HomeMy WebLinkAboutTRUSS PAPERWORKLIU -
STATE O� 1 tU \
o) 2
rL OR
Pop
VTE��fl
FDR/''I ANTE
NOTES:
1.)REFER TO HIB 91 (RECOMMENDATIONS
FOR HANDLING INSTALATION AND
TEMPORARY BRACING.) REFER TO
ENGINEERED DRAWINGS FOR PERMANENT
BRACING REQUIRED.
2.F�AA�B,,rLT��RUS��SE;.� (INCLUDING TRUSSES UNDER
VALLEYdFRAMING) MUST BE COMPLETELY
DECKED OR REFER OR DETAIL V105 FOR
ALTERNATE BRACING REQUIREMENTS.
3.)ALL VALLEYS ARE TO BE
CONVENTIONALLY FRAMED BY BUILDER.
4.)ALL TRUSSES ARE DESIGNED FOR 2' o,
MAXIMUM SPACING UNLESS OTHERWISE
NOTED.
S.)ALL WALLS SHOWN ON PLACEMENT PLAN
ARE CONSIDERED LOAD BEARING UNLESS
OTHERWISE NOTED.
6.)SY42 TRUSSES MUST BE INSTALLED WITH
THE TOP BEING UP.
7.)BEAM/HEADER/LINTEL (HDR) TO BE
FURNISHED BY BUILDER.
Jacksonville
PHONE 904 n24100 FAX 904-772-1973
Tampa
PHONE: 8IM21-9831 FAX 813A26-8956
Freeport
PHONE: 830-8354541 FAX BSU354532
BUILDER
Brookville Homes, Inc.
LEGALADDREBG:
2506 Tamarir
t Pierce, FL
Revision:
Rev. By.
P.: W - Drawn By.
7126/16 CJ 848709
MITEK PLATE APPROVAL #'s 2197.2 - 2197.4, WEYERHA
ER PRODUCT #'s 1630.2 - 1630.10
848709
Lq Builders
. FirstSource
1602 Industrial Park Dr.
Plant City, FL 33566
rodeo Information: Builder•. Brookville Homes, Inc.
Model: Sturgen Res.
Builder, Find... Job 4: 848709
Street: 2506 Tamarind Drive
City: Fort Pierce
.County: Saint Lurie.
Building Code: FBC2014/7PI2007
Computer Program Used:
Truss Design Information: Gravity Loads Wind
Roof. 37 psf Total Wind Standard: ASCE 7-10
Floor. Wand Speed: 170 mph
Mean Roof Ht: 15It Exposure: C
Note: Refer to individual truss design drawings for special loading conditions,
design criteria, truss geometry, lumber, and plate information.
Design Professional Information:
Design Professional Of Record: Licensefl:
Delegated Truss En tneer. Robert W. Wall Lieense 4 : 46021
This inns specification package consists ofthis index sheet and 65 tmss design drawings.
This signed and sealed index sheet indicates acceptance ofray professional engineering
responsibility solely for listed mass design drawings. The suitability and use of each imss
component for any particular building is the responsibility of the building designer perTPL
,,..PP,, E .'.
�'•leik�l�t5
gt C
b'O•. F P •: y.TC
s.'•. �OBW : •ab,F
G`.ef
lSS .AL
neeaaurrav�
08/2s/2016
Texts
4
Truss
Label
Denerag
4
Seat
Date
Truss
4
Trust
Label
Drawing
B
Seal
Date
Truss
B
Truss
Label
Drawing
4
Seal
Date
1
CJ01
848709001
7/26/2016
31
T19
848709031
7/26/2016
61
V09
848709061
726/2016
2
CJ02
848709002
7/26/2016
32
T20
848709032
7/262015
62
V10
848709062
7/26/2016
3
CJ03
848709003
726/2016
33
T21
848709033
7/262016
63
V11
848709063
726/2016
4
CJ04
848709004
7/262016
34
T22
848709034
7/26/2016
64
V12
848709064
726/2016
5
EJ01
848709005
7/262016
35
T23
848709035
7/262016
65
V13
848709065
7262016
6
EJ02
848709006
7/26/2016
36
T24
848709036
7/26/2016
7
EJ03
848709007
7/26/2016
37
T25
848709037
7/26/2016
8
EJ04
848709008
7/26/2016
38
T26
848709038
7/262016
9
EJ05
848709009
7/26/2016
39
T27
848709039
7/26/2016
10
EJ06
848709010
7/262016
1 40
T28
848709040
7262016
11
HJ01
848709011
726/2016
41
T29
848709041
7262016
12
HJ02
848709012
7262016
42
T30
848709042
726/2016
13
T01
848709013
7262016
43
T31
848709043
726/2016
14
T02
848709014
7262016
44
T32
848709044
726/2016
15
T03
848709015
7262016
45
T33
848709045
726/2016
16
T04
848709016
7262016
46
T34
848709046
726/2016
17
T05
848709017
7262016
47
T35
848709047
726/2016
18
T08
048709018
7262016
48
T36
848709048
7262016
19
T07
848709019
7262016
49
T37
848709049
7262016
20
T08
848709020
7262016
50
T38
848709050
7262016
21
T09
848709021
7262016
51
T39
848709051
726/2016
22
T10
848709022
7262016
52
T40
848709052
7262016
23
T11
848709023
7262016
53
V01
848709053
7262016
24
T12
848709024
7262016
54
V02
848709054
7262016
25
T13
848709025
7262016
55
V03
848709055
7262016
26
T14
848709026
7/262016
56
VO4
848709056
7262016
27
T15
848709027
7262016
57
V05
848709057
7262016
28
T16
848709028
7262016
58
VO6
848709058
7262016
29
T17
848709029
7262016
59
V07
848709059
1262016
30
T18
848709030
7262016
60
1 V08
1 848706660
7262016
EF
Page 1 of 1
7
0 toss
Was ype y
M8709 - Sturgell Res.
848709 CJ01
Jack -Open 20 1
M8709001
J b Ref a cs (optional)
6ellpela rusmource, runt Pry, FL 33566
Scale =1:7.6
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL in
(loci Udell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.25
Vert(LL) -0.00
7 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.04
Vert(TL) 0.00
7 >999 240
BCLL 0.0
Rep Stress lncr YES
WB 0.00
Horz(TL) 0.00
2 n/a n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix-M)
Weight: 6lb FT-20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP N0.2
TOP CHORD
Structural wood sheathing directly applied or 1-0-0 oc purlins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation uide.
REACTIONS. (lb/size) 2=154/0-8-0 (min. 0-1-8),4=-7/Mechanical,3=2/Mechanical
Max Horz2=58(LC 12)
Max Uplilt2=-93(LC 12), 4--7(LC 1), 3=6(LC 12)
Mu Grav2=154(LC 1), 4=17(LC 8).3=10(LC 8)
FORCES. (Ib) - Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
NOTES- (7)
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL-3.0psf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Extertor(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4, 3.
6) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this buss.
7j "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
.a` OEAI W'
! S
•,•• STATE OF •• Q
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016
o ruse ruse ype y M8709-Stume6 Res.
848]09 CJ02 Jack -Open 19 1 MB709002
Job Reference (opTonal)
Builders FInItUource, Plant Ciy, FL 33566 Run: 7.610 a Jan 29 2015 PnnC 7.610 a Jan 29 2015 Wlak Industries, Inc. Tue Jul 252191:162016 Pag9e 1
ID:oB3FwmhkmDOkA20AOiCOM?yu7CB-ayjrdNZUjSLVLbbO?YnHUv_HibUH(ANhm syu5C%
Scale -1:126
Plate Offsets (X,Y)--
t2:0-4-0,0-0-41
LOADING (psf)
SPACING- 2-0-0
CSL
DEFL
in
(loc)
Well
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.25
Vert(LL)
-0.00
7
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.07
Vert(TL)
-0.01
4-7
>999
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.00
Horz(TL)
0.00
2
n/a
n1a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Weight: 12 lb FT-20%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
REACTIONS. (lb/size) 3=57/Mechanical, 2=21010-8-0 (min. 0-1 -8), 4=26/Mechanical
Max Hom2=113(LC 12)
Max Uplift3=-62(LC 12), 2--108(LC 12), 4=-l(LC 12)
Max Grav3=57(LC 1), 2=21 O(LC 1), 4=45(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
BOTCHORD 2-4=168/340
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc puriins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES- (7)
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL-3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Extenor(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 pelf bottom chord live load nonconcurrent with any other live loads.
3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5)'Provide mechanical Connection (by others) of truss to bearing plate capable of withstanding 100 to uplift at joint(s) 3, 4 except 6tAlo)
2-108.
6) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
7) "This manufactured product is designed as an Individual building component The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
IN,
STATE OF
0 XORID
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559 08/25/2016
Truss Truss Type 848709-Sturgell Res
M8709 CJ03 Jack -Open 8 1 M8709003
Job Reference (optional)
Builders FrsnSourm, Plant Cry, R. M566 Run:7.610s Jan292U15P4n07.610sJan292015Weklndustres,lnc Tue Ju12621U1:1]2016 Pa9ga1
ID:oB3FwmhkmDOkA20AOiCOM?yu7CB-29HEgja6UmTMyUIaZFIWOSWPxHCI01OXwVf2?I WSCVu
I
fy-0 I 5-0-0 I
3x4 =
LOADING (psf)
SPACING-
2-0-0
CSI.
TCLL
20.0
Plate Grip DOL
1.25
TC 0.42
TCDL
7.0
Lumber DOL
1.25
BC 0.20
BCLL
0.0 '
Rep Stress Incr
YES
WE 0.00
BCDL
10.0
Code FBC2014/TPI2007
(Matrix-M)
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No-2
REACTIONS. (lb/size) 3-100/Mechanical, 2=297/0-8-0 (min. 0-1-8), 4=44/Mechanical
Max Horz2=169(LC 12)
Max Uplih3=-110(LC 12). 2= 146(LC 12)
Max Grav3=100(LC 1), 2=297(LC 1), 4=75(LC 3)
FORCES. (16) - Max. CompJMax. Ten. -All forces 250 (to) or less except when shown.
TOP CHORD 2-3--645/535
BOT CHORD 2-4=1033/947
Scale a 1:17.7
DEFL in floc) Udell L/d PLATES GRIP
Vert(LL) 0.03 4-7 >999 360 MT20 244/190
Vert(TL) -0.04 4-7 >999 240
Horz(TL) -0.00 3 n/a n/a
Weight: 181b FT=20%
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES- (7)
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2ps1; BCDL=3.Opst h=15ft, Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and GC Extedor(2) zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcunent with any other live loads.
3)' This truss has been designed for a live load of 20.OpSf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 3=110,
2=146.
6) "Semi -rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
7)'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.'
LOAD CASE(S) Standard
W.
q, STATE OF 2
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559 08/25/2O16
o n156
I russ lype Uny my
B48709-SNrgeil Res.
848]09 CJ04
Jack4Jpen 1 1
M8709004
Job Reference (optional)
Builders RnstScurce, Plant City, F133566
2x4 =
Run: 7.610 s Jan 29 2015 Pdni: 7.610 s Jan 29 2015 m ek Industries, Inc. Tue Jul 2621 U1:112016 Pa5e 1
ID:oB3FwmhkmDOkA20ADICOM?yu7CB-29HEgja6UmTMylAaZFI W 05 W RUHELOIOXW Vf2?lyuSCW
3-0-0
Scale=1:11.9
LOADING (psQ
SPACING-
2-0-0
CSI.
DEFL in
floc) Vdefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.26
Vert(LL) -0.00
1-3 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.09
Vert(TL) -0.01
1-3 >999 240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(TL) -0.00
2 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix)
Weight: lO lb FT-20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 3-0-0 oc purlins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
M7ek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (lb/size) 1=106/Mechanical, 2-78/Mechanical, 3=29/Mechanical
Max Ho¢ 1=84(LC 12)
Max Upliftl= 37(LC 12). 2=90(LC 12)
Max Grav1=106(LC 1), 2=78(LC 1), 3=58(LC 3)
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES- (7)
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL-4.2psf; BCDL=3.Opsf; h-15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL-1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
3)' This truss has been designed for a live load of 20.Opsf on the bottom chard in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ile uplift at joint(s) 1, 2.
6) "Semi -rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
7)'This manufactured product is designed as an individual building component The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.'
LOAD CASE(S) Standard
STATEOF
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016
oTruss
mss I ype Uly Ply
848709 - Suagell Res.
84B]09 1E,101
Jack-Padisl 34 1
M8709005
Job Reference (optional)
Builders Rm Scu¢e, Plant City, FL 33566
3
.T-
Run: 7.610 a Jan 292015 Print: 7.610 a Jan 29 2015 Was Industries, Inc. Tue Jul 26 21-01:182016 Page 1
IDmB3FwmhkmDOkA20AOiCOM7yu7CS-W Lrc23bkF3cDavlm7zgl7J3SDhW HIIgg89PcXkyu5CV
Scale =1225
Plate Offsets (X,Y)--
t2:0-6-0,0-0-101
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL
in
(loc)
Udefl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.90
Vert(LL)
0.08
4-7
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.37
Vert(TL)
-0.16
4-7
>533
240
BCLL 0.0 '
Rep Stress Incr YES
W B 0.00
Hom(TL)
-0.01
3
n/a
n/a
BCDL 10.0
Code FBC2014frP12007
(Matrix-M)
Weight: 241In FT=20%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
REACTIONS. (lb/size) 3=141/Mechanical, 2=388/0-8-0 (min. 0-1-8), 4-60/Mechanical
Max Hom2=224(LC 12)
Max Uplift3=-156(LC 12). 2--185(LC 12)
Max Grav3=141(LC 1), 2=388(LC 1), 4-105(LC 3)
FORCES. (lb) - Max. CompJMax. Ten. -All tomes 250 (lb) or less except when shown.
