HomeMy WebLinkAboutENERGY EFFICIENCY CODERNUVE,%T_
FEB 15 2019
FILE COPY
FORM R405-2017
ST. Lucle County,
FLORIDA ENER ODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MW-286
Builder Name: GHO HOMES
Street: 9431 MEADOWOOD
DR
Permit Office: ST. LUCIE COUNTY BLDG DPTMNT
City, State, Zip: FORT PIERCE, FL, 34951
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
9. Wall Types (3008.9 sgft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.0 2760.00 fit'
b. Frame -Wood, Adjacent
R=11.0 248.89 ft2
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
3
d. N/A
R= ft2
10. Ceiling Types (2987.0 sqft.)
Insulation Area
5. Is this a worst case?
No
a. Under Attic (Vented)
R=30.0 2987.00 ft 2
6. Conditioned floor area above grade (11:2)
2987
b. N/A
R= ft2
Conditioned floor area below grade (ft2)
0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(530.7 sgft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: Main
6 298
a. U-Factor: Dbl, U=0.50
514.67 ft2
SHGC: SHGC=0.26
b. U-Factor: Gbl, default
16.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: Clear, default
a. Central Unit sC
66.0 SEER:16.00
_- - c. N/A
ft2
sf
,'A1�'
SHGCU-Factor.
SHGC:
13. Heating systems �4 �'V,V%/hr
0/0
Efficiency
d. U-Factor: N/A
SHGC:
ft2
a. Electric Strip Heat
CO
42.0 COP:1.00
Area Weighted Average Overhang Depth:
0.000 ft.
%611
Area Weighted Average SHGC:
0.269
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (2987.0 sgft.)
Insulation Area
EF: 0.900
a. Slab -On -Grade Edge Insulation
R=D.O 2987.00 f12
b. Conservation features
b. N/A
R= ft2
None
c. N/A
R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.178
Total Proposed Modified Loads: 89.19
PASS
Total Baseline
Loads: 95.32
-1 hereby certify that the plans and specifications covered by
Review of the plans and
STA?A
this calculatio re in c mpliance with the Florida Energy
specifications covered by this
0,,V%E
Code.
calculation indicates compliance''-'
10
with the Florida Energy Code.
nrrr••-. •`ia;;` ��
PREPARED Y:
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
'$�i, n ,a
c
I hereby certify that
, is in compliance
Florida Statutes.
COD
with the Florid nergy ode.
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
"• Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factorysealed in accordance with R403.3.2.1.
-- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
1/17/2019 11:01 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
_ #_of Units. -
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
MW-286 Bedrooms: 3
User Conditioned Area: 2987
Total Stories: 1
].—_ - _ _ __ _ _ _ _ _ —Worst-Case: No- - --
GHO HOMES Rotate Angle: 0
ST. LUCIE COUNTY BLDG D Cross Ventilation: No
Whole House Fen: No
Single-family
New (From Plans)
Address Type: Street Address
Lot #
Block/Subdivision: -
PlatBook: -- - -
Street: 9431 MEADOWOOD D
County: St. Lucie
City, State, Zip: FORT PIERCE,
FL, 34951
-{
CLIMATE
x _ /
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO_SEACH_MUNI 39 90
70
75. 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
2987 27779.1
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled Heated
1
Main
2987 27779.1 Yes 4
3
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 259.7 ft 0
2987 fl'
---- 0 0 1
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt Emil Deck Pitch
Tested Tested Insul. (deg)
1
Hip
