Loading...
HomeMy WebLinkAboutEVALUATION REPORTS. ` TRINITY !ERD EVALUATION REPORT r.NTCGRA R O O F T I L E Entegra Roof Tile, LLC 1289 NE 9th Avenue Okeechobee, FL34972 (602)515-6933 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the construction materials in the State of Florida. The documental P.E. for use of the product under the Florida Building Code products described herein have been evaluated for complial (HVHZ) sections noted herein. DESCRIPTION: Entegra Concrete Roof Tiles (HVHZ LABELING: Labeling shall be in accordance with the herein. EXTERIOR RESEARCH & DESIGN, U.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 (203)262-9245 Evaluation Report E39310.11.11-1-R4 FL7804-R30 Date of Issuance:12/02/2011 Revision 4: 10/17/2017 Dlicable rules and regulations governing the use of submitted has been reviewed by Robert Nieminen, d Florida Building Code, Residential Volume. The with the 6 h Edition (2017) Florida Building Code SCANNED BY St. Lucie County is the Accredited Quality Assurance Agency noted CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or proYisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityIERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity(ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report isdisplayed , then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The far bofle seal appndng was aalloriaed by Robert Nie nWen, P.L on 10117/2017. This does noturye as an eleaaNady signed damment. Signed, sealed hardmpies have been taiamitled to the Pmdua Approval Adminutrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity] ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being Issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity] ERD nor Robert 4ieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereo , is/was used for permitting or design guidance unless retained -- specifically -for- that purpose. ---- ---- — TRINITY iERD ROOFING SYSTEM EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roofing Tiles Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated compliance with the following sections of the Fl Irida Building Code through testing in accordance with the following Standards. Compliance is subject to the installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section 1523.6.5.2 1523.6.5.2 1523.6.5.2.2 1523.6.5.2.3 1523.6.5.2.3 3. REFERENCES: Enti ERD(TST6049) ATL(TST3782) ATL (TST3782) ATL(TST3782) ATL (TST3782) ATL (TST 3782) ATL (TST 3782) ATL (TST 3782) ATL (TST 3782) ATL (TST 3782) Miami -Dade (CER1592) Miami -Dade (CER1592) Miami -Dade (CER1592) Miami -Dade (CER1592) Miami -Dade (CER1592) Tile Roof Institute PRI (QUA9110) Exterior Research and Design, U.C. CeB/lrote ofAuthanrution 09503 Property Standard Year Physical Properties TAS 112 1995 Wind Driven Rain TAS 100 1995 Static Uplift Resistance TAS 101 1995 Static Uplift Resistance TAS 102 1995 Static Uplift Resistance TAS 102(A) 1995 Examination Reference Date TAS 101 P39740.02.12 02/21/2012 Physical Properties RT0624.05-14 07/03/2014 Physical Properties RT0624.04-14 07/07/2014 Physical Properties RT1210.02-15 12/17/2015 Physical Properties RT1210.03-15 12/17/2015 Physical Properties RT1103.01-15 11/07/2015 Physical Properties RT1103.02-15 11/07/2015 Physical Properties RT1103.03-15 11/07/2015 Physical Properties RT1103.04-15 11/07/2015 Physical Properties RT1103.05-15 11/07/2015 HVHZ Compliance 14-0416.12 11/27/2014 HVHZ Compliance 15-0721.04 11/05/2015 HVHZ Compliance 16-0112.06 02/25/2016 HVHZ Compliance 16-0112.07 02/25/2016 HVHZ Compliance 16-0112.08 02/25/2016 TAS 100, TAS 101, 102, 302(A) Membership Confirmation Current Quality Assurance Service Confirmation Exp.11/02/2018 Evaluation Report E39310.11.11-1-R4 6'EDITION (2017) FBC HVHZ EVALUATION FL7804-R30 Entegra Roof Tiles Revision 4: 10/17/2017 Page 2 of 8 a. TRINITY' ERD 17A5 1A 7. Tvna 3a (flat-nrnfilel� ��—� I I BERMUDA FAT. PLANTATION FLIT anL[.HORIZON FLAT Is, Be Horizon Flat Exterior Research and Design, Ur I Evaluation Report E39310.11.11-1-R4 Certifitote o7Autho. .don 09503 6.EDITION (2017) FDC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles, Revision 4:10/17/2017 Page 3 of 8 TRINITY ERD 4.2 TAS 112, Type la (interlocking;Ihigh-profile) BELLA HIGH, "S" 1 13-4" Bella High "S" 4.3 TAS112, Type lb (interlocking, low-pro£Ie) . ESTATE"S" and HACIENDA Nail Holes T ra 16. i Estate "S" � Hacienda 4-3TA5112, Type 2a (non -interlocking, highL,profile) GALENASPANISH"S" and REGAL f a \_ 17" a Ur10" Y Galena Spanish "S" Regal Exterior Research and Design, I.I.C. IEvaluation Report E39310.11.11-1-114 Dernfimte oJAuthori+ation 49503 da' EOITION 12017J FOC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 4 of 8 I TRINI IY i ERD S. LIMITATIONS: -5.1 - This is a building code evaluation: --Neither Trini y)ERD-nor Robert Nieminen, P.E. are,, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or others adopting FBC HVHZ requirements. 5.3 Fire classification is not part of this evaluation; refer to FBC 1516 or listing by an approved testing agency for fire rating of this product. 5.4 Reference is made to FBC 1512.4.2.4 regarding field testing of completed tile roof installations. 