HomeMy WebLinkAboutLOAD CALCULATIONOptional Load Calculation
Heat Larger Than Air
a(00 7 SF x 3VA Living Only
(2) Small appliance ckts @ 1500VA each
Refrigerator @ 1500
Refrigerator @ 1500
Freezer @ 1500
Washing Machine @ 1500
Dishwasher @ 1500
Disposal @ 1500
Mini Sewer @ 1500
Clothes Dryer @ 5000
Range @ 12000
Water heater @ 4500
Fixed microwave @ 1500
Vacuum @ 1500
Trash Compactor @ 1500
Pool Heater @ 'name plate
Spa @ 'name plate —
Motors 746VA per HP W E.1j
Garage Door Opener
RECEIVED
MAR 0 6 Z0119
ST. Lucie County, Permitting
1) Total
2) First 10 KVA of general load @ 100%
3) Subtract line 2 from 1
4) Multiply line 3 @ 40%
5) Add lines 2 and 4
6) 60/50amp breaker for heat (10000)
7) 40/30amp breaker for heat (5000)
B) Total heat- Add lines 6 and 7
9) Multiply line 8 @ 65% .
10) Add lines 5 and 9
11) Divide line 10 by 240
Summary:
Line 10 is the total KW
Line 11 is the total Amps
3000
50D
- Isoa
-500
1506
= Lv� saw
- 1503
iv UC>0
7 7 9
= 391112
10000
SCANNED
BY
St. Lucie County
ST.LUCIE COUNTY PAN REVIEW
BLDG:
DATE:
ELE�
DATE 6`
PLUMB: —
DATE.— �
MECH:
DATE:—�
o.VLI A 2. (Generator Size Needed)
95t 6 (Breaker Size Needed)
FILE COPY