HomeMy WebLinkAboutNOARECEIVED
MIAMPDADE
a
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
MAR 01 Zt11B
P2rmltting Department
MIAMI-DADE COUNTY
PRODUCT SECTION
St. Woe Leunty
CONTROL
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Gardner Asphalt Corporation
4161 W. 7" Avenue FILE COPY SCANNED
Tampa, FL. 33605 BY
St. Lucie County
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Gardner Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building OfftcMLr
SE PLANS AND ALL PROPOSED i/VORK
ARE SUBJECT TO ANY CORRECTIONS
This NOA revises NOA 4 18-0409.06 and consists of pages 1 through 6. REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
The submitted documentation was reviewed by Freddy Semino COMPLY WITH ALL APPLICABLE CODES.
T
NOA: 18-1109.03
� gijpa,lio, Date: 03/28/23
ST. LUCIE COUNTY�BU NG D ION1-Date: 01/03/19
REVIEWED FOR SQMPLIANCF��a Page I of 6
ru NZ Hivu rtnrrt I MUST BE KEPT
SITE OR NO INSPECTION(S) WILL E
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: Asphalt
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specification Description
APOC Tuff -Felt 26 36" x 72' rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment, 2
Manufacturing square #30.
Location 41, 2
United FGUR20 36" x 72' rolls
Manufacturing
Location 41, 2
APOC 25 36" x 72' rolls
Manufacturing
Location #1, 2
N6.30 ASTM 36" x 72' rolls
Manufacturing
Location #1. 2
APOC Tuff -Felt 46 36" x 144' rolls
Manufacturing
Location #l, 2
United FGUR10 36" x 144' rolls
Manufacturing
Location #1, 2
APOC45 36" x 144' rolls
Manufacturing
Location #l, 2
No. 15 ASTM 36" x 144' rolls
Manufacturing
Location #1, 2
United FGUR70 18" x 72' rolls
Manufacturing
Location #11 2
ASTM D 226 Type II Asphalt Saturated Felt underlayment, 2
square 430.
ASTM D 226 Type II Asphalt Saturated Felt underlayment, 2
square #30.
ASTM D 226 Type II Asphalt Saturated Felt underlayment, 2
square #30.
ASTM D 226 Type I Asphalt Saturated Felt underlayment, 4
square #15.
ASTM D 226 Type I Asphalt Saturated Felt underlayment, 4
square #15.
ASTM D 226 Type I Asphalt Saturated Felt underlayment, 4
square #15.
ASTM D 226 Type I Asphalt Saturated Felt underlayment, 4
square #15.
ASTM D 226 Type II Asphalt Saturated Felt underlayment, 1
square #30.
NOA: 18-1109.03
Expiration Date: 03/28/23
Approval Date: 01/03/19
Page 2 of 6
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specification Description
GatorSkin 42" x 285.8' rolls ASTM D 226 Type II Synthetic roof underlayment comprised
Manufacturing of layers of polyolefin film.
Location #3
GatorSkin-10
42" x 285.8' rolls ASTM D 226 Type II
Synthetic roof underlayment comprised
Manufacturing
of layers of polyolefin film.
Location #5
Weather -Armor CX-L
37.25" x 145' rolls ASTM D 226 Type II
High strength hybrid underlayment
Manufacturing
comprised of two layers of polyolefin and
Location #3
polyester synthetic fabric with a thin layer
of modified bitumen between the two
plies.
Weather -Armor SB-1
36" x 65' 8" rolls ASTM D 1970
Glass fiber reinforced, polymer modified
Manufacturing
asphalt, granulated self -adhered
Location #4
underlayment.
Gard -Lock
36" x 65' 8" rolls ASTM D 1970
Glass fiber reinforced, polymer modified
Manufacturing
asphalt, granulated self -adhered
Location #4
underlayment.
Weather -Armor HT'
39" x 65' 8" rolls ASTM D 1970
60-mils. thick (nominally), self -adhering
Manufacturing
membrane composed of elastic polymers,
Location #4
bitumen, glass reinforcements and a cross
laminated sheet surfacing.
Weather -Armor FT'
39" x 65' 8" rolls TAS 103
60-mils. thick (nominally), self -adhering
Manufacturing
membrane composed of elastic polymers,
Location #4
bitumen polyester and glass
reinforcement.
