HomeMy WebLinkAboutLOAD CALCULATIONOptional Load Calculation
Heat Larger Than Air
j SF x 3VA Living Only
(2) Small appliance ckts @ 1500VA each
Refrigerator @ 1500
Refrigerator @ 1500
Freezer @ 1500
Washing Machine @ 1500
Dishwasher @ 1500
Disposal @ 1500
Mini Sewer @ 1S00
Clothes Dryer @ 5000
Range @ 12000
Water heater @ 4500
Fixed microwave @ 1500
Vacuum @ 1500
Trash Compactor @ 1500
Pool Heater @ 'name plate'
Spa @ 'name plate' 1
Motors 746VA per HP l.a 2 1 V 5
Garage Door Opener
9,V
1) Total
2) First 10 KVA of general load @ 100%
3) Subtract line 2 from 1
4) Multiply line 3 @ 40%
5) Add lines 2 and 4
6) 60/50amp breaker for heat (10000)
7) 40/30amp breaker for heat (5000)
B) Total heat- Add lines 6 and 7
9) Multiply line 8 @ 65%
10) Add lines 5 and 9
11) Divide line 10 by 240
Summary:
Line 101sthe total KW
Line 11 is the total Amps -
SCANNED
BY
St. Lucie County
- /o006
N3s7-Cc
16600
— /DOOb
- Cn5D0
=_r2699_7,C9 (Generator Size Needed)
9% r 0 3 (Breaker Size Needed)
z � j