Loading...
HomeMy WebLinkAboutPERMIT WORKSHEETPERMIT WORKSHEET PERMIT NUMBER QQq g- InF, taller L�sA- License # Addressofhome being Installed I Manufacturer , ._Af0(_ LengIhxwidh NOTE.- if home is a single wide fill out one half of the blocking plan If home is a triple or quad wide sketch in remainder of home I unders land Laterst(Arm System s cannot be used on any horn a (now r used) where the sldewall ties exceed 5 It 4 in. Installer's ir :�f Typical pier spacing 2' 1� ' i�� I 101Wd [j_ Show locations of Longitudinal and Lateral Systems D" (use dark lines to show these locations) '.7 —in r r r 7 - T - r - r -i- J- 1 - I - L 41. IL 11 + J-1-L _L_r� I . I . .- L j i L L - L -I- IL 11 4 - - r IL + r .2-, ' " -L -, L .1 - ?tll - 11 - 11 New Home 1:1 pa el of 2 Used Home Home Installed to the Manufacturer's Installation Manuel 0 Home is installed in accordance with Rule 15-C Single wide Wind Zone It ;!g� Wind Zone III Double wide installation Decal # 1 (10 5 1 L5 Triple/Quad E] Serial # 15 (0 D-D- 130 PIER SPACING TABLE FOR USED HOMES bearing capacity __—Tgpa� s'� (Sq , in) 16'. x 1G.' (256) --- 18 1/2" x 18 1/2" (342) ____7� 2V'x 20" (400) 22" x 22" (484)- 24" X 24" (576)- 26" x 26" (676) T_ 0 71� U �Ps 8, EmISE 8�_ __T_ _T� __T�_ __T_ P I _�ERP A D 8 IZ �ES I-beam pier pad size CA0 Yl� Perimeter pier pad size IV I 0-k- d 0 0 fe-, Other pier pad sizes (required by the mfg.) Draw the a pproxim ate locations of in arrla� wall openings 4 foot or greater. Use this symbol to show the piers, List all marriage wall openings greater than 4 foo and [heir pier pad sizes below. Opening Pier pad size I POPU gK],� F ANCHORS 4 ft q within 2'af en� of home _,I,' spaced at 5'4," oc J TIE)OWNC Number Longitudinal 9tabil' i g Device (LSD) Sidewall Manufacturer. Vo Longitudinal Longitudinal Stabilizing Device wl Lateral Arms Marriage wall, Manufacturer:�. Shearwail PERMIT NUMBER The pocket penetrometer tests are roundad"down to Psf or check hereto declare 100o Ile. s oil V' withouiT—testing x — x — PO IETP NE 'ROMETER TESTING METHOD T Te:1 thle e p:ril. -ne ter of the home at 6 locations, 2. -Take the reading at the depth of the factor, 3. Using 500 lb. Increments, take the lowest reading and round down to that Increment. X_ X_ X_ PERMIT WORKSHEET The results of the torque probe test is Inch pounds or check here if you are declarin j83� _q 5'anChDrS without testing Showing 275 inch�pouj' _. A test ids or less will require 5 fact anchors, Note: A 8 late approved lateral arm system is being used and 4 ft. anchors are allowed at the sIdewall locations. I understand 5 ft anchors are required at all centerline tie points where the torque test reading is 275 or less and where the mobile home manufacturer may requires anchors with 4POQjIb holding capacity. _. Lfl Installer's initials ALLTESTS MUST BE PERFORMED BYA LICENSED INSTALLER Installer Name J=�� Date Tested Connect electrical conductors between MUlti-wIde units but not to the main power Source. This includes the bonding wire between mult-W cle u nits. Pg, Connectall sewerdrains loan e)dsting sewer tap or septic ank. Pg,_ Car, nectall Potable water supply piping loan e)dsting water meter, water tap. or other Page 2 of 2 Debris and organic material removed P7P Water drainage: Natural _ Swale W—Pa—dV/ Oth6r Floor: Type Fastener: Length: Spacing: Walls: Type Fes Length: Roof., Type Fes Spacing: 1� For used nome-4 Length: Spa in a a mill. 30 gauge,_� Twide. gaivanized'171etal strip will be centered over the peak of the roof and fastened with galv. roofing nails at 2" on center on both sides ofthe centerlIne. I understand a properly installed gasket is a requirement of all new and used homes and that condensation, mold, rneldew end bijcl(lpd marr'�'ge Walls are a result of a poorly Installed or no gasket being installed, I unde'rstand a strip of tape will not serve as a gasket. Installer's initials Type gasket ....... Installed: I Pg. Between Floors Yes Between Walls Yes Bottom of ridgebeam_Y�s —I— Weatherproofing The boftomboard will be repaired and/ol, taped. Yes Sidling on units is installed to manu P6. facturer's specifications, Yes ;L,�' Fireplace chimney installed so as "Of to allow intrusion of rain we tarYes iz UlAscellaneous Skirting to be Installed, Yes L---N a Dryer vent ins tailed outs kle of s kirtin ' Yes N/A Range downflow vent installed Outside of skirt ng. Yes �NIA Drain lines supported at 4 foot intervals. ye Electrical crossovers protected. Yes Other: nstaller verifies all Information given with this Perim iS accurate and true based on the manufacturer's Installation instructions and or Rule Installer signature