HomeMy WebLinkAboutNOAMIAMF� MICONTR L COUNTY ®��- PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miaaddade.eov/economy Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 2N^ t� Q 3 — SCANNED Irvine, CA 92618 BY FILE COPY St. Lucie e County This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Plantation Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA #15-0721.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Freddy Semino a NOA No.: 18-0829.02 Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Boral Plantation Concrete Roof Tile, as manufactured by Boral Roofing, LLC in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code for High Velocity Hurricane Zone. For use in locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Dimensions Test Product Applicant Specifications Description 1ti# °0rrgth:;§ TAS Fiat conercte roofhiedditk or th'W" atteqgd,natl oif, nuirfanonadhesiy plicahons Trim Pieces L = varies TAS 112 Accessory trim, concrete roof pieces for W = varies use at hips, rakes, ridges and valley Varying thickness terminations. Manufactured for each tile profile. 2.1. MANUFACTURING LOCATION 1. Okeechobee, FL 2.2 PRODUCTS MANUFACTURED By OTHERS Product Name ICP Adhesives Polyset® AH-160 TILE BOND' Roof Tile Adhesive DAP Foam Touch N Seal StormBondo 2 Roof Tile Adhesive Product Description Two component polyurethane foam adhesive. Single component polyurethane foam roof tile adhesive. Two component polyurethane foam adhesive. Manufacturer (With Current NOA) ICP Adhesives and Sealants, hrc. The Dow Chemical Company Dap Foam, Inc. NOA No.: 18-0829.02 Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 2 of 7 2.3 SUBMITTED EVIDENCE: Test A2ency American Test Lab of South Florida Redland Technologies The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, hic. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Farabaugh Engineering and Testing Inc. Farabaugh Engineering and Testing hie. Farabaugh Engineering and Testing Inc. PRI Construction Material Technologies 3. LIMITATIONS Test Identifier RT0624.05-14 7161-03 Appendix III 94-060B 94-084 7161-03 Appendix II Letter Dated Aug. 1, 1994 P0631-01 P0402 Project No. 307025 Test #MDC-76 Calculations Test Name/Reoort TAS 112 Static Uplift Testing PA 102 & PA 102(A) Static Uplift Testing PA 101 (Adhesive Set) (Mortar Set) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Mortar Set) Withdrawal Resistance Testing of screw vs, smooth shank nails Wind Driven Rain PA 100 Aerodynamic Multiplier Calculations 25-7183 25-7094 25-7496 Calculations 25-7584 25-7804b-8 25-7804-4 & 5 25-7848-6 Calculations Two Patty Adhesive Set System T295-11 TAS-108 T306-11 T279-11 DAPF-004-02-08 DAPF-004-02-09 DAPF-004-02-10 TAS-108 TAS-108 TAS 101 Static Uplift Resistance Adhesive Set Date 07/03/14 Dec. 1991 March, 1994 May 1994 Dec. 1991 Aug. 1994 July 1994 Sept. 1993 Oct. 1994 March 1999 April 1999 March 1995 February 1996 April 1996 December 1996 April 1999 10/05/11 10/04/11 09/23/11 07/26/18 07/26/18 07/26/18 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106, 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Miami -Dade Product Control office for review. MFDADE COUNTY NOA No.: 18-0829.02 ..., , Expiration Date:12/08120 Approval Date: 10/11/18 Page 3 of 7 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 4. INSTALLATION 4.1 Plantation Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (1 x w ) Tile Profile Weight-W (lbf) Length-1(ft) Width-w (ft) Plantation Tile 11.6 1.375 1.08 Table 2: Aerodynamic Multipliers - 1 (ft3) Tile Profile 2, (ft3) Batten Application % (ft3) Direct Deck Application Plantation Tile 0.267 0.289 Table 3: Restoring Moments due to Gravity - M (ft: Ibf) Tile Greater than Profile 2":12" 3":12" 4":12" 5":12" 611:12" 7":12" Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Deck Deck Deck Deck Deck Deck Plantation 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04 Tile MIAMI•DADE COUNTY NOA No.: 18-0829.02 Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 4 of 7 Table 4: Attachment. Resistance Expressed as a Moment - Mf (ft-lbf) For Nail -On Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (Min 15132" (Min. 19132" plywood) plywood) Plantation Tile 2-10d Ring Shank 30.9 38.1 17.2 Nails 1-10d Smooth or 7.3 9.8 4.9 Screw Shank Nail 2-10d Smooth or 14.0 18.8 7.4 Screw Shank Nails 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 1-10d Smooth or 24.3 24.3 24.2 Screw Shank Nail Field Clip) 1-10d Smooth or 19.0 19.0 22.1 Screw Shank Nail Eave Clip) 2-10d Smooth or 35.5 35.5 34.8 Screw Shank Nails Field Clip) 2-10d Smooth or 31.9 31.9 32.2 Screw Shank Nails Eave Clip) 2-10d Ring Shank 50.3 65.5 48.3 Nails' 1 Installation with a 4" the headlap and fasteners are located a minimum of 2%'from the head of tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) For Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Plantation Tile IAdhesive' 2 See manufactures component approval for installation requirements. 3 The Dow Chemical Co. TILE BONDw Roof Tile Adhesive weight per patty 13.9 grams. 31.3 4 ICP Adhesive and Sealants, Inc. ICP Adhesve PolysetO AH-160 Two -Component weight per patty 8 grams. 31.3 5 DAP Foam Touch N Seal StormBond® 2 Roof Tile Adhesive weight per paddy 8 grams. 45 NOA No.: 18-0829.02 MOAMFDADE COUNTY Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 5 of 7 Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) For Single Patty Adhesive Set S stems Tile Profile Tile Application Minimum Attachment Resistance Plantation Tile Adhesives 6 See manufactures component approval for installation requirements. 