Eagle -Armor by Apoc
39" x 65' 8" rolls TAS 103
60-mils. thick (nominally), self -adhering
Manufacturing
membrane composed of elastic polymers,
Location #4
bitumen polyester and glass
reinforcement.
MANUFACTURING LOCATIONS:
1. Tacoma, WA.
2. Eutaw, AL.
3. Hangzhou, China.
4. Springville, AL.
5. Tampa, FL.
NOA: 18-1109.03
Expiration Date: 03/28/23
Approval Date: 01/03/19
Page 3 of 6
EVIDENCE SUBMITTED:
Test Aeencv
Test Identifier
Test Name/Report
Date
PRI Construction Materials
GGI-100-02-01
ASTM D 226
06/22/12
Technologies
GGI-101-02-01
ASTM D 226
06/22/12
GGI-132-02-01
ASTM D 226
04/28/15
GGI-176-02-01
ASTM D 226
09/26/16
GGI-178-02-01
ASTM D 1970
10/25/16
GGI-194-02-01
ASTM D 1970
08/04/17
GGI-196-02-01
TAS 103
08/08/17
GGI-206-02-01
ASTM D 226
03/09/18
GGI-207-02-01
ASTM D 226
03/09/18
GGI-201-02-01
ASTM D 1623
01/29/18
GGI-178-02-01
ASTM D 1970
01/29/18
GGI-178-02-02
ASTM D 1970
01/29/18
GGI-199-02-02
ASTM D 226
12/12/17
GGI-202-02-01
ASTM D 1623
08/09/18
APPROVED ASSEMBLIES:
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened to deck.
Anchor Sheet: One or more plies of APOC Tuff -Felt 26, United FGUR20, United FGUR70, APOC 25, No. 30
ASTM, GatorSkin, GatorSkin-10 or Weather -Armor CX-L with a minimum 4" headlap and a 6"
end lap mechanically fastened to deck with approved nails and tin caps 6 inches o.c. minimum
at all laps and three staggered rows fastened at 12 inches o.c. minimum in the field of the roll.
Nails shall be driven flush and 90 degrees to the roof deck.
Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry
slate, metal roof applications, and as an anchor sheet in roof tile applications. Must Comply with
applicable Roofing Application Standards and Building Codes.
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(2): Anchor sheet mechanically fastened to deck.
Anchor Sheet: Minimum 2 plies or more of APOC Tuff -Felt 46, United'FGUR10, APOC 45, or No. 15 ASTM
with a minimum 19" headlap and a 6" end lap mechanically fastened to deck with approved
nails and tin caps 6 inches o.c. minimum at all laps and three staggered rows fastened at 12
inches o.c. minimum in the field of the roll. Nails shall be driven flush and 90 degrees to the
roof deck.
Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry
slate, metal roof applications, and as an anchor sheet in roof tile applications. Must Comply with
applicable Roofing Application Standards and Building Codes.
NOA: 18-1109.03
Expiration Date: 03/28/23
Approval Date: O1/03/19
Page 4 of 6
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(3): Anchor sheet mechanically fastened to deck, membrane adhered.
Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" headlap and.a
6" end lap mechanically fastened to deck with approved nails and tin caps 6"o.c. at the side lap
edge and in a grid pattern spaced 12"o.c. in the field of the roll.
Membrane: One or more plies of Weather -Armor SB-1, Gard -Lock, or Weather -Armor HT' self -adhering
membrane adhered to the anchor sheet with a minimum 3" headlap and 6" end lap.
Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry
slate, and metal roof applications. Must Comply with applicable Roofing Application Standards
and Building Codes.
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(4): Anchor sheet mechanically fastened to deck, membrane adhered.
Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" headlap and a
6" end lap mechanically fastened to deck with approved nails and tin caps 6"o.c. at the side lap
edge and in a grid pattern spaced 12"o.c. in the field of the roll.
Membrane: One or more plies of Weather -Armor FT' or Eagle -Armor by Apoc self -adhering membrane
adhered to the anchor sheet with a minimum 3" headlap and 6" end lap. or
Surfacing: 0 Weather -Armor FT' and Eagle -Armor by Apoc Shall be acceptable for use in approved
asphaltic shingles, wood shakes, & shingles, quarry slate, metal roof, and mechanically
fastened roof tile applications.
