEN. 50203 JOB #: B0190 24.0' i � a. ,. �1 i - %-� I z - _ _. - .. - - � _ Y .. . !- .gip .. . ,. , ..., 4 j{py( ddAi -0'fiZ ONIOHdS /1)�'tl3N0I630 31IOlI 9 3H1 d0 AlIlI9I5NOd538 3N1 eI ONTO II N ANN boi mmod cu Day -,an 0 3en ONH A1IlI9tl1IM 311 NAOHS N9IS30 1N3NDA o3 SS(MI ML HOd A13MB AIIIISISMdS3tl 06T08 # 80f SZ' T y'a 7MOISS3i0Sd 30 37Ntlld3�tl 831tl7I0NI ONIAtleO SINI NO T33 tl e 339 moz-T Ial eo stgrivd A •� ➢I! X3 Od 39 TM M AS mAD110A S3 bld d0 N01103&NI ANI Z-WOST SSNIAHM H3d NOIlISOd 77VA L ' Nil a'/0 js 0 • SS 01' lca ; 1. NI m1N701 3SIMH3 UO SS31M 65f17LL 30 3311 117tl3 01 631tl1d A•Iddl -13315 'nitl0 �� N111 OS/Ob 0 EMU N1SU 01/SSM N U5ST/9T/0Z d0 30HU 3HH 531 tl0103NN03 030 All 311 $3RLLSTIONI • • . @GNUMd1dtl AS tla3d8 N(IIS30 11RPIIW SDtj AD SNOISIAOHd 31980I1ddtl HIM SNW9lOa MI530 �Sdp pT 11 p AM MIDUMS I MITH1SNI SNIMIHS SNIIOMH SNIMILSHA HD :Idl ILIA 33YWW:ROJ 311M JWH Ssn,4 3N1 OIINS OL 3NIlItld ANU :NSIS30 SIHL WHA NOIIHIA30 ANH HOd 3191SNO M M ION OMaO sd 10 0 9 �•t�1 ONI Sae. ALI NO13HN1NOa NII1Hlltl1SNI 01 NOIS30 SIHL AD AdOO MINUTIA /,i1fflNH��og� fty�, IV'r ENIlI30 OISIH 0 YiiH /41H3d0Hd H mm THHs omom N011QS-lYM Sl3FMd .s+SSM Q/ A 03MU 1H AItl3dMd 3AM IIWS MWO dol 0311T11IN11 3SII§H3N10 SS3Vil SNOI43NLH 3S3 d00S SOOZ-TT-90 31a0 jsdp'C�`T 10 31 • i5 q HM M HOIad S331136M AMAWS 804 (STIES •IA, N09ION r 3SIM31M DOES �laltllltl 3O *••• N • 07 S&IHL MOIO U3LA MM FbTWZ HA WISMIA3-U ZTE 3LIO5 the 331 HIMN STZ 31(LLI1911 j3a Jsdp • pZ 11 31 �I� �•.6. �.••:• 5�115NI1"AJNI Idd I6I Il�N1 11d7IffiNlHNI 3H1p 3MSLX3�I II(�iO3N 0m1Hlui :tl SN: i OOSZ'0- 31H0}3'8T2T'00'L0'8 "A3a �I (' 8 -1H101 8 -A10 wm/ommz-llVld mot-xdl/wacmmellxm mxe3u 3AHM-•dAI 'lld 019ZT - DAS ��/I �p�p���� 1 ` 1.8.6 - Di 1HOI8 �, bo `t Z-8.6 SEBIr-1331 fi-b.Z - 3MUH 1331 j. 31IHN #LIT-n #06T=8 •.8=M #fiLE /L6fi=la #09T=n #fi6S=2i fiXZ Z� I X f W o m m k" W cn co XE m . �VIVO� XE 031IUN #ZTZ=n #9TZ-8 T S ZT-L.9 - •uo}ooJ uol}ounp Sg•T n awoy ssnu{ elyl uo SBeno pool PuIM IIH i -pool lo}o} ObZ/l Pun awllj 09E/'l 6+8ew u014.eeIJBO •eouougelo epin- bZ x 4614-.Zfi 44IM SBBJa ul pool ew11 pu040 wo{}oq louol}Ippo Jed 0Z joJ �loeyo peseod asn.xl -pool poop o} enp .90.0 Pun pool ewll o{ enp .Zfi •O al u0l{oald P to{uoz woy pe}nlnolo •SHAMH uo peBoq suol}aoeu pulp '083 Pun SHAMA 44eq uo pesoq u6leep aegwep . ' el loJOI -Jed 0'9-l0 39 PuIM 'Jed PuIM :guoeIwI IU3 'a6P do.wJJ d ti OS'fi my}IM pe{000l {ou :6p19 03SOIOSO-L 33SH }Ll }d 6fi'LT 'Pu1M ydw 0fiT 1n0AHl S.6d<7 SSN61 H09d Htl600!ld 83NDIS30 90f 3NIdlH 3H1IA8 03HHd3Ud 'SAO SI141 •e6owop a}old }uewB�d o} .o{000}uoo uol}ollo}eul pun ueun}oodnuow eanu{ Rq euoo loloeds ee.11nbeu eenu{ sl4} Jo 6ullpuaH •ee}old JOJ peuePleuao {ou aBSBSJ}e 6ullPuoH -Pool enll }uauunouoo_uau Jed 00.OT JOJ POA0840 pQoyo w0{}06 •30 .bz 0 39 eoowq o{ eullund Ban 6ulllso pl6l.