HomeMy WebLinkAboutLETTERS FROM RICHARD WARD ARCHITECTS - PLANNERSRichard Wensing Rrchitects & Planners, PR member american institute of architects SCANNED BY St. Lucie County 4-14-09 Code Compliance Division 2300 Virginia Avenue Ft. Pierce, Fl 34982 Attention: Plan Reviewers Answers to Plan Review Comments 3-30-09 Reviews and Comments Permit Number 0807-0168 Dear Sir: Attached are the answers to the Plan Review Comments: Plans Examiner Review: Ed DeGennaro Comment #02/2012009 3, Page 2: Provide on drawings the following information per FBC Section 106.3.5, "commercial buildings", occupancy group, type of construction, occupant load, SF, ETC. Classification FBC Section 302. Building area & height, actual & allowed per table 503. Occupant load FBC table 1004.1.2 Answer: See revised sheet SP- I and LS- I for corrections. Crexent Business Center* 2101 VistoParkwoy a Suite 108 @ West Palm Beoch, FL33411 - (561) 684-1988/ Fox (561) 228-6132 AFIK0021 81 Comment #02/20/2009 4, Page 2: Provide a Life Safety Plan complying with FBC 106.3.5(6) and tablel 0 15. 1. Answer: See new sheet LS-1. If you have any questions with regards to these plans for this building please call our office. Thanks, Richard Wensing RW/em I Richard Wensing Rrchitects & Planners, PR member american institute of architects 4-1-09 Code Compliance Division 2300 Virginia Avenue Ft. Pierce, F1 34982 Attention: Plan Reviewers Answers to 3rd Plan Review Comments 3-30-09 Reviews and Comments Permit Number 0807-0168 Dear Sir: Attached are the answers to the Plan Review Comments: Plans Examiner Review: Ed DeGennaro Comment #03/24/2009 21, Page 2: Englert series 1300 aluminum metal panel roofing submitted requires a fire barrier board per system A-1, NOA #05-033 1.01. Answer: As per attached Florida Approvals the Fire Barrier Board is not necessary. This test only applied to Dade County and is not applicable to the rest of the State. See attached Evaluation Report, Certificate of Independence for Evaluation and Installation Method. See attachment 'C'. Crexent Business Center - 2101 VistoPorUway-Sulte 108 - West Palm Beach, FL 33411 - (561) 684-1988/Fox(561) 228-6132 AXC002181 Comment #03/25/2009 22, Page 2: Johns Manville NOA #06-0626.04 submitted must be highlighted fQrskeLproducts being used, and including the deck type application, meeting the design pressure on sheet S-2, and general limitation page and including engineers calculations (general limitation #7) if required. Answer: See attachment 'A' (NOA #06-0626.04) and sheet A-6. Comment #03/25/2009 23, Page 2: Exterior stucco must conform to FBC section 1404.2. 1. Answer: See detail I on revised sheets A-9 and A- 10. Plans Examiner Review: Lydia Galbraith Comment #03/25/2009 22, Page 3: The generator is not meeting code. Minimum distance to a building is 10'. If there are no windows and doors on the side of the building where the generator is located and the exhaust is not going into any vents, the distance can be reduced to 5'. Answer: See Attachment '13' and revised sheet A- I for exact location and dimensions. Comment H03/25/2009 23, Page 3: The generator requires a separate permit. Answer: Issue will be handled by Owner and General Contractor. Comment #03/25/2009 24, Page 3: The name on the tank and piping plan still needs to be revised. Answer: Issue will be handled by company in charge. If you have any questions with regards to these plans for this building please call our office. Thanks, Richard Wensing RW/em Richard Wensing Rrchitects & Planners, PA member american institute of architects 2-26-09 Code Compliance Division 2300 Virginia Avenue Ft. Pierce, Fl 34982 Attention: Plan Reviewers Answers to 2 nd Plan Review Comments 2-20-09 Reviews and Comments Permit Number 0807-0169 Dear Sir: Attached are the answers to the Plan Review Comments: Plans Examiner Review: Ed DeGennaro Comment #02/20/2009 1, Page 2: Answer: Provide three signed and sealed copies of St. Lucie County "Design Certification for Wind Load Compliance" See attachment 'I'. Comment #02/20/2009 2, Page 2: Provide three signed and sealed copies of St. Lucie County "Product review Affidavit" completely filled out for all cladding components. Crexent Business Center - 2101 Vista Parkway - Suite 108 - West Palm Beach, FL 33411 - (561) 684-1988 / Fox (561) 228-6132 AFIK002181 Answer: See attachment '2'. Comment #02/20/2009 3, Page 2: Provide on drawings the following information per FBC Section 106.3.5, "commercial buildings", occupancy group, type of construction, occupant load, SF, ETC. Answer: See Revised sheet SP- I for corrections. Comment #02/20/2009 4, Page 2: Provide a Life Safety Plan complying with FBC 106.3.5(6) and table 10 15. 