HomeMy WebLinkAboutARCHITECTONIC LETTERArchitectonic Inc RECEIVED February 12, 2019 FEB 2.5 2019 ST. W91c; Ccyncy, rcgrmiFtin9 Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure located at, 5285 Melville Road, Saint Lucie County, Florida SCANNED BY Manufacturer: Extreme Metal Fabricators, LLC St. Lucie County Profiles: 5V Crimp (26 ga. Steel) 24" Wide Roof Panel, FL# 17022.1 Code: FBC 2017; Section R 905 Wind Speed: 160 MPH; Ultimate Design Wind Speeds Exposure: B Mean Roof Height: 25' Maximum Pitch: 6/12 Minimum Required Design Pressure: Zonel: -24 Zone 2: -40 Zone3: -60 Maximum Uplift Pressure: -86 Fasteners: # 9 x 1-1/2" Hex -Washer Head Wood Screw @ 12" o.c. horizontal & 16" o.c. vertical to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (or sufficient length to meet requirements) Underlayment: Polyglass Roof Underlayments, FL# 5259-1128 (self -adhering) Roof Decking: Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank @ 6" O.C. thru out zone 1, 4" O.C. perimeter, and 6" O.C. field zone 2, and 4" O.C. thru out zone 3. FILE COPY The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code, and the pp FLO e� +S^ uA AR 9 98 recommendations. 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1