Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405 FLORIDA E ENERGY EFFICIENCY CODE FORX1&JZCQUCX1ON Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: JAAR ENTERPRISES Builder Name: JAAR ENTERPRISES, LLC. RECEIVED 'u4eeL' 5809 SPRUCE DRIVE Permit Office: ST LUCIE COUNTY Oty, State, Zip: FORT PIERCE, FL, 34982 Permit Number: iq 02 - Dy79 APR 0 81019 owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2) Permitting Departm St. Lucie County 1. New construction or eAsting New (From Plans) 9. Wall Types (1747.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- E)d Insul, 6derior R=4.1 1499.06 ft' b. Frame- Wood, Adjacent R=11.0 248.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1781.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 1781.00 ft2 6. Conditioned floor area above grade (ft2) 1781 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft 11. Ducts R ft' 7. Windows(216.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 140 a. U-Factor: Sgl, U=0.65 216.33 112 SHGC: SHGC=0.25 b. U-Factor: NIA ft2 12. Cooling systems kBtulhr Efficiency SHGC: a. Central Unit 30.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtulhr Efficiency J. U-Factor. N/A ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.500 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (1781.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1781.00 ft' b. Conservation features EF: 0.980 b. N/A R= ft2 None - c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.121 Total Proposed Modified Loads: 62.22 PASS Total Baseline Loads: 63.12 1 hereby certify that the plans and specifications covered by Review of the plans and IT Spgl� this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARE BY: Before construction is Completed DATE: this building will be inspected for a a _ compliance with Section553.908 .. I hereby certify that this building, as desig ad, is in compliance Florida Statutes. 1,1Al with the Floridaorida Ener�e. -COP �,�0 OWNER/�)C T /T BUILDING OFFICIAL: DATE: ��R� DATE: Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance With R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). SCANNED BY §t: Lucie County 11/28/2018 8:52 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 6 ttt FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT _ Title: JAAR ENTERPRISES Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1781 Lot # Owner Name: Total Stories: 1 Block/SubdMsion: tof Units:. 1 _ -Worst Case. No PlatBook: - Builder Name: JAAR ENTERPRISES, LLC. Rotate Angle: 0 Street: 5809 SPRUCE DRIVE R�ermit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jyrisdictton: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, 34982 New/Ebsting: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1781 19328 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 2 188 1504 No 0 1 1 Yes Yes Yes 2 CLST 2 20 160 No 0 1 Yes Yes Yes 3 BATH 2 50 400 No 0 1 Yes Yes Yes 4 CLST 3 20 160 No 0 1 Yes Yes Yes 5 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes 6 LIVING ROOM 300 4200 No 0 1 Yes Yes Yes 7 FOYER DINING RO 240 3360 No 0 1 Yes Yes Yes 8 NOOK 130 1820 No 0 1 Yes Yes Yes 9 KITCHEN 130 1820 Yes 0 1 No Yes Yes 10 LAUNDRY 70 560 No 0 1 Yes Yes Yes 11 MASTER BEDROO 280 2520 No 0 1 1 Yes Yes Yes 12 M WIC 54 432 No 0 1 No Yes Yes 13 M BATH 109 872 No 0 1 Yes Yes Yes 14 HALL 21 168 No 0 1 No Yes Yes FLOORS # Fluor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 2 27 It 0 188 ft' __ 1 0 0 2 Slab -On -Grade Edge Insulation CLST 2 2ft 0 20 ft' — 1 0 0 ri 3 Slab -On -Grade Edge Insulation BATH 2 5 ft _ _ 01 50 ft' 1 0 0. - 4 Slab -On -Grade Edge Insulation CLST 3 2ft 0 20 ft' __ 1 0 0 11/28/2018 8:52 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST RFPART FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulation BEDROOM 3 26 ft 0 169 ft- __ 1 0 0 6 Slab-Oo-Grade Edge Insulation LIVING ROOM 15 ft 0 300 ft2 1 0 0 _ 7 Slab -On -Grade Edge Insulation FOYER DINING 15 ft 0 240 ft' __ 1 0 0 8 Slab -On -Grade Edge Insulation NOOK loft 0 130 ft- __ 1 0 0 9 Slab -On -Grade