5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in accordance with TAS 112, AppendixA, 5.6 Minimum underlayment shall comply with the RAJ 118, RAS 119 or RAS 120, as applicable. Underlayment products shall hold current Florida Statewide Product Approval or Local Approval for use in the roof assemblies in FBC HVHZ jurisdictions. i 5.7 Minimum roof deck requirements shall be in accordance with. applicable FBC HVHZ requirements.: 5.8 All products in the roof assembly shall have quality assurance audit in accordance with the F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Entegra Concrete Roof Tiles may be mechanically1 fastened, mortar -set or adhesive -set. Installation shall comply with manufacturers current published (nst�'uctions, but not less than the requirements of RAS 118, RAS 119 or RAS 120, as applicable. 6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment -Based System' in accordance with Roofing Application Standard RASI127-11 using the data outlined herein. , - - .TABLE_ 1: AERODYNAMIC MULTIPUERS-7,(w) , Tile Batten Application Direct -Deck Application Bermuda Flat 0.189 0.205 Plantation Flat 0.267 0.289 Horizon Flat 0.305 0.330 Bella High "S" 0.349 0.378 Estate "S" 0.267 ( 0.289 Hacienda 0.267 0.289 Galena Spanish "S" N/A 0.235 Regal 0.287 0.311 ' TABLE 2:RESTORING. MOMENT DUE !no GRAVITY-M,(FT-LBF) Roof Slope (0) Tile 2:12<0<3:12 3:12<0<4:12 4:12<0<5::12 5:12<0<6:12 6:12<0<7:12 0>7:12 Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Bermuda Flat 5.22 6.43 5.17 6.37 5.09 6127 4.98 6.15 4.86 6.00 4.72 5.83 Plantation Flat 7.22 7.91 6.85 7.79 6.75 7167 6.61 7.52 6.44 7.32 6.25 7.04 Horizon 7.60 8.32 7.52 8.24 7.41 8112 7.26 7.95 7.09 7.76 6.89 7.55 Bella High "5" 6.19 6.89 6.11 6.80 5.99 6167 5.85 6.51 5.68 6.33 5.50 6.13 Estate "S" 6.14 6.84 5.91 6.74 5.82 6164 5.70 6.50 5.56 6.33 5.40 6.14 Hacienda 5.92 6.80 5.92 6.80 5.82 6;69 1 5.70 6.55 5.56 6.39 5.41 6.22 Galena Spanish"S" N/A 6.20 N/A 6.13 N/A 603 N/A 5.89 N/A 5.74 N/A 5.57 Regal 7.77 8.34 7.77 8.34 7.65 8..20 7.49 8.03 73 0 7.83 7.10 7.61 Exterior Research and Design, U.C. I Ceniiimte o)Authonratlon A9503 OEDmON(2017) FBC HVHZ EVALUATION Entegra Roof Tiles Evaluation Report E39310.11.11-1-R4 FL7804-R10 Revision 4: 10/17/2017 Page 5 of 8 r� 1 TRINITY ERD TABLE 3A: ATTACHMENT RESI"CE -MECHANIC4LLYATTACHED EXPRESSED AS,A MOMENT -MF(FT-LBF) , SYSTEMS- - Tile Fastener Direct -Deck (min. 15/32" ,plywood) Direct -Deck (min. 19/32" plywaodl Battens Type If Size r Shank Gip Nail One (1) 10d Smooth or Screw N/A 7.3 9.8 4.9 Nail Two (2) 10d Smooth or Screw N/A 14.0 18.8 7.4 Nail One (1) 30d Smooth or Screw Eave 19.0 19.0 22.1 Nail One (1) 10d Smooth cr5crew Field 24.3 24.3 24.2 Nail Two (2) iod I Smooth or5crew Eave 31.9 31.5 34.8 Flat, Iantad Flator Nail Two (2) 10d Smooth or Screw Field 35,5 35.5 34.8 Ho n Nail Two (2) 10d Ring N/A 30.9 38.1 17.2 Nails Two(2)1 Sods I Ringr N/A 50.3' 65.5' 48.3' Screw One (1) #8 N/A N/A 30.8 30.8 18.2 crew Two (2) NS N/A N/A 51.7 51.7 24.4 'Installation with a 4-inch tile headlap and fasteners located min. 2%-Inch from head of tile. Nail One (1)' 10d Smooth orSaew N/A 8.8' 11.8' 4.1' Nail Two (2) 10d Smooth or Screw N/A 16.4 21.9 7.1 Nail One (1)' SOd Smooth or Screw Eave 19.0' 19.0' 22.1' Nail One (1)' 30d Smooth or5crew Field 24.3' 24.3' 24.2s Nail Two (2) 10d Smooth or Screw Eave 31.9 31.9 32.2 Nail Two (2) iod I Smooth or5crew Field 35.5 35.5 34.8 Estate "S" or Hacienda Nail Two (2) lOd Ring N/A 27.8 37.4 28.8 Nail' Two 10d' I Ring' N/A 43.0' 67.5' 50.91 Screw One(1)2 #8 I N/A N/A 25.81 25.8' 22.92 Screw Two (2) #8 N/A NIA 47.1 47.1 49.1 ' Installation with a 4-Inch tile headlap andlifasteners looted min. 2%-inch from head of tile. 'For one (2) fastener installations, utilize hole that is approximately 4Y-inch from the Interlocking edge. Nail One (1) 10d I Smooth or Screw N/A 5.1 6.8 2.8 Nail Two (2) 10d Smooth or Screw N/A 6.9 9.2 7.3 Nail One(1) 30d I Smooth or Screw Field 23.1 23.1 19.0 Nail One (1) 10d I Smoothor5crew Eave 29.3 29.3 24.0 Nail Two (2) 10d Smooth or Screw Field 27.6 27.6 38.6 Bella High "S", Galena Nail Two (2) 10d Smooth or Screw Eave 38.1 38.1 41.8 Spanish "S" or Regal Nall Two (2) SOd Ring .2 19.4 Nail, Two (2)' 10d' Ring' WNIA20.7 11 509' Screw One (1) NB l N/A .7 18.1 Screw Two (2) #8 N/A .2 29.8 1Installation with a 4-inch rile headlap and fasteners located min. 2%-inch from head of tile. Exterior Research and Design, U.C. Evaluation Report E39310,11,11-1-114 certf/hate of Authorization#9503 61M EDITION(2017) FBC HVNZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4: 10/17/2017 Page 6 of 8 ,I 'T'RINIIY ERD - - ----- TABLE 4:-ATTACHMENT-RESISTANCEE%PRE4ED AS A' MOMENT -MF(FT-LBF) - -- ----- - MORTAR AND ADHESIVE -SET SYSTEMS - - Note from Entegra Roof Tile, LLC.: The performance data listed in Tattle 4.are based on therespective' adhesive -manufacturers' test reports and Miami -Dade NOAS. Entegra Roof rile, LLC relies upon the adhesive manufacturers to provide these values for our inclusion in this FBC. HVHZ Evaluation Report.. Please consult the individual adhesive manufacturer for informotion on product approvals, limitations, revisions or other information for determining wind load and overturning momentperformance. Tile Adhesive Tile Product ProductlApproval Placement Mf (ft-lbf) "TILE BOND'"" by Dow Chemical NOA 1G-0222.01 Interdependent (2-paddy) 41 Bermuda 'Touch N' Seal Storm Bond" by DAP Foam NOA ld',-0421.03 Interdependent (2-paddy) 73 Flat, "polyset° RTA-1" by ICP Adhesives &Sealants NOA 16-0315.03 ' Interdependent (2-paddy) 52 Plantation Flat n Horizon "Polyset®AH-160" by ICP Adhesives & Sealants NOA 17I-0322.03 Interdependent (2-paddy) 43 Independent (medium paddy, -30 g) 51 Independent (large paddy,-45 g) 92 'TILE BOND"'" by Dow Chemical NOA ifi-0222.01 Interdependent (2-paddy) 44 'Touch N' Seal Storm Bond" by DAP Foam NOA 1d-0421.03 Interdependent (2-paddy) 42 "5" "Polyset® RTA-1" by ICP Adhesives & Sealants NOA 16-0315.03 