HomeMy WebLinkAboutPOOL PLANSFILE COPY VS-FHP1.0 PERFORMANCE CURVES F 90 I O t N LU U. 60 3450 RPM Q 50 LU S 40 U_ i 30 2750 RPM IOSORPM Z } Q 21 1730 RPM J 10 H ' 0 H 0 10 20 3D 40 50 60 70 00 90 100 110 120 130 140 ISO 160 1" 180 190 2W FLOW GPM ELECTRICAL DIAGRAM AND ELECTRICAL DIAGRAM N.T.S. GFI OUTLET PER 2014_NEC POOLBOND PB-2008 WATER HEAT PUMP WITH JANDY TRUE (3) #6 CU & (1) #10 CLEAR SALT MANUAL MOTOR STARTER CU GROUND IN 1" SWITCH CONDUIT 1HP VARIABLE SPEED JANDY PUMP MOTOR WITH BUILT-IN POOL PANEL W/ 80 AMP OVERLOAD SWITCH W/3- #10 THHN BRKR & (2)-#4 & (2) #10 GND CU WITHIN %" MIN. CONDUIT (GFCI THHN CU IN 1" RPVC CONDUIT PROTECTED) S.P.S.T. TOGGLE SWITCH (2) POOL LIGHTS (GFI NOT REQUIRED JUNCTION BOX I TIME CLOCK PUMP 1 PUMP W. P. DISCONNECT BONDED BACK TO 12 VOLT TRANSFORMER POOL DECK P1 UL LOCATION OF WATER BOND 1. ALL ELECTRICAL TO COMPLY WITH 2O14 NATIONAL ELECTRIC CODE. ELECTRICAL CONTRACTOR TO VERIFY ADEQUATE CAPACITY AT POINT OF CONNECTION 2.3412 THHN CU WITHIN %" MIN. CONDUIT FOR POOL LIGHT(S) 3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC. IA//#8 SOLID, BARE COPPER. 4. PROVIDE W.P.G.F.I. OUTLET 10' MIN. -20' MAX. FROM WATER'S EDGE. 5. ALL POOL PUMPS TO BE GFCI PROTECTED PER NEC 680.22(B) PIPING SCHEMATIC EQUIPMENT LAYOUT N.T.S. 1.5" VACUUM LINE 2.5" POOL MAIN DRAIN 2" SKIMMER LINE 2" POOL RETURN LINE TO FIRST TEE, 1.5" TO POOL JANDY TRUE CLEAR SALT SYSTEM 1.5" TO WASTE OR DISCHARGE TO GROUND 1HP JANDY VARIABLE FHPM PUMP WITH W/APPR HAIR AND LINT STRAINER CARTRIDGE FILTER W/ PRESSURE GAUGE AND AIR RELIEF VALVE INSTALL PERMA-CAST WATER BOND OR APPROVED EQUAL TIED TO PUMP 20UND W/ #8 SOLID COPPER & APPROVED LUG (MIN. 9 SQ. IN SURFACE AREA :POSED TO WATER) PER MFGR'S SPECS (FIELD VERIFY LOCATION) HEAT PUMP W/INTERNAL BY-PASS VALVES tllnerum/iedMadiullatle.VGB1000 6 18XXV ,•ne.onn f mwn.m. '� I ,�� wauwara gwnmm.la«a,wn�m., sxarv�a �I .+--.� rmmmwa:�n ¢nqu a 7a.d n.eaaa*e19e aaama".� Io,MrtpVl IASME 011119&Ynl>anal.5Mf P112198a]GI as06mi InlPKkl«e M`M�-ma [mlrrenMunen.,u®.I.soamna:mom q 3939EImpWI Y"^/fuYelfgByG9)Bl1dR9. f[ wmmraulluv.ae:a,a�memay..mau.,« LJ.I.m m P%Y ❑ Q DakGery O tlroa . o,emnYMIN. � m�.nrvmu/4�" wm4 .w�„9e. ®Iama.YwlOYWre9a .�YY.m.�ape......E.O.n..lwuv yayMt pyMpe Yn Le,10psPm 1louPae2rt WPPvu P PYM Sqo 6VN I w mr nn r +.a m _ nw F I m GPM r /dc�if lil 'I-.-;F.a I, laf�i�a al@a. �j%�te�rv�y x THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO C014PLY WITH ALL APPLICABLE CODES. CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OR RECORD FILE COPY POOL DETAIL - APPROVED CODE FOR RESIDENTTIALITH ATHEND THEO17 ANSIIAPSP-B20FLORIDAI06 FOR SUCTION ENTRAPMENT AVOIDANCE APPROVED MAIN DEATH FRAMES AND GRATES PER V.G.