Barrel the 3341 ft' 0 ft' Medium
0.4
N 0.9 No 0 26.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 In)
Area
RBS IRCC
1
Full attic
Vented 150 2987 ft'
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Free Truss Type
1
Under Attic (Vented)
Main 30 Blown
2987 ft' 0.1 Wood
tr
1/17/2019 11:01 AM
EnergyGauge® USA Section R405.4.1 Compliant Software
Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
ace S
p
Cavity
Width Height
Sheathing Framing
Solar
Below
mL
Tn
Wall
Type
R-Vag a
Ft
In F-t--Jn
Oren
R-Valtip._Fraction-Absor_-Gra
°
_ 1
N
Exterior
Concrete
Block - Ext Insul
Main
4
9
3 10
0
92.5 ft2
0
0
0.3
0
_ 2-
--NE--Exterior--Concrete-Block-Ext
lnsul-Main---
-- 4-
- -79
-0- 10
-0--
790.0 ftl-
--0-
-0-- -
-0..3--
- -0 -
3
BE
Exterior
Concrete
Block - Ext Insul
Main
4
41
7 10
0
415.8 ft2
0
0
0.3
0
_ 4
SW
Exterior
Concrete Block - Ext Insul
Main
4
82
7 10
0
825.8 ft2
0
0
0.3
0
-5
W
Exterior
Concrete
Block - Ext Insul
Main
4
4
3 10
0
42.5 ft2
0
0
0.3
0
-6
NW
Exterior
Concrete Block - Ext Insul
Main
4
59
4 10
0
593.3 ft-
0
0
0.3
0
7
-
Garage
Frame - Wood
Main
11
26
8 9
4
248.9 ft-
0
0.25
0.3
0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
NE
Wood Main
None
.39
2
8
8
21.3 ft-
2
BE
Wood Main
None
.39
6
8
48 112
i
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Ornt ID
Frame
Panes NFRC
U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
n 1
Metal
Double (Clear)
Yes
0.5
0.26
N
24.7 ft2
0 ft 0 in
0 It 0 in
None
None
2
ne 2
Metal
Double (Clear)
Yes
0.5
0.26
N
8.0 ft2
0 It 0 in
0 ft 0 in
None
None
_
3
ne 2
Metal
Double (Clear)
Yes
0.5
0.26
N
9.0 ft2
0 ft 0 in
0 ft 0 in
None
None
4
ne 2
Metal
Double (Clear)
Yes
0.5
0.26
N
12.0 ft2
0 ft 0 in
0 ft 0 in
None
None
5
ne 2
Metal
Double (Clear)
Yes
0.5
0.26
N
21.3 R2
0 ft 0 in
0 ft 0 in
None
None
6
ne 2
Metal
Double (Clear)
Yes
0.5
0.26
N
24.0 ft2
0 It 0 in
0 ft 0 in
None
None
_
7
se 3
Metal
Double (Clear)
Yes
0.5
0.26
N
18.0 ft-
0 ft 0 in
0 ft 0 in
None
None
8
se 3
Metal
Double (Clear)
Yes
0.5
0.26
N
12.0 ft-
0 It 0 in
0 It 0 in
None
None
9
se 3
Metal
Double (Clear)
Yes
0.5
0.26
N
26.0 ft2
0 ft 0 in
0 It 0 in
None
None
10
se 3
None
Glazed Block
No
0.6
0.57
N
16.0 ft2
0 ft 0 in
0 ft 0 in
None
None
11
sw 4
Metal
Double (Clear)
Yes
0.5
0.26
N
8.0 ft2
0 ft 0 in
0 It 0 in
None
None
12
sw 4
Metal
Double (Clear)
Yes
0.5
0.26
N
30.0 ft2
0 It 0 in
0 ft 0 in
None
None
13
sw 4
Metal
Double (Clear)
Yes
0.5
0.26
N
9.0 ft2
0 ft 0 in
0 It 0 in
None
None
14
sw 4
Metal
Double (Clear)
Yes
0.5
0.26
N
24.0 ft-
0 It 0 In
0 It 0 in
None
None
15
w 5
Metal
Double (Clear)
Yes
0.5
0.26
N
18.7 ft2
0 ft 0 in
0 It 0 in
None
None
16
nw 6
Metal
Double (Clear)
Yes
0.5
0.26
N
36.0 ftz
0 ft 0 in
0 ft 0 in
None
None
17
nw 6
Metal
Double (Clear)
Yes
0.5
0.26
N
96.0 ft2
0 ft 0 in
0 ft 0 in
None
None
18
nw 6
Metal
Double (Clear)
Yes
0.5
0.26
N
18.0 ft2
0 It 0 in
0 It 0 in
None
None
19
NW 6
Metal
Double (Clear)
Yes
0.5
0.26
N
120.0 ftz
0 ft 0 in
0 ft 0 in
None
None
1/17/2019 11:01 AM
EnergyGauge® USA Section R405.4.1 Compliant Software
Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height
Exposed Wall Insulation
1
700 ft2
700 ft2
64 ft
9.3 ft
1
- - -
- - --
- -INFILTRATION —
-
- - -
-' # Scope
Method
SLA
CFM 50 ELA EgLA
ACH
ACH 50
,1 Wholehouse
Proposed ACH(50)
.000295
2314.9 127.09 239
.224
5
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric
None
Garage
