Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
GENERAC PAPERWORK
16/20/22 kW INCLUDES: FILE COPY MAR 0 5 2019 ST. Lucie CounEY. Permltting • True Power- Electrical Technology • Two Line LCD Multilingual Digital Evolution- Controller (English/Spanish/ French/Portuguese) • Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 5 for Details. • Electronic Governor • Standard Wi-Fi- Remote Monitoring ST.LUCIE COUNTY PLAN REVIEW BLDG: DATE ELE DATE—`% -C) PLUMB: • System Status & Maintenance Interval LED Indicators DATE: • Sound Attenuated Enclosure MECH: • Flexible Fuel Line Connector DATE: • Dfrect-To-Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation • 5 Year Limited Warranty • Listed and Labeled by the Southwest Research Institute allowing installation as close as 18' (457 mm) to a structure.` *Must be located away from doors, windows, and fresh air intakes and in accordance with local codes. hops://aswts.swfLOTIA'baWDrrecloiyOf istedPmducisl ConsWctionlrMusey/973_DoC_204 13204-01-01 Rav9.Ptl1 FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the had of Generac's success in providing the most reliable generators possible. Generac's G-Force engine lineup offers added peace of mind and reliability for when you need A the most The G-Farce series engines are purpose built and designed to handle the rigors of Wended run times in high temperatures and extreme operating conditions. O TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed WAG systems. O TESTCRRERIA: V PROTOTYPE TESTED V NEMAMGI.22 EVALUATION V SYSTEM TORSIONAL TESTED V MOTOR STARTING ABILITY GENERAC® GUARDIAN° SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating Models G007036-1, G007037-1 (Aluminum - Bisque) -16 WV 60 Hz Model G007D35-1 (Aluminum - Bisque) -16 kW 60 Hz Models 0007039-1, GOD7038-1 (Aluminum - Bisque) - 20 kW 60 Hz Models G007043-2, G007042-2 (Aluminum - Bisque) - 22 kW 60 Hz SCq \e yNFO _,C C �I �Unty 'GENERAC' c (S)US VIl�� LISTED Q + Note: Cut ceNficabon only applies to unbundled units and wits packaged with limited circuit switches. Units packaged with the Smart Switch are UL cemfied In the USA only. O SOUD-STATE, FREQUENCY COMPENSATED VOLTAGE BEGULA77ON: This state-of-the-art power maximizing regulation system is standard on all Generac models. O provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-malching the surge loads to the engine. Digital voltage regulation at ±1 %. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides pads and service know-how for the entire unit, from the engine to the smallest electronic component. O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line Includes its own transfer systems and controls for total system compatibility. O MOBILE LINK"' REMOTE MONITORING: FREE with every Guardian Series HomeshaGENERAC word husing aasmant hone,ows a to monitor PC. E silt' a c ss infonerntoo romsuch as the re Incur thecurrent � "I � wodd using a sntar�hone, tablet or PC. Easily access infannation such as the current PROMISE operating status and maintenance alerts. Conned your account to your authorized service dealerfor fast fdendly and proactive service. Vith Mobile Link, you are taken care of before �m the next power outage. GENERAC 16/20/22 W features and benefits Engine • Generac G-Force design Maximizes engine "breathing" for Increased fuel efficiency. Plateau honed cylinder walls and plasma moly • "Spiny-lok" cast iron cylinder walls • Electronic Ignition/spark advance • Full pressure lubrication system • Low all pressure shutdown system • High temperature shutdown rings helps the engine ran cooler, reducing oil consumption resulting in longer engine life. Rigid construction and added durability provide long engine life. These features combine to assure smooth, quick starting every time. Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. Shutdown protection prevents catastrophic engine damage due to low oil. Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to _-�1% prevents damaging voltage spikes. • UL2200listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers your vital electrical loads to the energized source of power. • NEMA 3R Can be installed Inside or outside for maximum flexibility. • Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. Evolution'" Controls • Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65%dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory delauIt setting of five (5) seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable seizing for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoorair temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift-oul front for easy access to all routine maintenance Items. Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18, (457 mm) away from a building. GENERAC 16/20/22 kW features and benefits Installation System • 1 If (305 mm) flexible fuel line connector Absorbs any generator Vibration when connected to rigid pipe. • Direct -to -dirt composite. mounting pad. Complex lattice design prevents setting or sinkingof the generator system. • Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. Remote Monitoring • Ability to view generator status Monitor your generator via your snutphone,tablet, or computer at any time via the Mobile Unk application for complete peace of mind • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours • Ability to view generator maintenance information Provides maintenance information for your specific model generator when scheduled maintenance is due • Monthly report with previous month's activity. Detailed monthly reports provide historical generator information ' • AbilityroView generator battery information Built Inbattery diagnos0csdisplaying current state ofthe battery • Weather information Provides detailed local ambient weather Conditions for generator location GENERAC 16/20/22 kW switch options Limited Circuits Switch Features • 16 space, 24 circuit, breakers not included. •. Electrically operated, mechanically -held contacts for fast, positive connections • Rated forall classes of load,100% equipment rated, both inductive and resistive. • 2-pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Rated for both copper and aluminum conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Multi listed for use with I'standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effective install. Dimensions Height width Depth H1 H2 W1 W2 in 26.75 30.1 10.5 13.5 6.91 mm 679A 764.3 266.7 343.0 175.4 Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 210-#14 ZM-#14 Service Rated Smart Switch Features • Includes Digital Power Management Technology standard (DPM). • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to four more large (240 VAC) loads can be managed when used in conjunction with Smad Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load,100% equipment rated, both Inductive and resis- tive. • 2-pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/Ul- 3R aluminum outdoor enclosure allows for Indoor or outdoor mount- ing flexibility. Dimensions "1 Amps 111211.10 Open TruuiOon Service Rated Height Width Depth HI H2 Wl W2 In 1 26.75 30.1 10.5 13.5 6.91 mm 1 679.4 764.3 266.7 343.0 175A Model GU07036.1 (1liffl) ,NO. or I Pales _^..__'.._�_ —� . 2 current Rating (Amps) _ 100 _ _ Vallage natiag_(VAcj a 72d1240; 12. Utility Voltage Monitor (Fixed)' -Pick-up 80% -Dropout 65% Relu(� mlo Wiliry' �—_____,_ _ _ epProx15sec4 _ j Eternises bl-weekly for 5 minutes' Standard L Dsled - ,� Sladdard Total Circuits Available 24 (Tandem Breaker Capa6lflies _ -_ � ' _ Atandems .