Edge Insulation KITCHEN 1 ft 0 130 ft2 __ 1 0 0 10SIab-On-Grade Edge Insulation LAUNDRY 7 ft 0 70 ft2 __ 1 0 0 11SIab-On-Grade Edge Insulation MASTER BEDRO 35 ft 0 280 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulation M WIC 1 ft 0 54 ft2 ___ 1 0 0 13SIab-On-Grade Edge Insulation M BATH 9 ft 0 109 ft2 __ 1 0 0 14SIab-On-Grade Edge Insulation HALL 1 ft 0 21 ft2 __ 1 0 0 ROOF _ / Roof Gable Roof Solar SA Emitt Emitl Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1992 112 0 ft2 Medium 0.6 No 0.9 No 20 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1781 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type _ 1 Under Attic (Unvented) BEDROOM 2 20 Blown 188 ft- 0.1 Wood _ 2 Under Attic (Unvented) CLST 2 20 Blown 20 ft2 0.1 Wood _ 3 Under Attic (Unvented) BATH 2 20 Blown 50 ft2 0.1 Wood _ 4 Under Attic (Ummmed) CLST 3 20 Blown 20 ft2 0.1 Wood 5 Under Attic (Unvented) BEDROOM 3 20 Blown 169 112 0.1 Wood _ 6 Under Attic(Unvented) LIVING ROOM 20 Blown 300 ft2 0.1 Wood 7 Under Attic(Unvented) FOYER DINING 20 Blown 240 ft' 0.1 Wood 8 Under Attic(Unvented) NOOK 20 Blown 130 ft2 0.1 Wood _ 9 Under Attic(Unvented) KITCHEN 20 Blown 130 ft2 0.1 Wood 10 Under Attic(Unvented) LAUNDRY 20 Blown 70 ft2 0.1 Wood _ 11 Under Attic (Unvented) MASTER BEDRO 20 Blown 280 ft2 0.1 Wood _ 12 Under Attic(Unvented) MWIC 20 Blown 54 ft' 0.1 Wood _ 13 Under Attic (Unvented) M BATH 20 Blown 109 ft2 0.1 Wood } 14 -Under-Attic (Unvented)— - - -HALL 20 -Blown 21 ft2 0.1 Wood 11/28/2018 8:52 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N Exterior Concrete Block - Ext Inst8EDROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 - 2 W Exterior Concrete Block - Ext Insd1EDROOM 2 4.1 13 0 8 -0 104.0 ft2 0 -0 0.6 0 _ 3 N Exterior Concrete Block - Ext Insul CLST 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 4 N Exterior Concrete Block - Ext Insul BATH 2 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 5 N Exterior Concrete Block - Ext Insul CLST 3 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 _ 6 E Exterior Concrete Block - Ext InsiBEDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0 7 N Exterior Concrete Block - Ext InsIMEDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0 _ 8 W Exterior Concrete Block- Ext InsJIIVING ROO 4.1 15 0 14 0 210.0 ft2 0 0 0.6 0 _ 9 E Exterior Concrete Block - Ext InsdfOYER DINI 4.1 15 0 14 0 210.0 ft2 0 0 0.6 0 10 W Exterior Concrete Block- Ext Insul NOOK 4.1 10 0 14 0 140.0 ft2 0 0 0.6 0 _ 11 E Exterior Concrete Block - Ext InsuILAUNDRY 4.1 7 0 8 0 56.0 ft2 0 0 0.6 0 _ 12 S Exterior Concrete Block - Ext InsMASTER BE 4.1 17 0 9 0 153.0 ft2 0 0 0.6 0 _ 13 W Exterior Concrete Block - Ext InsMASTER BE 4.1 18 0 9 0 162.0 ft2 0 0 0.6 0 14 S Exterior Concrete Block - Ext Insul M BATH 4.1 9 0 8 0 72.0 ft2 0 0 0.6 0 15 E Garage Frame - Wood M BATH 11 21 8 168.0 ft2 0 0.25 0.600000 0 16 S Garage Frame -Wood LAUNDRY 11 10 8 80.0 ft2 0 0.25 0.600000 0 WINDOWS Orientation shown is the entered, Proposed orientation. _ / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 2 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 1 ft 6 in 1 ft4 in None None _ 2 N 4 Metal Low-E Single Yes 0.65 0.25 N 6.0 ft- 1 ft 6 in 1 ft 4 in None None 3 E 6 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 1 ft 6 in 1 ft 4 in None None 4 W 8 Metal Low-E Single Yes 0.65 0.25 N 60.0 ft2 1 ft 6 in 1 ft 4 in None None _ 5 E 9 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 1 ft 6 in 1 ft 4 in None None _ 6 E 9 Metal Low-E Single Yes 0.65 0.25 N 6.7 ft2 1 ft 6 in 1 ft 4 in None None 7 E 9 Metal Low-E Single Yes 0.65 0.25 N 6.7 ft2 1 ft 6 in 1 ft 4 in None None _ 8 E 9 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft2 1 ft 6 in 1 It 4 in None None _ 9 W 10 Metal Low-E Single Yes 0.65 0.25 N 30.0 112 1 It 6 in 1 ft 4 in None None 10 W 13 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 1 ft 6 in 1 ft 4 in None None 11 S 14 Metal Law-E Single Yes 0.65 0.25 N 12.0 ft2 1 ft 6 in 1 ft 41n None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 