Loading...
HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSENGINEERING & TESTING, INC. Phone: (866) 781-6889 *Fax- (866) 784-8550 rrr- .floridaengineeringandtesting.com 250 S.W.13'h Avenue Pompano Beach, FL 33069 DATE: 2/19/19 JOB ORDER #: 19-875 CLIENT: Trade Winds Roofing, Inc. ADDRESS: PO Box 13208 Fort Pierce, FL 34979 PROJECT: Shawn Deggins Residence Flat Wood Non -Insulated Roof Deck ADDRESS: 2707 North AIA - Ant. H Fort Pierce, Florida SCANNED 2017 FBC/ASCE-7 DESIGN PRESSURE CALCULATIONS BY St. Lucie County Proiect Information: Height = 12' Exposure: D Basic/Ultimate Wind Speed: V"e=170 mph Length = 16' Category: H Nominal Wind Speed: V.d=V it*40.6 Width = 10' Slope: < 7° (asd = allowable strength design) Parapet Wall: N/A Residential Kz = 1.03, Kzt = 1.0, Kd = 0.85 Design Calculations: Velocity Pressure: q = 0.00256*KXztKdV2 Velocity Pressure (u): q=0.00256(1.03)(1.0)(0.85)(170)2 = 64.77 psf Velocity Pressure (.d): q=0.00256(1.03)(1.0)(0.85)(170*40.6)2 = 38.86 psf Width of Pressure Coefficient: 0.1(10') = 1.0' 0.4(12') = 4.8' ) use: 3'0" Effective Wind Area: <10ft2 For parapet height three feet (3') or larger, zone three (3) shall be treated as zone two (2). External Pressure Coefficient: 1) GCP1 = -1.0 2) GCP2 = -1.8 3) GCP3 = -2.8 Internal Pressure Coefficient: 1) GCP; = 0.18 '1, v�Q v Quality ��3A�i?.3ssarance Page 2, 2/19/19, Job Order ?Fiy-875 Trade Winds Roofing, Inc. FLO L� Shawn Deggins Residence Flat Wood Non Insulated Roof Deck 2707 North AIA - Apt. H; Fort Pierce, FL: -- -- - DesienPressures Based on Vasd: 1) Field P1 = 38.86*[(-1.0) — (0.18)] = -45.9 psf 2) Perimeter P2 = 38.86*[(-1.8) — (0.18)] = -77.0 psf 3) Corners P3 = 3 8.86* [(-2.8) — (0.18)] = -115.8 psf Attachment Requirements Per RAS-117: Based on the requirements of Florida Product Approval # FL1046-R8, Appendix 1, pg 6 of 22, System No. W-11, with a maximum design pressure of-52.5psf; the following are our recommended fastening patterns to attach the proposed two plies of PermaPly 28 or Ventsulation base sheet to the min. 19/32" plywood deck utilizing approved 32 ga., 1- 5/8" diameter tin caps with 11 ga. annular ring shank nails: Field: 9" o.c. @ 4" laps and 2 staggered rows 12" o.c. Perimeter: 9" o.c. @ 4" laps and 3 staggered rows 9" o.c. Corners: 9" o.c. @ 4" laps and 5 staggered rows 9" o.c. *Note: If any portion of the anchor/base sheet falls within the perimeter or corner zones, then the entire sheet has to be fastened to the requirements of that zone. Notes: Corners and perimeter area dimension shall not be less than a = 3'0" Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2017 Edition. Wind load calculations based on ASCE-7, 2017 FBC and information provided by client. Client is responsible for verifying existing/proposed conditions/decks as it pertains to the above provided product approval. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. Mark A. Mesiano,�P. STATE OF 4� Florida Engineeriri $t' � Z Florida Reg. No. 482�¢y Ss� ---- g�G`�� Certificate of Authorize&dx"09- 3i��x