HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online
Page I of 2
i r 1����.rh.,t"'v
)..,..2
SCISHome ;lapin ;User Resistrabon Hoc Topic
i Product Approval
USER: Public user
t
Submit Surcharge Suits, &Facts Publications - F CSMII MS SIM Map links Search
EroLocLAOD ArsiiM4nu > PrdµcLit, A�plicadon Search > AWkapon lisp > Application 0ecniI
i.�
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
FL1046-RB
Revision
2017
Approved
Johns Manville
P.O. Box 5108
Denver, CO 80217
(303) 978-4879
codes@Jm.cam
Chris McBride
codes@Jm.cem
Roofing
Modified Bitumen Roof System
SCANNED
BY
St. Lucie County
Evaluation Report from a Florida Registered Architect are Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received -
Robert Nleminen
PE-59166
UL LLC
06/23/2019
John W. Knezevich, PE
J, Validation Checklist - Hardcopy Received
FL1046 R8 COI 2017 01 COI Nientinen.odf
Referenced Standard and Year (of Standard) Standard
year
ASTM D6164
2011
ASTM D6222
2011
ASTM D6223
2011
ASTM D6509
2009
FM 4470
2012
Equivalence or Product Standards
Certified By
Sections from the Code
http://1vww.floridabuilding.orglpr/pr_app_dtl.aspx?param=wGEVXQwtDqudsDrIH6I48%... 1/15/2018
Florida Building Code Online
Page 2 of 2
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
I 1
Method 1 Option D
10/16/2017
10/172017
10/17/2017
12/12/2017
FL #
Model, Number or Name
Description
1046.1
Johns Manville APP Modified
APP Modified Bitumen Roof Systems
Bitumen Roof Systems
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL1046 R8 II 2017 10 FINAL Al ER 1M MODBIT APP FL1046-
Modf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-315
Created by Independent Third Pally: Yes
Other: 1.) The design pressure noted herein pertains
Evaluation Reports
to one specific assembly within the ER. Refer to the
FL1046 R8 AE 2017 10 FINAL ER ]M MODBrr APP FL1046-
Re.pdf
ER Appendix for all systems and design pressure
limitations. 2.) Refer to ER Section 5 for limits of Use.
Created by Independent Third Party: Yes
Back Next
contact :: 2601 Blair Stone Road. Tallahassee R 32399 Phone: 850 4W-IB24
The State of Florida Is an AAXEO employer. Ccovdaht 2007-2013 State of Florida.:: Privacy Statement:: Accesslbiliy Statement :: Refund Statemen
Idler Florida mv, small addresses are public records. if you do not want your ¢-mall address released in resyonse to a public -records re,n st, do not Sena
:ironic mall M Nis entity. instead, contact Me office by phone or by traditional mall. If you have any quaybons, please contact 850.487.1395. 'Pursuant n
an 455.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under nether 455, FZ. must provide Me Department win an email address if
y have one. The emalk provided may be used for official communlmdo0 with Me licensee. However email addresses are public record. If you do not wish to
a personal addme , please provide Me Department win an email address which can be made available n no public. To determine if you are a licensee under
CTapter 455, F.S., please M& here .
Product Approval Acimme:
ooP_�;qtl-o
Credit Card
Safe
http://www.floridabuilding.orglnrlpr_app_dtl.aspx?param=wGE VXQwtDqudsDrIH6I48%... 1 / 15/2018
TRINs-fl'
ERD
APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
Table Deck Application
Type Description
Page
IA-1
Wood New, Reroof (Tear -Off)
A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
4
1A-2
Wood New, Reroof (Tear -Off), Recover
A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
4
1B
Wood New, Reroof (Tear -Off), Recover
B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
4
1C
Wood New, Reroof (Tear -Off), Recover
C Mech. Attached Insulation, Bonded Roof Cover
5
1D
Wood New, Reroof (Tear -Off), Recover
D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
5
'�fETW Wood New, Reroof (Tear -Off)
E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
6
lE-2
Wood New, Reroof (Tear -Off), Recover
E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
6
2A
Steel or Structural concrete New, Reroof (Tear -Off), Recover
B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
7-11
2B
Steel or Structural concrete New, Reroof (Tear -Off), Recover
C Mech. Attached Insulation, Bonded Roof Cover
12
2C
Steel or Structural concrete New, Reroof (Tear -Off), Recover
D Prelim. Attached Insulation, Mech, Attached Base Sheet, Bonded Roof Cover
13
3A
Structural concrete New, Reroof(Tear-Off)
A-1 Bonded Insulation, Bonded Roof Cover
1445
3B
Structural concrete New, Reroof (Tear -Off)
F Non -Insulated, Bonded Roof Cover
15
4A-1
LWIC New, Reroof (Tear -Off)
A-1 Bonded Insulation, Bonded Roof Cover
16
4A-2
LWIC New, Reroof (Tear -Off)
A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
17-18
4B
LWIC New, Reroof (Tear -Off)
E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
19
5A
CWF New, Reroof (Tear -Off), Recover
E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
20
6A
Gypsum Reroof (Tear -Off)
A-1 Bonded Insulation, Bonded Roof Cover
20
6B
Gypsum Reroof (Tear -Off)
E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
20
7
Various Recover
A-1 Bonded Insulation, Bonded Roof Cover
21-22
The followine notes apply to the systems outlined herein:
1.
