Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODERECEIVED FORM R405-2017 FEB 15 2019 FLORIDA ENERGY EFFICIENCY CODE FOR SURc."DWO I@QNS TRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 96 Builder Name: GHO HO Street: 9623 KNOLLWOOD LN Permit Office: ST LUCI I ILGDCNTC®PY City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: Owner: Jurisdiction: _ Design Location: FL, ST_LUCIE_CO_INTL County: st. lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(2422.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.0 2127.10 ft2 b. -Wood, Adjacent R=11.0 295.61 ft2 3.1 Number of units, if multiple family 1 c. N/Ame R= ft2 4.;Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2389.0 sqft.) Insulation' Area a. Under Attic (Vented) R=30.0 2389.00 ft= 6. Conditioned floor area above grade (ft2) 2389 b. N/A R= ft' Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft' 7. Windows(450.3 sqft.) Description Area a. Sup: Attic, Rat: Attic, AH: Main 6 697 a. U-Factor: Dbl, U=0.62 450.28 ft2 SHGC: SHGC=0.26 b.'U-Factor: N/A ft2 12. Cooling systems kBtu(hr Efficiency SHGC: a. Central Unit 48.0 SEER:16.00 - c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency .d. U-Factor: NIA ft2 �7 a. Electric Strip Heat 29.5 COP:1.00 r}},� SHGC: wt aaWeighted Average Overhang Depth: ' 0.000 ft. .9rea Weighted Average SHGC: 0.260 14. Hot waters stems Y 8.-Floor Types (2389.0 sgft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 2389.00 ft2 b. Conservation features EF: 0.940 ti. N/A R= ft2 None c. N/A R= ft2 15. Credits Pslat Glass/Floor Area: 0,188 Total Proposed Modified Loads: 77.98 PASS Total Baseline Loads: 78.03 'I hereby certify that the plans and specifications covered by Review of the plans and ST,gr� this calculation a in Iiance with the Florida Energy specifications covered by this OF•Slie ti , , _ s , O Code. calculation indicates compliance with the Florida Energy Code. �. nrn.'••%.:aii.+;:.'�,� O PREPARED B : Before construction is completed ` DATE: -I this building will be inspected for compliance with Section 553.908 t „ I hereby certify that i g, as design is in compliance Florida Statutes. with the Florid ner od C01) -OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. •- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with_R402.4.1..1_and_this_ ro'ect.requires_an no greater than 5.00 ACH50 (R402.4.1.2). E SCANNED BY St. Lucie County 1/17/2019 10:43 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 5 190�-03/� FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: _ Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: MW-05 Bedrooms: 3 User Conditioned Area: 2389 Total Stories: 1 _ 1 _ _Worst. Case:. No. GHO HOMES Rotate Angle: 0 ST LUCIE BUILDING DPTMN Cross Ventilation: No Whole House Fan: No Single-family New (From Plans) Address Type: Lot# Block/Subdivision: PlatBook:. - - - Street: County: City, State, Zip: Street Address - 9623 KNOLLWOOD LN St. lucie FORT PIERCE, FL, 34951 CLIMATE _ / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range T FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 2389 22217.7 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfI ID Finished Cooled Heated " 1 Main 2389 22217.7 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 215.9 It 0 2389 ft' 0 0 1 ROOF V # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Tested Emilt Deck Pilch Tested Insul. (deg) 1 Hip Concrete 2672 It' 0 ft' Medium 0.4 N 0.9 No 0 26.6 ATTIC / ' V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2389 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) Main 30 Blown 2389 f1' 0.1 Wood -1/1712019 10:43 AM 3= c EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5 FORM WALLS Adjacent S Pace Cavity Width Height Sheathing Framing Solar Below -lJillt Tn WaILTypa R-value Fr in Ft rn Area R_value-F1aC8on_._AbSorrGrada%_ _ 1 N Exterior Concrete Block- EM Insul Main 4 32 0 11 4 362.7 ft' 0 0 0.3 0 -2 NE, -Exterior Concrete Block -.Ext.lnsul-Main 4 2 11-1.1_ 4 33.1 M 