& ASME1 ANSI 112.19.8.207 MINIMUM (2) SUCTION LINES PER PUMP 3. FT. SEPARATION OR SEPARATE PLANES 3" SUCTION LINE MAX 181 G.P.M. TO FILTRATION PUMI' 2.5" LINE TO FIRST TP.E. 1.5" TO POOL 6 FPS MAX 18" MIN. ( ENTIRE PERIMETER) W.I- #8 SOLID COPPER BOND WIRE WI APPR. CLAMPS (ONE ON EACH SIDE OF POOL 4 - TOTAL) EQUIPOTENTIAL BONDING GRID DETAIL PER N.E.C. 2014 SEC. 680.26 (WHERE ADOPTED) MISC. NOTES 1. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2X6 CAPTILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY 2. HAND HOLD TO BEA.6" WHERE DECK RAISE ABOVE PO� i 48" MAX WATE DEPT T MAX N.T.S. PLUMBING LINES FROM SUMPWI3" TEE SOIL S GAUGE SOLID COPPER V49M MINIMUM 18" MAX 24" FROM EDGE OF POOL AROUND ENTIRE POOL PERIMETER BURIED 4" TO 6" DEEP 48GROUND F HANDRAIL BONGING WIRE DETAIL WHERE APPLICABLE PER NATIONAL STEPS ELECTRICAL CODE STEP DETAIL 1. TREAD IS MIN. OF 10" WIDE. 2. RISER NOT GREATER THAN 12" EXCEPT IF MORE THAN (3) TREADS ARE USED. 3. ALL STEPS TO BE SOLID GUNITE 4000 PSI. OUTSIDE ANGLE OF REPOSE 6' AND FURTHER =4" THICK WALLS WM3 REBAR @ 12" O.C. EACH WAY 3' TOW = V THICK WALLS WM13 REBAR @ 12" O.C. EACH WAY 0' TO 3-= 8" THICK WALLS WM3 REBAR @ 12" O.C. EACH WAY � m ; m 3ft i 0 0 i z P EXCAVATION INTO THE ANGLE OF REPOSE IS ALLOWABLE PROVIDED : `SHORING IS INSTALLED AT EXCAVATION AND SHORING SHOULD BE SUFFICIENT TO SECURE SOILS FROM EROSION OR SETTLEMENT NO UNDERMINING OCCURS OR ENGINEER APPROVED IF ANY DOES ' COMPACTION TEST OF THE BACKFILLED MARTIAL ARE PROVIDED AT C.O. OF THE SWIMMING POOL SCREEN ENCLOSURE THROUGH PIONEER BRONZE rSE PLANS AV" ""('L7 WORK i; SUBJECTT, 'AIS OJIRED BY F 'HAT NECEL _.."BE .'PLY WITH. . =,k . >. _.,,ODES. )' Y I � *LOCATION OF GFI I RECEPTACLE I I e TO BE DETERMINED IN FILE COPY EQ FIELD PER NEC 680 ov�RFLOw VERIFY II 1 a5" ( Q PAD EXACT 12'•-------i---- � PAD O PER FBC LOCATION IN I R4501.22 FIELD WITH I SUPERVISOR I I GENERAL NOTES: I I 1. SWIMMING POOL CONSTRUCTION TO COMPLY W/ FLA. BLDG. CODE AND WITH ALL LOCAL ORDINANCES AND ZONING REGULATIONS. 2. SWIMMING POOL TO BEAR ON ROCK OR UNDISTURBED STAND. ALL WALLS AND FLOORS SHALL BE GUNITED OR POURED IN -PLACE CONCRETE WI MINIMUM 3,000 P.S.I. CONCRETE (@ 28 DAYS) COMPRESSIVE STRENGTH. 3. ENGINEER SHALL BE NOTIFIED IF SOIL BEARING I ....... I... -........ LESS THAN 2500 P.S.F., OR MUCK, SILT OR LOOSE, 7 ft.p in. SOFT SOIL IS FOUND. A SOIL BEARING CAPACITY OF I 2,500 P.S.F. IS ASSUMED FOR THIS PROJECT. I I 4. REINFORCING BARS SHALL BE NEW BILLET, GRADE 40. I 5. ALL POOL PIPING TO BE P.V.C. SCHEDULE 40 MIN. AND I BEAR THE N.S.F. APPROVAL. ) 6. BACK -WASH SHALL BE IN COMPLIANCE WITH LOCAL ORDINANCES. 