HomeMy WebLinkAboutENERGY EFFICIENCY CODERECEIVED
FORM R405-2017 FEB 15 2019
FLORIDA ENERGY EFFICIENCY CODE FOR SURc."DWO I@QNS TRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 96
Builder Name: GHO HO
Street: 9623 KNOLLWOOD LN
Permit Office: ST LUCI I ILGDCNTC®PY
City, State, Zip: FORT PIERCE, FL, 34951
Permit Number:
Owner:
Jurisdiction:
_
Design Location: FL, ST_LUCIE_CO_INTL
County: st. lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types(2422.7 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.0 2127.10 ft2
b. -Wood, Adjacent
R=11.0 295.61 ft2
3.1 Number of units, if multiple family 1
c. N/Ame
R= ft2
4.;Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (2389.0 sqft.)
Insulation' Area
a. Under Attic (Vented)
R=30.0 2389.00 ft=
6. Conditioned floor area above grade (ft2) 2389
b. N/A
R= ft'
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft'
7. Windows(450.3 sqft.) Description Area
a. Sup: Attic, Rat: Attic, AH: Main
6 697
a. U-Factor: Dbl, U=0.62 450.28 ft2
SHGC: SHGC=0.26
b.'U-Factor: N/A ft2
12. Cooling systems
kBtu(hr Efficiency
SHGC:
a. Central Unit
48.0 SEER:16.00
- c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
.d. U-Factor: NIA ft2
�7
a. Electric Strip Heat
29.5 COP:1.00
r}},� SHGC:
wt aaWeighted Average Overhang Depth: ' 0.000 ft.
.9rea Weighted Average SHGC: 0.260
14. Hot waters stems
Y
8.-Floor Types (2389.0 sgft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 2389.00 ft2
b. Conservation features
EF: 0.940
ti. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pslat
Glass/Floor Area: 0,188 Total Proposed Modified Loads: 77.98
PASS
Total Baseline Loads: 78.03
'I hereby certify that the plans and specifications covered by
Review of the plans and
ST,gr�
this calculation a in Iiance with the Florida Energy
specifications covered by this
OF•Slie
ti , , _ s , O
Code.
calculation indicates compliance
with the Florida Energy Code.
�. nrn.'••%.:aii.+;:.'�,� O
PREPARED B :
Before construction is completed
` DATE: -I
this building will be inspected for
compliance with Section 553.908
t „
I hereby certify that i g, as design is in compliance
Florida Statutes.
with the Florid ner od
C01)
-OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
•- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with_R402.4.1..1_and_this_ ro'ect.requires_an
no greater than 5.00 ACH50 (R402.4.1.2).
E
SCANNED
BY
St. Lucie County
1/17/2019 10:43 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 5
190�-03/�
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units: _
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
MW-05 Bedrooms: 3
User Conditioned Area: 2389
Total Stories: 1
_ 1 _ _Worst. Case:. No.
