HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR,BUILDING CONSTRUCTION Florida Department of Bus"s=q I egulation - Residential Performance Method i Project Name: ROBERSON•RESIDENtE lyi Ai v 8 Ji3 ilder Name. Street: I erma office: SCANNED - City, State. Zip:---PORTST.-LUCIE,FL,- SI-.Lucie-County,-Permitting- effrtNumber. - - - - - -BY -- - -- Owner. unsdicuon: St. Lucie Count Design Location: FL, Fort Pierce County: SL Lucie (Florida Climate Zone 2.) iI 1. New construction or existing Addition 9. WaOTypes(951:0 sgft.) Insulation Area •:�2. Single family or multiple family Single-family a. Frame -Wood, Exterior R=19.0 855.00 ft2 b. Frame -.Wood, Adjacent R=11.0 96.00.ft' 3. _Number of units, if multiple family 1 c. WA R= ft' 4. Number of Bedrooms(Bedrms,In Addition) 0(0) d. N/A R= ft' 5. Is this a worst case? No 10. Ceiling Types (602.0 sgft.) Insulation Area - - a. Under Attic (Vented) R=30.0 602.00 ft' 6. Conditioned floor area.. above grade (ft� 602 b. N/A R= ft' Conditioned.floor area below grade (W) 0. c. NIA R= ft i I- Ducts R ft' 7. Windows(12.0 sgft.) Description Area a. U-Factor. Dbl, U=0.65 12.ODfN SHGC: SHGC=0.30 b. U-Factor. WA ff: 12. Cooling systems kBturhr Efficiency SHGC: a. Central Unit 18:0. SEER:20.30 c. U-Factor. NIA IF SHGC: 13. Heating. systems kBtulhr Efficiency d. U-Factor•: NIA fts a.Electric Heat .Pump 18.0 HSPF:11.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft Area Weighted Average SHGC: 0.300 14.Hot water .systems - None required 8. Floor Types (602.0 sqft.) Insulation Area a. Cap:. WA a. Slab -On -Grade Edge insulation R=0.0. 602.00 W b. Conservation features EF: 0.000 -b. NIA R= I? c. N/A R= fe 15. Credits CF. Pstat Glass/Floor Area: 0.020 Total. Proposed Modified Loads: 12.12 PASS Total Baseline Loads: 17.43 �'l hereby certify that the plans and specifications covered by phis Review of the plans and F-tHE S;rA �O calculation are in compliance with the Florida Energy specifications covered by this 1W Code. calculation indicates compliance with the Florida Energy Code. PREP D Y: DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 r� = 0 " ,a a I herebycertify th rs buil ' ty g, a esigned, is in compliance Florida Statutes. with the Florida nergy C COD WE OWNER/AGE BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and.lnsulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). AMR 3/712019 1:20 PM EnergyGauge® USA Section•R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 IIUDI It CI ItlfinflAw nurrwr 10.,.-.,...... PROJECT Title: ROBERSON RESIDENCE Bedrooms: 0 Address Type: Street Address Building Type: User Conditioned Area: 602 Lot# Owner -Name: Total Stories: 1 BloddSubdiirision: # of Units: 1 Worst Case: No PlatBook Builder Name: Rotate Angle: 0 Street Permit Office: _ Cross._ Ventilation: No County: - St. Lucie — Jurisdiction: Family Type: Single-family Whole House Fan: No City, State, Zip: PORT ST. LUCIE , NewOristing: Addition Comment: CLIMATE Design,Coption Design Temp Int Design Temp Heating Design Daily Temp TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 s0 70 75 299 62 Low _ BLOCKS Number Name Area Volume - - - 1 Entire House 602 4816 SPACES Number -Name Area Volume Kitchen Occupants ,Bedrooms Infil ID Finished Cooled Heated 1 WORK AREA 170 1360 No 4 1 Yes Yes Yes 2 EXT. GARAGE 432 3456 No 5 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio WORKAREA 25 it 0 170 R' 0 1 0 2 Slab -On -Grade Edge Insulatio EXT. GARAGE 70 R 0 432 ft' _ 0 1 0 ROOF ' ✓ # Type Roof Gable Roof Solar SA Emiq Emitt Deck Pitch Materials Area Area Color Absor. Tested Tested-Insul. (deg) 1 Hip Composition shingles 634 f ? 