25'-10"
I
I
I
I
1
I
I
T-6"
I:
21'
30'
-- --__, 25'LAKESETBACK----------------
AUTO -FILL DEVICE
112" FRESHWATER St IPPLY LINE FROM EX.
HOSE BIBB - BY OTHERS
FIELD VERIFY H.B. LOC.
& 2" OVERFLOW LINE TO ON -SITE DRAINAGE 4L
SYSTEM
---------------`------- ------ �. PERIMETER BONDING
WIRE @ 18"MIN. - 24" MAX.
6, I FROM W.L. (SEE DETAIL) .
I-- — — ---T-----------------------
I I.
15'
9'
POOL/SPA EQUIP.
SEE SITE PLAN:
BY OTHERS
REINFORCED OR PRODUCT
APPROVED
CONCRETE SLAB(S)
(FIELD VERIFY SIZE &
LOCATION)
9'-4"
6'
30' 11 21'
N.T.S.
— — — - — — — — — — — — --- — — — — — — — - — — — — — — — — ---------
FOOTING FOR SCREEN I
ENCLOSURE -SCREEN
- 8" ENCLOSURE BY OTHERS .
I C I 18 STEP (4) INLETS SKIMMER I
I
I I 6" BELOW I
• I W.L. I AQUASTAR32CDFL-32" I 2" STATIC LINE TO
AUTO -FILL DEVICE
I I CHANNEL DRAIN (316 GPM @ 3.9 I W/ APPR. COVER
I 2.5" SCH I FT/SEC THRU GRATE - SINGLE;
40 I UNBLOCKABLE COMPLIANT W/ 2.5" SCH
ASME/ANSI A 112.19.8 - 2017 I 40
�r OR EQUAL
I I 1 I I I
i .
F F I
18" BENCH - I o-
I 18" BELOW I� IFn o
I I W.L.
I I STUB -OUT FOR (2) LED LIGHTS
I STEPS
I I I POOL CLEANER I 240 SQ. IN. MIN.
TOPTREAD
I
T_— I �— --
12"
-------------------L----------
L� 12" I
.S" SCH 40
— 4 — I'
— -- J
NOTE:
PROVIDE WINDOW AND DOOR
ALARMS ON ALL OPENINGS
THAT LEAD ONTO POOL AREA
PER FBC SIXTH EDITION, 2017
EXIST. RESIDENCE
POOL/SPA LAYOUT & PIPING PLAN
SCALE: 1/4"=F-0"
EXIST. PORCH
3" SCH 40
8"
12" RAISED SPA.
18" BENCH - 20" BELOW W.L.
18" X 18". CORNER STEP .
(4) THERAPY JETS
(2) FILTERED INLETS '
(1) AQ UASTAR 32CDFL - 32" CHANNEL
DRAIN (316 GPM (a•3.9 FT/SEC THRU GRATE
- SINGLE,IINBLOCKABLE OR EQUAL)
SPA SIDE AIR SWITCH
(1) I.ED SPA LIGHT - NICHE'LESS '
(1) 30"'WIDE SPILLWAY
TILE BACKSIDE OF SPA DOWN TO DECK
NnTF
POOL CONTRACTOR TO VERIFY ALL
PROPERTY LINE LOCATIONS AND POOL
ELEVATION PRIOR TO CONSTRUCTION.
POOL LAYOUT AND DIMENSIONS TO BE
VERIFIED W/ OWNER PRIOR TO
CONSTRUCTION
a
NOTE:
THESE PLANS ARE FOR POOL AND SPA
STRUCTURES, PLUMBING,
EQUIPMENT/ELECTRICAL & DECK
ONLY. ALL OTHER FEATURES
DESIGNED BY OTHERS.
