NOTICE OF ACCEPTANCE (NOA) www.miaaddade.eov/economy
Boral Roofing, LLC
7575 Irvine Center Drive, Suite 100 2N^ t� Q 3 — SCANNED
Irvine, CA 92618 BY
FILE COPY St. Lucie e County
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Plantation Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA #15-0721.04 and consists of pages 1 through 7.
The submitted documentation was reviewed by Freddy Semino a
NOA No.: 18-0829.02
Expiration Date: 12/08/20
Approval Date: 10/11/18
Page 1 of 7
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub -Category: Roofing Tiles
Material: Concrete
1. SCOPE
This approves a roofing system using Boral Plantation Concrete Roof Tile, as manufactured by Boral Roofing, LLC
in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida
Building Code for High Velocity Hurricane Zone. For use in locations where the pressure requirements, as determined
by applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS
127 using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based
system.
2. PRODUCT DESCRIPTION
Manufactured by Dimensions Test Product
Applicant Specifications Description
1ti# °0rrgth:;§ TAS Fiat conercte roofhiedditk or
th'W" atteqgd,natl oif, nuirfanonadhesiy
plicahons
Trim Pieces L = varies TAS 112 Accessory trim, concrete roof pieces for
W = varies use at hips, rakes, ridges and valley
Varying thickness terminations. Manufactured for each tile
profile.
2.1. MANUFACTURING LOCATION
1. Okeechobee, FL
2.2 PRODUCTS MANUFACTURED By OTHERS
Product Name
ICP Adhesives Polyset® AH-160
TILE BOND' Roof Tile Adhesive
DAP Foam Touch N Seal
StormBondo 2 Roof Tile Adhesive
Product Description
Two component polyurethane
foam adhesive.
Single component polyurethane
foam roof tile adhesive.
Two component polyurethane
foam adhesive.
Manufacturer
(With Current NOA)
ICP Adhesives and Sealants, hrc.
The Dow Chemical Company
Dap Foam, Inc.
NOA No.: 18-0829.02
Expiration Date: 12/08/20
Approval Date: 10/11/18
Page 2 of 7
2.3 SUBMITTED EVIDENCE:
Test A2ency
American Test Lab of South
Florida
Redland Technologies
The Center for Applied
Engineering, Inc.
Redland Technologies
Redland Technologies
Redland Technologies
Redland Technologies
The Center for Applied
Engineering, hic.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Farabaugh Engineering and
Testing Inc.
Farabaugh Engineering and
Testing hie.
Farabaugh Engineering and
Testing Inc.
PRI Construction Material
Technologies
3. LIMITATIONS
Test Identifier
RT0624.05-14
7161-03
Appendix III
94-060B
94-084
7161-03
Appendix II
Letter Dated Aug. 1, 1994
P0631-01
P0402
Project No. 307025
Test #MDC-76
Calculations
Test Name/Reoort
TAS 112
Static Uplift Testing
PA 102 & PA 102(A)
Static Uplift Testing
PA 101 (Adhesive Set)
(Mortar Set)
Wind Tunnel Testing
PA 108 (Nail -On)
Wind Tunnel Testing
PA 108 (Nail -On)
Wind Tunnel Testing
PA 108 (Mortar Set)
Withdrawal Resistance Testing of
screw vs, smooth shank nails
Wind Driven Rain
PA 100
Aerodynamic Multiplier
Calculations
25-7183
25-7094
25-7496
Calculations
25-7584
25-7804b-8
25-7804-4 & 5
25-7848-6
Calculations
Two Patty Adhesive Set System
T295-11
TAS-108
T306-11
T279-11
DAPF-004-02-08
DAPF-004-02-09
DAPF-004-02-10
TAS-108
TAS-108
TAS 101
Static Uplift Resistance
Adhesive Set
Date
07/03/14
Dec. 1991
March, 1994
May 1994
Dec. 1991
Aug. 1994
July 1994
Sept. 1993
Oct. 1994
March 1999
April 1999
March 1995
February 1996
April 1996
December 1996
April 1999
10/05/11
10/04/11
09/23/11
07/26/18
07/26/18
07/26/18
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106,
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Miami -Dade Product
Control office for review.
MFDADE COUNTY NOA No.: 18-0829.02
..., , Expiration Date:12/08120
Approval Date: 10/11/18
Page 3 of 7
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 61 G20-3 of the Florida Administrative Code.
4. INSTALLATION
4.1 Plantation Roof Tile and its components shall be installed in strict compliance with Roofing Application
Standard RAS 118, RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (1 x w )
Tile Profile
Weight-W (lbf)
Length-1(ft)
Width-w (ft)
Plantation Tile
11.6
1.375
1.08
Table 2: Aerodynamic Multipliers - 1 (ft3)
Tile
Profile
2, (ft3)
Batten Application
% (ft3)
Direct Deck Application
Plantation Tile
0.267
0.289
Table 3: Restoring Moments due to Gravity - M (ft: Ibf)
Tile
Greater than
Profile
2":12"
3":12"
4":12"
5":12"
611:12"
7":12"
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Deck
Deck
Deck
Deck
Deck
Deck
Plantation
7.22
7.91
6.85
7.79
6.75
7.67
6.61
7.52
6.44
7.32
6.26
7.04
Tile
MIAMI•DADE COUNTY
NOA No.: 18-0829.02
Expiration Date: 12/08/20
Approval Date: 10/11/18
Page 4 of 7
Table 4: Attachment. Resistance Expressed as a Moment - Mf (ft-lbf)
For Nail -On Systems
Tile
Fastener Type
Direct Deck
Direct Deck
Battens
Profile
(Min 15132"
(Min. 19132"
plywood)
plywood)
Plantation Tile
2-10d Ring Shank
30.9
38.1
17.2
Nails
1-10d Smooth or
7.3
9.8
4.9
Screw Shank Nail
2-10d Smooth or
14.0
18.8
7.4
Screw Shank Nails
1 #8 Screw
30.8
30.8
18.2
2 #8 Screw
51.7
51.7
24.4
1-10d Smooth or
24.3
24.3
24.2
Screw Shank Nail
Field Clip)
1-10d Smooth or
19.0
19.0
22.1
Screw Shank Nail
Eave Clip)
2-10d Smooth or
35.5
35.5
34.8
Screw Shank Nails
Field Clip)
2-10d Smooth or
31.9
31.9
32.2
Screw Shank Nails
Eave Clip)
2-10d Ring Shank
50.3
65.5
48.3
Nails'