TOP CHORD 22=-1306/1301
SOT CHORD 2-4= 2259/1927
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc pudins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES- (7)
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2pst BCDL=3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Extedor(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 3=156,
2=186.
6)'Semi-6gid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
7) -This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code'
LOAD CASE(S) Standard
STATE OF
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016
JOID Imes
I was I yp0 Lay
U8709 - Sturgen Res.
U8709 E102
Fly
Jack-Parllal 5 1
848709006
Job Reference (ootiona0
aNlders RrstSource, Plant City, PL 33566
KJA-m
Run: 7.610 s Jan 29 2m5 P4nL 7.610 s Jana 2015 64Tex ineustrles, Inc. Tue Jul 2621 U1:16 2016 Page 1
ID:oB3FwmhkmDOkA20AOiCOM7yu7CB-WLrc23bkF3cDavim7zqIZJ3SJhVLIgg89PcXkyu5CV
7-0-0
7-0-0
Scale =121 A
Plate Offsets (X,Y)-
11:0-3-0 0-0-121
LOADING (psQ
SPACING.
2-0-0
CSI.
DEFL
in
(lac)
Well
Ltd
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.90
Vert(LL)
0.08
3-6
>993
360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.39
Vert(TL)
-0.16
3-6
>521
240
BCLL 0.0 '
Rep Stress [nor
YES
WS 0.00
Horz(TL)
-0.01
2
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix-M)
Weight: 22 lb FT=20%
LUMBER -
TOP CHORD 2x4 SP No.2
SOT CHORD 2x4 SP No.2
REACTIONS. (lb/size) 1=310/Mechanical, 2=142/Mechanical, 3=61/Mechanical
Max Harz 1=193(LC 12)
Max Upliftl= 134(LC 12), 2=-157(LC 12)
Max Gmvl=310(LC 1), 2=142(LC 1), 3=106(LC 3)
FORCES. (Ib) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2— 1286/1519
BOTCHORD 1�3-2562/1938
BRACING -
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES- (7)
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.0psf; h=1511; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Extedor(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at -lb) 1=134,
2=157.
6) "Semi -rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
7)'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.'
LOAD CASE(S) Standard
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559
TIT W. �yq •.
S4�'I��ENs<c :!Ir
STATE OFRID
0A into P.
:�-
c\ O
08/25/2016
Joo I Was
m55 IYPD Fly
848709. Sturgell Res.
M8709 EI03
Jack-Panal 1 1
84B709007
Job Reference (optional)
bui0ere'Neekeu2re, Plant City, FL 33566 Ran: 7.6105 Jan a 2015 Pnnn 7.6105 Jan 292015 M I eK IWYSInes, M NB J01262"1:192016 Pagel
ID:oS3FwmhkmDOkA20AOiCOM?yu7CB-?XP FObMONk4C3KyggL_5Wci15p2UB3pNp894ByuCU
-1 1 6-0-0
1-0-0 6-0-0
46 =
Scale =121.6
6-0.0
-0-0
LOADING (psf)
SPACING- 2-0-0
CSI.
OEFL in
(too) Well Ud
PLATES GRIP
TOLL 20.0
Plate Grip DOL 1.25
TC 0.60
Vert(LL) 0.14
6-9 >606 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.53
Vert(TL) -0.16
6-9 >523 240
BCLL 0.0 '
Rep Stress Incr YES
WS 0.12
HOrz(TL) -0.04
4 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Weight: 28 lb FT - 20
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 4-11-6 oc purlins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
• WEBS 2x4 SP No.3
Mi rek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) 4=32/Mechanical, 2=387/0-8-0 (min. 0-1-8),
5=169/Mechanical
Max Horz2=199(LC 12)
• Max Uplift4= 13(LC 8), 2=-194(LC 12), 5=-142(LC
12)
Max Grav4=51(LC 3), 2=387(LC 1), 5=169(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3= 1300/1289
BOT CHORD 2-6= 2104/1854
WEBS 3-6=-216/403
NOTES (9)
1) Unbalanced root live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL-4.2psh BCDL=3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MW FRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL-1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 pat bottom chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of 20.Opst on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except Qt=lb) 2-194,
5=142.
8)'Semi-rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.'
LOAD CASE(S) Standard
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559
W. y
STATE OF
�9O.o �• ;LORID�;� ,
08/25/2016
848709
4x6 =
4-0-0 7-0-0
4-0-0 I 3-0-0
Scale =1:16.6
Plate Offsets(X,Y)—
f2:0-1-0,Edgel
LOADING (psf)
SPACING. 2-0-0
CST.
DEFL
in
(loc)
Udell
L/d
PLATES GRIP
TCLL 20.0
Plate Grip OOL 1.25
TC 0.47
Vert(LL)
0.18
6
>467
360
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.60
Ved(TL)
-0.18
6
>452
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.08
Hoa(TL)
0.09
4
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matdx-M)
Weight: 27 lb FT=20%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 4=103/Mechanical, 2=390/0-8-0 (min. 0-1-8), 5=96/Mechanical
Max Horz2=143(LC 12)
Max Uplift4= 78(LC 9), 2=-197(LC 12), 5=-31(TO 9)
Max Grav4=103(LC 1), 2=390(LC 1), 5=100(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3--1326/1337
BOT CHORD 2-6= 2016/1833
WEBS 3-6=-136/265
BRACING -
TOP CHORD Structural wood sheathing directly applied or 4-10-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES- (9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCOL=4.2psf; BCDL=3.Opsf; h-15111; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Fxtedor(2) zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5 except Qt=lb)
2=197.
8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used 1n the analysis and design of this truss.
9)'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.'
LOAD CASE(S) Standard
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559
.q, STATE OF 2
08/25/2016
Job Truss
Was I ype y
846]09-Stur9ell Bes.
M709 EJ05
Half Hip SuppwLLW 1 1
848]09009
Job Reference o tlonal
Builders PlrslSource, Plant City, FL33566 Herezelos Jan2ezol5Pnnc Lblu S Janz9zmbwiexmausmes, aa: ue Jmzbzl:m:euzol6 Pagel
ID:oB3FwmhkmDOkA20AOiCOM?yu7C&T1zM1kc_nhsxpDv9EOsDek8uUGADfimTujcdyuSCT
Aj0 2-0-12 34A2 4-8-12 6-0-12 7-0-0
r i-0 2-0-12 4-1-4-0 f— 1-4-0 1-4-0 0-11-4
Scale=1:15.6
46 =
LOADING (pso
SPACING-
2-0-0
CS].
DEFL in
(loc) VdeO L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.25
Vert(LL) -0.00
1 n/r 120
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.09
Ven(TL) -0.00
1 n/r 120
BCLL 0.0 '
Rep Stress Incr
YES
W B 0.03
Horz(TL) -0.00
7 n/a n/a
BCDL 10.0
Code FBC2014frP12007
(Matrix)
Weight: 28 lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.2
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. All bearings 7-0-0.
(Ib) - Max Horz 2=132(LC 12)
Max Uplift All uplift 100 lb or less at joints) 7, 12, 10, 9 except 2=-170(LC 12), 111 15(LC 8)
Max Grav All reactions 250 lb or less at joint(s) 7, 2, 8, 12, 11, 10, 9
FORCES. (Ib) - Max. Comp./Max. Ten. -Aft forces 250 (Ib) or less except when shown.
NOTES- (12)
1) Unbalanced root live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL-3.Opsf•, h=1 Sit; Cat. II; Exp C; Encl., GCpi=U.18;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL-1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSVTPI 1.
4) Provide adequate drainage to prevent water pending.
5) All plates are 2x4 MT20 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 1-4-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) 7, 12, 10, 9 except
Qt=lb) 2=170, 11-115.
11) "Semi -rigid pitchbreaks with fixed heels- Member end fixity model was used in the analysis and design of this truss.
12) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
W.
,o ; STATE OF
cLOSIO?.c\�z4 C
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, Fl 33559 08/25/2016
Job russ I was I ype Uty Fly 848709-SNrgell Res.
W709 FJO6 Jack-Panial Is 1 848709010
Job Reference (optional)
Builders RroSource, Plant City, FL 33566 Run: 7.610 s Jan 292015 Pont: 1.61U s Jan 29 20[5 NTek Industries, Inc. Tue Jul 2621 V 20 2016 Page 1
IDmB3FwmhkmDOkA20AOiCOM9p7CB-TIzMTkc_nhsxpDv9EOsDekBwBUESDfAz TujoZ CT
Scale=1:17.4
3x4 =
s-0-o
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL in
(lac) I/defl Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.42
Vert(LL) 0.03
4-7 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.20
Vert(TL) -0.04
4-7 >999 240
BCLL 0.0 '
Rep Stress ]nor YES
W B 0.00
Horz(fl-) -0.00
3 n1a n/a
BCDL 10.0
Code FBC2014ITP12007
(Matrix-M)
Weight: 181b FT-20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 5-0-0 oc pur ins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (lb/size) 3=100/Mechanical, 2=297/0-8-0 (min. 0-1-8).
4=44/Mechanical
Max Horz2=168(LC 12)
Max Uplif13=110(LC 12), 2= 146(LC 12)
Max Gmv3=100(LC 1), 2=297(LC 1), 4=75(LC 3)
FORCES. fib) - Max. CompJMax. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3= 645/535
BOT CHORD 2-4--1032/947
NOTES (7)
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL-4.2psf; BCDL=3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MW FRS (envelope) and C-C Exterior(2) zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL-1.60 plate grip
DOL-1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any ogler live loads.
3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical Connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) except Ot=lb) 3=110.
2=146.
6) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
7) This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
Ar :
STATE OF
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559 08/25/2016
o nem
Ws6 I ype Uty Fly
848709-Sturgell Res.
848709 HJo1
I Diagonal Hip 56der 4 1
848709011
Job Reference (optional)
Builders FvstSour , Pant City, FL 33566
i
3x4 =
Sallee =1 M3
d -
Plate Offsets (X y)--
I2:0-0-13,Edgel
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL
in
(too)
Vdefl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.67
Vert(LL)
0.26
6-7
>444
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.84
Vert(TL)
-0.39
6-7
>301
240
BOLL 0.0 `
Rep Stress Incr NO
WB 0.14
Horz(TL)
0.01
5
n/a
n/a
BCDL 10.0
Code FBC2014/rP12007
(Matdx-M)
Weight: 401b FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD
BOT CHORD 2x4 SP No.1 BOT CHORD
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 4=161/Mechanical, 2-301/0-10-15 (min. 0-1-8), 5=186/Mechanical
Max Horz2=248(LC 22)
Max Uplift4=-166(LC 4). 2=-256(LC 4). 5=-102(LC 8)
Max Grav4=161(LC 1), 2=391(LC 19), 5=196(LC 3)
FORCES. (Ib) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-11=-963/330, 2-12--498/334, 12-13= 497/343, 3-13=-448/301
BOT CHORD 2-15= 434/1039, 2-16=-385/434, 16-17--385/434, 7-17--385/434, 6-7=-385(434
WEBS 3-7=-103/270,3-6=-518/460
Structural wood sheathing directly applied or 6-0-0 oc purlins
Rigid ceiling directly applied or 8-9-13 oc bracing.
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES- (9)
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL-4.2psf; BCDL=3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MW FRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcunent with any other live loads.
3) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 Wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 It, uplift at joint(s) except (jWb) 4=166,
2=256, 5=102.
6)'Semi-rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 88lb down and 74 Ib up at 1-4-15,
88 Ib down and 74 Ib up at 1-4-15. 93 It, down and 65 Ib up at 4-2-15, 93 Ib down and 65 Ib up at 4-2-15, and 111 Ib down and l l2 Ib
up at 7-0-14, and 111 Ib down and l l2lb up at 7-0-14 on top chord, and 16 Ib down and 471b up at 1-4-15. 16 It, down and 471b up at
1-4-15, 191b down and 29 Ib up at 4-2-15, 19 Ib down and 29 Ib up al 4-2-15, and 33Ib down and 16 lb up at 7-0-14, and 33Ib down
and 16 Ib up at 7-0-14 on bottom chord. The design/selection of such Connection device(s) is the responsibility of others. fib¢+�++++4y
8) In the LOAD CASE(S) section, loads applied to the face of the buss are noted as front (F) or back (B). r�OOT W. (y+4•
9)'This manufactured product is designed as an individual building component. The suitability and use of this component for any parti 9 ••.
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.' £$ , '�-1GENSf'•�C S
LOAD CASE(S) Standard .rT '
1) Dead+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pit) �j�✓LW7
Vert: 1-2=-54, 2-11_ 14, 4-11=-54, 5-8=-20 ,d ; STATE OF
Concentrated Loads(Ib) •y9'•. p
Vert: 6= 31(F=-15, B=-15)12=148(F=74, 8=74)13=40(F=20, B=20) 14=46(F=-23, 8=23) 16=50(F=25, 8=25) 17=5(F=3, B�3�'ct-�• �QR��A ;N%V�'��
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559 08/25/2016
Job Truss
Was Fype City Pry
648709-SWrgell R.S.
848709 HJ02
Dlagdnal Hip Girder 6 1
M8709012
Job Reference (optional)
Builders rensoume, rum ury, M aa56B
i
3x4 =
Hun: 7.610 s Jan a 2015 Pdnl:7.6105 Jan 29 2015 KTex InduMee, Inc. Tue Ju126 21 U1222016 Page t
ID:oB3FvrtnhkmDOkA20AOiCOM?yu7CB-P647t0eFJl6e3 W2XMpuhj9DFwlvdhZIG3nNpg WyuSdCR
Scale=1:17.4
LOADING lost)
SPACING- 2-0-0
CSI.
DEFL in
(loc) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TO 0.47
Vert(LL) -0.04
4-7 >999 360
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.28
Vert(TL) -0.10
4-7 >796 240
BCLL 0.0
Rep Stress Incr NO
W B 0.00
Horz(TL) 0.00
2 n/a n/a
BCDL 10.0
Code FBC2014frPI2007
(Matrix-M)
Weight: 25 He FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP N0.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.2
SOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
M7ek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation uide.