The roof system evaluation herein pertains to above -deck roof components,
Roof decks shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Wind load resistance of
the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2.
Unless otherwise noted, fasteners and stress plates for insulation attachment
shall be as follows. Fasteners shall be of sufficient length for the following engagements:
i Wood Deck: Ultra Fast Fasteners or All Purpose Fasteners with
UltraFast Metal Plates. Minimum 0.75-Inch plywood penetration or minimum 1-inch wood plank embedment.
i Steel Deck: UItraFast Fasteners or All Purpose Fasteners with Ultra Fast Metal Plates. Minimum 0.75-inch steel penetration and engage the top flute of the steel deck.
i Structural concrete: All Purpose Fasteners with Ultra Fast Metal Plates or Struct conc. Fasteners with UllraFast Metal Plates (flat bottom only). Minimum 1-Inch embedment. Fasteners
Installed with a pilot
hole in accordance with the fastener manufacturer's
published installation Instructions.
3.
Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board, Invinsa Roof Board or Invinsa
oam that meets the CIA
requirements of F.A.C. Rule 61620-3 and is documented as meeting FBC 1505.1
and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
4.
Minimum 200 psi, minimum 2-Inch thick lightweight insulating concrete may
be substituted for, or installed below the rigid insulation board for System Type D (mechanically attached base sheet,
bonded roof cover),
whereby the base, sheet fasteners are Installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel a
�d concrete deck listings.
Roof decks and structural members shall be in accordance with FBC requirements
to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented
through proper codified
and/or FRC Approval documentation.
5.
Preliminary Insulation attachment for System Type D: Refer to Section 2.2.10.1.3
of FM Loss Prevention Data Sheet 1-29 (January 2016).
Exterior
Research and Design, I.I.C. d/b/a Trinity IERD
Evaluation Report 19340
07.08-RS for FL1046-RB
Certificate ofAuthorization #9503
6v" EDITION (2017) FBC NON.HVHZ EVALUATION
I Revision 5: 10/14/2017
Prepared by: Robert Nidminen, PE-59166 Johns Manville APP Modified Bitumen Roof Systems; (330) 978-4e79
Appendix 1, Page 1 of 21
INITY'ERD
6. Unless otherwise,noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions.
S Hot asphalt (HA): Full coverage at 25-30lbs/square
JM MBR Bonding Adhesive (MBR-BA): Continuous 0.75-inch wide ribbons, 12-Inch o.c. or full coverage at 2.0 gal/square
i JM Two -Part Urethane Insulation Adhesive (UTA-TWO-PART): Continuous 0.75-inch wide ribbons, 12-inch o.c. Note: JM Green Two -Part Urethane Insulation Adhesive maybe used where VIA-TW6PART is
referenced.
➢ JM Roofing System Urethane Adhesive (RSUA): Continuous 0.5 to 0.75-inch wide ribbons, 12-inch o.c.
i 3M CR-20: Continuous 2.5 to 3.5-inch ribbons, 12-inch o.c.
9 Note: When multiple loyers(s) of insulation and/or coverboord are installed in ribbon-applledadhesive, adhesive ribbons shall be staggeredfrom layer -to -layer a distance ofone-halffhe ribbon spacing.
J% Note: The maximum edge distance from the adhesive ribbon to the edge of the Insulation board shall be not less than one-half the specified ribbons spacing.