1 Installation with a 4" the headlap and fasteners are located a minimum of 2%'from the head of tile.
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf)
For Two Patty Adhesive Set Systems
Tile Profile
Tile Application
Minimum Attachment
Resistance
Plantation Tile
IAdhesive'
2 See manufactures component approval for installation requirements.
3 The Dow Chemical Co. TILE BONDw Roof Tile Adhesive weight per patty 13.9 grams. 31.3
4 ICP Adhesive and Sealants, Inc. ICP Adhesve PolysetO AH-160 Two -Component weight per patty 8 grams. 31.3
5 DAP Foam Touch N Seal StormBond® 2 Roof Tile Adhesive weight per paddy 8 grams. 45
NOA No.: 18-0829.02
MOAMFDADE COUNTY Expiration Date: 12/08/20
Approval Date: 10/11/18
Page 5 of 7
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
For Single Patty Adhesive Set S stems
Tile Profile
Tile Application
Minimum Attachment Resistance
Plantation Tile
Adhesives
6
See manufactures component approval for installation requirements.
7
ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset®AH-160.Two-Component weight perpatty45 grams.
118.9
8
ICP Adhesive and Sealants, Inc. ICP Adhesve Pol et®AH-160 Two -Component weight per patty 24 grams
40.4
9
DAP Foam Touch N Seal StormBonde 2 Roof Tile Adhesive weight per paddy45 grams.
73
10
DAP Foam Touch N Seal StormBondo 2 Roof Tile Adhesive weight per paddy 24 grams
48
Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Mortar Set Systems
Tile Profile Tile Application Attachment
Resistance
See specific mortar manufacturer's Notice of Acceptance.
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following
statement: "Miami -Dade County Product Control Approved".
Ka
[ENTEURR
BORAL PLANTATION ROOF TILE LABEL (LOCATED ON UNDERSIDE OF TILE)
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to properly
evaluate the installation of this system.
NOA No.: 18-0829.02
Expiration Date: 12/08/20
Approval Date: 10/11/18
Page 6 of 7
� 31 1 •/1►
BORAL PLANTATION FLAT CONCRETE TILE
END OF THIS ACCEPTANCE
NOA No.: 18-0829.02
MIAMI•DAD; counn Expiration Date: 12/08/20
Approval Date: 10/11/18
Page 7 of 7
E]
courlT?
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami Florida 33175-2474
T (786) 315-2590 F (786) 315= 599
NOTICE OF ACCEPTANCE (NOA) a'n'n'.miamidade.-m,/econnnry
Tarco Specialty Products, Inc. e�
One Information Way, Suite 225�(✓ �A^� l I �� ��
Little Rock, AR 72202 SCABN�NED
SCOPE: FILE'CupD St. Lucie County
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Tarco Roofing Membranes and Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA slumber preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at thejob site at the request of the Building Official.
This NOA renews NOA No. 12-0420.02 and consists of pages I through 15.
The submitted documentation was reviewed by Alex Tigera:
MLAMI-DADE COUNTY NOA No.: 16-1116.09
•• , Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 1 of 15
N
M
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: Asphalt, SBS, Polyester
SCOPE:
This acceptance is for Tarco Roofing Membrane and Underlayments, for use with approved prepared roof
assemblies where the applicable TAS/ASTM specific underlayment is specified and installed with prescribed approved
adhesives, fasteners and fastener densities, as described in this Notice of Acceptance; designed to comply with the
Florida Building Code, including the High Velocity Hurricane Zone of the Florida Building Code.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product Dimensions Test Specification Product Description
1F0-ie AS 6n1'ki� a
,_rSpeeiF c�.rt`�a"n'�'Fe It
,,may a1 i'FtrPn
EasyLay
3' x 133' 4" rolls ASTM D226 Type If
Sheet material comprising a polyester
Manufacturing
substrate coated with bituminous coating for
Location #2
use as an underlayment in roofing
applications. Designed as a shingle and metal
roofing underlayment and for use in tile
roofing assemblies when used with an
approved TAS 103 tile underlayment cap
sheet.
Fiberglass Mineral
3' x 36'rolls ASTM D3909
Mineral surfaced glass fiber reinforced,
Surfaced Roll
asphalt coated roll roofing for hot mop or cold
Roofing
process application.
Manufacturing
Location #1
ASTM Organic Tile
3' x 36'rolls ASTM D6380
Asphalt saturated granular surfaced felt
Underlayment
Type 11
underlayment for hot mop application.
Manufacturing
Location #1
EasyMop SBS
3' x 36'rolls TAS 104
Granular surfaced polyester reinforced, SBS
Manufacturing
modified bituminous membrane for hot mop or
Location #1
cold process application. Designed as a tile
roofing underlayment.
NOA No.: 16-1116.09
Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 2 of 15
Fast90 3' x 36' rolls TAS 103 Granular surfaced, asphalt -impregnated
tLManufacturing ASTM D249 organic felt reinforced, bituminous sheet
Location #1 ASTM D6380 material with a self-adhesive bottom layer, for
use as an underlayment in sloped roof
assemblies. Designed as a tile roofing
underlayment.
PS20011r 3' x 66'8" rolls TAS 103 Fabric surfaced, fiberglass reinforced, SBS
Manufacturing ASTM D1970 modified bituminous sheet material with a
Location #1 & #2 self-adhesive bottom layer, for use as an
underlayment in sloped roof assemblies.
