Loading...
HomeMy WebLinkAboutTRUSS4451 ST. LUCIE BLVD FORT PIERCE, FL 34946 PH: 772-409-1010 FX: 772-409-1015 www.AlTruss.com r ',FLp,I Ilp jpRPQRATI)QN; TRUSS ENGINEERING I BUILDER: RENAR PROJECT. MORNINGSIDE COUNTY: ST LUCIE LOT/BLK/MODEL: LOT:103 / MODEL:CAYMAN 1763 / ELEV:B3/ LNI JOB#: 75287 MASTER#: WRMSCMB31-15X10 OPTIONS: 150 SF REAR PORCH NO VALLEYS 4 Lumber design values are in accordance with ANSI/TPI 1-2007 section 6.3 • = A-1 ROOF These truss designs rely on lumber values established by others. TRUSSES A FLORIDA CORPORATION RE: Job WRMSCMB3L1 5X1 0 A-1 Roof Trusses 4451 St LucieBlvd Site Information: Fort Pierce, FL 34946 Customer Info: RENAR DEVELOPMENT CO. Project Name: MORNINGSIDE Lot/Block: Model: CAYMAN 1763 Address: Subdivision: City: County: St Lucie State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/rP[2014 Design Program: MiTek 20/20 0.0 Wind Code: ASCE 7-10 Wind Speed: 160 Roof Load: 37.d psf Floor Load: al0.0D psf FILE ®g>a This package includes 27 individual, dated Truss Design Drawings and 16 Additional Drawings. 11� 1 Lr,�l With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003,section 5 of the Florida Board of Professional Engineers Rules. No. Seal # Truss Name Date No. Seal # Truss Name Date No. Seal # Truss Name Date 1 A0118563 A01 8/29/18 13 A0118575 B04 8129/18 25 A0118587 J2 8129/18 2 A0118564 A02 8/29/18 14 A0118576 B04GE 8129/18 26 A0118588 J5 8/29/18 3 A0118565 A03 8/29/18 15 A0118577 C01G 8129/18 27 A0118589 TO1GE 8/29/18 4 A0118566 A04 8/29/18 16 A0118578 CO2 8129/18 28 STDLO1 STD. DETAIL 8/29/18 5 A0118567 A05 8/29/18 17 A0118579 CO3 8129/18 29 STDL02 STD. DETAIL 8129118 6 A0118568 A06 8/29/18 18 A0118580 C04GE 8129118 30 STDL03 STD. DETAIL 8/29/18 7 A0118569 A07 8/29/18 19 A0118581 C05 8129118 31 STDL04 STD. DETAIL 8129/18 8 A0118570 A08 8/29/18 20 A0118582 CA 8129118 32 STDL05 STD. DETAIL 8129/18 9 A0118571 A09GE 8129/18 21 A0118583 CJ3 8129/18 33 STDL06 STD. DETAIL 8129/18 10 A0118572 B01GE 8/29/18 22 A0118584 D01 8129/18 34 STDL07 STD. DETAIL 8/29/18 11 A0118573 B02 8/29/18 23 A0118585 HJ2 . 8/29118 35 STDLO8 STD. DETAIL 8/29/18 12 1 A0118574 1 B03 8/29/18 124 1 A0118586 1 J5 8/29118 36 1 STDL09 I STD. DETAIL 18129118 The truss drawing(s) referenced have been prepared by MiTek Industries, Inc. under my direct supervision based on the parameters provided byA-1 Roof Trusses, Ltd. Truss Design Engineer's Name: Anthony Tombo III My license renewal date for the stale of Florida is February 28,2019. NOTE -The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of components for any particular building is the responsibility of the building designer, perANS0TP14 Sec. 2. The Truss Design Drawing(s)(TDD[s]) referenced have been prepared based on the construction documents (also referred to at times as 'Structural Engineering Documents) provided by the Building Designer indicating the nature and character of the work. The design criteria therein have been transferred to Anthony Tombo III PE by [At Roof Trusses or specific location]. These TDDs (also referred to at times as 'Structural Engineering Documental are specialty structural component designs and may be part of the projects deferred or phased submittals. As a Truss Design Engineer (i.e., Specialty Engineer), the seal here and on the Too represents an acceptance of professionaAnthony T. engineering responsibility for the design of the single Truss depicted on the TDD only. The Building Designer is responsible for and shall coordinate and review the TDDs for compatibility with their written engineering requirements. Please review all TDDs and all related notes. 3B BCA2210000 GO 004C 1287 DF Page 1 of 2 #A-1 -R5 ROOF TU5E5 AFLORMA CORPORATION RE: Job WRMSCMB3L15X10 No. Seal # Truss Name Date 37 STDL10 STD. DETAIL 8/29118 38 ST01-11 STD. DETAIL 8129/18 39 STDL12 STD. DETAIL 8/29/18 40 STDL13 STD. DETAIL 8/29/18 41 STDL14 STD. DETAIL 8/29118 42 1 STDL15 I STD. DETAIL 8/29118 43 STDL16 STD. DETAIL 8129/18 Lumber design values are in accordance with ANSI/TPI 1-2007 section 6.3 These truss designs rely on lumber values established by others. Page 2 of 2 Job Truss Tress Type Dry Ply A0118563 WRMSCMB3L15X10 A01 Roof Special 3 1 �RENARMORNINGSIDE Job Reference optional) A-1 Roof Trusses, Foil Pierce, FL 34946. design@altross.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 6.00 FIT 5.10 MT20H8= I 17 16 300 _ 3x6 = 4x6 = 2x4 II 3X4 II 5x12 3x6 1528:41 Dead Lard Defl. =1/8 in 7-3A 11-10-10 15-6-0 19-1-6 27-10.2 7-3A 4-7-1 3-7-1 1 3-7-6 8-8-12 1 10.1-14 Plate Offsets (X Y)-- I7:0-3-0,0-3-0I, 111:0-4-8,0-3-01 113:0-6-8 0.2-81 I15:0-5-4,Edael LOADING(psf) SPACING- 2-M CSI. DEFL. in floc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.93 Ved(LL) 0.35 14 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.88 Vert(CT) -0.48 11-12 >945 240 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.99 HOrz(CT) 0.30 9 n/a rda BCDL 10.0 Code FBC2017/TPI2014 Matrix-MSH Weight:22211b FT=10% LUMBER - TOP CHORD 2X4 SP M 30 •Except- T1: 2x4 SP No.2 BOTCHORD 2x4 SP N0.2 *Except' B2: 2x4 SP No.3, B6: 2x4 SP M 30 WEBS 2x4 SP No.3 *Except' W3,W7,W9: 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied. BOTCHORD Rigid ceiling directly applied or 4-2-6 oc bracing. WEBS 1 Row at midpt 11-13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation nuide. REACTIONS. (lb/size) 2 = 148210-7-10 (min. 0-1-12) 9 = 148210-7-10 (min.0-1-12) Max Ho¢ 2 = -167(LC 10) Max Uplift 2 = -370(LC 12) 9 = -368(LC 13) Max Grav 2 = 1482(LC 1) 9 = 1482(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=2654/1639, 3-4=4224/2520, 4-5=-3578/2091, 5-6=3485/2116, 6-7=-3262/1858, 7-8=2382/1529, 8-9=2684/1736 BOTCHORD 2-17=-1276/2306, 4-15=211/377, 14-15=-2007/3890, 13-14=-1104/2894, 6-13=994l2140, 9-11=-141412374 WEBS 3-17=-1304/841, 15-17=1485/2692, 3-15=-630/1441, 4-14=7671718, 11-13=1424/27B4, 7-13=14/455, WEBS 3-17=-1304/841, 15-17=148512692, 3-15=630/1441, 4-14=-7671718, 11-13=142412784, 7-13=14/455, 7-1 1=1 006/570, 8-11=-3891478, 6-14=547/700 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; VuIr160mph (3-second gust) Vasd=124mph; TCOL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 370 lb uplift at joint 2 and 368 lb uplift at joint 9. 7) This truss is designed for a creep factor of 1.50, which is used to calculate the Vert(CT) deflection per ANSI/TPI 1. The building designer shall verify that this parameter fits with the intended use of this component. LOAD CASE(S) Standard redq'Iuatln74mm�b'Hl1[Fnhf9(lfII4j HIa4mWt(PF.gAM(IfiPtl(46l')4M1[Pom4'he irgidplem,FndMdnnM1�Lm M4kMq!161vdbrMl.Isb4lLWaxellaiNkeme. Wn+RemdndnbleP,mj WI,Y,wnu1HS�MbmIb W19'Jhb,Y lfelmf lmqfgseib,Sµ1E(IqefybutlngWnPeanovymd4PdnmleeQefgnyoneMrb4lnpib5xj,imaL9�le4 Wvh,dfPiLlL peu�ur'm.Wgo�ns2,LA /Nthny T. Tmbo 111, P.E. deudeurm+MgluM9udmPrblmtlbAm.dO.m',rRatd,gY„bitlrH4niP'.etr�ntlbGGbKWb WfaYgo4vfW.0egp,KddTOdmbNneddimvblM4*Gia'ge. e,e4uelYm9df Ybn`N,bIQtl 580083 44xryM(eW4ewt.Neo+XMtlbROdbrxm�W piltlu�dbMPq Oerar.SxgCansm',OPpIi61MRImr4anMr.W4pmtlp4u 1r4hL:b:npndlxnnlrmntl44n, RnA•tlnvMepfrysesllmvr+/au,u'n 44515t. Lucie Blvd. ,4edulGdenrmdgeAneimyMmimm�ma mu ssuugrgwxmlddvaAq:in,.Irc+Sn+abpmderbas amzx+rmnnWmtldml � Fort Pirece,FL 34946 (e h®7PIAMI IoalbmsesAnlEno I Iomhe N.Pt to i dtlmaooltlidomnml,ino to n mlidREvieoNBerrinn e�mi{vee6om AI loolborz+-AeStee i Lmholll,L[. Pp'1 PPe 9 nAP P P• Job Truss Truss Type Dry Ply RENAR MORN INGSIDE 4 WRMSCM631-15X10 A02 Scissor 3 1 A0118564 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@albuss.com 1.5x4 a 3 m12 0 448 > Run: 8.210 s May 18 2018 Print: 8.210 s M ID:ld 0OXyyT61Bi_T 2 19440 25a4 31 6-04 6-04 5 6.00 12 5.6 = 5 5x6 G 5x6 1, 4 6 12 6.8 14 13 11 0 3x8 MT20HS� 3x8 MT20 3x4 c 3.00 12 3.4 c 1.5x4 II 1.5x4 II 2018 MiTek Industries, Inc. Wed Aug 29 15:28:42 2018 Deaf Load O 11. = 51161n 1.5x4 s 7 1 1 4 via 19 ro LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) I/dell Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.67 Vert(LL) 0.5512-14 >826 360 TCDL 7.0 Lumber OOL 1.25 BC 0.84 Vert(CT) -0.8012-14 >570 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.93 HOR(CT) 0.50 8 n/a n/a BCDL 10.0 Code FBC2017rTP12014 Matrix-MSH LUMBER - TOP CHORD 2x4 SP N0.2'Except' Tt: 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc pudins. BOT CHORD Rigid ceiling directly applied or4-7-10 oc bracing. Except: 4-8-0 oc bracing: 8-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1482/0-7-10 (min. 0-1-11) 8 = 1482/0-7-10 (min.0-1-11) Max Horz 2 = -166(LC 10) Max Uplift 2 = -069(LC 12) 8 = -369(LC 13) Max Grav 2 = 1482(LC 1) 8 = 1482(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=4676/2810, 3-4=4314/2537, 4-5=-3129/1785, 5-6=-3129/1785, 6-7=4341/2562, 7-8=-466012828 BOT CHORD 2-14=2402/4233, 13-14=-183113605, 12-13=1827/3640, 11-12=1829/3643, 10-1 1=1 842/3607, 8-10=-2418/4245 WEBS 5-12=127812430, 6-12=-8501786, 6-1O=262/633, 7-1O=319/445, WEBS 5-12=12782430, 6-12=850f786, 6-10=-262/633, 7-10=319/445, 4-12=848f781, 4-14=-257/625, 3-14=318/465 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; canfilever left and right exposed; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 2, 8 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 369lb uplift at joint 2 and 369 lb uplift at joint 8. 8) This truss is designed for a creep factor of 1.50. which is used to calculate the Vert(CT) deflection per ANSI/TPI 1. The building designer shall verify that this parameter fits with the intended use of this component. LOAD CASE(S) Standard 5x8 1.5.4 1 4x8 // PLATES GRIP MT20 2441190 MT20HS 1871143 Weight:200lb FT=10% Gpq.MUXvgYln,ertr NnC: mS44({Na}m31 kkear. Wnt Mnu vatleMlW.sy On fMlbtlPl.tatl.+dmlMt.Mlrn�hQOn9IP ®tr1ILI. Nth P.SI bINW,%171LLICPJ NeonmlVn�4tm1YYL9aY:4t Ite4ru Ytry,lgee{Y.Se;m!6¢M L W PgNe r,pv,coo.vp,p4rWMuryerurrywNgYhlaptltrujtlrc3hµmlebrNU�.,la1Rt 1itPn,vpm Wquee„vaodtl} NWOdII'.M Anthiony T. 81, P.E. dwpmlmtr,pYrynuaymam.elno.,,,.Yo.ni.raeJ,.m.ml.nigpnp...o-�m+unam.vcwmMl.rqM,mml.nyp,mamaomr,.f,u,x6almiMyl�gmq. mneo.dsngJnYe.nyaatf!4 x80083 6�NYalYtryd4a:Nr.{AebDNYb1IgdM1rm�ofmPJiu6MPNgInp6LlgtYa@tTl,•PNrWh111q WnMrNYxwiPJSL 11FIRbiY:rpa�Ja,sNEnrnrlYBatRYpa.t fMfgn}xMrmtrMNe:am �q$t $I. LYCIC 61Vd. Lucie denudd 4rye4nmyM,uanmglp®Inn YprLL 0rinu Y:¢[opn Ylrlhlmfallagn,vl>•s11me4^exmr MA418r}*b4tmmeml4NelM1l. Fad Pierce, n 34946 Oppilll®alibi Iwttmas-UOoryLlamEelOPJ. 4p,Ntlmoeeldir dYvmm,wmglmm,ispolAeA•i0emllevNieepmm�uu6em411odhruerleRmpLiemlol0,P.1. Job Truss Truss Type Ory Ply RENARMORNINGSIDE WRMSCMB3L15X10 A03 Scissor 10 1 A0118565 Job Reference o tionet A-1 Roof Trusses, Fort Pierce, FL 34946, design@altmss.com Run: 8210 s May 18 2018 Print 8.21U s May l8 2U18 MI I eK Ineuslnes, Inc. Wed AUg 291b28:42 2U18 6.00 12 5.6 = Dead Load DeO. = Sltfi In 4x8 4x8 2 3B-" 9910-0 -012 10-4 Plate Offsets KY)- T2:0-1-14,Edael T4:0-3-00-3-01 [6:0-3-0 0-3-01 [8:0-1-14 Edael LOADING(psf) SPACING- 24)-0 CSI. DEFL. in (roc) I/deg L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.66 Vert(LL) 0.57 12-14 >806 360 MT20 2441190 TCOL 7.0 Lumber DOL 1.25 BC 0.84 Vert(CT) -0.82 12-14 >557 240 MT20HS 187/143 BCLL 0.0 ' Rep Stress Ina YES WB 0.93 Horz(CT) 0.52 8 n1a nla BCDL 10.0 Code FBC2017fTP12014 Matrix-MSH Weight:179Ib FT=10% LUMBER - TOP CHORD 2x4 SP No2'Excepe T1: 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc puffins. BOTCHORD Rigid ceiling directly applied or 4-7-7 oc bmcing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1482/0-7-10 (min. 0-1-11) 8 = 1482/0-7-10 (min. 0-1-11) Max Horz 2 = -166(LC 10) Max Uplift 2 = -369(LC 12) 8 = -369(LC 13) Max Grav 2 = 1482(LC 1) 8 = 1482(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=4676/2809, 3-0=4314/2536, 4-5=3130/1786, 5-6=3130/1786, 6-7=-4314/2551, 7-8=41676/2830 BOTCHORD 2-14=2401/4233, 13-14=183213605, 12-13=182713641, 11-12=1832/3641, 10-11=-183713605, 8-1O=2423/4233 WEBS 5-1 2=-1 27912431, 6-12=-8481779, 6-10=-254/625, 7-10=318/464, 4-12=-848f780,4-14=-256/625, 3-14=-318/465 WEBS 5-12=127912431, 6-12=-848f779, 6-1 O=254/625, 7-1 O=318/464, 4-12=-8481780, 4-14=256/625, 3-14=318/465 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and GC Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load noncencurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 2, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify rapacity of beating surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 369 lb uplift at joint 2 and 369 lb uplift at joint B. 8) This truss is designed for a creep factor of 1.50, which is used to calculate the Vert(CT) deflection per ANSIfrPI 1. The building designer shall verify that this parameter fits with the intended use of this component. LOAD CASE(S) Standard W.,N.ft-'* ..." VC1 fluvargaurt Reatno 'aam orsurmrl110018urrle. r.gmumeM.paMv[M%WWO,].l.n¢rtlwemvsas,mr. oaememuaednwmo..y OLIme.Irm�10 Y Mb bd4. F m L.4m Mgefryuege.y.uh Op4.bud,.mIDrspuunm mrm db0dneudbmlvptlEessjefnu 14m.ft W"'e Mt hr!r'Pvuannntl9vNe.;vedtlh Anthony T. Tmbo 111, P.E. ¢Im0W.,tNWfuW bl,dfaY,r W MI. N9¢rrib IN ol,W—db lm.itld'Iv aW.meNm naft" MNh>NWid NW'MI.Wnm,ne.L..'OM.b mrwwmnmpklndbw"In,.'