HomeMy WebLinkAboutREVIEW COMMENTSma ]c."�iz�irt ISO Planning & Development Services Building &.Code Regulation Division 2300 Virginia Avenue FortPierce,FL 34982 Phone:(772)462-2172-Fax:(772)462.6443 October 07. 2013 SEMINOLE MOBIL PARK LLC 370 EAST MAPLE RD 3RD FLOOR BIRMINGHAM, MI 48009 REVIEW COMMENTS FOR OWNER SCANNED BY St. Lucie Coun Page 1 of 2 RE: Building Permit Number 1306-0047 As of today's date your Contractor is being notified along with yourself that the referenced buiding permit has some issues listed in the comments below. We have asked that these issues be dealt with as quickly as possible so that we are able to continue to process this permit in a timely manner. This information is being shared with you so you are aware of the status of your permit. PROPERTYINFORMATION 3318 ORANGE AVE 49 FORT PIERCE, FL 34947 APPLICATION INFORMATION Permit Number: 1306-0047 Permit Type: Mobile Home REVIEWS AND COMMENTS Review Tvpe Status Front Counter Review Complete Comment: Documents Missing Pending 6/41201310:39:25 AM Comment: 6/4/201310:39:25 AM Comment: 61412013 10:39:25 AM Comment: Reviewed By Audrey Humphrey Audrey Humphrey FILLED LANDS AFFIDAVIT 24994 LISNS MOBILE HOME MOVERS & INSTALLERS INC LISA C FASNACHT 1500 MARINER BAY BLVD FORT PIERCE, FL 34949 Stories: 1 Date Started Date Completed Date Released 6/4/2013 6/4/2013 6/4/2013 VEGETATION PERMIT SUBMITTED TO ERD SUBMITTAL DOCUMENT FORM NOT SIGNED RETURNED TO RUNNER 6/4/2013 6/5120133:30:31 PM Comment: SUB -AGREEMENTS WITH ORIGINAL SIGNATURE -FOR ELEGTRICAL—PLUMBING AND -MECHANICAL — (IF APPLICABLE) AND SUB SUMMARY SHEET To be reviewed by Zoning Complete Comment: 6/5/2013 614/2013 Monday, October 07, 2013 3:29 PM �r l�• �ur�i G Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772(462.6443 REVIEW COMMENTS FOR OWNER Page 2 of 2 Environmental Review Complete Ben Balser 6/10/2013 6/4/2013 Comment: Zoning Review Incomplete Lydia Galbraith 6/5/2013 6/5/2013 3:33:20 PM Comment: THE MH IS IN FLOOD ZONE A AND REQUIRES A SIGNED AND SEALED FLOOD CERT FROM A FLORIDA LICENSED SURVEYOR. MIN.HEIGHT REQUIREMENTS FOR MH IS: "chassis is supported by reinforced piers or other foundation elements of at least an equivalent strength, of no less than thirty-six (36) inches in height above grade". SEE ST LUCIE COUNTY LAND DEVELOPMENT CODE CHAPTER 6.05.03 D. 10/4113 RECEIVED FLOOD CERT. MH IS NOT MEETING THE REQUIRED 36" TO CHASSIS ABOVE GRADE. 6/5/2013 3:33:20 PM Comment: PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING REVIEW. THE PLANS EXAMINER MIGHT HAVE ADDITIONAL COMMENTS. To be reviewed by Plans Complete 6/20/2013 6/5/2013 Examiner Comment: Environmental - Veg Permit Req Pending Audrey Humphrey 6/1112013 Comment: Plans Examiner Review Complete Dave Johnson 6/20/2013 1077/2013 Comment: PE Review Comments (2) Incomplete Dave Johnson 10/712013 9/26/2013 6/20/2013 3:29:12 PM Comment: PROVIDE 2 NEW WORKSHEETS WITH ALL PERTINENT INFO IE:PERMIT#,ADDRESS, DECAL#,SERIAL# ECT, WITH AN ORIGINAL SIGNITURE. 107.2.1 FBC—NOT ADDRESSED. STILL MISSING PERMIT #,COMPLETE ADDRESSED, DECAL #, WIND ZONE INFO 6/20/2013 3:30:33 PM Comment: PROVIDE INFO TO SHOW MH WILL MAINTAIN 70 DEGREES. HEAT LOAD CALLS IN ACCORDANCE WITH ASHRAE. 3280.506 MOBILE HOME CONSTRUCTION & SAFTEY STANDARDS' 10/7/13NOT ADDRESSED 6/20/2013 3:32:06 PM Comment: FOUNDATION MUST BE DESIGNED TO RESIST THE FORCES OF FLOOD. 6.1.5 MODEL MANUFACTURED HOME INSTALLATION STANDARDS.-10/7/13 NOT ADDRESSED 10/712013 3:26:20 PM Comment: ORIGINAL STEP DETAIL IS UNCLEAR. PLEASE PROVIDE LEGIBLE FIBERGLASS STEP DETAIL. 