�_,_ .v: Circuit Breaker Protected Available RMS Symmetrical 10,000 Fault Current @ 250 Valli `Function of Evolution Controller Exercise can be setto weekly or monthly I� Model GO07037.1 (16 kW)/6007039.1 (20 kw)/ G007043.2 (22 kw) _ 2e 6urmnl Rating(Amps) 20D Poinge Rating(VAC) Uffly Voltage Monitor (Flood)' fink -up 80% -Dmpour 65% _ _ _ Return to UtiOrye�»��_ y_zppioi. l3 tec Exercises bl-weekly for 5 minutes* Standard JUL tasted e_ `_____^_ StmdarN _ Enclosure Type NEIAWL 311 )Circml Breaker BrolecleU_ _ �2 Wg Range O MCM -#6 'Function of Evolution Controller Exercise can be set to weekly or monthly �J GENERAC 16/20/22 kW available accessories # Product' LP Fuel Level Monitor GDO5819-0 I26R Wet Cell Battery 6007102-0 1011IWanner G007103-1 Breather Warmer G005621-0 Alixifary Transfer Switch ----- - ---- Contact Kit-_ - - G007027-0 - Bisque ---------- (Standard on22kW)-- G00570M - Bisque PaintKd 0006485-0 Scheduled Maintenance KI G006873-0 Smart Management Module ---------`--�(50Amps) -- Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. M 1g the LP tanks fuel level is an important step in making sure your generator Is ready to ran during (pected power failure. Status alerts are available through a free application to notify when your LP ti is in need of a refill. Every standby generator requires a battery to start the system. Genemc offers the recommended 26R we cell battery for use with all air-cooled standby product (excluding PowerPacto). The pad warmer rests under the battery. Recommended for use if the temperature regularly falls below { 0 IF (-18 "C). (Not necessary for use with AGM -style batteries). Oil warmer slips direc8y overthe differ. Recommended for use if the temperature reguladyfalis below 0 °F' The breather warmer is for use In extreme cold weather applications. For use with Evolution controllers lonly in climates where heavy icing occurs. The auxiliary transfer switch contact kit allows the transfer switch to lockout a single large electrical load) you may not need. Not compatible with 50 amp pre -wired switches. ) The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a sleek, contoured appearance as well as offering protection from rodents and insects by covering the rifting hales located in the base. If the generator enclosure Is scratched or damaged, it is important to touch up the paint to protect from future corrosion. The paint ktt includes the necessary paint to property maintain or touch up a generator I enclosure. — — --- -- - - - -- - — - — - -- --- - -- -- - - -- - I Generac's scheduled maintenance kits provide all the hardware necassaryte perform complete routine ! maintenance on a Genemc automatic standby generator. - —1 Smart Management Modules are used in conjunction with the Automatic Transfer Switch to Increase its power management capabilities. It provides additional powermanagementilexibility notfound In any otherl power management system. dimensions & UPCs Dimension showrin approtima2. Defer to iratallelian annual for mddnnenslons DO NOT USE THESE DIMENSIONS FOR DWAItATION POaPOSES. LEF SiDEwEW 1°&e lnj MONrwEW Model UPC G007035-1 696471074161 G007036-1 696471074154 G007037-1 696471074178 G007038-1 696471074185 G007039-1 696471074192 G007042-2 696471074208 G007043-2 696471074215 GENE RAC® Generate Power Systems, Inc. ° S45 W29290 HWY. 59, Waukesha, W153189 ° generac.com 02018 Genemc Power Systems,Inc. All fights msewed.All specification are subjedta change mthoulmtke. Part No. 100000DO194-H (0/01118) • A, 16/20/22 kW specifications Generator Model G007035.1, G007036-1, G007038.1, G007039.1 0007042.2. G007043-2 G007037-1 (16 kW) (20 kW) (22 kW) -a-... _,._--- (Hzled 6dmumum Coninuous PowerOapaclly (fAL - Bated Madmum Continuous Power Capacity INS) 16,000Watts' 18.000 Watts' 19,500 Watts [Be dVallage248`_ �- _ _1 Bated Martimum Continuous Load Cunenl-240 Volts(LP/NG)� 66.7/66.7 83.3/75.0 91.7181.3 D161eaker_ (Taira Cir Main Line Circuit Breaker Line 70 Amp 90 Amp 100 Amp Number of Bolan Poles 2 2 2 Fated AC Frequency' — 60 Flt 60 Hz _ 6OHz. Prover Faclor 1.0 1.0 1.0 rBaRery Re4mrement (nolinclWed));__-��_ -�-f_ � ! �' 12 VoltsGroup26R 540 CCA Minimum or Grou 35AGM650CC_A Mnimum. Unit Weight(IoAlf) 409/186 448/203 466/211 [Dimensions (LxWzH)INmm .----------_.