Designed as a shingle, tile and metal roofing
underlayment.
PS2001ru 3' x 66'8" rolls ASTM D1970 Film surfaced, fiberglass reinforced, SBS
Manufacturing modified bituminous sheet material with a
Location #1 & #2 self-adhesive bottom layer, for use as an
underlayment in sloped roof assemblies.
Designed as a metal and shingle roofing
underlayment.
MS300 3x 66'8" rolls ASTM D1970 Fine granular surfaced, fiberglass reinforced,
Manufacturing 3' x 33'4" rolls bituminous sheet material with a self-adhesive
Location #1 & #2 bottom layer, for use as an underlayment in
sloped roof assemblies. Designed as an ice
and water shield, and a shingle roofing
underlayment.
SS400 3' x 66'8" rolls
ASTM D1970 Smooth surfaced, fiberglass reinforced,
Manufacturing 3' x 33'4" rolls
bituminous sheet material with a self-adhesive
Location #1 & #2
bottom layer, for use as an underlayment in
sloped roof assemblies. Designed as an ice
and water shield, and a shingle and metal
roofing underlayment.
NR500ar 3' x 66'8" rolls
ASTM D 1970 Film surfaced. non -reinforced, bituminous
Manufacturing
sheet material with a self-adhesive bottom
Location #3
layer, for use as an underlayment in sloped
roof assemblies. Designed as an ice and water
shield, and a shingle and metal roofing
underlayment.
NOA No.: 16-1116.09
MIAMFDADE COUNTY Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 3 of 15
MANUFACTURING LOCATION:
1. Greencastle, PA
2. Belton, TX
3. Coshocton, OH
EVIDENCE SUBMITTED:
Test AgencV Test Identifier Test Name/Report Date
Atlantic & Carribean Roof ACRC06-013 TAS 103 06/14/06
Consulting, LLC
PRI Asphalt Technologies
TOT-003-02-01
ASTM D226 Type II
08/22/02
TOT-029-02-01
TAS 110, ASTM D249 & D 6380
07/05/05
TOT-030-02-01
TAS 110, ASTM D249 & D 6380
07/05/05
TOT-041-02-01
TAS 110, ASTM D226 Type II
05/24/06
TOT-042-02-01
ASTM D4798 & ASTM G 155
05/22/07
Trinity ERD
T3580.10.06-2
TAS 103
10/26/06
T3580.10.06
TAS 103, ASTM D6380
10/12/06
T30160.08.09-RI
ASTM D1970
10/12/10
T10550.07.08
ASTM D4798 &ASTM D1970
07/30/08
T32530.08.10
ASTM D1970
08/17/10
T33190.08.10
TAS 103
08/06/10
T43930.09.13-R2
TAS 104
09/11Aj
T40790.04.12
ASTM D6380
04/06/12
T40780.04.12
ASTM D3909
04/06/12
T37610.07.11
TAS 114-D
07/29/11
IRT-Arcon
IRT07-0006
ASTM D1970
07/11/07
IRT 07-0036
ASTM D1970
02/22/08
IRT08-0002
ASTM D1970
02/22/08
NOA No.: 16-1116.09
NIAMP rCOUNTY Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 4 of 15
M
APPROVED ASSEMBLIES - 30# ASTM SPECIFICATION FELT:
Deck Type: See Installation Requirements and General Limitations below.
Deck Description: See Installation Requirements and General Limitations below.
System E(1): See Installation Requirements and General Limitations below.
INSTALLATION REQUIREMENTS - 30# ASTM SPECIFICATION FELT:
1. 30# ASTM Specification Felt shall be installed in strict compliance with applicable Building Codes.
2. Observe and comply with rooting practices and guidelines as outlined by the National Roofing Contractors
Associations (NRCA) when installing 30# Felt.
3. During installation of 30# Felt, comply with Occupational Safety and Health Administration (OSHA) safety
standards; use common sense measures and adequate safety precautions to prevent accidents.
4. 30# ASTM Specification Felt shall be installed with a minimum 4" end lap in a shingle layer fashion and
fastened as required by applicable system assemblies NOA or FBC 1518.2.
GENERAL LIMITATIONS - 30# ASTM SPECIFICATION FELT:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.
3. 30# ASTM Specification Felt may be used with any approved roof covering Notice of Acceptance listing
ASTM D226 Type II felt as a component part of an assembly in the Notice of Acceptance.
4. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
NOA No.: 16-1116.09
Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 5 of 15
M N
APPROVED ASSEMBLIES - EASYLAY:
Deck Type 1: Wood, Non -insulated
Deck Description: 9/ ," or greater plywood or wood plank
System E(2): Anchor sheet mechanically fastened to deck.
Anchor Sheet: One or more plies of EasyLay underlayment, with a minimum 4" wide side lap and a minimum
8" wide end lap, mechanically fastened to deck.
Fastening: Approved nails and tin caps 6" o.c. within lap and two equally spaced staggered rows 12" o.c.
in the field (for Anchor/Base sheet)..
Surfacing: Approved Roof Assemblies in lieu of FBC perscribed ASTM D 226 Type II felt
INSTALLATION REQUIREMENTS - EASYLAY:
I. EasyLay shall be installed in strict compliance with applicable Building Codes.
2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors
Associations (NRCA) when installing EasyLay.
3. During installation, comply with Occupational Safety and Health Administration (OSHA) safety standards; use
common sense measures and adequate safety precautions to prevent accidents.
4. EasyLay shall be acceptable for use with asphaltic shingles, wood shakes and shingles, quarry slate, tile and
metal roofing assemblies.
5. Re -fasten any loose decking panels, and check for protruding nail heads prior to the application of EasyLay.
6. Place a full width piece of EasyLay, parallel to the eave (low) edge of the roof.
7. Unroll EasyLay 2 to 3 feet, with the lay lines facing up, and position the end of it to the edge of the eave and
rake.
