Loading...
HomeMy WebLinkAboutNOAMIAMIbADi=}'; DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE'(NOA) Gulf Coast Supply & Manuf 4020 SW 449"' St. Horseshoe Beach, FL. 32648 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street. Ronm 208 Miami. Florida 33173-2d74 T (786) 315-2590 P 096) 315-2599 SCANNED BY SCOPE: St. Lucie County This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Mianti-Dade County Product Control Section (hi'Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted mariner, the hranufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product'is approved as describedherein, and has been designed to comply «rith the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building'Code. DESCRIPTION: 26 ga. GulfRib'Roof Panel over 15132" Plywood deck LABELING: Each unit shall bear.a,permanent label with the manufacturers name or logo, city, state and following statement: "Miami -Dade County Product Control Approved",'unless otherwise noted herein. RENENAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes.shall automatically terminate this NOA, Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTiSENIENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may he displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through G. The submitted documentation was reviewed by Alex Tigera. APPROVED NOA No.: 14-0520.01 Expiration Dauer 10/23/19 Approval Date: 10/23/14 Page 1 of 6 ROOFING SYSTEM APPROVAL: Categorr- Sub-Category Material: Deck Type: Maximum Design Pressure Roofing Metal, Panels (Non -Structural) Steel Wood -159.25 psf TRADE NAVIES OF PRODUCTS MANUFACTURED OR LABELED By APPLICANT: Test Product Product Dimensions Specifications Description 26'ga.'GulfRib Roof Length: various TAS 110 26ga. Steel, Flouropan Coated, Ribbed panel. Paliel Height: 3/4" Width: 3G' (coverage) Thickness: 26ga. (0.0185") MANUFACTURING LOCATION: 1. EVIDENCE SUBMITTED: Test Agency Test Ideirtifier Test Name/Report Date PRI Construction Materials VLS-004-02-01 ASTMG155 02/22/13 Technologies VLS-005-02-01 rSSTM B 117 02/22/13 Farabaugk Engineering and Testing T270-08A TAS 100 07/18/13 T126-07A TAS 100 07/18/13 Force En.oineering and Testing, Inc. 117-go62T-07A-C TAS 125 .07/26/13 NOA No.: 14-0520.01 MtAMI•DADE CoulaTr Expiration Date:.10/23/19 Approval Date: 10/23/14 Page 2 of 6 APPROVED ASSEMBLIES: System: 26Ga. GulfRib Roof Panel Deck Type: Wood, Non -insulated Deck Description: New Construction" b,' or greater plywood or wood plank, or for re -roofing I54,2" or greater plywood. Slope Range: 2": 12" or greater Maximum Uplift See Table A below Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d annular ring shank nails spaced G' o.c. fit reroofing, where the deck is less than '"!3_' thick (Minimum 15/3z") The above attachment method must be in addition to existing attachment. Underlayment: Mininwm underlayment shall be an ASTM D 226 Type II installed with a minimum 4" side -lap aid.6" end -laps. Underlayment shall be fastened with conosion resistant tin -caps and 12 gauge 1 '/+" annular ring -shank nails, spaced G' o.c. at all laps and two staggered rows 12" o.c. in the field of the roll or any approved underlayment liaviug a current NOA. Fire Barrier'Board: Any approved fire barrier 7inving a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation 94. Valleys: Valley construction shall he in compliance with Roofing Application Standard RAS 133 and with the current published installation instructions and details in Gulf Coast Supply & Manufacturing LLC's installation Manual. Metal Panels and install the "26Ga. GulfRib Roof Panel " and accessories incompliance with Gulf Coast Accessories: Supply & Manufacturing LLC's current published installation instructions and details. Flashing, penetrations, valley construction and other details shall be constructed in compliance with the minimum requirements provided in Roofing Application Standards RAS 133. 26Ga. GulfRib Roof Panels shall be fastened with a minimum of 10-15 x 1-1/2" woodgrip corrosion resistant screws. Fasteners shall of sufficient length to penetrate through the sheathing minimum of 3:/i;. Fastenets shall be place in accordance with fastener detail herein is follows: TABLE A MAXINIUNUDESIGN PRESSURES _ Roof Areas Field Perimeter,and Corner' Maximunt'Design Pressures 71.75 psf 459.25 psf Maximum Cli S rein 24" o.c. 12" o.c. 1. Exnn olation shall not be allowed -- - - _ NOA No.: 14-0520.01 MIAMI•DADE COUNTY Expiration Date: 10123/19 "' ' Approval Date: 10/23/14 Page 3 of 6 UmITATIONS 1. Fire classification is not pail of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and comers). 3. Panels tuay he roils formed in continuous lengths from eave to ridge. Maximum lengths shall be as describedit) Roofing Application Standard RAS 133. 4. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement: "Miami -Dade County Product' Control Approved" or with the Miami -Dade County Product Control Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or model. MIAMI•DADE COUNTY 5. All products'listed herein shall have a quality assurance audit in accordance Nvith the Florida Building Code and Rule b 1 G20-3 of the' Florida Administrative Code. NOA No.: 14-0520;01 MIAMFDADECOUNTY Expiration Date: 10/23/19 CI. ' Approval Date. 10/23/14 Page 4 of 6 PROFILE DRAWINGS DETAIL A #9 Woodscrews long enough to penetrate through the sheathing a min. of 3a is 14 x 8' stitch screws. (optional) typ. 24" o.c. for-71.75psf FIELD CONDITION MIAMI•DADECOUrm �FMNYM NOA No.: 14-0520.01 Expiration Date: 10/23119 Approval Date: 10/23/14 Page 5 of 6 DETAILA (CONTINUED) #9 Woodscrews long enough to penetrate through the sheathing a min. offs' " -14 x e" stitch screws. (optional) 2" From Panel End PERIMETER ANTI) CORNER CONDITION END OF THIS ACCEPTANCE NOA No.: 14=0520,01 MIAMKMDE couPITY Expiration Date: f Oh3/19 F.-M570 Approval Date:10/23114 Page 6 of 6