Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL122 BUS Home 1 Lag In I U.'Registagan 1 Hof Taptcs I Submit Surcharge 1 Stats a Facts I PubliraHons I Contest Us I BUS Site Map Links Search d u� °A Product Approval ' USER: Publi[ User e , y1p FILE COPY 'q RCe RW1u¢ ADeroval Menu > Applimtion Datail NP 9 p Fa ^'ni 6' FL# FL16027-R2 St<���90 1�%B SCANNED Application Type Revision 0/0 C116d BY Code Version 2017 ryPot St. Lucie County Application Status Approved Comments Archived Q Product Manufacturer Tri-Bullt Materials Group, LLC Address/Phone/Email _ PO Box 70 Rutherford, NJ 07070 JJ� I� L OR ATTACHMENTS(800) 516-1485 r IA A1 �rC CONCEALED FASTENERS kBETHERESPONSIBIIJTYOFTHE david.ruiz@tribuiltmg.com CONTRACTOR OR RECORD ST. LUCIE COUNTY BUILDING D SIO Authorized Signature David Ruiz REVIEWED FOR COMPLIANCE david.ruiz@tribuiltmg.c DATI D B PLANS D PERMIT MUST BE K P ON JOB Technical Representative David Ruiz SITE OR NO INSPECTION(S) WlkL BE MADE Address/Phone/Email 250 Route 17 North East Rutherford, NJ 07073 (201)842-2449 david.ruiz@tribuiltmaterialsgroup.com Quality Assurance Representative C Richard Schuman Address/Phone/Email 9050 Louisiana Street Merrillville, IN 46410 rich.schurman@alliedbuilding.com Category Roofing Subcategory Modified Bitumen Roof System _ Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Q Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report THESE PLANS AND ALL PROPOSED WORK ARE SUBJECTTO ANY CORRECTIONS Florida License PE-59166 T REQUIRED I Quality Assurance Entity UL LLC MAYBE NECESSARY IN ORDERS Quality Assurance Contract Expiration Date 10/06/2018 COMPLY WITH ALL APPLICABLE CODES. Validated By John W. Knezevich, PE 0 Validation Checklist - Hardcopy Received Certificate of Independence FL16027 R2 COI 2017 01 COI Nieminen Ddf Referenced Standard and Year (of Standard) Standard Year ASTM D6163 2008 ASTM D6164 2011 ASTM D6222 2011 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEV...gtFPmdYiNDWrxtft9YUwv%2fLXRbpak6f2jJGiymvhtbu40%3d%3d 3/3/19, 3:45 PM Page 1 of 2 FM 4470 FM 4474 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/25/2017 Date Validated 09/30/2017 Date Pending FBCAppmval 10/08/2017 Date Approved 12/12/2017 Summary of Products 2012 2011 A, .. FL# -_� `-Model,•Num1i ,... or Name'- _. ... .., ,... Description 16027.1 TRI-BUILT Modified Bitumen Roof SBS and APP modified bitumen roof systems Systems Limits of Use Installation Instructions!, Approved for use in HVHZ: No FL16027 R2 II 2017 09'FINAL Al ER TRI- Approved for use outside HVHZ: Yes BUILT MODBIT FL16027-R2 odf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.) The Design, Pressure noted in this application Evaluation Reports refers to one system. Refer to ER Appendix for all systems and FL16027 R2 AE 2017 09 FINAL ER TRI- max: design pressures. 2.) Refer to ER Section 5 for Limits of BUILT MODBIT FL16027-R2-pdf Use. 1 Created by Independent Third Party: Yes ContartUs :: 2601 Blair Stone Raad. Tallahassee FL 32399 Phone: 858-487-1824 The State of Honda is an AA/E80 employer. Conydoh0 2007-2013 State of Florida.:: Pnyao, Statement:: Accessibility Statement :: Refund Statement Under Honda law, email addresses are public records. If you do not want your a -mall address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any quaidons, please contact 850.487,1395.'Pursua at to Settion 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an ems 11 address If they have one. The ¢mails provided may be used for official cummunication with the licensee. However email addresses are public reetrd. If you do not wish to supply a personal address, please provide the Department with an email address which an be made available to the public To determine if you ere a licensee under chapter 455, F.S., please dick here . Product Approval Aorepts: lawl—I 1-1 IEt Ca;ita/ �sI ,:ilf?j r:f. ([7 r -t iz - � Try a.afJ ;yIj A �,r"tC:�:-i��i);i_�t •ir�.n/i nnm1 1 SCCUrltYMETRICS https://www.floridabuilding.org/pr/pr_app-dtl.aspx?param=wGEV --- qtFPmdYiNDWrxtftgYUwv%2fLXRbpak6f2jJGiyowhtbu4o%3d%3d 3/3/19, 3:47 PM Page 2 of 2 TRINITY I ERD ' ,- `,,' „°•,',; .