+ Jo nail uI •e6ulJawoo Ilum elglxolJ pun el}{Ijq joJ o1Je4Iwo ObZ/-1 e{eew uol{oeljoa •eunseeud pulp ol. pesodxe 1001408A PUS 4Jel :6# dS fixZ ujn{oa lewal }•l: :E# dS fixZ ZM: Z# dS fixZ a9aA SS dS fixZ puoyo yoS ' eaue0 Z# dS fixZ PJoyo d01 SME Was W 'AY51 PC .... ..... to, it any r"Ll IWQl p,.l OL 11 ic LO w'.03., 1 W_!V UrL,_ ll OWLS 101, Il, ­.i"a M!,Ij n 10 P� 171� q"q 10 t.l 001-, t_i. Id., ob:1601901 M D M / MOM BUILDERS "BLD 1" / CJ5 Top chord 2x4 SP #2 Bot chard 2x4 SP SS ' Webs 2x4 SP #2 :W2 2x4 SP #3: :Lt Level Return 2x4 SP #3: Left end vertical exposed to wind pressure. Deflection meets L/240 criteria For brittle and flexible wall coverings. In lieu of rigid calling use purllne to brace BC O 24" OC. Bottom chord checked for 10.00 peF non-aonourrent live load. •o WRRNINGI Overhang deflections excessive fi Truss has vertical deflection on overhang of 0.23" due to live load and 0.03- due to dead load at X --2-1-11. Creep Increase Factor For dead load is 1.00. RII wind Iced oases an thls'truss have a 1.33 duration Factor. 12` 4 7"12 — U=lBB1# NAILED II ti V®VVV 1 R-495# U-195# RL-454/-359# W-8 R-126# Rw-167# U-203# RAKE - 2'4"4 -JIG16 7'8"B fYP.-WAVE ROOF TRUSSES. HALFMILE INDUSTRIES LLC. L Z WALL PANELS THIS OWG. PREPARED BYTHE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT 140 mph wind, 17.08 Ft aeon hpt RSCE 7-05 'CLOSED bldgnoT loomtdd within 4.50 Ft From roof edge, CRT II, EXP C, wind TC 6L-5.0 peF, wind BC OL-5.0 peF. Iw-1.00 GCpI(+/-)-0.18.� ' Member design based on both MWFRS and CBC, wind remotions based on MWFRS. Calculated horizontal deflection is 0.52" due to live load and O.OS" due to dead load. i Trues passed check For 20 psF additional bottom chord live load In areas with 42"-high x 24"-wide cledrance. OeFlection meets L/360 live and L/Z40 total load. I Handling stresses not ocneldered for plates. Handling of this truss requires special care by truss manufacturer and Installation contractor to prevent plate damage. "Mr 1 nnoae OTY- 8 TOTAL- 8 RIGHT 8.07.00.1218.. LL 20.OpsF F OL 15.0psF E OL 10.0psF E LL 10.OpsF -LD. 55.ODsF E 06-11-2005 -EN. 5 #: B0180 ob:(BO190) M 0 M / MOM BUILDERS "BLD 1" / CJ3 Top chord 2x4 SP-#2 ' SoT chord 2x4 SP #2 Webs 2x4 SP #2 Dense :W2 2x4 SP #3: :Lt Level Return 2x4 SP #2: ' LeFt end vertloal exposed to wind pressure. Deflection meets L/240 criteria for brittle and flexible wall coverings. Bottom chord checked for 10.00 peF non-oonourrent live load. DeFlectlon meets L/360 live and L/240 total load. RII wind load oases on'thls trues have a 1.33 duration Factor. 