HomeMy WebLinkAboutRADCO LETTERYOUR VISION . O;OR. MISSION' December 20, 2012 Mr. Floyd Johnson Style Crest Inc. 600 Hagerty Drive Fremont, OH 43420 Dear Mr. Johnson: SCANNED BY St. Lucie County RESOURCE 11t "2a APPLICATIONS, COP DESIGNS& CONTROLS, INC. 3220 F-59TH STREET LONG BEACH, CA 90805 Tel (562) 272-7231 Fax (562) 529.7513 vmvv.RADCOincmm email:info@RADCOinc.com RE: Review AT[ test report on fiberglass coated plywood steps for compliance with the most recent code versions We have received the test report you submitted from.Architectural Testing (AM), York, PA. The details areas follows: Report number. 01-3791104, dated 1117103 Title: Step Performance Test Report Products covered: 4-Tread, Dura-Grip II, Step Unit [A five riser, four tread step;fabricated with pressure treated lumber and fiberglass]. At your request, we have evaluated the test report against the building codes outlined below. CODE 2006International-Building Code QBC) Stairway Dimension Requirement Tested Value (2) Compliance Width.(1) 36" minimum 38" Pass (1) Riser Height 7" maximum, 4" minimum 7" Pass. Tread Depth 11" minimum 11-1/2" Pass Tread Leading Edge Radius 1/2" maximum Less than 1/2" Pass CODE _ 20001riternat)onal Residential Code (IRC) Stairway Dimension Requirement Tested Value (2) Compliance Width 36" minimum 38" Pass RiserHelght 7-314" maximum 7" Pass Tread Depth 10" minimum 11-1/2" Pass Tread Leading Edge Radius 9/16" maximum Less than 112" Pass vum saRm INSTRUfE Z ri utncrn Mr. Floyd Johnson Style Crest Inc. CODE: 260T FlondalBuildmg COde;(FB-C .' Stairway Dimension Requirement Tested Value (2) Compliance Width 36" minimum 38" Pass (1) Riser Height 7" maximum; 4" minimum 7" Pass Tread Depth 11" minimum 11-1/2" Pass Tread Leading Edge Radius 1/2"maximum Less than 1/2" Pass CODE,.. •' ,,.., 20091ritemational.Budding,Code,(IBC);; Stairway Dimension Requirement Tested Value (2) Compliance Width 36" minimum 38" Pass (1) Riser Height 7" maximum, 4" minimum 7" Pass Tread Depth 11" minimum 11-1/2" Pass Tread Leading Edge Radius 9116" maximum Less than 112" Pass CODE - . 2009.international, Residential Code (IKC) - Stairway Dimension Requirement Tested Value (2) Compliance Width 36" minimum 38" Pass Riser Height 7-W' maximum T' Pass Tread Depth 10" minimum 11-1/2" Pass Tread Leading Edge Radius 9116" maximum Less than 112" Pass CODE. 2010 Flonda.Buildmg Code.-(FBE)-', - Stairway Dimension Requirement Tested Value (2) Compliance Width 36" minimum 38" Pass (1) Riser Height 7" maximum, 4" minimum 7" Pass Tread Depth 11" minimum 11-1/2" Pass Tread Leading Edge Radius 9116" maximum Less than 1/2" Pass CODE 20121nternational Buildmg`Cod_e (IBC) Stairway Dimension Requirement Tested Value (2) Compliance Width 36" minimum 38" Pass (1) Riser Height 7" maximum,.4" minimum 7" Pass Tread Depth 11" minimum 11-112" Pass Tread Leading. Edge Radius 9/16" maximum Less than 1/2" Pass VERTICAL VINYL SKIRTING ( components S installation J TOP SgCst AM-rAti{SM, W1rli 1rocH Scaaws 16"Aonar FLOOR SMAPS 6A70 -r" BArx ►41o" SCREWS AND PANEL C. -S .3.91A Wss me FOOT SEC UREb qP vEMPIL^-r1w TQ =bP. 64CK APID 13D7`7'OM l:(�IL ya 1y14N SL$Ews lfot' Or- I rALLPANELS AIMAC[6418ie §Y ftvftuUY6 iDP r-gra4T AN6 n.d j ) UPON PANEL , ATTACHEO -iv GBOuwm WIT% T Ic' GA414MItEO_MML 19"06 (IF 561L IS 5A#4D'g-l'86N fh-puc)' SUPPORT F's .R• ems