33'-5"
FEB 2 0 2011r
Permitting Deparlffiigt
St, WOW County
FILE COPY
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
RECEIVE[T
MAR 0 71018
Permitting Department St. Lucie County
I
I
.. M
CAA
Fu
a
w
`ll/►H1AII'll���i
O O;
o 6 09 m 4
:
'*
LLI M
Q 0:. z
o
w
y��e S * P P0+
•
Z M 00 1n
r-1 in
~ en 00
rI�
�
v � ;To �
aV0000wl
00 a
V
W
W
A
H
x w
a�
aU
a W
O F"
F F
O
O
a
aw
0
N
O
00
SCANNED
BY
St. Lucie
County
Y:
BY:
:
9
:
ED
ER:
9
IF 2
SAND SET, INTERLOCKING
PAVER DECK
BULLNOSE
BRICK COPING SLOP DECK @ y" PER. FOOT
3" -..I
m
a�q
y Fr,
z>i
MARCITE M 3 3
OR EQUAL
CLEAN FILL COMPACTED TO
95% MAX. DRY DENSITY
� i UNDER DECK ONLY
i 2 - #J DIA. REBAR
TOP OF BEAM
REINFORCING ST
6„ 3 #3 DIA. REBAR
i12" O.C.E.W.-
RADIIUS 14- t .. WALLS & FLOOR
VARIES
TYPICAL WALL SECTION
1411
s�
m ;
PIPE REDUCED TO I"
z
AND RUN TO DECK
3
/ BOX
2" SCH 40 PVC CORD
LED LIGHT SLEEVE
SP 10-22 WALL
FITTING - OR EQUAL
INSTALLED INSIDE PIPE
LED LIGHT DETAIL
W.L.
08 SOLID BARE COPPER BOND
WIRE W/ APPR CLAMPS
(ONE ON EACH SIDE OF
POOL-47OTAL)
18" MIN: 24" MAX.
(ENTIRE PERIMETER)
r i -
(1) #8 SOLID BARE COPPER WIRE
BONDED TO POOL STEEL AS SHOWN
NOTE: BONDING WIRE REQUIRED AT PERIMETER OF POOL
EQUIPOTENTIAL BONDING DETAIL
PER FLORIDA BUILDING CODE ADAPTATION OF
N.E.C. 2014 SEC. 680.26
WATER LINE
Z
VACUUM FITTING W/
SELF -CLOSING SAFETY COVER
(HAYWARD MODEL #400
OR EQUAL)
VACUUM LINE DETAIL
(WHEN APPLICABLE)
- _
�R
� BELOW
SUB-GRADE
#3 DIA. REBAR
@ 12" O.C.E.W.
DEEP END
STEP/BENCH
SECTION
2 518"
GRADE LOT TO SLOPE
AWAY FROM POOL DECK
SCREEN ENCLOSURE
/ (BY OTHERS)
/ 12" BRICK
PAVER DECK
1/2"1 ' L - SAND'BED"
12"
12" X 12" FOOTING
1211 W/(2) #5 DIA. CONT.
FOOTING FOR SCREEN ENCLOSURE
STEP BEYOND
811 811
9'-411
1811
122 11
i 1211
2011
CLEAW.L.
�j
�' j 6 , 811
N '--
COMPACTED 1 - IL k #3 DIA. REBAR
7-7 y\ @ 6" O.C.E.W.
r IN SPA WALLS
SPA N1+:UTION
SCALE: 3/8" =1'-0"
- 31 t 4'-611
12" 12" 12"
4'
SKIMMER COVEROL ADJUSTABLECW/ LAR
1'_� I'T
HEATER (GAS) - IGNITION SWITCH
3. #12 THHN CU WITHIN 1/2" CONDUIT
(CONNECT TOP 20 AMP - 1 POLE GFCI
BREAKER) MANUAL MOTOR STARTER SWITCH
POOL PANEL W/ 30 AMP
(100% RATED) 2-POLE BREAKER 2.7 HP PUMP MOTOR W/ BUILT-IN
OVERLOAD SWITCH W/ 3 - #10 THEN
CU WITHIN 1/2" MIN. CONDUIT
(CONNECT TOP 20 AMP - 2 POLE GFCI
(3) - #10 &(1) #12 GROUND BREAKER)
THHN CU IN 1/2" RPVC S.P.S.T. TOGGLE
CONDUIT SWITCH
(2) LED POOL LIGHTS 12 VOLT TRANSFORMER
(GFI NOT REQUIRED) JUNCTION BOX
(1) LED SPA LIGHT
( GFI NOT REQUIRED)
1. ALL ELECTRICAL TO COMPLY WITH 2O14 NATIONAL ELECTRIC CODE,
ELECTRICAL CONTRACTOR TO VERIFY ADEQUATE CAPACITY
AT POINT OF CONNECTION.