GHO HOMES Rotate Angle: 0
ST LUCIE BUILDING DPTMN Cross Ventilation: No
Whole House Fan: No
Single-family
New (From Plans)
Address Type:
Lot#
Block/Subdivision:
PlatBook:. - - -
Street:
County:
City, State, Zip:
Street Address
-
9623 KNOLLWOOD LN
St. lucie
FORT PIERCE,
FL, 34951
CLIMATE
_ /
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
T FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70
75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
2389 22217.7
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfI ID Finished Cooled Heated
" 1
Main
2389 22217.7 Yes 4
3
1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 215.9 It 0
2389 ft'
0 0 1
ROOF
V #
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt
Tested
Emilt Deck Pilch
Tested Insul. (deg)
1
Hip
Concrete 2672 It' 0 ft' Medium
0.4
N 0.9
No 0 26.6
ATTIC
/
' V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 2389 ft'
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Free Truss Type
1
Under Attic (Vented)
Main 30 Blown
2389 f1' 0.1
Wood
-1/1712019 10:43 AM
3= c
EnergyGauge® USA Section R405.4.1 Compliant Software
Page 2 of 5
FORM
WALLS
Adjacent
S Pace
Cavity
Width
Height
Sheathing Framing
Solar
Below
-lJillt
Tn
WaILTypa
R-value
Fr
in
Ft
rn
Area R_value-F1aC8on_._AbSorrGrada%_
_ 1
N
Exterior
Concrete Block- EM Insul
Main
4
32
0
11
4
362.7 ft'
0
0
0.3
0
-2
NE,
-Exterior
Concrete Block -.Ext.lnsul-Main
4
2
11-1.1_
4
33.1 M
0
0
0.3
0-
3
E
Exterior
Concrete Block- Ext Insul
Main
4
55
11
9
4
521.9 ft'
0
0
0.3
0
4
BE
Exterior
Concrete Block - EM Insul
Main
4
8
7
11
4
97.3 ft-
0
0
0.3
0
_ 5
,--5
S
Exterior
Concrete Block - EM Insul
Main
4
58
2
9
4
542.9 ft-
0
0
0.3
0
-6
W
Exterior
Concrete Block - Exl Insul
Main
4
61
0
9
4
569.3 ft'
0
0
0.3
0
7
-
Garage
Frame - Wood
Main
11
26
1
11
4
295.6 ft2
0
0.25
0.3
0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Wood Main
None
.39
3
8
24 ft'
WINDOWS
-_ ./
Wall
Overhang
V #
Ornt
ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Inl Shade
Screening
_ 1
n
1
Metal
Double (Clear)
Yes
0.62
0.26
N
48.0 ft-
0 ft 0 in
0 ft 0 in
None
None
2
n
1
Metal
Double (Clear)
Yes
0.62
0.26
N
8.0 112
0 ft 0 in
0 ft 0 in
None
None
3
n
1
Metal
Double (Clear)
Yes
0.62
0.26
N
8.0 ft2
0 ft 0 in
0 ft 0 in
None
None
4
n
1
Metal
Double (Clear)
Yes
0.62
0.26
N
21.7 ft2
0 ft 0 in
0 ft 0 in
None
None
5
ne
2
Metal
Double (Clear)
Yes
0.62
0.26
N
16.0 ft2
0 ft 0In
0 ft 0 In
None
None
6
e
3
Metal
Double (Clear)
Yes
0.62
0.26
N
21.3 ft2
0 ft 0 In
0 ft 0 in
None
None
7
e
3
Metal
Double (Clear)
Yes
0.62
0.26
N
6.5 112
0 ft 0 In
0 ft 0 in
None
None
_ 8
e
3
Metal
Double (Clear)
Yes
0.62
0.26
N
12.0 ft2
0 ft 0 in
0 ft 0 in
None
None
9
se
4
Metal
Double (Clear)
Yes
0.62
0.26
N
20.0 ft'
0 ft 0 In
0 ft 0 in
None
None'
10
se
4
Metal
Double (Clear)
Yes
0.62
0.26
N
21.3 112
0 ft 0 In
0 ft 0 in
None
None
11
s
5
Metal
Double (Clear)
Yes
0.62
0.26
N
43.3 112
0 ft 0 in
0 ft 0 in
None
None
- 12
s
5
Metal
Double (Clear)
Yes
0.62
0.26
N
112.4 ft2
0 ft 0 in
0 ft 0 In
None
None
13
s
5
Metal
Double (Clear)
Yes
0.62
0.26
N
31.6 ft
0 ft 0 in
0 ft 0 in
None
None
_ 14
s
5
Metal
Double (Clear)
Yes
0.62
0.26
N
6.5 112
0 ft 0 in
0 ft 0 in
None
None
_ 15
w
6
Metal
Double (Clear)
Yes
0.62
0.26
N
21.3 ft2
0 ft 0 In
0 ft 0 In
None
None
_ 16
w
6
Metal
Double (Clear)
Yes
0.62
0.26
N
43.3 ft2
0 ft 0 in
0 ft 0 in
None
None
17
W
6
Metal
Double (Clear)
Yes
0.62
0.26
N
9.0 112
0 ft 0 in
0 ft 0 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
582 112
582 112
64 ft
9.3 ft
1
i.
