EVALUATION REPORT
r.NTCGRA
R O O F T I L E
Entegra Roof Tile, LLC
1289 NE 9th Avenue
Okeechobee, FL34972
(602)515-6933
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the
construction materials in the State of Florida. The documental
P.E. for use of the product under the Florida Building Code
products described herein have been evaluated for complial
(HVHZ) sections noted herein.
DESCRIPTION: Entegra Concrete Roof Tiles (HVHZ
LABELING: Labeling shall be in accordance with the
herein.
EXTERIOR RESEARCH & DESIGN, U.C.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
(203)262-9245
Evaluation Report E39310.11.11-1-R4
FL7804-R30
Date of Issuance:12/02/2011
Revision 4: 10/17/2017
Dlicable rules and regulations governing the use of
submitted has been reviewed by Robert Nieminen,
d Florida Building Code, Residential Volume. The
with the 6 h Edition (2017) Florida Building Code
SCANNED
BY
St. Lucie County
is the Accredited Quality Assurance Agency noted
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or proYisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityIERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity(ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report isdisplayed , then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The far bofle seal appndng was aalloriaed by Robert Nie nWen,
P.L on 10117/2017. This does noturye as an eleaaNady signed
damment. Signed, sealed hardmpies have been taiamitled to the
Pmdua Approval Adminutrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity] ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being Issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity] ERD nor Robert 4ieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereo , is/was used for permitting or design guidance unless retained
-- specifically -for- that purpose. ---- ---- —
TRINITY iERD
ROOFING SYSTEM EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roofing Tiles
Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated
compliance with the following sections of the Fl Irida Building Code through testing in accordance with the following
Standards. Compliance is subject to the installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section
1523.6.5.2
1523.6.5.2
1523.6.5.2.2
1523.6.5.2.3
1523.6.5.2.3
3. REFERENCES:
Enti
ERD(TST6049)
ATL(TST3782)
ATL (TST3782)
ATL(TST3782)
ATL (TST3782)
ATL (TST 3782)
ATL (TST 3782)
ATL (TST 3782)
ATL (TST 3782)
ATL (TST 3782)
Miami -Dade (CER1592)
Miami -Dade (CER1592)
Miami -Dade (CER1592)
Miami -Dade (CER1592)
Miami -Dade (CER1592)
Tile Roof Institute
PRI (QUA9110)
Exterior Research and Design, U.C.
CeB/lrote ofAuthanrution 09503
Property
Standard
Year
Physical Properties
TAS 112
1995
Wind Driven Rain
TAS 100
1995
Static Uplift Resistance
TAS 101
1995
Static Uplift Resistance
TAS 102
1995
Static Uplift Resistance
TAS 102(A)
1995
Examination
Reference
Date
TAS 101
P39740.02.12
02/21/2012
Physical Properties
RT0624.05-14
07/03/2014
Physical Properties
RT0624.04-14
07/07/2014
Physical Properties
RT1210.02-15
12/17/2015
Physical Properties
RT1210.03-15
12/17/2015
Physical Properties
RT1103.01-15
11/07/2015
Physical Properties
RT1103.02-15
11/07/2015
Physical Properties
RT1103.03-15
11/07/2015
Physical Properties
RT1103.04-15
11/07/2015
Physical Properties
RT1103.05-15
11/07/2015
HVHZ Compliance
14-0416.12
11/27/2014
HVHZ Compliance
15-0721.04
11/05/2015
HVHZ Compliance
16-0112.06
02/25/2016
HVHZ Compliance
16-0112.07
02/25/2016
HVHZ Compliance
16-0112.08
02/25/2016
TAS 100, TAS 101, 102, 302(A)
Membership Confirmation
Current
Quality Assurance
Service Confirmation
Exp.11/02/2018
Evaluation Report E39310.11.11-1-R4
6'EDITION (2017) FBC HVHZ EVALUATION FL7804-R30
Entegra Roof Tiles Revision 4: 10/17/2017
Page 2 of 8
a.
TRINITY' ERD
17A5 1A 7. Tvna 3a (flat-nrnfilel� ��—� I I BERMUDA FAT. PLANTATION FLIT anL[.HORIZON FLAT
Is,
Be
Horizon Flat
Exterior Research and Design, Ur I Evaluation Report E39310.11.11-1-R4
Certifitote o7Autho. .don 09503 6.EDITION (2017) FDC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles, Revision 4:10/17/2017
Page 3 of 8
TRINITY ERD
4.2
TAS 112, Type la (interlocking;Ihigh-profile)
BELLA HIGH, "S"
1
13-4"
Bella
High "S"
4.3
TAS112, Type lb (interlocking, low-pro£Ie)
. ESTATE"S" and HACIENDA
Nail Holes T
ra
16.
i
Estate "S"
�
Hacienda
4-3TA5112,
Type 2a (non -interlocking, highL,profile)
GALENASPANISH"S" and REGAL
f
a
\_
17"
a Ur10" Y
Galena Spanish "S"
Regal
Exterior Research and Design, I.I.C. IEvaluation Report E39310.11.11-1-114
Dernfimte oJAuthori+ation 49503 da' EOITION 12017J FOC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 4 of 8
I TRINI IY i ERD
S. LIMITATIONS:
-5.1 - This is a building code evaluation: --Neither Trini y)ERD-nor Robert Nieminen, P.E. are,, in anyway, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or others adopting FBC HVHZ requirements.
5.3 Fire classification is not part of this evaluation; refer to FBC 1516 or listing by an approved testing agency for
fire rating of this product.
5.4 Reference is made to FBC 1512.4.2.4 regarding field testing of completed tile roof installations.
5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in
accordance with TAS 112, AppendixA,
5.6 Minimum underlayment shall comply with the RAJ 118, RAS 119 or RAS 120, as applicable. Underlayment
products shall hold current Florida Statewide Product Approval or Local Approval for use in the roof
assemblies in FBC HVHZ jurisdictions. i
5.7 Minimum roof deck requirements shall be in accordance with. applicable FBC HVHZ requirements.:
5.8 All products in the roof assembly shall have quality assurance audit in accordance with the F.A.C. Rule
61G20-3.
