HomeMy WebLinkAboutPRODUCT REPORTF Palm'City, FL 34990 Compliant with Florida Building Code 2017 (6dr ed.) RECEIVED Compliant with Florida Product Approval Rule # 61G20-3 FEB 2 5 nig Compliant: Keystone Certifications ST. Lucie County, rermltung SCANNED Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec.1507.4.2 BY Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood St. Lucie County Deck w/ min. 0.42 specific gravity with screws. 24" Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/9" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec.1507. see Fastener attachment specfficafions above Install Details: Table A Allowable LoadS METHOD i METHOD 2 METHOD 3 PRESSURE* -86 PSF -93.5 PSF -101 PSF ROWSPACING 16" O.C. 16" O.C. 8" O.C. FASTENER SPACING (ALONG Panel width) 22" o.c. 12" o.c. 12" O.C. NETHODDESIGN FASTENER SIZE #9 i130 #10 Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527 ' UL 580-06 & 1897-041 Test Report D3893.01-450-18 05/02/14 Test Report F3366.01-450-18 12/18/15 TAS 125-03 Test Report •D05893.02-450-18 07/22/14 *EQUSVALEAICr-UL 1697-94 is equivalent to testsrsaodard UL t897 �i�prrrrr "Desl9"Piss"re margin oPsafety2:1 Locke Bowden, P.L does not have, not will acquire a flnan under this evaluation. _Locke Bowden, P.E. is not owned, operated, or controlled report. - - - - - - - - distributing products products under this ,0 ` FL17O22.1 5V Crimp (26GA Steel), 24" Wide Roof Panel - Details Limitations: 1. Undedayment to be compliance with current Florida Building Code (FBC)2017 61h ad. 2. Minimum slope to be compliant with Florida Building Code 2017 601 ad., and per with Manufacturer's Installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w4udsdiction Is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing In compliance w1FBC 2017 6M ad., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. 31T �nvnnue, c Panel Profile o.c. I O.C. Fasten x 12'�Min. or #lox 1-12" Min. per able "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Wdth Panel Refer to Tabte "A" for Spacing Along Panel Overlap Length - — -- — - i Deck 15/32" or greater Plywood, or - Wbod plank