__ -_._ %1278xfi38x732-�_____ Sound output in dB(A) at 23 9 (7 on) wiN Generator opemtlrg al normal Iwtl•• 67 67 67 Type of Engine GENERAC G-Forte 1000 Series Displacement 999 cc 999 cc 999 cc � _ Afiffl w/�PasfIion Sleeve __-__ _ ri � � .._.._. 'Overhead 'Valve Arrangement � � Overhead Valve Valve Overhead Valve Ignitiotl System Solid -slate w/Magnetp__-_ Sohd-statew7 MAgne(c _ � Solid-state w/Magneto'.? Governor system Electronic Electronic Electronic gio_._ Slider 12 VDC 12VDC 12VDC Oiil Ca city lnGuding Fillet —= ��_ -�"`�—��'�- _�_,___.,,._ ___-- � 19'f/18L_ r T PPP_ 9.�. Approx_9':9 qt%1.8C ;_.� Approz-1 9q1/7i8L'. $ Operating rpm 3,600 3,600 3,600 Fuel Cunsumpl!on' '_^.__ Natural Gas ION (me/hi) t - 12 Load 218 (6.17) 204 (5.78)1 226 (6.45) Full Load 309 (8.75) _ 301I(8.52) 327(926), fit film •� ll - 12 Load. '. - 74 (203) [7.70] - 87 (2.37) (6.99]• 92 (2.53), [9.57] j Full Load 007(2.941(11.11]_ 130(3:56),[73�48]__,_- 192(3.90p[74.77] 1 Note: Fuel pipe musl6e sized for lull load. Requ9edfuel ppressure fa generatorfuel Intel at all load ranges -3.5-T water column (7-13 min mercury) for natural gas, 10-12'rvater column (19-22 mm mercury) far lP pas. For BTU wntent, muWpN fl3/hrx 2500 (IP) or 9eMx 1000 (NG). Far Megaloule wntenl muttip!y ma/hr x 93.15 M) or ma/hrx 37.26 (NG) Controls Two-L!ne Plain Ted Multilingual LCO Display Simple user interface for ease of operation. Mode BullonsAula.• r___ _ l____ _,.______ luilamatic3latl on Uglily lailme.7day exerciser,., �E Manual SNtl with starter control, unit stays on. If utility falls, transfer to load takes place Stops 16 it: is removed_OonUolSM iharger sl!Il gperale: Ready to fluNMaintenance Messages Standard _. ._____._____�__..____�....___ ,Engine Run Hours 1pdicaii�_oo : ,. _.... ._.. __. . .: �- -_ __. wSlandaN AuNAlamyMainterende'Lpps .. .. .• � , SO Events Ear]i'--"___",__;..�._._,_; ;.._.-; Engine Stan Sequence Cyclic cranking: 16 sec on, 7 rest (90 sec madmum dualion). $t'3tler Lock-ouL �_�,-Y ___._____-__�________`_ ____-`____,Stotler wnnotre2nga9eundl 5 see after engme M1as sloppip i 3mad Battery Charger Standard ;- __e.T__ ._,_______._..,�__ hanger faplVMiuing AC Wam n9 �'.. ,•,,�-., _.,_...,r _ _._, .._ _.__ ._.... .__._�._... --, ..Slandard— _.._ ._,,__�. ,_ . .ow Batiery/Battery Problem Protection and Battery Condition Indication Standard Standard---- _�_� _—__.,,—_ __—_—.._-,.�_._.__.,.___.___.___.. Wtoma6e ValUge Hegula(mnwilA Over and Under Voltage Prolediam ': - �- -- SlandaN , .'y - r trader-Frequency/Overlaad/8lepperOvercurtent Pmtectlan Standard ialely Fused/Fvse Problem Prolectiom ^; _' - :, ., _•. Standard' ' -" � __..�._. - call_,..'_._ aromatic Low Oil Pressure/High Oil Temperature Shutdown Standard IvarcrankrPvers eked(@72 F4yNm Sense lass Shutd'oim`.__:,�_._.�^_._...�___.___.�___.... ____--tandard. rli• �.__._=i �__ _._..'.�3 High engine Temperature Shutdown Standard _ _ _ ..:siadartl V ommon 5bmal Fault Capability Standard �, . r . ,------- Gift Site Selection and Preparation Section 3e Site Selection and Preparation Site Selection i 5ft(1.52 m) C 5ft(1.52 m) 3ft 3ft © I~ (0.91 m) O ]~(D 9 1 m) 3ft (0.91 m) OO y F Figure 3-1. Installation Clearances 001751 001789 ID Description Comments A Top of generator — B Front and end clearance Minimum Gear distances cannot include shrubs, bushes, or trees. C Rear clearance 181n (45.7 cm) minimum clearance per SwRI testing, labeling, and listing, unless state or local codes dictate otherwise. D Windows and openings No operable windows, doors, or openings in the wall are permitted within 5 8 (1.52 m) from any point of the generator. E Usting wall One -hour fire rated walls allow closer placement of the generator set. Confirm before installation. F Removable fence Removable fence panels for servicing cannot be placed less than 3 it (0.91 m) in front of the generator. G Overhead clearance 5 ft (1.52 m) minimum distance from any structure, overhang, or projections from the wall. DO NOT install under