Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODERNUVE,%T_ FEB 15 2019 FILE COPY FORM R405-2017 ST. Lucle County, FLORIDA ENER ODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MW-286 Builder Name: GHO HOMES Street: 9431 MEADOWOOD DR Permit Office: ST. LUCIE COUNTY BLDG DPTMNT City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (3008.9 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.0 2760.00 fit' b. Frame -Wood, Adjacent R=11.0 248.89 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (2987.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2987.00 ft 2 6. Conditioned floor area above grade (11:2) 2987 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(530.7 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 298 a. U-Factor: Dbl, U=0.50 514.67 ft2 SHGC: SHGC=0.26 b. U-Factor: Gbl, default 16.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: Clear, default a. Central Unit sC 66.0 SEER:16.00 _- - c. N/A ft2 sf ,'A1�' SHGCU-Factor. SHGC: 13. Heating systems �4 �'V,V%/hr 0/0 Efficiency d. U-Factor: N/A SHGC: ft2 a. Electric Strip Heat CO 42.0 COP:1.00 Area Weighted Average Overhang Depth: 0.000 ft. %611 Area Weighted Average SHGC: 0.269 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2987.0 sgft.) Insulation Area EF: 0.900 a. Slab -On -Grade Edge Insulation R=D.O 2987.00 f12 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.178 Total Proposed Modified Loads: 89.19 PASS Total Baseline Loads: 95.32 -1 hereby certify that the plans and specifications covered by Review of the plans and STA?A this calculatio re in c mpliance with the Florida Energy specifications covered by this 0,,V%E Code. calculation indicates compliance''-' 10 with the Florida Energy Code. nrrr••-. •`ia;;` �� PREPARED Y: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 '$�i, n ,a c I hereby certify that , is in compliance Florida Statutes. COD with the Florid nergy ode. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: "• Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factorysealed in accordance with R403.3.2.1. -- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 1/17/2019 11:01 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: _ #_of Units. - Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: MW-286 Bedrooms: 3 User Conditioned Area: 2987 Total Stories: 1 ].—_ - _ _ __ _ _ _ _ _ —Worst-Case: No- - -- GHO HOMES Rotate Angle: 0 ST. LUCIE COUNTY BLDG D Cross Ventilation: No Whole House Fen: No Single-family New (From Plans) Address Type: Street Address Lot # Block/Subdivision: - PlatBook: -- - - Street: 9431 MEADOWOOD D County: St. Lucie City, State, Zip: FORT PIERCE, FL, 34951 -{ CLIMATE x _ / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_SEACH_MUNI 39 90 70 75. 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 2987 27779.1 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 2987 27779.1 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 259.7 ft 0 2987 fl' ---- 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Emil Deck Pitch Tested Tested Insul. (deg) 1 Hip Barrel the 3341 ft' 0 ft' Medium 0.4 N 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 In) Area RBS IRCC 1 Full attic Vented 150 2987 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) Main 30 Blown 2987 ft' 0.1 Wood tr 1/17/2019 11:01 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent ace S p Cavity Width Height Sheathing Framing Solar Below mL Tn Wall Type R-Vag a Ft In F-t--Jn Oren R-Valtip._Fraction-Absor_-Gra ° _ 1 N Exterior Concrete Block - Ext Insul Main 4 9 3 10 0 92.5 ft2 0 0 0.3 0 _ 2- --NE--Exterior--Concrete-Block-Ext lnsul-Main--- -- 4- - -79 -0- 10 -0-- 790.0 ftl- --0- -0-- - -0..3-- - -0 - 3 BE Exterior Concrete Block - Ext Insul Main 4 41 7 10 0 415.8 ft2 0 0 0.3 0 _ 4 SW Exterior Concrete Block - Ext Insul Main 4 82 7 10 0 825.8 ft2 0 0 0.3 0 -5 W Exterior Concrete Block - Ext Insul Main 4 4 3 10 0 42.5 ft2 0 0 0.3 0 -6 NW Exterior Concrete Block - Ext Insul Main 4 59 4 10 0 593.3 