• Weather -Armor FT' and Eagle -Armor by Apoc may be used with any approved adhered
roof tile system as specified in their current NOA using the following tile adhesives with
current NOA:
• The Dow Chemical Company's TILE BOND Roof Tile Adhesive
• ICP Adhesives and Sealants, Inc.'s ICP Adhesive Polyset AH-160
-DAP Touch `n Seal Storm Bond Roof Tile Adhesive
Must Comply with applicable Roofing Application Standards and Building Codes.
LABELING:
All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city,
state and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County
Product Control Seal as shown below.
NOA: 18-1109.03
MAMMADE COUNTY ,...0 Expiration Date: 03/28/23
.
Approval Date: 01/03/19
Page 5 of 6
• . -
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate
the installation of this material.
LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance
with applicable building code.
3. Weather -Armor SB-1, and Weather -Armor HT shall not be hot mopped; refer to manufacturer's published
literature for product compatibility.
4. Gardner Underlayments listed herein are components used in roof assemblies. Roof assemblies are approved
under specific assembly Notice of Acceptance.
5. APOC-Tuff Felt 26, United FGUR20, APOC 25,No. 30 ASTM, APOC-Tuff Felt 46, United FGUR10,
APOC 45, No. 15 ASTM, United FGUR70, GatorSkin, GatorSkin-10 and Weather Armor CX-L listed
herein shall not be left exposed as a temporary roof for longer than 30 days of application.
6. Gard -Lock and Weather Armor SB-1 listed herein shall not be left exposed as a temporary roof for longer
than 90 days of application.
7. Weather -Armor HT', Eagle -Armor by Apoc and Weather -Armor FT3 listed herein shall not be left exposed
as a temporary roof for longer than 180 days of application.
8. Gardner Underlayments listed herein may be used with any approved roof covering Notice of Acceptance
listing Gardner Underlayments listed herein as a component part of an assembly in the Notice of Acceptance.
If Gardner Underlayments listed herein is not listed; a request may be made to the Authority Having
Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that
appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire
testing results.
9. For fire classification of specific roof assemblies using Gardner Underlayments listed herein refer to a
current Approved Roofing Materials Directory for fire ratings of this product.
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA: 18-1109.03
Expiration Date: 03/28/23
Approval Date: 01/03/19
Page 6 of 6
tq(3 3--
RECEIVED
MAR 01 1018
MIAMh ,. .a Permitting pgpartmant
t St. Luale' eunty
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPT,
Gardner Asphalt Corporation
4161 E. 7 Avenue
Tampa, FL 33605
�g103-0oZJ
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.gov/economy
SCANNED
BY
St. Lucie County
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: APOC/Gardner Asphalt Cements, Adhesives and Coatings
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA# 17-1031.04 and consists of pages 1 through 13.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 18-0411.03
Expiration Date: 02/01/21
Approval Date: 01/03/19
Page I of 13
ROOFING COMPONENT APPROVAL
Category
Sub -Category
Material:
Maximum Design Pressure
Roofing
Cement -Adhesive -Coatings
Asphalt
N/A
APPROVED DISTRIBUTORS:
Gardner Asphalt Corporation products are also distributed by RSI, Tri-Built Materials Group and Roof Doctor Inc.
MANUFACTURING LOCATION:
1. Tampa, FL.
EVIDENCE SUMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
Underwriter Laboratories, Inc.