7 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset®AH-160.Two-Component weight perpatty45 grams. 118.9 8 ICP Adhesive and Sealants, Inc. ICP Adhesve Pol et®AH-160 Two -Component weight per patty 24 grams 40.4 9 DAP Foam Touch N Seal StormBonde 2 Roof Tile Adhesive weight per paddy45 grams. 73 10 DAP Foam Touch N Seal StormBondo 2 Roof Tile Adhesive weight per paddy 24 grams 48 Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance See specific mortar manufacturer's Notice of Acceptance. 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following statement: "Miami -Dade County Product Control Approved". Ka [ENTEURR BORAL PLANTATION ROOF TILE LABEL (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.: 18-0829.02 Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 6 of 7 � 31 1 •/1► BORAL PLANTATION FLAT CONCRETE TILE END OF THIS ACCEPTANCE NOA No.: 18-0829.02 MIAMI•DAD; counn Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 7 of 7 E] courlT? DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami Florida 33175-2474 T (786) 315-2590 F (786) 315= 599 NOTICE OF ACCEPTANCE (NOA) a'n'n'.miamidade.-m,/econnnry Tarco Specialty Products, Inc. e� One Information Way, Suite 225�(✓ �A^� l I �� �� Little Rock, AR 72202 SCABN�NED SCOPE: FILE'CupD St. Lucie County This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Tarco Roofing Membranes and Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA slumber preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at thejob site at the request of the Building Official. This NOA renews NOA No. 12-0420.02 and consists of pages I through 15. The submitted documentation was reviewed by Alex Tigera: MLAMI-DADE COUNTY NOA No.: 16-1116.09 •• , Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 1 of 15 N M ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Underlayment Material: Asphalt, SBS, Polyester SCOPE: This acceptance is for Tarco Roofing Membrane and Underlayments, for use with approved prepared roof assemblies where the applicable TAS/ASTM specific underlayment is specified and installed with prescribed approved adhesives, fasteners and fastener densities, as described in this Notice of Acceptance; designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone of the Florida Building Code. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Dimensions Test Specification Product Description 1F0-ie AS 6n1'ki� a ,_rSpeeiF c�.rt`�a"n'�'Fe It ,,may a1 i'FtrPn EasyLay 3' x 133' 4" rolls ASTM D226 Type If Sheet material comprising a polyester Manufacturing substrate coated with bituminous coating for Location #2 use as an underlayment in roofing applications. Designed as a shingle and metal roofing underlayment and for use in tile roofing assemblies when used with an approved TAS 103 tile underlayment cap sheet. Fiberglass Mineral 3' x 36'rolls ASTM D3909 Mineral surfaced glass fiber reinforced, Surfaced Roll asphalt coated roll roofing for hot mop or cold Roofing process application. Manufacturing Location #1 ASTM Organic Tile 3' x 36'rolls ASTM D6380 Asphalt saturated granular surfaced felt Underlayment Type 11 underlayment for hot mop application. Manufacturing Location #1 EasyMop SBS 3' x 36'rolls TAS 104 Granular surfaced polyester reinforced, SBS Manufacturing modified bituminous membrane for hot mop or Location #1 cold process application. Designed as a tile roofing underlayment. NOA No.: 16-1116.09 Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 2 of 15 Fast90 3' x 36' rolls TAS 103 Granular surfaced, asphalt -impregnated tLManufacturing ASTM D249 organic felt reinforced, bituminous sheet Location #1 ASTM D6380 material with a self-adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as a tile roofing underlayment. PS20011r 3' x 66'8" rolls TAS 103 Fabric surfaced, fiberglass reinforced, SBS Manufacturing ASTM D1970 modified bituminous sheet material with a Location #1 & #2 self-adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as a shingle, tile and metal roofing underlayment. PS2001ru 3' x 66'8" rolls ASTM D1970 Film surfaced, fiberglass reinforced, SBS Manufacturing modified bituminous sheet material with a Location #1 & #2 self-adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as a metal and shingle roofing underlayment. MS300 3x 66'8" rolls ASTM D1970 Fine granular surfaced, fiberglass reinforced, Manufacturing 3' x 33'4" rolls bituminous sheet material with a self-adhesive Location #1 & #2 bottom layer, for use as an underlayment in sloped roof assemblies. Designed as an ice and water shield, and a shingle roofing underlayment. SS400 3' x 66'8" rolls ASTM D1970 Smooth surfaced, fiberglass reinforced, Manufacturing 3' x 33'4" rolls bituminous sheet material with a self-adhesive Location #1 & #2 bottom layer, for use as an underlayment in sloped roof assemblies. Designed as an ice and water shield, and a shingle and metal roofing underlayment. NR500ar 3' x 66'8" rolls ASTM D 1970 Film surfaced. non -reinforced, bituminous Manufacturing sheet material with a self-adhesive bottom Location #3 layer, for use as an underlayment in sloped roof assemblies. Designed as an ice and water shield, and a shingle and metal roofing underlayment. NOA No.: 16-1116.09 MIAMFDADE COUNTY Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 3 of 15 MANUFACTURING LOCATION: 1. Greencastle, PA 2. Belton, TX 