REACTIONS. (lb/size) 3=114/Mechanical, 2=199/0-10-15 (min. 0-1-8), 4=49/Mechanical
Max Horz2=192(LC 4)
Max Uplifl3= 128(LC 8), 2=-201(LC 4)
Max Grav3=134(LC 19). 2=298(LC 19). 4=89(LC 3)
FORCES. (lb) - Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-8=-905/317
GOT CHORD 2-11--438/944
NOTES- (9)
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.0psf; h-151t; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL-1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 He uplift at joints) except (jt=lb) 3=128.
2=201.
6) "Semi -rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 88lb down and 74 Ib up at 1-4-15,
88 lb down and 74 lb up at 1-4-15, and 93 Ib down and 65 lb up at 4-2-15, and 93 lb doom and 65 lb up at 4-2-15 on top chord, and 16
Ito down and 47lb up at 1-4-15, 16 He down and 47 Ile up at 1-4-15, and 19 Ib down and 29 Ile up at 4-2-15, and 19 lb down and 29 lb up
at 4-2-15 on bottom chard. The design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, (cads applied to the face of the truss are noted as front (F) or back (B).
9)'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.' -
LOAD CASE(S) Standard �•`-pp-••""'• '4 1,
1) Dead+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Q` ,. y�GENSF, !!4`
Uniform Loads (pill
Vert: 1-2--54,2-8=-14, 3-8--5414-5= 20 '
Concentrated Loads (lb)
Vert: 9=148(F=74, B=74) 10=40(F=20, B=20) 12=50(F=25, B=25) 13=5(F=3, B=3) :.q% STATE 17FG(.1/7
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559 08/25/2016
Job ms5
inuss lype ly
B4a709-Shvgel1Res.
MB709 ml
"to Girder i 1
M8709013
_
-
Job Reference foptionall
Builders RrstSource, Plant City, FL 33566
1,
4x6 =
3
Sx4 =
4
12
416 =
3x6 = 3x4 = 4x6 = 3x4 = 3x6 =
Seale =1385
m
to
LOADING (psf)
TOLL 20.0
TCDL 7.0
BCLL 0.0 '
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr NO
Code FBC2014/TP12007
CSI.
TO 0.77
BC 0.73
WB 0.25
(Matrix)
DEFL in
Vert(LL) 0.13
Vert(TL) -0.35
Horz(TL) 0.08
(too) Udell L/d
6-8 >999 360
8-10 >718 240
6 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 94 lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.1
TOP CHORD
Structural wood sheathing directly applied or 2-11-15 oc purlins.
BOT CHORD 2x4 SP No.t
BOT CHORD
Rigid ceiling directly applied or 5-1-9 oc bracing.
- WEBS 2x4 SP No.3
MiTek recommends that Stabilizers end required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (lb/size) 2=1421/0-8-0 (min. 0-1-11), 6=142110-8-0 (min.0-1-11)
Max 1-1=2=-94(LC 25)
Max Uplift2— 914(LC 8), 6=-945(LC 9)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=2437/1545, 3-11=-2099/1456, 4-11— 2099/1455, 4-12= 2099/1513,
5-12=2099/1513,
5-6= 2437/1612
BOT CHORD 2-10=-1305/2074, 10-13=-1483/2279, 9-13=-1483/2279, 9-14=-1493/2279,
14-15=-1483/2279,
8-15=.1483/2279, 6-8=-1278/2074
WEBS 3-10=-291/661, 4-10— 322/368, 4-8= 347/346, 5-8=-275/662
NOTES- (10)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2pst BCDL-3.Opsf; h=151t; Cat. II; Exp C; Encl., GCpi=0.18;
MW FRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will Tit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except aWth) 2=914,
6=945.
7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) P28 lb down and 330 Ib up at 7-0-0,
108 Ito down and 158 Ib up at 9-0-12, 108 lb down and 158 lb up at 10-8-0, and 108 It, down and 158 Ib up at 12-3-4, and 171 lb down
and 3601h up at 14-4-0 on top chord, and 205 lb down and 1341b up at 7-0-0, 65 lb down and 3 Ito up at 9-0-12, 65 lb down and 3 Ito up
at 10-8.0, and 65 lb down and 3 lb up at 12-3-4, and 205lb down and 134lb up at 14-3-4 on bottom chord. The design/selection of anu.uap�•
such connection device(s) is the responsibility of others. tiQ1 W, ••4•
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). Q O�S'q •L
10) "This manufactured product is designed as an Individual building component. The suitability and use of this component for any tom° Q' \CENSF ••C! S,
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard * : �i1t t fl -• 1 a
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pit) {,o ; STATE OF Q
Vert: 1-3— 54, 3-5= 54, 5-7=-54, 2-6=-20 •4gOq •• �ORIDP�
•'•asyo�va�
Continued on page 2 wahmalaaa
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016
O N66 NSe yPe O—PIy 9a9]09-SWrgell Res.
646]09 TOt Hip Giber 1 1 848709013
Job Reference (oo[iona)
Buldem RmtSourm, Plant City, FL 33566 Run:7.610 s Jan 292015 Print: 7.610 s Jan 29 2015 MTek Industries, Ina Tue Jul 262"1'232016 Pag9e 2
ID:oB3Fv hkinOOkA20AOiCOM?yu7CB-tleV5mft4cEVggdkWWPwGMmLOiBI0yzPIR6NDyyu5CO
LOAD CASE(S) Standard
Concentrated Loads (Ib)
Vert: 3=-171(S) 5=171(B) 10= 202(B) 4= 87(B) 8=-202(B) 11=-87(B) 12=-87(B) 13= 40(B) 14=-40(B) 15= 40(B)
v�.�0E41T W. jy�o
aJQO.��GENyF ;(`
14
STATE OF �� C
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, Fl 33559 08/25/2016
Job Fruss
ruse type y
648709-Sturgell Res.
U8709 T02
Hip 1 1
848709014
Job Reference (optional)
Builders FasnoarN. Plant City, FL 33566
5x6 =
3x4 =V
5x6 =
ax4 =
Scale =1385
11
Plate Offsets (X.Y)--
[2:0-2-10,0-1-8]. [4:0-3-0,0-2-71,
[5:0-3-0,0-2-71,
[7:0-2-10,0-1-81
LOADING (pat)
SPACING- 2-0-0
CS].
DEFL
in
floc)
VdeO
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.63
Ved(LL)
-0.14
7-9
>999
360
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.68
Vert(TL)
-0.38
7-9
>644
240
BCLL 0.0 '
Rep Stress Incr YES
W B 0.13
Hoa(TL)
0.04
7
We
n1a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
Weight: 98 lb FT=20%
LUMBER -
TOP CHORD 2x4 SP No.2 *Except*
T2: 2x6 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=858/0-8-0 (min. 0-1 -8), 7=858/0-8-0 (min. 0-1-8)
Max Horz 2=-115(LC 10)
Max Uplift2=409(LC 12), 7=409(LC 13)
BRACING -
TOP CHORD Structural wood sheathing directly applied or 4-1-6 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-1-15 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 fib) or less except when shown.
TOP CHORD 2-3=-1537/1191, 3-4=-1341/1085, 4-5= 1156/994, 5-6=-1341/1085, 6-7= 1537/1191
BOT CHORD 2-11=-832/1284, 10-11=-545/1061, 9-10=-545/1061, 7-9=-853/1294
WEBS 3-11--325/44414-11=-306/432, 5-9=-306/432, 6-9=-324/443
NOTES- (8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL =10.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) except (jt=1b) 2=409,
7-409.
7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard r""'......
Lyra,
� * • STATE OF
r�a4�9 ;;OR70p•G\�trx��'
rh Sy�NAI ENa•°
rrtltrurrspd
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016
job Fruss
I was I ype y
B48709-Saurgell Res.
868709 T03
Common Giber 1 3
Job Reference o ti0nal
Buldels Rst5ource, Plant City, FLM566 Run: 7.610 s Jan 292015 Print: 7.610 s Jan 29 2015 N4Tek Industries, Inc. Tue Ju126 21 x112d 2016 Page 1
ID:oB3FwmhkmDOkA20AOiCOM?yu7CB-LVCtl6fVwMMIgCwTEw9oaJaA6YC9FVYX5sW u5CP
6-L 10-B-0 14-11-5 21-"
6-4-11 I 4.3-5 --- _ _64-11
Scale =1:35.3
4x6 11
Ia
axa 11 1x1u= am 11
Plate Offsets (X Y)--
f1:0-2-10 0-1-81 (5:0-2-10,0-1-81 P:0-5-0,0-4-81
LOADING (lost)
SPACING- 2-0-0
CSI.
DEFL
in
(loc)
I/de8
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.55
Vert(LL)
0.14
6-7
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.40
Vert(TL)
-0.24
6-7
>999
240
BCLL 0.0 `
Rep Stress Incr NO
WB 0.87
Horz(TL)
0.05
5
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
Weight: 348 Ib FT=20%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x6 SP M 26
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 1=4735/0-8-0 (min. 0-1-14),5=5760/0-8.0 (min. 0-2-4)
Max Horz 1=-118(LC 4)
Max Uplifll= 2440(LC 8), 5=-3023(LC 9)
BRACING,
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
FORCES. (Ib) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-8993/4635, 2-3=-7990/4233, 3-4=-7991/4234, 45=-10692/5551
BOT CHORD 1-9— 4123l7913, 9-10=4123/7913, 10-11=-4123/7913, 8-11=-4123/7913, 8-12= 4123/7913,
12-13--4123/7913,7-13=412317913,7-14=-4830/9441, 14-15=-4830/9441, 6-15= 4830/9441,
6-16=-4a30/9441,16-17=-4830/9441,17-18— 4830/9441, 5-18=-4830/9441
WEBS 3-7=-3636/6883,4-7=-2922/1628,4-6=-13682781,2-7=-1024/614, 2-8--355/881
NOTES- (10)
1) 3-ply truss to be connected together with 1 Od (0.131 "xW) nails as follows:
Top chords connected as follows: 2x4 -1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-8-0 oc.
Webs connected as follows: 2x4 - 2 rows staggered at 0-6-0 oc, Except member 7-4 2x4 -1 row at 0-9-0 oc, member 4-6 2x4 -1 row at
0-9-0 oc, member 7-2 2x4 - i row at 0-9-0 oc, member 2-8 2x4 - 1 row at 0-9-0 Co.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.0psf; h=151t; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
5) This truss has been designed for a 1 OX psf bottom chord live load nonconcurtent with any other live loads.
6) ° This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=Ib) 1=2440, hill npi��
5=3023. d,00 iY
8) °Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. •J ��.....; �i�
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 290 It, down and 154 lb up at 1,3�-Q� •I,\O£N,q'F
290 lb down and 154lb up at 34-0, 290 Ib down and 154lb up at 54-0, 290 lb down and 154lb up at 7-4-0, 290 lb down and 15 b up
at 9-4-0, 3639 lb down and 2033 Ib up at 10-5-9, 949 lb down and 501 lb up at 12-3-4, 949 lb down and 493 lb up at 14-3-4, 9043b '.
down and 444 lb up at 16-3-4, and 986 It, down and 597lb up at 18-3-4, and 86 lb down and 57 lb up at 20-2-15 on bottom chorlt The 1
design/selection of such connection device(s) is the responsibility of others. 0. * %
10) "This manufactured product is designed as an individual building component. The suitability and use of this component for any I A STATE OF
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.' •� 9 .• t+ r�4;
LOAD CASE(S) Standard
Continued on page 2
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559
08/25/2016
Job Truss
Imes iype Uty Ply
646709-StuTgell Res.
646709 T03
Comman Girder 1
5ence
3
Job Ref090
(optional)
buuaem resuource, rum uty, M tl bbe
nun:r.em s den 29201 b Penn r.bi u s dan 292o] b m i eh lnausmes, Inc I u9 dui 2b arm242016 Paee2
D:oB3FwmhkmDOkA20AOiCOM?yu7CB-LVCtlsfVNMMIgGwTEw9oaJaA6VC9FVY%5swl0yu5CP
LOAD CASE(S) Standard
1) Dead +Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pit)
Vert: 1-3=-54, 3-5=-54, 1-5=-20
Concentrated Loads (lb)
Vert: 7--3639(F) 9= 290(F) 10=-290(F) 11 =-290(F) 12=-290(F) 13=-290(F) 14--949(F7 15— 949(F)16=904(F) 17=-986(F) 18=-86(F)
W,
STATE OF ,
'y9p ;FLOp'pP: �4i��d
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016
Hip ei 4.'
4x6 = —
3x4= 46=
4x1U MI<UHJ= 3x4= 5x6= 3x4=
Scale -1 nee
4x10 M I20HS=
Plate Offsets (X,Y)--
f2:0-5.0,0-1-71, f6:0-5-0,0-1.71
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
Vdefi
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.53
Vert(L-)
-0.11
7-9
>999
360
MT20
2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.68
Vert(TL)
-0.31
7-9
>750
240
MT20HS
187/143
BCLL 0.0 '
Rep Stress Incr NO
W B 0.33
Horz(TL)
0.05
6
n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix)
Weight: 102 lb
FT-20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-11-6 oc purlins.
BOT CHORD 2x6 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-3-10 oc bracing.
WEBS 2x4 SP No.3 MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) 6=1006/Mechanical, 2=1115/0-8-0 (min.0-1-8)
Max Horz2=83(LC 12)
Max Uplift6=577(LC 9), 2= 670(LC 8)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3= 1934/1071, 3-10=-1684/1 an, 10-11=-16a4/1009, 4-11= 1684/1009, 4-12=176311025,
12-13=-1763/1025, 5-13= 1763/1026, 5-6=-2001/1089
BOT CHORD 2-9=-922/1654, 9-14=-1380/2145, 14-15_ 1380/2145, 8-15= 1380/2145.8-16=138012145,
16-17=-1380/2145,7-17--1380/2145,6-7--938/1734
WEBS 3-9= 162/574, 4-9=-570/575, 4-7=-469/487, 5-7=-137/556
NOTES- (12)
1) Unbalanced root live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. 11; Exp C; Encl., GCpi=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except TAb) 6=577,
2=670.