6. INSTALLATION:
6.1 Entegra Concrete Roof Tiles may be mechanically1 fastened, mortar -set or adhesive -set. Installation shall
comply with manufacturers current published (nst�'uctions, but not less than the requirements of RAS 118,
RAS 119 or RAS 120, as applicable.
6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment -Based System' in
accordance with Roofing Application Standard RASI127-11 using the data outlined herein. ,
- - .TABLE_ 1: AERODYNAMIC MULTIPUERS-7,(w)
,
Tile
Batten Application
Direct -Deck Application
Bermuda Flat
0.189
0.205
Plantation Flat
0.267
0.289
Horizon Flat
0.305
0.330
Bella High "S"
0.349
0.378
Estate "S"
0.267
(
0.289
Hacienda
0.267
0.289
Galena Spanish "S"
N/A
0.235
Regal
0.287
0.311
' TABLE 2:RESTORING. MOMENT DUE
!no GRAVITY-M,(FT-LBF)
Roof
Slope (0)
Tile
2:12<0<3:12
3:12<0<4:12
4:12<0<5::12
5:12<0<6:12
6:12<0<7:12
0>7:12
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Bermuda Flat
5.22
6.43
5.17
6.37
5.09
6127
4.98
6.15
4.86
6.00
4.72
5.83
Plantation Flat
7.22
7.91
6.85
7.79
6.75
7167
6.61
7.52
6.44
7.32
6.25
7.04
Horizon
7.60
8.32
7.52
8.24
7.41
8112
7.26
7.95
7.09
7.76
6.89
7.55
Bella High "5"
6.19
6.89
6.11
6.80
5.99
6167
5.85
6.51
5.68
6.33
5.50
6.13
Estate "S"
6.14
6.84
5.91
6.74
5.82
6164
5.70
6.50
5.56
6.33
5.40
6.14
Hacienda
5.92
6.80
5.92
6.80
5.82
6;69
1 5.70
6.55
5.56
6.39
5.41
6.22
Galena Spanish"S"
N/A
6.20
N/A
6.13
N/A
603
N/A
5.89
N/A
5.74
N/A
5.57
Regal
7.77
8.34
7.77
8.34
7.65
8..20
7.49
8.03
73 0
7.83
7.10
7.61
Exterior Research and Design, U.C. I
Ceniiimte o)Authonratlon A9503 OEDmON(2017) FBC HVHZ EVALUATION
Entegra Roof Tiles
Evaluation Report E39310.11.11-1-R4
FL7804-R10
Revision 4: 10/17/2017
Page 5 of 8
r�
1 TRINITY ERD
TABLE 3A: ATTACHMENT RESI"CE
-MECHANIC4LLYATTACHED
EXPRESSED AS,A MOMENT -MF(FT-LBF) ,
SYSTEMS- -
Tile
Fastener
Direct -Deck
(min. 15/32"
,plywood)
Direct -Deck
(min. 19/32"
plywaodl
Battens
Type
If
Size
r Shank
Gip
Nail
One (1)
10d
Smooth or Screw
N/A
7.3
9.8
4.9
Nail
Two (2)
10d
Smooth or Screw
N/A
14.0
18.8
7.4
Nail
One (1)
30d
Smooth or Screw
Eave
19.0
19.0
22.1
Nail
One (1)
10d
Smooth cr5crew
Field
24.3
24.3
24.2
Nail
Two (2)
iod
I Smooth or5crew
Eave
31.9
31.5
34.8
Flat,
Iantad Flator
Nail
Two (2)
10d
Smooth or Screw
Field
35,5
35.5
34.8
Ho n
Nail
Two (2)
10d
Ring
N/A
30.9
38.1
17.2
Nails
Two(2)1
Sods
I Ringr
N/A
50.3'
65.5'
48.3'
Screw
One (1)
#8
N/A
N/A
30.8
30.8
18.2
crew
Two (2)
NS
N/A
N/A
51.7
51.7
24.4
'Installation with a 4-inch tile headlap and
fasteners located min. 2%-Inch from head of tile.
Nail
One (1)'
10d
Smooth orSaew
N/A
8.8'
11.8'
4.1'
Nail
Two (2)
10d
Smooth or Screw
N/A
16.4
21.9
7.1
Nail
One (1)'
SOd
Smooth or Screw
Eave
19.0'
19.0'
22.1'
Nail
One (1)'
30d
Smooth or5crew
Field
24.3'
24.3'
24.2s
Nail
Two (2)
10d
Smooth or Screw
Eave
31.9
31.9
32.2
Nail
Two (2)
iod
I Smooth or5crew
Field
35.5
35.5
34.8
Estate "S" or Hacienda
Nail
Two (2)
lOd
Ring
N/A
27.8
37.4
28.8
Nail'
Two
10d'
I Ring'
N/A
43.0'
67.5'
50.91
Screw
One(1)2
#8
I N/A
N/A
25.81
25.8'
22.92
Screw
Two (2)
#8
N/A
NIA
47.1
47.1
49.1
' Installation with a 4-Inch tile headlap andlifasteners
looted min. 2%-inch from head of tile.
'For one (2) fastener installations, utilize hole
that is approximately 4Y-inch from the Interlocking edge.
Nail
One (1)
10d
I
Smooth or Screw
N/A
5.1
6.8
2.8
Nail
Two (2)
10d
Smooth or Screw
N/A
6.9
9.2
7.3
Nail
One(1)
30d
I
Smooth or Screw
Field
23.1
23.1
19.0
Nail
One (1)
10d
I
Smoothor5crew
Eave
29.3
29.3
24.0
Nail
Two (2)
10d
Smooth or Screw
Field
27.6
27.6
38.6
Bella High "S", Galena
Nail
Two (2)
10d
Smooth or Screw
Eave
38.1
38.1
41.8
Spanish "S" or Regal
Nall
Two (2)
SOd
Ring
.2
19.4
Nail,
Two (2)'
10d'
Ring'
WNIA20.7
11
509'
Screw
One (1)
NB
l
N/A
.7
18.1
Screw
Two (2)
#8
N/A
.2
29.8
1Installation with a 4-inch rile headlap and
fasteners located min. 2%-inch from head of tile.