Interdependent (2-paddy) 44 Estate or Hacienda "Polyset° AH-160" by ICP Adhesives & Sealants NOA 1 i 0322.03 Interdependent (2-paddy) 50 Independent (medium paddy, -30 g) 37 Independent (large paddy,-54 g) 61 Mortar Various Per RAS 120 21 'TILE BOND'"" by Dow Chemical NOA 1fi-0222.01 Interdependent (2-paddy) 48 'Touch N' Seal Storm Bond" by DAP Foam NOA 1G-0421.03 Interdependent (2-paddy) 52 Bella High "S", "Polyset® RTA-1" by ICP Adhesives & Sealants NOA 16-0315.03 Interdependent (2-paddy) 36 Galena Spanish "5" or Regal "Polyset® AH-160" by ICP Adhesives & Sealants NOA 1i-0322.03 Interdependent (2-paddy) 30 Independent (medium paddy,-30 g) 49 Independent (large paddy, `63 g) 94 Mortar Various Per RA5120 25 7. LABELING: 7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. land/or ERR u "5'_", Galena SRanish_'S" Exterior Research and Design, LLC. i Evaluation Report E39310.11.11-1-R4 CenifimteofAuthodroaon 09503 6'"EDITION(2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof riles Revision 4: 10/17/2017 s Page 7 of 8 TRINITY ERD Hanson Labeli g: Horizon Flat, Hacienda, Regal 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority aving Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Plant Profilei* , Okeechobee, FL Bermuda Flat, Plantation Flat, Estate "5", Bella High "5", Galena Spanish "S" Ft. Myers, FL Horizon Flat, Hacienda Deerfield Beach, FL Horizon Flat, Hacienda, Regal 10. QUALITY ASSURANCE ENTITY: PRI Construction Materials Technologies, LLC. — i UA9310; (813) 621-5777 - END OF EVALUATION REPORT — Exterior Research and Design, U.C.Evaluation Report E39310.11.11-1-R4 rertl(7rnte o)Authorlmtion a9503 Gr" EDITION(2017) FBC HVHZ EVALUATION FL7804-ft10 Entegra Roof Tiles Revision 4:10/17/2017 Page 8 of 8 RECEIVED FFg 21 1018 permitting Department NEORECta. St. Lucie County Certificate of Authorization N32455 to 353-Christian-Street,.Unit #13- Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY Boral Roofing 7575 , CA. Center Drive, Suite 100 FILE C 0 PY Irvine, A92618 (602)269-2288 on Report M35710.12.30-Ril FL14317-R10 Date of issuance:12/21/2010 Revision 11:10/12/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The described herein have been evaluated for compliance with the 6w Edition (2017) Florida Building Co I IV S-noted herein. BY DESCRIPTION: Boral Roof Underlayments St. Lucie County LABELING: labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO ietc. Evaluated" may be displayed in advertising literature. if any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPErnON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building official. This Evaluation Report consists of pages 1 through 8. Prepared by: n„.y,,,,-." ; *� i ��'• • ;-,, ., "%�"'• Thefaalmile seal appearing was authorized by Robert Robert J.M. Nieminen, P.E. i-..'•�, Wemnen,P.Eon10/12/20MThis doesnot semeasan Florida Registration No. 59166, Florida OCAANE7983 ,,.. ;, .....•. eectron;miry signeddocument CERTFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the —product 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record orany project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. NNEMOletc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Boral Roof Underlayments, as marketed by Boral Roofing, have demonstrated compliance with the following sections of the 6t6 Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Property manuaru — 2012 1504.3.1 1507.1.1, T1507.1.1, Wind Uplift Physical Properties UL 1897 ASTM D1970 2015 1507.2.9.2 1507.3.3 Physical Properties FRSA/TRI April 2012 (04-12) 2012 Enti Examination Reference Date o9/30/2011 ERD (TST 6049) Physical Properties M36790.07.11 08/28/2012 ERD (TST 6049) Physical Properties Tensile Adhesion / LTA B40380.08.12 C41420.09.12-2 09/11/2012 ERD (TST 6049) ERD (TST 6049) Adhesion 841940.09.12 09/13/2012 2014 09//04/201 ERD (TST 6049) Tensile Adhesion / LTA B4739D.07.14-1 ERD (TST 6049) Tensile Adhesion / LTA 347390.09.14 11/2/2017 OC (PDM1838) Physical Properties Equivalency statement 027/2010 12/03 PRI (TST 5878) ASTM D1970 NEI-031-02-02:REV NEI-029-02-01:REV 1 //2010 PRI (TST 5878) PRI (TST 5878) ASTM D1970 Tensile Adhesion / LTA NEI-046-02-01REV 12/17/2010 PRI (TST5878) FRSA/TRI April 2012 NEI-076-02-01 02/14/2011 01/29/2013 PRI (TST 5878) ASTM D1970 Wind Uplift NEI-034-02-02 BORR-001-02-01 03/17/2015 PRI (TST 5878) PRI (TST 5878) Wind Uplift BORR-005-02-01 06/24/2015 PRI (TST 5878) Tensile Adhesion / LTA DAPF-002-02-01 03/08/2018 10/11/2018 PRI (TST 5878) ASTM D1970 (adhesion) OCF-443-02-01 Service Confirmation Exp.08/21/2020 UL, LLC. (QUA 9625) Quality Assurance 4.1 Boral® TileSeal 50w is a nominal 50-mil thick, polyester -surfaced, self -adhering SB5 modified bitumen roof underlayment; meets ASTM D1970. 4.2 BoralO TileSeal"T is a nominal 60-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI 04-12. 4.3" BoraI8 MetaiSeal"T is a nominal 60-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D1970 and FR5A/TRI 04-12. 4.4 GatorSeal® is a nominal 55-mil thick, granular -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D1970. 4.5 Citadel® Plus is a nominal 48-mil thick, fabric -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen roofing underlayment for use as a base -layer in multi -ply underlayment systems; meets ASTM D1970. Evaluation Report M35710.12.10-R31 NEMO ET[, LLC FL14317-R30 certficote ofAuthonzation A32455 6TM EDITION 12017)FBC NON•HVRZ EVALUATION Revision 11: 10/12/2018 Boral Roof Underlayments; (602) 269-2288 Page 2 of 8 0 NEW I etc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P:E. aFe,in any way, the Designer - of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by -itself beneath the stated roof .... i,, Fn, m.dti-niv underlavment options. r 5.5.1 covers. Rums Lu u:c mxonou..