462 ft2 462 ft2 31 ft 8 ft 11 11/28/2018 8:52 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION iF Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000483 2254.9 123.79 232.81 .3832 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 30 kBtu/hr 900 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Attic 0.98 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cent # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS / —Supply V # Location R-Value Area Return Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC# Heat Cool 1 Attic 6 140 ft- Attic 14 fP Default Leakage Garage (Default) c(Default) c 1 1 TEMPERATURES Programable[[ Thermostat:x,]N r[X,]] Heating [X] Jan L 1 Feb lnl Mar Venting [ 1 Jan I 1 Feb IXl Mar r Creilli]ing Fans: fX [X] [X� [X [ j AApr l 1 May [ Jun [ ] Jul E ] Aug [ Sep L1 I 1 I Jun [ 1 Jul ] Aug [ Sep lxl Oct X Nov Dec Ir)(') [ ] Decec 11/28/2018 8:52 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 - PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BATH 2 Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Defaull(8 lbs/sq.ft. ft2 ft 0.3 HALLWAY Default(81bs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 lbs/sq.ft. ft2 ft 0.3 PANTRY Default(B lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(B lbs/sq.ft. ft2 It 0.3 GREAT ROOM Default(8 lbs/sq.ft. ft2 ft 0.3 DINING Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(81bs/sq.ft. ft2 ft 0.3 FOYER Default(8 lbs/sq.ft. ft2 ft 0.3 POWDER Default(8 lbs/sq.ft. ft2 ft 0.3 OFFICE WIC Default(8 lbs/sq.ft. ft2 ft 0.3 MTOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft2 ft 0.3 CHANGING ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 M HALL Default(8 lbs/sq.ft. ft2 ft 0.3 M BATH Default(8 lbs/sq.ft. 112 ft 0.3 HER WIC Default(81bs/sq.ft. ft= ft 0.3 HIS WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU 2CLST Default(8 lbs/sq.ft. ft2 ft 0.3 UTILITY Default(8 lbs/sq.ft. ft2 ft 0.3 HALL Default(B Ibs/sq.ft. ft2 ft 0.3 OFFICE Default(8 lbs/sq.ft. ft2 ft 0.3 STAIRS UP Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 lbs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8 lbs/sq.ft. ft2 ft 0.3 CLST4 Default(8 lbs/sq.ft. ft2 ft 0.3 BATH 4 Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM4 Default(8 Ibs/s.ft. ft2 ft 0.3 BONUS Name: Signature(: r� c Rating Compant: Date: 11/28/2018 8:52 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: JAAR ENTERPRISES Builder Name: JAAR ENTERPRISES, LLC. - Street: 5809 SPRUCE DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34982 Permit Number: Y Owner: Jurisdiction: ST LUCIE COUNTY w - Design Location: FL, Fort Pierce = U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERI General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks orjoints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be Installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring at J plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wirin . Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electricallphone box on The air barrier shall be installed behind electrical or communication extedorwalls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover Plates and walls or ceilings. — — m my wmis sma be in accordance with the provisions of IGC.-4uu. 11/28/2018 8:52 AM EnergyGauge@ USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 30.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1781 d) Room unitIPTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 27.0 c) Area 7c. 216.3 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) Be. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1081. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 20.