Loading...
HomeMy WebLinkAboutEVALUATION REPORTy v3 �olDE AdOD DI Ic ':D FASTENERS OR ATTACHMENTS ST. LUCIE COUNTY BUILD I G DI ISION iPRE THE RESPONSIBILITY OF THE REVIEWED FOR COMPLIAVE REVIEWED BY CONTRACTOR Of RECORD. u DATE PLA SAND PERMIT MUS E KEPT ON ]QB EXTERIOR RESEARCH &DESIGN, U.C. IS7-TRINITYIERD R Nd INSPECTION(S) WILL BE MADE Certificate of Authorization #9503 353 Christian street, unit 13 THESE PLANS AND ALL PROPOSED WORK Oxford, CT 06478 ARESUEJECTTO ANY CORRECTIONS (203) 262-9245 EVALUATION REPORT REQUIRED BY FIELD INSPECTORS THAT Tarco Roofing MAY 8E NECESSARY IN ORDER TO Evaluation Report T37910.06.11-R4 One Information Way, Suite 225 COMPLY WITH ALL APPLICABLE CODES. FL14672-R4 Little Rock, AR 72202 Date of Issuance: 06/23/2011 Revision 4:10/02/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E..for use of .the product under the_Florida.Building.Code. The product described herein has been.evaluat fodNNED compliance with the Gbh Edition (2017) Florida Building Code sections noted herein. BY DESCRIpT1oN: LeakBarrierO EasyTorchTM Modified Bitumen Roof Systems St. Lucie County LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation. changes, or.provisions of the Code.that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TRINI1yl ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INspEcTicim Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors andshall be available for inspection at thejob site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus a 4-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The rechmik ualappearingms eutheravi by 110 en Nkminen, P.E. en1D/TQAQ17. m"¢ data notserve az an ekrnonkalNsigned d.nc CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, U.C. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLG d/b/a Trin[ty]ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, RE. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. '\-,,,/\TRINITY I ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems Compliance Statement: LeakBarrier® EasyTorch^ Modified Bitumen Roof Systems, as produced by Tamo Roofing, have demonstrated compliance with the following sections of the 616 Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. 'STANDARDS: Section Property Standard Year 1504.3.1 Wind FM 4474 2011 1504.7 Impact FM 4470 2012 1507.10.2 Physical Properties ASTM D226 2009 1507.10.2 Physical Properties ASTM D4601 2012 1507.11.2 Physical Properties ASTM D6163 2008 1507.11.2 Physical Properties ASTM D6222 2011 3. REFERENCES: Entity Examination Reference Date ERD(TST6049) Wind - FM4470/4474 T36510.05.11 05/12/2011 ERD (TST6049) Physical Properties T35450.06.11 06/22/2011 ERD(TST6049) FM4470 T39050.11.11 11/18/2011 ERD(TST6D49) Physical Properties T39040.11.11 11/21/2011 ERD(TST6D49) Wind - FM4470/4474 K39690SC 03/07/2012 ERD(TST6049) Wind - FM4470/4474 TAR-SC7960.01.16 O1/31/2016 ERD(TSr6049) Wind - FM4470/4474 TAR-SC5670.03.16 03/21/2016 ERD(TST6049) Wind - FM4470/4474 T6460.06.07-R2 05/26/2017 ERD(TST6049) Physical Properties T6470.08.07-R2 06/02/2017 UL(QUA1743) Quality Assurance Service Confirmation Exp.03/09/2020 4. PRODUCT DESCRIPTION: This Evaluation Report covers LeakBarrier® EasyTomh^ Modified Bitumen Roof Systems installed in accordance WithTarco Roofing published installation instructions and the Limitations / Conditions of Use herein. The following products make up the subject systems. Table 1:,Roll-Goods