HomeMy WebLinkAboutNOA"� MIAMI-DADE COUNTY
MIAMMDADE PRODUCT CONTROL SECTION
c- - - 11805 SW26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DMSION T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www miamidadc eov/cconomv
GAF- FILE COPY
1 Campus Drive Parsippany, NJ 07054 � ` l b 2- � �BY SCANNED
SCOPE: " St. Lucie County
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA-shall not lie valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County)andlor_the_AHL(in`areas other than Miami Dade County) -reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer -will incur the expense of such testing and the AHJ may immediately revoke, modify, or -
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is -determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This -product -is -approved as described herein; and has been designed -to comply"_with the Flbrida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: VersaShield® Fire -Resistant Roof Deck Protection and VersaShield® Solo— Fire -Resistant
Slip Sheet
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city,'state and following '
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials; use, and/or manufacture of-;the;product or process. Misuse of this NOA as an endorsement of any product, -
for sales,adveaWng or-any_other purposes -shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and -removal of NOA. - - -------- --- -- -----•---
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety. -
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No_14-1022.26 and consists of pages 1 through 3.
The submitted documentation was reviewed by Alex Tigera.� �»
MIAMFDADE COUNTY
J NOA .No.:16-1216.02
• • • • i Expiration Date: 02/07/22
Approval Date: 02/02/17
Pagel of 3
ROOFING ASSEMBLY APPROVAL
Category: _ Roofing
Sub -Category: Underlayment
Material: Fiberglass
SCOPE:
This acceptance is for VersaShield® Fire -Resistant Roof Deck Protection (a.k.a "VersaShield® Urderlayment") and
VersaShield® Solo— Fire -Resistant Slip Sheet (a.k.a "VersaShield Solo-"), as described in this Notice of Acceptance,
for use with approved prepared roof assemblies. Designed to comply with the Florida Building Code and the High -
Velocity Hurricane Zone of the Florida Building Code.
PRODUCT DESCRIPTION:
Manufactured by
Applicant Dimensions
VersaShield® Fire- 42" x 100'rolls
Resistant Roof Deck
Protection
VersaShiel10 Solo'T^(--- 72"'x 1"667-=rollsw�-
Fire-Resistant Slip Sheet 36, )C1'66.7' rolls
MANUFACTURING LOCATION:
1. Conover, NC
Test
_."= Product
Specifications
Descrintion
ASTM D 226
Non-Asphalticfiberglass-based underlayment
Type II
and/or fire barrier.
UL790 —Non-Asphaltic fiberglass -based slipsheet and/or
fire barrier.
EVIDENCE SUBMITTED:_
-
Test AQehey
Test Identifier
PRI Construction Materials
GAF-270-02-02
Technologies _
GAF-748-02-01
ELK-063-02-01
Underwriters Laboratories Inc.
99NK45831
1ONK11990
_ R19254
--,
— 08CA37926
- -- ' - --
-" 08CA49140
TestName/Report
Date
ASTM D 226
11/15/10 - -
ASTM D 226
12/12/16
TAS 100
09/27/O1
UL790
03/21/00
UL790
05/18/11
ASTM D 226
09/13/01
UL790
09/23/09
INSTALLATION:
1. _VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® Solo- Fire -Resistant Slip Sheet shall be
installed in strict compliance with applicable Building Code.
2. VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® Solo Fire -Resistant Slip Sheet shall be
installed with a minimum 4-inch head lap in a shingle layer fashion.
3. VersaShield® Fire -Resistant Roof Deck Protection shall be mechanically fastened with approved fasteners in
compliance with Florida Building Code 1518.2 when used in lieu of a code prescribed ASTM D_226 Type II
underlayment.
MIAMFDADE COUNTY _ - NOA No.: 16-1216.02
..., i - Expiration Date: 02/07/22
Approval Date: 02/02/17
Page 2 of 3
LIMITATIONS:
1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials -Directory for fire
ratings of this product
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.
3. VersaShield® Fire -Resistant Roof Deck Protection shall not be left exposed as a temporary roof for longer than 30
days of application. VersaShield® Solo- Fire -Resistant Slip Sheet shall not be left exposed to the weather.
4. VersaShield® Fire -Resistant Roof Deck Protection and VersaShield® Solo- Fire -Resistant Slip Sheet are a
component used in roof assemblies. Roof assemblies are approved under specific assembly Notice of Acceptance.
5. VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® SoloT Fire -Resistant Slip Sheet may be used
with any approved roof covering Notice of Acceptance listing. VersaShield® Fire -Resistant Roof Deck Protection
or VersaShield/ SoloTmFire-Resistant Slip Sheet may be used as a component part of an assembly in the Notice of
Acceptance. If VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® Solow Fire -Resistant Slip Sheet
�-is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product
Control Department -for approval'provided that appropriate documentation is provided to detail compatibility of the
products, wind uplift resistance, and fire testing results.
6. VersaShield® Fire -Resistant Roof Deck Protection and VersaShield® Solo- Fire -Resistant Slip Sheet are a non -
asphaltic underlayment that may -be -used as a fire barrier for prepared roof assemblies. For fire classification of
specific roofassemblies using VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® Solo- Fire--
--- - _ -- -Resistant Slip Sheet refer to a current Approved Roofing Materials Directory for fire ratings of this -product.
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
. Rule 61 G20-3 of the Florida Administrative Code.
LABELING:
All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's'name or logo, -city and
state of manufacturing facility, yellow line to identify. the ASTM Standard designation or logo, and the following-"
statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as
- shown below.w�
MIAMI•DADECOUNTY
_- BUILDINGyPERMIT-REQUIREMENTS:
- = Application for building permit shallbe accompanied by copies of the following:
1. This-Noticeof-Acceptance.—
oth—=
2. Any-er-documents required by Building Official or Applicable building code in order to properly evaluate the
installation of this material.
END OF THIS ACCEPTANCE
- - NOA No.: 16-1216.02
-- Expiration Date: 02/07/22
Approval Date: 02/02/17