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit 0 Programmable thermostat No `Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 5809 SPRUCE DRIVE City/FL Zip: FORT PIERCE, FL 34982 11/28/2018 8:52:40 AM EnergyGauge® USA 6.0.02 - RaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 wrightsoft° Project Summary Date: NOV.28,2018 Entire House ey: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-4666799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM Prooect Information For. JAAR ENTERPRISES, JCAND SONS HOME BUILDERS, INC. 5809 SPRUCE DRIVE, FORT PIERCE, FL 34982 Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19996 Btuh Structure 22263 Btuh Ducts 4736 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24732 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 21150 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3890 Btuh Ducts 1847 Btuh Central vent (0 cfm) 0 Btuh Heatingg Area Cool (none) (ft� 1780 1780 Equipment latent load 5737 Btuh Volume (ft� 19320 19320 Airchanges/hour 0.38 0.20 Equipment Total Load (Sen+Lat) 26887 Btuh Equiv. AVF (cfm) 122 64 Req. total capacity at 0.70 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Rheem Trade Trade RHEEM Model Cond RA1630AJlNA AHRI ref Coil RH1T3621HTANJA 8080143 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 7.0 kW Sensible cooling 21000 Stuh Heating output 23981 Btuh Latent cooling 9000 Btuh Temperature rise 22 OF Total cooling 30000 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.040 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat._ —Load sensible heat ratio 0.80 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed �:- wrPg�F•tlsoft` 2018-Kbw2808:55:46 "R ENTERPRISE- 809 S RUCE DUhilhamal 2018 1 Cale RSU08101 Page 1 ...hlsoft FNAC\JAAR EMERPRISE- 5809 SPRUCE DR.mp Cale -MA MJB Front Daor faces: E wrightsoftRight-A) Worksheet Job: Entire House Date: NOV. 28, 2018 QUICK CALCS, INC. By: 317 ST LUCIE LANE. FORT PIERCE, FL 34946 Phone: 7724666799 Fax 772466.6796 Email: QUICKCALCSQA.OL.COM 1 2 3 4 5 Room name EVOsed Wall -Room height Room dinensions Roan area Entire House 153.0 R 10.9 it 1780.0 ft' BEDROOM 2 27.0 ft 8.0 It heat/cool 1.0 x 185.0 ft 186.0 ft' Ty Constmctiw number U-veWe (BtUVttk'F) Or HTM (BtulM Area (115 or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Bluh) Heat Cool Gross N/P/S Heal Cod Gross N/PIS Heat Cool 6 11 V7✓-' 13A-4acs 2 glazing, Ur.lw✓:e__ 13AAccs 2 glazing, Ur loot 2 glazing, Ur Im-e 2 glazing, Ur love 2 alazlno. Ur love _ '13A4acs 2 glazim clr.lov - 13AAcrs 2 glazing, clr loWe 2 glazing, clr lcw a 2 glazing, Ur loW-e_ 16A$Oad 22A-tph -0143 _0.580 0.143 0.580 0.580 0.580 _0.580 0. 143 -0.580 0.143 0.580 0.620 0.650 _0.032 n __n_ a a a a _e_ 5 _s_ w w w w 4A0 _16.24 4.00 16.24 16.24 16.24 16.24 4.00 __16.24 4.00 16.24 17.36 18.20 0.90 219 __13.73 219 31.76 31.76 31.76 31.76 ^ 219 -13.73 219 31.76 30.44 29.93 =2.24 288 _ 6 370 45 6 7 _ 20 225 2 616 30 30 61 =780 1780 - 282 __0 292 0 0 0 _ 0 _ -213 -24 496 0 0 0 _1780 153 1129 _97 1167 731 101 110 _331 --853 -195 -817 __.82 638 1429 198 216 648 - 466 165 `"`-112 --0 0 0 0 0 0 ---0 -0 112 " 448 _,0 0 0 0 0 0 -"-245 Iw - __0 0 0 0 0 0 --- 0 __0 ____.0 0 0 0 0 0 -�0 --.0 W, _ C w C - F 0 -0 1981 457 521 1114 =1595 5818 1083 953 913 1832 -3987 0 104 15 0 0 = 188 188 89 0 0 0 =88 27 356 244 0 0 =68 1027 195 476 0 0 = 421 0 1.358 38.02 0.00 6 c)AED mursim 315 82 Fslvelope loss/gain 16231 13542 2244 1419 12 a) Nfdtretion h) Room ventilation 3765 0 1062 0 543 0 153 0 13 ORernal gains; Occupants @ 230 Appliances/other 2 460 7200 0 0 500 Subtotal(lines 6to 13) 199% 22263 2786 2072 14 15 Less e:demal load Less transfer Redistribution Subtotal Ductlbads - - _- 24% 00/0 0 0 0 19996 4736 0 0 0 22263 0 24% 01. 0 0 ill 2897 686 0 0 54 2127 0 Total room load Air required (cfm) 24732 1000 22263 1000 3584 145 2127 96 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed A. wrlgAtsoTt� 2018-tbw2808:55:46 Right -Suite® Universal 2018 18.0.31 RSU08101 Page 1 ...htsod HVACWAAR ENTERPRISE- 5809 SPRUCE DR.rup Calc = MJB Front Door faces; E wrightsoft Right-M Worksheet Job: Entire House Date: NOV. 28, 2018 QUICK CALCS, INC. By. ' 317 ST LUCIE LAINE, FORT PIERCE. FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM 1 ..2 3 4 5 Room name Exposed wall Room height Roan dimensions Room arm CLSr 2 2.0. ft 8.0 ft head/cool 10.0 x 2.0 It 20.0 It' BATH 2 5.0-ft 8.0 It heat/cod 10.0 