HomeMy WebLinkAboutPRODUCT APPROVALSn� II
0 0 g E
acts Home tng In I User Reg5 a0on Hot Tapia I Submit Su ehage Stars R naers I Publications contact Us BOO Site Map Units , SearrL �
Florida�� j".2F COPY
r�� '. ) Product Approval
i USER: PUBIIc Uzer
r C1(��{1 `� 0 eD
Pro,luct Aoom,l Men > Pmaud or Aoollra['on Sear[b> App❑ OnDBG �� O
�• Code Ve sonpe 20170on R6 RECEIVED 4%C0Unty
Application Status Approved MAR 0 4 2019
Comments
Archived
Product Manufacturer
CONCEALEd ffj&8ATTACHMENTS
ARETHE RESPONSIBILITY OF THE
CONiRACTORORRECORD
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
ST. Lucie
(]
Tri-Built Materials Group, LLC
PO Box 70
Rutherford, NJ 07070
(800) 516-1485
david.miz@tribuiltmg.com
THESE PLANS AND ALL PROPOSED WORK
David Ruiz ARE SUBJECTTOANY CORRECTIONS
david.ruiz@tdbuiltmg.(REQUIRED BY FIELD INSPECTORSTHAT
MAY BE NECESSARY IN ORDER TO
David Ruiz COMPLY WITH ALLAPPLICABLE CODES.
250 Route 17 North
East Rutherford, NJ 07073
(201) 842-2449
david.wiz@tribuiltmaterlaisgroup.com
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Robert Nieminen
PE-59166
UL LLC
07/18/2020
John W. Knezevich, PE
OO Validation Checklist - Hardcopy Received
FL16048 R6 COI 2017 01 COI N'em'nen odf
ASTM D1970
2015
ASIM G155
2005
FM 4474
2011
FRSA/TRI April 2012 (04-12)
2012
UL1897
2012
Product Approval Method Method 1 Option D
Date Submitted 09/25/2017
Date Validated - 10/01/2017
Date Pending FBC Approval 10/03/2017
Date Approved 12/12/2017
Summary of Products
fI
FL V
Model, Number or Name
Description
16048.1
TRI-BUILT Roof Underlayments
Self -adhering, modified bitumen roof underlayments
Limits of Use
Installation Instructions -
Approved for use in HVHZ: No
FL16048 R6 II 2017 09 FINAL ER TRI-
Approved for use outside HVHZ: Yes
BUILT UNDERLAYMENTS FL16048-R6 odf
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-150
Created by Independent Third Party: Yes
Other: 1.) The design pressure noted herein pertains to use
Evaluation Reports
of foam -on the systems overtop the self -adhering
FL16048 R6 AE 2017 09 FINAL ER TRI-
underlayment for one particular application. See ER Section
BUILT UNDERLAYMENTS FLS6048-R6.odf
5.6.4 for details. 2.) Refer to ER Section 5 for other Limits of
Created by Independent Third Party: Yes
Use.
Concoct Us :: 2601 Blair Srone Road, Tdllabassee FL 32399 Phone: 850-48]4824
The State of Florida is an vVeio employer Coovdaht 2007-2013 State of Florida.:: Pdvan Statement :: Accessibilav statement :: Refund Statement
Under Florida law, email addresses are public records. if you do not want your e-mail address released In response to a publlo-records request, do not send electronic
mail ro this, entity. Instead, comact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Gapter 455, F.S. must provide the Department with an email address If may have
one. The emalls provided may be used for official communication with the licensee. However email addresses are public recmd. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available in the public. To determine If you are a licensee under Chapter
455, F.S., please clisk here .
