HomeMy WebLinkAboutARCHITECTONIC LETTERArchitectonic Inc February 19, 2019 SCANNED St Lucie Coun Saint Lucie County Building Department FFEB ECEIVED ty Attn: Roof Permit Plan Review 2 6 2019 2300 Virginia Avenue Ft. Pierce, FL 34982 P-PD tiny ST. Lucie County__—_ Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure located at 2322 Oak Drive, Saint Lucie County, Florida Manufacturer: Polyglass USA Profiles: Modified Bitumen Roof System, FL #1654.1, System W-140 Code: FBC 2017; Section R 905.10 Wind Speed: 165 MPH; Ultimate Design Wind Speeds Exposure: C Mean Roof Height: 30' Maximum Pitch: %/12 Required Design Pressure: Zonel: -33.5 Zone 2: -52.8 Zone3: -73.4 ` Maximum Uplift Pressure: -90 psf Roof Decking: Existing 5/8" plywood sheathing to be nailed w 8d x 2" ring shank nails @ 6" O.C. thru out Zone 1, 4" O.C. perimeter & 6" O.C. field Zone 2, and 4" O.C. thru out Zone 3. Base: Polyglass APP Base, OMG #12 Standard Roofgrip or OMG # 14 Heavy Duty with OMG 3" Round Metal Plates of OMG Flat Bottom Metal Plates @ 6" o.c. at min. 4" lap and 6" o.c. at three (3), equally spaced, staggered center rows Ply Sheet: None Cap: APP-TA The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code, and the Manufacturer's recommendations. 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1