HomeMy WebLinkAboutNOARF�FtyFO
MAR O'?O70
PeFrn
r,4_
'ce unKyent -PRODUCTCONTR0LSECTION
--DEPARTMFddT_OF REGULATORY APRCONOMIC RE86URCES MW 11805 Sw 26 Shell. Roem208
DOARDANDCODE,ADNRaSrRATIONDIMON - - -- rg-2590rm786?315-250
- T (766) 3152590 P (/86) 313-2599
MFMBuildingProducta COrporation t✓ 1Z�m � I �® ( �S SCANNED
Orange EiLE: COPY BY
Coshocton, OH43812 St. Lucie County
SCOPE: a use of const-ruauon materials. The.
This NOA is being issued "under the applicable rules and regulations governing th
documentation submitted has beta reviewed and accepted by Miami Dade County RBR - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Autilority Having Jurisdiction (AIU).
This NOA shall not be, valid after the expiration date stated below. The Miami -Dade County Product Control Section
-(hi Miami Dade County)'and/or the AHJ (in areas other than Miami Dade County) re to the tight t. have.thia
product or material tested for quality asamince purposes: If this Product or material fails to perform is the accepted
manner, the manufactom will incur the expense of each testing and the AHf may immediately revoke. modify: or
suspend the use of such product or materiel within their jurisdiction RBR reserves the tight to revoke this acceptance,
if it is determined by Mia ni-Dade County, Control See that this product or material fails to meet the
requirements of the applicable building Cade.
This product is approved as descn'bea herein, and has beendemped to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Ultra HT Wind &'Water Seal" High Temperature
LABELING: Each unit shall hear a permanent label with the manufactutets name or logo, city, state and following
;statement:' "Miami -Dade County Prodact Control Approved". unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been Sled and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or Process. Misuse of this NOA as an endorsement of any product
on
for sales, advertising or any other purposes shall automatically terminate this NOA Failure to comply with any
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT:is displayThe NOA number preceded by the words Miami -Dade County, sphy a and followed by the
ed, then it shell be done
If any portion of the NOA
expiration date may be displayed is advertising literature.
in its entirety.
kjSpECI'ION: A copy of ibis entire NOA shall be provided to the user by the memrfsotu er or its distributors and .
shall be available for inspection at therjob site at the request of the Building Official
This NOA consists of pages 1 through 3.
The, submitted do arum ation was reviewed by Juan E. Collao, RA-
- •'r "
eaeoveoi
NOANo.: 13-1125M
Esphst9on Date: 03M/19
Approval Date: OW114
page 1 of 3
ROOFING COMPONENT APPROVAL
Roofing
Sub-Cate¢orv' Underlayment
Material: SBS
SCOPE: This acceptance is for Ultra HT Wind and Water See High Temperature roof underlayment as described in this
Notice of Acceptance, for use with approved prepared roof assemblies. '
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABFi BY APPLICANT:
Product Dimensions
Ultra HT Wind and Water 36' x 67' rolls
See High Temperature
MANUFACTURING LOCATION:
L Coshocton, OH
EVIDENCE SUBM TED:
Test Agency
PRI Construction Materials Technologies,
Inc.
Test Product
Saeci fiuni Descriation
ASTM D 1970 45-mils flick (nominally), self adhering,
membrane composed of a white, non -slip cross -
laminated polymer film, laminated to a
rubberized asphalt adhesive with a split release
liner.
Test Identifier Test Name Ienort Date
NFM-039-Ml ASTM D1970 W15/13
APPROVED ASSEMBLIES:
Deck Type 1: Wood, non -insulated
Deck Descripdon New construction or reroof minimum 19/3' or greater plywood or wood plank.
System E(1): Anchor sheet mechanically fastened deck, membrane adhered.
Base Sheet: One or more plies of ASTM D 226 Type B or ASTM D 2626 with a minimum 4" head lap and a
6' end lap mechanically fastened to deck with approved nails and tin caps 6" v.c. at the laps and
two staggered rows 12" o.c. the field of the roll.
Membrane: One or more plies of Ultra HT Wind & Water ScC High Temperature tmderlayment with a
min amn 3" side lap and 6" end lap. Place the fast course of membrane parallel to the cave,
rolling the membrane to obtain'masimnm contact Remove the release membrane as the
membrane is applied.
Surfacing: Approved for mechanically fastened metal roofing, aspWtic shingles, wood shakes and shinges,
quarry slate roof assemblies.
NOA No.: 13-IM.06
o>eeou Esphation Date: 03f17/19
Approval Date: 03/27/14
Page 2 of 3
LDMATIONS•
- -- _ ---L--Fire Classificationis.not-part-of this acceptance.- -- -- -- -- ----- — ---
2. This acceptance is for prepared roofing applications. Minimam deck requirements shall be in compliance with
applicable building code. Ultra HT Wind & Water Seal` High Temperature underlayment shall be installed in
strict compliance with applicable Building Code.
3. Ultra HT Wind & Water Seal High Temperauneundetlayment may be used in mechanically fastened metal
roofing, asphaltic shingles, wood shakes and shingles, quarry slate roof assemblies. Ultra HT Wind & Water
Seal` High Temperatureunderlaymem shall not be used as roof tile underlayment.
4. Ultra HT Wind & Water Seal High Tempersuma mderlayment shall be applied to a smooth, clean, and dry
surface with deck free of irreeitiarities.
5. Ultra IJT Wind & Water Seal Hrgh Temperatureunderlayment shall not be applied over an existing roof `
membrane as a recover system.
6. Ultra HrVind & Water Seal'". High Temperatureunderlayment'ball not be left exposed as a temporary roof for
longer than 30 days of application.
I. Referto prepared Roofing system product Control Notice of Acceptance for listed.approval of this product with
specific, prepared roofing products.
& Ultra HT Wind & Water Seal` IIigh Temperaturcunderlayment may be used with any approved roof coveting
Notice of Acceptance listing Ultra HT Wind & Water`, Seal"° Hrgh Temperatareunderlaymelit as a component
part of an assembly in the Notice of Acceptance. if itis.not listed, a�uest may be made to the Authority
I3Aving Jurisdiction (Alm or the Miami -Dade County Product Control Department for approval provided that
appropriate dwumentation is provided to detail compatibility of the products, wind uplift resistance, and'fire
testing results.
9. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions. For ridge applications, center the membrane and roll from
the center outward in both directions.
10. Roll or 6momthe entire membrane surface so as to have 100% contact with the surface. giving special attenUon
AD overlap areas.
11 Plash vempipes stacks, chimneys and penetrations in compliance with Roof Assembly. current product Control
Notice of Acceptance'and applicable Building Code.
12 AIL protrusions or drains shall be'initially taped with a 6' pieta of underlayment. The flashing tape shall be
pressed in pL>ce and"formed around'the protrusions to ensure a tight fit. A second layer of Ultra HT Wind ;&
Water Seat'" ifigh TempersUuemtderlaymentshall beapplied over the nnderlayment.
13. All products listed hettsin shall have a quality asetuance audit in accordance with the'Plorida Building Code and
Role 61G2(L3 of the Florida Administrative Code. of the mannfacUuer'a name or lbgo,
14. All membranes or pacloitging shall bear the imprint or idanti5able marbing
city and state of manufacttsing facility, and the following statement "Nfiami-Wade County product Control
- Approved" or the Miami<Dade County product Control Seal as shown below.
nata►nnoecourm ,
END OF THIS ACCEPTANCE
NOA No.: 13-1125.06
Eapiratton Date: 03/27/19
ApprovaiBatet 03/27/14
Page 3 of 3