Exterior Research and Design, U.C. Evaluation Report E39310,11,11-1-114
certf/hate of Authorization#9503 61M EDITION(2017) FBC HVNZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4: 10/17/2017
Page 6 of 8
,I 'T'RINIIY ERD
- - ----- TABLE 4:-ATTACHMENT-RESISTANCEE%PRE4ED AS A' MOMENT -MF(FT-LBF) - -- -----
- MORTAR AND ADHESIVE -SET SYSTEMS - -
Note from Entegra Roof Tile, LLC.: The performance data listed in Tattle 4.are based on therespective' adhesive -manufacturers' test
reports and Miami -Dade NOAS. Entegra Roof rile, LLC relies upon the adhesive manufacturers to provide these values for our inclusion
in this FBC. HVHZ Evaluation Report.. Please consult the individual adhesive manufacturer for informotion on product approvals,
limitations, revisions or other information for determining wind load and overturning momentperformance.
Tile Adhesive
Tile
Product
ProductlApproval
Placement
Mf (ft-lbf)
"TILE BOND'"" by Dow Chemical
NOA 1G-0222.01
Interdependent (2-paddy)
41
Bermuda
'Touch N' Seal Storm Bond" by DAP Foam
NOA ld',-0421.03
Interdependent (2-paddy)
73
Flat,
"polyset° RTA-1" by ICP Adhesives &Sealants
NOA 16-0315.03
'
Interdependent (2-paddy)
52
Plantation
Flat
n
Horizon
"Polyset®AH-160" by ICP Adhesives &
Sealants
NOA 17I-0322.03
Interdependent (2-paddy)
43
Independent (medium paddy, -30 g)
51
Independent (large paddy,-45 g)
92
'TILE BOND"'" by Dow Chemical
NOA ifi-0222.01
Interdependent (2-paddy)
44
'Touch N' Seal Storm Bond" by DAP Foam
NOA 1d-0421.03
Interdependent (2-paddy)
42
"5"
"Polyset® RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
44
Estate or
Hacienda
"Polyset° AH-160" by ICP Adhesives &
Sealants
NOA 1
i
0322.03
Interdependent (2-paddy)
50
Independent (medium paddy, -30 g)
37
Independent (large paddy,-54 g)
61
Mortar
Various
Per RAS 120
21
'TILE BOND'"" by Dow Chemical
NOA 1fi-0222.01
Interdependent (2-paddy)
48
'Touch N' Seal Storm Bond" by DAP Foam
NOA 1G-0421.03
Interdependent (2-paddy)
52
Bella High
"S",
"Polyset® RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
36
Galena
Spanish "5"
or Regal
"Polyset® AH-160" by ICP Adhesives &
Sealants
NOA 1i-0322.03
Interdependent (2-paddy)
30
Independent (medium paddy,-30 g)
49
Independent (large paddy, `63 g)
94
Mortar
Various
Per RA5120
25
7. LABELING:
7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed
below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance
Agency noted herein.
land/or
ERR u
"5'_", Galena SRanish_'S"
Exterior Research and Design, LLC. i Evaluation Report E39310.11.11-1-R4
CenifimteofAuthodroaon 09503 6'"EDITION(2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof riles Revision 4: 10/17/2017
s Page 7 of 8
TRINITY ERD
Hanson
Labeli g: Horizon Flat, Hacienda, Regal
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority aving Jurisdiction in order to properly evaluate the installation of
this product.
9.
MANUFACTURING PLANTS:
Plant
Profilei* ,
Okeechobee, FL
Bermuda Flat, Plantation
Flat, Estate "5", Bella High "5", Galena Spanish "S"
Ft. Myers, FL
Horizon Flat, Hacienda
Deerfield Beach, FL
Horizon Flat, Hacienda, Regal
10. QUALITY ASSURANCE ENTITY:
PRI Construction Materials Technologies, LLC. — i UA9310; (813) 621-5777
- END OF EVALUATION REPORT —
Exterior Research and Design, U.C.Evaluation Report E39310.11.11-1-R4
rertl(7rnte o)Authorlmtion a9503 Gr" EDITION(2017) FBC HVHZ EVALUATION FL7804-ft10
Entegra Roof Tiles Revision 4:10/17/2017
Page 8 of 8
RECEIVED
FFg 21 1018
permitting Department NEORECta.
St. Lucie County
Certificate of Authorization N32455
to 353-Christian-Street,.Unit #13-
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
Boral Roofing
7575 , CA. Center Drive, Suite 100 FILE C 0 PY
Irvine, A92618
(602)269-2288
on Report M35710.12.30-Ril
FL14317-R10
Date of issuance:12/21/2010
Revision 11:10/12/2018
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
described herein have been evaluated for compliance with the 6w Edition (2017) Florida Building Co I IV S-noted
herein. BY
DESCRIPTION: Boral Roof Underlayments St. Lucie County
LABELING: labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO ietc. Evaluated" may be displayed in
advertising literature. if any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPErnON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
n„.y,,,,-."
; *� i ��'• • ;-,, .,
"%�"'•
Thefaalmile seal appearing was authorized by Robert
Robert J.M. Nieminen, P.E.
i-..'•�,
Wemnen,P.Eon10/12/20MThis doesnot semeasan
Florida Registration No. 59166, Florida OCAANE7983
,,.. ;, .....•.
eectron;miry signeddocument
CERTFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
—product
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record orany
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
NNEMOletc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Boral Roof Underlayments, as marketed by Boral Roofing, have demonstrated
compliance with the following sections of the 6t6 Edition (2017) Florida Building Code through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations
/ Conditions of Use set forth herein.