7. Unless otherwise rooted, all insulations are Rat stock or taper board of the minimum thickness noted. Tapered polylsocyanurate at the following thickness limitations maybe substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular s tern In the tables, then
the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table:
➢ JM Two -Part Urethane Insulation Adhesive(UTA-TWO-PART): MDP -315.0 psf (Min. 0.5-Inch thick)
➢ JM Roofing System Urethane Adhesive (RSUA): MDP -157.5 psf (Min. 0.5-inch thick)
i 3M CR-20: MDP -117.5 psf (Min. 1.0-inch thick)
8. Bonded polylsocyanurate Insulation boards shall be maximum 4 x 4 ft.
9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDI, FM Loss
Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk• carry the limitations set forth in Section 2.2.10.1 of FM Loss
Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
10. For assemblies where all components are fully adhered, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no
rational analysis is permitted.
11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the dati for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TA5 105.
12, For existing substrates in a bonded recover or re -roof Installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift tel}ling in accordance with
_ ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13. For Recover Applications using System Type D, the insulation Is optional. Alternatively, an FBC Approved coverboard may be used as a separator board, preliminarily attached prior to roof cover installation. The
existing roof system shall be suitable for a recover application.
14. Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referent
Product Approval 'for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC Is not referenced, the minimum design mix shall be 300 psi. In all
coat thickness is 2-Inches. For LWIC overstrUctural concrete, reference is made to FBC Section 1917.4.1, Point 1.
Exterior Research and Resign, I.I.C. d/b/a Trinity HERD
Certificate of Authorization #9503 Gm EDITION (2017) FBC NON-HVHZ EVALUATION
Prepared by: Robert Nieminen, PE-59166 Johns Manville APP Modified Bitumen Roof Systems; (330) 978-4879
refer to current LWIC
es, the minimum top -
for FL1046-RS
5: 10/14/2017
1, Page 2 of 22
Z4)
INITY , ERD
TABLEIE•1: WOOD DECKS- NEW CONSTRUCTION ORREROOF(TEAR•OFF) ,
i
I SYSTEM *PEE: NON -INSULATED, MECHANICALLY ATTACHED, BASE SHEET, BONDED ROOF COVER
System
Deck
Base Sheet
Roof Cover
Note 15)
Nm.
(Note 1)',
Sli Sheet
p
MDP (psf)
Base
Fasteners
Attach
Ply
Cap
fMin. 19/32.
(Optional) One or more layers
Two plies of PermaPly
32 ga., 1-5/8-Inch diameter tin caps
9-inch o.c. in 4-inch lap and 12-Inch o.c. in
(Optional)
APP-TA
-52.5
`11
inch plywood
PermaPly 28, loose laid below
28 or Ventsulation
with 11 ga. annular ring shank nails
two, equally spaced, staggered center rows
APP-TA
TABLE lE-2: WOOD DECKS— NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER
SYSTEM TYPE E:NON-INSULATED, MECHANICALLY ATTACHEDBASE SHEET, BONDED ROOF COVER
System
Deck
Base Sheet
Roof Cover
(Note 15)
(Note Note 1)
Slip Sheet
MDP (psf)
Base
FastenersAttach
Ply
Cap
W 12
Min. 19/32-.
(Optional) One or more layers
JM APP Base, PermaPly 28,
Note 2
12-inch o.c. in 4-inch lap and 18-Inch o.c. in
(Optional)
APP TA
A5 0•
Inch plywood
PermaPly 28, loose laid below
Glasbase Plus or Ventsulation
two, equally spaced, staggered center rows
APP-TA
W-13
Min. 15/32-.
(Optional) One or more layers
DynaFast 180 HW or
High Load Fasteners and APB
18-Inch o.c. within the min. min. 4-inch wide,
(Optional)
APP TA
45.0•
inch
PermaPly 28, loose laid
DynaFast 250 HW
Plates or High Load Plates
heat -welded side laps.
APP-TA
W 14
Min. 19/32-
(Optional) One or more layers
Two plies of PermaPly 28 or
Note 2
9-Inch o.c. in 4-inch lap and 12-inch o.c. In
(Optional)
APP-TA
-52.5
inch plywood
PermaPly 28, loose laid below
Ventsulation
two, equally spaced, staggered center rows
APP-TA
Exterior Research and Design, LLC, d/b/a Trinity l ERD Evaluation Report J9340107.08-RS for FL3046-RB
Certificate of Authorization N9503 6" EDITION (2017) FBC NON-HVHZ EVALUATION I Revision 5: 10/14/2017
Prepared by: Robert Nieminen, PE-59166 Johns Manville APP Modified Bitumen Roof Systems; (330) 978-4879 Appendix 1, Page 6 of 22