�. �.�............_ ._....'—. �., -. -- TABLE 1i ROOF COVEROPTIONS Asphalt Adhesiveset Metal Slate Undedayment Shingles Nail -On Tile Tile lesBoral Ti Yes No No Yes Yes Boral TileSeal"r Yes Yes Yes Yes (See 5.5.1) lWaoakes Yes etalSealw Yes Yes Yes Yes (See 55.1)GatorSeal Yes Yes No No No Yes ._.._ ..... ..o a.u,...,t..e• A.,nmved title adhesives / underlayment combinations. - -Hunesrve-neLiuc unun.cuw..�.. ... ............o..r r'---- Florida Product Underlayments Adhesive Approval DAP Foam Touch'n Seal Stormeond Roof Tile Adhesive FL14506 Boral TileSeal"r or Boral MetalSealw DAP Foam Touch Seal StormBond 2Two-Component FL21374 Boral TileSealw or Boral MetalSeaPn Polyurethane Roof Tile Adhesive Dow TILE BOND'" Roof Tile Adhesive FL22525 Boral TileSeal"r or Boral MetaLSeal"r ICP Adhesives Polyset° AH-160 FL6332 Boral TileSeal"r or Boral MetalSeal"r ICP Adhesives Polyset® RTA-1 FL6276 Boral TileSeal"T or Boral MetalSeal"r ' Refer to Tile Manufacturer's orAdhesive Manufacturers Florida Product Approvaifor Overturning Moment Resistance Performance Evaluation Report M35710.SL30-R31 NEMO ETC, LLC FL14317-R30 eertifimm ofAuf madw d32455 6°i EDITION (2017) FBC NON-HVHZ EVALUATION Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018 Page 3 of 8 ' Refer to Tile Manufacturer's orAdhesive Manufacturers Florida Product Approvaifor Overturning Moment Resistance Performance Evaluation Report M35710.SL30-R31 NEMO ETC, LLC FL14317-R30 eertifimm ofAuf madw d32455 6°i EDITION (2017) FBC NON-HVHZ EVALUATION Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018 Page 3 of 8 NEW I etc. 5.6 Allowable Substrates: 5.6.1 Direct-Bondto Deck: Citadel Plus, Boral T1leSeal Sow, Boral TileSealn Boral MetalSealw or GatorSeal: ➢ Plywood (unprimed or primed with ASTM D41 primer). Boral TileSealw or Boral MetalSeal': ➢ OSB (unprimed or primed with ASTM D41 primer). Note. Refer to Section 5.6.4 for uplift limitations associated with direct deck underlayment installations where the overlying roof cover is adhesive -set tile roofing 5.6.2 Bond to Base Laver Underlavment: Citadel Plus, Boral TileSeal Son Boral TileSealln, Boral MetalSealw or GatorSeal: ➢ ASTM D226, Type 11 felt; Citadel Plus. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under adhesive -set tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC 1504.3.1. 5.6.3 Bond to Other Substrate Types: Citadel Plus, Boral TileSeal Soft, Boral TileSeaffT Boral MetalSealw or GatorSeal: ➢ ASTM D41 primed metal (e.g., flashing metal, valley metal, etc.). Boral TileSealw: ➢ Huber Zip Deck (unprimed or primed with ASTM D41 primer); Dens Deck Prime. Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. 5.6.4 Wind Resistance for Underlavment Systems in Adhesive -set Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath adhesive -set tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in adhesive -set tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads #1 Maximum Design Pressure=-120.0 post: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 to the plywood deck Base Ply: Citadel Plus, self -adhered Cap Sheet: Boral TileSealHTorBoral MetalSeallr,self-adhered, and back -nailed within the selvedge -edge side laps using 12 ga. x 1Y" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c. #2 Maximum Design Pressure=-242.51) Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Ply: None Cap Sheet: Boral TileSealw or Boral MetalSealwself-adhered and back -nailed within the selvedge -edge side laps using 12 ga. x lY" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c. MEMO ETC, ILC Evaluation Report M35710.12.10-R11 FL14317•R10 CeT'firote ofAuthonzabW#32455 6'v EDITION(20171 FBC NON•HVHZ EVALUATION Botal Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018 Page 4 of 8 ONEMOletc. #3 Maximum Design Pressure=-202.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having - Jurisdiction. Primer: Tropical Roofing Products #410 Quick Dry Primer or other ASTM D41 primer to the plywood deck Base Ply: None Cap Sheet: Boral TileSeal"T or Boral MetalSeaFrr, self -adhered, and back -nailed within the selvedge -edge side laps using 12 ga. x SY" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c. #4 Maximum Design Pressure=-210.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: KARNAK #89 Sta-Tak Primer to the plywood deck Base Ply: None Cap Sheet: Boral TileSeal"T or Boral MetalSeal"r, self -adhered, and back -nailed within the selvedge -edge side laps using 12 ga, x 1Y<" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c. #5 Maximum Design Pressure = -120.0 psf: Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: ASTM D41 to the concrete deck Base Ply: (Optional) Citadel Plus, self -adhered Cap Sheet: Boral TileSeal"T or Boral MetalSeal"r, self -adhered 5.6.4.1 Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design pressure requirements may not exceed -120 psf. 5.7 Exposure Limitations: GatorSeal shall not be left exposed for longer than 30-days after installation, prior to placement of final roof cover. Boral TileSeal 50"r, Boral TileSeal"T or Boral MetalSeal"r shall not be left exposed for longer than 180-days after installation, prior to placement of final roof cover. Citadel Plus, for use as a base -layer in a multi -ply underlayment system, shall not be left exposed for longer than 180-days after installation, prior to placement of subsequent underlayment layer. 