R13663
Fire Classification
2008
PRI Asphalt Technologies
GGI-152-02-01
TAS 138
01/08/16
GGI-116-02-01
ASTM D 6083
04/08/13
GGI-131-02-01
ASTM D 6694
10/08/15
GGI-145-02-01
ASTM D 4586
12/15/15
GGI-143-02-01
ASTM D 4586
12/15/15
GGI-146-02-01
ASTM D 4586
12/15/15
GGI-148-02-02
ASTM D 41
05/27/16
GGI-147-02-01
ASTM D 4586
12/15/15
GGI-149-02-01
ASTM D 2824
12/15/15
GGI-159-02-01
ASTM D 3019
05/24/16
GGI-160-02-01
ASTM D 4586
05/24/16
GGI-157-02-01
ASTM D 3019
05/24/16
GGI-158-02-01
ASTM D 4479
05/24/16
GGI-162-02-01
ASTM D 2824
05/25/16
GGI-162-02-01
ASTM D 2824
05/25/16
GGI-161-02-01
ASTM D 1227
05/24/16
GGI-156-02-01
ASTM D 1227
05/24/16
GGI-165-02-01
TAS 139
05/24/16
GGI-166-02-01
ASTM D 6083
05/24/16
GGI-164-02-01
ASTM D 3409
05/24/16
GGI-200-02-01
ASTM D 2824
10/05/17
GGI-213-02-01
ASTM D 903
08/03/18
SNC-023-02-01
ASTM D 903
08/03/18
Momentum Technologies, Inc.
DX17L4A
03/15/05
NOA No.: 18-0411.03
MIAWDADE COUNTY Expiration Date: 02/01/21
1 Approval Date: 01/03/19
Page 2 of 13
PHYSICAL PROPERTIES OF COMPONENTS:
Trade names:
Gardner Fibered Emulsion Roof Coating #GA 040
APOC #302 Fibered Emulsion Roof Coating #AP 302
APOC #337 Fibered Elastomeric Asphalt Emulsion #AP337
WeatherSeal Fibered_Emulsion Roof Coating #WS 240
Black Jack Rubr-Coat #57
Gardner Flexx-Gard Ruberized Roof Cement
APOC #339
RX #300
Thickness:
See Description Below.
Specification:
ASTM D 1227 Type IV
Description:
An asphalt base clay -type emulsion coating containing mineral fibers. Non-flammable and
specifically formulated to bond to damp or dry surfaces. For use as a protective surface coating
over built-up ply sheets, mineral surfaced cap sheets, approved single ply membranes and other
asphalt roof surfaces. Apply one or more coats as required at approximately 1 to 3 gal/100 sq.
ft.. Apply second coat at right angle to first coat.
Container Size:
1, 5, 55 gallons. Note all precautions on container.
Systems Approvals:
Methods of application and quantities shall comply with the specific Roof Assembly, Product
Control Notice of Acceptance.
Trade names:
MBA Modified Bitumen Adhesive
APOC #136 MBA Modified Bitumen Adhesive #AP 136
PC 607
APOC#525 ArmorFlex # AP525
RX #200
Tri Built Mod Bit Adhesive
HP225
Thickness: See Description Below.
Specification: ASTM D 3019, Type III
Description: An asbestos free, polymer modified, asphalt based, cold applied adhesive. Apply at an
approximate rate specified below:
•Asphalt BUR: Apply at a minimum rate of 1.5 gal./100 ft'to 4 gal / 100ftz
•Smooth SBS Mod Bit: Apply at a minimum rate of 1.5 gal./100 ftt' to 4 gal / 100fl2
Container Size: 1, 5, 55 gallons. Note all precautions on container.
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly, Product
Control Notice of Acceptance.
NOA No.: 18-0411.03
Expiration Date: 02/01/21
Approval Date: 01/03/19
Page 3 of 13
Trade names:
Gardner Fibered Roof Coating # GA 010, GA610
APOC #202 Fibered Roof Coating #AP 202
WeatherSeal Fibered Roof Coating #WS 210
Thickness:
See Description Below.
Specification:
ASTM D 4479 type I
Description:
A heavy duty fibrated coating of brush consistency. For use on metal, composition and built-uI
roofs. Apply with a brush to form a thin and continuous film. Apply at an approximate rate of
to 3 gal/100 sq. ft.
Container Size:
1, 5, 55 gallons. Note all precautions on container.
Systems Approvals:
Methods of application and quantities shall comply with the specific Roof Assembly, Product
Control Notice of Acceptance.
Trade names:
Gardner Cold Process Roof Cement # GA 036, GA 636
APOC #107 Fibrex Cold Process Adhesive #AP 107
APOC #167 Cold Process Adhesive #AP 107
APOC 4108 Cold Process & Lap Adhesive #AP 108
WeatherSeal Cold Process Roof Cement #GA 236
Thickness:
See Description Below.