."b'v6u,'6YINIb(hI'MIXl.e,damlfpWplm MI 44515t. Wde Blvd. ecnurddlnoam.yimwn.rttfharm.mma NNssncpapnYrLlb Wd.r&.1.,.bnfla.F4ure.f4aq lBggm.(mmmnkW.Inf. � Fort Pierre, FL 34946 (o M0101E AI raalLrnes�Nlloe Lirmla O, P.F. Be iode4iverhEirlomnem,iov Ioriq.ir �o6TitedribevllEernvev nieoh.m Al leotLeue%Asher LlomlrlO,Ef. - n"1 r v 9 1 lei 7 -_.. -80083 ... Job Tmss Truss Type Oty MORNINGSIDE i WRMSCMB3L15X10 A04 ROOF SPECIAL 4 [lY 1 �RENAR A0118566 Job Reference (optional) - A-1 Roof Trusses, Fort Pierce, FL 34946, design@albuss.mm Run: 8.210 s May 18 600 F12 7x6 II 18 17 "" 4x10 = - , 3.6 = 5.6 = 21 II 1.Sx4 II 3.00 12 Us 8x8 = 1.5x4 11 11.7-10 2t4?-10 23 2 &1-0 11-1-10 L4 19-00 11-1 211F2 29b-0 066U 3 10 Oi" IO -11-1 I1-9-0B &2-14 84i-0 oa o oa-0 2915:28:43 Dead Lood Defl. = 3116 in Plate Offsets (X,Y)- [610-1-12 Edcel 18:0-3-0 0-3-01. [9:0-0-10,Edgel [12:0-5-12,0-5-41 [15:0-5-12 0-4-41 [18:0-3-0 0-1-121 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.93 Vert(ILL) 0.4711-12 >974 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.85 Vert(CT) -0.6511-12 >699 240 BCLL 0.0 ' Rep Stress Incr YES WB 1.00 Hou(CT) 0.36 9 We We BCDL 10.0 Code FBC2017/rP12014 Matrix-MSH Weight: 2221b FT =10% LUMBER - TOP CHORD 2x4 SP N0.2 *Except* T1,T4: 2x4 SP M 30 BOT CHORD 2x4 SP N0.2'ExcepV B2,B4: 2x4 SP No.3, B5: 2x4 SP M 30 WEBS 2x4 SP No.3'Except' W6: 2x4 SP No.2- OTHERS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied. BOTCHORD Rigid ceiling directly applied or 4-9-3 oc bracing. Except: 10-0-0 oc bracing: 15-17 WEBS 1 Row at midpt 4.14, 6-14, 6-12 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1491/0-7-10 (min.0-1-12) 9 = 1485/0-7-10 (min.0-1-11) Max Horz 2 = -166(LC 10) Max Uplift 2 = -365(LC 12) 9 = -367(LC 13) Max Grav 2 = 1491(LC 1) 9 = 1485(LC 1) FORCES. (lb) Max. CompJMax. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-263511604, 3-4=2700/1747, 4-5=-182211223, 5-6=171711250. 6-7=-3863/2402, 7-8=-4601/2946, 8-9=-4661/2731 BOT CHORD 2-18=-123312282, 4-15=-310/655, 14-15=-125412423, 7-12=-511/558, 11 -1 2=1 67813630, 9-11=232014205 WEBS 3-18=466/340,15-18=-1123/2282, WEBS 3-18=466/340, 15-18=-112312282, 4-14=1036/801, 6-14=-492198, 7-11=794/860, 8-11=352/502, 12-14=-685/1887, 6-12=170813244 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vul[=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.0psf; h=13ft; Cat. II; Exp B; End., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 9 considers parallel to grain value using ANSI/rPI 1 angle to grain formula. Building designer should verify rapacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 365 Ib uplift at joint 2 and 367 lb uplift at joint 9. 7) This truss is designed for a creep factor of 1.50. which is used to calculate the Vert(CT) deflection per ANSI/TPI 1. The building designer shall verify that this parameter fits with the intended use of this component. LOAD CASE(S) Standard @q�Mu4nnprmh.n'altlenA2flt!Rj0.rdLLINOr L'CMn(6104jx9jurffnFii•trraa l•d�6upr•odmmntle�n.NimsMpbMIIIWmhIAvr14•a0.rLWv,WO'ni'en,_ItlnvaM.v,tlMeYN9. Y N,uumm,rkNYLF tlYnl%IYF,LL 4rtm�1¢pfyse{1L!;hE/hp,QleWwglf9ipmrtovunadnl�,MWtlg9vpnlc lAllbm N44h4�etmstq�pY.n1�.9.nbRl.htpnuapulwlgmBbt+mtl�T.M Anthony P.E. n d 4u 1m1b TW415>mrwilg ld em.N&. Srh3V,glWNMIA brx.•bbwdbK%M Wbbd1•xspNsMMI. 11,9/,wdbapdafitlind4eim•OEdgl+r+p ny,I,fMN,MYMpp} F bngmb'" v 80snC0171, %80083 bnl•laym olOmm.o•rsw,•.bsrodmrnmsM uuvewxwbp•rp.rd cotwf.s>znspe�wnnmmntrtme,oya.tms Fs rm�u.dn.,r ss I ;6p••e 44515L Lucie 6lyd. N'bMw hysy b,1,;gr.m.;mip bp. dM ,x•Firm,41pr6smgMgaurn9qh•!r•Inmtlrel tam:,acqupmermbtr4,rM.pe,•[,:s!roaf.nwembl4awTSFmnnlei Fort Pierce, FL 34946 (apphEl®1016 A�I fed Lssns-AM�LIomM N.li IepMsaimdendem®etl,iooglmnnp�ol3nedriaeN®erminpenm4erhaoA-I lodtnnerArdnerLl•oE•IryP.L Job Truss Type RENAR MORN INGSIDE AO118567 WRMSCMB3L15X1O �Tnuss A05 HIP CAT �Qty 1 �Ply 1 Job Reference o lional A-1 Root Trusses, Fort Pierce, FL 34946. design@altrusswrn Run: 8.210a May 182018 Print 8.210 s May 182018 M1iTek 10 60012 5a6= 6x6= Inc Wed Aug 29 15:28:44 2018 20 19 3x4 = — 11 3.6 = 6.6 = 3x4 II 4><6 _ 1.5x4 II 3.00 12 4x8> 8x8 = LOADING(psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.26 BCLL 0.0 ' Rep Stress Incr YES BCDL 10.0 Code FBC2017/TP12014 LUMBER - TOP CHORD 2x4 SP N0.2'Except' T4,T5: 2x4 SP M 30 BOTCHORD 2x4 SP No.2'ExcepC B2,B4: 2x4 SP No.3, B5: 2x4 SP M 30 WEBS 2x4 SP No.3 *Except' W6: 2x4 SP No.2 OTHERS 2x4 SP No.3 WEDGE Right: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-8-8 oc purins. BOTCHORD Rigid ceiling directly applied or 4-8-13 oc bracing. Except: 10-0-0 oc bracing: 17-19 WEBS 1 Row at midpt 4-16, 6-15, 7-12, 6-13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1491/0-7-10 (min.0-1-12) 10 = 1485/0-7-10 (min.0-1-11) Max Horz 2 = -159(LC 10) Max Uplift 2 = -359(LC 12) 10 = -362(LC 13) Max Grav 2 = 1491(LC 1) 10 = 1485(LC 1) FORCES. (Ib) Max. CompJMax. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=2721/1649, 3-0=2697/1687, 4-5=187611277, 5-6=1602/1239, 6-7=3879/2412, 7-8=-466512991, 8-9=4517/2738, 9-10=468912737 BOTCHORD 2-20=1302/2377, 4-17=-229/596, 1.5x4 II 2 11-1A 2 CSI. DEFL. in (loc) I/deft Ud TC 0.71 Vert(L-) 0.4712-13 >968 360 BC 0.85 Vert(CT) -0.6712-13 >681 240 WB 0.85 Horz(CT) 0.37 10 We n/a Matrix-MSH BOTCHORD 2-20=1 30212377,4-17=-229/596, LOAD CASE(5) 16-17=1224/2404, 15-16=-61511602, Standard 7-13=532/615, 12-13=-1677/3640, 10-12=2333/4230 WEBS 3-20=-267/251,17-20=-117912225, 4-16=975/739, 5-16=2671546, 6-15=1358/503, 7-12=-8391887, 8-12=344/505, 13-15=-823/2180, 6-13=1821/3504 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult--I 60mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exledor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Pmvide adequate drainage to prevent water pending. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 pat bottom chard live load noncwncurrent with any other live loads. 6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 10 considers parallel to grain value using ANSITPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 3591b uplift at joint 2 and 362 Ito uplift at joint 10. 9) This truss is designed for a creep factor of 1.50, which is used to calculate the Vert(CT) deflection per ANSI/TPI 1. The building designer shall verify that this parameter fits with the intended use of this component. Dead Load car. = 31161n PLATES GRIP MT20 2441190 MT20HS 1871143 Weight:236lb FT=10% renq.mmmngM,nwm'11 tlEfMfd611ndIrAa[iUftdfLlEe9P[GnllEx(xTa?xrrrlr,eln'mt reddmupleextlmeY„d,hnm,LmB.q,R,ngirtC,nlbinWll.fabgltltlsem YMb4, m. Cdn,NnmmiiomM,aj YOtlmmmrxndmkmlmmMnbm4 beG,upevplgaePr.lXultLp:4muLngl9npnrnovupmpmpMmNyu-�gnyeuluaMmlePmmveJe6 vLgnJaANEN del;L lY4apn:npuL9pmfev!,r�a,Mll Anthony T. Tornbo 111• P.E. tlmd Wrn,m, WY kftrr, ,in,N.U.ntu:xuMTLe mWlp4ep.emmedm Kb K vdmmtl Wipnk vlMN,rx,a'im MNa6H m, dmimutl.bglxR{ape6fdmen.'" b 6.' Xqd �80083 ■ \� mYpM�drtb. sae GMg6Mdm mtm p4 !ttl0nMg4,as M b 9aK d N l tlW rt dm mlp pAla5 :b ymKan nl Mn[YLnvdq e.t ,h:S4pas tmtYtdReq t 44515L WriQ Blvd. l/ ,ge.luldWlnfKmq,dpOmhq Nelrvn RhN IbP,vh:¢(gnmh1E141fIpMp,elnu SlcL6pedmr Wfq Ngya!IYnnn1,W YfiL Font Pierce, FL 34946 llppi'mo 1011A 1WIT..ses-Ao0aryl.Iemtelll.hF. BepndeaweollAisdmomem,aoplam,isp,oAAted xiltemMe nrinee pe,misueehem A4looRnnel.Ae,Aoopi: rom0n10, r.f. Job Truss Truss Type Oty Ply a WRMSCMB31-15X1O AO6 HIP CAT 1 1 �RENARIVIORNINGSIDE A0118568 Job Reference (optional) A-1 Roix Trusses, torl vie". FL 34946, daSign@altruss.com 0 600 12 Run: 8.210 s May 18 2018 Print 8.210 s May 18 2018 MTek 1314 5x10 5x8 II 3x4 II Inc. Wed Aua 29 15:28:452018 20 19 3x4= V. 3. = 6.6 = 3x4 II 1.5x4 II 3.00 12 4xa x 8xe = 7.8 = 61-t 11-1-1n 11I)I10 10o-12 -11 20-1od-10.14 rg-1p z3,yz so-a-11 se.on s1-0 549 0-60 as2 0810 1bU Dead Load Defl. =114 in Plate Oftsets(X,Y)- [7:0-2-00-2-81 f10:0-1-14Ed0e1 fl3:0-7-0,0-3-101 [15:0-1-120-2-01 f17:0-5-120714] LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) Ildefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.64 Ved(LL) -0.5212-13 >869 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.98 Vert(CT) -0.7712-13 >590 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.95 Hom(CT) 0.49 10 nla We BCDL 10.0 Code FBC20177rP12014 Matrix-MSH Weight:2361b FT = 10% LUMBER - TOP CHORD 2x4 SP M 30'Except' T3: 2x4 SP No.2 BOT CHORD 2x4 SP N0.2 *Except* B2,B4: 2x4 SP No.3, B5: 2x4 SP M130 WEBS - 2x4 SP No.3 *Except* W5,W7: 2x4 SP No.2, W8: 2x4 SP M 30 OTHERS 2x4 SP No.3 WEDGE Right: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-8-6 oc pudins. BOT CHORD Rigid ceiling directly applied or4-8-13 oc bracing. Except: 10-0-0 oc bracing: 17-19 WEBS 1 Row at midpt 6-15 2 Rows at 1/3 pis 7-15 MTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 149110-7-10 (min.0-1-12) 10 = 148510-7-10 (min. 0-1-11) Max Horz 2 = -142(LC 10) Max: Uplift 2 = -346(LC 12) 10 = -349(LC 13) Max Grav 2 = 1491(LC 1) 10 = 1485(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-272711634,3-4=-2685/1640, 4-5=-2622/1657, 5-6=-2044/1363, 6-7=-1783/1297, 7-8=-3589/2235, 8-9=-3752/2106, 9-10=-470812721 BOT CHORD 2-20=129312384, 5-17=-256/572, BOTCHORD 2-20=-129312384, 5-17=-256/572, LOAD CASE(S) 16-17=1 16812365,16-31=734/1782, Standard 15-31=734/1782,8-13=-2311391, 12-13=2324/4260, 10-12=-2320/4250 WEBS 3-20=2661257, 17-20=-120312211. 5-16=-810/602, 6-16=316/617, 7-15=-371511603, 9-13=-8791776, 9-12=O/281, 7-13=2586/5316, 13-15=170214204 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. - 4) This truss has been designed for a 10.0 psf bottom chord live load nonwncurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 240-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Bearing at joint(s) 10 considers parallel to grain value using ANS[TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 346 lb uplift at joint 2 and 349 It, uplift at joint 10. 8) This truss is designed for a creep factor of 1.50, which is used to calculate the Vert(CT) deflection per ANSI/TPI 1. The building designer shall verify that this parameter fits with the intended use of this component. huq.M1me(mgy Nrh 41n['rrnSSR(YLLIrj9liLLleOl[3lN6mlGtl(biTJ![nrP�6l bry6uPP�drtdvxnne 1:,u0nT01.gIIW,vltrle�I.ISY4rlWn L•lkrent WnfNe.:uOMaMlP coy )IleYmvu,Itnflpb,W bM1iIIII,M,LL 1111mfONpfryw{,u!p¢:}e4eM.Of eYnglEA„yemRompx,fbpLVvlv},en,lrypd9gkgln4tlkYlelmfl•ry�e1nM11UulI.rYnIM11.'YL•;y,nnopim,b;mbns+•62� Anthony T. Tombo 111, P.E. rfd4ksla lu,gldM1q-b,�ryerNn,.dhOm.M10.m1,AedrpxaO,INEgpuym,udnpen dN X N a WA! Wbl"w Wlxl'hpi,NoWW"'uetlwdNimvlh0gl#ignry. b,nMis of ki,"k bnyaeten/ 480083 ' YMin W""el0rrxn a. wo"WOM N,.wmhJwtlMPllq fP V, 4kmin:PxjPNiilYIl lx dnnm'fna:bp:iPlyx lMaLCLngeaMmvYb1n141nnP,1:nt M.pePn Wlnufafeea,w':.1 44515t. Lurie Blvd. Arnu14uN11rfnMIPdIPx911dlnne,b,la,tms n'sfgrtnnlLl rxl4flingv,xL !vfnbxialwfnlWq I49><n0nI4NgIM1l. Fed Pierce, FL 34946 eprnlu®Inb/ I InM..es-Avuagl, Ie4r N, 13. LWoiv4iexofdhlvmnem,uovrlum,ilpmlTced Yriemduhitnopehmilwvh4n A -I loollmuh MlmrLlavEelO, P.L Job Truss Truss Type cityPly RENARMORNINGSIDE WRMSCMB3L15X1O AO7 Hip Structural Gable 1 1 AO118569 Job Reference o tional A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.cem 0 Run: 8.210 s May 18 2018 Print: 8210 s May 1132018 MITex Industries, Inc, 6.00 12 Sx6= 3x4 = 5x10 MT201-!5� 22 21---3x8= 17— 15 13 3x6 = 4x4 = 2x4 II 18 76 14 1.5x4 it 4.6 it 3.6 = 3x6 = 5.6 = Dead Load Deb. =1116 in LOADING(psf) SPACING- 2-M CSI. DEFL. in (too) I/deb Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.64 Vert(LL) 0.13 13-28 >771 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.79 Vert(CT) -0.34 18-19 >808 240 MT20HS 187/143 BCLL 0.0 ' Rep Stress Incr YES WB 0.40 Horz(CT) 0.01 15 n/a n/a . BCDL 10.0 Code FBC2017/TP12014 Matrix-MSH Weight:2201b FT=10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP N0.2'Except' B2,B5: 2x4 SP No.3 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or4-6-6 oc pudins. BOTCHORD Rigid ceiling directly applied or 6-0-0 Be bracing. Except: 4-1-0 oc bracing: 15-18 WEBS 1 Row at midpt 7-18 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 14-11-10 except Qt=length) 2=0-7-10, 16=0-3-8. (lb) - Max Horz 2=-126(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 16 except 2=247(1-C 12), 15=-365(LC 9), 13=-158(LC 13). l l=-148(LC 13) Max Grav All reactions 250lb or less at joint(s) 16 except 2=854(LC 23), 15=1662(LC 1), 13=345(LC 24), 11=330(LC 24), 11=304(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - Al forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1301/888,3-4=-9661759, 4-5=896/775, 5-6=675/650, 6-7=-577/617, 7-8=0/442, 8-9=01509, 9-10=-71403 BOTCHORD 2-22=-603/1'105, 5-20=277/376, 19-20=3261802, 15-18=1300/640, 8-18=-421/214 WEBS 20-22=-596/1007, 3-20=-348/338, WEBS 20-22=59611007, 3-20=-348/338, 5-19=487/462, 7-19=225/634, 7-18=9841583, 10-15=3921336 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.OpsF, h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)*This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)16 except (jl=lb) 2=247, 15=365, 13=158, 11=148, 11=148. 