wooden decks or structures unless this distance is maintained. Installation Guidelines For60 Hz Air -Cooled Generators 11 Smart Management Modules (SMM) FEATURES GENERAC® ACCESSORIES Model G007000-0 UPC 696471070002 C UL US LISTED Generac's Smart Power Management System is designed to optimize the performance of a standby generator. The system can consist of up to 8 individual Smart Management Modules (SMM). Unlike other load management systems that depend on another control device, the SMM modules are actually self -aware and operate autonomously. Frequency is the true measure of generator engine performance and does not need to factor in increased ambient temperatures, elevation changes or generator fuel type. The modules monitor the frequency (Hz) of the power being produced by Generac's standby generators. If frequency falls below a certain threshold, the module will automatically follow a power management algorithm to reduce the chance of a generator overload condition. The modules can be set to a load priority between 1-8, or be set In a lock -out only mode for loads that just simply do not need to run In an outage. This reduces the minimum size of the generator for a more cost-effective solution. SMM SPECIFICATIONS Power Supply Source.. Contact Voltages......... Contactor Coil Voltage Coil VA Inrush ............. Coil VA Sealed............ Poles........................... Resistive Amps ........... F/L Inductive Amps ...... Locked Rotor Amps...... NEMA.......................... Enclosure Rating.......... Frequency Selectability GENERAC® (from Line input) ....220/240 VAC ........... 240 VAC ..................... 30 .................... 6.5 ....................... 2 ..................... 50 ..................... 40 ..................1180 ..................... 3 R ............... UL 50 ...50 Hz/ 60 Hz a GENERAL® IIIIM Smart Management Modules (SMM) Dimensions and UPC Ia -- W1 1 Model 0007009-0 Height(tNmm) H1 6.171156.8 H2 2.36/60 Width (/mm) W1 7.06/179.4 W2 4.72/120 Depth (iNmm) 3.7/94 Weight(6/kg) 2.06/0.94 Shipping Weight(ih/kg) 2.44/1.11 UPC Code 696471070002 0 0 0 SMM Controls (located behind the module cover) //���� LED ON= LOAD CONNECTE➢ LEI) FLASH iS = LOAD SHED PRIORITY L06N0xr LEolusxBs=aoMmLOCKOUT s LOAD ON GENERATOR LED FLASN 65 v GEH LOAD LOCKOUT7 LED OFF= NO MODULE POWER ® ® 0 0-� 0 LOCKOUT DISABLED Priority Dial (A) Sets module priority Lockout Switch (B) Prevents load from operating when system Is operating under generator power. Test Button (C) Disables contactor output for aspecified time. LED (0) Provides module status with easy viewing through the Iodemal viewing window located in the upper right comer of the module. GENERAC® GeneraoPower Systems, Inc.•S45W29290HWY. 59,Waukesha, Wl53189•generao.com C201 B Genera[ Power Systems,Inc. AT dehts reserved. Al speclficomns are su0lact to Mango without notice. Pad No. 10000029407 rev B (IVIN18) Site Selection and Preparation Install the generator set, in its protective enclosure, outdoors where adequate cooling and ventilating air is always available (Figure 3-1). Consider these factors: • The installation of the generator must comply strictly with ICC IFGC, NFPA 37, NFPA 54, NFPA 58, and NFPA 70 standards. • Install the unit where air inlet and outlet openings will not become obstructed by leaves, grass, snow, etc. If prevailing winds will cause blowing or drifting, consider using a windbreak to protect the unit. • Install the generator on high ground where water levels will not rise and endanger it. This unit should not operate in or be subjected to standing water. • Allow sufficient room on all sides of the generator for maintenance and servicing. This unit must be installed in accordance with any local, state, or national codes for minimum distances from other structures. • Clearance from the ends and front of the generator must be 3 ft (0.91 m). This includes shrubs, bushes, and trees. Clearance from the back of the