5.8 Tile Slippage Limitations IFRSA/TRI April 2012 (04-12)1: When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as _ _,___ ,: :« «: , my hp pxrppdpd by using battens during loading of the roof tiles. Underlayment Tile le Staging Method Maximum Slope Boral TileSeal"r or Hat Max. 10-tile stack 6:12 Boral MetalSeal"r Lugged Max. 10-tile stack 6:127 6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Install self -adhering underlayment when ambient and surface temperatures are minimum 407 and rising. Evaluation Report M35710.12.10-R11 NEMO ETC, LLC FL14317-RID certificate ofAuthor&Won 432455 6" EDITION (2017) FBC NON-HVHZ EVALUATION Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018 Page 5 of 8 ONEMOletc. 6.4 I Citadel Plus: - -` 1 6.4.1 Citadel Plus is limited to use as abase or mid -layer in multi -ply underlayment systems beneath Boral TileSeal 50"r, Boral TileSealw or GatorSeal. 6.4.2 Slope limitations are those associated with the top -layer underlayment. 6.4.3 Direct to Deck: Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by Y-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the top edge of the sheet to the deck with corrosion resistant roofing nails, nails & tin -tags or 1-inch diameter plastic or steel cap nails spaced maximum 12-inch o.c. Overlap successive courses the entire width of the black -selvedge area, minimum 2 inches (horizontal lap) and minimum 6" end (vertical) laps. Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 50"r, Boral TleSeal"r, Boral MetalSeal'rt or GatorSeal. 6.4.4 To Base Sheet: Install base sheet of ASTM D226, Type 11 felt in accordance with Code requirements or install base ply of Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4.3 and when used as part of a multi -ply system. Install optional Citadel Plus as a mid -ply in accordance with Boral Roofing published installation instructions and Section 6.4.3. Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 5011T, Boral TileSeal"r or GatorSeal. Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design pressure requirements may not exceed -120 psf. 6.5 ` Bo'ral TileSeal 50"r- 6.5.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.5.2 Do not use Boral TileSeal 50111 on roof pitches less than 2:12. 6.5.3 Non -Tile Applications Direct to Deck: Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by Y<-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the black selvedge edge to the deck with corrosion resistant roofing nails, nails &tin -tags or 1-inch diameter plastic or steel cap nails spaced maximum 24-inch o.c. for slopes below 7:12 and maximum 12-inch o.c. for slopes 7:12 and greater. Overlap successive courses the entire width of the black -selvedge area, minimum 3-inch. Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam method detailed in Boral Roofing published installation instructions. NEMO ETC, LLC Evaluation Report M35710.12.10-R11 CerdPcote ofAvt#oon#32055 6" EDITION (2017) FBC NON-HVH2 EVALUATION FL14317-RIO h Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018 Page 6 of 8 SNEMOjetc. 6.5.4 Non -Tile Applications. to Base Sheet: Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus -in accordance with Boral Roofing published installation instructions and Section 6.4. Install Boral TileSeal SO"r in accordance over ASTM D226, Type li felt or Citadel Plus with Boral Roofing published installation instructions and Section 6.5.3, except end (vertical) laps, described below. Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in contact with the fabric top surface, rolling the interface into place with a weighted roller. 6.6 GatorSeal 6.6.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof coveringto be installed. 6.6.2 Do not use GatorSeal on roof pitches less than 2:12. 6.6.3 Non -Tile applications. Direct to Deck: Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by X-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the black selvedge edge to the deckwith corrosion resistant roofing nails, nails & tin -tags or 1-inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and greater. Overlap successive courses the entire width of the black -selvedge area, minimum 3-inch. Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous underside is in contact with the granular or mineral top surface, rolling the interface into place with a weighted roller, or using the Inverted Sheet Seam detailed in Boral Roofing published installation instructions. 6.6.4 Non -Tile Applications, to Base Sheet: Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4. Install GatorSeal overASTM D226,Type II felt or Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.6.3 except end (vertical) laps, described below. Apply SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous underside is in contact with the granular top surface, rolling the interface into place with a weighted roller. 6.7 BoraLTileSeal"T or Boral MetalSeai"T: 6.7.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.7.2 Do not use Boral TileSealw or Boral MetalSeal"r on roof pitches less than 2:12. 6.7.3 Non -Tile Applications. Direct to Deck: For OSB substrate, prime with ASTM D41 primer and allow to dry prior to installation. Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by Y-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1-inch diameter plastic or steel cap nails spaced maximum 12-inch o.c. Overlap successive courses the entire width of the black -selvedge area, minimum 3-inch. Seal under all end (vertical) laps using approved mastic or use Inverted Sheet Seam method detailed in Boral Roofing published installation instructions. NEMO ETC, LLC Evaluation Report W135710.22.10-R11 Certificate o)Authomavan A32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10 Boral Roof Underlayments; (602) 269-2289 Revision 11: 10/12/2018 Page 7 of 8 ONEW10letc. 6.7.4 Non -Tile Applications, to Base Sheet: Install-ASTM D226, Type II felt_in.accordance with Code requirementsorinstall-Citadel Plus inaccordancewith Boral Roofing published installation instructions and Section 6.4. Install Boral TileSeal"T or Boral MetalSeal"T over ASTM D226, Type II felt or Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.7.3, except end (vertical) laps, described below. Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in contact with the fabric top surface, rolling the interface into place with a weighted roller. . 6.7.5 Tile Applications: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRl April 2012 (04-12), Table 1. For adhesive -set tile applications, refer to Section 5.6.4 herein. Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design pressure requirements may not exceed -120 psf. Refer to Section 5.8 for tile staging limitations. Battens must be used for all tile installations atop Boral TileSeal"r or Boral MetalSeal"r with roof pitches of 2% to less than 3:12. Boral Roofing's Elevated Batten System or counter battens are required. As required bythe Building Official or Authority Having Jurisdiction in order to this product. NH UL, LLC. — QUA9625; (631) 546-2458; - END OF EVALUATION REPORT - installation of NEMO ETC, LLC Evaluation Report M35710.12.10-R31 Certificate ofAutAorizaoan A32455 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10 Boml Roof Undedayments; (602) 269-2288 Revision 11: 10/12/2018 Page 8 of 9 EXTERIOR RESEARCH & DESIGN, LLC. Certifcate of Authorization 99503 353 CHRISTIAN STREET, UNIT #13 T rt ROPA1HII `)J^ ERD OXFORD, CT 06478 PHONE:-(203)-262-9245- FAX: (203) 262-9243 EVALUATION REPORT Evaluation Report E10240.Og.Og-R4 East Coast Metals, Inc. FL5374-114 2301 West 8 Lane Date of Issuance: 09/03/2008 Hialeah, FL33010 Revision 4: D3/17/2015 SCOPE: This Evaluation Report is issued under Rule GIG20-3 and the applicable rules and regulations governing the use Of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential volume. The products d hSCANNED herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted BY DESCRIPTION: East Coast Metals Channel Metals St. Lucie County LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED coMpuANcE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify ea Robert ie complete rev ew a prod duct changes or the referenced Quality Assurance documentation changes. Trinity)ERD re relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityiERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection atthe job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. s9266, Florida OCA ANE3993 TAa l57' sealappeat...... uthamed tN Robert Nia.m.n, P.E ant➢n,, .15. Thu dam not serve as an efeamNr+RYsigned doWMVL IDthcnametl mm.iteedtotha CERTIFICATION OF INDEPENDENCE: ire or will it acquire, a financial interest in any company manufacturing o 1. Trinityl ERD does not have, nor does it intend to acqu distributing products it evaluates. 2. Trinityl ERD is not owned, operated or Controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. a financial interest in any other entity involved in the approval process o e 4. Robert Nieminen, P.E. does not have, nor will acquire, Product . ERD nor Robert Nieminen, P.E are, in any way, the Designer of Record for any 5. This is z building code evaluation. Neither Trinity) project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. � 4 1 L g :. 7 E La'tr— ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roofing Accessories that are an Integral Part of the Roofing System Compliance Statement East Coast Metals Channel Metals, as produced by East Coast Metals, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Pra a Standard Year 1507.3.7 Installation, non-HVHZ FRSA/TRI April 2012 (04-12) 2012 1518.8.1 Installation, HVHZ RAS 118, 119 & 120 1995 1523.65.2.2 Static Uplift Resistance TA5101 1995 1711.2.1 Static Uplift Resistance SBCCI SSTD 11 1997 3. REFERENCES: Enti Examination Reference Date ERD(TST6049) Static Uplift Resistance E42730.08.13 08/23/2013 ERD(TST6049) Static Uplift Resistance ECO-SC6795.1Z14-1 02/27/2015 ERD(TST6049) Static Uplift Resistance ECNI-SC6795.12.14.2 02/27/2015 Florida TEC (TST7393) TAS 301 530-628R 20/27/2010 PRI (TST5878) TA5101 ECM-001-02-02 09/23/2001 PRI(TST5878) TAS101 ECM-003-02-01 06/13/2008 PRI(TST5878) TAS101 EQd-004-02-01 06/13/2008 PRI (TST5878) TAS 101 ECIA-005-02-01 06/13/2008 PRI (TST5878) TA5101 ECM-006-02-01 06/13/2008 PRI(TST5878) TAS101 ECM-007-02-01 06/13/2008 PRI (TSTSB78) TAS 101 ECM-OOM2-01 06/13/2008 Florida Building Code Attachment Requirements FRSA/TRI April 2012104-12) 0412012 Florida Building Code -HVHZ Attachment Requirements RAS 118,119 and 120 1995 East Coast Metals Metal Quality MIR Certifications Various Architectural Testing (QUA1844) Quality Control Participation Letter Exp.12/31/2018 4. PRODUCT DESCRIPTION: 4.1 Hip & Ridge Channel Metal: Pre -formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof tile adhesive. Hip & Ridge Channel Metal is available in 119-3/8-inch (± 3/8-inch) length by 25, 3, 3.5, 4, 5, 6 or 7-inch L 3/8-inch) heights with 1.5-inch (_1/16-inch) deck -flanges. -Exterior Research and Design, U.C. Evaluation Report E10240.0E.08-R4 cereiFmte QFAvd erimtrae d9SW FL5374-R4 Revision 4: 03/17/2015 Page 2 