8) This truss is designed for a creep factor of 1.50, which is used to calculate the Vert(CT) defection per ANSUTPI 1. The building designer shall verify that this parameter fits with the intended use of this component. LOAD CASE(S) Standard r•w�,Y.pymnY�uaunnuoNilFr;auwraYlumm�nrnrrrymm+w:warmYx mryx,qn=tl.,m,.Iem�.bn,mm�r>,.w;�;mMwvul.Iw,u.rtlwmaxlm,.e mtrunY.x,wa.uF:0.mr kLl®y1bb WNwdb YlCabMd 4.Fmf Er': bgvfa.S1,L6�IgbalYWe%G-1u>naiavqu,iby,MWmryd�,npulllrbbhJytl}�aim,LlGlbYlnwp„aN�M1l. hlnynwjip YfyaC iegiy Anthony T. Tomto 111, V.E. Wmtl Ylm,b9Yl9sin4beYeldbim,bC.,s lwYhdMoYi'a41T09.YYapedb91.Y6fMY'aYefMvl WRFI. in 9PMd41:8W NMImtl YImAb'^Wimeu3age..Yla.IM6gvW bpa 'NIA '80083 b YffirbYp,tlfrcrs,_fOennM.1,tl.lYp,mndpbb„IYMYa<npuYOlNmtaT.PlplWFlflN4nv,:MmdYpNr•Y¢IM1IHm,b, �l4MmIMdYl:,ngnpe.'m�Y,y4laerimtY.M(+m,�n, 4451 St. Lude Blvd. au.mYvlF,rWn9MWbn6ghOrnnbWrt mumErvPFSarthUIbl.YgMrn.xi,mSrynFg.,xtlgYM.0 a+q�alknnnNW4Ti' � Fort Piwce, FL 34946 ( Eta 101611 /aalGnutldly LIvnY10., 1d,t Nadinaltbidanmem,iv 6,m,h oE3irtEuevmde n"T.ev sSve trvbbl ladle,+n�Av0a Lla iolll,P,E.._ _ . antq % vVt R n fog % _. .. . Job Truss Type PN WRMSCMB3L15X10 �Truss A08 Hip �Qty 1 1 �RENARMORNINGSIDE A0118570 Job Reference o bonal A-1 Root l russes, Fort Pierce, FL 34946, design@altruss.com I�' 5.6 = Run: 8.210 s Mav 18 2018 Print 8.210 s Mav 18 2018 MTek 3x4 = 5.6 = Inc. Wed Aua 29 15:28:46 2018 Dead Lead Defl. =118 in 1.5x411 3x6= 6x6= 3x4= 3.6= 3xfi = 318 = 316 = LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) Well Ltd PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.65 Ved(LL) -0.3212-14 >884 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.89 Vert(CT) -0.45 12-14 >616 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.70 Horz(CT) 0.02 12 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Matrix-MSH Weight:196lb FT=10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-6-4 oc purins. BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 5-12, 6-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 77710-7-10 (min. 0-1-8) 12 = 1828/0-7-10 (min.0-2-3) 8 = 358/0-7-10 (min. 0-1-8) Max Horz 2 = -114(LC 10) Max Uplift 2 = --219(LC 12) 12 = -553(LC 9) 8 = -248(LC 8) Max Grav 2 = 807(LC 23) 12 = 1828(LC 1) 8 = 413(LC 24) FORCES. Qb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-1151/588, 3-4=6821381, 4-5=-540/390,5-6=318/606, 6-7=-321f762, 7-8=313/516 BOTCHORD 2-15>326/963, 14-15=-3261963, 13-14=311276, 13-22=-311276, 22-23=311276, 12-23=-31/276, 11-12=3481498, 11-24=-348/498, 24-25=348/498, 10-25=-3481498, 8-10=298/219 WEBS 3-14=-533/508, 5-14=-2931582, WEBS 3-14=533/508, 5-14=-293/582, 5-12=1109f793, 6-12=-8231911. 6-10=-1196f706, 7-10=-3731512 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.0psh h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate gdp DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=219, 12=553. 8=248. 7) This truss is designed for a creep factor of 1.50, which is used to calculate the Vert(CT) deflection per ANSIfrPI 1. The building designer shall verify that this parameter fits with the intended use of this component. LOAD CASE(S) Standard 6+*q'Ikxn+MN�mv m�4l ritln14f5FYIlUj®31.NR1('KAA[LIRIG�-61a')URFf3'3lII'bL i,ir6YyPv�mb��mvoM11 4vtt6,.gIR::Wm4Nyl.Imb RILWmn Lm4se mnivM+rz, 9etlbmin.y Wl,rvvem l'n+tls,almmlmnkwt4rL,uem1,[,p.ep. fvaq 6r.,r}ebnwgmo,peanam,vrvtlbntlniwe,q.egpvy.melbml plb�y�l tyml.mmomG.n ql vtH.nwMnufyumwvwt:k) gnthony T. Tomb. 111, P.E. d,utlNrimrbgklfiq mmpvbGnlpAm,b4vsi„bnd r]mmbNgpnla, m m gmlKm RmlmbmhvA'�FvJrRL m9r^4tlm0G+4mmN tlminntl6g16; m ®NMn,dhWpJAbmnrmi:rytl 380083 I hHxypnrngfRv,M1rL.nWMvmi[OdlLrmermlpt9m,R0�pJYgf.lmvf[yias.'vflv�LL'I,pk,blFivdYamMPmlb pe9pJm lRl6l bngaif:atnlgnl14 ibnpe.lmtM4M1ival rm,rMCYn,w< 4451 St. Uxle Blvd. r3e+b mamlir6fmrp,n,mvmoghmA*nmNrctblmsLu'm[yarblGfbl4Y,pMgm,vinsfic+[,ryrEo14G4q W'q'hJv!IkuvrnrdmlxlM1l. � Fort frlene,FL 34946 GppipbDlGI4A�1IvdLessn-Amlvepi.ivmlv01,P8 Rpmdseievddivlvwm,uv.plmmisprvlTuehffiemdudveapmmisum6av41 kdlmm�lv6evpt.lemlvlG, p.l. Job Truss Truss Type CRYPN RENAR MORN INGSIDE WRMSCMBK15X10 TOLE HIP SUPPORTED GABLE 1 1 A0118571 Jab Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altmss.com Run: 8.210 s May 18 2018 Print 8.210 s May 18 2018 MTek Industries, Inc Wed Aug 29 16:28:47 2018 Page 1 ID:Id_OOXyyT61Bi_TXoljwHHzefvK-vdUtY,OJn7gDxfgmhVvVl7FjvXKxbiVC Wgt tyiyuE t-4-0 77-0-12 26-11-4 32-2-8 1 38_-0-0 '1 11-0-12 15.10-8 5-3-4 S-9A 5.6 = 5x6 = 31 30 29 28 27 26 25 24 23 22 21 20 19 3x4 = 3x6 = 3x6 = 24-9-8 126-11- 38-0-0 24-M 2-1-12 11-0-12 Dead Load Defl. =1/8 in Plate Offsets (X Y)— I7:0-3-00-2-01 rl4:0-M.0-2-01 119:0-3-0 0.3-01 LOADING(psf) SPACING- 2-M CSI. DEFL. in floc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.59 Vert(LL) 0.47 16-18 >379 360 MT20 2441190 TCOL 7.0 Lumber DOL 1.25 BC 0.48 Vert(CT) -0.36 16-18 >492 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.54 Horz(CT) 0.01 19 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix-SH Weight: 235 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except: 10-0-0 oc bracing: 18-19 8-3-13 oc bracing; 16-18. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. Al bearings 23-M except (jt=length) 16=0-7-10. (Ib) - Max Horz 2=102(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 2, 21. 22, 23, 25, 26, 27, 28, 29 except 19=-381(LC 8), 30=-116(LC 12), 16=-288(LC 8) Max Grav All reactions 250 lb or less atjoint(s) 2, 21, 22, 23, 25, 26, 27, 28, 29, 30, 31 except 19=681(LC 24), 16=593(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 14-15=335/528,15-16=-6611799 BOTCHORD 29-30=-150/382,28-29=-1501382, 27-28=-150/382, 26-27=-149/380, 25-26=-149/380, 24-25=-149/380, 23-24=-149/380, 22-23=-149/380, 21-22=-149/380, 20-21=149/3BO, 19-20=149/380, 16-18=-5971551 WEBS 14-19=-5941823, 14-18=-677/471, WEBS 14-19=594/823, 14-18=-677/471, 15-18=363/528,3-30=-116/252 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCOL=4.2psf; BCDL=5.Opsf, h=13ft; Cal. II; Ecp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Tmss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water pending. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Plates checked for a plus or minus 0 degree rotation about its center. 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live lead nonconcument with any other live loads. 9)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 21, 22, 23, 25, 26. 27, 28, 29 except Qt=lb) 19=381, 30=116, 16=288. 11) This truss is designed for a creep factor of 1.50, which is used to calculate the Vert(CT) deflection per ANSUTPI 1. The building designer shall verify that this parameter fits with the intended use of this component. LOAD CASE(S) Standard tlmy.rmrmm{LYn�k,$-1719faW$(!^1!fttirWfi,vstterarontr{1g.(Im11}uunnW.m'6n in8hrppnmmrd.n,nb,imrm,ytrrr^1C¢€,'mIx14IL1mMRrttesne AmlMrw. ¢huwmr 4d.br�0.ra. WI,Imbr::rtlr11rM440.':IrWl brinulm4`+�nPr.1M1:t�lrPdnbuimgi3r,>zunmepmetlb{dnwivpe9nrP ^bbbvptl4vthGmiryCtlm4l rY.,eIeIM1LhMgrnm{p4Egaet'.sx.W4n Anthony LTombo III, P.E. mlmrtlbrM,M1u1&hie4mPuWld4[.:.bG.w',wErdATrlu44'kq%rt4.h4x6tlbKOroIm4W WfA�WAI.IYOlmtltlbf:pvlmihYmY4lmtNhi4Nl m4a YJ'6umlYrOlJepPrmP'�KSd �80083 41d41M1upolmh.Nen,tl Kmtr R4Mtr(mafdp,brtl44xq 1apulH, Yrss Ptpkrbtl; IRW1K1mrM,vJbprtlplm nVl heronsp,tiWrelNnibiw &:4v,tm,quplryw MNnWlt.e.ahr 44515r. LVje Blvd. MmW HMIrr[WtlpMgm:aOgi/gpb,balal bLmhrgtq.neutmlwgmvp.®andN,e[q.vrrlrpwes uwu4,�Im.,nntld:iM1L � Fort Plwe, FL 34946 fv MO7!@kl WvJimuY W! LlvmlviRLE. Ie ivdrmxdlbaducmm,iem Brm,is v!iliNx01ev18ea9ev ,invlvm111vdLnusAvRv ffexly Pl,r1 _ Pdr vrl V f C f°°" C Job truss Truss Type DN PlyRENARMORNINGSIDE WRMSCMB3L15X10 B01GE COMMON SUPPORTED GAB 1 1 A0118572 Job Reference (optional) n-i Rom I russes, ron vierce, FL mu iti, oesignQalbuss.com Run: 8.210 s May 18 2018 Print: 8210 s May 18 2018 MiTek Industries, Ina Wed Aug 29 15:28:48 2018 4.4 = 1 3x4 = 14 13 12 11 10 3x4 = 2-" 12-" LOADING(psf) SPACING- 2-041 CS1. DEFL. in (loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.01 9 n1r 90 MT20 244/190 TCDL 7.0 Lumber DOL 125 BC 0.09 Vert(CT) -0.01 9 rur 80 BCLL 0.0 ' Rep Stress Incr YES WB 0.05 Horz(CT) 0.00 8 n/a nfa BCDL 10.0 Code FBC2017/TPI2014 Matrix-SH Wind(L-) 0.01 9 n/r 120 Weight: 56 lb FT=10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 OTHERS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. All bearings 12-4-0. (III) - Max Horz 2=-62(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 2, 8,13,14,11, 10 Max Grav All reactions 250 lb or less at joint(s) 2, 8,12,13,14,11, 10 FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown- NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSIfTPI 1. 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcunent with any other live loads. 8)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift at joint(s) 2, 8, 13, 14, 11, 10. 10) This truss is designed for a creep factor of 1.50, which is used to calculate the VerI CT) deflection per ANSIrfPI 1. The building designer shall verify that this parameter fits with the intended use of this component LOAD CASE(S) Standard l Fina.nm.v.prm aucnnmof>ale}k'v�IP�sImP�noanc.flaraiw�lnm�errsa ba;xvl�{.Ittlem.w,ImtMo-,.q;:smmmNFle�I,arLremmnw„K mmsl.,iva4 bro,m WidixfMYb VAI MhM1 vbeYl6elm{boyrgv„tp 1Ro�IR+�IN,N�gI`]T� v�tPo�tiblMalA �9 ivy'Ybhpibgp:m,lPl•bR-0,F.vbelf.@loWnm@41sIS1uL:a{fa'dsry Anthony T. Twb01II, P.E. ' tl .,dN{Im h.rleq bnynNgdbr.�bP.wtr2x4,pa SWly9t p,hbvercdb9f,paof elbadM#yuAolPH.hgr,MdblGMgbetlnAfo l�.n,NyghvNimyr.eh+m�Ik�q JAMw amiJ.ti,t .180083 4HgMtynd(rNvb NeY+NMaLltltlbrmtlptiv,YblXq(ryseLk{p ML11V:Y,IF'llol&Iv„2rtm1Yl�Ilel�{plhlutrru�.eCwdNndM1ri+u F.{n,'m54y41»di ttivdYve,sn't 44515t Lucie Blvd. 4i.edI h11,Whnallr ileMMMPr(TL,ultipfquah171M14xgb lm 4ue tqa, dq WEq a,getialb mnldd h'A I. • FOR Pierce, FL 34946 [eppilb020®l01141 P<1l I1hnrss�4neor LlomleN, 1.! Iryd �wARit/enmm,ieelylennNotilaedalaNOe nmeo ln®svwheml l hd Lesus�AaBeq IL¢Eh IB,Pt. Job Truss Truss Type Ory Pry RENARMORNINGSIDE A0118573 WRMSCMB3L15X10 B02 COMMON 3 1 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946. design@altruss.com 31 Run: 8.210 s May 18 2018 Pont 8.210 s May 18 ZU18 MI I eK Ineusines, Inc, Wed AUg 29 1b:28:48 2U18 4x4 = 3x4 = 1.Sx4 II 3X4 = la ' 6-2-0 6-2-0 LOADING(psf) SPACING- 2-M CSI. DEFL. in (Idc) Well Ud PLATES GRIP TCLL 20.0 Plate Gdp DOL 1.25 TC 0.41 Vert(LL) 0.05 6-12 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.40 Vert(CT) -0.06 6-9 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.11 Horz(CT) 0.01 4 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix-MSH Weight: 48 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. (lb/size) 2 = 53210-7-10 (min. 0-1-8) 4 = 53210-7-10 (min.0-1-8) Max Horz 2 = -62(LC 10) Max Uplift 2 = -144(LC 12) 4 = -144(LC 13) Max Grev 2 = 532(LC 1) 4 = 532(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-632/420, 34=6321420 BOTCHORD 2.6=-201/508,4-6=-201/508 WEBS 3-6=-151282 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcumenl with any other live loads. 4) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except 0t--lb) 2=144, 4=144. 6) This truss is designed for a creep factor of 1.50, which is used to calculate the Vert(CT) deflection per ANSIIfPI 1. The building designer shall verify that this parameter fits with the intended use of this component. LOAD CASE(S) Standard hvQq'hwlrrlHnnarh'llm.k,Otu.TwpF,—lu,tq@Il 9m lws w. hne QYmv Wdnhl[i,Mr 3.'. Yn, Irtll Ylpp,ahm Nml NnnN�Lw Ml�hngpR,dhl,4odul.t, 0"r,r, njNu'Nu,. vepinvONNnh N4pt.Nni?FL 1bL nnnpnxvYda)usngsdtli4d nYWA n,ImsYOplgseQa.yn2rylww" JwmOlnpo�q pn)nonyT 111, P.E. RLNX M NIxIwl"atalnW.%"dON.®6h "-d.nnk,hrvrbhn enhmpntlegtlhAm.btlndsrbRMapfvhW6lM�.ahmltlhl4hCalh4dA 9,deNIA1.n,7inQiM1l40atl n.kllw,IblmvMf9t!'er ¢9sh�tadYtlgJfYd"kma41Q t80083 80083 hM'1gMpeelr6 ww'wm�auo 44518[. WCiC Blvd. sle.hlfw(IpYam9rd,MhrM1rlhtllMn YiI,Q. RImspQxfgm,6lClhhigPnA.elmslietl[>MwQvl Yaq ingyulhmneldNblxl. Fonpierce, FL 34946 (e Ei®7110b1Ioollnaes-Ahilhh L(omho llh/1. ¢e mdeaiead16illemnem,inh Imm,n mEiEiledx'uAomMe ranee <mililotllitln A -I ledLhvo vrva Aa4en I.huWJ J. Y P 9 1 1 r _ Job truss Truss Type y Ply RENAR MORNINGSIDE WRMSCM83L15X10 BO3 COMMON ri, 1 A0118574 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@aitruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries. Inc. Wed Aug 29 15:28:49 2018 Page 1 ID:ld_OOXyyT61Bi TXoliwHHzetvK-sOcezO2ZIJNOSFpYy3jz_wgOSXdjoywt4zW7n5myiyuC -1-4-0 6-2-0 11-11-14 6-2-0 5-9-14 4x4 = 6.00 F12 4 �1 2 1 r r 5 1.6x4 II 3x4 = 3x4 = 6-2-0 11-11-14 6-2-0 5-9-14 Plate Offsets (X,Y}- [4:0-0-0,0-0-10] LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (Inc) Ildell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.41 Vert(L-) -0.05 5-11 >999 360 MT20 244/190 TCDL_ 7.0 Lumber DOL 1.25 BC 0.37 Vert(CT) -0.07 5-11 >999 240 BCLL 0.0 Rep Stress Incr YES INS 0.10 Horz(CT) 0.01 4 n/a n/a ' BCDL 10.0 Code FBC20171TP12014 Matrix-MSH Weight: 45 lb FT=10% LUMBER - TOP CHORD 2x4 SP No.2 SOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installa8on Guide. REACTIONS. (lb/size) 4 = 43910-3-8 (min. 0-1-8) 2 = 524/0-7-10 (min.0-1-8) Max Ho¢ 2 = 73(LC 12) Max Uplift 4 = -103(LC 13) 2 = -143(LC 12) Max Gmv 4 = 439(LC 1) 2 = 524(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-607/424, 34=610/425 BOTCHORD 2.5=-261/485,4-5=-261/485 WEBS 3-5=-16/269 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsh, h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrenl with any other live loads. 