3. Coshocton, OH EVIDENCE SUBMITTED: Test AgencV Test Identifier Test Name/Report Date Atlantic & Carribean Roof ACRC06-013 TAS 103 06/14/06 Consulting, LLC PRI Asphalt Technologies TOT-003-02-01 ASTM D226 Type II 08/22/02 TOT-029-02-01 TAS 110, ASTM D249 & D 6380 07/05/05 TOT-030-02-01 TAS 110, ASTM D249 & D 6380 07/05/05 TOT-041-02-01 TAS 110, ASTM D226 Type II 05/24/06 TOT-042-02-01 ASTM D4798 & ASTM G 155 05/22/07 Trinity ERD T3580.10.06-2 TAS 103 10/26/06 T3580.10.06 TAS 103, ASTM D6380 10/12/06 T30160.08.09-RI ASTM D1970 10/12/10 T10550.07.08 ASTM D4798 &ASTM D1970 07/30/08 T32530.08.10 ASTM D1970 08/17/10 T33190.08.10 TAS 103 08/06/10 T43930.09.13-R2 TAS 104 09/11Aj T40790.04.12 ASTM D6380 04/06/12 T40780.04.12 ASTM D3909 04/06/12 T37610.07.11 TAS 114-D 07/29/11 IRT-Arcon IRT07-0006 ASTM D1970 07/11/07 IRT 07-0036 ASTM D1970 02/22/08 IRT08-0002 ASTM D1970 02/22/08 NOA No.: 16-1116.09 NIAMP rCOUNTY Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 4 of 15 M APPROVED ASSEMBLIES - 30# ASTM SPECIFICATION FELT: Deck Type: See Installation Requirements and General Limitations below. Deck Description: See Installation Requirements and General Limitations below. System E(1): See Installation Requirements and General Limitations below. INSTALLATION REQUIREMENTS - 30# ASTM SPECIFICATION FELT: 1. 30# ASTM Specification Felt shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with rooting practices and guidelines as outlined by the National Roofing Contractors Associations (NRCA) when installing 30# Felt. 3. During installation of 30# Felt, comply with Occupational Safety and Health Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to prevent accidents. 4. 30# ASTM Specification Felt shall be installed with a minimum 4" end lap in a shingle layer fashion and fastened as required by applicable system assemblies NOA or FBC 1518.2. GENERAL LIMITATIONS - 30# ASTM SPECIFICATION FELT: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. 30# ASTM Specification Felt may be used with any approved roof covering Notice of Acceptance listing ASTM D226 Type II felt as a component part of an assembly in the Notice of Acceptance. 4. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.: 16-1116.09 Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 5 of 15 M N APPROVED ASSEMBLIES - EASYLAY: Deck Type 1: Wood, Non -insulated Deck Description: 9/ ," or greater plywood or wood plank System E(2): Anchor sheet mechanically fastened to deck. Anchor Sheet: One or more plies of EasyLay underlayment, with a minimum 4" wide side lap and a minimum 8" wide end lap, mechanically fastened to deck. Fastening: Approved nails and tin caps 6" o.c. within lap and two equally spaced staggered rows 12" o.c. in the field (for Anchor/Base sheet).. Surfacing: Approved Roof Assemblies in lieu of FBC perscribed ASTM D 226 Type II felt INSTALLATION REQUIREMENTS - EASYLAY: I. EasyLay shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations (NRCA) when installing EasyLay. 3. During installation, comply with Occupational Safety and Health Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to prevent accidents. 4. EasyLay shall be acceptable for use with asphaltic shingles, wood shakes and shingles, quarry slate, tile and metal roofing assemblies. 5. Re -fasten any loose decking panels, and check for protruding nail heads prior to the application of EasyLay. 6. Place a full width piece of EasyLay, parallel to the eave (low) edge of the roof. 7. Unroll EasyLay 2 to 3 feet, with the lay lines facing up, and position the end of it to the edge of the eave and rake. 8. Install a few fasteners at the top, near the rake, and roll out the sheet to a manageable length. 9. Pull, straighten and align the sheet so that any wrinkles are eliminated and the sheet is even with the eave edge. 10. EasyLay shall be fastened with approved roofing nails and tin caps or approved cap nails, driven by hand or pneumatically, spaced 6" o.c. at all laps in the center of the seam area, and two staggered rows fastened 12" o.c. in the field of the sheet. 11. When installing nails, apply so that the head of the nail is flush with the EasyLay surface, without cutting into the EasyLay surface. 12. Fastening shall be done from the top to avoid walking or kneeling on unsecured sheet. 13. Continue on to the end of the substrate and fasten down. 14. Align the neat roll over the preceding sheet so as to form a minimum 4" overlap. 15. Then install the just placed sheet, per instructions above. 16. The bottom of the second coarse of EasyLay shall lay on top of the first course so that any water will flow over the top of EasyLay. 17. Apply subsequent sheets in the same manner, with 4" side laps and 6" end laps over the preceding sheets. 18. When the top course is reached, lap about 6" of EasyLay over the ridge. NOA No.: 16-1116.09 Expiration Date: O1125/22 Approval Date: O1112117 Page 6 of 15 M N 19. Install EasyLay a minimum of 6" up any vertical surfaces. 20. Stagger the end laps a minimum of 18" from the preceding course. 21. After installing EasyLay on the field of the roof, install drip edgeat the eaves (if used). 22. When applying EasyLay in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in each direction. Make sure there are no rips or large wrinkles in the EasyLay. 23. Before applying horizontal sections of EasyLay, install a vertical length of EasyLay down the center of the valley. 24. Several sections of EasyLay can be used, but be certain to overlap the higher sections several inches so any water will flow over the top of the sheet. 