9)'Semi-rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1951b down and 242lb up at 5-0-0 0%munts",
91 lb down and 112 lb up at 7-0-12, 91 lb down and 112 lb up at 9-0-12, 91 It, down and 112 lb up at 10-11-4, and 91 lb down ands� EPT W. h'01%
112 lb up at 12-11-4, and 175 lb down and 246 lb up at 15-0-0 on top chard, and 83 lb down and 22 lb up at 5-0-0, 35 lb down antyS�p`b.\GEI.. q(�4
lb up at 7-0-12, 35 It, down and 8lb up at 9-0-12, 35 lb down and 8lb up at 10-11-4, and 35 lb down and 8lb up at 12-11-4, andd'1�133
down and 22 lb up at 14-11-4 on bottom chord. The designtselection of such connection device(s) is the responsibility of others,
11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). •'
12) -This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.' : STATE OF Q
LOAD CASE(S) Standard �'O,n; 2pp101;��`
%
Continued on page 2
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559
08/25/2016
doo Iwo
I russ Type y
M8709 - Sturgeil Res.
848709 Tot
Hip Girder 1 1
B48709016
Job Reference (optional)
Builders Fv wrce, Plant City, FL33566
Run:7.610 s Jan 29 2015 Print: 7.510 s Jan 29 2015 MTek Industries, Inc. Tue Ju126 21:01:252016 Page 2
ID:o63FwmhkmDOkA20AOiCOM?yu7CS-phmFWSg7cDUDw_n61 xSOLnrIDVg7ugCillbUHryu5CO
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plo
Vert:1-3=54, 3-5=54, 5-6=-54, 2-6= 20
Concentrated Loads (Ib)
Vert: 3=-103(F) 5=103(F) 9=-47(F) 7=-47(F) 10=-46(F) 11=46(F) 12=-46(F)13=-46(F) 14= 24(F) 15— 24(F) 16_ 24(F) 17= 24(F)
lY,
STATE OF
Robert W. Wall, PF 46021
24710 State Road 54 Lutz, F133559 08/25/2016
Job russ
was I ype UEY FlY
M8709-Stage6 R.S.
U8709 T05
Hip I 1
M8709017
Job Reference (optional)
Oveaere halS'ourm, Plant Oily. FL 33566 Run:7.610 a Jan 292015 Pont: 7.610 a Jan 292015 MTek InEUstng %the Jul 2621D1252016 Pagel
ID:oB3FwmhkmDOkA20AOiCOM?yu7CB-phmF WSg7cDUDw_n61 xSOLnrgLVrtutlillbUHryu5CO
-14-0 7-0-0 13-0-0 20-0-0
1-0-0 7-0-0 6-0-0 7-0-0
n
5x6 =
3
5x6 =
Scale-1:34.6
3x8 _ 2x4 11 '"" - 2x4 11 ""� -
Plate Offsets (X Y)-
(3:0-3-0,0-2-71 14:0-3-0 0-2-71
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL
in
(loc)
Vdefl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.85
Vert(L-)
-0.12
8-12
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.63
Vert(TQ
-0.19
8-12
>999
240
BCLL 0.0 '
Rep Stress Incr NO
WB 0.17
Horz(TQ
0.04
5
n/a
We
BCDL 10.0
Code FBC2014/TPI2007
(Matdx-M)
Weight: 96 lb FT=20%
LUMBER -
TOP CHORD 2x4 SP No.2 *Except*
T2: 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 5=924/Mechanical, 2=991/0-8-0 (min. 0-1-8)
Max Hom 2=105(LC 16)
Max UpFft5=424(LC 13), 2= 473(LC 12)
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-4-4 oc purlins.
BOT CHORD Rigid ceiling directly applied or 5-9-12 o : bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation uide.
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-13= 1701/1212, 2-3 1941/1606, 3-4_ 1697/1545, 4-5=1943/1607
BOT CHORD 2-14=-1211/1607, 2-8=1249/1636, 7-8=-1238/1617, 6-7--1238/1617, 5-6=-1249/1636
WEBS 3-8=-257/453, 4-6=-263/457
NOTES• (9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces S MW FRS for reactions shown; Lumber DOL-1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 pet bottom chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Refer to girders) for truss to truss Connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 10011b uplift at joint(s) except at=lb) 5=424,
2=473.
8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9)'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
1) Dead +Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
�. RT :'ir, �4p
�Y9�",`
Uniform Loads (plo
,�00� .`BENS
J Q'•: �, tc •••
Vert:1-2=-54, 2-13= 14, 3-13=-54, 3-4= 54, 4-5=-54, 2-8=-20, 6-8=-80, 5-6=-20
.o STATE OF
�0,eZ �ORIDo' �'�g¢:
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016
Job ru1
rusa I ype Qty Ply
U8709 - Sturgell Res,
848709 T06
Hip 1 1
648709018
Job Reference (optional)
Builders Fit S uroe, Plant Gty, FL M65
5-7-8 30.8 1-0-0 1-0-0
3x4 =
3x4 =
4 5
5x6 — T2
3
6.00 F12 2N4 II
2
1
1
'� B1
11 10
3xs 2x4 11 4xlOMT20HS=
3-0-8 5-11-8
Scale:aw" v
Sx6 =
6
2x4 11
7
T3 b
4
8
�a
9
2x4 II 3x8
Plate Offsets (X Y)—
f4:0.2-0 0-2-81 I5:0-2-0 0-2-81, [8:0.4-0
0-1-31
LOADING lost)
SPACING- 2-0-0
CSI.
DEFL
in
(too)
Well
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.56
Vert(LL)
0.42
9-11
>555
360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.80
Vert(TL)
-0.54
9-11
>433
240
MT20HS
187/143
BCLL 0.0 '
Rep Stress Incr NO
WB 0.99
Hom(TL)
0.04
8
n1a
n1a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Weight: 93 Ib
FT = 20
LUMBER -
TOP CHORD 2x4 SP M 31 'Except'
T2: 2x4 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 1-984/04-0 (min. 0-1-8), 8=969/Mechanical
Max Ho¢ 1=102(LC 8)
Max Upliftl= 478(LC 12). 8= 473(LC 13)
BRACING -
TOP CHORD Structural wood sheathing directly applied or 4-8-12 oc purlins.
BOT CHORD Rigid ceiling directly applied or 5-7-7 be bracing.
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
FORCES. (lb) - Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2--2021/1675, 2-3=-1670/1536, 3-4=482/647, 4-5=-575/764, 5-6= 485/651,
6-7=-1666/1532, 7-8--2016/1670
BOT CHORD 1-11=-1557/1705, 10-11=-1289/1660, 9-10=-1289/1660, 8-9= 1289/1660
WEBS 2-11=-330/570, 7-9=-327/565, 3-6— 2528/2261
NOTES- (10)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd-132mph; TCDL=4.2psf; BCDL=3.Opsf; h=1511; Cat. II; Exp C; Encl., GCpi=0.18;
MW FRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 last bottom chord live load nonconcurrent with any other live loads.
6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=478,
8=473.
9) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
10) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building Is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.' ,,d BEAT W. �Y44�q
LOAD CASE(S) Standard rJ Q0.�tCENgF;9!`��
1) Dead+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (ply
Vert: 14=-54, 4-5=-54, 5-8=-54, 11-12=-20, 9-11=-80, 8-9=-20It
V.
STATE OF
GLLAA
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559 08/25/2016
Job nlsa
Iruss lype 0Y-_- Ply
M8709-Stu,ell Rex
M8709 T07
Common 1 1
8487ON19
Job Reference (oolional)
Builders RSlSource, Plant City, FLM566
6.00 12
20 II
k+:F
3x4 =
129 10
3x6 G 2x4 11 4x10 MT20HS=
axe =
5
2ca II
6
2xa 11 3x8
Scale =1:335
E
Plate Oftsels (X1)--
[4:0-2-0,Edpe117:0-1-0 Edge]
LOADING (pso
SPACING- 2-0-0
CSI.
DEFL
in
(loc)
Vdefl
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.56
Vert(LL)
0.44
8-10
>539
360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.79
Vert(TL)
-0.56
8-10
>420
240
MT20HS
1871143
BCLL 0.0 '
Rep Stress [nor NO
WB 0.88
Horz(fl.)
0.04
7
n/a
n/a
BCDL 10.0
Code FBC2014/fP12007
(Matrix-M)
Weight: 94 lb
FT=20%
LUMBER -
TOP CHORD 2x4 SP M 31
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 1=984/0-4-0 (min. 0-1-8), 7=969/Mechanical
Max Horz 1=-113(LC 8)
Max Upliftl=-486(LC 12), 7=-481(LC 13)
BRACING -
TOP CHORD Structural wood sheathing directly applied Or 4-B-3 oc pur ins.
BOT CHORD Rigid ceiling directly applied or 5-7-2 oc bracing.
M' ek recommends that Stabilizers and required cross bracing
be installed during Wss erection, in accordance with Stabilizer
Installation aide.
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 1-2--2022/1681, 2-3--1671/1542, 3-4= 294/428, 4-5=-298/432, 5-6=-1666/1539,
6-7=-2017/1677
BOT CHORD 1-10= 1602(1760, 9-10=1293/1659, 8-9=-1293/1659, 7-8— 1293/1659
WEBS 2-10=-330/573, 6-8=-328/567, 3-5=2254/2053
NOTES (9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL-3.Opsf; h-15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MW FRS (envelope) and C-C Extedor(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) All plates are MT20 plates unless otherwise Indicated.
4) This truss has been designed for a 10.0 pat bottom chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100Ito uplift at joint(s) except (jt=Ib) 1=486,
7=481.
8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9)'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.° --,�
STATE OF
SryO g.tk-.'DLORIOP
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pll)
Vert: 1-4=-54, 4-7= 54, 10-11=-201 B-10=-801 7-8=-20
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559
08/25/2016
Girder
Scale =193.1
4x6 II
Io
3x6 II 7x10 = 2x4 II
5-SS 9-11-4 14-53 19-11-4
5-5-5 4-5-15 45-15 Sbl �
Plate Offsets (X YI--
(1:0-1-11 0-1-81 f5:0-0-11 Edael f7:0-5-0 0-4-81 f8:0-4-4 0-1-8)
LOADING fast)
SPACING- 2-0-0
CSI.
DEFL
in
(too)
I/deb
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.68
Vert(LL)
0.19
6-7
>999
360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.53
Vert(TL)
-0.32
6-7
>745
240
MT20HS
187/143
BCLL 0.0
Rep Stress Incr NO
WB 0.60
HOrz(TL)
0.07
5
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matdx)
Weight: 217 Ito
FT = 20
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x6 SP M 26
WEBS 2x4 SP No.3 *Except*
W3: 2x4 SP No.2
REACTIONS. (lb/size) 1=574810-7-4 (min. 0-3-6), 5=3659/Mechanical
Max Horz 1= 110(LC 4)
Max Upliftl= 2836(LC 8), 5=-2013(LC 9)
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-5-10 oc puriins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD 1-2=-9034/4529, 2-3= 6307/3408. 3-4=-6303/3403, 4-5=-7975/4407
BOT CHORD 1-9=4032/7962, 9-10=-4032f7962, 10-11=-4032f7962, 8-11=-4032/7962, 8-12= 4032f7962,
12-13=-403217962,7-13=-4032/7962,7-14--3856/7073,14-15=-3856f7073, 6-15=-3856/7073,
5-6=-3856/7073
WEBS 3-7--2872/5345, 4-7=-173911228, 4-6= 849/1378, 2-7= 2783/1317, 2-8=1022/2530
NOTES- (12)
1) 2-ply truss to be connected together with 1 Old (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-6-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL-3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL-1.60
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
7)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members. 'OpttOtirk"s
8) Refer to girder(s) for truss to truss connections. �.0 ;?IT W, !,xi,
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except (jt=Ib) 1=284ro0E h'q �••
5=2013. 2 4F JC£NSF ;�! •i
10)'Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1017 lb down and 482 lb up # •'.
0-10-8, 1017 lb down and 473 to up at 2-10-8, 1008 Ito down and 455 Ito up at 4-10-8, 1005 Ib down and 476 lb up at 6-10-8, 1025 Ib 1y-,�'}�I �. 1 ,
down and 503 It, up at 8-10-8, and 10051b down and 593 Ito up at 10-10-8, and 1901 Ib down and 1282 lb up at 12-9-12 on bots "ri—fl•� r
chord. The design/selection of such connection device(s) is the responsibility of others. % ,e'. STATE OF
12) "This manufactured product is designed as an individual building component. The suitability and use of this component for any •• 9 •.F • ;
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.' y60k. %.; Oslo .. �0.
LOAD CASE(S) Standard
Continued on page 2
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559 08/25/2016
Job fuss
was ype ty y
648109-SNrgell Res.