Specification:
ASTM D 3019 Type III
Description:
A fibered, asphaltic, quick drying, cold applied adhesive. For use in new construction and
reroofing to bond plies of build-up roofing materials. Also bonds gravel or granules to BUR
roof systems and modified cap sheets. Apply with a brush, notched squeegee, or trowel to form
thin and continuous film. Apply at an approximate rate of 1 1/2 to 5 gal/100 sq.ft. depending
upon surface texture and job requirements.
Container Size:
1, 5, 55 gallons. Note all precautions on container.
Systems Approvals:
Methods of application and quantities shall comply with the specific Roof Assembly, Product
Control Notice of Acceptance.
NOA No.: 18-0411.03
Expiration Date: 02/01/21
Approval Date: 01/03/19
Page 4 of 13
Trade names:
Gardner Wet Surface Roof Cement #GA 037, GA 637
APOC #109 Wet Surface Plastic Roof Cement #AP 109
APOC #124 Wet Surface Roof Cement #AP124
WeatherSeal Wet Surface Roof Cement #WS 237
PC 105
Tri Built Wet/Dry Plastic Cement
Collis Wet/Dry Flashing Cement
RoofCheck Wet/Dry Flashing Cement
TopShield Wet/Dry Plastic Roof Cement
Thickness:
See Description Below.
Specification:
ASTM D 4586 Type I and ASTM D 3409
Description:
An all weather asphalt plastic cement specially designed to bond to water covered or damp
surfaces, as well as dry surfaces. For use to patch splits and cracks less than 1/4" wide in build-
up, mineral surfaced cap sheet and smooth surface asphalt roofs. Also used for repair flashings
around chimneys, stand pipes and other roof projects. Applied with trowel or putty knife,
working material to an even consistency over and into the area to be repaired, approximately
1/8" to 1/4" thick, two or three inches beyond the problem area. Coverage is approximately 12
1/2" sq. ft. when applied 1/8" thick.
Container Size:
1, 5, 55 gallons. Note all precautions on container.
Systems Approvals:
Methods of application and quantities shall comply with the specific Roof Assembly, Product
Control Notice of Acceptance.
Trade names: Gardner Aluminum Fibered Roof Coating Professional Grade #GA 722 and GA 621
APOC #108 Fibered Aluminum Roof Coating #AP 208
WeatherSeal Fibered Aluminum Roof Coating #WS 221, WS 222
PC #401 Fibered Aluminum Roof Coating
Tri Built Fiber Aluminum Coating
TopShield Fibered Aluminum
Thickness: See Description Below.
Specification: ASTM D 2824 Type III
Description: A fibered aluminum roof coating used to protect underlying roofing materials and to reflect the
sun's rays. Applied by spray or brush at an approximate rate of I gal/50 to 100 sq. ft.
Container Size: 1, 5, 55 gallons. Note all precautions on container.
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly, Product
Control Notice of Acceptance.
NOA No.: 18-0411.03
Expiration Date: 02/01/21
Approval Date: 01/03/19
Page 5 of 13
Trade names:
Gardner Aluminum Fibered Roof Coating #GA 723
APOC 9212 Fibered Aluminum Roof Coating #AP 212
APOC #214 Fibered Aluminum Roof Coating #AP 214
RX #450
Thickness:
See Description Below.
Specification:
ASTM D 2824 Type III and ASTM D 3805
Description:
A reflective, aluminum roof coating with fibers which strengthen the protective film.
Recommended for emulsion surfaced or mineral surfaced roofs. Apply evenly by spray or soft
brush and avoid scraping into soft roof surfaces. Apply at an approximate rate of 1 gal/50 to 101
sq. ft..
Container Size:
1, 5, 50 gallons. Note all precautions on container.
Systems Approvals:
Methods of application and quantities shall comply with the specific Roof Assembly, Product
Control Notice of Acceptance.
Trade names:
Gardner Non-Fibered Emulsion Roof and Foundation Coating #GA 042
APOC #300 Non-Fibered Emulsion #AP 300
WeatherSeal Non-Fibered Emulsion Roof & Foundation Coating #WS 242
Thickness:
See Description Below.
Specification:
ASTM D 1227 Type III
Description:
An asphalt based emulsion coating for resurfacing and coating flat deck roofing. Specially
formulated for bonding to damp or dry surfaces. For use over built-up ply sheets, mineral
surfaced cap sheets and other asphalt roof surfaces. Also for use as below grade damproofing.