12 "- 27"12 5 �l R=73# -611 �2 3 3XG 2X4 R-396# U-274# RL-389/-344# W-8" R=44# RW=258# U=30 ILED 140 mph wind, 16.66 Ft roof, CRT II EXP C, wl GCpIC+/-)-O.IB Member design booed on In lieu of rigid oelllr Trues paesed check For 42"-hl gh x 24"-wide ale Handling stresses not c special core bg truss m damage. LEFT RAKE - 2'4"4 LEFT JIG - 5'10"7 TAG - T18 PLT. TYP.-WAVE ROOF TRUSSES an hgt, RSCE 7-05CLOSED 61dg , Loc TC OL-5.0 psF, wind BC OL-S.O ,par. th MWFRS and CBC, wind reactions be use purllne to brace BC 0 24- CC. peF additional bottom chord live I MFRRS LAYOUT ' 4 aridwhere In I " an MWFRS. In areas with For plates. Handling of this trues requires r and Installation contractor to prevent plate RIGHT JIG — 5'11"12 SEO — 12595 REV. 8.07.00.1218.EERLE—0.3750 TC LL 20.OpsF REF C DL 15.OpsF ORTE -06-11-2009 CG OL 10.OPSF DRWG • _ LL 10.0psF • T.LO. 55.0 sF O/R LEN. 3 r• 1C(1R'.FAC. 1.25 JOB #: B0190 ';Z4i_ PRCING 24.0" TYPE JACK Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP SS =W2 2x4 SP #3= =Lt Level Return 2x4 SP 42: Left and vertical exposed to wind pressure. Oarlectlon meets L/240 criteria For brittle and Flexible wall coverings. Deflection meats L/360 live and L/240 total load. RII wind load cases on this trues have a 1.33 duration Factor. 12 5 R--72# 5X6 (R) 4X4 CRl 0 i Rw=86# U=64# NAILED On i*) 140 mph wind. 15.24 Ft meen hot, RSCE 7-D5O CLOSED bldgg, Located on where In roof CRT II EXP C, wlnd ITC L-5.0 par, wind BC DL-5.0 per. Iw-1.0� 13CP1f4-9-0.18 Member design booed on bo I MWFRS and CLC, wind reactions based on MWFRS. In Ileu or rigid calling use purllns to brace BC 0 24" OC. I Bottom chord checked For i0.00 par non-ccnourrent live load. Handling stresses not cone [dared for plates. Handling of this trues requires special dare bq truss manufacturer and Installation contractor to prevent plate damage. i ~2 3X6~� 2X4 w R=417# Rw=600# U-644# RL-326/-328# W=8" R--72# Ru=668# U=704# NAILED RON LEFT RAKE - 2'4"4 LEFT JIGTAG 4'4"4 ROOF TRUSSES HALF MILE WALL PANELS RIGHT SEOJIG = 12586 P. 8.07.00.1218.EERLE-0.3750 LL 20.OpsF REF OL 15.OpsF DATE 06-11-2009 OL 10.0pSF ORWG LL 10.OpsF .LO. 55.0 sF O/R 'LEN. I %FAC. 1.25 JOB #= B0190 ICING 24.0" TYPE JACK s' XmBRACE,D - , Provide two braces each girder within 4 ft. of end ofetevated section [see A1G, A6 truss Eng.3 ;el Date:06/10/09 Blagonat Brace approx. 12 nail each end with 3-16d as Sh L In addition to bracing shown Bruce trusses according to BCSI-91 Attached Al G Girder Rat Run - L11end CLB [rat runs] to HJ9 at each end w/ 2-1 d into top of each bot. chod GENERAL NOTES: All new bracing: Use 2 x ,4 Southern Yellow Pine HA � WIL 9500 WEST ATLAtm AV. DEIRAY BEACH FL ,pe LOCA710N: FT. Pn RCE' i Florb° ' I 1#48FL. PE854395