0 0 0.3 0- 3 E Exterior Concrete Block- Ext Insul Main 4 55 11 9 4 521.9 ft' 0 0 0.3 0 4 BE Exterior Concrete Block - EM Insul Main 4 8 7 11 4 97.3 ft- 0 0 0.3 0 _ 5 ,--5 S Exterior Concrete Block - EM Insul Main 4 58 2 9 4 542.9 ft- 0 0 0.3 0 -6 W Exterior Concrete Block - Exl Insul Main 4 61 0 9 4 569.3 ft' 0 0 0.3 0 7 - Garage Frame - Wood Main 11 26 1 11 4 295.6 ft2 0 0.25 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Wood Main None .39 3 8 24 ft' WINDOWS -_ ./ Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Inl Shade Screening _ 1 n 1 Metal Double (Clear) Yes 0.62 0.26 N 48.0 ft- 0 ft 0 in 0 ft 0 in None None 2 n 1 Metal Double (Clear) Yes 0.62 0.26 N 8.0 112 0 ft 0 in 0 ft 0 in None None 3 n 1 Metal Double (Clear) Yes 0.62 0.26 N 8.0 ft2 0 ft 0 in 0 ft 0 in None None 4 n 1 Metal Double (Clear) Yes 0.62 0.26 N 21.7 ft2 0 ft 0 in 0 ft 0 in None None 5 ne 2 Metal Double (Clear) Yes 0.62 0.26 N 16.0 ft2 0 ft 0In 0 ft 0 In None None 6 e 3 Metal Double (Clear) Yes 0.62 0.26 N 21.3 ft2 0 ft 0 In 0 ft 0 in None None 7 e 3 Metal Double (Clear) Yes 0.62 0.26 N 6.5 112 0 ft 0 In 0 ft 0 in None None _ 8 e 3 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft2 0 ft 0 in 0 ft 0 in None None 9 se 4 Metal Double (Clear) Yes 0.62 0.26 N 20.0 ft' 0 ft 0 In 0 ft 0 in None None' 10 se 4 Metal Double (Clear) Yes 0.62 0.26 N 21.3 112 0 ft 0 In 0 ft 0 in None None 11 s 5 Metal Double (Clear) Yes 0.62 0.26 N 43.3 112 0 ft 0 in 0 ft 0 in None None - 12 s 5 Metal Double (Clear) Yes 0.62 0.26 N 112.4 ft2 0 ft 0 in 0 ft 0 In None None 13 s 5 Metal Double (Clear) Yes 0.62 0.26 N 31.6 ft 0 ft 0 in 0 ft 0 in None None _ 14 s 5 Metal Double (Clear) Yes 0.62 0.26 N 6.5 112 0 ft 0 in 0 ft 0 in None None _ 15 w 6 Metal Double (Clear) Yes 0.62 0.26 N 21.3 ft2 0 ft 0 In 0 ft 0 In None None _ 16 w 6 Metal Double (Clear) Yes 0.62 0.26 N 43.3 ft2 0 ft 0 in 0 ft 0 in None None 17 W 6 Metal Double (Clear) Yes 0.62 0.26 N 9.0 112 0 ft 0 in 0 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 582 112 582 112 64 ft 9.3 ft 1 i. 1/17/2019 10:43 AM k�. EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5 'FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000295 1851.5 101.64 191.16 .2301 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 29A8 kBtulhr 1 sys#1 COOLING SYSTEM •;V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 48 kBtu/hr 1440 cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Main 0.94 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft. DUCTS Supply— V # Location R-Value Area —Return— Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC# Heat Cool' 1 Attic 6 697 fN Attic 511 ft- Default Leakage Main (Default) (Default) 1 1 TEMPERATURES rogramable Thermostat: Y Fe coiling an Mar enting Jan Feb Mar r Ceiling Fans: ay nrIX] r JU Jul Au Sep Oct lhJ Apr [ May Jun [ ] Jul Aug Sep Oct Nov Nov Dec Dec r- 1117/2019 10:43 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT -Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WO) AM 78 78 78 78 78 78 78 78 80 80 80 80 _ PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 _ PM 78_ 78 78. 78. 78 78 78 78 78 78 78 -78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 fib 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space ' Default 8 Ibs/s .ft. 0 ft' 0 It 0.3 Main Name: Signature: Rating Compant: Date: 1/17/2019 10:43 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 48.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2389 d) Room uniVPTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.620 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260 14. Heating system: Capacity 29.5 c) Area 7c. 450.3 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier Installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.0 15. Water heating system a) Electric resistance EF 0.94 b) Gas fired, natural gas EF c) Gas Fred, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ 0 Heat recovery unit HeatRec% g) Other , 10131. 