generator must be a minimum of 18 in (457 mm). Clearance at the top should be a minimum of 5 ft (1.52 m) from any structure, overhang, or projections from the wall. • DO NOT install under wooden decks or structures unless there is at least 5 ft (1.52 m) of clearance above the generator. • Install the unit where rain gutter down spouts, roof run-off, landscape irrigation, water sprinklers, or sump pump discharge does not flood the unit or spray the enclosure, including any air inlet or outlet openings. • Install the unit where services will not be affected or obstructed, including concealed, underground, or covered services such as electrical, fuel, phone, air conditioning, or irrigation. This could affect warranty coverage. • Where strong prevailing winds blow from one direction, face the generator air inlet openings to the prevailing winds. • Install the generator as close as possible to the fuel supply to reduce the length of piping. REMEMBER THAT LAWS OR CODES MAY REGULATE THE DISTANCE AND LOCATION. In the absence of local codes regarding placement or clearance, we recommend following these guidelines: — Install the generator as close as possible to the transfer switch. REMEMBER THAT LAWS OR CODES MAY REGULATE THE DISTANCE AND LOCATION. — The generator must be installed on a level sur- face. The generator must be level within a 0.5 in (13 mm) all around. — The generator is typically placed on pea gravel, compacted soil, crushed stone, or a concrete pad. Check local codes to see what type is required. If a concrete pad is required, all appli- cable codes should be followed. Installation Guidelines for Stationary Air -Cooled Generators NFPA 37 is the The National Fire Protection Association's standard for the installation and use of stationary combustion engines. Its requirements limit the spacing of an enclosed generator set from a structure or wall (Figure 3-1). NFPA 37, Section 4.1.4, Engines Located Outdoors: Engines, and their weatherproof housings if provided, that are installed outdoors shall be located at least 5 ft (1.52 m) from openings in walls and at least 5 ft (1.52 m) from structures having combustible walls. A minimum separation shall not be required where the following conditions exist: 1. The adjacent wall of the structure has a fire resistance rating of at least one hour. 2. The weatherproof enclosure is constructed of noncombustible materials and it has been demonstrated that a fire within the enclosure will not ignite combustible materials outside the enclosure. Annex A — Explanatory Material A4.1.4 (2) Means of demonstrating compliance are by means of full scale fire test or by calculation procedures. Because of the limited spaces that are frequently available for installation, it has become apparent that exception (2) would be beneficial for many residential and commercial installations. With that in mind, the manufacturer contracted with an independent testing laboratory to run full scale fire tests to assure that the enclosure will not ignite combustible materials outside the enclosure. NOTE: Southwest Research Institute testing approves 18 in (457 mm) installation minimum from structure (Figure 3-1, C). Southwest Research Institute is a nationally recognized third party testing and listing agency. The criteria was to determine the worst case fire scenario within the generator and to determine the tgnitability of items outside the engine enclosure at various distances. The enclosure is constructed of non-combustible materials, and the results and conclusions from the independent testing lab indicated that any fire within the 12 Installation Guidelines For 60 Hz Air -Cooled Generators Site Selection and Preparation generator enclosure would not pose any ignition risk to nearby combustibles or structures, with or without fire service personnel response. PATE I W QM MA>Q-® PATE 2 Po UM NA*-- Ag1E 3 q7 CKM MA)Q-- xmE 4 00 am KA*KA*. — PAIE 6 W QM IUUp— xoTE 7 GA