Loading...
HomeMy WebLinkAboutCERTIFICATION - DESIGN LOAD COMPLIANCEi FI Lin ve rvices Department B. Re lotions Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Project Address: Permit Occupancy Type: Construction Type: �E�€:rm ink c_oLnt LM INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. ' Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the 4 above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (comps to all that apply) 1. DESIGN CODE: Florida 2017 Building Code Edition with 20 N/A Supplements using ASCE 7-10 2. Structure Designed as (check one): x Enclosed _Partially Enclosed _Open 3. Risk Category: _I x II _III _ IV Exposure Category: _B x C _D 4. Design Wind Velocity t60 mph X ASD _LRFD End Zone Width: 6 ft 5. Mean Roof Height I � ft Roof Pitch: 6 :12 Parapet: N/A ft 6. Components & Gadding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, dearly label on all plan openings): i 1�.O f -r9 a 2D.O f 3�li t3y.� +e& Zone:-.4j-F Zone2:^53.3 Zone3:—:Vl.'�L Zone4:^3i46 Zones: Garage: - 3/• 7. Design Loads: Floor. 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: WA PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF B. Were Shear Walls Considered ForStructure3 _Yes )(_Not Applicable Explain Why Not: .�SPr3G1 A&vi 0 , f: l 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design Mcwm . 'vvgzo J Na6/ is Print Name Cert # & Co. Cert Auth. /[ C 3 e/ 5V 1z.0LUCw,+ -GM/ h Company Name & Address Revised