Apply with a brush or suitable spray equipment in one or more coats as required. Apply at an
approximate rate of 1 gal/50 sq.ft
Container Size:
1, 5, 55 gallons. Note all precautions on container.
Systems Approvals:
Methods of application and quantities shall comply with the specific Roof Assembly, Product
Control Notice of Acceptance.
NOA No.: 18-0411.03
MIAMI-DAD, COUNTY Expiration Date: 02/01/21
ra Approval Date: 01/03/19
Page 6 of 13
Trade names: Gardner Non-Fibered Aluminum Roof Paint #GA 726
APOC #211 Aluminum Roof Paint #AP 211
APOC #207 Aluminum Roof Paint #AP 207
PC #400 Non-fibered Aluminum Roof Coating
RX #460
Tri Built Non-Fibered Aluminum Coating
TopShield Non-Fibered Aluminum
Thickness: See Description Below.
Specification: ASTM D 2824 Type I
Description: A highly reflective, non-fibered aluminum roof paint. Specially designed to repel the sun's
heat on smooth surfaced, emulsion surfaced or mineral surfaced roofs and sheet metal
buildings and roofs. Apply by spray, roller or soft brush, spreading in both horizontal and
vertical directions. Application rate varies depending upon surface. See manufacturer's
specifications.
Container Size: 1, 5, 50 gallons. Note all precautions on container.
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly, Product
Control Notice of Acceptance.
Trade names:
Gardner Professional Asphalt Primer #GA 014, GA 714
APOC #103 Asphalt Primer #AP 103
WeatherSeal Asphalt Primer #WS 214
PC #200 Asphalt Primer
Tri Built Quick Dry Asphalt Primer
TopShield Asphalt Primer
Thickness:
See Description Below.
Specification:
ASTM D 41
Description:
Asphalt primer used to seal newly laid concrete or cement decks prior to applying build-up
roofing. Also for use with below grade damproofing and waterproofing and as a primer on
existing roofs 'prior to recoating or restoration.Apply with brush or spray, working the
material to a smooth and even consistency. Apply at an approximate rate of 1 gal/150 to 200
sq. ft.
Note: Do not thin. Do not apply to wet or damp surfaces.
Container Size:
1, 5, 55 gallons. Note all precautions on container.
Systems Approvals:
Methods of application and quantities shall comply with the specific Roof Assembly, Product
Control Notice of Acceptance.
NOA No.: 18-0411.03
Expiration Date: 02/01/21
Approval Date: 01/03/19
Page 7 of 13
Trade names:
Gardner Plastic Roof Cement #GA 634, GA 034, GA 734
APOC #100 Plastic Roof Cement #AP 100
APOC #104 Rain Proof Plastic Roof Cement #AP 104
APOC #101 Plastic Roof Cement #AP 101
WeatherScahPlastic Roof Cement #WS 234
PC #103
TopShield Roof Cement
Thickness:
See Description Below.
Specification:
ASTM D 4586 Type I
Description:
All purpose, black plastic cement for all types of roof repairs and foundation applications.
Apply with trowel or putty knife, working material to an even consistency over and into the
area to be repaired, approximately 1/8" to 1/4" thick, two or three inches beyond the problem
area. Note: Do not thin. Do not use on wet or damp surfaces.
Container Size:
10%, 30 oz. tube, 1, 5, 55 gallons. Note all precautions on container.
Systems Approvals:
Methods of application and quantities shall comply with the specific Roof Assembly, Product
Control Notice of Acceptance.
Trade names:
Gardner Asbestos Free Flashing Cement #GA 633, GA 033, GA 132
APOC #122 Flashing Cement #AP 122
APOC #128 Flashing Cement #AP128
PC #104 Flashing Cement
Tri Built Flashing Cement
Advanced Roofing Cement
PSG Flashing Cement
TopShield Wet/Dry Flashing Cement
Thickness:
See Description Below.
Specification:
ASTM D 4586 Type I and ASTM D 3409
Description:
Asbestos free, asphalt based trowelable flashing cement for roof and foundation applications..
