Loading...
HomeMy WebLinkAboutPRODUCT EVALUATION REPORTR W R W Building Consultants, Inc. RC�L-i�7E6'— BConsulting and Engineering Services for the Building Ind istry M A q U. 8 C P.O. Box 230 Valrico, FL 33595 Phune913.6599197 Florida Board ofPrafessional EoginmisCeNficale ofAutborizationNo.AT. Lucie County, Permitting Product Category Sub Category Manufacturer Product Name E`xteiiu`r`• Swinging Therma Tru Corporation 13Y - Fiber -Classic and SmoothStar 118 Industrial Drive Composite Edge Opaque Fiberglass Single Door Doors' - Assemblies Edgerton, OH 43517 St. Luc e County InswinglOutswing Phone 419.298.1740 "Impact* Scope. This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. for Thenna Tru Corporation based on Rule Chapter No. 61G203, Method 1 D of the State of Florida Product Approval, Department of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations. 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind bome debris protection this product complies with FBC Sections 1609.1.2 & R301.212 and does not require an impact resistant covering. This product meets missile level "D" and d includes Wind Zone 4 as defined in ASTM E1996 and FBC Sections 1609.1.22 & R3012.1.2.1. 4. For 2x stud framing construction. anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-20468.1 requite further engineering analysis by a licensed engineer or registered architect 6. Filler -Classic & Smooth -Star Door panels require the use of "J" part numbers and must be stained or painted within sir months of installation 7. See drawing FL-20468.1 for size and design pressure limitations. . SupportfngDocuments. 1. Test Report No. Test Standard Testing Laboratory Signed by ETC 01-741-10700.0 TAS 202-94 ETC Laboratories Wendell W. Haney, P.E. ETC 01-741-10702.0 TAS 202-94 ETC Laboratories Wendell W. Haney, P.E. TEL 01461612 ASTM E1886-05, E1996-09, E330-02 Testing Evaluation Leb.,lnc. V.K. Wright TEL 01460145 ASTM E1886-02, E1996-02, E330-02 Testing Evaluation Lab.,lnc Lyndon F. Schmidt, P.E. 2. Drawing No. Prepared by Signed & Sealed by No. FL-20468.1 RW Building Consultants, Inc. (CA#9813) Lyndon F. Schmidt, P.E. 3. Calculations Prepared by Signed & Sealed by Anchoring RW Building Consultants, Inc. (CA#9813) Lyndon F. Schmidt, P.E- 4. Quality Assurance Certificate of Participation issued by National Accreditation and Management Institute, certifying that Thenna Tru Corporation is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. Sheet 1 of 1 No '43409 E ®PA" >T STATE OF Lyndon F. Schmidt P.E. FL PE No. 43409 1202017 THERMAITRU® d DOORS rip Fiber -Classic,'& Smooth -Stare COMPOSITE EDGE OPAQUE FIBERGLASS SINGLE DOOR INSWING/OUTSWING "IMPACT" GENERAL NOTES 1. This product has been evaluated and Is in compgance with the bth Edition 120171 Porfda BugAng Code 1TBC) smIchwai requirements exdudmg the °I6gh Velocity Huaicane Zone 1HVH11. 2. Product anchors stag be as fisted and spaced as shorn on details.Anchor embedment to base matedd shag be beyond wall dressing or stucco. 