ft- 0 0 0.3 0 7 - Garage Frame - Wood Main 11 26 8 9 4 248.9 ft- 0 0.25 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NE Wood Main None .39 2 8 8 21.3 ft- 2 BE Wood Main None .39 6 8 48 112 i WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 n 1 Metal Double (Clear) Yes 0.5 0.26 N 24.7 ft2 0 ft 0 in 0 It 0 in None None 2 ne 2 Metal Double (Clear) Yes 0.5 0.26 N 8.0 ft2 0 It 0 in 0 ft 0 in None None _ 3 ne 2 Metal Double (Clear) Yes 0.5 0.26 N 9.0 ft2 0 ft 0 in 0 ft 0 in None None 4 ne 2 Metal Double (Clear) Yes 0.5 0.26 N 12.0 ft2 0 ft 0 in 0 ft 0 in None None 5 ne 2 Metal Double (Clear) Yes 0.5 0.26 N 21.3 R2 0 ft 0 in 0 ft 0 in None None 6 ne 2 Metal Double (Clear) Yes 0.5 0.26 N 24.0 ft2 0 It 0 in 0 ft 0 in None None _ 7 se 3 Metal Double (Clear) Yes 0.5 0.26 N 18.0 ft- 0 ft 0 in 0 ft 0 in None None 8 se 3 Metal Double (Clear) Yes 0.5 0.26 N 12.0 ft- 0 It 0 in 0 It 0 in None None 9 se 3 Metal Double (Clear) Yes 0.5 0.26 N 26.0 ft2 0 ft 0 in 0 It 0 in None None 10 se 3 None Glazed Block No 0.6 0.57 N 16.0 ft2 0 ft 0 in 0 ft 0 in None None 11 sw 4 Metal Double (Clear) Yes 0.5 0.26 N 8.0 ft2 0 ft 0 in 0 It 0 in None None 12 sw 4 Metal Double (Clear) Yes 0.5 0.26 N 30.0 ft2 0 It 0 in 0 ft 0 in None None 13 sw 4 Metal Double (Clear) Yes 0.5 0.26 N 9.0 ft2 0 ft 0 in 0 It 0 in None None 14 sw 4 Metal Double (Clear) Yes 0.5 0.26 N 24.0 ft- 0 It 0 In 0 It 0 in None None 15 w 5 Metal Double (Clear) Yes 0.5 0.26 N 18.7 ft2 0 ft 0 in 0 It 0 in None None 16 nw 6 Metal Double (Clear) Yes 0.5 0.26 N 36.0 ftz 0 ft 0 in 0 ft 0 in None None 17 nw 6 Metal Double (Clear) Yes 0.5 0.26 N 96.0 ft2 0 ft 0 in 0 ft 0 in None None 18 nw 6 Metal Double (Clear) Yes 0.5 0.26 N 18.0 ft2 0 It 0 in 0 It 0 in None None 19 NW 6 Metal Double (Clear) Yes 0.5 0.26 N 120.0 ftz 0 ft 0 in 0 ft 0 in None None 1/17/2019 11:01 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 700 ft2 700 ft2 64 ft 9.3 ft 1 - - - - - -- - -INFILTRATION — - - - - -' # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 ,1 Wholehouse Proposed ACH(50) .000295 2314.9 127.09 239 .224 5 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.9 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cent # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / —Supply-- V # Location R-Value Area --Return-- Location Area Leakage Type Air Handler CFM 25 TOT CFM25 OUT ON RLF HVAC# Heat Cool' 1 A 1 B Attic Attic 6 504 ft2 6 298 ft2 Attic Attic 251 ft2 Default Leakage 189 ft2 Default Leakage Main Main (Default) (Default) (Default) (Default) 1 1 1 1 TEMPERATURES Programablfe'Thermostat: 'JY Heating l l Jan l l Feb _ Venting 11 Jan 11 Feb H Mar X Mar CAprr[eiling Fans: uj Apr [ I May 11 Jun JMay Jun ul [DC [ Aug fr [ Sep Oct NovfX't Nov iOct Dec [ ] Dec Thermostat Schedule: Schedule Type HERS 2006 Reference 1 2 3 Hours 4 5 6 7 8 9 10 11 12 "'Cooling (WD) Cooling (WEH) Heating (WD) Heating (WEH) AM PM AM PM AM PM AM PM 78 80 78 78 66 68 66 68 78 78 80 78 78 78 78 78 66 66 68 68 66 66 68 68 78 78 78 78 78 78 78 78 78 78 78 78 66 66 68 68 68 68 66 66 68 68 68 68 78 78 78 78 68 68 68 68 78 78 78 78 68 68 68 68 80 80 78 78 78 78 78 78 68 68 68 68 68 68 68 68 80 78 78 78 68 66 68 66 80 78 78 78 68 66 68 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main Name: Rating Compant: Signature: Date: 1/17/2019 11:01 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4 4- Y 2017 EPL DISPLAY CARD, ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Coaling system: Capacity 66.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned Floor area (sq. ft.) 6. 2987 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.503 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.269 14. Heating system: Capacity 42.0 c) Area 7c. 530.7 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised-(R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.90 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.0 0 Heat recovery unit HeatRec% - B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1081. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c, d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit 9 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed bas d on installed code compliant features. Address of New Home: City/FL Zip: FORT PIERCE, FL 34951 1/17/2019 11:01:53 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 +�- wrightsoft-. Load Short Form Entire House Project Information For: MW-266 3012 BENT PINE DR, FORT PIERCE, FL 34951 Job: Date: Dec 26, 2018 By: Design Information Htg Clg Infiltration Outsidedb (°F) 43 90 Method Simplified Inside db (°F) 70 72 Construction quality Tight Design TD (°F) 27 18 Fireplaces 0 Daily range - L Inside humidity (°/a) 30 50 Moisture difference (gr/lb) 0 68 HEATING EQUIPMENT Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 8.6 kW 29480 Btuh 17 OF 1550 cfm 0.049 cfm/Btuh 0 in H2O COOLING EQUIPMENT Make Carrier Trade 16 SEER PURON AC Cond CA16NA048••"A Coil FV4CNB006 AHRI ref 4585139 Efficiency 14.0 EER, Sensible cooling Latent cooling Total cooling Actual air Flow Air flow factor Static pressure Load sensible heat ratio 16 SEER 32550 Btuh 13950 Btuh 46500 Btuh 1550 cfm . 0.045 cfm/Btuh 0 in H2O 0.73 ROOM NAME Area (ft') . Htg load (Btuh) Cig load (Btuh) Htg AVF (cfm) Clg AVF (Cfm) MASTER SUITE 405 5926 5927 293 268 HER WIC 86 1240 731 61 33 HIS WIC 44 47 235 2 11 GREAT ROOM 423 4611 5344 228 242 DINING 159 3040 5710 150 258 FOYER 57 1275 1710 63 77 NOOK 144 3015 2630 149 119 KIT 210 221 1689 11 76 BED 3 149 1620 1629 80 74 BED3WIC 33 1065 616 53 28 CABANA 76 1319 717 65 32 BED 2 188 1869 1760 92 80 BATH 2 59 1037 643 51 29 UTI — YF7— 92— 31 MECH 34 462 624 23 28 MA.QTFR RATW 044 aeon oem one r.. 1VLV VVVL LGl IVJ Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Dec-27 09:42:34 t wrightSOW RlghtSulte® Universal 201212.1.05 RSU02818 Pagel x CAUsersUason\DocumentslWAghtsoft HVAC\MW-266.rup Cale =MJ8 Front Door laces: W Entire House 2327 31394 34260 1550 1550 Other equip loads 0 0 Equip. @ 0.95 RSM 32547 Latent cooling 12868 TCITGI Si I AI A., I I I_y_J_V_ _IUUV Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Deo-2709:42:34 !!tiwrightSOW Rig htSuitcV Universal 201212.1.05 RSU02818 Page )m C:1UsemsJason%Documents%WHghtsoft FIVACNIV-286.rup Cato =MJ8 Front Door/ams: W - wrightsoft- Project Summary Entire House Project Information For: MW-266 3012 BENT PINE DR, FORT PIERCE, FL 34951 Notes: Job: Date: Dec 26, 2018 By: Design Information Vero Beach, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 90 OF Inside db 70 OF Inside db 72 OF Design TD 27 OF Design TD 18 OF Daily range L Relative humidity 50 % Moisture difference 68 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 25742 Btuh Structure 27271 Btuh Ducts 5652 Btuh Ducts 6989 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 31394 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 32547 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 0 Structure 10593 Btuh Ducts 2275 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft') 2327 2327 Equipment latent load 12868 Btuh Volume (ft) 23687 23687 Air changes/hour 0.11 0.06 Equipment total load 45415 Btuh Equiv. AVF (cfm) 43 24 Req. total capacity at 0.70 SHR 3.9 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade 16 SEER PURON AC Model Cond CA16NA048""A AHRI ref Coil FV4CNB006 AHRI ref 4585139 Efficiency 100 EFF Efficiency 14.0 EER, 16 SEER Heating input 8.6 kW Sensible cooling 32550 Btuh Heating output 29480 Btuh Latent cooling 13950 Btuh Temperature rise 17 OF Total cooling 46500 Btuh Actual air flow 1550 cfm Actual air flow 1550 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure U in H20 Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.73 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrl htsoft- 2018-Dec-2709:42:34 g Rig htSuite® U niversal 201212.1.05 RSU02818 Paget �'� C:1UsersUasontDocumentslWrightsoft HVAC\MW-266.rup Cato =MJ8 Front Door faces: W DONOTSC PI S GHO HOMES MW-266 3012 SENT PINE X FORT PIERCE, FL 34951