4)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at --lb) 4=103, 2=143. 6) This truss is designed for a creep factor of 1.50, which is used to calculate the Vert(CT) deflection per ANSIrFPI 1. The building designer shall verify that this parameter fits with the intended use of this component LOAD CASE(S) Standard rm,:q mmm,get m.b urx=nma01ua1nsuloeuumrnlmaxFmruurrr,afra. bh�hn=e:na:,tl,m,.mun,mee,.,a(rtzemrmli.l.aar>_le sm-m ,e,:. wa„mmn.,dr Nlnuvem,rTnWh.nbbnBmF•WL nvNuumPt,pape.!pm(4FMmav gRemPn®,vmp dhPviumwea,f mgvwuerYnpPam,gvt.Irmml.mIDo,[{.amnt It fmugrn¢MgMenuaaYl Anthony T. Tomba Ill, P.E. m,udkilmtmmlydt+l mmin::1FT 16mm mOmlKattl,Pamm Mxigpnry,v b ntlb&',mS.dmm41ay3y MEMal.m9andd61o4dwgtlrvdbimskLmllnri nR inM.d Mq JfYhrt`Iv*d�^d :30083 mmtryM(eoifwmu W a5tlarxb11414h1im,m11.a4xtdm4tlmghaPaf4ghkmx 2VpIMMNRWLIIm,dsawbpmtlprsa llFlhL,N,nlrmJfmol m4,imLn,puPn.l.n, Mphpnnll ,ra,Anx nMs 44515t. Blvd.494 �bnmlTW In6smryxtm„i�ghalvn bdrci hlnunuaf4sv41E166YgWmpv,,vimlf1,1a3nwfgMfq nq«admmvenlSmlmlM1l. � For[ Pierce, FL 74946 , FIL 6pyi,MO)OIEAI lealinws-AmlvryLivmlJILLF. IvpntvaimdlEn Oxooem,mvglmm,i,ploL3itedvi6entde rnrtnpemv,inhemAI lvolLnsso-leulwyl.ivmlolp, Y.L Job Truss Type Oty RENARMORNINGSIDE WRMSCMB3L15X10 �Truss B04 MONOPITCH 1 [[Y 1 A0118575 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.00m Run: 8.210a May 182018 Print: 8.210 s May 18 1.8x4 II 4 3.4 = 1.5x4 II 4.4 = Wed Aug 29 15:28:49 2018 LOADING(psf) SPACING- 2-M CSI. DEFL. in floc) I/deft Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.46 Vert(L-) 0.05 6-9 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.37 Vert(CT) -0.06 6-9 >999 240 BCLL 0.0 ' Rep Stress Ina YES WB 0.45 Horz(CT) -0.01 5 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Matrix-MSH Weight: 62lb FT=10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-&B oc pudins, except end verticals. BOTCHORD Rigid ceiling directly applied or 8-1-12 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 51810-7-10 (min. 0-1-8) 5 = 434/0-3-8 (min. 0-1-8) Max Horz 2 = 264(LC 12) Max Uplift 2 = -107(LC 12) 5 = -191(LC 12) Max Grav 2 = 518(LC 1) 5 = 434(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=613/195 BOTCHORD 2-6=-486/500, 5-6=486/500 WEBS 3-6=0/273, 3-5=-558/542 NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 lost bottom chord live load nonconcument with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at --lb) 2=107, 5=191. 5) This truss is designed for a creep factor of 1.50. which is used to calculate the Vert(CT) deflection per ANSIr PI 1. The building designer shall verify that this parameter fits with the intended use of this component. LOAD CASE(S) Standard rulq.nxumrylymb m'All]4i nasnFmwTeplltRmSi('tnn[4lonulfnmt+-nun:wFrrm.Inryhtlpre,abmMMumnnrl n.On}nhmy(IG;dmwb.11 lmbP rLw aatl+e Otlm@m Wtl mmo,.y wiammblvs mnmmmnonh.nA nnr.uPwrq.e Al.nryupa mwn ,nrrpemvn.nps.tlmprlmm...-ry pmwryrmp.,xm:.yrtrrvnyna.mmowr aar+l nrt pru.p mgmemn,waiul Anthony T. Tombo Ill, P.E. 4rvtlbbim mgmwonminpnbJerlmOne mnm.rmmdeefebwlM1ghrber trYentlmECmT,Mmbdb'tn'nreilM bpinrntlmMdmmtlwnmimthtlry A*F9 gnm9mudhv+IrFLbrb p.Yryd r80083 hbigMR'tlfRmk l9anrPY.mIWdmPvnolRltlTVAmwb9Gpe/1LrRNrmirv;.'1'urJdllllletl9llmrhwlYRmi Pltl.lnlnYe.m%rT 119rrdbnYlUlnfneN.Im.dfFH'°e.fl �m.hae..4n I 4451 St. Lucie Blvd.— rleeu hAd171WmrJeelryYbnmq„®IwnmYul�inuhup[4'mrtheftm Wigdvin,ei:nvlicealquetlaibJfq wqm WbmnnldMeI1LL � Fort Pierce, FL 34946 4 01®701d4i UelhasmsAmla LlomlelP, PJ. Le mdeaiwolaislomneel,ie lerm,is:ol2Aedridendeerime emissioeheo4l &olbnmsAeAm LlemlolO,RL_ vv4 w v w v v r _ Job Ory WRMSCMB3L15X1O �Tmss BO4GE �Truss`fype GABLE 1 �Ply 1 �RENARMORNINGSIDE AO118576 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@attmss.com Run: 8.210s Mav 182018 Print 8.210 s Mav 182018 MTek 1.Sx4 II 4 3.4 = 1.5x4 II 5.6 = Inc Wed Aua 2915:28:50 2018 LOADING(psf) SPACING- 24O-0 CSI. DEFL. in (foe) Vdefi L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC OAS Vert(LL) 0.05 6-13 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.37 Vert(CT) -0.06 6-13 >999 240 BCLL 0.0 ' Rep Stress Ina YES WB 0.44 Horz(CT) -0.01 5 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix-MSH Weight: 70lb FT =10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. BOTCHORD Rigid ceiling directly applied or 8-1-12 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation aide. REACTIONS. (lb/size) 5 = 434/0-3-8 (min. 0-1-8) 2 = 518/0-7-10 (min. 0-1-8) Max Horz 2 = 264(LC 12) Max Uplift 5 = -191(LC 12) 2 = -107(LC 12) Max Grav 5 = 434(LC 1) .. 2 = 518(LC 1) FORCES. fib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-613/195 BOT CHORD 2-6=-486I500, 5-6=486/500 WEBS 3-6=0/273, 3-5=-5581542 NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/rPI 1. 3) Gable studs spaced at 2-0-0 oc. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcunent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom Uord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (t=lb) 5=191, 2=107. 7) This truss is designed for a creep factor of 1.50, which is used to calculate the Vert(CT) deflection per ANSI/TPI 1. The building designer shall verify that this parameter fits with the intended use of this component. _ LOAD CASE(S) Standard - - : nPobannil n4l ntilY.fit(ipinjHllYN16lC#.iAG0f410YjxfirjlOR.GN'ba l�htlpryoamnheaWnatll MpYnW(nP,uWimgllm4nrLWa 4a+knm WmMmhM 4TY.uy Witvearptb Wh IbtriYJYMr4LhYM.buphraet� IndrbpYajmW g1W�prmnvv}vYWpdnvmlmu-yrywNWY Mr Atb,r/1 t4�'3IwbR9ah.,lel!N-Mtapnveryp.WrymGb vetlRl Andlony T. Tanbo 11I, P.E. n4,dw lrnby Wq 4N rn,rmwmoho .Won,,,+vedmmv W 114 DOW, q hmOmIMOMNaf W%Wl.Ynpnh ei DO% pxmlahloo mlmhX, am 1OO.W."Wp, S WIPbaWw,"e YWmp.'4' a a80083 hlzYapMprvlIC,N lY mmmYW lop W hrxbnui'mm, am PEW hmardw, Yvtl ,T.firtllNNIr 1YN3111neNs:vl4pmtlpb lMbSntbmpaifa,i4Hn out.., h.Imr onrrhpvu rlml I 4451 St. Wde Blvd. . ,lavW raSWln 6fm,1,45 Ymmrha Mm WYn(lhlnv:cWlTvunrplbtHYa1&.ye,vu s!reabpwaerMbp 04ja*,mmm&AOMl. Fon Piu.,R 34946 (appipEi01011AIIrelLusn-bAogLloeAJO,❑. hpMeaioYolAnlomvem,ie4xl isp�olT4rd YiAem Ae mineepe�suw6evbl lydUaus AeAmpl.lomlom,?.L Job Truss rrussrype aty Ply RENARMORNINGSIDE WRMSCMB3L15X10 C01G GABLE 1 d A0118577 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 Mi-Tek Industries, Inc. Wed Aug 29 15:28:51 2018 4x4 = 2-014 1.5141,9,5, 9$n 4x6 = na] 194-n 1d14 0 7 )-]-4 7-7-2 2014 039 LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (too) I/deb L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.47 Vert(LL) -0.13 12-15 >999 360 MT20 2441190 TCDL 7.0 Lumber OOL 1.25 BC 0.90 Vert(CT) -0.23 12-15 >964 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.87 Horz(CT) 0.02 12 We We BCDL 10.0 Code FBC2017/TP12014 Matrix-SH Weight:108 Ib FT =10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 5-2-2 oc pudins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 16, 17, 18, 20, 21 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 777/0-8-0 (min. 0-1-8) 12 = 777/0-8-0 (min. 0-1-8) Max Horz 2 = -90(LC 6) Max Uplift 2 = -160(LC 8) 12 — -160(LC 9) Max Grav 2 = 777(LC 1) 12 = 777(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-1176/244, 34=-7961140, 4-5=7541140, 5-6=-7311159, 6-7=-722/185, 7-8=722/187, 8-9=-7311161, 9-10=-754/141, 10-11=-796/141, 11-12=-11761241 BOTCHORD 2-23=184/1053, 23-24=-184/1053, 24-25=-184/1053, 25-26=-184/1053, 15-26=-184/1053, 14-15=184/1053, 14-27=-18411053, 27-28=184/1053, 28-29=184/1053. 29-30=18411053, 12-30=184/1053 WEBS 7-16=421430, 3-19=410/139, WEBS 7-16=42/430, 3-19=410/139, 18-19= 4111139,17-18=-411/139, 16-17=-405/134, 16-20=403/132, 20-21=4111139, 21-22=4111139, 11-22=-409I137.15-16=0/395 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult-160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. II; Exp B; End., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/iPI 1. 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrenl with any other live loads. 7)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 2=160. 12=160. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 160 lb down and 73 lb up at 2-0-0, and 160 Ib down and 73 lb up at 17-34 on top chord, and 77lb down and 35 Ito up at 2-M. 17 lb down and 1 Ito up at 4-0-12, 17 lb down and 1 lb up at 6-0-12, 17 lb down and 1 lb up at 8-0-12, 171b down and 1 Ib up at 9-8-0, 17 Ib down and 1 Ito up at 11-3-4, 171la down and 1 lb up at 13-3-4, and 17 lb down and 1 lb up at 15-0-4, and 77 Ib down and 35lb up at 17-34 on bottom chord. The desigNselection of such connection device(s) is the responsibility of others. 10) This truss is designed for a creep factor of 1.50, which is used to calculate the Vert(CT) defleebon per ANSI/TPI 1. The building designer shall verify that this parameter fits with the intended use of this component. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase-1.25 Uniform Loads (plf) Vert 1-7=54, 7-13=54, 2-12=20 Concentrated Loads (lb) Vert, 15=1(B)23=3(B)24=1(B)25=1(B)26=1(B) 27=1 (B) 28=1 (B) 29=1 (B) 30=3(B) - d•11 ntflrinjlNlfl n19u0L0nPFAlImmIPY(dN1111[;,i.1fm'1 m. leAr6JrpmamdMdnndl IMp1 qnr*: rahIMlLIsbRlLldn 9. fM1 hO�n,Mn WI nnv.wl Artlqdm,nrrlYl nWu Anthony T. Tombo 111, P.E. eandb4 tryb�=ged,W^v10!IdO.,e dGm'„Am,l Fardkllig6„pw 'vuMnah R.4R VIbad6Y9,W vtR.1 ingmdtlM1lEOedskl alleimval&ilairicz,! aMmodhratddbh 'IaAtntl z 30083 d dYa1MR,44tna. iirn,o.arbIDO.adrim,dpatl tln hvMrmevd's,gaom 'IX4;INdJhnINYtlmnMmlLlvndfa 1KI m. L,nlnil Islhnd4l bapml. A,efrpvvlr Ya6mr.vn 44515t. Lucie Blvd. ,lemu Id,dli6mm r7edmbmaq Ndlmxtda5LL rtrmvuua!q.unnreldulq[r4e,ermvfteafgameerwfy m,o.8n,ltmmnlamaml. Fort Pierce, FL 34946 0 6102616 AI ladimssvl Aveav Llvmbv laPLb mdvaiavvlllislvmmem,ivn im s idi3nedriRvNeevnna v,miuivvhvmAItvdlnem-Amhvn LivmlvN,LL. _ - Pnil I 7 I ryi P P r Job Truss Truss Type Dry Ply WRMSCMB3L15X10 CO2 COMMON 2 1 �RENARMORNJNGSIDE A0118578 Job Reference (optional) n. A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 414 = 4x4 = 5x8 = 40 = LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) Udefl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.44 Ved(LL) -0.14 8-14 >999 360 TCDL 7.0 Lumber DOL 125 BC 0.85 Vert(CT) -0.22 8-14 >999 240 BCLL 0.0 Rep Stress Inv YES WB 0.21 Harz(CT) 0.02 6 n/a n/a BCDL 10.0 Code FBC2017/fP12014 Matrix-MSH LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Stmctural wood sheathing directly applied or 5-0-10 oc purtins. BOTCHORD Rigid ceiling directly applied or 743-8 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 79110-7-10 (min. 0-1-8) 6 = 79110-7-10 (min. 0-1-8) Max Horz 2 = -90(LC 10) Max Uplift 2 = -205(LC 12) 6 = -205(LC 13) Max Grav 2 = 791(LC 1) 6 = 791(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - Al forces 250 (lb) or less except when shown. TOPCHORD 2-3=11891788, 3-0=-898/581, 4-5=-898/581, 5-6=1189/788 BOTCHORD 2-8=-562/1042, 6-8=-574/1042 WEBS 4-8=-264/553, 5-8=-347/387, 3-8=-347/387 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsh h=13ft; Cat. II; Exp B; End., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed fora 10.0 psf bottom chord live load nonconcument with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on.the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift at joint(s) except Ot=m) 2=205, 6=205. 6) This truss is designed for a veep factor of 1.50, which is used to calculate the Vert(CT) deflection per ANSI/TPI 1. The building designer shall verify that this parameter fits with the intended use of this component. LOAD CASE(S) Standard 29 Dead Load Defl. =1/16 in IY 0 PLATES GRIP MT20 244/190 Weight: 88lb FT=10% levbRtlltlenlSbn= BlmeYnn OLtlnMld,n} raWshn+Itts" iaJLR'Irt i,rL�6du NtenmN,dd�tvvml Yµ,FVdit xatY,mnegO�RYbmlM1bmhYNb Alt 4q Yupfgaep SLeitlrbpnv{bb gPID,tpn,LS nvpmlbrLnNelrgnbrmpubf%M1MI PtlStsjelrctilz¢1nMROhI(Wv1M.3L {,nuo/.hl.b9 m+�tlhL "W&M13lRi6jf88rL Aso t Qt.r glossj6isots sot AnNony T. TanbO III, V.E. 4mtldb rm MR1A1W Mmp.YW tlMOm, MC•nteiNtlyefv6bM1q Onrya M'onntlMuf.Ml:ddebui laxgn4dlFLR gmLtlbnComM1RmdNimt YM16gtr[uyn+v.mvNwdhryJiYM1mfasr!>tl Y80083 MI+YarPn'r=dfRhsr ilu33wWYblWdhpevutmf ptldm�dYMMb°Inm Wnarenn NLi MbWpIR IWInIMvmlSipNN Inlhly s!rtgewbrnslben/41 bynl:ntMm bree llmsrrnit"en.N1t I 4451$L Lucie Blvd, ISMuldvtlln Lsmgxlw LnraghdllxlMMLd I4lmlav�Lgmmh101411snlagw, M.t.rnafqumimfdLb N9Yais v,n LdMlIRI. � Fort Pierce. FL 34948 4 li®1014bl laallnsse�kidoe LlvmEdO,PI, Pr MamaLoldildemoed,ivvr Imm,is �olThdhiilondevnml imiiwrheakllmlhaln-IVEw i.lad! P.1. Job ` Truss Type PN RENAR MORN INGSIDE �Tnuss WRMSCMB3L15X10 CO3 COMMON �Qty 1 1 A0118579 Jab Reference optional) o A-1 Roof Trusses, Fort Pierce, FL 34946, design@altmss.com Run: 8.210 s May 18 2018 Print: 8.210 s 4x4 = 18 2018 MTek Industries, Inc. Wed Auq 29 15:28:52 2018 44 = 5.8 = 40 = LOADING(psf) SPACING- 2-M TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 ' Rep Stress Ina YES BCDL 10.0 Code FBC2017rrP12014 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 5-1-0 oc purins. BOT CHORD Rigid ceiling directly applied or 7-4-14 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 6 = 70010-3-8 (min. 0-1-8) 2 = 78110-7-10 (min. 0-1-8) Max Horz 2 = 99(LC 12) Max Uplift 6 = -165(LC 13) 2 = -204(LC 12) Max Grav 6 = 700(LC 1) 2 = 781(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-11641783. 