3. When used in areasneq,,,q wud bome deem protection this product complies With FBCSectam 1609.1.2 & R301212 and does not require an impact resistant covemg.Thts product meets ms•Ae level-W and includes Word Zoe 4 as defined inASTM E1996 and FBC Sections 16D9.124 & R3012121. 4. For 2cstud framing comfisnaDrt anchoring of these units shag be the same as that shown for2r buck mosorryconstruction. S. She conditions that deviate from the details of this drawing require fudher engineering analysis by fcensed engfneerwregistened architect. 6. FIberLiossfc BSmooMtorDoor pan& mgt&e the use of'P pad numbers and must be stained apatnted within s& months of Insttaffaffon. FABLE OF CONTENTS SNEN DF3CROTON i TYPiW6evatam.Deggnfttt &Gen Notm 2 Door PaIdDetags 3 Eow d ntolSVedicd Cross Secliw¢ 9%Buekl 5 N &Vavwcw5ecRons llR Bu d Namn &Vedicol Cms:Secfiam DJect to 7 V IQossSectlom ds 8 &Forme Anchanrg 9 Hadwae Defals to Components If smdMofedom a- 37.75-MAX OA FFRAME WIDTH DESIGN PRESSURE (PSI) DESIGN PRESSURE(PSF) CONFIGURATIONLOCI' INSWING OUTSWING HARDWARE POSITNE NEGATIVE POSITIVE NEGATNE X Latch & Deadbolf +67.0 -67.0 +67.0 -67.0 X MuDlpoint 1 +50.0 -50.0 +50.0 -50.0 See Sheet 3 for Hardware Specifications W. FL-2046B.1 1' EXTERIOR 1.198' �I.I t--Ib7S I ray COMPOSITE CAP '.. COMPOSITE INTERIORLOCKBLOGK ED CAP HMGESIBE (IZS LONG LVL) (ENGINEERED WOOD) (ENGINEERED WOOD) 1 HORIZONTAL CROSS SECTION 2 36D'MAX 35D13'MAX DOOR �PAN9 WIDTH F PAN�EI. N70TN� 2 � 2 S2 N o x $ X O T3� I DOOR PANEL DOOR PANG � BOOK 41 1Nbritl fbu h 0 0 M. POSITE AP TE80R Lk 0w x � •• CAP (ENGINEERED WOOD) (1ZSLONGWOOD) IENGINEERFOWOODI ff1 HORZONTAL CROSS SECTION 35813' MAX. DOOR �PANEL WIDTH 4 2 42 DOOR PANEL UT o� tt TOP RAIL 0 (COMPOSTIFIENGMEERED W000) G •F' m ¢I o � FOAM CORE (POLYURETHANE- lA PCF MM.1 INTERIOR EXTERIOR INTERIOR DMOR c � O� f �P Q Fi86tGUSSSKM II —BOTTOM RAIL II �IJP-- (COMP.) I--1JP_� %1 VERTICAL CROSS SECHON (VERTICAL CROSS SECTIONCROSS SECTION 2 $ FL-20I, o - ... of F HARDWgRETgBLE , MANUFACTURER MODEL - SCHLAGE KNOB: F51 DEADBOLC 060 KNOB: SIGNATURE SERIES KWIKSEf DEADSOLT: SIGNATURE SERIES (980) HOPPE MULDPOWT: MPDGART MM MA-TRU) (3pt.ManualTongue) 711111 illy illlll_i IIIIIII EMM, Fiber-Classic/Smooth-Star Door Pane) Options Products approved include all embossed panel doors and 2 panel recessed panel doors. Similar opaque panel configurations are allowed. Panels shown are for illustration and are representative only. mice% ltS ommxo xm: Fl.—zoasar itG B10ienu\memwiru PFRMANENI\A-FbAtle ProtluttApprovnls\iL-3N69 WBDR TT FC 55MWtt-Comp°sile\C-MMhgs\(l] 0(2017J-CUMENI\GL-2 11.3E44.1 Z O a N � 5Q e- Cl) m a N A � g � • �. T b N a_ 0 -• q3i� EEy-'6� a Ili n v O ^O z � O ° A RR 1-1/4•MIN. EMB. RYP.1 N :O IN in E3 ON1ys N v' 9 • ZE �q o . i F SCNIt,�� NO.43409 11/29/177 i = pp ZnI PRODUCT: IuwumamF P,h.l Byi BTAl9Op ' -'�.,.pNAL THERMS—TRU FlBERCL455 DOOR PZ N r. 9ehg �i0M0A P.E. No. 4J108 y \ LDQI(�BUILOINO CONSULTANiS.fI)lN llt Utt ✓I�(/�/ 2 it f3 V RECESSED PANEL NOTATION JK PART OF A59EMBLY: 1 ] 1] 1] UPDATE TO 6M EO 2017 MG JK y A w HORIZONTAL & VERTICAL P.O. Box 230. Voleco. M 03595 N0. DATE CROSS SECTIONS (2K BUCK) PNon• Nc.: B13.659.9197 1',,E CA No. 9813 EVIS NS O 901 B w.W. ewiomo Cownuv�uee we. ) | • . .o ; . f* -» : ; ■W� . @ A«:■ IX BuckK� ^ ®°\ / / g@ aan { 7 , z _e I�Ma /I � _m_,SECTION / y ^ . ` « � . �/` \i . 