Section
Property
manuaru
—
2012
1504.3.1
1507.1.1, T1507.1.1,
Wind Uplift
Physical Properties
UL 1897
ASTM D1970
2015
1507.2.9.2
1507.3.3
Physical Properties
FRSA/TRI April 2012 (04-12)
2012
Enti
Examination
Reference
Date
o9/30/2011
ERD (TST 6049)
Physical Properties
M36790.07.11
08/28/2012
ERD (TST 6049)
Physical Properties
Tensile Adhesion / LTA
B40380.08.12
C41420.09.12-2
09/11/2012
ERD (TST 6049)
ERD (TST 6049)
Adhesion
841940.09.12
09/13/2012
2014
09//04/201
ERD (TST 6049)
Tensile Adhesion / LTA
B4739D.07.14-1
ERD (TST 6049)
Tensile Adhesion / LTA
347390.09.14
11/2/2017
OC (PDM1838)
Physical Properties
Equivalency statement
027/2010
12/03
PRI (TST 5878)
ASTM D1970
NEI-031-02-02:REV
NEI-029-02-01:REV
1 //2010
PRI (TST 5878)
PRI (TST 5878)
ASTM D1970
Tensile Adhesion / LTA
NEI-046-02-01REV
12/17/2010
PRI (TST5878)
FRSA/TRI April 2012
NEI-076-02-01
02/14/2011
01/29/2013
PRI (TST 5878)
ASTM D1970
Wind Uplift
NEI-034-02-02
BORR-001-02-01
03/17/2015
PRI (TST 5878)
PRI (TST 5878)
Wind Uplift
BORR-005-02-01
06/24/2015
PRI (TST 5878)
Tensile Adhesion / LTA
DAPF-002-02-01
03/08/2018
10/11/2018
PRI (TST 5878)
ASTM D1970 (adhesion)
OCF-443-02-01
Service Confirmation
Exp.08/21/2020
UL, LLC. (QUA 9625)
Quality Assurance
4.1 Boral® TileSeal 50w is a nominal 50-mil thick, polyester -surfaced, self -adhering SB5 modified bitumen roof
underlayment; meets ASTM D1970.
4.2 BoralO TileSeal"T is a nominal 60-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI 04-12.
4.3" BoraI8 MetaiSeal"T is a nominal 60-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment; meets ASTM D1970 and FR5A/TRI 04-12.
4.4 GatorSeal® is a nominal 55-mil thick, granular -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen
roof underlayment; meets ASTM D1970.
4.5 Citadel® Plus is a nominal 48-mil thick, fabric -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen
roofing underlayment for use as a base -layer in multi -ply underlayment systems; meets ASTM D1970.
Evaluation Report M35710.12.10-R31
NEMO ET[, LLC FL14317-R30
certficote ofAuthonzation A32455 6TM EDITION 12017)FBC NON•HVRZ EVALUATION Revision 11: 10/12/2018
Boral Roof Underlayments; (602) 269-2288 Page 2 of 8
0
NEW I etc.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P:E. aFe,in any way, the Designer -
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for
fire ratings of this product.
5.4 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by -itself beneath the stated roof
.... i,, Fn, m.dti-niv underlavment options.
r
5.5.1
covers. Rums Lu u:c mxonou..�. �.�............_ ._....'—. �., -. --
TABLE 1i ROOF COVEROPTIONS
Asphalt Adhesiveset Metal
Slate
Undedayment Shingles Nail -On Tile Tile
lesBoral
Ti
Yes No
No Yes
Yes
Boral TileSeal"r
Yes Yes
Yes Yes
(See 5.5.1)
lWaoakes
Yes
etalSealw
Yes Yes
Yes Yes
(See 55.1)GatorSeal
Yes
Yes No
No No
Yes
._.._ ..... ..o a.u,...,t..e• A.,nmved title adhesives / underlayment combinations.
-
-Hunesrve-neLiuc unun.cuw..�.. ... ............o..r r'----
Florida Product Underlayments
Adhesive Approval
DAP Foam Touch'n Seal Stormeond Roof Tile Adhesive FL14506 Boral TileSeal"r or Boral MetalSealw
DAP Foam Touch Seal StormBond 2Two-Component FL21374 Boral TileSealw or Boral MetalSeaPn
Polyurethane Roof Tile Adhesive
Dow TILE BOND'" Roof Tile Adhesive FL22525 Boral TileSeal"r or Boral MetaLSeal"r
ICP Adhesives Polyset° AH-160 FL6332 Boral TileSeal"r or Boral MetalSeal"r
ICP Adhesives Polyset® RTA-1 FL6276 Boral TileSeal"T or Boral MetalSeal"r
' Refer to Tile Manufacturer's orAdhesive Manufacturers Florida Product Approvaifor Overturning Moment Resistance Performance
Evaluation Report M35710.SL30-R31
NEMO ETC, LLC FL14317-R30
eertifimm ofAuf madw d32455 6°i EDITION (2017) FBC NON-HVHZ EVALUATION
Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018
Page 3 of 8
' Refer to Tile Manufacturer's orAdhesive Manufacturers Florida Product Approvaifor Overturning Moment Resistance Performance
Evaluation Report M35710.SL30-R31
NEMO ETC, LLC FL14317-R30
eertifimm ofAuf madw d32455 6°i EDITION (2017) FBC NON-HVHZ EVALUATION
Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018
Page 3 of 8
NEW I etc.
5.6 Allowable Substrates:
5.6.1 Direct-Bondto Deck:
Citadel Plus, Boral T1leSeal Sow, Boral TileSealn Boral MetalSealw or GatorSeal:
➢ Plywood (unprimed or primed with ASTM D41 primer).
Boral TileSealw or Boral MetalSeal':
➢ OSB (unprimed or primed with ASTM D41 primer).
Note. Refer to Section 5.6.4 for uplift limitations associated with direct deck underlayment installations where the
overlying roof cover is adhesive -set tile roofing
5.6.2 Bond to Base Laver Underlavment:
Citadel Plus, Boral TileSeal Son Boral TileSealln, Boral MetalSealw or GatorSeal:
➢ ASTM D226, Type 11 felt; Citadel Plus.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under adhesive -set tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested
in accordance with FBC 1504.3.1.
5.6.3 Bond to Other Substrate Types:
Citadel Plus, Boral TileSeal Soft, Boral TileSeaffT Boral MetalSealw or GatorSeal:
➢ ASTM D41 primed metal (e.g., flashing metal, valley metal, etc.).
Boral TileSealw:
➢ Huber Zip Deck (unprimed or primed with ASTM D41 primer); Dens Deck Prime.
Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval.
5.6.4 Wind Resistance for Underlavment Systems in Adhesive -set Tile Applications: FRSA/TRI April 2012 (04-12) does
not address wind uplift resistance of all underlayment systems beneath adhesive -set tile systems, where the
underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems
that are not addressed in FRSA/TRI April 2012 (04-12) and are used in adhesive -set tile applications. Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the
ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer
to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads
#1 Maximum Design Pressure=-120.0 post:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional) ASTM D41 to the plywood deck
Base Ply: Citadel Plus, self -adhered
Cap Sheet: Boral TileSealHTorBoral MetalSeallr,self-adhered, and back -nailed within the selvedge -edge side laps
using 12 ga. x 1Y" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c.
