HomeMy WebLinkAboutLOAD CALCULATIONOptional Load Calculation
Heat Larger Than Air
0,23G !a SF x 3VA Living Only
(2) Small appliance ckts @ 1500VA each
Refrigerator @ 1500
Refrigerator @ 1500
Freezer @ 1500
Washing Machine @ 1500
Dishwasher @ 1500
Disposal @ 1500
Mini Sewer @ 1500 LEIVED
Clothes Dryer @ 5000
•Range @ 120000 5 2019
Water heater @ 4500
Fixed microwave @ 150
Vacuum @ 1500 ounty, Permitting
Trash Compactor @ 1500
Pool Heater @'name plate'
Spa @'name plate'
Motors 746VA per HP P,5CA
Garage Door Opener
1) Total
2) First 10 KVA of general load @ 100%
3) Subtract line 2 from 1
4) Multiply line 3 @ 40%
5) Add lines 2 and 4
6) 60/50amp breaker for heat (10000)
7) 40/30amp breaker for heat (5000)
s) Total heat -Add lines 6 and 7
9) Multiply line 8 @ 65%
10) Add lines 5 and 9
11) Divide line 10 by 240
Summary:
Line 10 is the total KW
Line 11 is the total Amps
i J
3000
- ►.5UU
14500
- 15v0'
- 3 O
= 13YC6
153G R
= ly000
- IUoGQ
RIaQ15?
SCANNED
BY
St. Lucie County
ST.LUCIE COUNTY
PLAN REVIEW
BLDG:
DATE:
ELE
DATE'-
PLUMB.
DATE:
MECH:
DATE:
(Generator Size Needed)
(Breaker Size Needed)
FILE C®Py