3-4=-873/576, 4-5=-870/575, 5-6=1145r768 BOT CHORD 2a=-619r1021, 6-7=-600/981 WEBS 4-7=-258/527, 5-7=-311 /365, 3-7=-348/387 NOTES- 1) Unbalanced roof live loads have been considered for this design. CSI. DEFL. in (loc) Well Ud TC 0.46 Vert(LL) -0.14 7-13 >999 360 BC 0.82 Vert(CT) -0.22 7-13 >999 240 WB 0.20 Hom(CT) 0.02 6 nla n/a Matrix-MSH 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. II; Exp 8; Encl.. GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except 6[=1b) 6=165, 2=204. 6) This truss is designed for a creep factor of 1.50, which is used to calculate the Vert(CT) deflection per ANSIrI-PI 1. The building designer shall verify that this parameter fits with the intended use of this component. LOAD CASE(S) Standard Dead Load Dell. =1116 in 6a PLATES GRIP MT20 244I190 Weight: 84 lb FT=10% e+.n.mvn,,,�M•:n..mrmesnma(wuTonr:mmlm,anentmru(an}uoceawrl...aryanw•,=tl"sm.ddn.nnm,an�a..ypu,wmin.M1t.Yarlu+,,,YmYeom.umn,n«.mond,e,mo,.} — nmmurd,a0eadmmnJUM.aL Yruuwgry..nr.y.aqup,+,dwngm:,pnmlomlmtlmr�d+v.dn'+v*r�rvvwanmminpamspt:.l:tand„dmomnwevu.dapnveryaxa„mnv.wa�ot Anthony T. Tombo 111, P.E. ' ndu,tlY,Ira:Ygril[grin:e:P'��^ItldO.re.mO.attrlevd,}fubY�Wryu�,+n:mrntltr6,m RdmMidYAMeellFl.11rq>,Ktlmmvdamll n,tlmlmtnl6gl-FTynry.im9maelh.gJdSbuyau'.Ind 380083 mhRgn:revert,u.n.nmr.mrtmadranmfm3m:tlm4N9rpsxNnlnnme:W7WmtlNPrevu.,nnnnYpndptu lttlaa:brtgmirblmanrnl:n.nvHvTtn,vnv6levsirm:mekee-ia 44515L Lucie Blvd. - S,Mur4odlpanm,FM.muwogll,Ormlm,hH relnun:,nryuv M1lClmnlaYlge,,dm:6nt+fgamd W MB9 agBadMou,nWW bRn' Fort Pierce, FL 34946 U2Pn 11V20166Itvdbvnetl�nv+ Llvn6e01,Pi to mdvaiavvlilislvmruvl,io+ Ivm,is :aliEded vitleYMearineo e:miniee6vmkl levlbnuv�Aebw 1.IvmlvlO,Lf. Y P 9 P 1 Y Job Truss TC Truss Type MORNINGSIDE AO118580 WRMSCMB3L15X10 4GE GABLE �Qty` 1 �PIY 1 �RENAR Job Reference (optional) A-1 Root Trusses, Fort Pierce, FL 34946, design@atbuss.mm Run:8.210 s May 182018 Prinb 8210 6.00 FIT 7x6 10 18 2018 MTek Industries, Inc. Wed Aug 29 15:28:52 2018 6v8 = 4x4 ,as7 2 ,8�� ,�z 2 „� 10A7 I &1S 0.13 6-7d 1 o<u Dead Load Dell. =1/81n Plate Offsets (X Y)— r5:0-2-0 0-0-121 17:0-1-00-1-81 r9:0-6-8 0-3-01 111:0-2-12 Edoel [13:0-1-10.0-0-12]I17:0-1-10 0-0-121 LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.63 Vert(LL) 0.15 8-9 >547 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.95 Vert(CT) -01A2 11-27 >533 240 BCLL 0.0' Rep Stress lncr YES WB 0.72 Horz(CT) -0.01 10 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix-MSH Weighl:1951b FT=10% LUMBER - TOP CHORD 2x4 SP N0.2 BOTCHORD 2x4 SP No.2 *Except' B3: 2x4 SP No.3 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 5-2-3 oc purifies. except end verticals. BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. MTek recommends that Stabilizers and required _ cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 0-3-8 except (jt=length) 2=0-7-10, 10=0-2-12. (Ib) - Max Horz 2= 294(LC 12) Max Uplift All uplift 100 lb or less atjoint(s) except 2=-168(LC 12). 8=-138(LC 8). 9=-002(LC 12) Max Grav All reactions 250 lb or less at joint(s) 10, 8 except 2=710(LC 1), 9=1105(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-917/499, 3-4=614/311, 4-5=-478/323, 5-6>166/367, 6-7=-154/355 BOTCHORD 2-11=709(789, 6-9=-586/481 WEBS 3-11=391/462, 5-11=01355. 9-11=-4211485, 5-9=-702/626, 7-9-390/481 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch right exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonwncurent with any other live loads. 7) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s)10. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 168 lb uplift at joint 2, 1381b uplift at joint 8 and 402 lb uplift at joint 9. 10) This truss is designed for a creep factor of 1.50, which is used to calculate the Vert(CT) deflection per ANSI/TPI 1. The building designer shall verify that this parameter fits with the intended use of this component. LOAD CASE(S) Standard Ge9'NmM¢16yma,n'Litltf mi0l-i111Rl4rallmgt(YnA[%(61MRr]';l[u4Y the lMYupp,aamdrtldrs¢o�InuLW 6e,e91m.'mM11M,.IwY 411W 'hekn Otlm6n Mi MIDU.¢Y 41n,mnlb WYwlbm,m¢Ndd fir,milrsrplgx}e il/ullhpmbmutl gNPmm,m mpstl6ptlw,moncornpvlJVlkmMPibrq[i[yMu4,Altmb.¢bmt'YKpwap,¢.Mlyule„�w,lal Anthony T. TonIbo 111, P.E. w ¢,tlAm4 ftq WAq-LL,ep,mutlLL4.m m4Mi,msemgm¢LLbBgn,ym ermutlhtlf,mb: to bmbYmlctle WlM.bmP, JtlLLIlONmtrllmtlmimcSim�IXgmy -mBm mlhnq JmMh pY.4e z80083 ' LLraYaipne¢Wfmtv,¢m,em�m,lWrtlhim�^+dl"Ie.�ebWMrWe,m LMrt4uwnG,p4tYllr,Ilnlllnn:Nn:vlNretlriat Pltlf¢tlmryakmnWMneml.ns0.vps.,"v,Mpppnsllm4mm,ne¢,¢Mt 4451 St. Lurie Blvd. 3em,if,tl11.0tl'm4'mmM,e¢m,IFAin¢mtl,d Mrmia }[q�brOlpMAai4q¢ ,.s.l�,l4+maerwy wuemu..�mnw.msm, � Fort Pierre, R 34946 G ri 110701AA1Iedlmue�Amlor L.Ioml, II1PT. le uilom.dlAndemmem,uov Im4ii mb3beenArmMrnnel e,m6mrhemb Pl1 1 P 1 P F IledUnsm-Aeew�er Llamle N, L[. Job Tnlss OIY PIY RENARMORNINGSIDE WRMSCMB3L15X10 COS �TrussType ROOF SPECIAL 1 1 AO118581 _ Job Reference o tional A-1 Roof Trusses. Fort Pierre. FL 34946. d esign@a1[mss.wm Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MTek Industries, Inc. Wed Aug 29 15:28:53 2018 Page 1 ID:Id_0OXyyT61Bi TXoljwHHzefvK-kns8o154NYugxs7JBuov9m70a8sukelytaz_EXyiyuB 1-0 5-34 12-103 19430 25114 1 544 7$13 &1-13 G714 6.00 Ill2 5x6 = 5 6 11 5x1o= 3.6110 4x4 = 9$13 1e-312 1"1,2 2i114 9-&13 9$15 0.1.6&]4 a414 Dead Load Dell. =1116 in Plate Offsets (X Y}- [4:0-2-8 0-3:M [5:0-1-12 0-0-141 [6:0-0-0 0-1-15]. [7:0-1-00-1-8] 110:0-2-12 0-3-01 r12:0-3-12,0-3-0] LOADING(psf) SPACING- 2-M CSI.TH FL. in (foe) I/deg L/d PLATES GRIP TCLL 20.0 Plate Gdp DOL 1.25 TC 0.60rt(LL) 0.09 8-9 >935 -360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.86rt(CT) -0.25 12-15 >907 24➢ BCLL 0.0 ' Rep Stress Ina YES WS 0.53rz(CT) 0.01 11 n/a We BCDL 10.0 Code FBC2017/TPI2014 Matrix-MSH Weight: 151 Ib FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP Nc.2'Except' 83: 2x4 SP Nc.3 WEBS 2x4 SP Nm3 BRACING - TOP CHORD Structural wood sheathing directly applied or 5- -4 oc pudins, except end verticals. BOT CHORD Rigid ceiling directly applied or6-0-0 oc bracing. WEBS 1 Row at midpt 10-12 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 0-3-8 except Qt=length) 2=0-7-10, 11=0-2-12. (lb) - Max Harz 2= 295(LC 12) Max Uplift All uplift 100 lb or less at joint(s) except 2=-175(LC 12), 11=380(LC 12). 8=150(LC 8), 9=-281(LC 9) Max Grav All reactions 250 lb or less at joint(s) except 2=741(LC 1), 11=701(LC 19), 8=261(LC 24). 9=679(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2.3=-1103/642. 34=7451367, 4-5=-87/309, 6-7=-1491282 BOTCHORD 2-12=-078t975, 10-11=-628/416, 5-10=-4471386 WEBS 3-12=-446/538, 4-12=0/368, 10-12=517/576, 4-10=6991616, 7-10=281/377 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vu1t=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch Fight exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 4)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 240-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 11. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 175 lb uplift at joint 2,380 lb uplift at joint 11, 150 lb uplift at joint 8 and 281 Ib uplift at joint 9. 7) This truss is designed for a creep factor of 1.50, which is used to calwlate the Vert(CT) deflection per ANSVfPI 1. The building designer shall verify that this parameter fits with the intended use of this component. LOAD CASES) Standard ..ml.rvne..yl,u..m•nloum�IDOCrruulms�:lunAmanemm�o.(mrr;un�,�;ulrl.c rl:elearpmsmdudnu.ml:,:!ewr®n4(mide.lm.n.l.l,rtrtld,�la!nbs,m. wmm..:u andue!lao.ut eldnmann:lflb,WbWm.Y�tld bllm!Itir`!FuW.slmqupnrim!!+nvlmrzPvmnvapxremPm!�la+!!'4aywlurybnlnnamnklm: trynluamemr,d'+1!,1. rlrespnnalunMyuums!md3Y Antony T. Tombo 111, P.E. dwdW rm$bmi a4Rrap:lb?dNr-.m emtcbddrx..6Wf9Wryn,.6Md dwlth v1.IMJlrfdp!,6WW,16prmddm XIWwIxndb l!ut"k.11, agcmnOd+WY.gdmb4mta ilf!d :e0683 ftu',mte J4G,[-"..'W n.%Mw. nW;w. dm W194ei°n" L .W..'NeeI1maWm:tlmllLP,vY".SKI b!Y.,nR Mn,!Wb3![LLn! Dr TA.' L'&Meflnul Acfie�m': I 4Lucie Blvd. 1ledu fihvinbdngedm."Ile rmnmv, @inn Sv.r4®!b R161fbllu4v ui+n SM. al.u! eandlq 0 coAbmnn dMilml. � Fort n Plerierrn, FL 34946 [.ppirll®IDIEAIIoe➢rvsles-AdEvvpLlomhv06PL1vpMadi..vllEnlemmm,ivvglmm,isplailEded.i%vml6e.nne.prniniwfi.m4�l lvddmsdr Ae�lv.rl,IemloAl,6[.-__ .. Job Truss Type City Pry a WRMSCMB3L75X70 �Truss CAComer Jack 8 1 �RENARMORNINGSIDE A0118582 Job Reference (optional)Ir A-1 lxoot I msses, Fort Pierce, FL 34946, design@albuss.mm Run: 8.210 s May 18 2018 Print 8.210 s May 18 2018 MiTek Industries, Inc. Wed Aug 29 15:28:53 2018 LOADING(psf) SPACING- 2' -0 CSL DEFL. in (loc) I/dell L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) 0.00 7 >999 360 TCDL 7.0 Lumber DOL 1.25. BC 0.03 Vert(CT) 0.00 7 >999 240 BCLL " 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 4 rue me BCDL 10.0 Code FSC2017/TPI2014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 0-11-11 oc pudins. BOTCHORD Rigid ceiling directly applied or 10-0-0 cc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation u[de. REACTIONS. (lb/size) 3 = -3/Mechanical 2 = 166/0-7-10 (min. 0-1-8) 4 = -16/Mechanical Max Hoe 2 = 42(LC 12) Max Uplift 3 = -3(LC 1) 2 = -70(LC 12) 4 = -16(LC 1) Max Grav 3 = 12(LC 8) 2 = 166(LC 1) 4 = 20(LC 8) FORCES. (Ib) Max. CompJMax. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psh BCDL=5.OpsF, h=13ft; Cat 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed; porch left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load noncencument with any other live loads. 3) n This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 3 lb uplift at joint 3, 70 lb uplift at joint 2 and 16 lb uplift at joint 4. 6) This truss is designed for a creep factor of 1.50, which is used to calculate the Vert(CT) deflection per ANSI/TPI 1. The building designer shall verify that this parameter fits with the intended use of this component. LOAD CASE(S) Standard b9 PLATES GRIP MT20 2441190 Weight: 6Ib FT=10% rY9rue.,gviminh'W nE'RIlig(SRlajanW tmarlxmltlaSiN(GIa)xMP.aiYf\rbe IM6WlonYmxY,dumamimienp6,.y11[:;druarl.inhnlEm>envmfenn. tMnmunuatlanrIDa.H Wlnaaehl}n nShWbMr➢nF�LL Iu1m�Mglgxpe.E hpeYMWngt®,rynytma¢�OMrYnundmeetl,lry•4M1Iry1M1hPtlhttjelm�t'r@IUMRe rt.nbrrll.9MPnuelnrmbyabec.u®1�E1 /lnthoy T. Twbo 111, P.E. ¢f,utltif lmt3, RlnRgbMmPrul5ydbOm,M1OMuI.rt•9,NaM4lFylnipr,ar,uMdh6,r0InlMhmlaYgMe NIM1I.1gPMir REd,nhYmtlMlmt�]6gblejiLgtn�nnnlMgJYYhnyn 3!atl 180083 nrYgrnyn wur.{Eu»Mea•MN4atlhP�i�MynnBrMo9MP�nlfnf neon:tlL.'WnllMtllglllloeMsmftymtlplm M14L:eunlmflm�nf6M1M4nidoptlmir,A41'mnllmsYatl,Ra.e1ss I 44515L Wfie Blvd. Reun IGtl11i64mgetl,p Ymaghtlllnn•Y,H rnNu3:}Egan LlElhhVaiingn,vinnficn[gex,dgldlq Nm a,ItnnxlLtltlRN. Foit Piom,R. 34946 Lppill10101E At Ixtinssm WkepLlomEtllE. H. Ieprdeaaeelnndomnem,ioeglnm.isploL3ned aitEemeevrinhpemndwhen A11ad1ususle0n.1. ]emlolA, P.L Job Truss Truss Type Qry Ply WRMSCMB3L15X10CJ3 Comer Jack 4bReterence(optienal_ [ENARMORNINGSIDE AO118583 A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MTek Industries, Inc. Wed Aug 29 15:28:54 2018 Plate Offsets (X,Y)- (2:0-4-0 0-0-41 LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(L-) 0.01 4-7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.12 Vert(CT) 0.01 4-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 We n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MP Weight: 12 lb FT=10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-11-11 oc puriins. BOT CHORD Rigid ceiling directly applied or 10-" oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 60/Mechanical 2 = 20110-7-10 (min. 0-1-8) 4 = 30/Mechanical Max Horz 2 = 82(LC 12) Max Uplift 3 = 43(LC 12) 2 = -72(LC 8) 4 = -27(LC 9) Max Grav 3 = 60(LC 1) 2 = 201(LC 1) 4 = 49(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-sewnd gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed; porch left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonwncurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 43lb uplift at joint 3, 72 Ib uplift at joint 2 and 27 lb uplift at joint 4. 6) This truss is designed for a creep factor of 1.50. which is used to calculate the Vert(CT) deflection per ANSI/TPI 1. The building designer shall verify that this parameter fits with the intended use of this component. LOAD CASE(S) Standard reu�.nnuavrgH.n•ua ral l VQFfl erZff[n Wel:rM1V1X�bumorj¢T]}1abT� Wrk>IMrkonr•r.s,netMrannMun,Wyrhnq{rt-.',Wblelerl.In4oux Mvnru�4'nnn Ytln+Au.vrYo-l.b,lUo,.7 -- 11II WieYmrnllr+k9kcrlbbnpbMN�L4rLrulogfrynb L.Srrv%LpMymutlnvlPp,ynm,vm,uutlbrtl�numrgnnpnNvulAarYdlnndbs.