#2 Maximum Design Pressure=-242.51)
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Ply: None
Cap Sheet: Boral TileSealw or Boral MetalSealwself-adhered and back -nailed within the selvedge -edge side laps
using 12 ga. x lY" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c.
MEMO ETC, ILC Evaluation Report M35710.12.10-R11
FL14317•R10
CeT'firote ofAuthonzabW#32455 6'v EDITION(20171 FBC NON•HVHZ EVALUATION
Botal Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018
Page 4 of 8
ONEMOletc.
#3 Maximum Design Pressure=-202.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having -
Jurisdiction.
Primer: Tropical Roofing Products #410 Quick Dry Primer or other ASTM D41 primer to the plywood deck
Base Ply: None
Cap Sheet: Boral TileSeal"T or Boral MetalSeaFrr, self -adhered, and back -nailed within the selvedge -edge side laps
using 12 ga. x SY" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure=-210.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: KARNAK #89 Sta-Tak Primer to the plywood deck
Base Ply: None
Cap Sheet: Boral TileSeal"T or Boral MetalSeal"r, self -adhered, and back -nailed within the selvedge -edge side laps
using 12 ga, x 1Y<" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c.
#5 Maximum Design Pressure = -120.0 psf:
Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: ASTM D41 to the concrete deck
Base Ply: (Optional) Citadel Plus, self -adhered
Cap Sheet: Boral TileSeal"T or Boral MetalSeal"r, self -adhered
5.6.4.1 Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf.
5.7 Exposure Limitations:
GatorSeal shall not be left exposed for longer than 30-days after installation, prior to placement of final roof cover.
Boral TileSeal 50"r, Boral TileSeal"T or Boral MetalSeal"r shall not be left exposed for longer than 180-days after
installation, prior to placement of final roof cover.
Citadel Plus, for use as a base -layer in a multi -ply underlayment system, shall not be left exposed for longer than
180-days after installation, prior to placement of subsequent underlayment layer.
5.8 Tile Slippage Limitations IFRSA/TRI April 2012 (04-12)1:
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as
_ _,___ ,: :« «: , my hp pxrppdpd by using battens during loading of the roof tiles.
Underlayment Tile le Staging Method Maximum Slope
Boral TileSeal"r or Hat Max. 10-tile stack 6:12
Boral MetalSeal"r Lugged Max. 10-tile stack 6:127
6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Install self -adhering underlayment when ambient and surface temperatures are minimum 407 and rising.
Evaluation Report M35710.12.10-R11
NEMO ETC, LLC FL14317-RID
certificate ofAuthor&Won 432455 6" EDITION (2017) FBC NON-HVHZ EVALUATION
Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018
Page 5 of 8
ONEMOletc.
6.4 I Citadel Plus: - -` 1
6.4.1 Citadel Plus is limited to use as abase or mid -layer in multi -ply underlayment systems beneath Boral TileSeal 50"r,
Boral TileSealw or GatorSeal.
6.4.2 Slope limitations are those associated with the top -layer underlayment.
6.4.3 Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by Y-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the top edge of the sheet to the deck with corrosion resistant roofing nails, nails & tin -tags or 1-inch
diameter plastic or steel cap nails spaced maximum 12-inch o.c. Overlap successive courses the entire width of the
black -selvedge area, minimum 2 inches (horizontal lap) and minimum 6" end (vertical) laps.
Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 50"r, Boral
TleSeal"r, Boral MetalSeal'rt or GatorSeal.
6.4.4 To Base Sheet:
Install base sheet of ASTM D226, Type 11 felt in accordance with Code requirements or install base ply of Citadel
Plus in accordance with Boral Roofing published installation instructions and Section 6.4.3 and when used as part
of a multi -ply system.
Install optional Citadel Plus as a mid -ply in accordance with Boral Roofing published installation instructions and
Section 6.4.3.
Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 5011T, Boral
TileSeal"r or GatorSeal.
Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf.
6.5 ` Bo'ral TileSeal 50"r-
6.5.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.5.2 Do not use Boral TileSeal 50111 on roof pitches less than 2:12.
6.5.3 Non -Tile Applications Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by Y<-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the black selvedge edge to the deck with corrosion resistant roofing nails, nails &tin -tags or 1-inch diameter
plastic or steel cap nails spaced maximum 24-inch o.c. for slopes below 7:12 and maximum 12-inch o.c. for slopes
7:12 and greater. Overlap successive courses the entire width of the black -selvedge area, minimum 3-inch.
Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam
method detailed in Boral Roofing published installation instructions.
NEMO ETC, LLC Evaluation Report M35710.12.10-R11
CerdPcote ofAvt#oon#32055 6" EDITION (2017) FBC NON-HVH2 EVALUATION FL14317-RIO
h
Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018
Page 6 of 8
SNEMOjetc.
6.5.4 Non -Tile Applications. to Base Sheet:
Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus -in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install Boral TileSeal SO"r in accordance over ASTM D226, Type li felt or Citadel Plus with Boral Roofing published
installation instructions and Section 6.5.3, except end (vertical) laps, described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the fabric top surface, rolling the interface into place with a weighted roller.
6.6 GatorSeal
6.6.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof coveringto be installed.
6.6.2 Do not use GatorSeal on roof pitches less than 2:12.
6.6.3 Non -Tile applications. Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by X-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the black selvedge edge to the deckwith corrosion resistant roofing nails, nails & tin -tags or 1-inch diameter
plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and greater.
Overlap successive courses the entire width of the black -selvedge area, minimum 3-inch.
Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self -adhering
bituminous underside is in contact with the granular or mineral top surface, rolling the interface into place with a
weighted roller, or using the Inverted Sheet Seam detailed in Boral Roofing published installation instructions.
6.6.4 Non -Tile Applications, to Base Sheet:
Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install GatorSeal overASTM D226,Type II felt or Citadel Plus in accordance with Boral Roofing published installation
instructions and Section 6.6.3 except end (vertical) laps, described below.
Apply SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the granular top surface, rolling the interface into place with a weighted roller.