7 . e : NTMORz INTMR a / : §§ , \ ! a , _ � � ' \� _ „ 2 , , MP.)29 _[TY.�2{ r2 \xz_c__a �3 __CROSS ECTIa FL-Sm} is MAIL IXIERIOR VERTICAL CROSS CROSS SEMON�CROSS SECTION 6 Stwvm Directfo Mosorvy Oulrwing oNyw/4-9/16 (mnb DIRECTTO MASONRY MAK DESIGN PRESSURE w/STANDARD STRRU== ±55 PSF w/SECURITYSTRIKE= t65PSF n pop�13welj ,11 FA I-1/C MIN. FMB.(TYP.) 1-1/CHIN. EMB. (fYP.1 E @gMOR E �21 HORZONTAL CROSS SECTION ( 3'HORIZOWAL CROSS SECHON d Shown D'Rect to Mm'orvy 6 Shown D6ectlo Masonry Ou1sxNlg onryw/49/16 jamb Ouhwing ontyw/49/16 jaalb 1-11 BAP b HORIZONTAL CROSS SECTION d Shown West to Maso' Outzft onNw/ 69/16 bmb E%IBtIOR J'///////�1 INlprypR �VERHCAL CROSS SECRON�/UCACA`L CROSS SECRONN d SW� 99oW./6.9/)6j mb =try'# gE=y 1.S MAX :sYe. . vAe.11rY.1 ruc N.TS. �61HORIZONTALCROSS SECTION RRLBI: JK 6 Shown DBoCt to Mar moc en US n OuWngoNyw/69/ gI wnb FL-20466.1 mez•.r 6 orb G Notes: I. Sit Item 0's17.18,U34.35.36,37.383,39areatfoched to lambs w/(3)# 2-117pfhsaevrs at each end. SM Item RS Ib & 33 are attached fojanbs w/ (2( A8 %2-VY pih screws at each end. SA Item 5156 aNached tolambs ufifafrg (2) FIO X 2pph SMS of each end. .P-Mllwrliw SEE NOTE I E 4 A \ 4r+ n. • 1 VERTICAL CROSS SECTION .. Insw'ugso EXTERIOR INTERIOR EXTERIOR �1 VERTICAL CROSS SECTION 7 OrMMgSit INTERIOR SEE NOTE 1 EXTERIOR ERTICAL CRQS_S SECTION huwirg Sa INTERIOR SEE NOTE 1 O %41 VERTICAL CROSS SECTION 7 PUWCAxessSla 4ua=`O` � m^ Oj . o m Z c o nmi aN� y imzd E °w 562a. u mdc� o` i SO N 0 �2 ox OO UW 1� } Jx¢x CIS � Go o „ 301F, FL-2046B.1 °n u 7 o ii 9 Ct08 'aN YO 3d0d v«I 5 D az«wmvwoo awavna •m•6 v�os L6t8'BBB'Cl0'oN ouo4d ,1 BBaCc V 'ov IM NW COB '0'd A/I_ ONIQ11f10-�uy DN180NONV Ale l,3 NON9 -A'IBN36SV 8018tld p ^ g AB 3 D gr oad uoz as wa of dlVadn a Ll [ Nn OLLV10N l3NVd ¢3aa3J3N Ll l tl Z Ilt�flf�`�'B1NV1ln6N0.� = g aDnal—V{5L3{�IleN N``�,61Nojy'.'/'''ice 1oIwV�S�'!vu Pu.ci gg tv dO0A08 ✓B ov�ceud a -Ionaoud S LUdZ ll B0M ON .! ' k........... f S .�•% N 5 O� Or � tf 0 U x o _ z `e Z ku --{ NJ,# ('d.LLl'0'O I--� �xvw.,el U • d U. a m N I'dAl).4 y..�.�I•dd'0.0 'XVW.9t a � H a o � m N . u 25 0 [9'6�W'f-t'89NIZ-b�1N3NtlID-iLIBU eveazii�sCulw+a-�lau��J-nodwn�lllnaex e9wz+lilAeeobarnw�u am+w-Mw3Nrwa3a nu ew,auwumlti vMl vlNvalneuop v inB 'M'tl 9111E £b9B -9N -N ..Id i LBlB'BQQ'C LB - .1.1 .1,1 A8 31tl ON b �- QBQCf V 'oaUloA •pCZ soO '0'd 51iN%30 3aNM0aVN Nf >fl1 L{OZ Q3 4i9 O1 3lYpoll L{ Ll L L Vi ``i,iqiilll *dLS1N =SNOO ONIOIIIIOdiu� A QW35 Nr O"'N UWd 035S303a L{ 4{ l{ Z _ ``Q+VpWOiYs � ipt-4-S 'd auoP-Ri a0na1SV YN3 lei homes . de MW-d 4uewneop '1Of100ad /6Z/11 609e0'QN •• ?eMdpr.