A. Wood:
1. All lumber on or below grade shall be ACQ Pressure Treated Southern Yellow Pine 02 Grade (Fb = 1,000 pei min,)
2. All lumber above grade (non -decking) shall be Southern Yellow Pine 02 Grade
3. All framing lumber shall be hem -fir 02 grade or equivalent
4, Wood structural panels Shall be W' Mtn, thickness, exposure I structural Sheathing
5. In all Instances where aluminum comes into contact with pressure treated wood, provide dielectric separation
B. Concrete (See Site Preparation for Existing Concrete)
C. Masonry: N/A
D, Aluminum
1. All structural aluminum conforms to the minimum requirements of 6005 - T5 for alloy and temper:
2, All structural aluminum work conforms to "Part I -A - specifications for aluminum structures - allowable stress design:
or "Part 1-5 - Specifications for aluminum structures - building load and resistance factor design" of The Aluminum
Association, Inc. Seventh Edition, Effective January 2000
3, In all instances where aluminum comes into contact with steel, or pressure treated lumber provide dielectric separation
E. Solid Wall Panels
1. Aluminum panel skin Is Alloy 3105 - H14/1-125 and IS 0.024" thick min,
2. Panel Core Foam Is Preformed Expanded Polysterene Board (EPS).
F. Sealant .. I. All sealant conforms to TT - 8 - 001543 - A, TT - S - 002306, ASTM C - 920 Type S, Grade NS, Class 25.
Sealant to be used for structural adhesion 4 to prevent water intrusion.
G. Gaskets .. 1. All gaskets are co -extruded and are non -migratory.
H. Fasteners
1. All lag bolts shall conform to stainless steel type 300 IS - 8, with standard flat washer unless manufacturer galvanized
bolts specifies for use with ACQ pressure treated wood
2. Hex bolts has be ASTM A325, plated with standard flat washers and nuts
3. All concrete Serowe Shall be 4" x 2 ly" min., Simpson, Hiltl, Rawl, Tapoon, Redhead, Dynabolt, or approved equal
4. All metal ties and associated accessories shall be hot dipped galvanized
5, All lag bolts shall have a minimum embedment of 8x bolt diameter into structural framing (G a .42 min.)
6. Lag bolts and screw* into wood framing shall be provided with pilot holes having a diameter
not greater than 10 percent of the thread diameter of the bolt or screw. All lag bolts and
screws shall be inserted in pilot holes by turning and under no circumstances by driving with a hammer.
1. All expansion anchors shall be designed in accordance with the Specific manufacturers requirements
and allowable loads and shall only be applied in conditions acceptable to manufacturer
8, All fasteners connecting aluminum components or pressure treated lumber are stainless steel
type 300 18 - 8 unless manufacturer galvanized bolts specifies for use with ACQ pressure
treated wood, or otherwise noted on plans
S. All fasteners shall comply with ASTM A153
10. All connectors Shall comply with ASTM A653 Class G - 18
I. Site Preparation
1. Foundation *ystems must be placed on clean, compacted,
termtte-treated fill/soil with vapor barrier.
2. Existing Foundation, footing and slab if noted on the Floor Plan have been
evaluated 4 found acceptable for this application.
J. Reference Standards:
ASTM E 119... ASTM E 1300... ASCE 1-10... AAMA/NPEA 2100-02
B.O. Use and occupancy category 2
4.0: All fenestration products comply
5.0: All wall and roof panels and aeeembiles comply
6.0: Does not apply to category 2
1.0: All applicable provisions comply
K. N/A
L. DESIGN LOADS:
This structure has been designed In accordance with, 4 meets the requirements of
the Florida Building Code, Residential 2011 6th Edition 4 Amendments 4 ASCE 1-10
per Section R301.2.1,1, 4 all applicable sections of R301 design criteria.
Design Criteria:
Design Roof Load: Dead Load (Addition): 10 PSF Live Load (Roof): 20 PSF
Wind velocity (ULT): I60MPH (3 sec gust) Exposure: B Risk Category: i
Building Height: < 30' Mean Roof Height: <15'
Enclosure type: Screen Area - Open
Max Components and Cladding Pressures:
Roof Zone is +12.2/-32.3 per... Roof Zone 2 4 3: +12,2/-38.2 per
M. Abbreviations
The following list of abbreviations is not Intended to represent all those
used on these drawings, but to supplement the more common abbreviations
used: TYP. - Typtcal SIM. - Similar UNO. - Unless Noted Otherwise
CONT. - Continuous V.I.F - Vertfy In Field
N. Responsibility
1. All site work shall be performed by a licensed contractor in accordance
With applicable building codes, local ordinances, etc.