6.7 BoraLTileSeal"T or Boral MetalSeai"T:
6.7.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.7.2 Do not use Boral TileSealw or Boral MetalSeal"r on roof pitches less than 2:12.
6.7.3 Non -Tile Applications. Direct to Deck:
For OSB substrate, prime with ASTM D41 primer and allow to dry prior to installation. Cut the membrane into
manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by Y-inch.
Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the
exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller.
Fasten the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1-inch diameter plastic or steel
cap nails spaced maximum 12-inch o.c. Overlap successive courses the entire width of the black -selvedge area,
minimum 3-inch.
Seal under all end (vertical) laps using approved mastic or use Inverted Sheet Seam method detailed in Boral
Roofing published installation instructions.
NEMO ETC, LLC Evaluation Report W135710.22.10-R11
Certificate o)Authomavan A32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10
Boral Roof Underlayments; (602) 269-2289 Revision 11: 10/12/2018
Page 7 of 8
ONEW10letc.
6.7.4 Non -Tile Applications, to Base Sheet:
Install-ASTM D226, Type II felt_in.accordance with Code requirementsorinstall-Citadel Plus inaccordancewith
Boral Roofing published installation instructions and Section 6.4.
Install Boral TileSeal"T or Boral MetalSeal"T over ASTM D226, Type II felt or Citadel Plus in accordance with Boral
Roofing published installation instructions and Section 6.7.3, except end (vertical) laps, described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the fabric top surface, rolling the interface into place with a weighted roller. .
6.7.5 Tile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s),
Base Sheet fastening shall be not less than FRSA/TRl April 2012 (04-12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.4 herein.
Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf.
Refer to Section 5.8 for tile staging limitations. Battens must be used for all tile installations atop Boral TileSeal"r
or Boral MetalSeal"r with roof pitches of 2% to less than 3:12. Boral Roofing's Elevated Batten System or counter
battens are required.
As required bythe Building Official or Authority Having Jurisdiction in order to
this product.
NH
UL, LLC. — QUA9625; (631) 546-2458;
- END OF EVALUATION REPORT -
installation of
NEMO ETC, LLC Evaluation Report M35710.12.10-R31
Certificate ofAutAorizaoan A32455 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10
Boml Roof Undedayments; (602) 269-2288 Revision 11: 10/12/2018
Page 8 of 9
EXTERIOR RESEARCH & DESIGN, LLC.
Certifcate of Authorization 99503
353 CHRISTIAN STREET, UNIT #13
T rt ROPA1HII `)J^ ERD
OXFORD, CT 06478
PHONE:-(203)-262-9245-
FAX: (203) 262-9243
EVALUATION REPORT
Evaluation Report E10240.Og.Og-R4
East Coast Metals, Inc.
FL5374-114
2301 West 8 Lane
Date of Issuance: 09/03/2008
Hialeah, FL33010
Revision 4: D3/17/2015
SCOPE:
This Evaluation Report is issued under Rule GIG20-3 and the applicable rules and regulations governing the use Of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential volume. The products
d hSCANNED
herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted BY
DESCRIPTION: East Coast Metals Channel Metals St. Lucie County
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED coMpuANcE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify ea Robert ie complete rev ew a prod duct
changes or the
referenced Quality Assurance documentation changes. Trinity)ERD re
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityiERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection atthe job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. s9266, Florida OCA ANE3993
TAa l57' sealappeat...... uthamed tN Robert Nia.m.n,
P.E ant➢n,, .15. Thu dam not serve as an efeamNr+RYsigned
doWMVL
IDthcnametl mm.iteedtotha
CERTIFICATION OF INDEPENDENCE:
ire or will it acquire, a financial interest in any company manufacturing o
1. Trinityl ERD does not have, nor does it intend to acqu
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or Controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
a financial interest in any other entity involved in the approval process o e
4. Robert Nieminen, P.E. does not have, nor will acquire,
Product . ERD nor Robert Nieminen, P.E are, in any way, the Designer of Record for any
5. This is z building code evaluation. Neither Trinity)
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
� 4 1
L g :. 7 E La'tr—
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roofing Accessories that are an Integral Part of the Roofing System
Compliance Statement East Coast Metals Channel Metals, as produced by East Coast Metals, have demonstrated compliance
with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance
is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Pra a
Standard
Year
1507.3.7
Installation, non-HVHZ
FRSA/TRI April 2012 (04-12)
2012
1518.8.1
Installation, HVHZ
RAS 118, 119 & 120
1995
1523.65.2.2
Static Uplift Resistance
TA5101
1995
1711.2.1
Static Uplift Resistance
SBCCI SSTD 11
1997
3. REFERENCES:
Enti
Examination
Reference
Date
ERD(TST6049)
Static Uplift Resistance
E42730.08.13
08/23/2013
ERD(TST6049)
Static Uplift Resistance
ECO-SC6795.1Z14-1
02/27/2015
ERD(TST6049)
Static Uplift Resistance
ECNI-SC6795.12.14.2
02/27/2015
Florida TEC (TST7393)
TAS 301
530-628R
20/27/2010
PRI (TST5878)
TA5101
ECM-001-02-02
09/23/2001
PRI(TST5878)
TAS101
ECM-003-02-01
06/13/2008
PRI(TST5878)
TAS101
EQd-004-02-01
06/13/2008
PRI (TST5878)
TAS 101
ECIA-005-02-01
06/13/2008
PRI (TST5878)
TA5101
ECM-006-02-01
06/13/2008
PRI(TST5878)
TAS101
ECM-007-02-01
06/13/2008
PRI (TSTSB78)
TAS 101
ECM-OOM2-01
06/13/2008
Florida Building Code
Attachment Requirements
FRSA/TRI April 2012104-12)
0412012
Florida Building Code -HVHZ
Attachment Requirements
RAS 118,119 and 120
1995
East Coast Metals
Metal Quality
MIR Certifications
Various
Architectural Testing (QUA1844)
Quality Control
Participation Letter
Exp.12/31/2018
4. PRODUCT DESCRIPTION:
4.1 Hip & Ridge Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive.
Hip & Ridge Channel Metal is available in 119-3/8-inch (±
3/8-inch) length by 25, 3, 3.5, 4, 5, 6 or 7-inch L 3/8-inch)
heights with 1.5-inch (_1/16-inch) deck -flanges.