x 5.0 ft 50.0 ft' Ty construction number U-xelue (BtWft''F) Or HTM (etuhrft') Area iit� or perimeter (ft) Load (Btuh) Area or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cod 6 11 13A4 2glazing„dr.Icwe__ 13A4ocs 2 glazing, dr lcw-e 2 glazing, dr love 2 glazing, dr lov 2 plm no -v cIr lw_e "13A4ocs 2glaziog,.dr.lex-e_ --0.143 __0,580 0.143 0.580 0.580 0.580 0.580 -0.143 -.0.580 n _n_ a a a a a s _s_ 4.00 16.24 4.00 16.24 16.24 16.24 16.24 d00 _-16.24 2.19 _13.73 219 31.76 31.76 31.76 31.76 219 _13.73 18 0 18 -__0 0 0 0 0 0 64 __0 0 0 0 0 0 -0 -_D ---35 40 e.,__8 0 0 0 0 0 -34 0 0 0 0 0 0 ---136 _97 0 0 0 0 0 --74 _82 0 0 0 0 0 0 -0 W 0 0 0 0 0 _0 0 0 0 0 0 0 -0 0 0 0 _-0 0 --0 0 0 0 __0 W --G FL----(Gi 13A-4= 2glazing, dr lox-e 2 glazing, dr low-e 2 glazing, dr hue ,16430ad ' 22A-tph y 0.143 0.580 0.620 0.650 _0:032 1.358 w w w w 4.00 16.24 1T36 18.20 - d,90 38.02 219 31.76 30.44 29.93 =224 0.00 0 0 0 0 20 20 0 0 0 0 : _20 2 0 0 0 0 =18 76 0 0 0 0 --=45 0 0 0 0 =50 50 0 0 0 0 --50 5 0 0 0 0 = a5 190 0 0 0 0 =12 0 ;C= F 0 _ 6 cj AED.=ion -5 -17 Envelope loss/gain 158 75 468 252 12 a) InOttmtion b) Room ventilation 40 0 11 0 100 0 28 0 13 trM1emal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (fines 6 to 13) 198 86 569 280 14 15 Less edema] load Less transfer Rediistrilxltion Subtotal Duolloads 24% 0% 0 0 -198 0 0 0 0 -66 0- 0 249% 0% 0 0 194 763 181 0 0 94 374 0 Total room load Air required (cfm) 0 0 0 0 944 38 374 17 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed 2018-1\1oV2808:55:46 Reek - RigWfluite® Uilwrsal 2018 18.0.31 RSU08101 Page 2 ... htsoll FNACWAAR ENTERPRISE- 5809 SPRUCE DR.mp Celc-MJ8 Front Door faces: E ►}i wrightsoft Right-JO Worksheet Job: Entire House Date: NOV.28, 2018 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-4666799 Fax 772-4666796 Email: QUCKCALCS@AOL.COM 1 .2 3 4 5 Room name Eqosed wall Room height Room dimensions Room area CLST 3 2.0 ft 8.0 It heat/cod 10.0 x 20 ft 20.0 ft' BEDROOM 3 26.0-ft 8.0 It heat/coot 13.0 x 13.0 ft 169.0 It, Ty Construction number U-%elue (BtutVfti-F) Or HTM (Btuh/ft5 Area (ft� or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Btuh) Heat Cool Gmss WP/S Heat Cool Gross WP/S Heat Cod 6 11 %t W 13A455s - 2.glazing, drlove.,. 13A4ocs 2 glazirg, clr loxes 2 glazing, clr Iowa 2 glazing, clr lox -a 2 glazing. clr Iowa 13A4= __ _ glazirg,.ciclowe- 13A4ocs 2 glazing, clr lace 2 glazing, dr tome 2 glazing, dr lave _164-30atl 22A-tph --0.143 �0.580 0.143 0.580 0.580 0.580 ^,0.580 0.143 -0.580 0.143 0.580 0.620 0.6w = g032 1.358 n _n_ a a a a e_ s _s_ w w w w - 4.00 16.24 4.00 16.24 16.24 16.24 16.24 4.00 -16.24 4.00 16.24 17.36 18.20 `0.90 38.02 --2219 __13.73 219 31.76 31.76 31.76 31.76 219 _13,73 219 31.76 30.44 29.93 2-24 0.00 V 16 0 --16 ___ 0 0 0 0 0 0 -_-0 --0 0 0 0 0 ;_20 -64 -35 __0 0 0 0 0 0 - -0 _._ o 0 0 0 0 _45 -104 __0 104 15 0 0 0 104 _ 0 -416 - 228 _0 195 476 0 0 0 . �0 T.0 0 0 0 0 - 379 0 0 0 0 0 0 0 _0 0 0 0 0 20 '20 _0 0 0 0 0 0 --0 __0 0 0 0 0 �18 89 0 0 0 0 ..,0 -_0 0 0 0 0 -169 25 _0 356 244 0 0 0 - -0 __0 0 0 0 0 �151, 989 U�! .C- F 0 __0 0 0 0 0 � 169 169 = 2 76 0 61 c)AEDe ursim _5 -98 Fmelope loes/gain 158 75 2156 1179 12 a) Inrilbation b) Rcomeemilation 40 0 11 0 522 0 147 0 13 internal gains: Occupants @1 230 Appliwreslother 0 0 0 0 0 700 Subtotal (lines 6 to 13) 196 86 2679 2025 14 15 Less wdemal load Less transfer Redistdbution Subtotal 24% 00/. 0 0 -198 0 0 0 0 -85 0 0 24% - 0% 0 0 102 2781 659 0 0 50 2077 0 _ _ _ boot loads Total man Intl Air required (cfm) 0 0 0 0 3440 139 2077 93 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed -rid-wrlgtiisoft� 2018-W 2809:55:46 AM Right -Suite® U IWMal 2018 18.0.31 RSW8101 Page 3 ...htsoft HVACWAAR ENTERPRISE- 5809 SPRUCE DR.wp Calc - MJ8 Front Door faces: E wrightsoft Right-J(R) Worksheet Job: Entire House Date: NOV. 28, 2018 QUICK CALCS, INC. By. 317 ST LUCIE LANE. FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: OOICKCALCS@AAOL.COM 1 . 