Loading...
HomeMy WebLinkAboutAS BUILT CERTIFICATESRECE1yEp� -f Lab Report No. 129994 OCT � 9 2019 t. %�C INDUSTRY LttlOc CC.A. # 30448 Lu"oartme,r `r Lab Certificate # 17-0703.01 )NsrECTIONDATF_- Oetober'l 1, 2019 PERMITNo: CLIENT NAME: Petersen Dean PROPERTYADDREW 8407iWinter Garden Pkwy, Fort Pierce AS ,BUILT CERTIFICATE HOME OWNER: Andres Alvarez SCANNED BY St. Lucie County Our office inspectedth1.e above referenced roof. The roof was exposed to verify proper installation. During this inspection the following Components were verified: ® Metal Panel Metal Panel: Englert Series 110124-ga6ee-steel 16" width panel fastened at 6" o.c. throughout, according to Method 1 011698.6 R4, page 5) To the best of my knowledge, belief end professional opinion, the above roof installation complies with the minimum requirements as set forth by the Florida Building Code and the approved documents. This report is no to be Construed as a warranty of the roof, only the representation of the actual conditions at the time of inspection. This report cannot reasonably encompass the entire roof installation and therefore, the presented information s'based specifically on the areas inspected. Do not hesitate to call my office .with any questions. Jorge GkhWez, P.E. Lie. 0.3 4 10735 SW 216w 5t. Unit 404 Page 1 of i Tel: 305-256-4550 Miami FL33170 www.FloridaTEt-net Fax:30S-256-6833 1-11 UL 05Yy Lab Report No. 129994 OCr29T019 permtttln n _.. ROOFING INDUSTRY 7NSPECHONDATE: October 1142019 PERMIT C.A. # 30448 Lab Certificate # 17-0703.01 CLIENTNAME: Petersen Dean HOME OWNER• PROPERTYADDRE . SW%Vinter Garden PL-wy.,.Fort Pierce REPRESENTA=- Andres Alvarez SCANNED AS 4V;LT CERTIFICATE BY St. Lucie Count, Our office inspected"the above referenced roof. The roof was exposed to verify proper installation. During this inspection the following components wem verified. ® Metal Panel Metal Panel: Englert Series 110124*ge steel 16" width panel fastened at 6" o.c. throughout, according to Method 1 (FI:11698.6 R4rpage S) To the best of my lmowledge,lbelief and professional opinion, the above roof installation complies with the minimum requirements as, $et forth by the Florida Building Code and the approved documents. This report is no to be construed as a warranty of the roof, only the representation of the actual conditions at the time of inspection. This report cannot reasonably encompass the entire roof installation and therefore, the presented inforplation is based specifically on the areas inspected. Do not hesitate to call my office with any questions. CONTRACTOR COPY rm 10735 SW 21611 St. Unit 404 Page i'of i Tel: 305-256-4550 Miami Fl-33170 WWW.FIo[idaTEC,net Fax:305-256-6833