Productapp^roval Ac¢pin:
F59 MgI91 2;
seCltritvntFTRlCV
r— i
r r •r r �� Mill
KIS Home I Log In I titer Reglatmtion Hot Topics I Submit Sumbarye state 6 Fam butanoos contact tie 180S Site Map Unta searh
Florida r PILE COPY 1 �l' uses: pub inpprova
_� LRECEIVED
Pronutt Aonmval Menu > Pmtlutt or Aoogdtion Search > Aooliweon Lis [> Application detail
FL# FL17022-R7 4 0019Application Type Revision
Code Version 2017 n Permitting
Application Status Approved SCANNED
BY
Comments 08/18/2017v. date reapply 08/21/17 St. Lucie County Archived ❑
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Pore Drive
Palm City, FL 34990
flvalidation@34
yahoo.com
FASTENERS OR ATTACHMETS N(772) tion@ a
ya hoo. com
ARE THE RESPONSIBIUTY OF
Cqg ACIi OR RECORD E
nze gnature Richard McKuhen t
flvalidatton@yahoo.com
Technical Representative Richard McKuhen ^•�
Address/Phone/Email 2160 SW Ponta On Q C — .D
Palm City, FL 3499
(772) 872-8034 �!'(��"��� "Fkensed
� A44
richard@emfab.ne[�iST. Y BUILDING, DI IONQuality Assurance Representative REVPLIANCE Address/Phone/Email REVDAT
Category Roofing PLAIT MUST BE KEPT 1 OBSubcategory Metal Roofing SITEECTION(S) WILL ADECompliance Method Evaluation Report frotered Architect or Hosed
Florida Professional Engineer
❑ Evaluation Report - Hardmpy Received
Florida Engineer or Architect Name who developed LOCKE BOWDEN
the Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R. Priest, P.E.
ID Validation Checklist - Hardcopy Received
Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr odf
Referenced Standard and Year (of Standard) Standard yem
TAS 125 2003
UL 1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
THESE PLANSAND ALL PROPOSED WORK
ARE SUBJECTTO ANY CORRECTIONS
REQUIRMAY BE BY
IN ORDER TOOT
COMPLY WITH ALL APPLICABLE CODES.
Product Approval Method Method 1 Option D
Date Submitted 08/18/2017
Date Validated 08/25/2017
Date Pending FBC Approval 08/28/2017
Date Approved 10/10/2017
Summary of Products
FL tF
j Model, Number or Name
Description
17022.1
1 - "SV Crimp" (116)
26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel
mechanically attached to 15/32" plywood or Wood Deck with
fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL17022 R7 11 FL 17022.1 5 V CRIMP ssr odf
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions. Install the
assembly in compliance with the installation method listed in
FL17022 R7 AF F 1702 1 5 V CRIMP ssr.odf
Created by Independent Third Party: Yes
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.2
2 - "5V Crimp" (116)
0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof
panel, mechanically attached to 15/32" plywood or Wood
Deck with exposed fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ; No
FL17022 TI FL 17022.2
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ Table A
Evaluation Reports
Other: Refer to evaluation report for conditions.lnstall the
FL17022 R7 AF FL 17022,2 5 V CRIMP 0,032
assembly in compliance with the installation method listed in
ALUM ssnodf
this report and applicable code sections of FBC. Refer to
Created by Independent Third Party: Yes
manufacturer's installation instructions.
17022.3
3 - "1.5" Mechanical Seam" (RS)
1.5" rib height, 16" wide, 24 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with dips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.3 1.5 MECHANICAL
Approved for use outside HVHZ: Yes
Impact Resistant: No
seam 240a ssr.ndf
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and
Evaluation Reports
limitations of use. Install the assembly in compliance with
FL17022 R7 AE FL 17022.3 1.5 MECHANICAL
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
seam 24aa ssr odf
Created by Independent Third Party: Yes
Instructions.
17022.4
4 - "1.5" Mechanical Seam" (RS)
1.5" rib height, 16" wide, 0.032" aluminum, standing seam
roof panel mechanically attached to 15/32" plywood or Wood
Deck with clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.4 MECHANCCAL SEAM
Approved for use outside HVHZ: Yes
A �MIi� NVM ssnodf
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and
Evaluation Reports
limitations of use. Install the assembly in compliance with
FL17022 R7 AE FL 17022A MECHANCCAL SEAM
ALUMINUM ssr.odf
the installation method listed In this report and applicable
code sections of FBC. Refer to manufacturer's installation
Created by Independent Third Party: Yes
Instructions.
17022.5
5 - "1 in. Nail Strip" (RS)
1" rib height, 16" wide, 26gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.5 1,0 NAILSTRIP sscndf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Parry: Yes
Design Pressure: +N/A/ Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
FL17022 R7 AE FL 17022.5 1,0 NAILSTRIP ssrodf
Created by Independent Third Party: Yes
limitations of use. Install the assembly in compliance with
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
17022.E
6 - "1 in. Nail Strip" (RS)
1" rib height, 16" wide, 0.032" aluminum, standing seam
roof panel mechanically attached to attached to 15/32"
plywood or Wood Deck with fasteners,
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
EL17Q22 R7 II FL 17022.6 1.0 NAIL STRIP 0,032
ALUM sscpdf
Approved for use outside HVHZ: Yes
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ Table A
Other: Refer to evaluation report for conditions and
Created by Independent Third Party: Yes
Evaluation Reports
limitations of use. Install the assembly in compliance with
FL17022 TR P 0,032
ALUM ssnpdf
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
Created by Independent Third Party: Yes
Instructions.