for LeakBarrier®-EasyTorchTm Modified Bitumen Roof Systems Type Product Specification Reference Type Grade Base Sheets: LeakBarrier• EasyLay" ASTM D226 It N/A LeakBarrier° EasyNailBase^' ASTM D4601 rruaruneel II N/A Smooth Surfaced Membranes: LeakBarrier• EasyTorch" SA Base ASTM D6163 I S LeakBarrier• EasyTorch"' APP Smooth ASTM D6222 I S Granule Surfaced Membranes: LeakBarrier• EasyTorchm APP Granular ASTM D6222 I G Ederior Research and Design, LLC. Evaluation Report737930.06.11-R4 Cemifxata ofAodwnradon N9503 eEOmON(2017)FBC NON-HVHZ EVALUATION FL14672-R4 IeakBardera Easyromh Modified Bitumen Roof Systems Revision 4: 10/02/2017 Page 2 of 4 `JTRINI Y(ERD 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity(ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire classification does not form part of this Evaluation Report, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC2603.4 unless the exceptions stated in-FBC 2603.4.1 and 2603.6apply. 5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511. 5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure for theselectedassembly shall -meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD3, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.20.1 of FM Loss Prevention Data Sheet 1-29 (January 2O16) for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 26. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E9O7, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded Insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61620-3. 6. INSTALLATION: 6.1 EasyTorchm Modified Bitumen Roof Systems shall be installed in accordance with Tarco Roofing published installation instructions, subject to the Limitations / Conditions of Use noted herein. Exterior Research and Design, LLC. Evaluation Report T37910.06.11-R4 Cemrf oJAuMorixodon N9543 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL14672-114 LeaABamer^ EasyTorch Modified Bitumen Roof Systems Revision4: 10/02/2017 Page 3 of 4 rTRINITY I ERD 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: Underwriters Laboratories—QUA1743; (414) 248-6409; Karen.buchmann@us.ul.com THE FOUR (4) PAGES THAT FOLLOWS FORM PART OF THIS EVALUATION REPORT - Exterior Research and Design, U.C. Evaluation ReportT37910.06.11-R4 Cemftm of Auftrication"543 6'"EDMON(2017)FBC NON-HVHZ EVALUATION FL34672-R4 IeakBarrier' Easyforch Modified Bitumen Roof Systems Revision 4. 10/02/2017 Page4 of 4 `�.I I KINITY ERD TABLE SA WOOD DECKS —NEW CONSTRUCTION, RERODF(Tear-Off)orRECOVER ,' r SYSLEMTYPEC:-MECHANICALLY ATTACNEDINSULATION BONDE6ii00F`C6VEfi+ System Deck Top'Insulatlon layer Roof Cover MDP No. (Note 1) Base Insulation layer ji (PSO Type Fasteners Attach Base Ply Ply Cap SELF-ADHENNG BASE PLY: .(i� ,. < Min.IS/32" (Optional)Oneormore Min. 3/8-inch SECUROCK EasyTorch SA Base, (Optional) EasyTorch SA Base, EasyTorch APP Smooth W-1. plywood atmax. layers, any combination, Gypsum -Fiber Roof Board Note 2 1 per 1 ftz self -adhering self -adhering or EasyTorch APP or Granular, torch- -52.5 24":spans loose laid Smooth, torch -applied applied Min. 15/32" (Optional) One or more ( P ) Min. 2-Inch ACFoam 11, EnergyGuard Polyiso, ENRGY EasyTorch SA Base, (Optional) EasyTorch SA Base, EasyTorch APP Smooth W2. plywood at maz. layers, any combination, 3,H-Shield, ISO 95+GL or Note Sperl ftr self -adhering self -adhering or EasyTorch APP or Granular, torch- -82.5 24"'spans Iooselaid Multi -Max FA3 Smooth, to rchapplied applied TDkHAFPUED BASE PLY: -; `-. < , .. ,:. '. -`: •:` ' Min. 15/32" (Optional) One or more Min. 3/8-Inch SECUROCK r EasyTorch APP (Optional) EasyTorch APP EasyTorch APP Smooth W-3. plywood at max. layers, anycombination, Gypsum -Fiber Roof Board Nate 2 1 per 3 k Smooth, torch- Smooth, torch -applied or Granular, torch- -52.5 24" loose laid applied applied TABLE 119: WOOD DECKS- NEW CONSTRUCTION, REROOF,(Tear-Off)or RECOVER, ' -` SYSTEM TYPED: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER' System Deck Insulation Layer Base Sheet Roof Cover MDP No, (Note 1) Type Attach Type Fasteners Attach Base Ply Ply Cap Ply (Psf) SEU-AD"mons BASE PLY: = Min, 15/32" Any type, Loose 10-Inch o.c. In the min. 4-inch lap and EasyTorch SA (Optional) EasyTorch SA Base, EasyTorch APP W-4, plywood at max. thickness or laid Easylay Note 30-Inch o,c, in two, equally spaced, Base, self- self -adhering or EasyTorch Smooth or Granular, -60.0 24"spans combination staggered center rows adhering APP Smooth, torch -applied torch -applied Min. 15/32" Any type, [nose 8-inch o.c. In the min. 4-inch lap and EasyTorch SA (Optional) EasyTorch SA Base, EasyTorch APP W.S. plywood at max. thickness or laid Easylay Note 8-inch o.c. in four(4), equally spaced, Base, Self- self -adhering or EasyTorch Smooth or Granular, -135.0 24"spans combination staggered center rows adhering APP Smooth, torch -applied torch -applied Min. 15/32" Any type, Loose 6-Inch o.c. in the min. flinch lap and EasyTorch SA (Optional) EasyTorch SA Base, EasyTorch APP W-6. plywood at max. thickness or laid EasyNailBase Note 6-inch o.c. in four(4), equally spaced, Base, self- self -adhering or EasyTorch Smooth or Granular, -135.0 24"spans combination staggered center rows adhering APP Smooth, torch -applied torch -applied TORCH,APPDED BASE PLY:, Min. 15/32" Any type, Loose 6-inch o.c. in the min. 4-inch lap and EasyTorch APP (Optional) EasyTorch APP EasyTorch APP W-7. plywood at max. thickness or laid EasyNailBase Note2 &Inch o.c. in four(4), equally spaced, Smooth, torch- Smooth, torch -applied Smooth or Granular, -135.0 24"spans combination staggered center rows applied torch -applied Exterior Research and Design, U.C. d/h/a Trinhy(ERD Evaluation Report T37910.06.31-R4 for FL14672-R4 ( rtf)imte ofAuthorizadon#950 67"EDITI0N(2017)FBC NON-HVHZ EVALUATION Revision 4: 10/02/2017 Prepared by: Robert Nieminen, PE-59166 LeakBarrlere EasyTorch"' Modified Bitumen Roof Systems, (254) 913.7750 Appendix 1, Page 2 of 'l TRINITY( ERD h APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESIsrANCE - ` +.- r �, .0 Table Deck Application Type Description Page 1A Wood New, Reroof (Fear -Off) or Recover C Mach. Attached Insulation, Bonded Roof Cover 2 1B Wood New, Reroof (Tear -Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 2 1071 Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 3 1C-2 Wood New, Reroof (Tear -Oft) or Recover E Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 4 SD Wood New or Remof(Tear-Off) F Non -Insulated, Bonded Roof Cover 4 2A Concrete New or Remof(Tear-Oft) F Non -Insulated, Bonded Roof Cover 4 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck root components. Roof decks and structural members shall be In accordancewith FBC requirements to the satisfaction of the Authority Having Jurisdiction, Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be ofsufficient