TOB
Common Giber 1
M87648]09
2
Job Reference
ence (optional)
bunoem rusrSour ,ram wry, rLJ bb
nun: r.Um s Jan ZU ZU1 b rnnc LGI U s JW[ eU]0 M 1 e61nausp S, Inc. l ue JUI Zb 21:01272016 Pagget
ID:oB3Fw hkmDOkA20AOiCOM?yu7CB-m4uOx8iN8gkx9HxV8MUsOCx2TJYxMgU?D24aMjyuSCM
LOAD CASE(S) Standard
1) Dead + Root Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plq
Vert: 1-3=-54, 3-5= 54, 1-5=-20
Concentrated Loads (lb)
Vert: 9=-1017(B)10=-1017(B) 11=1008(B)12= 1005(B)13_ 1005(B) 14= 1005(B)15=-1901(8)
STATE OF
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016
/U-14 14U-e 2e-11-2 LbU-e
TON41 1 6-01-2 6-11-2 7-0-14
Scale-1.46.4
34= 3A— 5x6-=. - 3x4_— — _.3x6'
1 11 12 13 2 14 15 16 3 17 18 19 4 20 21 22 5
23 24 25
26 27 2B 29
30 31
32 33 34
10
9 8
7 6
3x6 11
3x6 = 5x8 =
3x6 = 3x6 II
7-0-14
14-0-0
20-11.2
28-0-0
7-0-14
E71-2
6-11-2
7-0-14
Plate Offsets (X,Y)--
(3:0-3-0,0-3-01 f8:0-4-0,0-3-01
LOADING (psf)
SPACING- 2-0-0
CSL
DEFL-
in
floc)
Vdefi
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.61
Vert(LL)
0.19
8
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.59
Vert(TL)
-0.29
7-8
>999
240
BCLL 0.0 '
Rep Stress Incr NO
WB 0.62
Horz(TL)
0.04
6
n1a
n/a
BCDL 10.0
Code FBC2014rrP12007
(Matrix)
Weight: 303 lb FT=20%
LUMBER -
TOP CHORD 2x4 SP No.2
SOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 1 0=1 912/Mechanical, 6=1 921 /Mechanical
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-11-4 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 9-2-3 oc bracing.
Max Upliftl0= 1261(LC 4). 6=-1262(LC 4)
FORCES. Ile) - Max. CompJMax. Ten. - All tomes 250 (Ib) or less except when shown.
TOP CHORD 1-10= 1783/1288, 1-11=-2954/1946, 11-12 2954/1946, 12-13=.2954/1946, 2-13=-2954/1946, 2-14=-3848/2533,
14-15=-3848/2533,15-16= 3848/2533,3.16— 3848/2533,3-17=-3848/2533, 17-18= 3848/2533,18-19=3848/2533,
4-19=-3848/2533, 4.20— 2962/1947, 20-21=-2962/1947, 21-22--2962/1947, 5-22=-2962/1947, 5-6— 1789/1290
BOT CHORD 9-26=-1946/2954, 26-27=-1946/2954, 27-28=-1946/2954, 8-28=-1946/2954, 8-29=-1947/2962, 29-30= 1947/2962,
30-31=-1947/2962, 7-31--1947/2962
WEBS 1-9=-2136/3243,2-9= 1190/1070, 2-8=-660/1005,3-8— 647/674, 4-8= 658/995, 4-7= 1189/1072,5-7=-2138/3252
NOTES- (11)
1) 2-ply truss to be connected together with 1 Od (0.131 "x3') nails as follows:
Top chords connected as follows: 2x4 - 1 new at 0-9-0 oc.
Bottom chords connected as follows: 2x4 - 1 now at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 mw at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (5) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd-132mph; TCDL=4.2psf; BCDL=3.Opsf; h=151t; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
4) Provide adequate drainage to prevent water pending.
5) This truss has been designed for a 10.0 pat bottom chord live load nonconcurrent with any other live loads.
6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) except 0=11c) 10-1261
, 6=1262.
9)'Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 'Jd
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 108 lb down and 138 lb up at I
, 108 to down and 138 Ib up at 3-0-0, 108 lb down and 138 lb up at 5-0-0, 108 lb down and 138 lb up at 7-0-0, 108 to down and jj9Bib
up at 9-0-0, 108 lb down and 138 It, up at 11-0-0, 1081b down and 1381b up at 13-0-0, 1081b down and 1381b up at 15-0-0, 103 lb
down and 138 lb up at 17-0-0, 108 lb down and 138 lb up at 19-0-0, 108 lb down and 138 lb up at 21-0-0, 108 lb down and 1387b11f;
at 23-0-0, and 108 It,down and 138 lb up at 25-0-0, and 10816 down and 138 lb up at 27-0.0 on top chord, and 65 lb down aneIM
up at 1-0-0, 65 It, down and 3 lb up at 3-0-0, 65 lb down and 3lb up at 5-0-0, 651b down and 3 lb up at 7-0-0, 65 to down and b ,
at 9-0-0, 65 lb down and 3 Ito up at 11-0-0, 65 lb down and 3 Ib up at 13-0-0, 65 fib down and 3 lb up at 15-0-0, 65 lb down and
at 17-0-0, 66 to down and 3 lb up at 19-0-0, 66 lb down and 3Ib up at 21-0-0, 66 lb down and 3 lb up at 23-0-0, and 66 lb down a
lb up at 25-0-0, and 66 lb down and 3lb up at 27-0-0 on bottom chord. The designtselection of such connection device(s) is the •y1
responsibility of others.
Continued on page 2
W.
�" djj
STATE OF - _
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559 08/25/2016
11) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the
building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
1) Dead+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
uniform Loads (plf)
Vert: 1-5=-54, 6-10=-20
Concentrated Loads (Ib)
--- Vert: 9=-40(B) 2=-87(B) 4--BB(B) 7= 41(B) 11--87(B)-12= 87(B) 13=-87(B) 14=-87(B) 15=-87(13)16=-87(B) 17=-87(8) 18— 87(B) 19=-88(B)20=-88(B) 21=-88(B)
22=-88(B)23=-40(B)24=-40(B)25=40(B) 26=40(B)27=-40(B)28=-40(B)29=-40(B) 30--40(B) 31--41 (B) 32=-41 (B) 33=-41(B) 34=-41(B)
J••Q�.��GENyF,9l�•�
* : ��Cw '
�44,, STATE OP
�40"$c„ :�y0At0
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016
3ou-- Pa um ype Dty —Py 8467o9-SWrgell Res.
848709 T10 Flat 1 1 848709022
Jab Reference (optional)
auJtlers FvsSource, Pant City. FL33566 Run: ].610 s Jan 292015 PrinC ].610 s Jan 29 2016 MTek lntlustries, Inc. Tue Jui 26 21U129 2016 Pag5e 1
ID:oB3FwmhkmDOkA20AOiCOM?yu7CB-iS?mLpjegS_fObStGn WKVde0Nr7E_gbklgMZhOcyuSCK
3x6 =
--4 6-11-2 704-0 &11 I
3x4 =
516 =
3x4 =
Stale-1.46.4
3x8 =
10 e u r 6
3x5 II 3x6 = 5x8 = 3x6 = 3x6 II
7-0-14 14-0-0 20-11-2 I 2a-0-0
7-0-14 6-11-2 6-11-2
Plate Offsets (X,Y).-
(3:0-3-0 0-3-01 f8:0-4-0,0-3-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL
in
(fee)
Weil
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.75
Vert(LL)
0.13
8
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.55
Vert(TL)
-0.22
8-9
>999
-240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.55
Hom(TL)
0.04
6
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matdx)
Weight: 162 Ib FT=20%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
REACTIONS. (Ib/size) 10=1025/Mechanical, 6=1025/Mechanical
Max Upliftl0= 573(LC 8), 6=573(LC 8)
BRACING -
TOP CHORD
BOTCHORD
WEBS
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-10= 1076/950,1-2=-1381/1135,2-3=-1795/1475,34=-1795/1475,4-5=-1381/1135,
5-6=-1076/950
BOTCHORD 8-9=-1135/1381, 7-f 1135/1381
WEBS 1-9=-1331/1619, 2-9=-7437782, 2-8=-407/496, 3-8=411/485, 4-8=-407/496, 4-7--743/782,
5-7=-1331/1619
Structural wood sheathing directly applied or 4-0-9 oc purlins, except
end ver8cals.
Rigid ceiling directly applied or 5-6-9 oc bracing.
1 Row at midpt 1-9.5-7
M7ek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES- (8)
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2pst BCDL=3.Opsf; h-150; Cat. II; Exit C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL-1.60 plate grip
DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 It, uplift at joint(s) except (jt=lb) 10-573,
6=573.
7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) This manufactured product is designed as an individual building component. The suitability and use of this component for any particula,4�������4Tpzj
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.' d
LOAD CASE(S) Standard ,a•Q.O.��GENgF,9l���
* , STATE Op� "
• :2
YORIO?.�x��J4
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559 08/25/2016
Job rus5
inuss type
848709-Sturgell Res
848709 Tlt
Roof Special 1 1
8487090M
Job Reference tional
Bullclers FlrstSource, Plant City, FL 33566 Run: 7.610 a Jan 292015 PrinI:7.610 s Jan 292m6 NGTek Ndustries, Inc Tue Ju126 219129 2016 Page 1
I D:oB3FwmhkmDOkA20AOiCOM4yu7CB-iS?mLpjegS_fOb5tGn WKVdOKa7Dlq WdIgMZhOcyuSCK
7-8.7 15-3-1 22-8-0 28-0-0
7-8-7 1 7811 I 7 49 1 5-0-0
xs:c
3x4.= 4x6 = 2.4 II
516 = 6.00112
Scale =1:46.4
11
12 13 11 14 10 9 15 a 7
3x6 II 3,6 = 3x4 = 3x8 = 3x4 = 3x6 II
rl
P
Plate Offsets KY)--
13:0-3-0 Edgel 15:0-4-0 0-2.81
LOADING (psf)
SPACING. 2-0-0
CSI.
DEFL
in (loc)
Well
L/d
PLATES GRIP
TOLL 20.0
Plate Grip DOL 1.25
TO 0.96
Ved(LL)
-0.0911-12
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.60
Vert(TL)
-0.2411-12
>999
240
SCLL 0.0 '
Rep Stress Incr YES
WB 0.88
Horz(fL)
0.03 7
n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix)
Weight: 168 lb FT=20%
LUMBER -
TOP CHORD 2x4 SP No.2
SOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING-
TOPCHORD
BOTCHORD
WEBS
REACTIONS. (lb/size) 12=1025/Mechanical, 7=1025/Mechanical
Max Horz 12= 145(LC 13)
Max Upliftl 2=-581 (LC 8), 7=-483(LC 8)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 1-12=-1158(990, 1-2= 1325/1043, 2-3=1615/1322, 3-4_ 1615/1322, 4-5=-1615/1321,
'5-6_ 11511863, 6-7--1199/938
BOT CHORD 11-14--812/1265, 10-14=-812/1265, 9-10=-812/1265, 9-15=-665/968, 8-15= 665/968
WEBS 1-11=-126811610, 2-11=-718/805, 2-9=346/359;4-9=483/569, 5-9=-532f733,
5-8--341/405, 6-8=-714/1076
Structural wood sheathing directly applied or 3-9-3 oc purlins, except
end verticals.
Rigid ceiling directly applied or 6-6.6 oc bracing.
1 Row at midpt 1-11
Mi rek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES- (8)
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL-3.Opsf; 11=151t; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL-1.60
2) Provide adequate drainage to prevent water pending.
3) This truss has been designed for a 10.0 pat bottom chord live load nonconcument with any other live loads.
4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL=10.Opsf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except 61-4b) 12=581.
7=483.
7)'Semi-rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any partictlJ�lp
building is the responsibility of the building designer per ANSI 7P11 as referenced by the building code." A"?
LOAD CASE(S) Standard Z -
r * , STATE OF r
i
1y�.ck_:,tO........xP��
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016
848709
am
3.e a 3x6 =
3x4 = 4x6 = 2x4 11
2x4 II
5.6 =
5x8 =
7-6-4 14-H 20-8-0 28-0-0
7-6-4 7-2-12 5-11-0 74
Scale -1:472
7
3x6 II
Plate Offsets (X.Y)--
13:0-3-0 Edoel 15:0-3-8 0-2-41 f6:Edoe
0-1-121
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL
in floc)
VdeO
Ud
PLATES GRIP
TCLL 20.0
Plate Gdp DOL 1.25
TC 0.92
Ved(LL)
0.09 10-11
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.63
Ved(TL)
-0.2410-11
>999
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.70
Horz(TL)
0.04 7
We
We
BCDL 10.0
Code FBC2014/TP12007
(Matrix)
Weight: 180 lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2 *Except*
TOP CHORD
T3:2x4 SP No.t
BOT CHORD 2x4 SP No.2 *Except*
BOT CHORD
B2: 2x4 SP No.3
WEBS 2x4 SP No.3 *Except'
WEBS
W 7: 2x4 SP No.2
REACTIONS. (lb/size) 12=1025/Mechanical, 7=1025/Mechanical
Max Horz 12=201(LC 13)
Max Uplift12=578(LC 8), 7=-455(LC 8)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 1-12=-1150/1000,1-2--1292/1042, 2-3— 1559/1336,3-4=-155911336, 4-5=-154511324,
5-6=-1194/938, 6-7=-1116/947
BOT CHORD 12-13=-94/299, 11-13= 94/299, 11-14=-723/1208,10-14=-723/1208, 4-10= 397/463
WEBS 1-11= 128011585, 2-11=-709/825, 2-10= 367/334,8-10=-626/936, 5-10=-458/680,
5-8=386/404, 6.8=-634/964
Structural wood sheathing directly applied or 4-2-3 oc purlins, except
end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-11-0 oc bracing: 10-11.
1 Row at midpt 1-11
M7ek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES- (8)
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL-1.60 plate grip
DOL=1.60
2) Provide adequate drainage to prevent water pending.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL-10.Opsf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except (jt=lb) 12=578,
7=456.
7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used In the analysis and design of this truss. ���000 A"""
8) This manufactured product is designed as an individual building component The suitability and use of this component for any parb'�1V1
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.' Ar r
LOAD CASE(S) Standard
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, Fl 33559
W.
• STATE OF
,•e,
0A, : 4i0R10y' �x@�A
08/25/2016
Job Truss I was I ype y 848709-Sturgell Res.