8. Install a few fasteners at the top, near the rake, and roll out the sheet to a manageable length.
9. Pull, straighten and align the sheet so that any wrinkles are eliminated and the sheet is even with the eave edge.
10. EasyLay shall be fastened with approved roofing nails and tin caps or approved cap nails, driven by hand or
pneumatically, spaced 6" o.c. at all laps in the center of the seam area, and two staggered rows fastened 12"
o.c. in the field of the sheet.
11. When installing nails, apply so that the head of the nail is flush with the EasyLay surface, without cutting into
the EasyLay surface.
12. Fastening shall be done from the top to avoid walking or kneeling on unsecured sheet.
13. Continue on to the end of the substrate and fasten down.
14. Align the neat roll over the preceding sheet so as to form a minimum 4" overlap.
15. Then install the just placed sheet, per instructions above.
16. The bottom of the second coarse of EasyLay shall lay on top of the first course so that any water will flow over
the top of EasyLay.
17. Apply subsequent sheets in the same manner, with 4" side laps and 6" end laps over the preceding sheets.
18. When the top course is reached, lap about 6" of EasyLay over the ridge.
NOA No.: 16-1116.09
Expiration Date: O1125/22
Approval Date: O1112117
Page 6 of 15
M
N
19. Install EasyLay a minimum of 6" up any vertical surfaces.
20. Stagger the end laps a minimum of 18" from the preceding course.
21. After installing EasyLay on the field of the roof, install drip edgeat the eaves (if used).
22. When applying EasyLay in the valley, start at the low point and work to the high point, rolling the membrane
from the center outward in each direction. Make sure there are no rips or large wrinkles in the EasyLay.
23. Before applying horizontal sections of EasyLay, install a vertical length of EasyLay down the center of the
valley.
24. Several sections of EasyLay can be used, but be certain to overlap the higher sections several inches so any
water will flow over the top of the sheet.
25. EasyLay underlayment in the valley areas must be covered with code prescribed metal or other approved valley
lining material.
26, Apply a minimum 1/16" thick uniform layer of SBS trowel grade modified flashing cement to water proof
areas of EasyLay where any cats or tears have occurred. Seams orjoints may require the application of an SBS
trowel grade modified flashing cement.
27. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current
Product Control Notice of Acceptance and applicable Building Code.
GENERAL LIMITATIONS - EASYLAY:
I . Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.
3. EasyLay shall be applied to a clean and dry surface.
4. EasyLay shall not be torched or hot mopped to. Refer to manufacturer's published literature for additional
information.
5. EasyLay shall not be used on slopes less than 2:12, unless the slope is acceptable to the weather resistant
covering. In general, on slopes less than 4:12, a double layer of EasyLay is recommended.
Double layer application is best achieved by using 19" side laps, making sure the side laps are 'shingled in' to
shed water.
6. When installing EasyLay, the roof system must include proper ventilation.
7. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of EasyLay with
specific prepared roofing products. EasyLay may be used with any approved roof covering Notice of
Acceptance listing ASTM D 226 Type 11 felt as a component part of an assembly in the Notice of Acceptance.
8. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
9. EasyLay shall not be left exposed for longer than 30 days after application.
10. The manufacturer reserves the right to change product exposure period at any time; not to exceed the preceding
maximum time limitations.
NOA No.: 16-1116.09
Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 7 of 15
N
N
APPROVED ASSEMBLIES - FIBERGLASS MINERAL SURFACED ROLL ROOFING:
Deck Type: See Installation Requirements and General Limitations below.
Deck Description: See Installation Requirements and General Limitations below.
System E(3): See Installation Requirements and General Limitations below.
INSTALLATION REQUIREMENTS — FIBERGLASS MINERAL SURFACED ROLL ROOFING:
1. Fiberglass Mineral Surfaced Roll Roofing may be used with any approved roof covering Notice of Acceptance
listing Fiberglass Mineral Surfaced Roll Roofing as a component part of an assembly in the Notice of
Acceptance or wherever a ASTM D3909 roof membrane is specified and installed with prescribed approved
asphalt, adhesives, fasteners and fastener densities per applicable FBC requirements.
2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors
Associations (NRCA) when installing Fiberglass Mineral Surfaced Roll Roofing.
3. During installation of Fiberglass Mineral Surfaced Roll Roofing, comply with Occupational Safety and Health
Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to
prevent accidents.
GENERAL LIMITATIONS — FIBERGLASS MINERAL SURFACED ROLL ROOFING:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. This acceptance is for prepared roofing applications. Minimaim deck requirements shall be in compliance with
applicable building codes.
3. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 16-1116.09
Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 8 of 15
Lil
N
APPROVED ASSEMBLIES-ASTM ORGANIC TILE UNDERLAYMENT:
Deck Type: See Installation Requirements and General Limitations below.
Deck Description: See Installation Requirements and General Limitations below.
System E(4): See Installation Requirements and General Limitations below.
INSTALLATION REQUIREMENTS - ASTM ORGANIC TILE UNDERLAYMENT:
I . ASTM Organic Tile Underlayment may be used with any approved roof covering Notice of Acceptance listing
ASTM Organic Tile Underlayment as a component part of an assembly in the Notice of Acceptance or wherever
a ASTM D6380 roof membrane is specified and installed with prescribed approved asphalt, adhesives, fasteners
and fastener densities per applicable FBC requirements.
2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors
Associations (NRCA) when installing ASTM Organic Tile Underlayment.
3. During installation of ASTM Organic Tile Underlayment, comply with Occupational Safety and Health
Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to
prevent accidents.
GENERAL LIMITATIONS-ASTM ORGANIC TILE UNDERLAYMENT:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building codes.
3. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 16-1116.09
Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 9 of 15
•
M
APPROVED ASSEMBLIES —EASYMOP SBS:
Deck Type 1: Wood, Non -Insulated
Deck Description: Minimum 19/32" plywood, wood plank
System E(5): Anchor sheet mechanically fastened to deck, membrane adhered with hot asphalt or
approved adhesive.
Anchor/Base Sheet: One or more plies of ASTM D226 Type Il or ASTM D2626 with a minimum 4" wide side
lap and a minimum 8" wide end lap, mechanically fastened to deck.
Fastening: Approved nails and tin caps 6" o.c. within lap and two equally spaced staggered rows 12"
o.c. in the field (for Anchor/Base sheet only).
Membrane: EasyMop SBS applied to Anchor/Base Sheet with hot asphalt or with approved adhesive as
specified in RAS 118, 1 19 or 120.
(See #13 in Installation Requirements for back nailing)
Surfacing: Approved Roof Assemblies as specified below.
INSTALLATION REQUIREMENTS — EASYMOP SBS:
1. Tarco EasyMop SBS shall be installed in strict compliance with applicable Building Codes.
2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors
Associations (NRCA) when installing EasyMop SBS.
3. During installation, comply with Occupational Safety and Health Administration (OSHA) safety standards; use
common sense measures and adequate safety precautions to prevent accidents.
4. EasyMop SBS shall be an acceptable underlayment for mechanically fastened roof the and adhered roof tile
applications.
5. Re -fasten any loose decking panels, and check for protruding nail heads prior to the application of EasyMop
SBS.
6. EasyMop SBS shall not be adhered directly over any pre-existing roof membrane.
7. All approved substrates are to be clean, dry and free of any loose debris or moisture prior to the application of
the EasyMop SBS. Refer to applicable building codes prior to installation to verify acceptable substrates.
8. Prime all metal collars, flashing, valleys, liner, drip edge and concrete deck substrate with ASTM D 41 primer.
9. Applicator may cut EasyMop SBS into sections for workability and allow to relax prior to application.
10. Place EasyMop SBS over metal drip edge in accordance with RAS 111.
11. Install the first course of EasyMop SBS parallel to the cave edge.
12. It is recommended that end laps be staggered a minimum of 18" from the preceding course.
13. EasyMop SBS shall be back nailed along the head lap. The nails shall be, 11 gauge V/4' approved ring shank
type applied with a minimum of a IS/s" approved tin cap or approved capnail as required per the High Velocity
Hurricane Zone (HVHZ) section of the FBC, at a minimum rate of 12" o.c. The head lap of the preceding
layer of underlayment is to cover the area being back nailed.
14. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product
Control Notice of Acceptance and applicable Building Code.
15. Vertical strapping of EasyMop SBS membranes is acceptable.
NOA No.: 16-1116.09
MIAMMADECOUMTY Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 10 of 15
• a
GENERAL LIMITATIONS—EASYMOP SBS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.
3. Tarco EasyMop SBS shall not be installed when any form of moisture such as water, dew, rain, etc. is present
on the substrate.
4. Tarco EasyMop SBS are to be applied to a smooth, clean and dry surface, with the deck free from irregularities.
5. Ensure roof has positive drainage prior to installation of Tarco EasyMop SBS.
6. Tarco EasyMop SBS shall not be applied over a pre-existing roof membrane or system.
7. Care should be taken during the loading procedure to keep foot traffic to a minimum and avoid dropping the
roof covering directly on the underlayment.
8. All tiles shall be staged ('two tiles perpendicular to slope, four tiles on top parallel to slope) as per
manufacturer's requirements, not to exceed 6-high, to the standard maximum roof pitch of 5 :12 for flat tiles
and 6 :12 for lugged tiles (See Tile Staging Method diagram below).
At roof slopes greater than the above limitations, the use of loading battens or toe boards are required to load the
roof tile.
Tile Staging Method
Front View - Staged Tiles (Slope — )
Side View - Staged Tiles (Slope L)
9. The manufacturer reserves the right to change the tile staging method at any time as well as the number of tiles
stacked, not to exceed the preceding maximum number of tiles limitation.
10. Tarco EasyMop SBS shall not be left exposed as a temporary roof for longer than 180 days after application.
The manufacturer reserves the right to change product exposure period at any time; not to exceed the preceding
maximum time limitations.
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of Tarco
underlayments with specific prepared roofing products. Tarco EasyMop SBS may be used with any approved
roof coverings Notice of Acceptance listing Tarco EasyMop SBS or TAS 104 standard as a component part of
an assembly in the Notice of Acceptance.
If Tarco EasyMop SBS or the TAS 104 standards are not listed, a request may be made to the Authority Having
Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that
appropriate documentation is provided to detail compatibility of the product, wind uplift resistance, and fire
testing results.
12. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of.the Florida Administrative Code.
NOA No.: 16-1116.09
Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 11 of 15
•
N
APPROVED ASSEMBLIES —TARCO SELF -ADHERED UNDERLAYMENTS
Deck Type 1: Wood, Non -Insulated
Deck Description: Minimum 19/32" plywood, wood plank
System E(6): Anchor sheet mechanically fastened to deck, membrane adhered.
Anchor/Base Sheet: One or more plies of ASTM D226 Type 11, ASTM D2626, or EasyLay underlayment, with
a minimum 4" wide side lap and a minimum 8" wide end lap, mechanically fastened to
deck.
Fastening: Approved nails and tin caps 6" o.c. within lap and two equally spaced staggered rows 12"
o.c. in the field (for Anchor/Base sheet only).
Membrane: All Tarco self -adhered membranes applied to approved Anchor/Base Sheet.
(See #15 in Installation Requirements for back nailing)
Surfacing: Approved Roof Assemblies as specified below.
Deck Type 3: Concrete, Non -Insulated
Deck Description: Structural concrete or concrete plank min. 2500 psi
System F(1): Membrane self -adhered to concrete deck.
Deck Preparation: The concrete deck shall be clean and dry and cured for a minimum of 28 days
Anchor/Base Sheet: None.