`TABLE CIE-2:, WOOD 'DECKS -NEWCONSTRUCTION, REROOF,(TFAR-OFF)OR RECOVER 1 SYSTEM TYPE E;' NON -INSULATED, MECHANICALLY ATTACHED BASE'SHEET, BONDED ROOF COVER System Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP No. Base Fasteners Attach Base Ply Cap Ply (psf) Min. Inch Polyglass Elastobase, Polyglass Elastobase - Poly, Polyglass G2 Base, CertainTeed OMG Flat Bottom Plates (square) with , 12-Inch o.c. in 4-Inch lap and 12-inch. (Optional) One or SBS-AA, SBS- W-1 od at plywood at max. Glasbase, Firestone MB Base, JM Parma- Roofgrip #14, Dekfast Hex with Dekfast #14 o.c. in two, equally spaced, staggered more BP -AA or TA APP TA -52.5 24-inch spans Ply 28, Tamko Glass Base or GAFGLAS #75, or TruFast MP-3 with TruFast HD center rows APP-TA W-2 Min. 19/32-Inch at max. Polyglass Elastobase or Polyglass Dekfast Hex with Dekfast #14 orTru Fast MP-. 12-Inch o.c. in 4-inch lap and 12-Inch One or more 5BS- SBS-SA, APP- plywood - Elastobase Poly with poly top surface 3with TruFast HD two, equally spaced, staggered SA 5A,SBS-TA or -52.5 24-inch spans cen center rows APP-TA W-3 Min. 19/32-Inch at max. Polyglass Elastobase or Polyglass OMG Bottom Plates (square) with 12-Inch o.c. in 4-Inch lap and 12-inch (Optional) One or ,' , plywood Elastobase Poly Roofgrip #12 ofgrip in two, equally spaced, staggered more BP -AA or TA, A TA APP TA TA -60.C' 24-Inch Spans center center rows APP-TA Min. 19/32-Inch PolyglassElastobaseorPolyglass OMG Flat Bottom Plates (square)with c . 12-inch o. in 4-Inch lap and 12-inch One ormore5B5- SBS-SA, APP- W-4 plywood at max. Elastobase Poly with poly top surface Roofgrip #12 equallyspaced, staggered e SAtwo, SA, SBS-TA or -60.0' 24-inspans center rows center APP-TA ' "" • ^`TABLE if: WOOD DECKS -NEW CONSTRUCTION OR REROOF(TEnk-OFF) �SYSTEMrTVPE F:NON-INSULATED, BONDED ROOF C}OVER'�, System Deck Primer Roof Cover (Note 15) - MOP Joint Treatment Base Ply Ply Cap Ply No. (psf) W-5 Min. 15/32-inch plywood (Optional) ASTM D41 None SBS-SA (Optional)SBS-SA or SBS-SA,APP-SA, SBS-TA -90.0 at max. 24-inch spans p APP-TA or APPeTA W-6 Min. 15/32-inch plywood (Optional) ASTM D41 Plywood joints are covered with 4-Inch wide strips of TrlBuik SA TriBuilt SA 5B5 Base (Optional)SBS-SA or SBS-SA APP-SA, SBS-TA -97.5 at max. 24-Inch spans SBS Base, rolled Into place to create continuous bond. APP-TA or APPITA Exterior Research and Design, I.I.C. d/b/a Trinity HERD Evaluation Report A42970.10.12-R2 for FL36027-R2 Certificate of Authorization #9503 0 EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2:09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1,Page 8 of 26 15. Unless otherwise noted, refer to the followingreferencesfor bonded base, ply or cap sheet applications. TRINITY I ERD I `-TABLE1:TRI-BUILTROOFCOVERS Reference Layer Material Appllcation BP -AA Base Ply FBC Approved ASTM D4601, Type II HA at 20-401bs/'square Ply FBC Approved ASTM D2178, Type IV or A- (Base and Ply sheets, Asphalt -Applied) SBS-AA Cap Ply TriBuilt SBS Granular HA at 20-40 lbs/square (SBS, Asphalt -Applied) I SBS-TA Cap Ply TriBuilt SBS Granular Torch -Applied (SBS, Torch -Applied) SBS-SA Base Ply TrlBulk SA SBS Base - .. Self -Adhering Cap Ply TriBuilt SA SBS Cap (SBS, Self -Adhering) APP-TA Base Ply or Ply TriBuilt APP Smooth - Torch -Applied I Cap Ply. TriBuilt APP Smooth, TriBuilt APP Granular - (APP, Torch -Applied) APP-SA Cap Ply TriBuilt SA APP Cap Self -Adhering (APP, Self -Adhering) ! 16. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure(MDP)limitations. The lesser of the MDP listings below vs. those in Table 3A 'VAPOR BpRNIER OfTI0Na1STRUCiURAI.CodCRETEDECK; ApH�REd INSUTA'{ION PER TABLE 3A,, Optiod# Primer Vapor Barrier, Insulation Adhesive MDP (psF) - 7 e - YP Attach VB-1. ASTM D41 TriBuilt SA SBS Base „-Self-Adhering Inta-Stik or CR,20, 12-inch o.c. -60.0 VB-2. ASTM D41 TriBuilt SA SBS Cap. - - - Self -Adhering Insta-Stik, 12-Inch o.c. -75.0 VB-3. ASTM D41 -TriBuilt SA SBS Cap - Self -Adhering Millennium One Step Foamable Adhesive,12-inch o.c. -157.S VB-4.. .ASTM D41 TriBuilt SA SBS Cap Self -Adhering CR-20, 12-inch o.c. -270.0, - VB-5. -ASTM D41 . TriBuilt SA SBS Base Self -Adhering ' Mlllennium�One Step Foamable Adhesive, Millennium PG-1 Pump Grade Adhesive, OlyBond 500 or CR-20; 12-Inch o.c. -290.0' 17. Dens Deck shall be field -primed with PG100 prior to self adhering membrane application. Refer to tables herein for other priming requirements. - 18. "MDP" = Maximum Design Pressu reds the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. 0 Exterior Research and Design, LLC. d/b/a Trinity I ERD Evaluation Report A42970.30.12-R2 for FL16027-R2 Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVH2 EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 3 of 26