17022.7
7 - "1.5in. Nail Strip" (RS)
1.5" rib height, 19" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.7 1,5 Nail Strip 26GA ssr odf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr odf
Created by Independent Third Party: Yes
limitations of use. Install the assembly in Compliance with
the installation method listed In this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
17022.8
8 - "EMAX Rib" (R5)
29 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
EL12022 R7 li FIL 177022.8 FMAX R'b ssrodf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
EL17022 R7 AE FL 177022.8 EMAX Rib ssr odf
limitations of use. Install the assembly in Compliance with
Created by Independent Third Party: Yes
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's Installation
Instructions.
17022.9
9 - " PBR MAX" (RS)
26 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 If FL 17022,9 PBR RIB ssr odf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
FL17027 R7 AF FL 17022,9 PBR RIB ssrodf
limitations of use. Install the assembly in compliance with
Created by Independent Third Party: Yes
the Installation method listed In this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
Context Us :: 2601 Blab Stone hood. Tallahassee FL 32399 Phone: 850- 87-1824
The State of Florida is an AA/M employer. Ceovdght 2007-2013 State of Florida. :: FrI statement :: Ade5516i1ity, statement :: Behind statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a publlorewrds request, do not send electronic
malI to MIS entity. Instead, onmad Me office by phone or by traditional mall. If you have any quesnons, please contatt 850.487.1395. *Pursuant to Section
455.275(1), Hodda Statutes, eHecfive October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If May have
one. The emails provided may be used for official Communication with the licensee. However email addresses are public retard. If you do not wish M supply a
personal address, please provide the Department with an email address which can be made available ro the public. To determine If you are a licensee under Chapter
455, F.S., please click bLe .
Predad Approval Adepts:
FW piig—�i ® "d_
SCcurty"IFT,ICS
Palm City, Fl. 34990
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min.15/32" plywood or
Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.)
Rib Height 1"
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.) thru
bottom of support.
Adhesive/Sealant : Bostik 915'" Chem -Chalk one component, polyurethane adhesive with
3/16" continuous bead application along base of male rib vertical flange at each panel
seam.
Underlayment: To be compliant with FBC Sec 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
Install Details: Table A Allowable Loads
METHOD i
METHOD 2
DESIGN PRESSURE*
-86 PSF Main. field
-97.25 PSF Perimeter
FASTENER SPACING
6" O.C.
6" O.C.
SEAM ADHESIVE
Not required
3/16" continuous bead
(see details)
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527
UL 580-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2
1
EQUIVALENCY: UL1897-04 is equivalent to -Test Standard UL1897-12. *i7acinn Praccura marnin of cafWv 9 • t
Certificate of Independence:
Locke Bowden, P.E. does not have, not will acquire a
under this evaluation.
Locke Bowden, P.E. is not owned, operated, or contr
report.
manufacturing or distributing products
or distributing products under this
' • '•
seal
% �'• STATE OF
All
Limitations:
1. Undedaymentto be compliance with current Florida Building Code (FBC)2017 61'ed..
2. Minimum slope to be compliant with Florida Building Code 2017 V, ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method:1-D
4. Engineering analysis for "project specific approval by local authorities w(urisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 61' ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural
Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel -Details
16"
Panel Profile
16" o.c.
—F_
3/4"
—t
Deck:
-15/32" or greater Plywood, or
- Wood plank
Integral Snap Lock
For METHOD 2:
Apply 3116" Bead Bostik 916^ Sealant
Continuous Along Male Rib Vertical Flange
\V
Fastener
#10 X 1" Min. per Table "A"
Pancake Head Wood Screw
(Typical Fastening Pattern Across Width)
1"
FL 17022.5
1.0 Nail Strip (26GA Steel),16" Wide Roof Panel - Details
151' or greater Plywood, or
- Wood plank
G9 C+G.Ior
Isometric View
rvl nrou 1w c
Apply 3116" Bead Bostik 916T Sealant
Continuous Along Male Rib Vertical Flange
(Refer to Table "A")