Apply with a putty knife or trowel, filling all fissures, joints and gaps. Apply at an
approximate rate of 1/8" thick; I gal/12 1/2 sq. ft.. When used on a bonded or warranted roof
system, follow instructions of that application system.
Container Size:
10'/z, 30 oz. tube, or 1, 3, 5 gallons. Note all precautions on container.
Systems Approvals:
Methods of application and quantities shall comply with the specific Roof Assembly, Product
Control Notice of Acceptance.
NOA No.: 18-0411.03
Expiration Date: 02/01/21
Approval Date: 01/03/19
Page 8 of 13
Trade names:
APOC #133 Rubberized Flashing Cement
APOC #365 Rubberized Flashing Cement
APOC #115 Black Gold Rubberized Flashing Cement
PC #801 Rubberized Flashing Cement
RX 4100
Tri Built SBS Premium Roof Cement
Tri Built Ultimate Rubberized Cement
Collis AW Rubberized Flashing Cement
RoofCheck AW Rubberized Flashing Cement
HP 25
RSG SBS Modified Flashing Cement
TopShield All Weather Rubberized Cement
Thickness:
See Description Below.
Specification:
ASTM D 4586 Type I and ASTM D 3409
Description:
Asbestos free, asphalt based trowelable rubberized flashing cement for all types of roof and
foundation applications. Apply with a putty knife or trowel, filling all fissures, joints and
gaps. Apply at an approximate rate of 1/8" thick; 1 gal/12 1/2 sq. ft. When used on a bonded
or warranted roof system, follow instructions of that application system.
Container Size:
10-1/2" oz. tube and 1, 3, 5 gallons. Note all precautions on container.
Systems Approvals:
Methods of application and quantities shall comply with the specific Roof Assembly, Product
Control Notice of Acceptance.
Trade names:
APOC #400 Sunbrite AP#400
Gardner Silver Shield #6290-GA
#5180-A (Black Jack)
Thickness:
See Description Below.
Specification:
TAS 138-95
Description:
A highly reflective, water based, aluminum emulsion roof coating for use over BUR roofs,
Cap Sheets, Modified Bituminous Membranes and Metal Roofs.
Container Size:
5, 55, 275 gallons.
Systems Approvals:
Methods of application and quantities shall comply with the specific Roof Assembly, Product
Control Notice of Acceptance.
Trade names: APOC #501 Superflash Neoprene AP# 501
Black Jack 1010
Thickness: See Description Below.
Specification: ASTM D 4586
Description: A solvent based neoprene to be used as a topical repair mastic over concrete, aged asphalt,
wood, metal, polyurethane foam, pitch pockets and granule surfaced cap sheets.
Container Size: tube, 1, 3, gallons. Note all precautions on container
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly, Product
Control Notice of Acceptance.
NOA No.: 18-0411.03
Expiration Date: 02/01/21
Approval Date: O1/03/19
Page 9 of 13
Trade names:
Leak Stopper
GA 031
Thickness:
See Description Below.
Specification:
ASTM D 4586
Description:
A solvent based, rubberized roof patch. A polyester reinforcing fabric is recommended when
sealing cracks.
Container Size:
tube, 1, 3 gallons, 55 gallon drum
Systems Approvals:
Methods of application and quantities shall comply with the specific Roof Assembly, Product
Control Notice of Acceptance.
Trade names:
APOC #260 AMAZ'N STUFF Roof Patch AP #260
APOC #264
APOC #505 Patch N Seal
RX 905
APOC #515
HP 50
HP 75
RX #915
Thickness: See Description Below.
Specification: TAS 139-95
Description: An elastomeric roof patch applied to seal cracks on metal roofs, cement tiles, wood, structural
concrete roofs, aged smooth asphalt roofs, aged granule surfaced cap sheets, polyurethane
foam roofs, and aged roofs previously coated with asphalt and approved single ply
membranes.
Container Size: 1, 3, 5, gallons
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly, Product
Control Notice of Acceptance.