0.9 50 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cent #
Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ft2
DUCTS
/ —Supply--
V # Location R-Value Area
--Return--
Location Area Leakage Type
Air
Handler
CFM 25
TOT
CFM25
OUT ON
RLF
HVAC#
Heat Cool'
1 A
1 B
Attic
Attic
6 504 ft2
6 298 ft2
Attic
Attic
251 ft2 Default Leakage
189 ft2 Default Leakage
Main
Main
(Default) (Default)
(Default) (Default)
1 1
1 1
TEMPERATURES
Programablfe'Thermostat:
'JY
Heating l l Jan l l Feb
_ Venting 11 Jan 11 Feb
H Mar
X Mar
CAprr[eiling Fans: uj
Apr [ I May 11 Jun JMay Jun ul
[DC
[ Aug
fr
[ Sep
Oct
NovfX't
Nov
iOct Dec
[ ] Dec
Thermostat Schedule:
Schedule Type
HERS 2006 Reference
1
2 3
Hours
4 5 6
7
8
9 10
11
12
"'Cooling (WD)
Cooling (WEH)
Heating (WD)
Heating (WEH)
AM
PM
AM
PM
AM
PM
AM
PM
78
80
78
78
66
68
66
68
78 78
80 78
78 78
78 78
66 66
68 68
66 66
68 68
78 78 78
78 78 78
78 78 78
78 78 78
66 66 68
68 68 68
66 66 68
68 68 68
78
78
78
78
68
68
68
68
78
78
78
78
68
68
68
68
80 80
78 78
78 78
78 78
68 68
68 68
68 68
68 68
80
78
78
78
68
66
68
66
80
78
78
78
68
66
68
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft2
0 ft
0.3
Main
Name:
Rating Compant:
Signature:
Date:
1/17/2019 11:01 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4
4-
Y
2017 EPL DISPLAY CARD,
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the Energy Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 3
13. Coaling system: Capacity
66.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned Floor area (sq. ft.)
6. 2987
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.503
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.269
14. Heating system: Capacity
42.0
c) Area
7c. 530.7
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised-(R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.90
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2. 4.0
0 Heat recovery unit HeatRec%
- B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
1081. 11.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level a) Ceiling fans
a) Under attic 11a. 30.0 b) Cross ventilation No
b) Single assembly 11b. c) Whole house fan No
c) Knee walls/skylight walls 11c, d) Multizone cooling credit
d) Radiant barrier installed 11d. No e) Multizone heating credit
9 Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed bas d on installed code compliant features.
Address of New Home:
City/FL Zip: FORT PIERCE, FL 34951
1/17/2019 11:01:53 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
+�- wrightsoft-. Load Short Form
Entire House
Project Information
For: MW-266
3012 BENT PINE DR, FORT PIERCE, FL 34951
Job:
Date: Dec 26, 2018
By:
Design Information
Htg Clg Infiltration
Outsidedb (°F) 43 90 Method Simplified
Inside db (°F) 70 72 Construction quality Tight
Design TD (°F) 27 18 Fireplaces 0
Daily range - L
Inside humidity (°/a) 30 50
Moisture difference (gr/lb) 0 68
HEATING EQUIPMENT
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
100 EFF
8.6
kW
29480
Btuh
17
OF
1550
cfm
0.049
cfm/Btuh
0
in H2O
COOLING EQUIPMENT
Make Carrier
Trade 16 SEER PURON AC
Cond CA16NA048••"A
Coil FV4CNB006
AHRI ref 4585139
Efficiency 14.0 EER,
Sensible cooling
Latent cooling
Total cooling
Actual air Flow
Air flow factor
Static pressure
Load sensible heat ratio
16 SEER
32550
Btuh
13950
Btuh
46500
Btuh
1550
cfm .
0.045
cfm/Btuh
0
in H2O
0.73
ROOM NAME
Area
(ft') .