2. 3412 THHN CU WITHIN 1/2" MIN. CONDUIT FOR POOL LIGHT(S).
3. GROUND ALI, BOXES, LIGHTS, MOTORS, ETC. w/ #8 SOLID, BARE COPPER.
4. PROVIDE W.P.G.F.I. OUTLET 10' MIN. - 20' MAX. FROM WATER'S EDGE.
5. ALL POOL PUMPS TO BE GFCI PROTECTED PER NEC 680.22(B).
6. LOAD CALCULATIONS FOR EXISTING SERVICE AND PANEL - BY OTHERS.
WRAP (2) #3 DIA. AROUND
SKIMMER TIED TO POOL STEEL
LEAF BASKET
7-
TO POOL PUMP
25 GPM MIN. FLOW
SKIMMER DETAIL
ELECTRICAL DIAGRAM
N.T.S.
AQUASTAR32CDFL-32" T-32 --f 33/32
CHANNEL DRAIN (316 GPM
@ 3.9 FT/SEC THRU CRATE -
HYDROSTATIC RELIEF VALVE
SINGLE UNBLOCKABLE
PORT OR CAP OFF
OR EQUAL 3 I/4
FLOOR
FINISH PLASTER
MAIN DRAIN SUCTION LINE
HYDROSTATIC RELIEF VALVE &
TIED TOGETHER AS SHOWN
PERFORATED PVC COLLECTION
ABOVE - PIPE SIZE PER
TUBE, WHERE REQUIRED -
PLAN
MIN. Y22 YARD GRAVEL SUMP
NOTE: 25.9 SQUARE INCH OPEN AREA,
WRAPPED W/ DRAIN FEILD
316 GPM = 3.9 FEET PER SECOND
CLOTH (RECOMMENDED)
Channel Main Drain Detail.
SCALE: N.T.S.
30' PUMP FRAME OR FILTER
TANK MOUNT OR HEATER
16'-6" 6' ANCHOR POOL PUMP AND
FILTER PER MFGR'S N.O.A.
4" THICK REINFORCED CONCRETE SLAB
��- 2" MIN.
1 7.08' 31 !611
5'-10" 1' FSLOPE i
POOL SECTION
TYPE 'O' POOL
FILE COPY
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
POOL SYSTEM FLOW RATE: 150 GPM
(MAXIMUM FLOW FROM PUMP CURVE)
REC. PUMP = 2.7 HP JANDY E-PUMP - JEP2.OSVRS
VARIABLE SPEED - LOW SPEED = 36 GPM MAX.
HIGH SPEED = 150 GPM @ 42 TDH
3" SUCTION PIPE @ 150 GPM = 6.63 FT./SEC.
(8 FT./SEC. MAX. - SUCTION LINES)
2.5" BRANCH PIPE @ 75 GPM = 5.13 FT./SEC.
(6 FT./SEC. MAX. - SUCTION LINES)
3" PRESSURE PIPE @ 150 GPM = 6.63 FT./SEC.
(10 FT./SEC. MAX. - PRESSURE LINES)
CARTRIDGE FILTER = 150 GPM @ 1 GPM/ SQ. FT.
= 150 SQ.'' FT. MIN. FILTER AREA
FILTER',-10-
POOL PUMP, FILTER Xi
AND HEATER ANCHOR -
POINTS MAY VARY
POOL EQUIPMENT ANCHORING DETAIL
SEE MFGR SPECIFICATIOP' IR ADDITIONAL ANCHORING
INFORMATION -EQUIPMEN--lHAPES MAY VARY
O
EQUIPMENT LAYOUT
SCALE: N.T.S.