25. EasyLay underlayment in the valley areas must be covered with code prescribed metal or other approved valley lining material. 26, Apply a minimum 1/16" thick uniform layer of SBS trowel grade modified flashing cement to water proof areas of EasyLay where any cats or tears have occurred. Seams orjoints may require the application of an SBS trowel grade modified flashing cement. 27. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. GENERAL LIMITATIONS - EASYLAY: I . Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. EasyLay shall be applied to a clean and dry surface. 4. EasyLay shall not be torched or hot mopped to. Refer to manufacturer's published literature for additional information. 5. EasyLay shall not be used on slopes less than 2:12, unless the slope is acceptable to the weather resistant covering. In general, on slopes less than 4:12, a double layer of EasyLay is recommended. Double layer application is best achieved by using 19" side laps, making sure the side laps are 'shingled in' to shed water. 6. When installing EasyLay, the roof system must include proper ventilation. 7. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of EasyLay with specific prepared roofing products. EasyLay may be used with any approved roof covering Notice of Acceptance listing ASTM D 226 Type 11 felt as a component part of an assembly in the Notice of Acceptance. 8. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 9. EasyLay shall not be left exposed for longer than 30 days after application. 10. The manufacturer reserves the right to change product exposure period at any time; not to exceed the preceding maximum time limitations. NOA No.: 16-1116.09 Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 7 of 15 N N APPROVED ASSEMBLIES - FIBERGLASS MINERAL SURFACED ROLL ROOFING: Deck Type: See Installation Requirements and General Limitations below. Deck Description: See Installation Requirements and General Limitations below. System E(3): See Installation Requirements and General Limitations below. INSTALLATION REQUIREMENTS — FIBERGLASS MINERAL SURFACED ROLL ROOFING: 1. Fiberglass Mineral Surfaced Roll Roofing may be used with any approved roof covering Notice of Acceptance listing Fiberglass Mineral Surfaced Roll Roofing as a component part of an assembly in the Notice of Acceptance or wherever a ASTM D3909 roof membrane is specified and installed with prescribed approved asphalt, adhesives, fasteners and fastener densities per applicable FBC requirements. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations (NRCA) when installing Fiberglass Mineral Surfaced Roll Roofing. 3. During installation of Fiberglass Mineral Surfaced Roll Roofing, comply with Occupational Safety and Health Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to prevent accidents. GENERAL LIMITATIONS — FIBERGLASS MINERAL SURFACED ROLL ROOFING: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimaim deck requirements shall be in compliance with applicable building codes. 3. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 16-1116.09 Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 8 of 15 Lil N APPROVED ASSEMBLIES-ASTM ORGANIC TILE UNDERLAYMENT: Deck Type: See Installation Requirements and General Limitations below. Deck Description: See Installation Requirements and General Limitations below. System E(4): See Installation Requirements and General Limitations below. INSTALLATION REQUIREMENTS - ASTM ORGANIC TILE UNDERLAYMENT: I . ASTM Organic Tile Underlayment may be used with any approved roof covering Notice of Acceptance listing ASTM Organic Tile Underlayment as a component part of an assembly in the Notice of Acceptance or wherever a ASTM D6380 roof membrane is specified and installed with prescribed approved asphalt, adhesives, fasteners and fastener densities per applicable FBC requirements. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations (NRCA) when installing ASTM Organic Tile Underlayment. 3. During installation of ASTM Organic Tile Underlayment, comply with Occupational Safety and Health Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to prevent accidents. GENERAL LIMITATIONS-ASTM ORGANIC TILE UNDERLAYMENT: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building codes. 3. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 16-1116.09 Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 9 of 15 • M APPROVED ASSEMBLIES —EASYMOP SBS: Deck Type 1: Wood, Non -Insulated Deck Description: Minimum 19/32" plywood, wood plank System E(5): Anchor sheet mechanically fastened to deck, membrane adhered with hot asphalt or approved adhesive. Anchor/Base Sheet: One or more plies of ASTM D226 Type Il or ASTM D2626 with a minimum 4" wide side lap and a minimum 8" wide end lap, mechanically fastened to deck. Fastening: Approved nails and tin caps 6" o.c. within lap and two equally spaced staggered rows 12" o.c. in the field (for Anchor/Base sheet only). Membrane: EasyMop SBS applied to Anchor/Base Sheet with hot asphalt or with approved adhesive as specified in RAS 118, 1 19 or 120. (See #13 in Installation Requirements for back nailing) Surfacing: Approved Roof Assemblies as specified below. INSTALLATION REQUIREMENTS — EASYMOP SBS: 1. Tarco EasyMop SBS shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations (NRCA) when installing EasyMop SBS. 3. During installation, comply with Occupational Safety and Health Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to prevent accidents. 