Fastening: Membrane shall be back nailed with approved concrete fasteners and 15/8" approved tin
caps at a maximum spacing of 9" o.c. at the head laps and be covered by the preceding
layer. No back nail fasteners or tin caps shall remain exposed).
Membrane: Tarco PS200HT self -adhered membrane applied directly to concrete deck.
(See Fastening above for back nailing)
Surfacing: Approved Roof Assemblies as specified below.
NOA No.: 16-1116.09
Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 12 of 15
C�
M
INSTALLATION REQUIREMENTS —TARCO SELF -ADHERED UNDERLAYMENTS:
1. Tarco self adhering underlayments shall be installed in strict compliance with applicable Building Codes.
2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors
Associations (NRCA) when installing Tarco self adhering underlayments.
3. During installation, comply with Occupational Safety and Health Administration (OSHA) safety standards; use
common sense measures and adequate safety precautions to prevent accidents.
4. Fast90 and PS200"r shall be acceptable underlayments for mechanically fastened roof tile and adhered roof tile
applications. MS300 and SS400 shall be acceptable underlayments for asphaltic shingles, wood shakes and
shingles, and slate or simulated slate roof assemblies. PS200"' and NR500"' shall be acceptable
underlayments for asphaltic shingles, wood shakes, shingles, and metal roof panel assemblies.
5. Re -fasten any loose decking panels, and check for protruding nail heads prior to the application of the Tarco
self adhering underlayments.
6. Tarco self adhering underlayments shall not be adhered directly over any pre-existing roof membrane.
7. All approved substrates are to be clean, dry and free of any loose debris or moisture prior to the application of
the Tarco self adhering underlayments. Refer applicable building codes prior to installation to verify
acceptable substrates.
8. Prime all metal collars, flashing, valleys, liner, drip edge and concrete deck substrate with ASTMD 41 primer,
water based acrylic or water based polymer modified primer.
9. Contractor may cut the underlayments into sections for workability and allow to relax prior to application.
10. Place the underlayments over metal drip edge in accordance with RAS l 11.
11. Install the first course of underlayment parallel to the eave edge.
12. Apply the underlayment, working from the center of the material continuously to the ends of the sheet (half of
the length of the sheet is the center); taking care to avoid wrinkles and ridges.
13. Remove the underlayments release film rapidly in a continuous fashion. Ensure the bottom adhesive side of
the membrane does not adhere to its self. In the event this transpires,separate the two layers immediately.
After some time, it may become impossible to do so without damaging the material.
14. It is recommended that end laps be staggered a minimum of 18" from the preceding course.
15. Underlayments are to be back nailed along the head lap. The nails shall be, 11 gauge 1'/4" approved ring shank
type applied with a minimum of a V/s" approved tin cap or approved capnail as required per the High Velocity
Hurricane Zone (HVHZ) section of the FBC, at a minimum rate of 9" o.c. The head lap of the preceding layer
of underlayment is to cover the area being back nailed.
16. Roll or broom the entire membrane surface paying special attention to all overlap areas "side laps, end laps, T-
joints" to ensure adhesion with acceptable substrates. A minimum of a 28 lb weighted roller may be used for
steep slope applications. The use ofa soft bristled push broom is acceptable on steeper slopes. The above
mentioned procedures are necessary in order to apply uniform pressure and allow for contact of the
membranes.
17. Apply Ys" thick uniform layer of SBS trowel grade modified bitumen asphalt adhesive / flashing cement
throughout the contact area of the 6" granule over granule and fabric over fabric end laps. Once the
aforementioned procedure has been completed, the membrane must then be hand rolled in place in order to
ensure contact of membrane and achieve a minimum of 1/80' asphaltic bleed out in designated area.
18. Tarco self adhering underlayments shall be applied to protrusions, slope changes, valleys, curbs, and other roof
top penetrations before any other sections of the roof.
19. When applying underlayments in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in each direction.
NOA No.: 16-1116.09
Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 13 of 15
w
20. For ridge applications, center the underlayment and roll from the center outward in both directions.
21. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product
Control Notice of Acceptance and applicable Building Code.
22. All protrusions or drains -shall be initially taped with a 6"piece of like kind membrane. "The flashing tape shall
be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of like kind
membrane shall be applied over the flashing detail.
23. Vertical strapping of Tarco self adhering membranes is acceptable.
GENERAL LIMITATIONS — TARCO SELF -ADHERED UNDERLAYMENTS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.
3. Tarco self adhering underlayments shall be applied only when material interface temperatures are 401 F and
rising.
4. Tarco self -adhered underlayments shall not be installed when any form of moisture such as water, dew, rain, etc.
is present on the substrate.
5. Tarco self -adhered underlayments are to be applied to a smooth, clean and dry surface, with the deck free from
irregularities.
6. Ensure roof has positive drainage prior to installation of Tarco self -adhered underlayments.
7. Tarco self -adhered underlayments shall not be applied over a pre-existing roof membrane or system.
8. After installation of Tarco self -adhered membranes, wait a minimum of 48 hours before roof loading of tiles.
9. Care should be taken during the loading procedure to keep foot traffic to a minimum and avoid dropping the
roof covering directly on the underlayment.
10 All tiles shall be staged (two tiles perpendicular to slope, four tiles on top parallel to slope) as per
manufacturer's requirements, not to exceed 6-high, to the standard maximum roof pitch of 6 :12 for flat tiles
and 6 :12 for lugged tiles (See Tile Staging Method diagram below).
At roof slopes greater than the above limitations, the use of loading battens or toe boards are required to load the
roof tile.
Tile Staging Method
Front View - Staged Tiles (Slope - )
Side View - Staged Tiles (Slope L)
NOA No.: 16-1116.09
MIAMMADECOUNTY
,..., , Expiration Date: 01l25/22
-- Approval Date: 01/12/17
Page 14 of 15
N a
11. The manufacturer reserves the right to change the tile staging method at any time as well as the number of tiles
stacked, not to exceed the preceding maximum number of tiles limitation.