length for the following engagements: ➢ Wood Deck: OMG #12 or #14 HD with OMG 3 in. Galvalume Steel Plate (non -ribbed) or Tru-fast DP or HD with Trufast 3" Metal Insulation Plates. Minimum %-Inch plywood penetration or minimum 1-Inch wood plank embedment 3. Unless otherwise noted, insulation may be any one layer or combination of potylsocyanurate, polystyrene, wood fiberboard, partite or g/psum-based roof board that meets the CA requirements of F.A.C. Rule 61G20- 3 and is documented as meeting FBC 1505,1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1.29 (January 2016) for Zone 2/3 enhancements, S. For assemblies where all components are fully adhered, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis Is permitted. 6. For mechanically attached components over existing decks, fasteners shall beytested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Stanard TAS 105. 7. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing root system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ANSI/SPRI W-1, ASTM E907, FM Lass Prevention Data Sheet 1.52 or Testing Application Standard TAS 124. S. "MDP"m Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design, LLC. d/b/a Trinity lERD Evaluation Report T37910.06.11-R4 for FL14672-R4 Certo7cate of Authorization n950 eH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 10/02/2017 Prepared by: Robert Nieminen, PE-59166 LeakBarriere Easyrorchm Modified Bitumen Roof Systems, (254) 913-7750 Appendix 1, Page 1 of 4 '`J TRINITY ERD TABLE 1C-1: WOOD DECKS -NEW CONSTRUCTION or.REROOF (Tar -off) ,, M -t :. • r ,i , - ' MECHANICALLY ATTACHED BASESHEET (nails), BONDED ROOF COVER SYSTEM TYPE E: NON -INSULATED, MOP System Deck Base Sheet Base Ply Roof Cover Pty Cap Ply lPa� No. (Note 1) Type Fasteners Attach - 1 M „ SEIF-ADHERING BASE PLY: Min.19/32" 128a, annular ring shank nails 7-Inch o.c.vinthe4-inc:Tapnd 7- EasyTorch SA Base, .n l) self-adherin or Eas Torch APP self(op-a hexing orrisTorch DrchA, EasyTorch APP Smooth or Granular, -60.0W-8, plywood at max. Easytay and min. 32 ga., 1-5/8' diameter Inchoc. in three equaced, self -adhering Smooth, torch -applied torch -applied 24":spans tin -caps. (Ref. FBC1517.5) staggered center row 8-Inch in the min.4-inch lap and (Optional) EasyTorch SA Base, EasyTorch APP Min. 35/32" o.c. 8-Inch o.c. in four (4), equally EasyTorch SA Base, self -adhering or EasyTorch APP Smooth or Granular, -82.5 W-9. plywood at max. Easylay Simplex MAXX Cap Fastener spaced, staggered center rows self -adhering Smooth, torch -applied torch -applied 24" spans Min. 15/32" 12 ga, annular ringshank nails 4-Inch o.c. in the 4-inch lap and 4- EasyTorch SA Base, (Optional) EasyTorch SA Base, self -adhering or EasyTorch APP EasyTorch APP Smooth or Granular, -120.0 W-10. plywood at max. EasyWy and min. 32 ga., diameter Inch o.c. in four equally spaced, self -adhering Smooth, torch -applied torch -applied 24" spans BC 1'5 tin-wps. (Ref. FBC 151 r r staggered center rows (Optional) EasyTorch SA Base, EasyTorch APP Min. 15{32" k n 12 Be. annular rin shank nails 6 4-Inch o.c. in the 4-Inch lap and 4- Inch in five(5), equally spaced, EasyTorch SA Base, self-adheringor EasyTorch APP Smooth or Granular, -120.0 W-11. plywood at max. EasyNailBase and min. 32 ga., 1-5/8"diameter o.c. self -adhering Smooth, torch -applied torch -applied 24'^spans tin -caps. (Ref. FBC1517.5) - staggered center rows TORW-APPDEDBASEPLY: Min. 15/32" " i. - 9-inch o.c in the min. 2-Inch lap and (Optional) EasyTorch •. ..