Loading...
HomeMy WebLinkAboutSUNLAST METAL - NAIL STRIPC,Dunlast Metal Value Engineered Meta/ Roofing Tm FLORIDA PRODUCT APPROVAL STUART LINE SERIES( —AP NAIL STRIP;):: � '� ` 24'G�A 16" ROOF PANEL OVER_15,�2t=�PLYWO�OD�� �'���•�' SCANNED Product Evaluation Report BY St. Lucie County 1.0 Nail Strip/SnapLock Seam Roof Panel over 15132" Plywood Florida Product Approval # 21423.8 Florida Building Code 2017 6th ed Per Rule 61G20-3 Method: 1—D Category: Roofing Subcategory: Metal Roofing Compliance Method: Rule 61G20.3 HVH2 Product Manufacture_ r. Sunlast Metal 2120 SW Poma Drive Palm City, Florida 34990 Enelneer Evaluator. Vane G. Marotta, P.E. FL reg # 82591 1915 NE 45°i ST. #107 Fort Lauderdale, FL 33308 954-776-8004 Validator: Locke Bowden, P.E., FL#49704 9450 Alysbury Place Montgomery, AL 36117 3, o FILE COPS Diane G. Marotta, P.E. FL reg # 82591 seal -�;".'\��=ivS� •'•' Tom'-,, G.. Page 1 of 4 Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2, 1507.1.1, 1507.4.3, 1518.9, 1523.6.5.2.4 Product Description: 24GA Panel,16" Nail Strip/snap lock mechanical attached 16" Coverage Width Roof panels 1.0" Rib height Panel thru fastened; into 15/32" APA Plywood decking. Non-structural Application. FOR USE IN HVHZ. Material: 24GA Steel, Galvalume conforming to Florida Building Code 2017 Section 1507.4.3 56ksi yield strength min. Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3 and Section 1517 for HVHZ Fastener: #10 X 1" Pancake -Head wood fasteners or equivalent. 3/16" minimum penetration through support. Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6,1507.4.4 Sealant: Bostick Chem Calk 915 (Silyl modified polymer (SMP) apply 1/16" bead atop rear leg of male joint, adjacent to fasteners continuously along entire length of panel. 15/32" APA plywood, plywood supports at maximum 24' O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2017 and RAS 133. TABLE A Safety factor of 2:1 included Design Pressures Field Perimeter/Corner Max Design Pressure -84.25psf -136.75psf Fastener Spacing 12" o.c. 6" o.c. Fastener Size #10 #10 Insulation: Optional Rigid Insulation board, 3" max thickness compliant with FBC 2017 section 1508.2 Quality Assurance: In accordance with FBC 2017 and Rule # 61620-3: Keystone Certification, Inc. QUA 1824 Test References: Hurricane Test Laboratory (TST1527) 0412-0306-06 RA TA5125-2003 Architectural Testing Inc (TST 1527) # 0412-1203-07 and 0412-0621-07 TAS 125-2003 Architectural Testing Inc. (TST 1527) C6413.01-450-18 REV 1 TAS 125-2003 PRI Construction Material Technologies(TST5878) SFMS-002-02-01 R3 TAS 100-1995 PRI Construction Material Technologies(TST5878) AKZC-001-02-01/05 ASTM B 117-2002 PRI Construction Material Technologies(TST5878) AKZC-001-02-01/05 TAS 110-2000 AKZO Nobel Coatings, Inc. Lab Form ASTM G 153 Code Compliance: The product described herein demonstrated compliance with The Florida Building Code (FBC) 2017 Section 1504.3.2., 1523.6.5.2.4.1. The product evaluation is limited to compliance with the structural wind load requirements of the FBC 2017, as relates to Rule 61G20-3. Minimum Slope Range 2/12 Minimum Slope per Florida Building Code 2017, and in accordance with Manufacturers recommendations. Installation: Install per manufacturers recommended details in compliance with FBC 2017 and RAS 133 Underlayment: Per Manufacturers installation guidelines per Florida Building Code 2017, Chapter 1507 Chart 1507.1.1 Roof Panel Fire Classification: No classification. Shear Diaphragm: values are outside the scope of this report. Page 2 of 4 Design Procedure: Based on the dimensions of the structure, applicable wind loads are determined using Chapter 16 of the Florida Building Code 2017 -roof cladding wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. Design professional shall select the applicable erection details to reference in drawings for correct fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be compliant with Florida Building Code 2017 Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading. Required wind loads shall be determined per project per FBC 2017 and any rational analysis computation shall be prepared by a licensed design professional. Certificate of Independence: Diane G. Marotta, P.E. does not have nor will acquire financial interest in any company manufacturing or distributing products under this evaluation. Diane G. Marotta, P.E. is not owned or operated or controlled by any company manufacturing or distributing product under this report. PRODUCT EVALUATION REPORT Page 3 of 4 5unlastMetal Value Engineered Meta/ RooFng Tm TABLE A #10 X 1" Pancake -Head wood fasteners or equivalent. 3/16" minimum penetration through support Roof Areas Field Perimeters and Corners Maximum Design Pressures-84.25psf -1363S psf Screw Spacing 12" o.c. 6" o.c. INSTALLATION METHOD DRAWINGS TYPICAL ASSEMBLY PROFILE VIEW 16" Coverage Striations Optional TYPICAL ASSEMBLY ISOMETRIC VIEW Bead of Bostil, � chernC um 915 adhesive � 2: penes 5padna rj' I" as par TahM A herein Page 4 of 4