Loading...
HomeMy WebLinkAboutTRUSS PAPERWORKWARNING* F11,57 A PLACEMEN I PLAN FOR ENGINFFREU -BRACING: -SEE FINAL ENMNEERING SHEETS FOR THr -BACK CHARGES WILL NOT BE ACCEPTED UNLESS OUR LL BEARING POINTS MUST BE COMPONENTS AS DEFINED BY WTCA 1 - 1995. 1) FOR THE ERECTION BRACING FOLLOW STRUCTURAL DATA, NUMBER OF GIRDER AND TRUSS DESIGN DEPARTMENT APPROVES THEM IN ADVANCE DIAPHRAMS HAVE NOT BEEN ANALYZED BY NSTRUCTIONS ON THE BCSI-B1 SUMMARY SHEETS PLIES AND THE CONNECTION INFORMATION. ALL HANGERS ARE SIMPSON STRONG -TIE UNLESS NSTALLED PRIOR TO INSTALLING EAST CAOST TRUSS. 2) PERMANENT BRACING FOR THE STRUCTURE IS HE OUR DESIGN DEPARTMENT MUST APPROVE OTHERWISE NOTED. INSTALL HANGERS ACCORDING NY TRUSSES! FOR ERECTION AND INSTALLATION OF TRUSSES RESPONSIBILITY OF OTHERS. ALTERATIONS AND/OR REPAIRS TO TRUSSES IN TO THE CURRENT SIMPSON STRONG -TIE CATALOG FAILURE TO DO SO MAY RESULT FOLLOW INSTRUCTIONS ON THE BCSI-B1 SUMMARY 3) INSTALL WEB BRACING AS STATED ON SEALED ADVANCE, N DAMAGED TRUSSES AND WILL VOID ALL WARANTIES, I SHEETS AND SEALED ENGINEERED TRUSS DRAWINGS FENGINEERING TRUSS DRAWINGS. 12' 8" f 02 E i i A A 03 x. x A04 - - - -- ------ - -- B01 BY01 IERB01 `r W o BYO R B01 Qo - ol BYO B01 1913 1 /2" - B02 ////77771=A1!! _ o B03 N 1' " 0 0 B03 `� o B03 6' 2" 8t " 62" o 0 b m B03 EXISTING TRUSSES 12' 4" 7t 4" 20' 4" 401011 CEILING LEGEND 3/12 SLOPE CLG I I I Ii i 1 FLAT IT-0" CLG FLAT 10'-0" CLG f i s • : F���������������T '► EXISTING: VERIFY ALL CONDITIONS, PITCH, HEEL & DIMENSIONS IDITION NOTE: IS THE BUILDERS RESPONSIBILITY TO ;RIFY ALL EXISTING CONDITIONS, ECT ►NNOT BE RESPONSIBLE FOR MATCHING ]STING ROOF CONDITIONS. 'ON SIGNING, BUILDER AGREES TO ALL )NDITIONS AS SHOWN ON THIS LAYOUT TRUSS CONNECTORS TO EXISTING ARE BY OTHERS HAND FRAME AROUND CEILING TRANSITIONS MAY BE REQUIRED r:*NI FILE Copy M•0 -puss S"_STE+S ?CDLC-S EAST COAQ.T TRUSZ 5285 FT, LUCIE EI VD. FT, PTERCE FL, 34946 OFFICE: 1772)466-2480 FtLT: (772)466-5336 USTOMER:Telese Builders )B NAME: MARSH LANDINGS FIRE JOB DDRESS:7311 MARSH TERRACE ITY/COUNTY:PSL # J37365 )DEL:THE RESERVE @PGA ,RAGE FT 531 TE 2/18/19 ILA iES I 61GiSS-31.003 (3) (c). FAST COAST TRUSS u the "Treat Deane F.&nne" Trmen arc deaiped in accordance with the Florida Mldi.g Code By approving this placement plan(s), ]natured anywhere on this sheet, the customer his representitive acknowledges that this ]cement plan complies with the structural intent the project. The customer also acknowledges that this )proval authorizes EAST COAST TRUSS to anufacture these trusses and deliver them to e project indicated on this drawing. The customer also acknowledges that he/she :cepts financial responsibility for any repair, igineering, and labor required due to errors her than those of EAST COAST TRUSS. ned: Date: = FBC2017ITP12014 ASCE 7-10 GN CRITERIA =MWFRS UPANCY CATEGORY= II )SURE =B SPEED =160 DING TYPE =ENCLOSED V HEIGHTAF FLOOR: DUR FACTOR= PSF=TCLL-TCDL-BC LL-BC DL DUR FACTOR=1.25 TCDL-BCLL-BCDL "NON -CONCURRENT BC LL 10psf CONCURRENT BC STORAGE LL 20 psf MWF = MAIN WIND FORCE C&C = COMPONENTS AND CLADDING TOB = TOP OF BEARING TC = TOP CHORD BC = BOTTOM CHORD LL = LIVE LOAD DL = DEAD LOAD psf = POUNDS PER SQUARE FOOT # = POUNDS UNLESS SHOWN ON ENGINEERED TRUSS DRAWING. ALL GIRDER/COLUMN LOADS MUST BY-PASS FLOOR TRUSS UNLESS SHOWN ON ENGINEERED TRUSS DRAWING. RECOMMENDED ON FLOOR TRUSSES SPANNING 20-Ou OR MORE BE SET WITH A SPREADER BAR. THE kDER BAR SHOULD BE AT LEAST 1/2 IN LENGTH AS THE SPAN OF THE TRUSS VG SET. TO BCI-B1 FOR COMPLETE ON AND SAFETY PROCEDURES. SUPPORT ANY PLANT SHELVES 9 DZ - REVISED PER FIELD VERIFIED SCANNED BY St. Lucie County it Id Q Z LL 0 75 U) W J Z Z) O W U) Feen Z ❑• TRUSS PLACEMENT PLAN