4. EasyMop SBS shall be an acceptable underlayment for mechanically fastened roof the and adhered roof tile applications. 5. Re -fasten any loose decking panels, and check for protruding nail heads prior to the application of EasyMop SBS. 6. EasyMop SBS shall not be adhered directly over any pre-existing roof membrane. 7. All approved substrates are to be clean, dry and free of any loose debris or moisture prior to the application of the EasyMop SBS. Refer to applicable building codes prior to installation to verify acceptable substrates. 8. Prime all metal collars, flashing, valleys, liner, drip edge and concrete deck substrate with ASTM D 41 primer. 9. Applicator may cut EasyMop SBS into sections for workability and allow to relax prior to application. 10. Place EasyMop SBS over metal drip edge in accordance with RAS 111. 11. Install the first course of EasyMop SBS parallel to the cave edge. 12. It is recommended that end laps be staggered a minimum of 18" from the preceding course. 13. EasyMop SBS shall be back nailed along the head lap. The nails shall be, 11 gauge V/4' approved ring shank type applied with a minimum of a IS/s" approved tin cap or approved capnail as required per the High Velocity Hurricane Zone (HVHZ) section of the FBC, at a minimum rate of 12" o.c. The head lap of the preceding layer of underlayment is to cover the area being back nailed. 14. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 15. Vertical strapping of EasyMop SBS membranes is acceptable. NOA No.: 16-1116.09 MIAMMADECOUMTY Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 10 of 15 • a GENERAL LIMITATIONS—EASYMOP SBS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. Tarco EasyMop SBS shall not be installed when any form of moisture such as water, dew, rain, etc. is present on the substrate. 4. Tarco EasyMop SBS are to be applied to a smooth, clean and dry surface, with the deck free from irregularities. 5. Ensure roof has positive drainage prior to installation of Tarco EasyMop SBS. 6. Tarco EasyMop SBS shall not be applied over a pre-existing roof membrane or system. 7. Care should be taken during the loading procedure to keep foot traffic to a minimum and avoid dropping the roof covering directly on the underlayment. 8. All tiles shall be staged ('two tiles perpendicular to slope, four tiles on top parallel to slope) as per manufacturer's requirements, not to exceed 6-high, to the standard maximum roof pitch of 5 :12 for flat tiles and 6 :12 for lugged tiles (See Tile Staging Method diagram below). At roof slopes greater than the above limitations, the use of loading battens or toe boards are required to load the roof tile. Tile Staging Method Front View - Staged Tiles (Slope — ) Side View - Staged Tiles (Slope L) 9. The manufacturer reserves the right to change the tile staging method at any time as well as the number of tiles stacked, not to exceed the preceding maximum number of tiles limitation. 10. Tarco EasyMop SBS shall not be left exposed as a temporary roof for longer than 180 days after application. The manufacturer reserves the right to change product exposure period at any time; not to exceed the preceding maximum time limitations. 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of Tarco underlayments with specific prepared roofing products. Tarco EasyMop SBS may be used with any approved roof coverings Notice of Acceptance listing Tarco EasyMop SBS or TAS 104 standard as a component part of an assembly in the Notice of Acceptance. If Tarco EasyMop SBS or the TAS 104 standards are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the product, wind uplift resistance, and fire testing results. 12. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of.the Florida Administrative Code. NOA No.: 16-1116.09 Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 11 of 15 • N APPROVED ASSEMBLIES —TARCO SELF -ADHERED UNDERLAYMENTS Deck Type 1: Wood, Non -Insulated Deck Description: Minimum 19/32" plywood, wood plank System E(6): Anchor sheet mechanically fastened to deck, membrane adhered. Anchor/Base Sheet: One or more plies of ASTM D226 Type 11, ASTM D2626, or EasyLay underlayment, with a minimum 4" wide side lap and a minimum 8" wide end lap, mechanically fastened to deck. Fastening: Approved nails and tin caps 6" o.c. within lap and two equally spaced staggered rows 12" o.c. in the field (for Anchor/Base sheet only). Membrane: All Tarco self -adhered membranes applied to approved Anchor/Base Sheet. (See #15 in Installation Requirements for back nailing) Surfacing: Approved Roof Assemblies as specified below. Deck Type 3: Concrete, Non -Insulated Deck Description: Structural concrete or concrete plank min. 2500 psi System F(1): Membrane self -adhered to concrete deck. Deck Preparation: The concrete deck shall be clean and dry and cured for a minimum of 28 days Anchor/Base Sheet: None. Fastening: Membrane shall be back nailed with approved concrete fasteners and 15/8" approved tin caps at a maximum spacing of 9" o.c. at the head laps and be covered by the preceding layer. No back nail fasteners or tin caps shall remain exposed). Membrane: Tarco PS200HT self -adhered membrane applied directly to concrete deck. (See Fastening above for back nailing) Surfacing: Approved Roof Assemblies as specified below. NOA No.: 16-1116.09 Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 12 of 15 C� M INSTALLATION REQUIREMENTS —TARCO SELF -ADHERED UNDERLAYMENTS: 1. Tarco self adhering underlayments shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations (NRCA) when installing Tarco self adhering underlayments. 