LEGEND
1. 3" SPA MAIN DRAIN LINE
2. 2" VACUUM LINE
3. 3" POOL MAIN DRAIN LINE
4. 2" SKIMMER LINE
5. 3" SPA JET LINE
6. 3" SPA RETURN LINE
7. 3" POOL RETURN LINE
A. 1.5" TO WASTE OR DISCHARGE
TO GROUND
B. 2.7 HP REC. PUMP W/ APPROVED HAIR
& LINT STRAINER
C. CARTRIDGE FILTER W/ PRESSURE
GAUGE AND AIR RELIEF VALVE
D. 400,000 BTU GAS HEATER W/
INTERNAL BY-PASS
E. CHLORINE GENERATOR
F. INSTALL PERMA-CAST PB-2011 WATER BOND
OR APPROVED EQUAL TIED TO
PUMP GROUND W/ #8 SOLID COPPER
& APPROVED LUG (MIN. 9 SQ. IN
SURFACE AREA EXPOSED TO WATER)
PER MFGR'S SPECS (FIELD VERIFY LOCATION)
G. VALVES (TYPICAL)
GENERAL NOTES:
1. ALL LIGHTS, LADDERS, HANDRAILS, REINFORCING STEEL SHALL BE
GROUNDED PER CODE,
2. POOL TO BE CONSTRUCTED OF CONCRETE/GUNITE WITH A MINIMUM
COMPRESSIVE STRENGTH OF 4000 P.S.I. AT 28 DAYS.
3. ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS
OF NEW BILLET STEEL, CONFORMING TO ASTM A-615, GRADE 60, STEEL SHALL
BE BENT, LAPPED AND PLACED IN ACCORDANCE WITH ACI STANDARDS.
4. GRATE IN MAIN DRAIN SHALL HAVE A FREE AREA OF 4 TIMES THE AREA OF
THE SUCTION LINE.
5. STEPS TO HAVE A 10" MINIMUM TREAD AND A 12" MAXIMUM RISER
6. POOL TO BE FENCED PER LOCAL CODES.
7. GATES TO BE SELF -LATCHING, SELF -CLOSING AND LOCKABLE.
8. DESIGN, CONSTRUCTION AND WORKMANSHIP SHALL BE IN CONFORMITY
WITH THE REQUIREMENTS OF ANSI/ NSPI 3; ANSI/ NSPI 4; ANSV NSPI 5;
ANSI/ NSPI 6; AND ANSI/APSP 7 2013 AND ANSI/APSP.ICC-15 2011.
9. SPAS AND HEATED SWIMMING POOLS SHALL BE EQUIPPED WITH A COVER
DESIGNED TO MINIMIZE HEAT LOSS. EXCEPTIONS: OUTDOOR POOLS
DERIVING OVER 70 PERCENT OF THE ENERGY FOR HEATING FROM
NON-DEPLETABLE ON -SITE RECOVERED SOURCES COMPUTED OVER AN
OPERATING SEASON ARE EXEMPT FROM THIS REQUIREMENT.
10. ALL FEATURES OF THE POOL/SPA SHALL BE INSTALLED IN COMPLIANCE WITH
THE FBC SIXTH EDITION (2017) - RESIDENTIAL -PRIVATE SWIMMING POOL AND
LOCAL AMENDMENTS, IF ANY.
11. RESIDENTIAL SWIMMING POOL BARRIER SHALL COMPLY WITH FBC SIXTH
EDITION (2017) - RESIDENTIAL CHAPTER 45 - PRIVATE SWIMMING POOL.
12. PRESUMPTIVE LOAD - BEARING VALUE OF SOIL - IN ACCORDANCE WITH FBC
SIXTH EDITION (2017) SECTION 1806.2 THE SOIL BEARING VALUE SHALL BE A
MINIMUM OF 550 P.S.F. BASED ON A MAXIMUM OF 1/8" SETTLEMENT.