of 7 RBN-PLf ERA 42 Trim Lock- Channel Metal: Pre -formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof tile adhesive. Trim Lock Channel Metal is characterized by its profiled and perforated upper horizontal flange designed to receive and allow for interlock with the overlying tile adhesive. Trim Lock Channel Metal is available in 119-3/8-inch (± 3/8") length by 3, 3.5, 4, 5 or 6-inch (± 3/8-inch) heights with 1.5-inch (} 1/16-inch) deck -flanges. G� 4.2 Trim Lock Plus Channel Metal: Pre -formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof tile adhesive. Trim Lock Plus Channel Metal is characterized by its profiled and perforated upper horizontal flange designed to receive and allow for interlock with the overlying tile adhesive and its perforated deck flanges, designed for installation atop the roof underlayment via placement in FBC Approved roof tile adhesive, which flows -through and interlocks with the underlying adhesive. Trim Lock Plus Channel Metal is available in 119-3/8-inch (±3/8") length by 3, 3.5, 4, 5 or 6-inch (±3/8-inch) heights with 1.5-inch I±1/16-inch) deck -flanges. 4.4 East Coast Metals Channel Metals are fabricated of the following metals: D Galvanized Steel: Min. 0.019±0.002-inch, ASTM A653 (G-90), min. 33 K51. Galvalume Steel: an. 0.019±0.002-inch, ASTM A792, A755, min. 35 KSI. D Aluminum: Min. 0.032 ± 0.002-inch, ASTM B209, 3003-1-134, min. 21 K51. D Stainless Steel: Miq. 0.019 ± o.o02-inch, ASTM A240/A480, T304, min. 35 K51. 5. LIMITATIONS: the Designer of 5.1 This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any '�Y. g Record for any project on which this Evaluation Report, or previous versions thereof, is/eras used for permitting or design guidance unless retained specifically for that purpose. Evaluation Report E10240.08.08-R4 Exterior Research and Design, I.I.C. FL5374-R4 r-enifimie OfAuthoruatlan 89503 Revision 4: 03/17/2015 Page 3 of 7 Tell [RD 5.2 FOR HVHZJURISDICTIONS: 5.2.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. For Trim Lock Plus Channel Metal, refer to the installation instructions herein. 5.2.2 For HVHZ jurisdictions, installations of Hip & Ridge Channel Metal and Trim Lock are prescriptive by RAS 118, 119 and 120, and the data In Tables 1A and 1B is supplemental to these prescriptive allowances. Installations of Trim Lock Plus are limited to projects having a required moment resistance (Mr) or uplift resistance (F,), as determined In accordance with RAS 127, not greater than the followingvalues. Referto the tile adhesive manufacturers published installation Instructions for adhesive paddy placement details. D "INDEPENDENT' paddy placement means each individual tile is bonded to the Channel Metal in its own, single foam paddy; tile head laps are not bonded. This method is limited to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to ultimate performance. D "INTERDEPENDENT" paddy placement means each individual file is bonded to the Channel Metal in a foam paddy, and a second foam paddy bonds the tile head lap, or two tiles are, bonded to the Channel Metal using a single foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1 margin of safety applied to ultimate performance. _ TAatE1A: PERFORMANCE LIMRATONs- HVHZ, INDEPENDENT PADDY PLACEMEUT (2 To 1 WRGM OFSAF1rVAWMDYAPPOED) Hip/Ridge Metal Tile Adhesive Allowable Performance Design Metal Type type Placement Moment Based Uplift Based Mr(ft-lbf) F'(Ibf) Hip &Ridge galvanized day or 3M"'2-Component Foam /ndepehdent 127 169 Channel Metal concrete Roof Tile Adhesive AH-150 Trim lurk galvanized, Galvalume", day or 3M^'2-Component Foam Independent 171 159 aluminum orstainless steel concrete Roof Tile Adhesive AH-160 Trim Lock Plus galvanized, Galvalumee, day or 310-2-Componem Foam Independent 177 1fi5 aluminum or stainless steel concrete Roof Tile Adhesive AH-160 _ TABLE IB: PERFORMANcE LLMITATIONs-HVHZ, INTERDEPENDENT PADDY PLACEMENT (4 To IA GLN aFSAFPTYALREADYAPPLiw) Hip/Ridge Metal Tile Adhesive Allowable Performance Moment Based Uplift Based Design Metal Type Type Placement Mr(ft-lbf) V(Ibf) Trim Lock or Trim galvanized, 1331valumee, day or 310-2-Component Foam Interdependent 95 88 Lock Pius aluminum or stainless steel concrete Roof Tile Adhesive AH-160 Trim Lock galvanized, Galvalumeo, clay or 3M"' Roof Tile Adhesive Interdependent 99 94 stainless steel concrete RTA-1 Trim Lock aluminum day or 310-Foam Roof Tile Interdependent 90 84 concrete 1 Adhesive RTA-1 Trim Lock Plus galvanized, Galvalumea, day or 3W Foam Roof Tile Interdependent 90 84 aluminum arstainiess steel concrete Adhesive RTA-1 Trim Lock galvanized, Galwlume or clay or TILE BOND'" Roof Tile Interdependent 123 117 stainless steel concrete Adhesive Trim Lock aluminum day or TILE BOND"' Roof Tile interdependent 79 73 concrete Adhesive Trim Lock Plus galvanized, Galvafumes, day or TILE BOND'" Roof Tile interdependent 79 73 aluminum orstainless steel concrete Adhesive Trim Lock galvanized, Galvalume"or day or Touch'n Seal StormBond Interdependent 146 139 stainless steel concrete Roof Tile Adhesive Trim Lock Aluminum day or Touch'n Seal StormBond Interdependent 58 54 concrete Roof Tile Adhesive Trim Lock Pius galvanized, Galvaiumeo, day or Touch'n seal StonnBond Interdependent 58 54 aluminum or stainless steel concrete Roof Tile Adhesive Exterior Research and Design, U.C. Evaluation Report E10240.08.08-114 Cerdpmte ofAuthomadon C9SD3 . FL5374-R4 Revision 4:03/17/2015 Page 4 of 7 RINM,° ERD 5.3 FOR NON-HVHZJURISDICnONS: 5.3.1 For Hip & Ridge Channel Metal or Trim Lack Channel Metal, refer to FRSA/TRI