HomeMy WebLinkAboutKSM REPORTSKELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 P.O. BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 - www.ksmengineering.net MELBOURNE (321) 768-8488 FAX (561) 845-8876 E-Mail: KSM@KSMENGINEERING. NET ST. LUCIE (772) 229-9093 C.A.: 5693 FAX (772) 589-6469 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 DATE TESTED December 12, 2016 KSM JOB # : 163387-1 d/ES/aj PERMIT # 1609-0410 SCANNED CONTRACTOR BKV Homes BY St. Lucie County JOB LOCATION 2506 Tamarind Drive Ft. Pierce, Florida ITEM TESTED Compacted Foundation Fill TEST -LOCATION DEPTH "PEN DRY MAX.DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION 1. N.E. 0" - 12" 40 110.3 112.0 98.5 2. N.W. 42 108.4 96.8 3. Center .., 40 108.7 97.1 4. S.W. 44 107.7 96.2 5. S.E. 40 108.6 97.0 Soil Description: Brown Sand W 113.0 1 I I I I I E I I I I I I In Place Moisture: I I I I I I I 8.8 Percent H 112.0 Optimum Moisture: T I I I I I I I I I I 11.0 Percent P I I I I I Max. Dry Density: C 111.0 4 ..—..I—.. I .1_.._.r_.._.I._.. I._.._ 112.0 P.C.F. I I I I F I I I I I @ Test Locations The Density &Penetrometer 110.� 0 ' I I I I I Readings Indicate the D I I I I I I Degreq,.ofQb!!p ;ion Meets R 4� 109.0 8 .._.9.._.110.._111 12 113 14 P gt,ReadingS Taken to'dVatural Grade. Resk itt, Moisture % Dry Weight •: - of s `I; RECEIVED DEC 19.2016 f* County Building Department Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366 12/13/20IG 18:06 7725296469 KSM ENGINEERIM PAGE 01/01 nIJiva KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337.7755 P.O. BOX 78-1.377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) W-7445 wwaw.ksmengineering.not MELBOURNE (321) 768.8488 FAX (561) 345-8676 E-Mail: KSMOKSMENGINEERING.NET ST LUCIE (772) 229-9093 C.A.: 6693 FAX (772) 589-6469 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 DATE TESTED PERMIT* CONTRACTOR JOB LOCATION December 12, 2016 1609-0410 BKV Homes 2506 Tamarind Drive Ft. Pierce, Florida KSM JOB # : 163387-1 d/ES/aj SCANNED BY St. Lucie County ITEM TESTED : Compacted Foundation Fill TEST LOCATION DEPTH "PEN DRY MAX. DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION 1. N.E. 0" -12" 40 110.3 112.0 98.5 2. N.W. 42 108.4 96.8 3. Center 40 108.7 97.1 4. S.W. 44 107.7 95.2 5. S.E. 40 108.6 97.0 Soil Description: 113.0 T I I I I I Brown Sand W E I I I I I 1 In Place Moisture: I I I I I I I 8.8Percent H 112.0—L_.._L---- I I 1 I I Optimum Moisture: T I I I I I 11.0 Percent p I I I I I Max. Dry Density: 111.0 �• — •j—•• •j—••_.f_.._�._.. j._.. _ 112.0 P.C.F. l I I I I F I I I I I @ Test Locations The l I I I I I Density &Pam ometer 110.0 1-••_.,._.._.._.._.._.._..._.._.._.._ Rea §' dig,, I I I I I "%i R I I I t 1 De �4�f �i 'ilQeets Y I I I I I I � ! 109.0 iba—.._. i_.._.j_.._.j_.._.j._.._j._.._ r Uts ke anon. �',� � 8 9 10 11 72 13 14 r Pe a to flatural Grade. . ectfci tt ? Moisture- Yo of Dry Weight resift) �'„s����•- RECEIVED DEC 14,2016 INaIrt0O: St, Lucie County Building Department Email to: msalas8347@gmail.com.com Ronald G. Keller, RE.: 37293 / SI Lic, No.: 800 / Julie E. Keller, P.E.: 68366