3. During installation, comply with Occupational Safety and Health Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to prevent accidents. 4. Fast90 and PS200"r shall be acceptable underlayments for mechanically fastened roof tile and adhered roof tile applications. MS300 and SS400 shall be acceptable underlayments for asphaltic shingles, wood shakes and shingles, and slate or simulated slate roof assemblies. PS200"' and NR500"' shall be acceptable underlayments for asphaltic shingles, wood shakes, shingles, and metal roof panel assemblies. 5. Re -fasten any loose decking panels, and check for protruding nail heads prior to the application of the Tarco self adhering underlayments. 6. Tarco self adhering underlayments shall not be adhered directly over any pre-existing roof membrane. 7. All approved substrates are to be clean, dry and free of any loose debris or moisture prior to the application of the Tarco self adhering underlayments. Refer applicable building codes prior to installation to verify acceptable substrates. 8. Prime all metal collars, flashing, valleys, liner, drip edge and concrete deck substrate with ASTMD 41 primer, water based acrylic or water based polymer modified primer. 9. Contractor may cut the underlayments into sections for workability and allow to relax prior to application. 10. Place the underlayments over metal drip edge in accordance with RAS l 11. 11. Install the first course of underlayment parallel to the eave edge. 12. Apply the underlayment, working from the center of the material continuously to the ends of the sheet (half of the length of the sheet is the center); taking care to avoid wrinkles and ridges. 13. Remove the underlayments release film rapidly in a continuous fashion. Ensure the bottom adhesive side of the membrane does not adhere to its self. In the event this transpires,separate the two layers immediately. After some time, it may become impossible to do so without damaging the material. 14. It is recommended that end laps be staggered a minimum of 18" from the preceding course. 15. Underlayments are to be back nailed along the head lap. The nails shall be, 11 gauge 1'/4" approved ring shank type applied with a minimum of a V/s" approved tin cap or approved capnail as required per the High Velocity Hurricane Zone (HVHZ) section of the FBC, at a minimum rate of 9" o.c. The head lap of the preceding layer of underlayment is to cover the area being back nailed. 16. Roll or broom the entire membrane surface paying special attention to all overlap areas "side laps, end laps, T- joints" to ensure adhesion with acceptable substrates. A minimum of a 28 lb weighted roller may be used for steep slope applications. The use ofa soft bristled push broom is acceptable on steeper slopes. The above mentioned procedures are necessary in order to apply uniform pressure and allow for contact of the membranes. 17. Apply Ys" thick uniform layer of SBS trowel grade modified bitumen asphalt adhesive / flashing cement throughout the contact area of the 6" granule over granule and fabric over fabric end laps. Once the aforementioned procedure has been completed, the membrane must then be hand rolled in place in order to ensure contact of membrane and achieve a minimum of 1/80' asphaltic bleed out in designated area. 18. Tarco self adhering underlayments shall be applied to protrusions, slope changes, valleys, curbs, and other roof top penetrations before any other sections of the roof. 19. When applying underlayments in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in each direction. NOA No.: 16-1116.09 Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 13 of 15 w 20. For ridge applications, center the underlayment and roll from the center outward in both directions. 21. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 22. All protrusions or drains -shall be initially taped with a 6"piece of like kind membrane. "The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of like kind membrane shall be applied over the flashing detail. 23. Vertical strapping of Tarco self adhering membranes is acceptable. GENERAL LIMITATIONS — TARCO SELF -ADHERED UNDERLAYMENTS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. Tarco self adhering underlayments shall be applied only when material interface temperatures are 401 F and rising. 4. Tarco self -adhered underlayments shall not be installed when any form of moisture such as water, dew, rain, etc. is present on the substrate. 5. Tarco self -adhered underlayments are to be applied to a smooth, clean and dry surface, with the deck free from irregularities. 6. Ensure roof has positive drainage prior to installation of Tarco self -adhered underlayments. 7. Tarco self -adhered underlayments shall not be applied over a pre-existing roof membrane or system. 8. After installation of Tarco self -adhered membranes, wait a minimum of 48 hours before roof loading of tiles. 9. Care should be taken during the loading procedure to keep foot traffic to a minimum and avoid dropping the roof covering directly on the underlayment. 