7. DISPOSAL OF POOL WATER SHALL CONFORM TO LOCAL ORDINANCES. SURFACE GRADING SHALL CONTAIN WATER WITHIN PROPERTY LINES. PONDING SHALL NOT PERSIST I I 7 FOR MORE THAN ONE HOUR. I i 8. WATER SUPPLY & DISPOSAL SHALL BE INSTALLED SO THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC I WATER SUPPLY OR WATER DISPOSAL SYSTEM. I 9. GRATE AT MAIN DRAIN SHALL HAVE A FREE AREA OF 4X THE AREA OF THE SUCTION LINE 1.5" THE 10. HAIR & LINT STRAINERS SHALL HAVE A REMOVABLE SCREEN W/ A MINIMUM FREE AREA OF 3X THE AREA OF THE SUCTION LINE. 11. ELECTRICAL: INSTALL WIRING & DEVICES AS SHOWN IN "POOL DATA" HEREON. LIGHT CONNECTION TO CONFORM TO NATIONAL ELECTRICAL CODE- LATEST EDITION. I 12. ALL METALLIC CONDUITS, PIPING SYSTEMS, I REINFORCED STEEL, LIGHT FIXTURES & HOUSING, METAL I PARTS OF LADDERS, HANDRAILS, DIVING BOARDS & SUPPORTS TO BE BONDED TOGETHER & GROUNDED TO A COMMON GROUND. BONDING CONDUCTOR SHALL NOT BE SMALLER THAN #8 COPPER. r _ 13. NO OVERHEAD OPEN WIRE OVER POOL WATER. 1 14, CARTRIDGE FILTER SHALL HAVE A FILTRATION RATE I NOT TO EXCEED 3 G.P.M. / S.F. OF FILTER AREA. NO BACK- WASH REQUIRED. 15. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND I CHILD SAFETY CONDITIONS AT SITE BEFORE STARTING THE PROJECT. I BARRIER FENCE NO CONTRACTOR SHALL VERIFY LOCATION OF ELECTRICAL SERVICE BY F.P.&L. COMPANY. CLOSER THAN 20" 16. SPECIAL ATTENTION SHALL BE GIVEN TO EXISTING FROM WATERLINE FOUNDATION TO PREVENT UNDERMINING. - - - -" - RAISED AREA ELEV. & GRADE RAISEDCONCRETE EXPOSED & TOPPED m PIPING SCHEMATIC MUST IJ 35 PSI FOR AT (NO SCALE) 'LEAST 30 MIN. :�, RETURN LINE SKIMMER TE BRRAINSAINS 36 " APARTC / ST. LUCIE COUNTY BUILDING D SI N REVIEWED F R OMPLIANC REVI E DATE PLANS AN P IT MUST BE KEPT N JOB SITE OR NO INSPECTION(S) WILL E DE FILTER PUMP I HAIR & LINT CATCHER (COMPONENT OF P OR VTO 41 SLOPE REBAR POOL PERIMETER In REBAR (1) #5 REBAR /OR (2) 1113 REBAR , O_ 8" NO SCALE 22 ft. 6 in. +6" +12" +6" 1" SKIMMER PROVIDE HAND HOLDS AS REQUIRED ANSIINSPE-5-2003 OR MAINTAIN 4" GRABBABLE SURFACE IDETERMINE IN FIELD) VAC LINE COLOR LED 3.5' DEEP SWIMOUTS WHEN PROVIDED SHALL BE AT 20" MAX. BELOW THE WATERLINE 20I' max. 12 TILED STEP EDGES 36" LIGHTED SHEER DESCENT TILED BENCH EDGE PVC HANDRAIL BEIGE RTD-340 *LOCATION OF DECK DRAIN TO BE DETERMINED IN FIELD Per F.R.C. 4501.18 AND ANSI/ NSPI-5-2003 .5" 1.5" : REMOVAL EXISTING. CONCRETE DECK THROUGH A&G N U Q FILE COPY `T(5 v.Aq iSoZ- ayy�L- POOL BARRIER PER FRC R4501.17.1- R4501.17.3 AND ANSI/NSPI-5-1995 SAFETY BARRIER PER FRC R4501.17.1- R4501.17.3 & ASTM5034-95, ASTM D3787- 89, ASTM 653-96 • APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR RESIDENTIAL 6TH EDITION MAX. WIDTH 12' MAX. LENGTH 22.5' MIN. DEPTH 3.5' MAX. DEPTH 5.5' SHAPE CUST ELEVATION T.B.D FILL FROM EXCAVATION HAUL TILE INTERIOR