2. Contractor shall verify all dimensions and details, notifying engineer of any
dlecrepancies between drawings, fabricated items, or actual field conditions
3. These drawings represent the acceptablllty of the "Screen -room" room addition
elements as provided by the contractor
4. All details on these drawings are engineered based on information
provided by the contractor
5. Refer to the manufacturers shop drawing for further details
6. Any details not shown are to be engineered in
accordance with Standard engineering Practices,
ALUMINUM INTERNAL U-CLIP - 0.125"
w/ (1) 3/8" WEDGE ANCHOR - MIN 3" EMBED
CONNECT TO COL. w/ SAME (4) *12 x I" SELF -TAP
SCREWS EA SIDE t0 EXTERNAL CLIPS ,I II,,,,I,III,,,, �, l I,. _.
P "Wl III11YI 1 VVV. J
SEE PLAN FOR LOCATIONS
-Y x 3" x 3" x 0.125" ALUMINUM EXTERNAL L-CLIP--\, MIN.
w/ (1) 3/8" WEDGE ANCHOR - MIN 3" EMBED SETBACK
w/ (4) *12 x 1" SELF -TAP SCREWS TO CLiP O a FOR SCREW
(1) CLIP EA SIDE OF COL. o 311
EXISTING CONC. BLAB 1� �f
_ ... _ TYP. OPEN CARPORT / 4TH WALL COL, TO CONIC, DETAIL
NOT TO SCALE
° ° $ x 3 x 0.125 ALUMINUM BEAM °
0 o AT EACH GABLE END
CONNECT BEAM TO POST
w/ 3" x 3" x 3 1/8" x .25" "C" CHANNEL CLIP
w/ (8) *12 x 3/4" SMS EA END
( 4 EA SIDE OF BEAM )
CONNECT CLIPS TO 3 x 3 x 0.125 POST
w/ (2) 1/2" THRU-BOLTS w/ WASHERS
POST / SAME THRU BOLTS USED FOR SMB CONNECTION ENDPOS/
COI_COL
END BEAM CONNECTION TO POST/COL
NOT TO SCALE
REPAIR COVERED
'.ARPORT / SHED / SCREENROOM ADDITIOr
CONNECTED w/
FLASHING ONLY EXISTING ROOF
TYP.
EXISTING
PAN ROOF
SCALE: i/4" = 1'-O"
EXISTING ROOF
CONNECTED w/
FLASHING ONLY
1015ILE HOME
RESIDENCE
4TH WALL
COVERED CARPORT
FRONT ELEVATION
SCALE: 1/4" = 1'-0"
CONNECT KNEE BRACE TO
POST / BEAM w/ .125" "C" CHANNEL
SCREWED TO POST / BEAM
w/ MIN. (4) 012 x 314" SMS 4 TO BRACE
w/ (8) 012 x 3/4" SMS EA END
( (4) EA SIDE OF KNEE BRACE )
ALUMINUM BEAM
TYP.
EXISTING
PAN ROOF
°CCC I
24" EACH WAY
ALUMINUM
POST
MIN 3" x 3" .125"ALUM
FOR KNEE BRACE
PERT KNEE BRACE
NOT TO SCALE
FRONT ELEVATION COVERED CARPORT EXSITING SHED SCREENROOM
SCALE: 1/4" = I'-O" TO REMAIN
EXISTING MOBILE RESIDENCE 4 OPENINGS TO R
--_--r �_�- - �-A _'r _ - - -- _ - A
ocier
A -_
R
I Im G6.