NOA No.: 18-0411.03
Expiration Date: 02/O1/21
Approval Date: 01/03/19
Page 10 of 13
Trade names: APOC 4252 FR
APOC # 252 Sunwhite AP #252
APOC #258 AP# 258
APOC #258 EPDM Renew It
APOC #247-Sun Shield, AP #247
APOC # 248 Arizona White, AP #248
RX #700
RX #500
Black Jack Ultra -Roof Elastomeric
Thickness:
Specification:
Description:
Container Size:
Systems Approvals:
MIAMI•DADE COUNTY
RMT670
Sta-Kool 780
HP 400
HP 420
HP 425
TopShield Premium Acrylic Coating
See Description Below.
ASTM D 6083
A reflective elastomeric coating membrane applied to the following substrates:
•Concrete:
*Single Ply PVC:
•Single Ply PVC (weathered):
•Single Ply EPDM:
*Single Ply Hypalon:
•Single Ply Hypalon (weathered):
*Granule Surfaced SBS Mod Bit:
•Smooth Surfaced SBS Mod Bit:
•Granule Surfaced APP Mod Bit:
•Spray Polyurethane Foam Systems:
•Galvalume:
•Galvanized Steel
•Kynar Coated Metal:
*Single Ply BUR: Apply a Base Coat at a minimum rate of 1 '/a gal per square and a
finish coat at 1 '/2 gal per square.
1, 5, 55 and 275 gallons
Methods of application and quantities shall comply with the specific Roof Assembly, Product
Control Notice of Acceptance.
NOA No.: 18-0411.03
Expiration Date: 02/01/21
Approval Date: 01/03/19
Page 11 of 13
Trade names: APOC #545 AP#545
RX #900
HP 475
Thickness: See Description Below.
Specification: ASTM D 6083
Description: A solvent based, SEBS coating for use over the following substrates:
• Galvanized metal: Apply minimum one coat of 250 primer followed 2 coats applied at
1 gallon per square, per coat, for a total rate of 2 gallons per square.
Container Size: 1, 5, 55 gallons
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly, Product
Control Notice of Acceptance.
Trade names: APOC #585
BJ #5576
EternaKote #5570
RX #985
TopShield White Silicone Coating
Thickness: See Description Below.
Specification: ASTM D 6694
Description: A single component, high solids content, cold liquid -applied elastomeric silicone
waterproofing membrane that is rolled, brushed, or spray applied at an application rate of:
*Galvanized Steel: Apply at a minimum rate of 1.5 gal./100 ftZ to 4 gal / 100ft2
*Granular SBS Mod Bit: Apply at a minimum rate of 1.5 gal./100 ftZ to 4 gal / 100ftZ
•Concrete: Apply at a minimum rate of 1.5 gal./100 ftZ to 4 gal / I00ftZ
•Single Ply EPDM: Apply at a minimum rate of 1.5 gal./100 ftZ to 4 gal / 100ftZ
•Spray Applied Polyurethane Foam: Apply at a minimum rate of 1.5 gal./100 ftZ to 4 gal /
100ftZ
Container Size: 5 and 55 gallons
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly, Product
Control Notice of Acceptance.
APOC #585, BJ #5576, EternaKote #5570, RX4985, and TopShield White Silicone Coating
are not approved as and shall not be used as a waterproofing system as required by the Florida
Building Code section 1519.16
NOA No.: 18-0411.03
Expiration Date: 02/01/21
Approval Date: 01/03/19
Page 12 of 13
LIMITATIONS:
1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire
rating of this product.
2. Gardner Asphalt products shall not be applied in inclement weather conditions.
3. The products listed herein are components of roof assemblies and are approved for use with roof assemblies that
list any of the products listed herein as part of their roof assemblies Notice of Acceptance.
4. All products listed herein shall have an unannounce follow-up quality control program from an approved listing
agency. Follow up test results shall be made available to Product Control upon request.
5. Change in materials, use, or manufacture of any of the products listed herein shall be cause for termination of this
Notice of Acceptance.
6. Gardner Asphalt Corporation products shall be applied in accordance with manufacturer's published application
instructions.
7. All approved products listed herein shall be labeled in compliance with TAS 121 and shall bear the imprint or
identifiable marking of the manufacturer's name or logo and following statement "Miami -Dade County Product
Control Approved" or the Miami -Dade County Product Control Seal as shown below.
MIAMMADE COUNTY
END OF THIS ACCEPTANCE
NOA No.: 18-0411.03
Expiration Date: 02/01/21
Approval Date: 01/03/19
Page 13 of 13