HomeMy WebLinkAboutSINGLE HUNG WINDOW PAPERWORKI
Ivz•M3NEM9tbMEN
FE
lam' m
AMLM
t
zxr
Cqo wAMIE11,
CAI
M
FOREDBE:3/A'
1 IStAAiE�ID
1/4-MO 3
SHIM SPACE
xmM
zmm
Sew ]mm
6U; DI E
GLAZING DETAIL
FRAME SECTION (T/P)
VERTICAL SECTION
ua• MAx
stall SPACE 3
i7,
•• �
N�0®
MIDI DssrANCE
F(W ED6E:3/P
t 2 UWOODFMME
TYPICAL
fF� �1052 11r
ELEVATION WITH FASTENER SPACING
1
I
11
iw-' EMBEDMENT
Installation Notes:
1. Seal flangelframelto substrate.
2. Use #10 PH or greater fastener though the nail fin with sufficient length to penetrate a minimum of 1
112" into the woodiframing. For 2X wood frame substrate (min. S.G. = 0.42).
3. Host strucare (wood buck, masonry, steel) to be designed and anchored to properly transfer all loads
to the structure. The host structure is the responsibility of the architect or engineer of record for the
project of installation.
Digitally signed by Hermes F. Norero, P.E.
Reason: I am approving this document
Date: 2014,09.19 16:25:32 -"00'
This schedule addresses� Ii
window to achieve the rad i
noted. It is not intended as a
not address he sealing cc nsk
conditions. For the comp late
packaged with the windoyv or
DISCLAIMER:
This drawing and its cm
reproduced or copied in
except as authorized by
the fasteners required to anchor the
lesign pressure up to the size limitations
guide to the installation process and does
oration that may arise in different wall
Installation procedure, see the instructions
are confidential and are not to be
i or in oarl or used or disclosed to others
Inc.
SOB
I1�1/I//I
7
L N
iRn to ase
8 Lu19 I I NAM FIN INSTALLATION
2X w000 I iS
FRAME 3 t C/e r
11/2- MIN
EMBEDMENT
MAX
JAMB SECTION I(TYP)
HORIZONTAL SECTION
wme rwn ar.eae uvuy naB, a was DwAs
PREMIUM ATLANTIC VINYL SH WINDOW
Max Frame 1 DP RATING IMPACT
52 1/8 x 75 1 +50/-60 1 YES
LARGE MISSILE IMPACT
General Notes:
1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria
of the adopted International Building Code(IBC), the International Residential Code(IRC), the Florida
Building Code (FBC) including HVH2 and the industry requirement for the stated conditions.
2. All glazing shall conform to ASTM E1300.
3. Al minimum, glazing is 3mm annealed -11mm airspace - 3mm annealed - 2mm PVB Intedayer by
DuPont - 3mm annealed.
4. Use structural or composite shims where required.
'amEcr Encu3crx: uAir. 3737 Lakeport Blvd
-- 68/13/2014
Klamath Falls, OR. 97601
D. Vezo NTS Phone: (541) 882-3451
Premium Atlantic Vinyl Impact Single Hung Window
00Iw—1OF3