13. SHOULD ANY MUCK, MARL, OR OTHER ORGANIC SOILS BE DISCOVERED ON
EXCAVATION, THEY SHOULD BE REMOVED IN THEIR ENTIRETY, ALL
CONSTRUCTION SHALL STOP AND THE ENGINEER OF RECORD SHALL BE
CONTACTED TO CONDUCT AN INSPECTION.
14. POOL CONTRACTOR/OWNER BUILDERS TO VERIFY ALL POOL DIMENSIONS,
POOL LOCATION AND SETBACKS PRIOR TO CONSTRUCTION.
(CONTACT ENGINEER IF ANY DISCREPANCIES OCCUR)
15. POOL PLANS ARE DESIGNED TO MEET THE FBC SIXTH EDITION (2017) -
RESIDENTIAL - PRIVATE SWIMMING POOLS.
16. ENTRAPMENT PROTECTION FOR SUCTION OUTLETS SHALL BE INSTALLED IN
ACCORDANCE WITH REQUIREMENTS OF ANSI/APSP 7-2013 AND FBC SIXTH
EDITION (2017) - RESIDENTIAL CHAPTER 45,
PLUMBING NOTES:
1. ALL PIPING, EQUIPMENT AND MATERIALS USED IN THE PLUMBING SYSTEM OF
SWIMMING POOLS THAT ARE BUILT IN PLACE SHALL CONFORM TO THE FBC
SIXTH EDITION (2017), PLUMBING, CHAPTER 45 - PRIVATE SWIMMING POOLS.
2. POOL PIPING SHALL BE DESIGNED SO THE WATER VELOCITY WILL NOT
EXCEED 6 FT/SEC ON BRANCH SUCTION LINES, 8 FT/SEC. ON SUCTION LINES
AND 10 FT/SEC. PRESSURE LINES.
3. VALVES SHALL BE MADE OF MATERIALS THAT ARE APPROVED IN THE
FLORIDA BUILDING CODE, PLUMBING. VALVES LOCATED UNDER CONCRETE
SLABS SHALL BE SET IN A PIT HAVING AT LEAST A DIMENSION OF FIVE
DIAMETERS WITH A MINIMUM OF AT LEAST 10 INCHES AND FITTED WITH A
SUITABLE COVER ALL VALVES SHALL BE LOCATED WHERE THEY WILL BE
READILY ACCESSIBLE FOR MAINTENANCE AND REMOVAL.
4. WHERE CHECK VALVES ARE INSTALLED, THEY SHALL BE OF THE SWING OR
VERTICAL CHECK PATTERN.
5. ALL HEATERS SHALL BE EQUIPPED WITH AN APPROVED PERMANENT BY-PASS
OR ANTI -SIPHON DEVICE INSTALLED TO PROVIDE A POSITIVE MEANS OF
RETAINING WATER IN THE HEATER WP-N THE PUMP IS NOT IN OPERATION.
6. ALL POOL PIPING SHALL BE 1.5" SCH. 4L. ✓C EXCEPT AS SHOWN AND SHALL
BEAR THE H.S.P. SEAL OF -APPROVAL.-
'/. THIS POOL/SPA IS DESIGNED TO W1THS' NO HYDROSTATIC UPLIFT FORCES
WHEN EMPTY, FOR WATER TABLE UP Ttr3'-O" BELOW POOL/SPA DECK
ELEVATION. HOWEVER, DUE TO SEASONAL VARIATIONS IN THE WATER TABLE
ELEVATIONS, ALL POOL/SPA SHALL BE FITTED WITH A HYDROSTATIC RELIEF
VALVE.
3. WATER SUPPLY AND DISPOSAL SHALL BE ARRANGED SO THERE IS NO CROSS
SUCTION WITH A DOMESTIC WATER SUPPLY OF WATER DISPOSAL.