M709 T13 Hip 1 1 MB709025
Job Reference (optional)
guilders Rrst9ource, Plant City, FL 33566 Run: 7.510 s Jan 29 2015 Pnnu 7.610 s Jan 29 2015 Unrek Industries, Inc. Tue Jul 26 21D1:30 2016 Page 1
IDmB3FwmhkmDOkA20AOiCOM?yu7CB-AfZSZ9kG016W01f4gUIZ2rZVfW WVZ_oRvOJFy2yu5CJ
5x
1 icaw iaro-u 1 id -d-u <o-U-e �ea-u-u
7-M-8 4.9=1 2-1-0 3-11-0 7-4-7 1-11-9
ac4 11
46 % 3x4 II 5,6 =
10 9 8
214 11 3x8 = 6x8 =
7-10-12 12$-0 14-9-0 1&8-0 28-0-0
7-10-12 4-9i 2-1-0 1 3-11-0 gd-n
Scale: 1/4'=l'
Plate Offsets (XY)—
f3:0-3-0 Edgel 15:0-3-e 0-2-41
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL
in
floc)
Well
Ud
PLATES GRIP
TOLL 20.0
Plate Grip DOL 1.25
TC 0.94
Vert(LL)
0.24
1-12
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.76
Vert(TL)
-0.53
8-9
>631
240
BCLL 0.0
Rep Stress Incr YES
WB 0.82
HOrz(TL)
0.08
8
n/a
n/a
BCDL 10.0
Code FBC2014rrP12007
(Matrix)
Weight: 1651b FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 *Except* TOP CHORD
T1: 2x4 SP No.1
BOT CHORD 2x4 SP No.2 *Except* BOT CHORD
B2: 2x4 SP No.3
WEBS 2x4 SP No.3
WEDGE
Lett: 2x4 SP No.3
REACTIONS. (lb/size) 1=1028/Mechanical, 8=1028/Mechanical
Max Horz 1=203(LC 12)
Max Upliftl =-471 (LC 12), 8=-435(LC 13)
FORCES. (Ib) - Max. CompJMax. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2013/1657, 2-3=-1401/1299, 3-4= 1246/1252, 4-5=-1271/1275, 5-6= 1243/1103
BOT CHORD 1-12=-1441/1706, 11-12=-1441/1706, 4-11= 245/322, 8-9=-561/592
WEBS 2-12=-22/354, 2-11= 658/693, 9-11=-708/1032, 5-11= 288/401, 5-9=-288/315,
6-9=-177/441. 6-8=-1347/1357
Structural wood sheathing directly applied or 2-2-0 oc purlins, except
end verticals.
Rigid ceiling directly applied or 3-1-1 oc bracing.
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES- (9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; VuIt=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. 11; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 pat bottom chord live load nonconcument with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=471,
8=435. �iilmjn"
8) "Semi-dgid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. SAS W. r,
9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any part•i
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." Q."�,lCEN30:.;(�GS
LOAD CASE(S) Standard
• STATE OF -
i'�•r
LORIDP �a@� 0
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559 08/25/2016
M8709
3x4 = 3x8 II
6.00 12 3x4 a
2x4 11
12 11 10 9
2x4 II 5xa = 3x6 II
Ism
>-10.12 lb3-0 1b60 168-pp ]8-00
61--0 11-0 j 4114 I 6b13
.11�
Scale-1:54.4
Plate Offsets (X,Y)--
14:0-2-0,0-0451. f6:0-2-0,Edgel.
[8:Edge.0-1-12] 113:0-2-8 0-2-81
LOADING (pat)
SPACING- 2-0-0
CSI.
DEFL
in (too)
Well
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.88
Vert(L-)
0.20 1-14
>999
360
- MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.79
Vert(TL)
-0.3513-14
>944
240
BCLL 0.0 '
Rep Stress Incr YES
W B 0.84
HOrz(TL)
0.07 9
We
We
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
Weight: 163 lb FT-20%
LUMBER -
TOP CHORD 2x4 SP N0.2 *Except*
T1: 2x4 SP No.1
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
WEDGE
Left: 20 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 3-5-8 oc pudins, except
end verticals.
BOT CHORD
Rigid ceiling directly applied or 3-7-4 oc bracing.
WEBS
1 Row at midpt 2-13
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (lb/size) 1=1035/Mechanical, 9=1037/Mechanical
Max Horz 1-223(LC 12)
Max Upliftl= 485(LC 12), 9=-453(LC 13)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2093/1710, 2-3=-1345/1220, 3-4=-1265/1243, 4-5= 1163/1222, 5-6= 1147/1208,
6-7= 1308/1252,7-8--1212/1040,8-9=-1158/1036
BOT CHORD 1-14=1503/1781, 13-14=-1503/1781
WEBS 2-14=0/373, 2-13--851/884, 7-10= 469/528, 8-10=-822/1054, 5-13=-577/674,
10-13— 785/981
NOTES (9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL-4.2psh BCDL=3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 vide will fit
between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (It=lb) 1=485,
9=453.
8) "Seml-rigid pitchbreaks with fixed heels' Member end fixity model was used In the analysis and design of this truss.
9)'This manufactured product is designed as an individual building component. The suitability and use of this component for any partic8laf
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.'
LOAD CASE(S) Standard
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559
T W,
STATE OF •,•Q
P•"'OV 4
08/25/2016
JOD Truss
I was I ype
848]09-Sturgell Res.
848709 T15
Roof Special 1 1
84870902]
Job Reference o tional
Builders HstSource, Plant City, FL 33566
5x
6.00 12
7m,
US =
10
20 II
Sxe =
7-10-12 14-9-0
]-10-12 6104 51 I 2
5--1156-0
7
3x6 II
Stale =1:55.0
Plate Offsets (X,Y)--
f3:0-3-0 Ed0e1 f11:0-2-8 0-2-BI
LOADING (psQ
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
Vdefl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.94
Vert(LL)
0.19 1-12
>999
360
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.79
Vert(TL)
-0.34 11-12
>975
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.98
Horz(TL)
0.07 7
rda
n/a
.
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
Weight: 1641to FT=20%
LUMBER -
TOP CHORD 2x4 SP N0.2 *Except*
TI: 2x4 SP No.t
SOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3 *Except*
W3: 2x4 SP No.2
WEDGE
Left: 2x4 SP No.3
REACTIONS. (lb/size) 1=1035/Mechanical, 7=1037/Mechanical
Max Horz 1=233(LC 12)
Max Upliftl= 491(LC 12), 7=-462(LC 13)
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc purlins, except
end verticals.
BOT CHORD
Rigid ceiling directly applied or 3-8-6 oc bracing.
WEBS
1 Row at midpt 2-11
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
FORCES. (lb) - Max. CompJMax. Ten. -All forces 2,50 (lb) or less except when shown.
TOP CHORD 1-2=-2101/1733, 2-3=-1343/1218, 34-1255/1245, 4-5= 1309/1258, 5-6= 1223/1054,
6-7= 1163/1043
BOT CHORD 1-12= 1528/1801, 11-12=-1528/1801
WEBS 2-12=0/372, 2-11=-889/932, 5-8= 480/541, 6-6=-646/1073, 4-11=-631017, 8-11=-807/997
NOTES• (8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi-0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrenl with any other live loads.
4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) except (t=Ib) 1=491,
7-462.
7)'Semi-rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
8)'fhis manufactured product is designed as an individual building component. The suitability and use of this component for any particul
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.' ��'�
LOAD CASE(5) Standard
STATE OF
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, Fl 33559 08/25/2016
Job Inuss
I Was; I ype
U8709 - Sturgell Res.
848709 T16
�Ply
Roof Special 3 7
848709028
Job Reference (optional)
Builders FirsiSource, Plant City, R-33566
R
5x6 =
6.00 Fl2
11 10 9 8 7
46 = 2x4 II 3x4 ax8 = 2x4 11 3x6 =
7-10-13 15.8-0 23-54 27 "o
7-10-13 7-9-3 1 7-9-0 4-3-12
16
N
Scale -1S1.4
Plate Offsets (XY)--
f1:0-0-0,0-0-141, 13:0-3-0,Edae1
16:0.5-8,Edce1
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL
in (loc)
Vdefl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.85
Veri(LL)
0.11 11-15
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.65
Ved(TL)
-0.24 8-9
>999
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.75
Horz(TL)
0.08 16
n1a
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix-M)
Weight: 148 lb FT=20%
LUMBER -
TOP CHORD 2x4 SP No.1 'Except'
T2: 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3 *Except*
W 5: 2x4 SP No.2
OTHERS 2x6 SP No.2
WEDGE
Left: 2x4 SP No.3
REACTIONS. (lb/size) 1=1019/Mechanical, 16=990/0-5-0 (min. 0-1-8)
Max Horz 1=234(LC 12)
Max Upliftl=-489(LC 12), 16=-443(LC 13)
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 3-11-8 oc purlins, except
end verticals.
BOT CHORD
Rigid ceiling directly applied or 4-6-3 oc bracing.
WEBS
1 Row at midpt 2-9.5-9
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD 1-2=-2023/1700, 2-3--1307/1185, 3-4= 1223/1212, 4-5=-130211204, 7-12=-873/1040,
6-12=-873/1040
BOT CHORD 1-11=-1527/1752, 10-11=-1527/1752, 9-10=-1527/1752, 8-9=-933/1094, 7-8=-933/1094
WEBS 2-11-01312, 2-9=-850/917, 4-9=-499/614, 5.7--1344/1154
NOTES (9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10: Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL-3.Opsh h=151t; Cat. II; Exp C; Encl., GCpi=0.18;
MW FRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
4)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Bearing at joints) 16 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
7) Provide mechanical Connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jl=lb)
16=443.
8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.'
LOAD CASE(S) Standard
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559
08/25/2016
ion Imm
1russ type ly
848709-9Mgell Res.
84B709 T17
lely
Roof pedal 1 1
MB709029
Job Reference (optional)
aullders Rrst9oorce, Plant City, FL 33566
3x6 It
a 00F1 —2
Sx6 =
310-22 I 18-0-0 25.9-0 30---0
36 qB6 43112
Sale-1;60.6
Plate Offsets (X,Y)-
14:0-3-0,Edgel, 18:0-5-8,Edgel
LOADING (ps0
SPACING- 2-0-0
CSI.
DEFL
in (loc)
Vdefl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.99
Ver(LL)
-0.08 10-11
>999
360
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.62
Ven(TL)
-0.22 10-11
>999
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.78
Horz(fQ
0.05 17
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
Weight: 168 lb FT-20%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2 *Except*
B2: 2x4 SP No.3
WEBS 2x4 SP No.3 *Except'
W6:2x4 SP No.2
OTHERS 2x6 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 4-11-3 oc bracing.
WEBS
1 Row at midpt 5-11, 7-11
MI recommends that Stabilizers and required cross bracing
be installed during Wss erection, in accordance with Stabilizer
Installation aide.
REACTIONS. (Ib/size) 2=226/0-8-0 (min. 0-1-8), 15=110310-7-12 (min. 0-1-9), 17=922/0-5-0 (min. 0-1-8)
Max Horz 2=331(LC 12)
Max Uplift2=-123(LC 8), 15=-669(LC 12), 17=-420(LC 13)
Max Grav2=228(LC 25), 15=1103(LC 1). 17=922(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3= 266/161, 3-4=-1554/1293, 4-5=-1445/1297, 5-6=-1170/1084, 6-7=-1169/1093,
9-16= 801/962, 8-16=-801/962
BOT CHORD 14-15= 1302/1225, 3-14= 1244/1234, 12-13=1139/1340, 11-12— 1139/1340,
10-11=-858/1013, 9-10= 858/1013
WEBS 3-13=-105611267,5-11--517/599, 6-11=-372/482, 7-11— 1801280, 7-9=-1241/1058
NOTES- (8)
1) Unbalanced root live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL-3.Opsf; h=15ft; Cat. 11; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Extedor(2) zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL-1.60 plate grip
DOL=1.60
3) This buss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Bearing at joint(s) 17 considers parallel to grain value using ANSVfP11 angle to grain formula. Building designer should verify capacity
of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joints) except Qt=lb) 2-123,
15.669.17=420.
7) Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any par @uidr
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code' "
LOAD CASE(S) Standard
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, Fl 33559
W,
q STATE OF
08/25/2016
Jet, I run
N6S ype y
848709 - Sturgell Res.
M8709 T18
Roof Spedal 1 7
848709030
Job Reference (optional
Builders( SlS00(re, Plant City, FLW566
Se0 12
5x6 =
1
3x6 If
6.2.8 {- 10-2-12 1 18-0-0 25-9-0 30-1-0
6-2.8 4-0-0 7-9-0 7-9 4 4-3-12
Scale=1:60.6
, �y P
Plate Offsets (X Y)--
13:0-1-8,0-1-81 f4:0-3-0 Eddel (8:0-5-8 Edgel
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL
in (loc)
I/defl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.95
Vert(LL)
-0.0710-11
>999
360
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.80
Vert(TL)
-0.20 10-11
>999
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.63
Hoa(TL)
0.04 17
n/a
n/a
BCDL 10.0
Code FBC20147TP12007
(Matrix)
Weight: 1671b FT=20%
-LUMBER- - ----- — ---- ---
—BRACING-
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc pudins, except
BOT CHORD 2x4 SP N0.2 *Except*
end verticals.
B2: 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 4-8-5 oc bracing.
WEBS 2x4 SP No.3
WEBS
1 Row at micipt 5-11. 7-11
OTHERS 2x6 SP No.2
MiTek recommends that Stabilizers and required cross bracing
-
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) 2=275/0-8-0 (min. 0-1.8), 15=1134/0-8-0 (min. 0-1-10),
17-841/0-5-0 (min. 0-1-8)
Max Horz2=331(LC 12)
Max Up1ift2=-116(LC 8). 15=-681(LC 12), 17=391(LC 13)
Max Grav2=281(LC 25),15=1134(LC 1), 17=841(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3— 272/187, 3-4=1015/842, 4-5= 941/845, 5-6=-1009/935, 6-7=-10101936,
9-16=-720/874, 8-16=-720/874
BOT CHORD 14-15=-1297/1241, 3-14= 1266/1243, 12-13= 711/874, 11-12=-711/874, 10-11= 770M7,
9-10--770/917
WEBS 3-13=-961/1098,5-13=-365/474,5-11=-175/262,6-11--234/399, 7-11=-204/329,
7-9= 1124/951
NOTES (8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vu1t=170mph (3-second gust) Vasd=132mph; TCOL=4.2pst BCDL-3.Opsf; h=1511; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Extedor(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL-1.60
3) This truss has been designed for a 1Do psf bottom chord live load nonconcument with any other live loads.