1/17/2019 10:43 AM
k�.
EnergyGauge® USA Section R405.4.1 Compliant Software
Page 3 of 5
'FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000295
1851.5 101.64 191.16 .2301 5
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Strip Heat/
None
COP:1 29A8 kBtulhr
1
sys#1
COOLING SYSTEM
•;V # System Type
Subtype
Efficiency Capacity Air Flow SHR
Block
Ducts
1 Central Unit/
Split
SEER: 16 48 kBtu/hr 1440 cfm 0.7
1
sys#1
HOT WATER SYSTEM
# System Type SubTpe
Location
EF Cap Use SetPnt Conservation
1 Electric None
Main
0.94 50 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft.
DUCTS
Supply—
V # Location R-Value Area
—Return— Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT ON
RLF
HVAC#
Heat Cool'
1 Attic 6 697 fN
Attic
511 ft- Default Leakage Main (Default) (Default)
1 1
TEMPERATURES
rogramable Thermostat: Y
Fe
coiling an Mar
enting Jan Feb Mar
r
Ceiling Fans: ay nrIX]
r JU Jul Au Sep Oct
lhJ Apr [ May Jun [ ] Jul Aug Sep
Oct
Nov
Nov
Dec
Dec
r-
1117/2019 10:43 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
-Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WO)
AM
78
78
78
78
78
78
78
78
80
80
80
80
_
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
_ PM
78_
78
78.
78.
78
78
78
78
78
78
78
-78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
fib
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture
Fraction
Space
' Default 8 Ibs/s
.ft.
0 ft'
0 It
0.3
Main
Name: Signature:
Rating Compant: Date:
1/17/2019 10:43 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
48.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
2389
d) Room uniVPTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.620
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.260
14. Heating system: Capacity
29.5
c) Area
7c.
450.3
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier Installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.0
15. Water heating system
a) Electric resistance EF 0.94
b) Gas fired, natural gas EF
c) Gas Fred, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
0 Heat recovery unit HeatRec%
g) Other ,
10131. 11.0
10132.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a. 30.0
b) Cross ventilation No
11b.
c) Whole house fan No
11c,
d) Multizone cooling credit
11d. No
e) Multizone heating credit
0 Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be ittalled (or exceeded) In this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Address of New Home: 9623 KNOLLWOOD LN City/FL Zip: FORT PIERCE, FL 34951
1/17/2019 10:44:04 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
wrightsoft' Load Short Form
Entire House
Project Information
For: MW-05
9623 KNOLLWOOD LN, FORT PIERCE, FL 34951
Job:
Date: Dec 13, 2018
By:
Design Information
Htg CIg Infiltration
Outside db (OF) 43 90 Method Simplified
Ins ide db (° F) 70 72 Construction quality Tight
Design TO (°F) 27 18 Fireplaces 0
Daily range - L
>^ Inside humidity (°/a) 30 50
Moisture difference (gr/lb) 0 68
HEATING EQUIPMENT
COOLING EQUIPMENT
Make
Make Carrier
Trade
Trade 16 SEER PURON AC
Model
Cond CA16NA048""A
AHRI ref
Coil FV4CNB006
AHRI ref 4585139
Efficiency
100 EFF
Efficiency 14.0 EER,
16 SEER
Heating input
8.6
kW
Sensible cooling
32550
Btuh