}rin:�l!puloblW.¢.Ne1M1l.bt �urvpr¢N9 ^z+ mJ Anthony T. TOm0111, P. bE. drud Mlm,bylrlgbh,nW'�.'tlbQ.rn.bP+virrA vtlrPnblaMy Wgx,abmrtntlbl4b Cmlb6dl.YrybYvilnl. P, gantltlb:aNwbtlrvtlblmtv,figr �mr�.4ibAmvnlMgYRB4¢gautiatl -180083 4W"Ml'^vlGGve.LUT WArbII0nlb6nnn114bgdMWLIrWaJYlllbnti.! 1'W'lJ%IRMflnv:,tlaeaUYnmtl Flm Alkaa:bm�Ht�nsl MYbin+p''Y.Im+MS01°ev11m,�YM,.T•t�tift I 4451 St Lu 61Vd. en.bwiwyruemyragnr.irsgrydM.Intlnt nrnvnv,.fgwtttfbru,ItnW vlm,SroaLpa,ewrkaq ar+�atl m+nnsa nrmi. Fort Puce, FL 34946 appipEi01014AIIATrissesd ifliny h.b.Iff'U. 8+p,odoaivv vlaisdvmnem,ivngtmv,isp,oL3ddriiheNWunnee pemisuvr6vnkl rvolLvvus kcfionrl.lt dol1V.L - Job Truss Dry Ply WRMSCM0131-15X10 D01 �TrussType HIP GIRDER 1 1 �RENARIVIORNINGSIDE A0118584 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@albuss.com 3x4 = Run: 8.210 s May 18 2018 Print: 8210 s May 18 2018 MiTek Industries, Ina Wed Aug 29 15:28:55 3.4 = R LOADING(psf) SPACING- 2-" CSI. DEFL- in (loc) Ildefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.72 Vert(LL) 0.11 7-8 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.52 Vert(CT) -0.10 7-8 >999 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.16 HOR(CT) 0.03 5 We n/a BCDL 10.0 Code FBC2017rrP12014 Matrix -MS Weight: 65 lb FT = 10 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD 24)-0 oc pudin (3-8-11 max.) (Switched from sheeted: Spacing > 2-0-0). BOTCHORD Rigid ceiling directly applied or 5-10-9 oc bracing. REACTIONS. (lb/size) 2 = 985/0-8-0 (min. 0-1-8) 5 = 985/0-841 (min. 0-1-8) Max Horz 2 = 53(LC 7) Max Uplift 2 = -592(LC 5) 5 = -592(LC 4) Max Grav 2 = 985(LC 1) 5 = 985(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1667/1089,3-15=-1464/1016, 15-16=1464/1016, 4-16=146411016, 4-5=-1668/1090 BOT CHORD 2-8=947/1444, 8-17=961/1463, 17-18>961/1463, 7-18=-961/1463, 5-7=-914/1444 WEBS 3-8=-241/420, 4-7=240/420 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.OpsF, h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) This truss has been designed for a 10.0 pat bottom chord live load nonconcument with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 592lb uplift at joint 2 and 592.Ito uplift atjoint 5. 7) Graphical pudin representation does not depict the size or the orientation of the pudin along the top and/or bottom chord. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)108 lb down and 144 lb up at 5-M, 58lb down and 86 It, up at 7-0-0, and 58 lb down and 86 Ib up at 8-0-0, and 108 lb down and 144 lb up at 10-0-0 on top chord , and 188 Ito down and 202 lb up at 5-0-0, 47lb down and 68lb up at 7-0-0, and 47lb down and 68 lb up at 8-", and 188 lb down and 2021b up at 9-114 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert 1-3=55, 3-0=55, 4-6=55, 9-12=20 Concentrated Loads (lb) Vert: 3=-60(F) 4=60(F) 8=188(F) 7=188(F) 15=58(F) 16=-58(F) 17=39(F) 18=39(F) mvq.lkNYngYrmYr M1'nntfrn65fg0ff1exil!ntlel Gm01[glnlLj 61013:rSF�me rArhoPPmemdMrm[wrwYnrM.,BY,wyOfi, ai4ldarLlwbRrll@imrWefwwm.lhn0nmratlmml0. Y YIIM1nncwrb[�dhmlmmi}90MM 4rLn�lmp(tpealle,fq�Eryfgnr!metleglLC�nmem�lavYmr�t uutlgaebrmlmll%5�mramOhvY^Jer:ns lgg9mmlW ery.wbRll. Nb' nmpru Nnm0uSf Mdiony T. Tom1YJ 111,. P.E. dmtlkrlm�bglelNgnmmm`��/43.m,m Orvrvdtia�lefYsblvfigMprv,whmaatldll{,b3:e1mptl4Yndrsil!W.1ngYntltlM1l00dgfie4,utlmimv Ynagmily¢mPnmBnedh.n JCMhm�mujlfEtl 280083 ' m p'lggl}nd4Grmi.l1uf wotl.bl[Tdbxvbtm1P13a5dMpJpghyuy YnFd'vO.Tf; r'0W h mdWlmNe:mlbpnipAau 1M1ItlL[mn,pzismtel6lq/mLnrgtiPr.Ims�nAYPnmIrm�YMme: w'n[ 4rt Lurie Blvd. nmms2wh.omgrmgae.®ghtlrm+[mmLL nrinuta,�Egmemrnbldiyoerya,n!m3!rca6gmegMu4 eeaaa,lem.rnmwumL � Fort Rem, FL 34946 0 i MOIOIIYI ivYllmsn-AmlYe LlomEl O. PE to fwivovblisfomne P!a / WY v4ielglmµisproLTnedwndanenmmpe,ds9whre411eol1neur�Au4lyt.taodnlO,t.L Job Truss Type Oty Ply WRMSCMB3L15X10 �Tmss HJ2 DIAGONAL HIP GIRDER 2 1 �RENARIVIORNINGSIDE A0118585 Job Reference (optional) A-1 Roof Trusses. Fort Pierce. FL 34946. d esignQal Wss.cem Run: 8.210 s May 18 2018 Print: 8210 s May 18 2018 MTek Industries, Inc. Wed Aug 29 15:28:55 2018 Page 1 ID:Id_OOXyyT61Bi_TXoljwHHzefvKy9rvDR6Ku98XAAHiJJgNEB4S Wyjhcg?FLSSSJOyiyu6 -1-70-10 2-9-3 1-10.10 I 2-93 LOADING(psf) SPACING- 2-M CSI. DEFL. in (hoc) I/defl Lid TCLL 20.0 Plate Grip DOL 1.25 TC 0.25 Vert(LL) 0.01 4-7 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.14 Vert(CT) -0.01 4-7 >999 240 BCLL 0.0 ' Rep Stress Ina NO WB 0.00 Horz(CT) 0.00 2 nla me BCDL 10.0 Code FBC2017rrP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 SOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or2-93 be pudins. BOTCHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation aide. REACTIONS. (lb/size) 3 = 45/Mechanical 2 = 242/0-10-7 (min. 0-1-8) 4 = 1811dechanical Max Horz 2 = 80(LC 4) Max Uplift 3 = -2(LC 9) 2 = -127(LC 4) 4 = -15(LC 19) Max Grav 3 = 47(LC 24) 2 = 242(LC 1) 4 = 63(LC 22) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; VuIY-160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf, h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TP1 I. - 3) Gable studs spaced at 2-0-0 oc. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurent with any other live loads. 5) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 2Ib uplift at joint 3, 127 lb uplift at joint 2 and 151b uplift atjoint 4. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 75 Ib dawn and 591b up at 1-4-9, and 75 lb down and 59 lb up at 1-4-9 on top chord, and 24 lb down and 34 lb up at 1-4-9, and 24 lb down and 34 lb up at 1-4-9 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) This truss is designed for a creep factor of 1.50, which is used to calculate the Vert(CT) deflection per ANSIrl-PI 1. The building designer shall verify that this parameter fits with the intended use of this component. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54,4-5=-20 PLATES GRIP MT20 2441190 Weight: 12 lb FT=10% ieuqM engtlhmeYb'4111Cf nJSill(�Illfl}eLi1tIW6r[4FgTGM1nf10Y(0.1933ffET.�'u'�e(III'len l„Of YYPPvfiudMenvtilL,uinpdugiln:d6,IM11.IsbglCMeu,ffnYMw.Otlnlphmu0MnM1W.u} ILnlmeel»SOiMMhWn01,MNJ. bllmlbvp[,ynN.1cW.IlI,P, rGe YV Rp'Tn,MvmPzdbpinNbgneelrtymJtlAlYble}a86uj,rn64ydivN1f0Y1,de1M.lYtnpnvmrunbdq�dn,ztmtldl Anthony T. Ter IILp.E. linghPv.hemte6Pd,yfYb NMgMgs,abmdgbl441CMbktlbt>3n4¢I1FI.n MAJdbbn tsq x80083 I Nwi iuntbgMtifgh4mry MIfYryMtudLtxr.icxsle,YYbNOdbrcm,+mlPlda.tl64J41rvlmeldAErocmi4Vi,INnb111111NllLLCMm.NYRm-0PJm 1FI MwiLmN iPt�,lnlbn[l•IwrN}n.1mf MT4P'n^e11mtYMve.vift A.ViRVdatrllwgOhliwi ILL,.M^e1[Wi, 445P SL Lun Blvd. leequ lddh10te,rxlquermlgh4Tn bgni hlnubupfgeu4nlble'raAPeryr,uln!hln±aapw[yWp Ng2hdknnntldWelOL FOR pierce, FL 34946 fe blO IDIA,VI IoalLvbes.lnlAov l.iom6vll4lE..le ndeaiovdtlisdommee is b s ,oAiEixd✓neeuh rrioev emininh..A 1Pad/nbn-Avfiatl LlxotolO, P.L- PP'P / V V vvl hip P 1 -— Job Truss seTyPly RENARMORNINGSIDEWRMSCMB31-15X10 A0118586 HJ5 [Dwiagonal Hip Girder 2 1 Job Reference (op0onag A-1 Roof Trusses, Fort Pierce, FL 34946, design@albuss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MTek Industries, Inc- Wed Aug 29 15:28:56 2018 Page 1 ID:Id_OOXyyT61Bi_TXoliwHHzefvK-8MXHRn7yTGOoKrusl MmPddGL2px6iPa5Bemyiyu5 -1-,("a 3-9-9 74)-2 ' 1 ,la I 3-9.9 ~ 3-2-9 a 3x4 = LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/deg L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.25 Ved(LL) -0.02 7-10 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.21 Vert(CT) -0.02 7-10 >999 240 BCLL 0.0 Rep Stress Iner NO WB 0.10 Hoa(CT) 0.00 5 n/a We BCDL 10.0 Code FBC20171TP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc puriins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required crass bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4 = 70/Mechanical 2 = 379/0-10-15 (min. 0-1-8) 5 = 178/Mechanical Max Horz 2 = 141(LC 22) Max Uplift 4 = -57(LC 4) 2 = -152(LC 4) 5 = -100(LC 5) Max Grav 4 = 77(LC 19) 2 = 379(LC 1) 5 = 178(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-11=392/103, 3-11=366/131 BOTCHORD 2-13=165/346, 7-13=1651346, 7-14=165/346, 6-14=-165/346 WEBS 3.6=383/183 NOTES- 1) Wind: ASCE 7-10; Vult--160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.0psh h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed; end vertical left exposed; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60 - 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-&0 tall by 2-M wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 57 lb uplift at joint 4, 152lb uplift at joint 2 and 100 lb uplift at joint 5. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 77 lb down and 61 lb up at 1-4-9, 77 Ib down and 61 Ib up at 14-9, and 32 lb down and 41 lb up at 4-2-8. and 32 Ib down and 41 lb up at 4-2-8 on top chord, and 63 Ib down and 35lb up at 1-4-9, 63 Ito down and 35 lb up at 1-4-9, and 14 lb down and 40 Ito up at 4-2-8, and 14 lb down and 40 Ito up at 4-2-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=54, 5-8=-20 Concentrated Loads (lb) Vert: 14=-9(F=-4, B=-4) PLATES GRIP MT20 244/190 Weight: 311b FT=10% IA nCmIInjfNajafi11f11Bt1%MOf4Q:tuT1-h�'1�[T.4JfR6n. rvryhdppuandielmnne:L,u0n4Sm+e0lt;dh NurLICM4111Aem,9:etin n. CM�uY.'v m•J¢deTVA,ay 41,imreplY.lypAnelly$nOnF•tlLe:elm�lnry(ryxfie.f,Mlryfqp.AmWngr®rtpe,nompnYmpBx�Intlnamm�q vliry3tmin4d0.rYj�r>a[gt4mN1E4,d1.4eM:Y4 Fn:mpaNnmG�.t+0dm1 Anthony T. Tmb0111, P.E. ednedM1+lmiSegbllynhnyx!&InfldO.,n,Mvmii.xaugepdvb MYgOn�pw,vnmmndM1tll6,vl¢ehebdl.Kaln1,¢lAl,n,dv,,,diuT9dakpnedwt"' W."W{ a:n....dYngJi :80083 ��6dqNmMndrmnp N4Ln10ugmdL5:e4.LgaipvinbiWdlYPbmtdplJmstlmfmRa rsynlfEq 6Ys®¢;161lm�ddel l4dnn,edremtYp,dphu 1Rl01¢b:¢patlp�¢lkmd41n:0,�lra.intin@epnmlrnu4+4Rr,nii[ 44515t. Lucie Blvd. ,}MUPeagAnpmm9d qnK¢mrrymlmendnL ttrmssergr4nuueWe.ux.lon�,ernsila.6yune¢rwfq mgavr.m.,nw.dnmA m Fort Pierce, FL 34946 (v IIQ)f011k11evgnsses-4ilm LlvmpeW.PJ. Pe eNmimvinulvmum,mav Iw¢,il w6mBNvieendermm mie4nhn41lamimunAvpp Llvmlel0,ra PPiI P P r P Pr r Job Truss Truss Type Oty Ply MORNINGSIDE WRMSCMB3L15X10J2 JACK -OPEN STRUCTURAL 9 118587 �RENAR Job Reference (ootionall - A-1 MOOT I MSSeS, ran Pierce, eL L1 b, 0eslgn(mai"ss.com R=8.21Us May la LUId ennh B.11U S May 18 Zc1b MileK lnaeSmes, Inc. Wea AUg291b2a:bt,ZUla LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) I/deft Lid TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.00 7 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.04 Vert(CT) -0.00 7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 nla n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 GOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc pudins. BOTCHORD Rigid ceiling directly applied or 10-0-0 cc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordancewith Stabilizer Installation uide. REACTIONS. (lb/size) 2 = 17610-7-10 (min. 0-1-8) 4 = 14/Mechanical 3 = 33/Mechanical Max Horz 2 = 63(LC 12) Max Uplift 2 = -60(LC 12) 3 = -24(LC 12) Max Grav 2 = 176(LC 1) 4 = 31(LC 3) 3 = 33(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; End., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable studs spaced at 2-M cc. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 601b uplift at joint and 24 lb uplift at joint 3. 8) This truss is designed for a creep factor of 1.50, which is used to calculate the Vert(CT) deflection per ANSI/TPI 1. The building designer shall verify that this parameter fits with the intended use of this. component. LOAD CASE(S) Standard PLATES GRIP MT20 2441190 Weight: 9lb FT = 10% 6nlq.IbmC qYr evd'Hllpl0l!0[RllajalJLLNNf r[PnAlttrilp!I�Y[bTM)krb;SJLLn'bb iMpbbFlenomnlrtlbn.pilmt M�n6mgiQd,Mhldxrl lMbOtl LldgnrllMMMm.Wm/m�m OM miPP,wj plhimmmlbm ltFrwmmmbYMJ.l.n,mbuptrpwpr.!,rNpu9. +aw ql>a rmunmwevabMmmerq.nngml.Wuvttmbspemsyatmsb!ad.mmoq.mtgt nLipmroLm.b/nmd^n_vwul Anthony T. Tombo III, P.E. WmJ4bim bvlmanb4mpJm./bPw bOmrr#CKryaeblwYq Pnp bnnntlbl4,mSWmbd1.hpMe erfM1t'bq{,M/bNldnhOnr,lbim�bbp9M§tbnebm4amlhYapbtib4 lwubd.d 480083 mrfr11x1xdlxYs.liaAf u'N.bNPMbIM,tmlpl/m,tlbrkbg4gaM!lgLitRm 7N 1,YUM1r111tlU11veMmb!mlmJ plyi Alhm.m mrerlea,mlNndmlmbape.l of bfp4y.etllm.YaMaxe.snt 44515t. Lurie BNd. r4enu NeYlnbs lyrtlqubwRghApiami,LL RImlGplq�x6Rldtdfap:q�,r,im1!paFgma6mr MVW N4MrAMmvenlrtaq Yiltl. Fort pierce, FL 34946 6 d10 Mlddi fe<ITnms-Idea LTemhatlLPl. Ir rawl don dammM>ev tar n rvl3drdibhod,.61" nnriuinfim 4110 Lnunh6n tlodb lit, LL PP'1 I p 9 vV p p I - --.-...�.