Htg load
(Btuh)
Cig load
(Btuh)
Htg AVF
(cfm)
Clg AVF
(Cfm)
MASTER SUITE
405
5926
5927
293
268
HER WIC
86
1240
731
61
33
HIS WIC
44
47
235
2
11
GREAT ROOM
423
4611
5344
228
242
DINING
159
3040
5710
150
258
FOYER
57
1275
1710
63
77
NOOK
144
3015
2630
149
119
KIT
210
221
1689
11
76
BED 3
149
1620
1629
80
74
BED3WIC
33
1065
616
53
28
CABANA
76
1319
717
65
32
BED 2
188
1869
1760
92
80
BATH 2
59
1037
643
51
29
UTI
—
YF7—
92—
31
MECH
34
462
624
23
28
MA.QTFR RATW
044
aeon
oem
one
r.. 1VLV VVVL LGl IVJ
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2018-Dec-27 09:42:34
t wrightSOW RlghtSulte® Universal 201212.1.05 RSU02818 Pagel
x CAUsersUason\DocumentslWAghtsoft HVAC\MW-266.rup Cale =MJ8 Front Door laces: W
Entire House
2327
31394
34260
1550
1550
Other equip loads
0
0
Equip. @ 0.95 RSM
32547
Latent cooling
12868
TCITGI Si
I AI A.,
I
I
I_y_J_V_ _IUUV
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2018-Deo-2709:42:34
!!tiwrightSOW Rig htSuitcV Universal 201212.1.05 RSU02818 Page
)m C:1UsemsJason%Documents%WHghtsoft FIVACNIV-286.rup Cato =MJ8 Front Door/ams: W
- wrightsoft- Project Summary
Entire House
Project Information
For: MW-266
3012 BENT PINE DR, FORT PIERCE, FL 34951
Notes:
Job:
Date: Dec 26, 2018
By:
Design Information
Vero Beach, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 43
OF
Outside db
90
OF
Inside db 70
OF
Inside db
72
OF
Design TD 27
OF
Design TD
18
OF
Daily range
L
Relative humidity
50
%
Moisture difference
68
gr/lb
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure 25742
Btuh
Structure
27271
Btuh
Ducts 5652
Btuh
Ducts
6989
Btuh
Central vent (0 cfm) 0
Btuh
Central vent (0 cfm)
0
Btuh
Humidification 0
Btuh
Blower
0
Btuh
Piping 0
Btuh
Equipment load 31394
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Infiltration
Equipment sensible load
32547
Btuh
Method Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Tight
Fireplaces
0
Structure
10593
Btuh
Ducts
2275
Btuh
Heating
Cooling
Central vent (0 cfm)
0
Btuh
Area (ft') 2327
2327
Equipment latent load
12868
Btuh
Volume (ft) 23687
23687
Air changes/hour 0.11
0.06
Equipment total load
45415
Btuh
Equiv. AVF (cfm) 43
24
Req. total capacity at 0.70 SHR
3.9
ton
Heating Equipment Summary Cooling Equipment Summary
Make
Make Carrier
Trade
Trade 16 SEER PURON AC
Model
Cond CA16NA048""A
AHRI ref
Coil FV4CNB006
AHRI ref 4585139
Efficiency
100 EFF
Efficiency 14.0 EER,
16 SEER
Heating input
8.6
kW
Sensible cooling
32550
Btuh
Heating output
29480
Btuh
Latent cooling
13950
Btuh
Temperature rise
17
OF
Total cooling
46500
Btuh
Actual air flow
1550
cfm
Actual air flow
1550
cfm
Air flow factor
0.049
cfm/Btuh
Air flow factor
0.045
cfm/Btuh
Static pressure
U
in H20
Static pressure
0
in H2O
Space thermostat
Load sensible heat ratio
0.73
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrl htsoft- 2018-Dec-2709:42:34
g Rig htSuite® U niversal 201212.1.05 RSU02818 Paget
�'� C:1UsersUasontDocumentslWrightsoft HVAC\MW-266.rup Cato =MJ8 Front Door faces: W
DONOTSC PI S
GHO HOMES
MW-266
3012 SENT PINE X
FORT PIERCE, FL 34951