0 IF Medium 0.6 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 602 ft2 N N 3012019 1:20 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4 0 N O G f0 tD- 0 t0 ID tDt0 fO. '. O O Co. o G o 6 o o 0 0 'd - o t1 E ,.ry N N N. N N _.. C i0ILL LL i n . to S � r• o o O'. o ac; £ •IL � o 0 0 0 0 0 o o . z � N v O G � +C y INn `� ci, Op N •� N � .N �, a E Y. . '.. C '•. A m. U CO m _ o g W W' uo m w y n,. E z �,.- too 0 0 0 0 0 0 € o f o Se a z H Lu a N a A m A N e� y •o v. M ,.a" C_ g m yY , Q N_ t� 1 O C y t7t 0 ZL U 30 t) 7 W O O 0 O O LL O � Y Y0.' In .K. fp, RY' K t s N,N O oo o 0 0 0 0 y v c'O d. M W n E E` E E E E E LL LLA LL� LL TV V rn v v' g'. a `o `o o `o: `o `o, `a m m •o v •d. •w •d 'o. �, E O 3 W m p M oo LL$ IL E T d. ' 0 3 0 w N In 0 P rr r C n C a cr C LL H UUO �' N QUO N Om mm mm mm mn An mm mm O O W LL o �?� om mm mm mm mr rn mm mm ZZZ m .- �i= ZEE Q W C7 01-6 mm� Yl M > 0 om mm m n N.o 000 a.� CO0 dl D IL o c W 0 N 3 �N+N+ � n. mm mm mm mm 0D momW LL th m O » Q r n� m o - hm-n N fwo fOQi C c'f W O D. u N' N U �-�i� m rn nr 22 -Mtm0 rL 5. U W H W ~ W w } W = ccc mm mg mm mmmm co nn mm y c c Z g w 2 15 JO F C y O m Sc `m v mm mm mm mm = x W LL mmm rn nn mm mm d Nn rn mmm mm m U) I q. I a N y � "' mo mm mm mm rm rr mm mm I F � �c c nm nn mm mw D n a m o N � j Z LLIL a d W �, IL N QR (L LU v U o � d y U VIiG -Dam-.Di D aai av m m w O w S a E ; m O o mmm �aa 0 v0 c c e m � m c U 2 2 O Y 0 O1 tV a M C C. Cl 5i c a Z N m N M 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: ROBERSON RESIDENCE Builder Name: Street Permit Office: City, State, Zip: PORT ST. LUCIE , FL. Permit Number. x Owner. Jurisdiction: Design Location: FL, Fort Pierce w x U COMPONENT_ AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable Insulation shall requirements The exterior thermal envelope contains a continuous air barrier. Breaks or joints in the air barrier shall be sealed. not be used as a sealing material. Ceilin /attic g The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. The insulation in any dropped lsoffit Access openings, dropdown stairsor knee wall doors to shall be aligned with the,air barrier. barrier. unconditioned attic spaces shall be sealed.. _ Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. -Knee walls shall be sealed. with a material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed insubstantial contact and - continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors (Including - The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to above -garage maintainpermanent contact with the underside of and cantilevered subfloor decking, or floor framing cavity insulation floors) .shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all, perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided insteadof floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be Permanently attached to the crawlspace • Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installationreadily conforms to the available cavity spaces. Garage separation .Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installedin the building thermal envelope Recessed light futures installed:inthe building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior wails, or insulation that on installation readily conforms to available space shall extend behind ninino and wiring. Exterior walls adjacent to showers and tubs shall Shower/tub on exterior wall The air barrier installed at exterior walls adjacent to showers and tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box oi The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots. HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition. inspection ha in aeenr� ,.dn, n 3/7/2019 1:20 PM EnergyGauge® USA FBG 6th Edition (2017)VCompliant Software Page 1 of 1 2017-EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 70. The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. Addition 12. Ducts, location & insulation level a) Supply ducts R 2. Single-family or multiple -family 2. Single-family b) Return duets R 3. No. of units (if multiple -family) 3. 1 c) AHU location 4. Number of bedrooms 4. 0 5. Is this a worst case? (yes/no) 5. No 6. Conditioned floor area (sq. ft.) 6. 602 7. Windows, type and area a) U-factor.(we(ghted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.300 - c) Area 7c. 12.0 8. Skylights a) U-factor.(weighted average) Be. NA b) Solar Heat Gain Coefficient{SHGC) 8b. NA 9. Floor type; insulation level: a) Slab -on -grade (R-value) 93. 0.0 b) Wood, raised (R-value) Sib. c) Concrete, raised (R-value) go. 10. Wall type and insulation: A. Exterior. 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 10A1. 19.0 10A2. 13. Cooling system: Capacity18.0 a) Split system SEER 20.3 b) Single package SEER c) Ground/water source SEERICOP - d) Room unif/PTAC EER e) Other 14. Heating system: Capacity 18.0 a) Split system heat pump HSPF 11.0 b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF b) Gas fired; natural gas EF C) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ t) Heat recovery unit HeatRec°/u g), Other 1061. 11.0 10B2. - 16. HVAC credits claimed (Performance Method) a) Ceiling fans Yes 11a. 30.0 b) Cross ventilation No 11 b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit t) Programmable thermostat Yes "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be ins ed,(or exceeded) in.this home before final inspection. Otherwise, a new EPL display card will be comp) ba installed code compliant features. e: J 21I I Builder Signature:_LC Dat7 1 (e( Address of New Home: Z30 L ZJ 14P4r.wCCk 1.1Q City/FL Zip: PORT ST. LUCIE. FL 317/2019 1:20:08 PM EnergyGaugeO USA 6.0,02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software. Page 1 of 1 Pro ect Summa Job: wrightsoft N Data: Entire House By. QUICK CALCS, INC. 317 ST.. LUCIE LANE, FORTPIERCE, FL34946 Phde:772466-6799 EmaTQUICJ(CALCS@AOL.COM Project• • For.-ROBERSON RESIDENCE PORT ST. LUCIE, FL r r_!`c_TX Ir=rl Notes: I MAR Q 8 1019 Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Insidedb 75 OF DesignTD 28 OF DesignTD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 7381 Btuh Structure 7606 Btuh Duds 1784 Btuh Duds 2339 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfln) 0 Btuh (gone) 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipmentload 9165 Btuh Use manufacturers data n Ratelswingg multipplier 0.95 Infiltration Equipmentsensibleload 9449 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3007 Btuh Ducts 650 Btuh " Central vent (0 cfm) 0 Btuh Heatingg • Coolingg (none) Area (fF) 602 602 Equipment latent load 3657 Btuh Volume (4') 5418 5418 Airchanges/hour 0.61 0.32 Equipment Total Load Sen+Lat) 13106 Btuh Equiv.AVF (cfin) 55 29 Req. total capacity at 0.70 SHR 1.1 ton Heating Equipment Summary Cooling Equipment Summary Make DIAKIN Make DIAKIN Trade Trade Model RXS18LVJU Cond RXS18LVJU AHRI ref 5265757 Coil FTXS18LVJU AHRI ref 5265757 Efficiency 11 HSPF Efficiency 12.7 EER, 20.3 SEER Heating input Sensiblecooling 12600 Btuh Heating output 18000 Btuh @47OF Latent cooling 5400 Btuh