�.. Job Truss Truss Type oty Ply MORNINGSIDE WRMSGMB3L15X10 J5 Jack -Open 4 1 �RENAR A0118588 4 Job Reference o tional ry agn¢v, ve5i9.Lma, uuss.com Kun: o.ziu s may to zuia Ynm: mziu s may la zu18 muex mausmes, Inc. Wed Aug 2915:28:57 2018 E 3x4 = 5 0-0 LOADING(psf) SPACING- 241-0 CSI. DEFL. in (loc) Ildeff L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.49 Ved(LL) 0.11 4-7 >554 360 MT20 244/190 TCDL 7.0 Lumber DOL 125 BC 0.44 Vert(CT) 0.09 4-7 >650 240 BCLL 0.0 ' Rep Stress Ina YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/rPI2014 Matdx-MP Weight: 18 lb FT=10% LUMBER - TOP CHORD 2x4 SP No.2 BOA CHORD 2x4 SP No.2 mechanical connection 5 ) Providehil by others) ) of truss BRACING- to hearing plate capable of withstanding 81 lb uplift at TOP CHORD joint 3, 98 lb uplift atjoint 2 and 48 lb uplift at joint 4. Structural wood sheathing directly applied or 5-0-0 oc pudins. BOT CHORD LOAD CASE(S) Rigid ceiling directly applied or 10-M ore bracing. Standard MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide.. REACTIONS. (lb/size) 3 = 113/Mechanical 2 = 269/0-8-0 (min. 0-1-8) 4 = 59/Mechanical Max Horz 2 = 123(LC 12) Max Uplift 3 = -81(LC 12) 2 = - -98(LC 9) 4 = -48(LC 9) Max Grav 3 = 113(LC 1) 2 = 269(LC 1) 4 = 88(LC 3) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vu1t=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. II; Exp B; Encl.. GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed; porch left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. ceawa¢m.prm..b•u umlmsaC�tuulariunua[Tzar¢nlmorfrm7+.utrsrrlrm•I,g1,Wrammd¢abn.Ml anpa..alrtr,MMm.rl.l nnlEwv uensmn,. uetmwn aex blm,sy nu.a¢,mlrn¢mbmlmbmnw.ea. rtal ntrr�prq•e(�apwsyn+1.mutlenampigmem¢.mrexvyamagseveml.way�Mtrpao.ta,,l yea Mmo¢ry,w 141 Ma.1ar.+rap:,aktgoen s+emuy Mthony T. Tomho III, P.E. ' dwtlNalm 4gMiAgbYmrybLLytlbpran.MO.uftn*svdga[aM1ltY�gd,ipr¢4mn4tltrG,b L'M4WI YnnitmtlM bglrmliWl4oNmbtl ,IMi tkl�EgL�fegn..q em®me¢1Frtaydtl YO rn Vstl 180083 bl."WMdeeve.L9¢rtuar4mUM4ptletnlygYvntlYlWBg4gaielArylsYam¢I�A,rWNNfI111gYn rtleaw4pmJP6ve, Rl65u eentps4mtefbra[M4ntdvpe.l.ntlnp4yaeellnnaaM.. ¢ e4e.nrNgln(ofayMrmgrimglamrnnM441MinurWfqem41CI416lqM1m,rt1"sslrytaEgrat [erWq Wg2a4k¢ en Nnabllll. 44515t. Lurie Blvd. • Fort Pierm, FL 34946 Gppi111®}pllkl ixl4rues-Avuary LlomEJA,pl lapn:a4iee Mllndonrvm,i000lfomispoll4k¢nlamne rrinn pzwieahanli Ieolhauer4tl,veyLrem1o10,L[. Job n Tmss TlussType Oty Ply WRMSCMB31-15X10TO1GE COMMON 1 �RENARMCRNINGSIDE 1 A0118589 Job Reference o tional — n-T nooT tmsses. ron rierce, rL aaaao, aes,gnraa3wss.com nun: a.zTu s may is zuiornnr. o.<m s may t a zu to mt 4x4 = 5 LOADING(psf) SPACING- 2-0-0 CSL DEFL. in (loc) Well Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.35 Vert(L) 0.05 13 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.40 Vert(CT) -0.04 13 >999 240 BCLL 0.0 Rep Stress lncr YES WB 0.10 Horz(CT) 0.00 11 nla n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MR LUMBER. TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No-2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or6-" oc pudins, except end verticals. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 15 = 41810-3-8 (min. 0-1-8) 11 = 41810-3-8 (min. 0-1-8) Max Horz 15 = 76(LC 11) Max Uplift 15 = -170(LC 8) 11 = -170(LC 9) Max Grav 15 = 418(LC 1) 11 = 418(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. WEBS 3-15=2001335, 7-11=2001335 NOTES. 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are 1.5x4 MT20 unless otherwise indicated. 4) This truss has been designed for a 10.0 psi bottom chord live load nonconcument with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 170lb uplift at joint 15 and 170 lb uplift at joint 11. 7) This truss is designed for a creep factor of 1.50, which is used to calculate the Vert(CT) deflection per ANSIrFPI 1. The building designer shall verify that this parameter fits with the intended use of this component. LOAD CASE(S) Standard mc. vveu nug<a Ta:<aar<utu PLATES GRIP MT20 2441190 Weight: 47 lb FT=10% iewl.h,ubultl.mnrmnl npp0hiqrffiflTlel4mal(uF'NfaU0011(n1P 3a1Tlna.Inf(bvplvuAwndndnnannimEnAYr,Yq(RC,niM1INg1.4rY411LbmYNSena Oin!Mnu vfda4ID0.rj G01ur¢mlo!!IiNnNhM1avnM�tld.1!rl,n!Rilpfpne0,.1Ru!ry4p!M1btutlenWtrynm!oalmtlMPAn!WupaNltNmInik4lnQAbnjtlmr L9atlwbQO�p.obP.11. Tsinp Na/al.btlgmaY!r�A�bT Anthony T. TOmbo III, P.E. dntlbYrm!MgbEq!M1tvp!iWtl60.m.MO+ssitrfaNggtln4bMq Mipn,rbMtlAblCb0.nIM1Wtl6Yapplt WlFl RgynAiM1R4dapytx AOtin!tbllgM9q 4'q,.M1klfaWMp!IdMM1n:rmYgtl =80083 ' M1ledyM!{e vitro+t•.anff!eearMi[9rAdpmmvofNtlmAo!Nnq(nixu 4'q bxas',D51J��L!1J 11111dP[In2savl4 pttlplm P.lein!t•!�y.Nn,dbm Rbl.nt Ruin.l.n, S!ALAneflmsW,lnn.nMt tit. rude anrNl&tllnrMOq,dtpban:ghtllla!wwLei LnTnuQV}rryuul!Itli6laiapiwgr,aT,nsfivafgbtntlq W1q J. UopkomahbWbTm. Fort Pierce, FL34944946 (o M® . ppir 1016 Ad betLassa�AoiEva11.1ombatl6p1.lrpedoeioeehlidonmenr,ivaglmyilptol2uetl ri@anAtevtmeapwminiotlhomkl ledLaTa�le�EoopCromlall4pl-- _— _ JANUARY 17, 2017 I TYPICAL HIP / KING JACK CONNECTION I STDTL01 r t CORNERSET GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 175 mph, ASCE 7-10, Exp. B, C up to 60' Mean Roof Height and Exposure D up to 30' Mean Roof Height. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 Attach End Jack's w/ (4) 16d Toe Nails @ TIC & (3) 16d Toe Nails @ BC Attach King Jack w/ (3) 16d Toe ,Nails @ TIC & 24" Strap w/ (6) 10d x 1.5" ea. end @ BC 0 ti ttach Corner Jack's d (2) 16d Toe Nails @ TIC & BC (Typ) Attach Comer Jack's w/ (2) 16d Toe Nails @ TC & BC (Typ) 0 ya WrmYtr�mYYPLLt ta.pgn,yYF M�1aP'°'r�+art m'Orcn arpa,+a'+u+gvi,feWYnYbbuy+bvpe 2pN Ypaq.mntt:ncupmryee.ro+gWa.nanti� Anthon,l.Tmn6o0(, P.E. m +p rub urges }ml-mama YtltOau�ep butna'.wroaumebr r3(siOirYYtgagetl2l Agpb+dexs /mt .Lywti.t aggc gm�oym Yb�npmn+ r YkatYGwmsna u�Km asimArarnmteseNalshv4ew!'dlsaameNFMSbIriRetm� Me�cakir+A mj mlaa TnMim,+a M�evsaL.vtim[mmeeMUMe.9etw A WP83 wm amhiumagnia+e bchdfpatMm i4tTi+a.Tigmb4TrfsfgYupv t �4 Y,.va Yky 4rgetlYn tM ial • ... .cn... �.., ... ,.� ,. ...._ .,.:...a ., ,_, ..... .. :. St de FortPierce, FL U94 6 FEBRUARY 17, 2017 I ALTERNATE GABLE END BRACING DETAIL 1 STDTL03 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 T/2d031010 ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORO 1'-3' MAX. DIAG. BRACE AT 1/3 POINTS IF NEEDED IT IS THE RESPONSIBILITY OF THE BLDG. DESIGNER OR THE PROJECT ENGINEER/ARCHITECT TO DESIGN THE CEILING DIAPHRAGM AND ITS ATTACHMENT TO THE TRUSSES TD RESIST ALL OUT OF PLANE LOADS THAT MAY RESULT FROM THE BRACING OF THE GABLE ENDS. HORIZONTAL BRACE (SEE SECTION A -A) TRUSSSES 24' D.C. 2X6 DIAGONAL BRACE SPACED 49' OL. ATTACHED TO VERTICAL WITH (4) - 16d NAILS, AND ATTACHED TO BLOCKING WITH (5) - IOd COMMONS. NAIL DIAGONAL BRACE TD PURLIN WITH TWO 15d NAILS. 2X4 PURLIN FASTENED TO FOUR TRUSSES WITH (2) - 16d NAILS EACH. FASTEN PURLIN TO BLOCKING W/ (2) - 16d NAILS (MIN.). PROVIDE 2X4 BLOCKING BETWEEN THE TRUSSES SUPPORTING THE \BRACE AND THE TWO TRUSSES ON \EITHER SIDE AS NOTED. TOENAIL \ BLOCKING TO TRUSSES WITH (2) - \ lOd NAILS AT EACH ENO. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - 10d COMMON WIRE NAILS. ENO WALL CEILING SHEATHING BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED: METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE OF THE STRUCTURAL GABLE AND FASTEN PER THE FOLLOWING NAIL SCHEDULE. METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. VERTICAL NAILING SCHEDULE: - FOR WIND SPEEDS 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE 7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (331' X 3') NAILS SPACED S' O.C. - FOR WINO SPEEDS GREATER 120 MPH (ASCE 7-9B, 02, 05), 150 MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF Uld (131'X3') NAILS SPACED 6' D.C. (2X4 STUDS MINIMUM). STRUCTURAL GABLE TRUS! MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALI BRACING METHODS SHOWN ON PAGE 1 ARE VALID AND ARE TO BE FASTENED TO THE SCABS OR VERTICAL STUDS OF THE STANDARD GABLE TRUSS ON THE INTERIOR SIOE OF THE STRUCTURE. NOTE: THIS DETAIL IS TO BE USED ONLY FOR STRUCTURAL GABLES WITH INLAYED STUDS. TRUSSES WITHOUT INLAYED STUDS ARE NOT ADDRESSED HERE. STANDARD GABLE I TRUSS RAL TRUSS STUB AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS. THE BRACING SHOWN IN THIS DETAIL IS FOR VERTICAL/STUDS ONLY. JULY 17, 2017 STANDARD PIGGYBACK TRUSS I STDTL04 J CONNECTION DETAIL THIS DETAIL IS APPLICABLE FOR THE FOLLOWING WIND CONDITIONS: ASCE 7-98, ASCE 7.02, ASCE 7-05, ASCE 7-10 WIND STANDARDS UNDER ALL ENCLOSURE AND EXPOSURE CONDITIONS AS LONG AS NO UPLIFT EXCEEDS 377 LBS. REFER TO ACTUAL PIGGYBACK TRUSS DESIGN DRAWING FOR UPLIFTS. NOTE: THIS DETAIL IS VALID FOR ONE PLY TRUSSES SPACED 24. O.C. OR LESS A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-009-1010 PIGGYBACK TRUSS REFER TO ACTUAL TRUSS DESIGN DRAWING FOR ADDITIONAL PIGGYBACK TRUSS INFORMATION. SPACE PURLINS ACCORDING TO THE MAXIMUM SPACING ON THE TOP CHORD OF THE BASE TRUSS (SPACING NOT TO EXCEED 24' OL.) A PURLIN TO BE LOCATED AT EACH BASE TRUSS JOINT. ATTACH PIGGYBACK TRUSS TO THE BASE TRUSS WITH 2' X 8' TEE -LOCK MULTI -USE CONNECTION PLATES SPACED 48'O.C. PLATES SHALL BE PRESSED INTO THE PIGGYBACK TRUSS AT 48' O.C. STAGGERED FROM EACH FACE AND NAILED TO THE BASE TRUSS WITH FOUR (4) BA (1-5' X 0.099-) NAILS IN EACH PLATE TO ACHIEVE A MAXIMUM UPLIFT CAPACITY OF 377 LBS. AT EACH 2' X 8' TEE -LOCK MULTI -USE CONNECTION PLATE. (MINIMUM OF 2 PLATES) ATTACH EACH PURLIN TO THE TOP CHORD OF THE BASE TRUSS. (PURLINS AND CONNECTION BY OTHERS) BASE TRUSS REFER TO ACTUAL TRUSS DESIGN DRAWING FOR ADDITIONAL BASE TRUSS INFORMATION. ^'^ram rt�PwFaLartint wal.gniMehgle F+t'a+19 AnwMnruo-Mmu(.sn b uTX k• m ' a ehelvib I.igeh amaaibo eie.e+mtreiep brlxA4n h,w,as. k. wmmww, nnw to N"dm tmW M ihwa.awalei:y�+wm*S3 re.gerbo-�.w.+'Aa AnthonyhonY SFU, P.E. wMlgfrpnr4bwrLmtutggY6{WMi�iMPidy+i4lNAgUapulMN.veM tSpkMFtUM3'l nkm16p0}Iw pNlMh.µea+LtdV Ow/wtbvps 4nfhepfipgelLn Ybha,H:t m..ua^w7 f ry.i,a. :SM4l�b1FAq hhnCYe6Fw CIbbT11Wp bmuthebpwiwr+lF1 ggCNYbv NwYTt 4481St. w FL 3494 • r...e...•�mnun .au.......w ..u.m .� .� ..._._ _._ �__...�.... .._.. ,.. .. Fat Plerre, Ft 3<946 JULY 17, 2017 1 TRUSSED VALLEY SET DETAIL - SHEATHED I STDTL05 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409A010 GABLE END, COMMON TRUSS, OR GIRDER TRUSS GENERAL SPECIFICATIONS: 1. NAIL SIZE =3'X 0.131'=10d 2. WOOD SCREW= 4.5'WS45 USP OR EQUIVALENT. 3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES. 4. INSTALL VALLEY TRUSSES (24- O.C. MAXIMUM) AND SECURE TO BASE TRUSSES AS PER DETAIL'A'. S. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIDUAL DESIGN DRAWINGS. 6. NAILING DONE PER NDS- 01. 7. VALLEY STUD SPACING NOT TO EXCEED 48' O.C. GABLE END, COMMON TRUSS, OR GIRDER TRUSS TRUSS CRITERIA: SECURE VALLEY TRUSS WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH W/ ONE ROW OF 10d WIND DESIGN PER ASCE 7-10: 170 MPH NAILS 6' O.C. MAX MEAN ROOF HEIGHT= 30 FEET ROOF PITCH = MINIMUM 3112 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE WIND DURATION OF LOAD INCREASE: 1.60 MAX TOP CHORD TOTAL LOAD =50 PSF ATTACH 2X4 CONTINUOUS #2 MAX SPACING = 24' O.C. (BASE AND VALLEY) SYP TO THE ROOF W/ TWO USP MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. WS45 (1/4-X 4.5') WOOD SCREWS INTO EACH BASE TRUSS. DETAIL A Antho.y T. Tnmlw 111, P.E. 80083 4451 St tune Blvd. F&t Pierce; FL. 34946 FEBRUARY 5, 2018 TRUSSED VALLEY SET DETAIL STDTL06 4 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 SECURI W/( VALLEYTRUSS (TYPICAL) GABLE END, COMMON TRUSS, OR GIRDER TRUSS DETAIL A (NO SHEATHING) N.T.S. GENERAL SPECIFICATIONS: 1. NAIL SIZE =3'X 0.131'=10A 2. WOOD SCREW = 3' WS3 USP OR EQUIVALENT. 3. INSTALL VALLEY TRUSSES (24- O.C. MAXIMUM) AND SECURE PER DETAIL 'A'. 4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN DRAWINGS. 5. BASE TRUSS SHALL BE DESIGNED WITH A PURUN SPACING EQUIVALENT TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING. 6. NAILING DONE PER NDS-01. 7. VALLEY STUD SPACING NOT TO EXCEED 48' O.C. P F 12 SEE DETAIL'A' BELOW (TYP.) BASETRUSSES GABLE END, COMMON TRUSS, OR GIRDER VALLEY TRUSS TRUSS (TYPICAL) WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH MINIMUM 3112 MAXIMUM 6112 CATERGORY II BUILDING EXPOSURE WIND DURATION OF LOAD INCREASE: 1.60 ATTACH 2X4 CONTINUOUS Art MAX TOP CHORD TOTAL LOAD = 50 PSF SYP TO THE ROOF W/TWO USP MAX SPACING = 24' O.C. (BASE AND VALLEY) WS3(1/4-X3-)WOOD SCREWS MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. INTO EACH BASE TRUSS. bsd 'o bvbwsrmmaxbw lnmamW�P 4aq'th*Sl+rwugtu bnmer.ge�i IN ro-w mmimn'Nierrmy,wpae.rekrwmrmd rvnq..rtnl mewaw m++ozu.i ':+ MIhcM' T.Tmbo III, P.E. ' ra de,lrrsrvglrYy m vaNamacr,Yfmh Wmrlep bkYyte}r bmv mGfeo(HdNbaYgrWeltll)%g4mm"'W dbM eOugemq,vgr aubvatiq bbrepde/t B6BB3 bhbg6rmenellwx UrmwmmS9dbrwnmyuombmbllvlrrYegbevabl+�,r<4dhPIml2l.,Na blremp}bdm♦l tlmb�dfmrtbfmrAap mnOry[epnol[ mrd vrr,.xx iciL Z151 St ¢Blvd. m.xu_eWlhtrengedp®e>{bnperwArl blrnrbcp RerxdAdslaAq&.�a S;e.6padn Wv uquedbnnnta4aul • .. _. - .. _.--_. FartI St ; FL34946 JULY 17, 2017 1 1 V 1"" I `'L 1 "` 1llIL_ STDTL07 (HIGH WIND VELOCITY) A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 ATTA( WIND DESIGN PER ASCE 7-98. ASCE 7- WIND DESIGN PER ASCE 7-10: 170 MPI MAX MEAN ROOF HEIGHT= 30 FEET CATERGORY II BUILDING EXPOSURE B OR C WIND DURATION OF LOAD INCREASE: MAX TOP CHORD TOTAL LOAD = 50 PSI MAX SPACING = 24" O.C. (BASE AND VF SUPPORTING TRUSSES DIRECTLY UNrjm < VnLL�l . nUa=. mU.. e. DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2'- 10' ON AFFECTED TOP CHORDS. NOTES: 1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES. 2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES LUMBER. NON -BEVELED BOTTOM CHORD FOR BEVELED BOTTOM CHORD, CLIP MAY BE APPLIED TO EITHER FACE. CLIP MAY BE APPLIED TO THIS FACE UP TO A MAXIMUM 6112 PITCH NON -BEVELED BOTTOM CHORD CLIP MUST BE APPLIED TO THIS FACE WHEN PITCH EXCEEDS 6112 (MAXIMUM 12/12 PITCH) x¢sq.Iflateaj4m •#'H i'v9fiPJfS(1jIS.IB}i igli Ii16{lCf�16fS0.Sd({fil)!:M`.