2 3 4 5 Roamname Elyosed wall Room height Room dimensions Room area LMNG ROOM 15.0 ft. 14.0 ft heaticool 16.0 x 20.0 it 300.0 ft2 NOOK 10.0 it 14.0 it heal/ccol 10.0 x 13.0 ft 130.0 ft2 Ty Construction number U-value (BtutVftx°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft) or perimeter (ft) Load (Btuh) Heat Cool Gross NIP/S Heal Cod Gross N/P/S Heat Cod 6 11 glazing, dr,loµe_ 13A4acs 2 glazing, cir Im" 2 glazing, dr lo%f 2 glazing, dr low-e 2 nlazina. 4r Ioµe_ 13A4ccs 291azing,.dr.lava_ 13A4acs 2 glazing, dr lcx a 2 glazing, dr lov-e 2 glazing, cir lom-e 18A305d-_ 22.4-tph ---0.143 0.580 0.143 0.680 0.580 0.580 0.580 -0.143 .0.580 0.143 0.5ti0 0.620 _ 0.650 _OA 1.358 n _n_ a a a a a s _s.. w w w w =_ 4.00 __16.24 4.00 16,24 16.24 16.24 16.24 - 4.00 16.24 4.00 16.24 17.36 18.20 _32 _. 0:90 38.02 '-219 _13.73 219 31.76 31.76 31.76 31.76 219 � 13.73 219 31.76 30.44 29.93 =224 0.00 0 0 0 0 0 0 0 0 --0 M_-0 -.-. - -0 w ,0 0 0 0 0 0 -. -0 --.0 210 0 0 61 _=300 300 0 0 0 0 0 --U _.0 149 0 0 0 7=300 15 0 0 0 0 0 0 0 0 0 0 '_ _ 0 �0 326 0 0 1832 =-- 0 -_0 0 0 0 0 0 --- -0 _0 ...--_0 140 0 30 0 _130 130 _,A 0 0 0 0 0 �...__0 0 0 0 0 0 --_0 __0 440 0 521 0 =16 380 _0 0 0 0 0 0 ___ _0 _..__0 241 0 913 0 -_--291 -W, �G w I--G IL-CG F 0 �0 596 0 0 1114 P269 570 -0 0 110 0 0 0 ��130 _672 10 --0- 6 c)AED excursion 438 - _ 271 Envelope loss/gain 2549 3267 1458 1716 12 a) Infiltration b) Rcom ventilation 527 0 149 0 352 0 99 0 13 Interval gains: Occupants cQ 230 Applianceslother 0 0 1500 0 0 0 Subtotal (lines 6 to 13) 3076 4916 1810 1815 14 15 Less ademal load Less transfer Redstribullm Subtotal 0% 0 0 4 3080 730 0 0 10 4926 0 249% 0% 0 0 0 1810 429 0 0 0 7815 0 _ Duct loads 241% Total room load Air required (rim) 3810 154 4926 221 7138 80 1815 82 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed -pi- wrigtibotFt[- 2018 N1% -28 08:55:46 Right -Suite® Universal 2018 18.0.31 RSU08101 Page 4 ...hisoe I-MACWAAR ENTERPRISE- 5809 SPRUCE DR.rup Calc = MJ8 Front Door faces: E wrightsoftRight-M Worksheet Job: Entire House Date: NOV. 28, 2018 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM 1 ._2 3 4 5 Room name Exposed wall Room height Roan dimension Room area KfTCHEN 0-ft 14.0 ft he_aticool 10.0 x 13.0 It 130.0 ft. LAUNDRY - 7.0 ft 8.0 ft heat/cool 7.0 x 10.0 It 70.0 ft2 Ty Construction number U-value (Btuh/WF) Or HTM (BtuWft) Area (ft' or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Stuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 11 WW,, 13A4 oci s ---. 2 glazinig, dr,loxe_ 13A4acs 2 glazing, dr lov-e 2 glazing, dr lovv-e 2 glazing, clr love 2 glazing Gr ION a 13A4abs 2 glazirg;.cldowe- 13A4ccs 2 glazing, clr love 2 glazing, clr lo4+e 2 glazing, dr Iowa .16A-30ad 22A-tph _-0.143 _0.580 0.143 0.580 0.580 0.580 ,0.580 0.143 __0.580 0.143 0.580 e620 0.650 _Q032 n _n- a a a a _e s _.s_ w w w w ._ - 4"00 _ 16.24 4.00 16.24 16.24 16.24 16.24 '- 4.00 _.16.24 4.00 16.24 17.36 1820 _ 0.90 38.02 219 _13.73 219 31.76 31.76 31.76 _31.78 -218 _ 13,73 219 31.76 30.44 29.93 _224 0.00 --.."-0 _____0 0 -_._..-.__0 0 -..-.-0 0 --0 -.-0 __0 56 0 0 0 __0 0 -0--0 _--0 -__0 224 0 0 0 0 -_--0 W _.._0 0 0 0 0 0 -0 --0-0-0 0 0 0 0 0 �130 130 0 0 0 0 0 0 0 0 0 0 -_0 0 0 0 0 0 �-0 ---0 0 0 0 0 -291 0 56 0 0 0 0 ..__0 123 0 0 0 0 ^ 0 --0 W 'C _ F 0 ___.0 0 0 0 0_ -=130 0 0 --_0 0 0 0 0 _ v=116 0 0 --0 0 0 0 0_ -70 70 0- 0 0 0 0 =7.0 7 0 0 0 0 __63 266 0 0 0 0 __ _ �157 0 1.358 61 c)AED excursion -132 -76 Envelope loss/gain 116 159 553 203 12 a) Infiltration b) Roornvemilation 0 0 0 0 141 0 40 0 13 Imemal gains: Occupants @ 230 Appliarceslother 0 0 2000 0 0 1000 Subtotal (lines 6 to 13) 116 2159 694 1243 14 15 Less eldemal load Less transfer Redistribution Subtotal _ _ _ Duct loads 0% 0 0 0 116 28 0 0 0 2159 0 24% 00% 0 0 0 694 16 4 0 0 0 1243 0 24% Total faun load Air requined(cfm) 144 6 2159 97 858 35 1243 56 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -rw wrlghbo'tt- 2018-Nov-2808:55:46 Right -Suite® Universal 2018 18.0.31 RSU08101 Page 5 ...htsoft WACWAAR ENTERPRISE- 5809 SPRUCE DR.wp Cale - MJB Front Door faces: E wrightsofC Right-l®Worksheet Job: Entire