4)' This tmss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Bearing at joints) 17 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verity capacity
of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) except OWb) 2=116 d
15-681,17-391. %ZOA
7)'Semi-rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss. Q
.4 '
8) `This manufactured product is designed as an individual building component. The suitability and use of this component for any palculal
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code' _ '
STATE OF
1q�'oF%.A10RID . " w4�
LOAD CASE(S) Standard
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559
W.
[IF:J%"WKIM
0 N5a
nlss I ype y
846709-Sturgell Res.
B4W09 T19
Roof Special 1 1
M8709031
Job Reference (optional)
e, Plant ciry, rrt:xlooti Hun: Atilu s Jan 292015 Print 7.910 a Jan 292015 %TeX Indushles, Inc. Tue Jul 26 21 A1:34 2016 Page 1
ID:oB3FwmhkmDOkA20AOICOM7yu7C8-2OpfPXnmU_dyVMzr3K6VChjBW8r8VrA1 geHS5pyu5CF
14-01 66--1-0 032-12 80I 25-94 30--0
140--0
3-13 7-94 7.9-4 4.3-12
6.00 12
3x6 II
5x6 =
6-11-0 I 10-2-12 18-0-0 I 25-94 30.1-0
6-11-0 n.3d3 9.03 NL2ro
Scale-1.60.6
Plate Offsets (X Y)-.
f2:0-0-12 Edge? (4:0.3-0 Edger
f8:0-5-8
Edgel
LOADING (psf)
SPACING- 2-0-0
CSL
DEFL.
in (roc)
Vdefl
Ltd
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TIC 0.95
Vert(L-)
-0.07 10-11
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.94
Vert(TL)
-0.2010-11
>999
240
BCLL 0.0
Rep Stress [nor YES
W B 0.61
HOR(TL)
0.04 17
n/a
n1a
BCDL 10.0
Code FBC2014fTP12007
(Matrix)
Weight: 167 lb FT=20%
LUMBER-
BRACIN -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc pudins, except
- BOT CHORD 2x4 SP No.2 *Except*
end verticals.
B2: 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 4-8-3 oc bracing.
WEBS 2x4 SP No.3
WEBS
1Row at midpt 5-11.7-11
OTHERS 2x6 SP No.2
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (lb/size) 2=30210-8-0 (min. 0-1-8), 15=1134/0-8-0 (min. 0-1-10),
17=814/0-5-0 (min. 0-1-8)
Max Horz 2=331(LC 12)
Max Uplift2=-114(LC 8), 15=-683(LC 12), 17=-381(LC 13)
Max Grav2=309(LC 25),15=1134(LC 1). 17-814(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-264/179, 34=-838/689, 4-5=-777/693, 5-6=-955/883, 6-7--956/885, 9-16=-692(844,
8-16=-692/844
BOT CHORD 14-15=-1284/1242, 3-14=-1264/1241, 12-13=-563f720, 11-12--563/720, 10-11=-7401885,
9-10=-740/885
WEBS 3-13= 886/1003, 5-13=455/553, 6-11= 187/373, 7-11=-217/347, 7-9=-1085/914
NOTES- (8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 710; VuIt=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL-3.Opsf; h=151t; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Bearing at joint(s) 17 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
6) Provide mechanical connection (by others) of buss to bearing plate capable of withstanding 100lb uplift atjoint(s) except Qt=Ib) 2=114, 'snunn
15=683, 17-381.
7) "Semi-dgid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. O
8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any pajuarr,••1%•XGENS.
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559
STATE OF
6�0�^ LOR{OPr����
08/25/2016
p
me9 ype y
Res
848]09 T20
20
floot Spedal 1 i
SW�848709-Sturgell
-
Job Reference (optional)
JobR Reference
Builders FtrstSeurce, Plant City, FL M566
6x8 =
3.6 = 64 = 3x8 =
18-0-0 I 7-0 0-161-00 2:7 I 3-0-0-0
Scale =159.3
Plate Offsets (X,Y)--
12:0-2-12,0-1-81, f9:0-0-0,0-0-141.
It 0:0-6-4,0-2-81
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL
in floc)
Well
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.76
Vert(LL)
-0.1613-14
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.69
Vert(TL)
-0.4213-14
>616
240
BCLL 0.0 '
Rep Stress Incr YES
INS 0.56
Horz(TL)
0.02 9
n/a
n/a
BCDL 10.0
Code FBC20147TP12007
(Matrix-M)
Weight: 175 lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2 *Except*
TOP CHORD
Structural wood sheathing directly applied or 3-8-3 oc purlins.
• T3: 2x4 SP No.1
BOT CHORD
Rigid ceiling directly applied or 5-1-10 oc bracing.
BOT CHORD 2x4 SP N0.2 *Except*
WEBS
1 Row at midpt 7-10
B2,B5:2x4 SP No.3, B6:2x6 SP No.2
MiTek recommends that Stabilizers and required cross bracing
WEBS 2x4 SP No.3
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (lb/size) 9=77510-5-0 (min. 0-1-8),2=401/0-8-0 (min. 0-1-8),15=1125/0-8-0 (min.0-1-9)
Max Horz2=320(LC 12)
Max Uplift9= 381(LC 13), 2=-153(LC 12), 15=-622(LC 12)
Max Grav9=775(LC 1), 2=412(LC 25), 15=1125(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-916/501, 6-7=318/807, 7-8=-1753/1768, 8-9=-1581/1368
BOT CHORD 2-15= 902/1254, 14-15=-1011/862, 13-14=-339/405, 8-10=-496/710, 9-10=-1128/1360
WEBS 3-15= 346/460,6-14=-1008/944,6-13=0/257,10-13=-274/501, 7-10=-1131/1077
NOTES (7)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL-1.60 plate grip
DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
4)' This truss has been designed for a live load of 20.Opsf on the bottom chard in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joints) except (It=lb) 9=381,
2=153,15=622.
6) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559
.�- OEp' h'�' "
y��GENi W9!l
STATE OF01.
�� 4
Job Inuss
I MISS ype y
848709-Sturgell Res.
848709 T21
Roof Special 3 1
B48709033
Job Reference (optional)
Builders RralSource, Plant City, PL 33566
6x8 =
9
d
3x6 = 6x8 = ax8 =
8-8-0 9Fa0 18-0-0 I 25-7-0 I 30.1-0
8-8-0 0.6- 9-10-0 7-7-0
Scale =139.3
Plate Offsets(XY)--
f2:0-2-80-1-81 f9:0-1-40-1-81 If
0:0-6-40-2-81
LOADING (psf)
SPACING- 2-0-0
CSI.
OEFL
in (loc)
I/de8
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.76
Vert(L-)
-0.1513-14
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.69
Ved(TL)
-0.3713-14
>687
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.53
Horz TL)
0.02 9
n/a
rVa
BCDL 10.0
Code FBC2014/TPI2007
(Matrix-M)
Weight: 175 lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP N0.2 *Except* TOP CHORD
T3: 2x4 SP No.1 BOT CHORD
BOTCHORD 2x4 SP N0.2*Except' WEBS
82,B5:2x4 SP No.3, B6:2x6 SP No.2
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 9=768/0-5-0 (min. 0-1-8), 2=420/0-8-0 (min. 0-1-8), 15=1114/0-6-0 (min. 0-1-9)
Max Horz2=320(LC 12)
Max Uplift9=-379(LC 13), 2=-165(LC 12), 15=-614(LC 12)
Max Grav9=768(LC 1), 2=431(LC 25), 15=1114(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1040/626, 6-7=-8031795, 7-8--1735/1753, 8.9=-1564/1353
BOT CHORD 2-15=-1092/1435, 14-15=-954/792, 13-14=-311/375, 8-10=-496/711, 9-10=-1115/1345
WEBS 3-15=369/493, 6-14=-997/942, 6-13= 6/268, 10-13=-264/487, 7-10= 1128/1074
Structural wood sheathing directly applied or 3-8-8 oc purlins
Rigid ceiling directly applied or 5-3-9 oc bracing.
1 Row at midpt 7-10
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES (7)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15tt; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Extedor(2) zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 9=379,
2=165, 15=614.
6) "Semi -rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
7)'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.'
LOAD CASE(S) Standard •J••`0ER7 W. q
II•Q� •l?GENyF,q!!ow
? * , STATEOF ,
P
so
d%
�89oc'• ;;oR�o � d`��d
yi4 S ONAL dG `••
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, Fl 33559 08/25/2016
J013 Inuss
Inuss Iypa y
Ba8709-Sturgell Res.
MB709 122
Hip 1 1
848709034
Jab Reference (optional)
tluubeld rlrsrsource, rianl ciry, rl JJabb Hun: 7.610 S Jan 29 2m5 Pony 7.610 s Jan 29 2015 KTeK Industries, Inc. rue J612b Z1:U1:J52015 Page 1
ID:oB3FwmhkmDOkA20AOICOM7yu7CB-XLNIctoPFIl06WY1 at dkluGMhXErEK5A2107eFyu5CE
19-0-0
td-0 E6i &2-0 11<-12 17-8-0-0 259-0 30a-0
li-o s-a4 zaaz 1 2 U -2-1z 1 S7d0-0 �i ,
Scale-1.60.9
3111 2X4 II
3x4
3x6 = him = 3x8 = 3z6 = 3X6 II
8.8-0 9r2i0 18-0-0 25-9-0 30-0-0
8.8-0 0 8-10-0 i %: F 4-7-0
Plate Offsets (X,Y)-.
12:0-2-8.0-1-81 P:0-2-0 Edger 19:0-2-0
Edgel 110:0-1-0 0-1-8]
114:0-1-12 0-1-81
LOADING (psf)
SPACING- 2-0-0
CS].
DEFL
in (loc)
Vdefi
Lfd
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.92
Vert(LL)
-0.1416-17
>999
360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.72
Vert(TL)
-0.2218-21
>502
240
BCLL 0.0 '
Rep Stress Incr YES
WE 0.50
Hoa(TL)
0.06 12
n/a
n/a
BCDL 10.0
Code FBC2014/rP12007
(Matrix-M)
Weight: 175 lb
FT-20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
BOT CHORD 2x4 SP No.2 *Except*
B2: 2x4 SP No.3, B5: 2x6 SP No.2
BOT CHORD
WEBS 2x4 SP No.3
WEBS
REACTIONS. (lb/size) 2=425/0-8-0 (min. 0-1-8), 12=774/Mechanical, 18-111010-6-0 (min. 0-1-9)
Max Hor42=308(LC 12)
Max Uplitt2=-176(LC 12), 12— 378(LC 13), 18=-592(1_0 12)
Max Grav2=431(LC 25), 12=774(LC 1), 18=1110(LC 1)
FORCES. (Ib) - Max. CompdMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1044/631, 6-7=-817/810, 7-8=-711/835, 8-9=-711/835, 9-10=836/797,
10-11=-771/685,11-12--884/796
BOT CHORD 2-18=-1093/1437, 17-18=-945/773, 16-17=-308/372, 15-16=-712/836, 14-15=-712/836,
13-14=-376/366,10-14--315/389
WEBS 3-18=-364/487, 10-16=-285/419, 11-13— 635f762, 8-16= 113/290, 6-16=39/307,
6-17=939/853
Structural wood sheathing directly applied or 2-2-0 oc purlins, except
end verticals.
Rigid ceiling directly applied or 5-4-10 oc bracing.
1 Row at midpt 10-16
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation quide.
NOTES- (9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsh h=15ft; Cat. 11; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL-1.60 plate grip
DOL-1.60
3) Provide adequate drainage to prevent water pending.
4) This truss has been designed for a 10.0 pat bottom chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except Ql=Ib) 2=176 X
12=378, 18=592. ���
8)'Semi-rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this buss.
9)'This manufactured product is designed as an individual building component. The suitability and use of this component for any pa Iculaf
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.' _
STATE OFQ.
y1 , . LORRIO.O'.r\����i
LOAD CASE(S) Standard
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559
08/25/2016
Joe IMSE;
iruss I ype y
M8709-SnMeli Res.
M8709 TZ3
Hip 1 7
848709035
Job Reference (optional)
rsl5ou¢e, Plant Uny, PL 33516 Run: 7.610 a Jan 29 2015 Pont: 7.510 a Jan 29 M15 KI eK Ineusbies, Inc. Tue Ju126 Z1 A1252016 Page 1
ID:oB3FwmhkmDOkA20AOiCOM?yu7CB-?oxPgCpl Obtfkg7EA18zH6pYtxdfzmyKHymZAiyuSCD
1-0-0 -5-12 1:-0 284-7 30-4-0
14
-0 66-0-0 26--0 74-7 1-11-9-5
Scale = 1:53.7
416 = _
6 6
6.00 12
F ..
_ 6x8 = 3x4 = 3x4 = 6x8 =
3.8 =
9-0-0 15-0-0 21-0-0 30-4-0
9-H I 6-0-0 6 O 9-0-0 l
Plate Offsets (X,Y)-
12:0-2-10 0-1-81 14:0-3-0,0-3-01
(6:0-3-8 0-2-41 113:0-3-8 0-3-01
LOADING (psQ
SPACING- 2-0-0
CS].