10 All tiles shall be staged (two tiles perpendicular to slope, four tiles on top parallel to slope) as per manufacturer's requirements, not to exceed 6-high, to the standard maximum roof pitch of 6 :12 for flat tiles and 6 :12 for lugged tiles (See Tile Staging Method diagram below). At roof slopes greater than the above limitations, the use of loading battens or toe boards are required to load the roof tile. Tile Staging Method Front View - Staged Tiles (Slope - ) Side View - Staged Tiles (Slope L) NOA No.: 16-1116.09 MIAMMADECOUNTY ,..., , Expiration Date: 01l25/22 -- Approval Date: 01/12/17 Page 14 of 15 N a 11. The manufacturer reserves the right to change the tile staging method at any time as well as the number of tiles stacked, not to exceed the preceding maximum number of tiles limitation. 12. EasyLay, PS200", MS300, SS400, and.NR500r'rshall not be left exposed as_a temporary roof for.longer than 30 days after application. PS200"' shall not be left exposed as a temporary roof for longer than 120 days after application. Fast90 shall not be left exposed as a temporary roof for longer than 180 days after application. The manufacturer reserves the right to change product exposure period at any time; not to exceed the preceding maximum time limitations. 13. NR500rr' is not recommended for extreme high temperature environments such as under copper or zinc metal roofing. 14. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of Tarco underlayments with specific prepared roofing products. Tarco self -adhered underlayments may be used with any approved roof coverings Notice of Acceptance listing Tarco self adhering underlayments or the ASTM standard which the self adhering underlayments meet as a component part of an assembly in the Notice of Acceptance. If Tarco self -adhered mnderlayments or the ASTM standards are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the product, wind uplift resistance, and fire testing results. 15. All products lined herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. MANUFACTURER'S CONSIDERATIONS: 1. When using Fast90 and PS200"r in tile roofing applications, use of loading battens or toe boards on roof slopes greater than 6:12 and higher is recommended. When using EasyMop SBS in tile roofing applications, use of loading battens or toe boards on roof slopes greater than 5:12 for Flat Tiles and 6:12 for Lugged Tiles and higher is recommended. 2. Code body requirements supersede manufacturer's recommendations and installation guidelines. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of these materials. LABELING: All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city, state and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY END OF THIS ACCEPTANCE NOA No.: 16-1116.09 Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 15 of 15 COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE Polyglass USA Inc. llll W. Newport Center Drive FILE COPY Deerfield Beach, FL 33442 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/economy SCANNED BY _�N` �t1� � IC[ 3 — p1 St. Lucie County SCOPE: C_ This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida. Building Code. DESCRIPTION: Polyglass Polystick Underlayments THESE PLANSANDALL.PROPOSED WORK ARE3UBJECTT� CORRECIIS H T LABELING: Each unit shall bear a permanent label with the manufacturer's n statement: "Miami -Dade County Product Control Approved", unless otherwiseWrYVININHAU APPUGABLECODES. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No.15-0410.04 and consists of pages 1 through 8. r� off pGNMEMS D FAMS CON SAB SDOFD The submitted documentation was reviewed by Freddy Semino.; QiiaEco v OA No.: 17-0614.22 MIAMI-DADE COUNTY ST. LUCIE COUNTY BUILDING DI ION Expiration Date: 09/13/21 REVIEWED FOR COMPLIANCE Approval Date: 07/06/17 REVIEIQ(E Y Page 1 of S DATE PLANS AND PER I MUST BE KEPT N OB SITE OR NO INSPECTION(S) WILL E 'IADE ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Underlayment Material: SBS , APP Self -Adhering Modified Bitumen PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description Polystick IR-Xe 65' x 3'3?4" ASTM D 1970 A fine granular/sand top surface self -adhering, APP Manufacturing Or 65' x 3' polymer modified, fiberglass reinforced, bituminous Location #1 & #2 60 mils thick sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield. Polystick Dual Pro 61' x 3'3'/8" TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a Location 42 metal roofing and roof tile underlayment. Polystick Tile Pro 61' x 3'3}/8" TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a metal Location #2 roofing and roof tile underlayment. Polystick TU Max 65'8" x 33-3/8" TAS 103 and A rubberized asphalt self -adhering, polyester reinforced Manufacturing 60 mils thick ASTM D 1970 waterproofing membrane. Designed as a a roof the Location #1 & #2 underlayment. Polystick TU P 32'10" x TV/s" TAS 103 and A rubberized asphalt waterproofing membrane, glass - Manufacturing 130 mils thick ASTM D 1970 fiber/polyester reinforced, with a granular surface Location #2 designed for use as a tile roof underlayment. Po 10 A bberized 1 e• k 1' 1 es2 z ( ' tng} 8 ' utl dHiek tD197{ x t°>:an x, a& �7ak u he e g° W� Polystick MTS 65'8" x 33 3/s" TAS 103 A homogeneous, rubberized asphalt waterproofing 60 mils thick membrane, glass fiber reinforced with polyolefinic film Manufacturing on the upper surface for use as an underlayment for metal Location #2 roofing, roof tile, slate tiles and shingle underlayment. Polystick MTS Plus 65'8" x 3'3 Ya' TAS 103 A homogeneous, rubberized asphalt "waterproofing Manufacturing 60 mils thick membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal Location #2 roofing, roof