12. EasyLay, PS200", MS300, SS400, and.NR500r'rshall not be left exposed as_a temporary roof for.longer than
30 days after application. PS200"' shall not be left exposed as a temporary roof for longer than 120 days after
application. Fast90 shall not be left exposed as a temporary roof for longer than 180 days after application. The
manufacturer reserves the right to change product exposure period at any time; not to exceed the preceding
maximum time limitations.
13. NR500rr' is not recommended for extreme high temperature environments such as under copper or zinc metal
roofing.
14. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of Tarco
underlayments with specific prepared roofing products. Tarco self -adhered underlayments may be used with
any approved roof coverings Notice of Acceptance listing Tarco self adhering underlayments or the ASTM
standard which the self adhering underlayments meet as a component part of an assembly in the Notice of
Acceptance.
If Tarco self -adhered mnderlayments or the ASTM standards are not listed, a request may be made to the
Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval
provided that appropriate documentation is provided to detail compatibility of the product, wind uplift
resistance, and fire testing results.
15. All products lined herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
MANUFACTURER'S CONSIDERATIONS:
1. When using Fast90 and PS200"r in tile roofing applications, use of loading battens or toe boards on roof slopes
greater than 6:12 and higher is recommended. When using EasyMop SBS in tile roofing applications, use of
loading battens or toe boards on roof slopes greater than 5:12 for Flat Tiles and 6:12 for Lugged Tiles and higher
is recommended.
2. Code body requirements supersede manufacturer's recommendations and installation guidelines.
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate
the installation of these materials.
LABELING:
All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city,
state and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County
Product Control Seal as shown below.
MIAMI•DADE COUNTY
END OF THIS ACCEPTANCE
NOA No.: 16-1116.09
Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 15 of 15
COUNTY
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE
Polyglass USA Inc.
llll W. Newport Center Drive FILE COPY
Deerfield Beach, FL 33442
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.gov/economy
SCANNED
BY
_�N` �t1� � IC[ 3 — p1 St. Lucie County
SCOPE: C_
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida. Building Code.
DESCRIPTION: Polyglass Polystick Underlayments THESE PLANSANDALL.PROPOSED WORK
ARE3UBJECTT� CORRECIIS H T
LABELING: Each unit shall bear a permanent label with the manufacturer's n
statement: "Miami -Dade County Product Control Approved", unless otherwiseWrYVININHAU APPUGABLECODES.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No.15-0410.04 and consists of pages 1 through 8. r� off pGNMEMS
D FAMS
CON SAB SDOFD
The submitted documentation was reviewed by Freddy Semino.; QiiaEco
v OA No.: 17-0614.22
MIAMI-DADE COUNTY ST. LUCIE COUNTY BUILDING DI ION Expiration Date: 09/13/21
REVIEWED FOR COMPLIANCE Approval Date: 07/06/17
REVIEIQ(E Y Page 1 of S
DATE
PLANS AND PER I MUST BE KEPT N OB
SITE OR NO INSPECTION(S) WILL E 'IADE
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: SBS , APP Self -Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Test Product
Product
Dimensions
Specification Description
Polystick IR-Xe
65' x 3'3?4"
ASTM D 1970 A fine granular/sand top surface self -adhering, APP
Manufacturing
Or 65' x 3'
polymer modified, fiberglass reinforced, bituminous
Location #1 & #2
60 mils thick
sheet material for use as an underlayment in sloped roof
assemblies. Designed as an ice & rain shield.
Polystick Dual Pro
61' x 3'3'/8"
TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester
Manufacturing
60 mils thick
ASTM D 1970 reinforced waterproofing membrane. Designed as a
Location 42
metal roofing and roof tile underlayment.
Polystick Tile Pro
61' x 3'3}/8"
TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester
Manufacturing
60 mils thick
ASTM D 1970 reinforced waterproofing membrane. Designed as a metal
Location #2
roofing and roof tile underlayment.
Polystick TU Max
65'8" x 33-3/8"
TAS 103 and A rubberized asphalt self -adhering, polyester reinforced
Manufacturing
60 mils thick
ASTM D 1970 waterproofing membrane. Designed as a a roof the
Location #1 & #2
underlayment.
Polystick TU P
32'10" x TV/s"
TAS 103 and A rubberized asphalt waterproofing membrane, glass -
Manufacturing
130 mils thick
ASTM D 1970 fiber/polyester reinforced, with a granular surface
Location #2
designed for use as a tile roof underlayment.
Po 10
A bberized 1 e• k 1' 1 es2 z
( ' tng}
8 ' utl dHiek
tD197{ x t°>:an x, a& �7ak
u he e
g° W�
Polystick MTS
65'8" x 33 3/s"
TAS 103 A homogeneous, rubberized asphalt waterproofing
60 mils thick
membrane, glass fiber reinforced with polyolefinic film
Manufacturing
on the upper surface for use as an underlayment for metal
Location #2
roofing, roof tile, slate tiles and shingle underlayment.
Polystick MTS Plus
65'8" x 3'3 Ya'
TAS 103 A homogeneous, rubberized asphalt "waterproofing
Manufacturing
60 mils thick
membrane, glass fiber reinforced with polyolefinic film
on the upper surface for use as an underlayment for metal
Location #2
roofing, roof tile, slate tiles and shingle underlayment.
Elastollex S6 G
32'10" x 3'3 %"
TAS 103 and Polyester reinforced, SBS modified bitumen membrane
Manufacturing
ASTM D 6164 with a sanded back face and a granule top surface. For
Location #2
use in roof tile underlayment systems.