10/7/2013 3:28:56 PM Comment: COMMENTS ENTAILED TO CONTRACTOR MAILED TO OWNER Monday, October 07, 2013 3:29 PM Planning & Development Services Building &,Code.Regula0on Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462-2172 Fax:(7721462.6443 PROPERTY INFORMATION Address: 3318 Orange Ave 49 City / State /Zip: Fort Pierce, FI 34947 Parcel #: 2408-605-0007-000/4 Zoning: CG APPLICATION INFORMATION Permit Number: 1306-0047 Permit Type: Mobile Home REVIEW COMMENTS SCANNED BY 1 Owner(s): Seminole Mobil Park Lic Jurisdiction: St Lucie County Lot#: 8 Stories: Block: Automatic Sprinkler System? No Contractor Name: Lisa C Fasnacht Fax Number: 772-465-9003 Business Name: Lisa's Mobile Home Movers & Installers Inc Business Addr: 1708 St Lucie Ct Email: Water0662@Netpenny.Net City / State / Zip: Fort Pierce, FI 34949 REVIEWS AND COMMENTS Review. Type Status Reviewed By Date Started Date Completed Date Released Documents Missing Pending Audrey Humphrey 6/412013 6/4/2013 Comment: FILLED LANDS AFFIDAVIT 6/4/2013 Comment: VEGETATION PERMIT SUBMITTED TO ERD 6/4/2013 Comment: SUBMITTAL DOCUMENT FORM NOT SIGNED RETURNED TO RUNNER 6/52013 Comment: SUB AGREEMENTS WITH ORIGINAL SIGNATURE FOR ELECTRICAL, PLUMBING AND MECHANICAL (IF APPLICABLE) AND SUB SUMMARY SHEET Environmental - Vegetation Pending Audrey Humphrey 611112013 Comment: Environmental Review Complete Ben Balcer 611012013 6/4/2013 Front Counter Review Plans Examiner Review 6/20/2013 6/20/2013 6/20/2013 Comment: Complete Comment: Audrey Humphrey 61412013 6/412013 6/412013 Comment: PROVIDE 2 NEW WORKSHEETS WITH ALL PERTINENT INFO IE:PERMIT#,ADDRESS, DECAL#,SERIAL# ECT, WITH AN ORIGINAL SIGNITURE. 107.2.1 FBC Comment: 2000 PSI MAY NOT BE USED WITH READINGS OF 1800 & 1900. PLEASE CORRECT NEW WORKSHEET WHEN YOU RESUBMIT 15-C Comment: PROVIDE INFO TO SHOW MH W ILL MAINTAIN 70 DEGREES. HEAT LOAD CALC'S IN ACCORDANCE WITH ASHRAE. 3280.506 MOBILE HOME CONSTRUCTION & SAFTEY STANDARDS W L �„tirriio Planning & Development Services Building B.Code Regulation Division 2300 Virginla Avenue Fort Pierce, FL 34982 -Phone:(772)462.2172 Fax:(772)462.6443 REVIEW COMMENTS 2 Comment: HOME IS IN A FLOOD ZONE. FINISHED FLOOR AND ALL ELECTRIC PLUMBING AND MECHANICAL SYSTEMS 6/2012013 MUST BE ELEVATED ABOVE BASE FLOOD. 4.1.2 MODEL MANUFACTURED HOME INSTALLATION STANDARDS. Comment: FOUNDATION MUST BE DESIGNED TO RESIST THE FORCES OF FLOOD. 6.1.5 MODEL MANUFACTURED 6/20/2013 HOME INSTALLATION STANDARDS. 6/20/2013 Comment: PROVIDE LANDING/STAIR DETAILS 107.2.1 FBC 6/20/2013 Comment: COMMENTS EMAILED TO CONTRACTOR MAILED TO OWNER To be reviewed by Plans Examiner Complete 6/20/2013 61512013 Comment: To be reviewed by Zoning Complete 6/512013 61412013 Comment: Zoning Review Incomplete Lydia Galbraith 6/512013 6/5/2013 Comment: PLEASE PROVIDE 2 SIGNED AND SEALED MH INSPECTION REPORTS. Comment: MH WORKSHEET IS INCOMPLETE AND HAS NO SIGNATURES.PLEASE PROVIDE 2 NEWMHWORKSHEET, 6/5/2013 COMPLETELY FILLED OUT WITH ONE ORIGINAL SIGNATURE, ONE SIGNATURE MAYBE A COPY. Comment: THE MH IS IN FLOOD ZONE A AND REQUIRES A SIGNED AND SEALED FLOOD CERT FROM A FLORIDA 6/5/2013 LICENSED SURVEYOR. MIN.HEIGHT REQUIREMENTS FOR MH IS: "chassis is supported by reinforced piers or other foundation elements of at least an equivalent strength, of no less than thirty-six (36) inches in height above grade". SEE ST LUCIE COUNTY LAND DEVELOPMENT CODE CHAPTER 6.05.03 D. Comment: PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING REVIEW. THE PLANS 6/5/2013 EXAMINER MIGHT HAVE ADDITIONAL COMMENTS.