- (Optional) EasyTorch APP EasyTorch APP Smooth or Granular, .45.0• W-12. plywood at max. EasyNailBase Simplex MAXX Cap Fastener I8-Inch o.c in two (2), equally APP Smooth, torch- applied Smooth, torch -applied torch -applied 24"spans spaced, staggered center rows EasyTorch APP Min. 15/32" 9-inch o.c. in the min. 2-Inch lap and (Optional) EasyTorch (Optional) EasyTorch APP Smooth or Granular, -52.5 W-13. plywood at max. EasyNailBase XX Simplex MACap Fastener 12-Inch mc. in two (2), equally APP Smooth, torch- applied Smooth, torch -applied torch -applied 24"spans spaced, staggered center rows 6-inch o.c. in the min. 2-Inch lap and (Optional) EasyTorch (Optional) EasyTorch APP EasyTorch APP Smooth or Granular, -90.0 W-14, Min. SSJ32" plywood at max. EasyNailBase Simplex MAXX Cap Fastener 6-Inch o.c. in two (2), equally APP Smooth, torch- Smooth, torch -applied torch -applied 24".spans spaced, staggered center rows applied EasyTorch APP Min. 15/32" 64nch o.c. in the min. 2-inch lap and (Optional) EasyTorch (Optional) EasyTorch APP Smooth or Granular, -305.0 W-15. plywood at max. EasyNailBase Simplex MAXX Cap Fastener 6-Inch o.c. in three (3), equally APP Smooth, torch- applied Smooth, torch -applied torch -applied 24"spans spaced, staggered center rows EasyTorch APP 15/32" 12 ga. annular ringshank nails 4-Inch o.c. In the 4-inch la and 4- p (optional) EasyTorch (OP - ) (Optional) EasyTorch APP Smooth or Granular, -120.0 W-16. plywood at max. EasyNailBase and min. 32 ga., 1-5/8" diameter Inch o.c. in five (5), equally spaced, APP Smooth, torch- applied Smooth, torch -applied torch -applied 24"spans tin -caps. (Ref. FBC 1517.5) staggered center rows Evaluation Report T37910.06.11-R4 for FL14672-R4 Exterior Research and Design, LLC. d/b/a Trinity IERD Revision 4: 10/02/2017 CerrPcate ofAuthodzatlon 09503 6r" EDITION (2017) FBC NON-HVH2 EVALUATION Appendix 1, Page 3 of 4 Prepared by: Robert Nieminen, PE-59166 LeakBarrler° EasyTorch'" Modified Bitumen Roof systems, (254) 913.7750 FA , I R NIIY I ERD TABLE SC2,'WOOD DECKS -NEW CONSTRUCTION, REROOF.(Tear-Off)orVCOVEFI SYSTEM TYPE-E: NOWINSULATED, MECHANICACLN ATTACHED;BASE SHEET ("screws &plates), BONDED Cf00F COVER` System Deck Base Sheet i Roof Cover MOP No. (Note 1) Type Fasteners Attach Base Ply Ply Cap ply (pso SEIFADNERING BASE PLY: -. .- •. "' _ .. - _ _. -. ; W-17. Min. 15/32" plywood at max. Easylay Note 30-Inch o.c. in the min, 4-Inch lap and 10-inch o.c. in two, EasyTorch SA Base, (Optional) EasyTorch SA Base, self -adhering or EasyTorch APP EasyTorch APP Smooth or Granular, -60.0 24"spans equally spaced, staggered center rows self -adhering Smooth, torch -applied torch -applied W-1g, Min. 15/32" plywood at max. Easylay Note2 8-inch o.c.in 8-inch o.c, in the min. flinch lap and 8-inch o.c. in four (4), EasyTorch SA Base, (Optional) EasyTorch SA Base, self -adhering or EasyTorch APP EasyTorch APP Smooth or Granular, -135.0 24" spans ered center rows self -adhering Smooth, torch -applied torch -applied W-19. Min. 15/32" plywood at max. EasyNallBase Note .. . 