FINISH GEM FILTER CS200 PUMP MAKE PER FBC 4501.20 PUMP HP: POOL FLOPRO VAR 1.65SPA NA FILTRATION PUMP COMPLIANT WITH ANSUAPSPIICC-15 2011 LIGHTS POOL 1 CLR LED SPA NA TRNFORM: POOL 100 WATT SPA NA MAIN DRAIN: POOL 2 SPA NA SKIMMER (1) RETURNS: POOL 3 SPA NA JETS: POOL 2 SPA NA VALVED VAC LINE INCL FILL LINE NA DISCHARGE LINE TO GROUND CHLORINATOR TRU CLEAR SALT SYSTEM LADDER NA DIVING BOARD NA SLIDE NA HEATER AQUACAL TOO VACUUM HEAD INCL POLE INCL VACUUM HOSE INCL BRUSH INCL LEAF SKIMMER INCL TEST KIT INCL TREE / STUMP REMOVAL NA REMOVE EXISITING CONCRETE POOL AND SCREEN INCL SCREEN THROUGH PIONEER BRONZE HANDRAIL RTD-3401NCL ELECTRICAL INCL POOL PATIO CONCRETE FLOCRETE EXISTING PATIO REMOVE EXISTING CONCRETE DECK DRAIN INCL GALLON CAPACITY -POOL 8886 GAL. GALLON CAPACITY SPA- NA GAL, NA TURN -OVER RATE 6 hrs TERMITE TREAT INC BARRIER INCL MAX. WATER VELOCITY - 6 ftJs FROM TRUNK LINES TO 8 ft./s SUCTION LINES. INDS MAX RETURN LINE _SKIMMER MIN. FLOW 25 GPM SURFACE AREA OF POOL -264 SQ. FT 67 LN FT JOB NAME: GALLAGHER ADDRESS: 2322 OAK DRIVE HUTCHINSON ISLAND PERMIT NO.: DATE DRAWN: FEBRUARY 11, 2019 DRAWN BY: DAVE CURLAND DESIGNER APPROVAL: CUSTOMER APPROVAL: SCALE: 1/4" = 1' RAY REINHARD PE # 47041 1010 EASTER LILLY LANE ` UNIT 203 VERO BEACH 3296 0 CONCRETE POOLS, INC ST. MUCIOUNTY ®UILDINd b 5I0 FILE COPY DATE IEWEb FOR COMPLIAN PLANf AN1YPEPMlT MUST BE K 0 JOB 2�­ ()'y L% SITE OR NO INSPECTIONS) LL MADE THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT TO COMPL BE NECESSARY L APP I ABLORDEECODES. WATER LEVEL POOL PATIO NOTE: REMOVE GRATE WELL POINT PLUG FROM MALRBENDUR BEND INTO D CK @ 48" O.C. MAX. DRAIN 8 ATTACH AU%. PUMTIL LINE WHEN EMPTYING POO E BLE DEC" 1 ROW OF WATERLINE TILE4 1 4 i1" THICK , WATERLINE 3.6 - FROM 6 4" SLAB 1' R II LIGH - 00 POWER 1" LIGHT RIOR 2500 FIB #3 STEEL @ 12" O/C E.W. 5.61 WALLS Z g CONDUIT SUPPLY GRATE SHALLH TYPICAL WALL SHALL NOT UNDERWATER BE SECURED IN4 12" TYP. SECTION& FLOOR SLOPE 6" THICK SLOPE UNDERWATE NO PLACE SO WALL FLOOR SLOPES SHALL BE -�.-. LIGHT LIGHT DETAIL THAT TOOLSWELL POINT SCALE) REASONABLY I! coMPLVM4TH GREATER NICHE (NO SCALE) (NO ARE REQUIRED THRu 5 _, CYCOLAC MAIN DRAIN} THAN 11' APPROVED FOR R MOVALSTEEL-TEX FORMGROUND CLAMP ' R KRAFT WALLTHE SLOPE OF THEFLOOR FROM3' /� #3 @ 12" O.C.B.W.TOWARDS THE SHALLOW END WALL CONTINUOUS BOND WIRE THREADENOTE: FOR DEPTHS THE DEEP AREA SHALL NOT EXCEED1 FOOT IN 7FOOTCOMMON TO POOL STEEL, REATER THAN 6'ADD 1- POOL FlNISH'RAILS &EQUIPMENT PLUGAR @ 6" O.C. TO PUMP p. TYPICAL SECTION THRU POOL GRAVEL BED (NO SCALE) CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OR RECORD THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES, SCANNED BY St. Lucie County