EXSITING
COVERED
REW7z,nVr,m /CARS''
CODE COt',qi; >t 4 E + I v
_ L UCJ TYPICAL ALUMINUM COL. SYMBOL KEY
�tia�'a i 1 QA 3 x 3 x .125 HOLLOW ALUMINUM
/-
12'-0"
FILE COPY 601-0"
FLOOR PLAN
SCALE: 1/4" = 1'-0"
r 4TH WALL
EXSITING SHED
12'
---------------
4TH WALL - 2 x 4 SMB
I
EXSiTING -
SCREENROOM I Q
EXISTING CONCRETE
SLAB 4 FTG,
TO REMAIN I
2x4SMB
a
12'-O"
C3t=Nl=XAL f XUJtC. I NV I t5
I: CONSTRUCTION TO FOLLOW THE REQUIREMENTS OF THE FLORIDA
BUILDING CODE 2011 6T44 EDITION a WIND CRITERIA PER ASCE 1-10.
2: ELEVATIONS ARE REPRESENTATIVE ONLY
THIS SCREEN STRUCTURE HAS BEEN DESIGNED
IN ACCORDANCE WITH THE FLORIDA
BUILDING CODE 2011 6TH EDITION WITH ALL
SUPPLEMENTS AND ASCE 1 - 10 ENG. BOOK
160 ULT MPH (3-SEC. GUST) WIND VELOCITY.
EXP "B OPEN ENCLOSURE
SLAB/FOUNDATION NOTES -�
EXISTING SLAB a FOUNDATION TO REMAIN
FLASH 4 CAULK EXISTING
HOME ROOF TO NEW ROOF
(3) *14A S.M.S. SCREWS
w/ I I/2" S.S. NEOPRENE GASKET WASHER
SCREWS a MAX 2" FROM EA SIDE 4 CENTER
PER PAN ROOF -PANEL EXISTING HOME
e FRONT 4 4TH WALL REAR EDGE ROOF OVERHANG
w/ MIN. I" EMBED INTO BEAM
PAN -ROOF
PANEL
FRONT EDGE 4 REAR
NOTCH ALUMINUM COLS.
FOR EXTRUDED 2 x 4
SELF MATING ALUMINUM BEAM I�
ATTACH w/ MIN (1) 1/2"
THRU BOLTS 4 WASHERS +I I
( USE (2) BOLTS AT END COLS.) L JJ
EXTR'D ALUM 3" x 3" x 0.125" COL.
TYP ROOF / BEAM / COL. / CONNECTII
NOT TO SCALE
:)N SECTION
ALUMINUM COL.
SEE PLAN FOR SIZING
(2) 3" x 2" x 3" x .125 ALUMINUM CLIPS (U EA. SIDE
MIN. r w/ (2) 3/9" CONCRETE SCREWS - MIN 2" EMBED 4
s>=rBacK o w/ (4) 012 x I" SELF -TAP SCREWS PER CLIP
SCREW
+/- 2"
(SEE FOUNDATION / SLAB NOTES /PLAN)
C7
TYPICAL SCREEN ROOM COL. TO CONCRETE DETAIL
NOT TO SCALE
SCOPE:
THE PURPOSE OF THIS SKETCH IS TO DEFINE A REPAIR TO BRING
AN EXISTING ALUMINUM CARPORT UP TO CODE BY ADDING A '4TH WALL'
AND REMOVING AND REPLACING ALUMINUM POSTS AND BEAMS,
FOR THE REPAIR STEPS, USE THE FOLLOWING:
1. R<R EXISTING POSTS AND OUTER CARRIER BEAM USING NEW 3X3X,125
POSTS AND 2X4 SMB AS SHOWN.
2. RECONNECT ROOF PANS TO NEW CARRIER BEAM AS SHOWN.
3, ADD '4TH WALL' POSTS/BEAM ADJACENT TO EXISTING HOME USING
3X3X.125 POSTS AND 2X4 SMB AS SHOWN.
4. CONNECT ROOF PANS TO NEW BEAM AS SHOWN
S. REMOVE ROOF PAN CONNECTION TO MANUF HOME SO ROOF PANS
ARE NO LONGER ATTACHED TO MANUF HOME EXCEPT FOR FLASHING.
6, THE ALUMINUM SHED WAS INSPECTED AND IS ACCEPTABLE AS IS,
O
rr
WM
O
O Cn IT
M
Z a A N
W _ 00
B o0
ZOCR
a�
v
v�w3
a'
iL
O
U
tu
m
LU
LL
Q
lu
d)
LU
U'
r`
>41-�
LU
1-2
SCANNED
St.
BY
Lucie County
® Copyright 2019
All rights reserved.
REVISION DATE
q63 - 7
JOB M SW ISOI
DATE : 1/21/IS
SHEET