9. UNLESS AN APPROVED TYPE OF FILLING SYSTEM IS INSTALLED, ANY WATER
SUPPLY WHICH IN THE JUDGEMENT OF THE ADMINISTRATIVE AUTHORITY
MAY BE USED TO FILL THE POOL IF EQUIPPED WITH BACKFLOW PROTECTION.
NO OVER -THE -RIM FILL SPOUT WILL BE ACCEPTED UNLESS LOCATED UNDER
A DIVING BOARD, OR PROPERLY GUARDED.
10. ALL POOL/SPA PIPING SHALL BE INSPECTED AND APPROVED BEFORE
COVERING OR CONCEALING. IT SHALL BE TESTED AND PROVED TIGHT TO
THE SATISFACTION OF THE ADMINISTRATIVE AUTHORITY, UNDER A STATIC
WATER TEST OR AIR PRESSURE TEST OF NOT LESS THAN 35 PSI FOR 15
MINUTES
11. JOINTS AND CONNECTIONS SHALL BE MADE AS REQUIRED BY THE FLORIDA
BUILDING CODE, PLUMBING.
12. ALL WATER HEATING EQUIPMENT SHALL BE INSTALLED WITH FLANGES OR
UNION CONNECTION ADJACENT TO THE HEATER.
13. PURPLE PRIMER REQUIRED ON ALL PVC PIPING PER FBC SIXTH EDITION (2017).
14. ' GAS PIPING SHALL COMPLY WITH FLORIDA BUILDING CODE FUEL GAS.
(SEPARATE PLANS AND PERMIT REQUIRED)
15. SWIMMING POOLNPA WATER HEATERS SHALL BEAR THE LABEL OF A
RECOGNIZED TESTING AGENCY.
16. PROVIDE APPROVED BACKFLOW DEVICE AT WATER METER AND PRESSURE
VACUUM BREAKER BACKFLOW DEVICE ON WATER SUPPLY WHEN REQUIRED.
POOL SPECIFICATIONS
SIZE: 15'-0" X 30'-0" DEPTH: X-6" TO 5'-10"
VOLUME: 182700 GALLONS ELEVATION: DET. ON SITE
TURN OVER RATE: 8.7 HR. (� 36 GPM MAX. - LOW SPEED
(TURN OVER RATE: 2.1 HR. * 150 GPM - HIGH SPEED)
DESIGN FLOW RATE: = 18,700 GAL./6 HRS./60 MIN. = 52 G.P.
TILE: STANDARD THERAPY JETS: 4 IN SPA
POOL FINISH: MARCITE OR EQUAL
PIPING: SCH. 40 INLETS: POOL (4) SPA (21
DECK: PAVERS ELECTRIC: BY OTHERS
POOL LIGHT: (2) LED - NICHELESS
SPA LIGHT: ) LED - NICHELESS
LADDER: NO HANDRAIL: NO
PUMP: 2.7 HP JANDY E-PUMP - JEP2.OSVRS
A.P.S.P. PUMP CERT.: CURVE A - 35 GPM (a2 1730 RPM
FILTER: JANDI' CS250 CARTRIDGE
250 SQ. FT. FILTER AREA
HEATER: JANDY 400,000 BTU GAS HEATER W/
APPROVED COVER
VACUUM LINE: YES
POOL AREA: 468 S.F. PERIMETER 96 L.F.
SPA AREA: 140 S.F. PERIMETER 49 L.F.
AUTO -FILL: YES OVERFLOW: YES
CHLORINE GENERATOR: YES
POOL CONTROLLER SYSTEM: JANDY IAQUALINK
�I
w�
I
a M
O �
CJ
I•�
a0i O
� W
IYI/
�aq � O Or: J=
�w M * a:z
i C F- �:
,Z�y•;� Z In 4(
•
f00 M
O U
Ya
�
� a
00 a a
U
W
W�
aA
��
au
a
a �z
oa
Q
0
a
�a
O
N
O
DRAWN BY:
CLC
CHECKED BY:
WJC
DATE:
1-20-19
SCALE:
AS NOTED
JOB NUMBER:
19-119
SHEET
2 OF 2