1. Answer: See new sheet LS-1. Comment #02/20/2009 5, Page 2: Provide on plans design pressure at openings FBC 1609.62.2 and table 1609.6.2.1 (1). Answer: See revised sheets A-3 and A-4 for revisions. Comment #02/20/2009 6, Page 2: Provide design pressure, gauge, attachment details and assembly for Englert series 2000 standing seam roofing. Answer: See detail number 4 and 5 on revised sheet A-9. Also see detail 4 on revised Sheet A- 10. Comment #02/20/2009 7, Page 2: Provide three sets of manufacturers truss placement plans, reviewed and approved for construction by engineer of records. Answer: It will be provided by Contractor. Comment #02/20/2009 8, Page 2: Provide roofing system details for flat roof and adjacent walls. Answer: See detail I and 3 on Sheet A-9 and detail I and 2 on Sheet A- 10 for roof system details for flat roof and adjacent walls. Comment #02/20/2009 9, Page 2: Provide eve attachment details complying with FBC section 1609 and 1404.2.1 Answer: See revised Roof Framing Plan and Schedule on Sheet S-2. Calculations have been made for each individual situation for uplift at the soffits and schedules changes accordingly. Also, see sections on A-9 & A- 10 for vapor barrier shown on C-Store as required under 1404.2. 1. Comment #02/20/2009 10, Page 2: Provide Thermal Expansion protection. Answer: See revised Sheet P-2. Comment #02/20/2009 11, Page 2: Provide water hammer arrestors for solenoid valves and urinal. Answer: See revised Sheet P-2. Comment NO2/20/2009 12, Page 2: Provide shut-off valves for each hose Bibb. Answer: See water riser on revised Sheet P-2. Comment #02/20/2009 13, Page 2: Provide P-3 list electric water heater manufacturers that we are not familiar with, if used they must meet code. Answer: See revised Sheet P-2 and Sheet P-3. Comment #02/20/2009 14, Page 3: Plan page E-1: show disconnects means at water heater. Answer: See revised Sheet E-1. Comment #02/20/2009 15, Page 3: Plan Page E-1: show location of panel "G". Answer: See Sheet E- I and E-2 for location. Comment #02/20/2009 16, Page 3: Plan Page E-1: show location of conduits to canopy and fuel pump if passing under store. Answer: See revised Sheet E-1. Comment #02/20/2009 17, Page 3: Plan Page E-1: show location, size and type of conduits from panel "B" to future lift station. Answer: See revised Sheet E-1. Comment #02/20/2009 18, Page 3: Plan Page E-2; show service entrance and 3 V2" feeder conduits to transfer switch and gutter on riser diagram. Answer: See revised Sheet E-2. Plans Examiner Review: Lydia Galbraith Comment #07/18/2008 3, Page 3: We need a sub summery and sub agreements for electrical, plumbing, mechanical and roof. The roof sub requires a roof contractor GC is not allowed to do metal roof. 8/22/08 they will bring it in before pick up, they don't know yet who the subs are going to be. 2/11/09 will submit subs when ready for pick up. Answer: Will be provided by General Contractor. Comment #01/23/2009 16, Page 3: E-mail from Yvette, ERD, site plan extension approved, still working on their issues with the scrubs jays, need to be resolved before they can clear the site. Answer: Issues will be handled by Owner and General Contractor. Comment #02/11/2009 18, Page 3: 2/11/09 the submitted page in not having the same as the site plan and the rest of the building set. Answer: Architectural site plan has been changes to agree with Civil engineer's plan which was the Site Plan Review Plan. Generator has been moved. See architectural plan. When site plan was approved the Generator was not shown. Comment 902/11/2009 19, Page 3: I . . a The pages SP-1, A- I A and A-7 still need to be revised showing the correct location of parking space 1, the location of the air vacuum and the location of the tank slab. All the pages in the building set need to show the same information. Please submit from each page 3 signed and sealed corrected pages by the engineer and/ or architect of records. Answer: Architectural plans SP- I and A-7 have been changed. The underground petroleum tanks as shown on A- I A are required to be positioned as shown in order for the tanker truck to drop their load. This is only done'off of the rear, passenger, side of the truck. Comment #02/16/2009 20, Page 4: License from the General Contractor is still on hold. We updated the state license, but the fees for the county cert. still need to be paid. License is still on hold. Answer: Will be done by the Contractor. Comment #02/17/2009 21, Page 4: 2/16/09 new comments to contractor by fax and owner by mail. 2/17/09 forwarded to plan review. Need to return to zoning for ERD and storm water check. Plan review fee needs to be adjusted. Answer: N/A. If you have any questions with regards to these plans for this building please call our office. Thanks, Richard Wensing RW/em