NOA No.: 17-0614.22
nwm•DADECOUNTY Expiration Date: 09/13/21
` • • "- Approval Date: 07/06/17
Page 2 of 8
MANUFACTURING PLANTS:
1. Hazelton, PA
2. Winter Haven, FL
EVIDENCE SUBMITTED
Test Agency
Test Identifier
Test Name/Report
Date
Trinity ERD
P10870.09.08-RI
TAS 103
12/04/08
P10870.04.09
TAS 103/ASTM D4798 & G155
04/13/09
P33360.06.10
ASTM D1970
07/01/10
P33370.03.11
TAS 103
03/02/11
P33370.04.1 I
ASTM D 1623
04/26/11
P36900.09.11
TAS 103/ASTM D4798 & G155
09/01/11
P37300.10.11
TAS 110/ASTM D4798 & D1970
10/19/11
P40390.08.12-2
ASTM D 1623
08/07/12
P37590.07.13-1
ASTM D6164
07/02/13
P45270.05.14
TAS 103, TAS 110 & ASTM D1623
05/12/14
P46520.10.14
ASTM D1623
10/03/14
P44360.10.14
TAS 103 & TAS 110
10/07/14
P43290.10.14
ASTM D 1970 & TAS 110
10/17/14
PLYG-SC10130.06.16-3
TAS 103 & TAS 110
06/27/16
PLYG-10130.06.16-1
ASTM D1970 & TAS 110
06/27/16
PRI Asphalt Technologies
PUSA-035-02-01
TAS 103
09/29/06
PUSA-055-02-02
TAS 103
12/10/07
PUSA-089-02-01
TAS 103/ASTM D4798 & G155
07/06/09
Momentum Technologies, Inc.
JX20H7A
TAS 103/ASTM D4798 & G155
04/01/08
RX14E8A
TAS 103/ASTM D4798 & G155
11/09/09
DX23D8B
TAS 103/ASTM D4798 & G155
02/18/10
DX23138A
TAS 103/ASTM D4798 & G155
02/18/10
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved"
or the Miami -Dade County Product Control Seal as shown below.
MIAMI•DADE COUNTY
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the
installation of this materials.
NOA No.: 17-0614.22
Expiration Date: WARM
Approval Date: 07/06/17
Page 3 of 8
INSTALLATION PROCEDURES:
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or_wood.plank
System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick
TU P, Polystick TU Plus, Polystick NITS or Polystick MTS Plus, self -adhered.
Surfacing: See General Limitations Below.
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(2): Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type 11 or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Elastollex S6 G, hot asphalt applied
Surfacing: See General Limitations Below.
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o:c. at a minimum 4"head lap. (for
base sheet only)
Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6"
vertical laps.
Membrane: Polystick TU Plus, self -adhered.
Surfacing: See General Limitations Below.
NOA No.: 17-0614.22
MIAMMADECOUNTY Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 4 of 8
INSTALLATION REQUIREMENTS:
1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and
sweep the deck thoroughly to re move any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall
be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the
roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention
to lap areas.
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and Polystick MTS Plus may be
used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry
slate roof assemblies.
Polystick TU P may be used in all the previous assemblies listed except metal roofing.
Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems.
Polystick TU Max may be used in non-structural metal roofing and roof tile systems.
Elastoflex S6 G may be used in roof tile systems only.
3. Deck requirements shall be in compliance with applicable building code.
4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck
shall be free of irregularities.
5. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane
as a recover system.
6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the
amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
Exposure
Limitations (Days)
MTS
IR-Xe
Elastotlex
S6 G
TU
Plus
TU P
Tile Pro
Dual Pro
TU Max
MTS Plus
Winter Haven, FL
180
90
180
180
180
180
180
180
180
Hazelton,PA
N/A
90
N/A
180
N/A
N/A
N/A
180
N/A
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
NOA No.: 17-0614.22
MAMMADE COUNTY Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 5 of 8
Rule 61 G20-3 of the Florida Administrative Code.
S. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance.
Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive
set and mechanically fastened roof tile applications.
Polystick Dual Pro is limited to mechanically fastened roof tile applications.
Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in
Section 9.
Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile
applications.
9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximum roof slope
shall be as follows: (See Table Below)
Tile
Polystick
Elastoflex
Polystick TU Plus,
Polystick
Polystick
System (E3)
Profile
MTS
S6 G
TU P, Tile Pro,
TU Max
MTS Plus
MTS Plus with
Dual Pro
TU Plus
Flat Tile
Prohibited
4:12
6:12
6:12
5:12
6:12
without battens
Profiled
Prohibited
4:12
6:12
6:12
4:12
6:12
Tile
without battens
The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System
Notice of Acceptance and applicable Florida Building Code requirements. When battens are required, they shall
be utilized during loading and installation of tiles.
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure — two tiles
laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles — for
all underlayments except Polystick MTS which shall be loaded onto battens.
POLWTICKTU PWs
NOA No.: 17-0614.22
MLAMMADECOUNTY Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 6 of 8
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU
Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick NITS Plus or Elastoflex S6 G may be
used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro,
Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS
Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance.
If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick
TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the
Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided
that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire
testing results.
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are
cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable.
Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 1 I gauge ring shank type, applied with a minimum I V metal disk as
required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate
of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being
back -nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between
the application of the lap. The use of mastic between the laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile
Loading Guidelines. See General Limitations #9 and #10.
6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for
pitch/slopes of 7/12" or greater. It is suggested that on pitch/slopes in excess of 6 %<"/12", precautions should be
taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed
roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified
Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the
Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching
membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so
that water will run parallel to or over the top of all laps of the patch.
NOA No.: 17-0614.22
MIAMI•DADECOUNTY Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 7 of 8
10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a
minimum of 40 Ibs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for
rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished
upon request by our Technical Services Department by calling I (800) 894-4563.
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 894-4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by
the National Roofing Contractors Association (NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
END OF THIS ACCEPTANCE
NOA No.: 17-0614.22
Expiration Date: 09/1321
Approval Date: 07/06/17
Page 8 of 8