(p11C i�i fYdrMppRMpMi¢1a61kniklp QuTi i97Mb1Mnf ipL41! IAn�pi�km:u phnemaCRia#ip0.M¢ /� FLF ass,biJ3k IbbROnYrtlRltl lkpquc{,Y«tgs+batl ullP'y�+v0 npsltlplMnt>dn,.�w7mpde+iubbu}diuq.i Lpd YtlW,MRF: bh�pavgei btl �.Imi+.wSSn Mthony T. T23 III, P.E. ///' \ d dmi 1 v,Itlfvl.pnyn ,Y010 bC txwaipePpkWlkHie..Msetiv RbRdbkdn•p�diM:bmnatlp'0al fillladvintsWplst; TM4.mtldlnih¢q�sdbpmc�?ul� F'80C3 hkibituq+dlntle naanwaallWdwywudpkwndmbvq vrramfae!.kmm(t(..,dnlelpind.[i Mn;dvlrNT�ar.lnl4he vagn.ia WMndp lmaWvyv. va4wpfymdhnYmexm,a+m 44515L Lucie Blvd. kr«vNMplli�Mgalaws �+Shbl+aandd la kcPlgmv Wividtrq k:ym 4 S.am6pAdn WWi ingxM1,.im.ly kfni 9Vi. Foil Pik R. 34946 FEBRUARY 17, 2017 1 STANDARD GABLE END DETAIL I STDTL08 " A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 TYPICAL 2X4 L-BRACE NAILED TO 2X4 VERTICALS V/10d NAILS, 6' O.C. VERTICAL STUO SECTION B-B TRUSS GEOMETRY AND CONDITIONS SHOWN ARE FOR ILLUSTRATION ONLY. DIAGONAL BRACE 4' - O. OL. MAX. SEE INDIVIDUAL ENGINEERING DRAWINGS FOR TRUSS DESIGN CRITERIA. 12 Q VARIES TO COMMON 'TRUSS 3X4 = v * DIAGONAL BRACING )F'k L - BRACING REFER REFER TO SECTION A -A TO SECTION B-B 24' MAX. NOTE: 1. MINIMUM GRADE OF N2 MATERIAL IN THE TOP AND BOTTOM CHORDS. 2. CONNECTION BETWEEN BOTTOM CHORD OF GABLE END TRUSS AND WALL TO BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT. 3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG. ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF SYSTEM. 4. L' BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR SP #3 OR BETTER WITH ONE ROW OF 10d NAILS SPACED 6' D.C. 5. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM AT 4'-0'D.C. E. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN WITH 16d NAILS SPACED 6' O.C. HORIZONTAL BRACE TO BE LOCATED AT THE MIOSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE STUDS WITH (3) IDd NAILS THROUGH 2X4 (REFER TO SECTION A -A) 7. GABLE STUD DEFLECTION MEETS OR EXCEEEDS L/24D. VERTICAL 2X6 SP OR SPF STUDVBRACE #2 DIAGONAL BRACE (4) - 16d NAILS16d NAILS SPACED 6' D.C. (2) IDd NAILS INTO 2X62X6 SP OR SPF @2 2X4 SP OR SPF #2L HORIZONTAL NAILED TO RTICALS SECTION A -A W/(4) - IDd NAILS PROVIDE 2X4 BLOCKING BETWEEN THE FIRST TWO TRUSSES AS NOTED. TOENAIL BLOCKING TO TRUSSES WITH (2) - 10d NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - 10d NAILS (4) Bd NAILS MINIMUM, PLYWOOD SHEATHING TO 2X4 STD SPF BLOCK B. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. DIAS. BRACE 9. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1/3 POINTS TRUSSES. IF NEEDED 30. IDd AND 16d NAILS ARE 0131'X31' AND 0131'X35- COMMON WIRE NAILS RESPECTIVELY. 11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12 BY SPIB/ALSC. MINIMUM STUD SIZE SPECIES AND GRADE STUD SPACING WITHOUT BRACE 2X4 L - BRACE DIAGONAL BRACE 1 (2) DIAGONAL BRACES AT 1 1/3 POINTS MAXIMUM STUD LENGTH 2X45P#31STUD 12'O.C. 36-10 5&11 6-6.11 11-1-13 2X4SP#3/STUD i6'O.C. 3-3-10 4-9-12 66-11 9-10-15 2X4sP#3/STUD 24'O.C. 2-6-6 3-11-3 5-4-12 8-1-2 2X45P#2 12. O.C. E-10.15 56.11 66-11 11-8-14 2X4 SP 1R 16'O.C. 36.11 4-9-12 66-11 1066 2X4 SP#2 24, O.C. 3-i-4 3-11-3 6-2-9 9-3-13 DIAGONAL BRACES OVER 6' - 3' REQUIRE A 2X4 T-BRACE ATTACHED TO ONE EDGE. DIAGONAL BRACES OVER 12' - 6' REQUIRE 2X4 I -BRACES ATTACHED TO BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE [IF DIAGONAL BRACE WITH 10d NAILS 6' Q.C., WITH 3' MINIMUM END DISTANCE. BRACE MUST COVER SIM OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP N2. ROOF SHEATHING 1/5 (2) - 10d NAILS "TRUSSES @ 24' O.C. 2X6 DIAGONAL BRACE SPACED 48' OL. ATTACHED TO VERTICAL WITH (4) - 16d NAILS, AND ATTACHED TO BLOCKING WITH (5) - 10d NAILS. HORIZONTAL BRACE (SEE SECTION A -A) END WALL 7-10 190 MPH STUD DESIGN IS BASED ON COMPONENTS AND CLADDING. (ION OF LOAD INCREASE: 1.60 1 CONNECTION OF BRACING IS BASED ON MWFRS. s FEBRUARY 17, 2017 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 WITH 2X BRACE ONLY DOTES: f—BRACING / I —BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING :5 IMPRACTICAL. T—BRACE / I —BRACE MUST COVER SP/. OF WEB LENGTH. PHIS DETAIL NOT TO BE USED TO CONVERT T—BRACE / I —BRACE WEBS TC ;ONTIN000S LATERAL BRACED WEBS. NAILING PATTERN T-BRACE SIZE NAIL SIZE NAIL SPACING 2X4 OR 2X6 OR 2XB 10d 6' O.C. NOTE NAIL ALONG ENTIRE LENGTH OF T—BRACE / I —BRACE (ON TWO—PLY TRUSSES NAIL TO BOTH PLIES) STDTL09 BRACE SIZE FOR ONE -PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T—BRACE 2X4 I —BRACE 2X6 2X6 T—BRACE 2X6 I —BRACE 2X8 2X8 T—BRACE 2X8 1—BRACE BRACE SIZE FOR TWO-PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T—BRACE 2X4 I —BRACE 2X6 2X6 T—BRACE 2X6 I —BRACE 2X8 2X8 T—BRACE 2X8 I —BRACE T—BRACE / I —BRACE MUST BE SAME SPECIES AND GRADE (OR BETTER) AS WEB MEMBER. NAILS NAILS WEB %( NAILS WEB I -BRACE T-BRACE SECTION DETAILS FEBRUARY 17, 2017 LATERAL BRACING RECOMMENDATIONS I STDTL10 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS, 2XG 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY 8 TO 10 FEET ALONG A FLOOR -TRUSS._ NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY OF THE METHODS ILLUSTRATED BELOW. NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS FROM END TO END, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY CONNECTED, BY OTHERS, AT THE ENDS. USE METAL FRAMING '1 ANCHOR TO ATTACH TO TOP CHORD BLOCKING BEHIND THE VERTICAL WEB IS RECOMMENDED WHILE NAILING THE STRONGBACK INSERT WOOD SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRDNGBACK (DO NOT ATTACH TO VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS) WEB WITH (3) - IOd SCAB WITH (3) - 10d NAILS (11131' X 3') NAILS (0131' X 3). ATTACH TO VERTICAL WEB WITH (3) - lad NAILS (D331' X 3') USE METAL FRAMING ATTACH TO VERTICAL ANCHOR TO ATTACH WEB WITH (3) - 10d TO BOTTOM CHORD NAILS (0131'X 3') ATTACH 2X4 VERTICAL TO FACE OF TRUSS. FASTEN TO TOP AND BOTTOM CHORD WITH (2) - 10d NAILS (0131' X'3') IN EACH CHORD ATTACH TO VERTICAL SCAB WITH (3) - IDd NAILS (0131' X 3') TRUSS 2X6 4' - D' J WALL STRONGBACK r (TYPICAL SPLICE) - I (BY OTHERS) ATTACH TO CHORD WITH (2) #12 X 3' WOOD SCREWS (0216' OIA1 INSERT SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (DO NOT USE DRYWALL TYPE SCREWS) THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEQUATE SUPPORT, DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' - D' LONG SCAB CENTERED ON THE SPLICE AND JOINED WITH (12) - 10d NAILS (0131' X 3') EQUALLY SPACED. ALTERNATE METHOD OF SPLICING: OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' - 0' AND FASTEN WITH (12) - IOd NAILS (0131' X 3') STAGGERED AND EQUALLY SPACED (TO BE USED ONLY WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL). BLOCKING (BY OTHERS) FEBRUARY17,2017 1 LATERAL TOE -NAIL DETAIL I STDTL11 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772 409-1010 NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45• WITH THE MEMBER AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER ENO AS SHOWN). 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES FOR MEMBERS OF DIFFERENT SPECIES. TOE -NAIL SINGLE SHEAR VALUES PER NOS 2001 (LB/NAIL) OIA SP OF HF SPF SPF-S .131 88.0 80.6 69.9 68.4 59.7 U o .135 93.5 85.6 74.2 72.6 63.4 J N .162 108.8 99.6 86.4 84.5 73.8 �i .128 74.2 67.9 58.9 57.6 50.3 z p .131 75.9 69.5 60.3 59.0 51.1 J N .148 81.4 74.5 64.6 63.2 52.5 ri THIS DETAIL IS ONLY APPLICABLE TO THE THREE END DETAILS SHOWN BELOW. SIDE VIEW (2X3) 2 NAILS NEAR SIDE FVT- NEAR SIDE VALUES SHOWN ARE CAPACITY PER TOE -NAIL SIDE VIEW APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. (2X4) 3 NAILS EXAMPLE: NEAR SIDE (3) - 16d NAILS (0162' OIA. X 35') WITH SPF SPECIES BOTTOM CHORD IVE NEAR SIDE FOR LOAD DURATION INCREASE OF IAS: NEAR SIRE 3 (NAILS) X B45 (LB/NAIL) X 115 (DOL) = 2915 LB MAXIMUM CAPACITY ANGLE MAY VARY FROM 30' TO 60' 45.00' ANGLE MAY VARY FROM 30' TO 60" 45.00° SIDE VIEW (2X3) 2 NAILS NEAR SIDE NEAR SIDE NEAR SIDE NEAR SIDE ANGLE MAY VARY FROM 30• TO 60' 45.000 FEBRUARY17,2017 1 UPLIFT TOE -NAIL DETAIL I STDTL12 A-1 ROOF TRUSSES 4451 5T. LUCIE BLVD. FORT PIERCE. FL 3494 772409-1010 THIS DETAIL SHALL BE USED FOR A CONNECTION RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS. NOTES: TOE -NAIL WITHDRAWAL VALUES PER NOS 2005 (LB/NAIL) DIA. SP OF HF SPF SPF-S L7 .131 59 46 32 30 20 z J .135 60 48 33 30 20 (*1 .162 72 58 39 37 25 J 2 (, .126 54 42 28 27 19 r Z Z OJ .131 55 43 29 28 19 LU .148 62 48 34 31 21 J Lf7 J N Q M Z .120 51 39 27 26 17 Z .128 49 38 26 25 17 O .131 51 39 27 26 17 0 .148 57 44 31 28 20 17 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30• WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER ENO AS SHOWN. 2 THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION. VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0162' DIA. X 35') WITH SPF SPECIES TOP PLATE FOR VINO DOL OF 133: 3 (NAILS) X 37 (LB/NAIL) X 133 (ODL FOR VINO) = 148 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND FOR WIND DOL OF 1.60: 3 (NAILS) X 37 (LB/NAIL) X 150 (COL FOR WIND) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO VINO IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN CRAVING EXCEEDS 147 LBS (177 LBS) BUILDING DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION. *++ USE (3) TOE -NAILS ON 2X4 BEARING WALL +*+ USE (4) TOE -NAILS ON 2X6 BEARING WALL NEAR SIDE FAR S L TOP PLATE OF WALL VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY L NAIL NAIL SIDE VIEW END VIEW FF,BRUARY 5, 2016 TYP 2x2 NAILER ATTACHMENT I STDTL13 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 l.0 X 4 2x2 NAILER ATTACHMENT GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 170 mph, ASCE 7-10, 29'-0" Mean Height, Exp. B, C or D. April 11, 2016 TYPICAL ALTERNATE BRACING DETAIL FO EXTERIOR FLAT GIRDER TRUSS STDTL14 FA A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 (4) 12d .. TRUSS 2411 O.C. UPLIFT CONNECTION (SEE ROOF TRUSS) EXTERIOR FLAT - GIRDER 12 VARIES (4) 12d MAX 3011 (21-611) 2x6 #2 SP (Both Faces) 2411 O.C. SIMPSON H5 A Nosy T. Twn 111, D.E. s M53 4451 6t, bx BIM, fort PI., R 34946 �FEBRUARY 17 2017 I STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND STDTL15 DAMAGED OR MISSING CHORD SPLICE PLATES A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 7724091010 TOTAL NUMBER OF NAILS EACH SIDE OF BREAK * X (INCHES) MAXIMUM FORCE (LBS) 157 LOAD DURATION SP OF SPF HF 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 20 30 24• 1706 2559 1561 2342 1320 1980 1352 2028 26 39 30• 2194 3291 2007 3011 1697 2546 173E 2608 32 48 36• 2681 4022 2454 3681 2074 3111 2125 3187 38 57 42• 3169 4754 29DO 4350 2451 3677 2511 3767 44 66 48• 3657 5485 3346 5019 2829 4243 2898 4347 DIVIDE EQUALLY FRONT AND BACK ATTACH 2X_ SCAB OF THE SAME SIZE AND GRACE AS THE BROKEN MEMBER TO EACH FACE OF THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR 2X4, THREE ROWS FOR 2X6) SPACED 4' O.C. AS SHOWN (131' CIA. X 3'). STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' O.C. SPACING IN THE MAIN MEMBER. USE A MIN. 3' MEMBER ENO DISTANCE. THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS) THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X + C 1. L,(yPl G �Z • 10d NAILS NEAR SIDE + 10d NAILS FAR SIDE BREAK TRUSS CONFIGURATION AND -BREAK LOCATIONS FOR ILLUSTRATIONS ONLY X' MIN �— 6' MIN THE LOCATION OF THE BREAK MUST BE GREATER THAN OR EQUAL TO THE REQUIRED X DIMENSION FROM ANY PERIMETER BREAK OR HEEL JOINT AND A MINIMUM OF 5' FROM ANY INTERIOR JOINT (SEE SKETCH ABOVE). DO NOT USE REPAIR FOR JOINT SPLICES NOTES: 1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR DOES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF SUPPORTING THE LOADS INDICATED. 2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR AND HELD IN PLACE DURING APPLICATION OF REPAIR. 3. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. S. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2X_ ORIENTATION ONLY. 6. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS. FEBRUARY 17, 2017 SCAB APPLIED OVERHANGS STDTL16 �. &I ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 TRUSS CRITERIA: LOADING: 40-10-D-10 DURATION FACTOR: - 115 SPACING• 24' D.C. TOP CHORD: 2X4 OR 2X6 PITCH: 4/12 - 12/12 HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL END BEARING CONDITION NOTES: 1. ATTACH 2X-SCAB (MINIMUM #2 GRADE SPF, HF, SP, OF) TO ONE FACE OF TRUSS WITH TWO ROWS OF IOd COMMON WIRE NAILS (148' OIA. X 3') SPACED 6' O.C. 2. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. 2X SCAB (L) (2.0 x L) 24" MAX 24" MIN NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED WHEN OVERHANG HAS BEEN BROKEN OFF. IMPORTANT THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 40') SPACED 24' O.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD LOADS NOT EXCEEDING 50 PSF. TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY. REFER TO INDIVIDUAL TRUSS DESIGN - FOR PLATE SIZES AND LUMBER GRADES