-Exterior Research and Design, U.C. Evaluation Report E10240.0E.08-R4
cereiFmte QFAvd erimtrae d9SW FL5374-R4
Revision 4: 03/17/2015
Page 2 of 7
RBN-PLf ERA
42 Trim Lock- Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive.
Trim Lock Channel Metal is available in 119-3/8-inch (±
3/8") length by 3, 3.5, 4, 5 or 6-inch (± 3/8-inch) heights
with 1.5-inch (} 1/16-inch) deck -flanges.
G�
4.2 Trim Lock Plus Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Plus Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive
and its perforated deck flanges, designed for installation
atop the roof underlayment via placement in FBC
Approved roof tile adhesive, which flows -through and
interlocks with the underlying adhesive.
Trim Lock Plus Channel Metal is available in 119-3/8-inch
(±3/8") length by 3, 3.5, 4, 5 or 6-inch (±3/8-inch) heights
with 1.5-inch I±1/16-inch) deck -flanges.
4.4 East Coast Metals Channel Metals are fabricated of the following metals:
D Galvanized Steel: Min. 0.019±0.002-inch, ASTM A653 (G-90), min. 33 K51.
Galvalume Steel: an. 0.019±0.002-inch, ASTM A792, A755, min. 35 KSI.
D Aluminum: Min. 0.032 ± 0.002-inch, ASTM B209, 3003-1-134, min. 21 K51.
D Stainless Steel: Miq. 0.019 ± o.o02-inch, ASTM A240/A480, T304, min. 35 K51.
5. LIMITATIONS: the Designer of
5.1 This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any '�Y. g
Record for any project on which this Evaluation Report, or previous versions thereof, is/eras used for permitting or
design guidance unless retained specifically for that purpose.
Evaluation Report E10240.08.08-R4
Exterior Research and Design, I.I.C. FL5374-R4
r-enifimie OfAuthoruatlan 89503 Revision 4: 03/17/2015
Page 3 of 7
Tell [RD
5.2 FOR HVHZJURISDICTIONS:
5.2.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119,
Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. For Trim Lock Plus Channel Metal, refer to the installation
instructions herein.
5.2.2 For HVHZ jurisdictions, installations of Hip & Ridge Channel Metal and Trim Lock are prescriptive by RAS 118, 119 and
120, and the data In Tables 1A and 1B is supplemental to these prescriptive allowances.
Installations of Trim Lock Plus are limited to projects having a required moment resistance (Mr) or uplift resistance (F,),
as determined In accordance with RAS 127, not greater than the followingvalues.
Referto the tile adhesive manufacturers published installation Instructions for adhesive paddy placement details.
D "INDEPENDENT' paddy placement means each individual tile is bonded to the Channel Metal in its own, single
foam paddy; tile head laps are not bonded. This method is limited to 2-part tile adhesives. Allowable
performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to
ultimate performance.
D "INTERDEPENDENT" paddy placement means each individual file is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap, or two tiles are, bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
_ TAatE1A: PERFORMANCE LIMRATONs- HVHZ, INDEPENDENT PADDY PLACEMEUT
(2 To 1 WRGM OFSAF1rVAWMDYAPPOED)
Hip/Ridge
Metal
Tile
Adhesive
Allowable Performance
Design
Metal Type
type
Placement
Moment Based
Uplift Based
Mr(ft-lbf)
F'(Ibf)
Hip &Ridge
galvanized
day or
3M"'2-Component Foam
/ndepehdent
127
169
Channel Metal
concrete
Roof Tile Adhesive AH-150
Trim lurk
galvanized, Galvalume",
day or
3M^'2-Component Foam
Independent
171
159
aluminum orstainless steel
concrete
Roof Tile Adhesive AH-160
Trim Lock Plus
galvanized, Galvalumee,
day or
310-2-Componem Foam
Independent
177
1fi5
aluminum or stainless steel
concrete
Roof Tile Adhesive AH-160
_ TABLE IB: PERFORMANcE LLMITATIONs-HVHZ, INTERDEPENDENT PADDY PLACEMENT
(4 To IA GLN aFSAFPTYALREADYAPPLiw)
Hip/Ridge Metal
Tile
Adhesive
Allowable Performance
Moment Based
Uplift Based
Design
Metal Type
Type
Placement
Mr(ft-lbf)
V(Ibf)
Trim Lock or Trim
galvanized, 1331valumee,
day or
310-2-Component Foam
Interdependent
95
88
Lock Pius
aluminum or stainless steel
concrete
Roof Tile Adhesive AH-160
Trim Lock
galvanized, Galvalumeo,
clay or
3M"' Roof Tile Adhesive
Interdependent
99
94
stainless steel
concrete
RTA-1
Trim Lock
aluminum
day or
310-Foam Roof Tile
Interdependent
90
84
concrete
1 Adhesive RTA-1
Trim Lock Plus
galvanized, Galvalumea,
day or
3W Foam Roof Tile
Interdependent
90
84
aluminum arstainiess steel
concrete
Adhesive RTA-1
Trim Lock
galvanized, Galwlume or
clay or
TILE BOND'" Roof Tile
Interdependent
123
117
stainless steel
concrete
Adhesive
Trim Lock
aluminum
day or
TILE BOND"' Roof Tile
interdependent
79
73
concrete
Adhesive
Trim Lock Plus
galvanized, Galvafumes,
day or
TILE BOND'" Roof Tile
interdependent
79
73
aluminum orstainless steel
concrete
Adhesive
Trim Lock
galvanized, Galvalume"or
day or
Touch'n Seal StormBond
Interdependent
146
139
stainless steel
concrete
Roof Tile Adhesive
Trim Lock
Aluminum
day or
Touch'n Seal StormBond
Interdependent
58
54
concrete
Roof Tile Adhesive
Trim Lock Pius
galvanized, Galvaiumeo,
day or
Touch'n seal StonnBond
Interdependent
58
54
aluminum or stainless steel
concrete
Roof Tile Adhesive
Exterior Research and Design, U.C. Evaluation Report E10240.08.08-114
Cerdpmte ofAuthomadon C9SD3 . FL5374-R4
Revision 4:03/17/2015
Page 4 of 7
RINM,° ERD
5.3 FOR NON-HVHZJURISDICnONS:
5.3.1 For Hip & Ridge Channel Metal or Trim Lack Channel Metal, refer to FRSA/TRI April 2012 (04-12). For Trim Lock Plus
Channel Metal, refer to the installation instructions herein
5.3.2 For non-HVHZ, installations are limited to projects having hip and ridge design pressure requirements, determined in
accordance with Table 3A'of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the tile
adhesive manufacturer's published installation instructions for adhesive paddy placement details.