Heating output
29480
Btuh
Latent cooling
13950
Btuh
Temperature rise
17
OF
Total cooling
46500
Stuh
„ Actual air flow
1550
cfm
Actual air flow
1550
cfm
Air flow factor
0.047
cfm/Btuh
Air flow factor
0.046
cfm/Btuh
Static pressure
0
in H2O
Static pressure
0
in H2O
Space thermostat
Load sensible heat ratio
0.72
ROOM NAME
Area
(ft2)
Htg load
(Btuh)
Clg load
(Btuh)
Htg AVF
(cfm)
Clg AVF
(cfm)
MASTER SUITE
405
5903
5432
280
248
HER WIC
86
1235
752
59
34
HIS WIC
44
47
242
2
11
GREAT ROOM
441
5191
5244
246
240
DINING
159
3028
2910
143
133
FOYER
57
1269
1017
60
47
NOOK
142
2575
2217
122
101
KIT
164
172
1673
8
77
BED 2
184
1888
3060
89
140
BED3WIC
33
1061
634
50
29
CABANA
76
2110
1820
100
83
BED 3
243
2217
3245
105
148
BATH 2
59
1033
1177
49
54
UTILITY
4s_
52—
672—
2
31
MECH
34
414
613
20
28
MARTFR RATH
211
4512
3192 214 146
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2018-Deo-14 12:36:36
�� wrightsoit� RlghtSulte® Universal 201212.1.06 RSU02818 Page 1
R�+Cii1 C:1UsersUason\Documents\Wrlghmoft HVACWW-05.mp Gale =MIA Front Door faces: N
Entire House
2386
32707
33900
1550
1550
Other equip loads
0
0
Equip. @ 0.95 RSM
32205
Latent cooling
12935
TOTAI S
qo7n7 I
I.J. IJJV
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wri htsoft 2018-Deo-16 12:36:36
9 RlghtSuRe® Universal 201212.1.05 RSU02818 Page
�+� C:\UsemUason\Documents%Wrlghtsofl HVACWVV-05.rup Cato =MJ8 Front Door feces: N
wrightsoft•
Project Summary
Entire House
Project Information
For: MW-05
9623 KNOLLWOOD LN, FORT PIERCE, FL 34951
Notes:
Design Information
Weather:
Winter Design Conditions
Outside db
43
OF
Inside db
70
OF
Design TO
27
OF
Heating Summary
Structure
26948
Btuh
Ducts
5759
Btuh
Central vent (0 cfm)
0
Btuh
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
32707
Btuh
Infiltration
Method
Construction quality
Fireplaces
Vero Beach, FL, US
Simplified
Tight
0
Heating
Cooling
Area (ft')
2386
2386
Volume (fF)
24178
24178
Air changes/hour
0.11
0.06
Equiv. AVF (cfm)
44
24
Heating Equipment Summary
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Job:
Date: Dec 13, 2018
By:
Summer Design Conditions
Outside db
90
OF
Inside db
72
OF
Design TO
18
OF
Daily range
L
Relative humidity
50
%
Moisture difference
68
gr/lb
Sensible Cooling Equipment Load Sizing
Structure
26782
Btuh
Ducts
7118
Btuh
Central vent (0 cfm)
0
Btuh
Blower
0
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Equipment sensible load
32205
Btuh
Latent Cooling Equipment Load Sizing
Structure
10615
Btuh
Ducts
2320
Btuh
Central vent (0 cfm)
0
Btuh
Equipment latent load
12935
Btuh
Equipment total load
45140
Btuh
Req. total capacity at 0.70 SHR
3.8
ton
Cooling Equipment
Summary
Make Carrier
Trade 16 SEER PURON AC
Cord CA16NA048""A
Coil FV4CNB006
AHRI ref 4585139
100 EFF
Efficiency
8.6
kW
Sensible cooling
29480
Btuh
Latent cooling
17
OF
Total cooling
1550
cfm
Actual air flow
0.047
cfm/Btuh
Air flow factor
14.0 EER, 16 SEER
32550
Btuh
13950
Btuh
46500
Btuh
1550
cfm
sensible heat ratio 0.72
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft RightSUMQD UnWersaIM212.1.05 RSU02818 2018-Dec-1412:36:36
Page 1
14ECk HVAC\MW-05.rup CeIc=MJB Front Door (aces:N
GHO HOMES
MW-05
9623 KNOLLWOODLANE
FORT PIERCE, FL 34951