Temperature rise 28 OF Total cooling 18000 Btuh Actual air flow 580 cim Actual air flow 580 cfin Air flow factor 0.063 cfmBtuh Airflowfactor 0.058 cfmOuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.73 Capacity balance point = 26 OF Backup: Input=3kW, Oulput=10483Btuh, 100AFUE FILE copy Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrighisoft- 2019-Mar-071322:12 /dC�. v^^^^ RigtFS•uteGUtvem1201919.0.01 RSU06101 Page 1 _.o n6AWrigtbofiWACROBERSONRESIDENCEnp Cale=MJ6 Frort Doorfa NE wrightsoftRight-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phom:772A66-6799 Email: OUICKCALCS@AOL.COM 1 Roomname Entm Hale WORKAREA 2 E;Vowd%dI 95.0 it 25.0 it 3 Room height 9.0 It 9.0 It heatbzml 4 Room dmenslons 1.0 x 170.0 ft 5 Room area 602.0 ft' 170.0 ft' Ty Ccn&udon U-wlue Or HTM Area RR'�� Lwd number (Btuhy-`n (Stuh4P) or penmeeter (ft) (Btuh) or perimefer M (BWh) Heat Cool Gros N/P/S Heat Cool Gros NIP/9 Heat Coot 6 W 12E-0sv 0.068 In 1.90 1.18 36 36 69 43 0 0 A 0 ,W �— 0 12E-0sn 0.068 a 1.90 1.18 324 303 577 359 108 108 206 128 11130 0.390 a 10.92 10.34 21 21 229 217 0 0 0 0 W 12E-Clew 0.068 s 1.90 1.18 171 171 326 2D2 9 9 17 11 11 W, 12E-Ow 0.068 w 1.90 1.18 324 291 554 344 108 75 143 89 �LDG 4A5-2ob 0560 w 15.68 41.45 12 1 188 497 12 1 188 497 11DO 0.390 w 1092 1034 21 21 229 217 21 21 229 217 P 12C-O w 0.091 - 255 1.06 135 135 344 143 135 135 344 143 c 16830ad 0.032 - 090 1.60 602 602 539 963 170 170 152 272 F 27A-tpi 0.989 27.69 0.00 602 95 2831 '0 170 25 692 - 0 8 c)AEDevwson 275 275 Envelope losdgain 5686 32M 1972 1631 12 a) Infiltration 1695 476 446 125 b) Roomventilafion 0 0 0 0 13 hlarmlgains Oovpants@ 23D 9 2070 4 920 Appliencee/other 1800 900 Subbatal(lm,atito13) 7381 76M 2418 3577 Lesexemalload 0 0 0 0 Lestrensfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 7381 7606 2418 3577 15 Ductloads 240/6 31% 1784 2339 24% 31% 564 1100 Total room load 9165 9946 3002 4677 Airrequired(dm) 5B0 580 190 273 Calculations approved bVACCAto meet all requirements of Manual J 8th Ed -r k- wrighbo_ft' - 20194Mar-0713:22:12 . GA RtSON ESIDiversa1 p Calc.0.01 Fnon1I01 Page 1 ...owrerlslWdOtLsoflFNACV20BERSONRESIDENCEnp Cak=NUB Frort DoorYaces:NE ` wFightsoft- RighW@ Worksheet Job: Entire House Dato' QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772466.6799 Email: QUiCKCALCS@AOL.COM 1 Room name EXT. GARAGE 2 Exposed vell 70.0 ft 3 Room height 9.0 R heaftol 4 Room dimensions 24.0 x 18.0 it 5 Room area 432.0 R Ty ConstruQion U-Value Or HTM Ate Lead number (Btuhd2-°F) (BtuhAl) or perimeter (R) (Load h) or perimeter Heat Cool Grow NIP1S Heat Cool Coos N/P)S Heal Cool 6 W 12E4hw 0.068 n 1.90 1.18 36 36 "69 43 4N z 12E-Osv 0.068 a 1.90 1.18 216 195 371 231 . 11D0 0.390 a 10.92 10.34 21 21 229 217 W 12E-OW 0.068 s 1.90 1.18 162 162 308 192 11 12E-0av 0.068 w 1.90 1.18 216 216 411 256 4A5-2ob 0.560 w 15AB 41A5 0 0 0 0 11DO 0.390 w 10.92 10.34 0 0 0 0 P 12C-Ow 0.091 - 255 - -1.06 0 0 0 0 C 16B30ad 0.032 - 0.90 1.60 432 432 387 691 F 22A-to 0.989 - 27.69 0.00 432 70 1938 0 6 c)AEDemysion 0 Envelope los4gam 3714 1629 12 a) Infiltration 1249 351 b) Room Ventilation 0 0 13 Internalgains O=parrls@ 230 5 1150 Applianoeslother 900 Sublal(Iines6W13) 49W 40M Le 063malload 0 0 Lestransrer 0 0 Redistributon 0 0 14 Srbbial 4963 4030 15 Dudloads 240/. 310/0 1200 1239 Total room load 6163 1 6269 Airreglrired(dm) 390 307 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. ,�, wrigfr'isoR` 2019-Mar-0713:22:12 A RIgFONRESIDENCsa1p Calc.0.01 RSrort Do Paget ...aamerfs\Wd9rttoR HJAC�ROBERSON RESIDENCEnp Cab=MJe Frorl Doorfaces: NE