11.0 10132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11c, d) Multizone cooling credit 11d. No e) Multizone heating credit 0 Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be ittalled (or exceeded) In this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Address of New Home: 9623 KNOLLWOOD LN City/FL Zip: FORT PIERCE, FL 34951 1/17/2019 10:44:04 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 wrightsoft' Load Short Form Entire House Project Information For: MW-05 9623 KNOLLWOOD LN, FORT PIERCE, FL 34951 Job: Date: Dec 13, 2018 By: Design Information Htg CIg Infiltration Outside db (OF) 43 90 Method Simplified Ins ide db (° F) 70 72 Construction quality Tight Design TO (°F) 27 18 Fireplaces 0 Daily range - L >^ Inside humidity (°/a) 30 50 Moisture difference (gr/lb) 0 68 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Carrier Trade Trade 16 SEER PURON AC Model Cond CA16NA048""A AHRI ref Coil FV4CNB006 AHRI ref 4585139 Efficiency 100 EFF Efficiency 14.0 EER, 16 SEER Heating input 8.6 kW Sensible cooling 32550 Btuh Heating output 29480 Btuh Latent cooling 13950 Btuh Temperature rise 17 OF Total cooling 46500 Stuh „ Actual air flow 1550 cfm Actual air flow 1550 cfm Air flow factor 0.047 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.72 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) MASTER SUITE 405 5903 5432 280 248 HER WIC 86 1235 752 59 34 HIS WIC 44 47 242 2 11 GREAT ROOM 441 5191 5244 246 240 DINING 159 3028 2910 143 133 FOYER 57 1269 1017 60 47 NOOK 142 2575 2217 122 101 KIT 164 172 1673 8 77 BED 2 184 1888 3060 89 140 BED3WIC 33 1061 634 50 29 CABANA 76 2110 1820 100 83 BED 3 243 2217 3245 105 148 BATH 2 59 1033 1177 49 54 UTILITY 4s_ 52— 672— 2 31 MECH 34 414 613 20 28 MARTFR RATH 211 4512 3192 214 146 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Deo-14 12:36:36 �� wrightsoit� RlghtSulte® Universal 201212.1.06 RSU02818 Page 1 R�+Cii1 C:1UsersUason\Documents\Wrlghmoft HVACWW-05.mp Gale =MIA Front Door faces: N Entire House 2386 32707 33900 1550 1550 Other equip loads 0 0 Equip. @ 0.95 RSM 32205 Latent cooling 12935 TOTAI S qo7n7 I I.J. IJJV Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft 2018-Deo-16 12:36:36 9 RlghtSuRe® Universal 201212.1.05 RSU02818 Page �+� C:\UsemUason\Documents%Wrlghtsofl HVACWVV-05.rup Cato =MJ8 Front Door feces: N wrightsoft• Project Summary Entire House Project Information For: MW-05 9623 KNOLLWOOD LN, FORT PIERCE, FL 34951 Notes: Design Information Weather: Winter Design Conditions Outside db 43 OF Inside db 70 OF Design TO 27 OF Heating Summary Structure 26948 Btuh Ducts 5759 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 32707 Btuh Infiltration Method Construction quality Fireplaces Vero Beach, FL, US Simplified Tight 0 Heating Cooling Area (ft') 2386 2386 Volume (fF) 24178 24178 Air changes/hour 0.11 0.06 Equiv. AVF (cfm) 44 24 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Job: Date: Dec 13, 2018 By: Summer Design Conditions Outside db 90 OF Inside db 72 OF Design TO 18 OF Daily range L Relative humidity 50 % Moisture difference 68 gr/lb Sensible Cooling Equipment Load Sizing Structure 26782 Btuh Ducts 7118 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 32205 Btuh Latent Cooling Equipment Load Sizing Structure 10615 Btuh Ducts 2320 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 12935 Btuh Equipment total load 45140 Btuh Req. total capacity at 0.70 SHR 3.8 ton Cooling Equipment Summary Make Carrier Trade 16 SEER PURON AC Cord CA16NA048""A Coil FV4CNB006 AHRI ref 4585139 100 EFF Efficiency 8.6 kW Sensible cooling 29480 Btuh Latent cooling 17 OF Total cooling 1550 cfm Actual air flow 0.047 cfm/Btuh Air flow factor 14.0 EER, 16 SEER 32550 Btuh 13950 Btuh 46500 Btuh 1550 cfm sensible heat ratio 0.72 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft RightSUMQD UnWersaIM212.1.05 RSU02818 2018-Dec-1412:36:36 Page 1 14ECk HVAC\MW-05.rup CeIc=MJB Front Door (aces:N GHO HOMES MW-05 9623 KNOLLWOODLANE FORT PIERCE, FL 34951