House Date: NOV. 28, 2018 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-4666799 Fax 772466-6796 Emil: OUICKCALCS@AOL.COM 1 .2 3 4 5 Room name Enyosed wall _ Rom height Room cflmrnslcrs Room area MASTER BEDROOM 35.0 It 9.0 ft heat/cool 1.0 x 280.0 It 280.0 ft' M WIC 0 ft 8.0 ft heat/cod 6.0 x 9.0 ft 54.0 ft' Ty Cmstmotim number U-%due (Btut✓ftMF) Or HTM Area (ft� or perimeter (ft) Load (Btuh) Area (ft5 a perimeter (ft) Load (Btuh) Heal Cod Gross N/RIS Heat Cool Gross NIPIS Heat Cool 6 11 HN- L-C 134-0acs -' 2glaiing,dr.lovicee 13A-0acs 2 glazing, dr Iowa 2 glazing, dr to - 2 glazing, clr Iox-e 2 gl.ina._dr Iowa_ 2 glazing,.dnlowe_- 0,143 -0.580 0143 0.580 0.580 0.580 0.580 �0.143 _____0.580 n _n_ a a a a a ^s -s_ 4.00 _16.24 4.00 16.24 1624 16.24 16.24 4.00 _16.24 -219 _13.73 219 31.76 31.76 31.76 __ 31.76 219 _13.73 0 0 - 0 0 0 0 -`�0 --0 g -'-0 0 ---o -_0 0 0 0 0 0 ----o _-0 0 0 0 0 0 --0 a0 0 0 0 0 0 153 -0 0 0 0 0 0 0 0 0 0 0 __-0 0 0 0 0 0 335 o 0 0 0 0 0 _.__._ 0 ._,_a 0 0 0 0 0 IWI �13A-4acs 153 �-_0 613 _0 0 __0 0 -0 w I--G I`-GG C= F 13A4o 2 glazing, dr Iov a 2glazing, dr 10 2 glazing, cir Iowa i89N0ad 22A-tph 0.143 0.580 0,620 0.650 ''0.032 1.358 w w w w 4.00 16.24 17.36 1320 d90 31102 219 31.76 30.44 29.93 224280 0.00 162 15 0 0 260 147 0 0 0 �280 35 589 244 0 0 ;251 1331 322 476 0 0 _^827 0 0 0 0 0 _ 54 54 0 0 0 0 _54 0 0 0 0 0 _ 48 0 0 0 0 0 _72'I 0 = _ - 6 c) AED excursim 56 -7 Envelope Ims/gain 3027 1816 48 114 12 a) InBhratim b) Room oemilafiw 791 0 223 0 0 0 0 0 13 Intemal gains: Occupants @ 230 ApplianceVOW 2 460 0 0 1 0 0 Subtotal Qires 6 to 13) 3818 2499 48 114 14 15 Less edema) load Less trarlsfa Redistdbutim _ Subtotal_ _ _. _ Duct bads 249/6 0% 0 0 0 3818 goo 0 0 0 2499 0 24% 0% 0 0 0 48 11 0 0 0 114 0 Total room load Air required (cfm) 4191 99 2112 60 115 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed A �� wrlghisoP[� 2018-Ww2808:55.46 Right -Suite® Universal 2018 18.0.31 RSU08101 Page 6 ...htsoft WACIJAAR ENTERPRISE- 5809 SPRUCE DR..p Celc = MJ8 Front Door faces: E wrightsoft Right- JO Worksheet Job: Date: NOV. 28, 2018 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-4666799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM 1 .2 3 4 5 Room name Erloosed wall Room height Room dimensions Room area M BATH 9.0 ft 8.0 ft heat/cool 120 x 9.0 ft 108.0 W HALL 0 ft 8.0 It heat/cod 3.0 x 7.0 ft 21.0 ft' Ty Construction number U-value (Btuh/ft' F) Or HTM (Btul✓ftj Area (fI or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool Gross WP/S Heat Cool Gnus WP/S Heat Cod 6 11 W/ L-f3 1394acs 2glazing„drlowc_, 13A-4ocs 2 glazing, dr low-e 2 glazing, clr low a 2 glazing, dr Irnva 2 olazing :dr to v e 13A4dcs 2 glazing,.dclwr-e_ 13AA0cs 2 glazing, dr low-e 2 glazing, dr Iowa 2 glazing, dr lov-e ,16A30ad -_ _ 22A-tph -b 143 ___0.580 0.143 0.580 0.580 0.580 -0.580 0.143 -_0.580 0.143 0.580 0.620 _ 0.650 032 n _n_ a a a a e_ -s _s_ w w w w -_ 4D0 -_16.24 4.00 16.24 16.24 16.24 16.24 4.00 -,16.24 4.00 16.24 17.36 18.20 =0.90 38.02 " 219 _13.73 219 31.76 31.76 31.76 31.76 .___ 219 -13.73 219 31.76 30.44 29.93 �224 0.00 --b 0 - 0 w_0 0 0 0 0 0 60 _-12 0 0 0 0 .= _ 108 9 ---0 __0 0 0 0 0 0_ 0 ___0 0 0 0 0 0 131 _ _765 0 0 O - 0 0 0 W W 0 0 0 0 _ _ 0_ J 72 12 0 0 0 0 =f08 108 `0 0 0 0 0 0 -0---0-0 -_0 __ 0 0 0 0 0 -0 0 0 0 0 0 ____0 0 0 0 0 __ 0 -0 -0 240 -_195 ---0 0 0 0 0 �_ 97 342 0 0 0 0 _242 0 0 0 0 0 _21 21 0 0 0 0 _ft 0 0 0 0 0_ , _70 0 0 0 0 0 =47 0 _ __ C_ - F _0 1.358 _ 6 c)AED excursion -34 3 Envelops loss/gain 874 504 19 44 12 a) Infiltration b) Room ventilation 181 0 51 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 01 0 0 0 Subtotal (lines 6 to 13) 1055 555 19 44 14 15 Less edemel load Less transfer RecisMbution Subtotal ___ -Duct loads 24% 0% 0 0 0 1055 250 0 0 0 555 0 24% 0% 0 0 0 0 0 0 0 0 Total loom load Air required (cfm) 1305 53 555 25 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed wrrgF�isof'e' 2018-Wv 28 08:55:46 h Right -Suite® Universal 2018 18.0.31 RSU08101 Page 7 ...hlsoH WAC\JAAR ENTERPRISE- 6809 SPRUCE DR.mp Calc - MJ8 Frenl Door faces: E wrightsoft' Right-J®Worksheet Job: Entire House Date: NOV.28, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-46641796 Email: DUICKCALCS@?AOL.COM 1 2 -3 4 5 Room name Ertasedwall _ Room height Room dimensians Room area FOYER DINING ROOM 15.0 ft. 14o it heat/cool 15.0 x 16.0 it 240.0 ft' Ty Const=ton number U-value (Btuh/WF) Or HTM (Btulvftl AID (M or perimeter (ft) Load (Btuh) Area or perimeter Load Heat Cod Gross N/P/S Heal Cool Gross WP/S Heat Cool 6 11 !.