6-inch ocin the min4-Inch lap and Finch o.c. in four (4j, EasyTorch SA Base, (Optional) EasyTorch SA Base, self -adhering or EasyTorch APP EasyTorch APP Smooth or Granular, -135.0 24"spans equally spaced, staggered center rows self -adhering Smooth, torch -applied torch -applied TDROf-APPDED BASE Pp: W-20, Min. 15/32" plywood at max. EasyNallBase Note 2 6-inch o.c. in the min. 4-inch lap and 6-Inch o.c, in four (4), (Optional) EasyTorch APP Sr torch- (motional) EasyTorch APP EasyTorch APP Smooth or Granular, -135.0 24"spans equally spaced, staggered center rows applied Smooth, torch -applied torch -applied 'TABLE ID: WOOD DECKS -NEW CONSTRUCTION or REROOF (Tear-0ff) SYSTEM TYPEf:'BONDED. ROOF_ COVER System Deck (Note 1) Roof Cover MDP No. Type Joint Treatment Base Ply Ply Cap (psf) W 21 Min. 15/32" plywood None EasyTorch SA Base, self-adhedng (Optional) EasyTorch SA Base, self -adhering EasyTorch APP Smooth or -75.0 at max. 24" spans or EasyTorch APP Smooth, torch -applied Granular, torch -applied W22 Min. 15/32"plywood Plywocdfolnts arewwred with 4-Inch wide strips of EasyTorch SA Baseself-adhering (Optional) EasyTorch SA Base, self -adhering EasyTorch APP Smooth or -120.0 at max. 24"spans EasyBase, rolled Into place to create continuous bond. , or EasyTorch APPSmooth,torch-applied Granular, torchapplied TABLE 2A--CONCRETE DECKS - NEW CONSTRUCTION or REROOF (Tear -Off) " t rs, - ` -- SYSTEM TYPE F.'NOWINSULATED,BONDED ROOF COVER - System No. Deck (Note 1) Primer Roof Cover MDP (pso Base Ply Ply Cap C-1. I Concrete I ASTM D41 I EasyTorch APP Smooth, torch -applied li (Optional) EasyTorch APP Smooth, torch -applied EasyTorch APP Smooth or Granular, torch -applied -670.0 Exterior Research and Design, U.C. d/b/a Trinity IERD Evaluation Report T37910.06.11-R4 for FL34672-R4 Cenifimte o7Au[hodzation #9503 Ern EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 10/02/2017 Prepared by; Robert Nieminen, PE-59166 LeakBarriere EasyTorch"' Modified Bitumen Roof Systems, (254) 913-7750 Appendix 1, Page 4 of 4 Florida Building Code Online 3/8/19, 11:00 AM Referenced Standard and Year (of Standard) Standard year ASTM D226 2009 ASTM D4601 2012 ASTM D6163 2008 ASTM D6222 2011 FM 4470 2012 FM 4474 2011 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 10/03/2017 10/07/2017 10/09/2017 12/12/2017 FL # Model, Number or Name Description 14672.1 LeakBarrier EasyTorch APP modified bitumen roof systems Modified Bitumen Roof Systems Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes F1_14672 R4 II 2017 10 FINAL Al ER TARCO MODBIT APP FL14672- R4.Ddj Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-670 Created by Independent Third Party: Yes Other: 1.) The design pressure in this application Evaluation Reports relates to one particular system. Refer to ER Appendix for all systems and Max Design FL14672 R4 AE 2017 10 FINAL ER TARCO MODBIT APP FL14672- R4.pdf Pressures. 2.) Refer to ER Section 5 for Limits of Use. Created by Independent Third Party: Yes Back Next Contact Us :: 2601 lu I Stone Road Tallahasseeliallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EE0 employer. C11vd9ht 2007-2013 State of Florida :: Pdyacy statement :: Accessibility Statement :: Refund Su Cement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -recants request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Honda Statutes, effective October 1, 2D12, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However emit addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click beLC. Product Approval Accepts: WT W rCri "Securit'lucs http://www.floridabuilding.org/prlpr_app_dti.aspx?param=W GEVXQwtDgsw8ZVNfe8A7egLDAylhYNUal9L6%2bUShfSFxOus6rNLEQ % 3d%3d Page 2 of 2