tile, slate tiles and shingle underlayment. Elastollex S6 G 32'10" x 3'3 %" TAS 103 and Polyester reinforced, SBS modified bitumen membrane Manufacturing ASTM D 6164 with a sanded back face and a granule top surface. For Location #2 use in roof tile underlayment systems. NOA No.: 17-0614.22 nwm•DADECOUNTY Expiration Date: 09/13/21 ` • • "- Approval Date: 07/06/17 Page 2 of 8 MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date Trinity ERD P10870.09.08-RI TAS 103 12/04/08 P10870.04.09 TAS 103/ASTM D4798 & G155 04/13/09 P33360.06.10 ASTM D1970 07/01/10 P33370.03.11 TAS 103 03/02/11 P33370.04.1 I ASTM D 1623 04/26/11 P36900.09.11 TAS 103/ASTM D4798 & G155 09/01/11 P37300.10.11 TAS 110/ASTM D4798 & D1970 10/19/11 P40390.08.12-2 ASTM D 1623 08/07/12 P37590.07.13-1 ASTM D6164 07/02/13 P45270.05.14 TAS 103, TAS 110 & ASTM D1623 05/12/14 P46520.10.14 ASTM D1623 10/03/14 P44360.10.14 TAS 103 & TAS 110 10/07/14 P43290.10.14 ASTM D 1970 & TAS 110 10/17/14 PLYG-SC10130.06.16-3 TAS 103 & TAS 110 06/27/16 PLYG-10130.06.16-1 ASTM D1970 & TAS 110 06/27/16 PRI Asphalt Technologies PUSA-035-02-01 TAS 103 09/29/06 PUSA-055-02-02 TAS 103 12/10/07 PUSA-089-02-01 TAS 103/ASTM D4798 & G155 07/06/09 Momentum Technologies, Inc. JX20H7A TAS 103/ASTM D4798 & G155 04/01/08 RX14E8A TAS 103/ASTM D4798 & G155 11/09/09 DX23D8B TAS 103/ASTM D4798 & G155 02/18/10 DX23138A TAS 103/ASTM D4798 & G155 02/18/10 LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 17-0614.22 Expiration Date: WARM Approval Date: 07/06/17 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or_wood.plank System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick NITS or Polystick MTS Plus, self -adhered. Surfacing: See General Limitations Below. Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(2): Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type 11 or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Elastollex S6 G, hot asphalt applied Surfacing: See General Limitations Below. Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o:c. at a minimum 4"head lap. (for base sheet only) Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Membrane: Polystick TU Plus, self -adhered. Surfacing: See General Limitations Below. NOA No.: 17-0614.22 MIAMMADECOUNTY Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 4 of 8 INSTALLATION REQUIREMENTS: 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and sweep the deck thoroughly to re move any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and Polystick MTS Plus may be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry slate roof assemblies. Polystick TU P may be used in all the previous assemblies listed except metal roofing. Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems. Polystick TU Max may be used in non-structural metal roofing and roof tile systems. Elastoflex S6 G may be used in roof tile systems only. 3. Deck requirements shall be in compliance with applicable building code. 4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations (Days) MTS IR-Xe Elastotlex S6 G TU Plus TU P Tile Pro Dual Pro TU Max MTS Plus Winter Haven, FL 180 90 180 180 180 180 180 180 180 Hazelton,PA N/A 90 N/A 180 N/A N/A N/A 180 N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and NOA No.: 17-0614.22 MAMMADE COUNTY Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 5 of 8 Rule 61 G20-3 of the Florida Administrative Code. S. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive set and mechanically fastened roof tile applications. Polystick Dual Pro is limited to mechanically fastened roof tile applications. Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in Section 9. Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximum roof slope shall be as follows: (See Table Below) Tile Polystick Elastoflex Polystick TU Plus, Polystick Polystick System (E3) Profile MTS S6 G TU P, Tile Pro, TU Max MTS Plus MTS Plus with Dual Pro TU Plus Flat Tile Prohibited 4:12 6:12 6:12 5:12 6:12 without battens Profiled Prohibited 4:12 6:12 6:12 4:12 6:12 Tile without battens The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. When battens are required, they shall be utilized during loading and installation of tiles. 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure — two tiles laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles — for all underlayments except Polystick MTS which shall be loaded onto battens. POLWTICKTU PWs NOA No.: 17-0614.22 MLAMMADECOUNTY Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 6 of 8 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick NITS Plus or Elastoflex S6 G may be used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance. If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 1 I gauge ring shank type, applied with a minimum I V metal disk as required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back -nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for pitch/slopes of 7/12" or greater. It is suggested that on pitch/slopes in excess of 6 %<"/12", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. NOA No.: 17-0614.22 MIAMI•DADECOUNTY Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 7 of 8 10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 Ibs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished upon request by our Technical Services Department by calling I (800) 894-4563. 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 17-0614.22 Expiration Date: 09/1321 Approval Date: 07/06/17 Page 8 of 8