`r "INDEPENDENT" paddy placement means each individual file is banded to the Channel Metal in its own, single
foam paddy, tile head laps are not bonded. This method is limited to 2-part tile adhesives. This method is limited
to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2
to 1 margin of safety applied to ultimate performance.
D "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the file head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
TABLE2A: PERFORMANCELLMITATIONs—NON-HVHZ,INDEPENDENTPADDYPLACEMENT
(2TOI MARGINOFSAFETYALRFAOYAPPUEO)
Hip/Ridge Metal
Title
Adhesive
Allowable Uplift
(Psf)
Design
Metal Type
.fie
Placement
Hip & Ridge
galvanized
day or
3M'" 2-Component Foam Roof
Independent
p
169
Channel Metal
concrete
Tile Adhesive AH-160
Trim Lock
galvanized, Galvalumee, aluminum or
clay or
3M"' 2-Component Foam Roof
Independent
173
stainlesssteel
concrete
Tile Adhesive AH-160
Trim Lock Plus
galvanized, Galvalume°, aluminum or
day or
3M"' 2-Component Foam Roof
Independent
178
stainlesssteel
concrete
Tile Adhesive AH-160
IABLE23: PERFORMANCE ILMITIrnONs—NON-HVHZ, INTERDEPENDENT PADDY PLACEMENT
(4TO 1WRG/NOFSAFFLYALRFADYAPPNtD) "
Hip/Ridge Metal
Tile
Adhesive
Allowable Uplift
(Psf)
Design
Metal Type
Type
Placement
Trim Lock or Trim
galvanized, Galvalume", aluminum or
day or
3M'" 2-Component Foam Roof
Interdependent
98
Lock Plus
stainless steel
concrete
Tile AdhesiveAH-160
galvanized, Galvalume orstainless
clay or
3M'" Foam Roof Tile Adhesive
Interdependent
110
Trim Lock
steel
concrete
RTA-1
day or
3M"' Foam Roof Tile Adhesive
Interdependent
93
Trim lock
aluminum
concrete
RTA-1
galvanized, Galvalume, aluminum or
day or
3M'" Foam Rool"M eAdhesive
Interdependent
p
93
Trim Lock Plus
stainless steel
concrete
RTA-1
Trim Lock
galvanized, Galvalume° orstainless
clay or
TILE BOND— Roof Tile Adhesive
Interdependent
152
steel
concrete
Trim Lock
aluminum
clay or
TILE BOND— RoofTde Adhesive
interdependent
82
concrete
Trim Lock Plus
galvanized, Galvalume', aluminum or
clay or
TILE BOND'" Roof Tile Adhesive
Interdependent
82
stainless steel
concrete
galvanized, Galvalume' orstainless
day or
Touch'n Seal StormHond Roof
Interdependent
148
Trim Lock
steel
concrete
Tile Adhesive
day or
Touch'n Seal StormBond Roof
Interdependent
61
Trim lock
Aluminum
concrete
Tiie Adhesive
galvanized, Galvalume°, aluminum or
clay Or
Touch'n Seal Stormoond Roof
Interdependent
61
Trim Lock Plus
stainless steel
concrete
Tile Adhesive
Exterior Research and Design, LLG Evaluation Report E10240.08.08-R4
CzMTmre O7AurADdredan R9sM FLS374-114
Revision 4: 03/17/2015
Page 5 of 7
TRWITY ERD
6. INSTALLATION:
6.1 The roof deck shall be minimum 15/32-inch plywood (non-HVHZ) or minimum 19/32-inch plywood (HVHZ) attached in
accordance with FBC Chapter 23 to the satisfaction of the AHJ.
6.2 Hip & Ridge Channel Metal and Trim Lock Channel Metal shall be installed using min. 11 ga. x 1Y,-inch long x 3/8-inch
head diameter galvanized annular ring shank nails spaced 6-inch o.c. along both deck -flanges. Fasteners shall be
positioned Y-inch from the outside edge of each deck -flange, set in a bed plastic roof cement. For FBC HVHZ, refer to
FBC RAS 218, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3.
6.3 Trim Lack Plus Channel Metal shall be installed atop the Approved roof underiayment in continuous 2-inch wide ribbons
of tile adhesive centered beneath each 1.5-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet
adhesive and allow it to set-up prior to installation of roof tiles.
View of Polyset AH160 Placementfor Trim Lock Plus Channel Metal Installation
63.1 It is critical that the bond between the Trim Lock Plus Channel Metal, the tile adhesive and the underiayment is not
disturbed prior to or during placement of the ridge tiles.
6.3.2 Approved underlayments are the codified '30/90' system or other FBC Approved roof underlayments listing approved
use of the subject file adhesive.
Eaerler Research and Design, r Evaluation Report e10240.08.08-R4
FL5374 4
Certlflcore ofAurhariza8an #9503
Revision 4: 03/17/2015
Page 6 of 7
WNW �f ERE)
6.4 Tile shall be installed. atop. the Channel Metal in accordance with the tile. adhesive. manufacturer's Approved, published
installation instructions, subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and
pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (04-12) or RAS
116, RA5119, RA512O requirements.
Hip / Ridge Tile
Tile Adhesive
Trim Lock Plus
Mortar or Weather Block
Adhesive
Tile Adhesive
View of Trim Lock Plus Channel Metal installation after Weather Blocked
6.4.1 Channel Metal shall be free of dust, debris, oils or other bond -breaking substance prior to placement of adhesive.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
R. MANUFACTURING PLANTS:
Contact the named CIA entity for manufacturing facilities covered by FA.0 Rule 61G20-3 QA requirements.
9. QUAUTYAssURANCE ENTITY:
Architectural Testing, Inc — QUA1844� (717) 764-7700
- END OF EVALUATION REPORT -