April 2012 (04-12). For Trim Lock Plus Channel Metal, refer to the installation instructions herein 5.3.2 For non-HVHZ, installations are limited to projects having hip and ridge design pressure requirements, determined in accordance with Table 3A'of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the tile adhesive manufacturer's published installation instructions for adhesive paddy placement details. `r "INDEPENDENT" paddy placement means each individual file is banded to the Channel Metal in its own, single foam paddy, tile head laps are not bonded. This method is limited to 2-part tile adhesives. This method is limited to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to ultimate performance. D "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy, and a second foam paddy bonds the file head lap, or two tiles are bonded to the Channel Metal using a single foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1 margin of safety applied to ultimate performance. TABLE2A: PERFORMANCELLMITATIONs—NON-HVHZ,INDEPENDENTPADDYPLACEMENT (2TOI MARGINOFSAFETYALRFAOYAPPUEO) Hip/Ridge Metal Title Adhesive Allowable Uplift (Psf) Design Metal Type .fie Placement Hip & Ridge galvanized day or 3M'" 2-Component Foam Roof Independent p 169 Channel Metal concrete Tile Adhesive AH-160 Trim Lock galvanized, Galvalumee, aluminum or clay or 3M"' 2-Component Foam Roof Independent 173 stainlesssteel concrete Tile Adhesive AH-160 Trim Lock Plus galvanized, Galvalume°, aluminum or day or 3M"' 2-Component Foam Roof Independent 178 stainlesssteel concrete Tile Adhesive AH-160 IABLE23: PERFORMANCE ILMITIrnONs—NON-HVHZ, INTERDEPENDENT PADDY PLACEMENT (4TO 1WRG/NOFSAFFLYALRFADYAPPNtD) " Hip/Ridge Metal Tile Adhesive Allowable Uplift (Psf) Design Metal Type Type Placement Trim Lock or Trim galvanized, Galvalume", aluminum or day or 3M'" 2-Component Foam Roof Interdependent 98 Lock Plus stainless steel concrete Tile AdhesiveAH-160 galvanized, Galvalume orstainless clay or 3M'" Foam Roof Tile Adhesive Interdependent 110 Trim Lock steel concrete RTA-1 day or 3M"' Foam Roof Tile Adhesive Interdependent 93 Trim lock aluminum concrete RTA-1 galvanized, Galvalume, aluminum or day or 3M'" Foam Rool"M eAdhesive Interdependent p 93 Trim Lock Plus stainless steel concrete RTA-1 Trim Lock galvanized, Galvalume° orstainless clay or TILE BOND— Roof Tile Adhesive Interdependent 152 steel concrete Trim Lock aluminum clay or TILE BOND— RoofTde Adhesive interdependent 82 concrete Trim Lock Plus galvanized, Galvalume', aluminum or clay or TILE BOND'" Roof Tile Adhesive Interdependent 82 stainless steel concrete galvanized, Galvalume' orstainless day or Touch'n Seal StormHond Roof Interdependent 148 Trim Lock steel concrete Tile Adhesive day or Touch'n Seal StormBond Roof Interdependent 61 Trim lock Aluminum concrete Tiie Adhesive galvanized, Galvalume°, aluminum or clay Or Touch'n Seal Stormoond Roof Interdependent 61 Trim Lock Plus stainless steel concrete Tile Adhesive Exterior Research and Design, LLG Evaluation Report E10240.08.08-R4 CzMTmre O7AurADdredan R9sM FLS374-114 Revision 4: 03/17/2015 Page 5 of 7 TRWITY ERD 6. INSTALLATION: 6.1 The roof deck shall be minimum 15/32-inch plywood (non-HVHZ) or minimum 19/32-inch plywood (HVHZ) attached in accordance with FBC Chapter 23 to the satisfaction of the AHJ. 6.2 Hip & Ridge Channel Metal and Trim Lock Channel Metal shall be installed using min. 11 ga. x 1Y,-inch long x 3/8-inch head diameter galvanized annular ring shank nails spaced 6-inch o.c. along both deck -flanges. Fasteners shall be positioned Y-inch from the outside edge of each deck -flange, set in a bed plastic roof cement. For FBC HVHZ, refer to FBC RAS 218, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. 6.3 Trim Lack Plus Channel Metal shall be installed atop the Approved roof underiayment in continuous 2-inch wide ribbons of tile adhesive centered beneath each 1.5-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet adhesive and allow it to set-up prior to installation of roof tiles. View of Polyset AH160 Placementfor Trim Lock Plus Channel Metal Installation 63.1 It is critical that the bond between the Trim Lock Plus Channel Metal, the tile adhesive and the underiayment is not disturbed prior to or during placement of the ridge tiles. 6.3.2 Approved underlayments are the codified '30/90' system or other FBC Approved roof underlayments listing approved use of the subject file adhesive. Eaerler Research and Design, r Evaluation Report e10240.08.08-R4 FL5374 4 Certlflcore ofAurhariza8an #9503 Revision 4: 03/17/2015 Page 6 of 7 WNW �f ERE) 6.4 Tile shall be installed. atop. the Channel Metal in accordance with the tile. adhesive. manufacturer's Approved, published installation instructions, subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (04-12) or RAS 116, RA5119, RA512O requirements. Hip / Ridge Tile Tile Adhesive Trim Lock Plus Mortar or Weather Block Adhesive Tile Adhesive View of Trim Lock Plus Channel Metal installation after Weather Blocked 6.4.1 Channel Metal shall be free of dust, debris, oils or other bond -breaking substance prior to placement of adhesive. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. R. MANUFACTURING PLANTS: Contact the named CIA entity for manufacturing facilities covered by FA.0 Rule 61G20-3 QA requirements. 9. QUAUTYAssURANCE ENTITY: Architectural Testing, Inc — QUA1844� (717) 764-7700 - END OF EVALUATION REPORT - Exterior Research and Design, LLC Evaluation Report E10240.011.09-114 hrd'?.ft oJrAnh.& don"543 FL5374-R4 Revision 4: 03/17/2015 Page 7 of 7