=^. W 2 glaiing_dr,low e_ 13AAocs 2 glazing, dr low-e 2 glazing, dr Iowa 2 glazing, dr lows 2 glazlrg, cl lov_e _ 134-0acs 2glazing,.clrl a— -"-Oh43 _0.580 0.143 0.580 0.580 0.580 ,_,_0,580 0.143 .-0.580 n _n_ a a a a a s _s_ 4:00'239 _16.24 4.00 16.24 16.24 16.24 16.24 �4.00 _16.24 —13.73 2.19 31.76 31.76 31.76 31.78 2.19 .__13.73 `--o o 0 -"-0 0 —.._ 0 _0 210 30 6 7 �,_,20 0 —0 147 0 0 0 0 587 487 101 110 331 0 —__0 __0 321 953 198 216 _648 0 __-0 _ IW �- -G 0 —_0 W I---G b= F 13AAocs 2 glazing, dr taus 2 glazing, dr low-e 2 glazing, dr low-e 16A30ed 22A-tph _- 0.143 0.580 0.620 0.650 =0.032 w w w w 4.00 16.24 17.36 18.20 =0.90 38.02 219 31.76 30.44 29.93 =2.24 0.00 0 0 0 0 =240 ` 240 0 0 0 0 =240 15 0 0 0 0 i215 570 0 0 0 0 i538 0 = —_ — --- 1.358 6 c)AED excursion -154 Ernelope loss/gain 2402 2719 12 a) Irdflration b) Room ventilation 527 0 149 0 13 Imemal gains: Occupants @ 230 Appliances/other 0 0 1500 Subtotal (ling 6 to 13) 2930 4368 14 Less edemal load Less transfer Redshibution Subtotal _ Ductloatls 0% 0 0 3 2933 695 0 0 7 4375 0 - 24% ri Total roanload Air required (am) 3628 147 4375 197 Calculations approved bV ACCA to meet all requirements of Manual J 8th Ed. -rw =!;. otf!- 201&Wv2808:55:46 A '�' Right -Suite® Universal 201818.0.31 RSU08101 Page 8 ...hlsoft HVACUAAR ENTERPRISE- 5809 SPRUCE DR.mp Celc = MJB Front Door faces: E wrightsoft- Duct System Summary Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466.6796 Email: DUICKCALCSCAOL.COM For. JAAR ENTERPRISES, JCAND SONS HOME BUILDERS, INC. 5809 SPRUCE DRIVE, FORT PIERCE, FL 34982 Job: Date: NOV. 28, 2018 By: Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply / return available pressure 0.500 / 0.500 in H2O 0.500 / 0.500 in H2O Lowest friction rate 1.000 in/100R 1.000 in/100ft Actual airflow 1000 Cfm 1000 cfm Total effective length (TEL) 192 ft Supply Branch Detail Table Name Design (Btuh) Htg (elm) Clg (Cfm) Design FIR Diam (in) H x W (in) Duct Mail Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 944 38 17 1.000 4.0 OxO VIFx 37.4 115.0 st2 BEDROOM 2 h 3584 145 96 1.000 7.0 Ox0 VIFx 49.1 135.0 st4 BEDROOM 3 h 3440 139 93 1.000 7.0 OxO VIFx 28.0 115.0 st2 FOYER DINING ROOM C 2188 73 98 1.000 7.0 OxO VIFx 31.7 115.0 st2 FOYER DINING ROOM- C 2188 73 98 1.000 7.0 0x0 VIFx 37.4 150.0 st2 KITCHEN c 2159 6 97 1,000 7.0 Ox0 VIFx 8.2 115.0 St1 LAUNDRY c 1243 35 56 1.000 6.0 Ox0 VIFx 11.2 115.0 St1 LIVING ROOM c 2463 77 111 1.000 7.0 Ox0 VIFx 50.4 135.0 st4 LIVING ROOM -A c 2463 77 111 1.000 7.0 Ox0 VIFx 56.6 135.0 st4 M BATH h 1305 53 25 1.000 5.0 Ox0 VIFx 9.5 115.0 St1 Mw1C c 114 2 5 1.000 4.0 Ox0 VIFx 8.2 115.0 St1 MASTER BEDROOM -A h 4722 191 112 1.000 7.0 Ox 0 VIFx 20.6 135.0 st3 NOOK h 2238 90 82 1.000 6.0 Ox0 VIFx 21.3 135.0 st3 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (Cfm) FIR (fpm) (in) (in) Material Trunk st3 Peak AVF 281 194 1.000 806 8.0 0 x 0 VinlFlx st1 st2 Peak AVF 623 623 1.000 794 12.0 0 x 0 VinlFlx st4 Peak AVF 299 317 1.000 717 9.0 0 x 0 VinlFlx st2 st1 Peak AVF 377 377 1.000 691 10.0 0 x 0 VinlFlx --- ^• Wrightsof - 2018-Nov2808:55:47 ,4CCI1 •� ^•� M-.m^�. Right -Suite® Lhiiuersal 2018 18.0,31 RSU08101 Page 1 ...hie Oft WACWAAR ENTERPRISE- 5809 SPRUCE DR.mp Cell = MJ8 Front Doorfaces: E Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (n) Stud/Joist Opening (in) Duct Matl Trunk fit Ox0 1000 1000 0 0 0 0 Ox 0 VIFx * Wrlght9of - 2018-%2808:55:47 Z Right-Suiteg Universal 2018 18.0.31 RSU08101 Page 2 ...htsoft WAC\JAAR ENTERPRISE- 5609 SPRUCE DR.rup Calc = MJB Front Door faces: E