•i� ��` � � � C F� o " � u GS'I it SaSY'1 'd ® 1G i]ryry OE 25_• �j°, m ? rG : 0 BWVf dO NCO(3014SAWLn at' = doiwoads11 fdAil.9L'6Zscea ewvr do NOOO N009 ,. doi Woad SCI l I'da.9r6Z N �o rQr� N O S s t o 00 � W r+� gog .. 5S5 i_ o o �0 :E o f g m CD m =o 5V o � x 0 i'6'Bm0'Ct'8960L-HUN3tlWU-fL[B2) 6960E V\sLwmvp ->\WRodwo>-Uadw155>!1L tlWM 8960A1d161e!wAEtr gnpoy epygd-MN13NVWtl3d /ALL ew+eVL\4ual[ilM *=aG-2Ml-=OS'MD �Cft.' sa WIT 9= —Me-MMH=tsw I 5.75- GT'M ID �1' *L=S..r.'dQ 53 7S -gam a 6Nm sow 456 SBT *L=--Cr aUsSO 577' [-4W al o o . . . . . . . . . . . . . . Ur 2 [- 5.75 T 15 PURUCACCESPHRMOLD L.08 02 i f[R7TS. ).79M JK 2W _LFS F-204M.1 BILL OF MATERIALS BILL OF MATERIALS REM DESCRMN MATERIAL nEM# DESCRIPTION MATERIAL A 1XBUCK(SG>=0.42) WOOD 25 #8x2-1/2'PFH WOOD SCREW STEEL B 2XBUCK(SG >=0.421 WOOD 26 #8x5/8"PFH WOOD SCREW STEEL C 1/4" MAX. SHIM SPACE 27 LATCH STRIKE PLATE STEEL D 1 /4" X 23/4" PFH ELCO OR ITW CONCRETE SCREW STEEL 28 DEADBOLT STRIKE PLATE (STANDARD) STEEL E MASONRY - 3,OOD PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE 28A DEADBOLT SUB STRIKE PLATE STEEL 28B DEADBOLT STRIKE PLATE (SECURITY) STEEL G 3/16" X 3-1 /4" ITW CONCRETE SCREW STEEL 29 4" X 4" HINGE STEEL J 1/4"X33/4" PFH ELCO OR ITW CONCRETE SCREW STEEL 30 LATCH& DEADBOLT STRIKE PLATE (TONGUE SYSTEM) ALUM/COMP L #10 X2-1/Z'PFH WOOD SCREW (I.I 5'MIN. EMBEDMENT) STEEL 31 MULTIP01NT STRIKE PLATE (TONGUE SYSTEM) AWWCOMP M 3/16"X2-1/4" ITW CONCRETE SCREW STEEL 32 INSWING THRESHOLD ALUM/COMP N 3/16"X23/4"ITW CONCRETE SCREW STEEL 33 INSWING THRESHOLD ALUM/COMP 1 JAMB (FINGER JOINT PINE) WOOD 34 INSWING THRESHOLD ALUM/COMP 6 WEATHERSTRIP '(MEDIUM REACH) FOAM 35 INSWING THRESHOLD ALUM/COMP 7 WEATHERSTRIP'(LONG REACH) FOAM 36 INSWING THRESHOLD ALUM/COMP 8 SWEEP - VINYL 37 INSWING THRESHOLD ALUM/COMP 9 SWEEP (USE W/; MODERATE CLIMATE THRESHOLD) VINYL 38 INSWING THRESHOLD ALUM/COMP 10 SWEEP (USE W/ PUBLIC ACCESS THRESHOLD) VINYL 39 INSWING THRESHOLD ALUM/COMP 15 PUBLIC ACCESS THRESHOLD ALUM 40 DOOR PANEL (BOOK) - 16 OUTSWING THRESHOLD ALUM/COMP 41 DOOR PANEL (HYBRID) 17 OUTSWING THRESHOLD ALUM/COMP 1 42 DOOR PANEL(UI) 18 OUTSWING THRESHOLD ALUM/COMP 22 #8 x 3/4" PFH WOOD SCREW STEEL 23 #10x3/4"PFH WOOD SCREW STEEL 24 #10 x I" PFH WOOD SCREW STEEL CONCREEANCHOR NOTES: 1. Concrete anchor locations at the comers maybe adjusted to maintain Rse min edge distance to nwrtarjoints. 2. Concrete anchorlocatiomnoted as "MAX. ON CENTW must be adjusted to mamfain the mh edge dMance to mortorlotnts, addtlionai co=ete anchors may be required to ensure Me °MAIL ON CENTER" dmenstan ara not exceeded 3. Concrefeanchorfabie: z' ANCHOR ANCHOR MIN MIN•CLEARANCE' MIN+:CLEARANCE TYPE StEE EMBEDMENT TOMASONRY TDAWACENT -EDGE Z;'ANCHOR TAPCON ELCO 1. ULTRACON TAPC RON0ZI AS SHOWN 1.1/T WOOD SCREW INSTALLATION NOTES: 1. Maintain a minimum 5/8"edge distance, I" end distance, & 1"o.c. spacing of wood screws to prevent the splitting of wood. Nib K �o �o i c N s A m FL-20466.1 I a