CIIA3. aA)0-- NOTE � Do atAa dAw=-- GBMC PUM S7STM IRE WAMM a M USA 630 M267 oo215E Figure 3-2. Southwest Research Institute Marking hHp✓Avww.swd orgNorgldolfre/listlablilstprod/director htm Based on this testing and the requirements of NFPA 37, Sec 4.1.4.1.2, the guidelines for installation of the generators listed above are changed to 18 in (457 mm) from the back side of the generator to a stationary wall or building (C). For adequate maintenance and airflow clearance, the.area above the generator should be at least 5 ft (1.52 m) with a minimum of 3 ft (0.91 m) at the front and ends of the enclosure. This includes trees, shrubs, and bushes. Vegetation not in compliance with these clearance parameters could obstruct air flow. In addition, exhaust fumes from the generator could inhibit plant growth. See Figure 3-9 and the installation drawing within the owner's manual for details. Site Preparation • Locate the mounting area as close as possible to the transfer switch and fuel supply. • Leave adequate room around the area for service access (check local code), and place high enough to keep rising water from reaching the generator. o Choose an open space that will provide adequate and unobstructed airflow. • Place the unit so air vents won't become clogged with leaves, grass, snow, or debris. Verify that exhaust fumes will not enter any building through eaves, windows, ventilation fans, or other air intakes (see Site Selection). • Select the type of base, such as —but not limited to —compacted soil, gravel, or concrete, as desired or as required by local laws or codes. Verify your local requirements before selecting. Material Sufficient for Level Installation I � Automatic start-up. Disconnect utility power and render unit inoperable before working on unit. Failure to do so will result in death or serious injury. — (000191) 0 ;=a�LS 1 b OUNAsphyxiation. Running engines produce carbon monoxide, a colorless, odorless, poisonous gas. Carbon monoxide, if not avoided, will result in death or serious injury. (000103) NOTE: If the generator is not set to OFF, it can crank and start as soon as the battery cables are connected. If the utility power supply is not turned off, sparking can occur at the battery posts and cause an explosion. Prepare a rectangular area approximately 5 in (127 mm) deep (A) and approximately 6 in (152 mm) longer and wider (B) than the footprint of the generator. Verify that the surface where the generator will be mounted is compacted, leveled, and will not erode over time. A concrete pad can be poured if desired or required. O ISO=0�1 IrC=4�1 Ilr� oa Ir_.=G'U I�C�O�1 IBC=��1 000856 Figure 3-3. Compacted Soil or Gravel Pad NOTE: If a concrete pad is required, follow all applicable federal, state, or local codes. Installation Guidelines For60 HzAir-Cooled Generators 13 Site Selection and Preparation Transportation Recommendations Use a suitable cart or equipment to carry the generator, including the wooden pallet, to the installation site. Place cardboard between the hand cart and the generator to prevent any damage or scratches to the generator. IMPORTANT NOTE: Do not lift, carry, or move the generator by grasping the louvers. Doing so may bend or damage the sheet metal. Placement on Roofs, Platforms, and Other Supporting Structures Where required to place the generator on a roof, platform, or other supporting structure, like a deck, the generator shall be placed in accordance with the requirements in NFPA 37, Section 4.1.3. The generator can be located 18 in (45.7 cm) from structures having combustible walls and 5 ft (1.52 m) from any operable opening in the structure. The surface beneath the generator and beyond shall be noncombustible to a minimum distance of 12 in (30.5 cm). Consult with the local Building Inspection Department or Fire Department to determine which noncombustible materials are approved for installation. 14 Installation Guidelines For 60 Hz Air -Cooled Generators