DEFL
in
(loc)
Udell
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.89
Vert(LL)
-0.14
9-10
>999
360
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.55
Vert(TL)
-0.24
2-13
>430
240
BCLL 0.0 '
Rep Stress [nor YES
W B 0.52
HOrz(TL)
0.01
9
Na
n/a
BCDL 10.0
Code FBC2014,TP12007
(Matrix)
Weight: 177 lb F7=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
BOT CHORD 2x4 SP No.2 *Except'
B2:2x4 SP M 31
BOT CHORD
WEBS 2x4 SP No.3
,
WEBS
REACTIONS. (lb/size) 2=36210-8-0 (min. 0-1-8), 13=1182/0-8-0 (min. 0-1-11),
9=759/Mechanical
Max Horz2=288(LC 12)
Max Uplifl2=-148(LC 12), 13=605(LC 12), 9=-341(LC 13)
Max Gmv2=368(LC 25), 13-1182(LC 1). 9=759(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 fib) or less except when shown.
TOP CHORD 4-5=-675/616, 5-6- 581/663, 6-7= 8751724
BOT CHORD 11-14=-377/642, 10-14--377/642, 9-10- 432/465
WEBS 3-13=-326/406, 4-13=-1013/955, 4-11=-477/693, 6-11= 274/201, 6-10=-21252,
7-10=-66/268,7-9=-1061/1055
Structural wood sheathing directly applied or 2-2-0 oc pur ins, except
end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 11-13.
1 Row at midpt 6-11
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES- (9)
1) Unbalanced root live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL-4.2psf; BCDL=3.Opst h=15tt; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 pat bottom chord live load nonconcument with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL =10.Opsf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) except 611b) 2=148,
13=605, 9=341. 0 r
8) "Semi-dgid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. d�C
9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any pa ur
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.' ,:,
LOAD CASE(S) Standard
Robert W. Wall, PE 46021
24710 State Road 54 Lut2, FI 33559
IN,
STATE OF
990,oF� ;70R10P
08/25/2016
Job TnJw
I russ I yea Vly
848709-BNs rgell Re
M5709 T24
jUtY
Hip 1 1
848709036
Job Reference (optional)
Builders FVSISOOee, Plant City, FL 33566
n
d
MiTek Industries, Inc. Tue J0126 21:01:372016 Page 1
Ypfnv?WMgiOkSICgJLhBLw4iFPT WcV6iByu5CC
Scale -1:52.8
6.00 12 46 =
3x4 = 45 =
5 6 7
_.. -
6x8 =
3x8 = 3x4 =
axe = 3x6 II
9-0-0
13-0-0
23-0-0
30.4-0
i
9-0-0
4-0%
10-0-0
7 4AO
Plate Offsets (X Y)--
12:0-2-10 0-1-81 f4:0-3-0 0-3-01 17:0-3-8
0-2-41, 18:0-3-0 0-1-81
f13:0-3-8 0-3-01
LOADING (psf)
SPACING- 2-0-0
CSL
DEFL
in floc)
Vdefl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.98
Vert(LL)
-0.2210-12
>999
360
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.67
Vert(TL)
-0.26 2-13
>399
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.45
Hor4(TL)
0.01 9
n/a
n/a
BCDL 10.0
Code FBC2014/fP12007
(Matrix)
Weight: 174 lb FT-20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
BOT CHORD 2x4 SP N0.2 *Except*
BOT CHORD
B2:2x4 SP M 31
WEBS
WEBS 2x4 SP No.3
REACTIONS. (Ito/size) 2=337/0-8-0 (min. 0-1-8). 13=1217/0-8-0 (min. 0-1-12),
9=749/Mechanical
Max Horz 2=267(LC 12)
Max Upliff2= 150(LC 12), 13=-577(LG 12). 9=-319(LC 13)
Max Grav2=343(LC 25), 13-1217(LC 1), 9=749(LC 1)
FORCES. (lb) - Max. CompJMax. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 4-5=-540/476, 5-6=-472J504, 6-7 775/750, 7-8=.892/679, 8-9=-861/727
BOT CHORD 11-12=-443/657, 11-14=443/657, 14-15=-443/657, 10-15=-443/657
WEBS 3-13=383/477, 4-13— 1079/894, 4-12=564/832, 6-12= 453/435, 8-10= 37a/677
Structural wood sheathing directly applied, except end verticals
Rigid ceiling directly applied or 6-0-0 oc bracing.
1 Row at midpt 6-12, 6-10
MlTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES- (9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Extedor(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water pending.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL=10.Opsf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except (jt=lb) 2-150,
13=577,9=319.
8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code'
.-XCEI ", ••q -vim
If • T 3�
LOAD CASE(S) Standard
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559
q, STATE OF 2
08/25/2016
Job rus5
I !Ilse I ype y
8,18709 - Sturgell Res.
M8709 7r25
Hip 1 1
M8709037
Job Reference o tional
cuueeis tauti(afW, Pisa c11y, PL as5titi RUn: 7.6105 Jan 29 2015 Pant: 7.610 Is Jan 29 2015 Well InanSMes. Inc. Ius Jul 20 21311.J/ 2UIti Y2Be 1
I D:oB3FwmhkmDOkA20AOICOM?yu7CB-T?Unl Ypfnv4 WMgiOkSfCgJLmrLxei65T Wa6i8yu5CC
-1-0-0 6-5-12 9-0-0 11-0-0 18-0-0 25-0-0 304-0
1-0-0 e-5-12 2-64 24}0 7-0-0 7-0-0 54-0
56 =
fine =
3x4 = 3x8 =
5x6 =
3x4 =
9-0-0 11-0-0 18-0-0 25-0-0 304.0
9-0-0 2-0-0 7-" 7-0-0 54-0
Scale -1:511
3x6 II
Plate Offsets_(X,Y)--
I5:0-3-0,0-2-01, 17:0-3-0,0-2-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL
in (too)
Udell
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TIC 0.68
Vert(LL)
-0.13 11-13
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.63
Vert(TL)
-0.27 2-13
>385
240
BCLL 0.0 '
Rep Stress Incr YES
W B 0.98
Horz(TL)
0.01 9
n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix)
Weight: 170 lb FT=20%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No-3 *Except*
W4: 2x4 SP No.2
BRACING-
TOPCHORD
BOT CHORD
REACTIONS. (lb/size) 2=294/0-8-0 (min. 0-1-8), 13=1278/0-8-0 (min. 0d-14), 9=731/Mechanical
Max Horz2=247(LC 12)
Max Upliff2=-143(LC 12), 13=-609(LC 9), 9--340(LC 8)
Max Grav2=299(LC 25), 13=1278(LC 1). 9=739(LC 26)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 3-4=.202/269, 4-5=-166/302, 5-6=-853/785, 6-7=853f785, 7-8=-785/613, 8-9= 844/697
BOT CHORD 11-16=-436/634, 10-16=-436/634
WEBS 3-13=398/519, 5-13=-1053/915, 5-11--695/907, 6-11=493/580, 7-10=.174/268,
8-10= 453/693
Structural wood sheathing directly applied or 5-8-15 oc pudins, except
end verticals.
Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during Wss erection, in accordance with Stabilizer
Installation guide.
NOTES (9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd-132mph; TCDL-4.2psf; BCDL=3.Opsh h=15111; Cal. 11; Exp C; Encl.. GCpi=0.18;
MWFRS (envelope) and C-C Extedor(2) zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
5)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) except 61=1b) 2=143,
13=609, 9=340.
8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9)'This manufactured product is designed as an individual building component. The suitability and use of this component for any par icu�(11
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code" _• 1
LOAD CASE(S) Standard
1v.
STATE OF -
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559 08/25/2016
Job fuss
I runs type ly
848]09-SNrgell Res.
848709 Us
Hag Hip 1 1
848709038
Job Reference (optional)
I
n rumoew,x, rwn... ....... hun: r.tilu s Jan z9 2m Pont: 7.e10 S Jan 2e 2015 M Iex Neustoes, m IYe Jul2b 21:a1:36 Z016 Page 1
I D:oB3FwmhkmDOkA20AOiCOM?yu7CB-xB2AEugHYD7Nz_HclABRNXuyLIHARa6clGFgEayuV6
-9 9-0-0 16-1-16 23-2-1 30-4-0
14-0 6-10-9 2-1-7 7-1-15 7-0-3 7-1-15
Scale -152.1
Us = - - 3x4 = 3x4 = 3x4 = — 3x6 =
axis = 3x4 = 3x4 =
30 =
3x6 II
9-0-0 i 1823-2-1 304-0
' 9-0-0 Z1e5 711 a zles I
Plate Offsets (X Y)--
f2:0-0-8 Edgel
LOADING (pso
SPACING- 2-0-0
CSI.
DEFL
in
(loc)
Vdefl
Ud
PLATES GRIP
TOLL 20.0
Plate Grip DOL 1.25
TC 0.64
Ved(LL)
-0.13
2-13
>802
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.61
Ved(TL)
-0.35
2-13
>305
240
BCLL 0.0
Rep Stress Incr YES
WB 0.93
Horz(TL)
0.02
9
n/a
n/a
BCDL 10.0
Code FBC2014/rP12007
(Matdx)
Weight: 161 lb FT=20%
LUMBER -
TOP CHORD 2x4 SP N0.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3 *Except'
W3: 2x4 SP No.2
BRACING -
TOP CHORD
BOTCHORD
WEBS
REACTIONS. (lb/size) 9=689/Mechanical, 2-216/0-8-0 (min. 0-1-8), 13=1398/0-8-0 (min. 0-1-14)
Max Horz2=283(LC 12)
Max Uplift9=-397(LC 8), 2=-117(LC 12), 13=-744(LC 9)
Max Grav9=689(1-C 1), 2-237(LC 21), 13=1398(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All fames 250 (Ib) or less except when shown.
TOP CHORD 2-3=-366/362, 3-4= 396/449, 4-5=-349/411, 5-6=-657/557, 6-7=-657/557, 7-8= 817/675,
8-9=703/648
BOT CHORD 12-13= 557/657, 11-12--557/657, 10-11=-6751817
WEBS 3-13= 383/494, 4-13--408t436.5-13— 1271/1075,5-11=-31/324,7-10=-359/472,
8-10— 777/941
Structural wood sheathing directly applied or 5-8-0 oc purlins, except
end verticals.
Rigid ceiling directly applied or 6-0-0 oc bracing.
1 Row at midpt 5-13, 7-11
M7ek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES- (8)
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsh h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces 8 MW FRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) Provide adequate drainage to prevent water pending.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
4) • This truss has been designed for a live load of 20.0psf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 9=397.
2-117, 13=744. 4ttfutaq�„
7)'Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 0C-PJ W.
8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any part! H ,•/
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.' r't •�?GEN`SF ••;� 1
LOAD CASE(S) Standard 7 ;
.,a STATE STATE OF
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016
Girder
Scale =1 S21
4X6 = 2t4 II
3x4 =
3x4 = 3x4 =
3x6 =
fi.W 12 3 4 14 5
16 5 17
6 18 19 7 20 21
22 8
2
m
01
23 13 24 25
1226 71 27
28 29 10 30 31
32 0
3x4 =
7x10 =
3x4 = 3x4 =
3x4 =
3x6 II
7-0-0 9-0-0 16-1-7
23-1-13 30-0-0
1
Mo HMO 7-1-7
l
7-0-7 7-2-3
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL
in (loc) Well L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.55
Vert(LL)
0.11 2-13 >959 360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.63
Vert(TL)
-0.25 2-13 >413 240
BCLL 0.0 '
Rep Stress Incr NO
WB 0.65
Horz(TL)
0.02 9 n/a n1a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
Weight:3101b
FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP No.2
end verticals.
WEBS 2x4 SP No.3 *Except*
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing,
Except:
W2: 2x6 SP No.2
6-0-0 oc bracing: 2-13.
REACTIONS. (lb/size) 9=1260/Mechanical, 2=58/0-8-0 (min. 0-1-8), 13=2750/0-8-0 (min. 0-1-10)
Max Horz2=227(LC 8)
Max Uplift)=-832(1-C 4), 2=-270(LC 23), 13=-1823(LC 5)
Max Grav9=1260(LC 1), 2=328(LC 15),13=2750(LC 1)
FORCES. fib) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=-510/735, 3-4=-610/911, 4-14=-609/911,14-15=-609/911, 15-16=-609/911,
5-16= 609/911,5-17=-1334/894,6-17=-1334/894,6-18=-1334/894,18-19= 1334/894,
7-19=-1334/894,7-20= 1731/1145,20-21=-1731/1145,21-22=-1731/1145, 8-22=-1731/1145,
8-9= 1137/861
BOT CHORD 2-23=-570/409, 13-23=-570/409,13-24=-894/1334, 24-25-894/1334, 12-25_ 894/1334,
12-26= 894/1334,11-26=-894/1334,11-27=-1145/1731, 27-28-1145/1731,
28-29-114511731, 10-29=1145/1731
WEBS 3-13= 692/603, 4-13= 550/624, 5-13= 2509/1673,5-11=-30/610, 7-11=-445/287,
7-10=-534/645, 8-10=-1233/1864
NOTES- (11)
1) 2-ply truss to be connected together with 1 Od (0.131 NY) nails as follows:
Top chords connected as follows: 2x4 - 1 raw at 0-9-0 oc.
Bottom chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 -2 rows staggered at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsh h=15h; Cat. 11; Exp C; Encl., GCpi=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL-1.60
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide w' I S
between the bottom chord and any other members. rS Q �1GENSF.,=� �S
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (R=lb) 9432,;•
2=270, 13-1823.
9) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used In the analysis and design of this truss. * 4 -- y�( f
STATE OF
.qqo
Continued on page 2
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559
08/25/2016
Job— - Truss ITmTypE y 848709 - Sturgell Res.
848709 T2] HaO Hip GiNer 1 2 Job Reference(optionag
Builders RrstSource, Plant City, FL 33566 Run:7.610 s Jan 29 2015 Print 7.610 a Jan 29 2015 NGTsk Indusnes, Inc. Tue Ju126 21D1:39 2016 Pag8e 2
ID:oB3FwmhkmDOkA20AOiCOM7yu7CB-PNcYSEwJWFEb7sortihvkR8T9d5A51mzw Dnlyu5CA
rry ma- III)
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 233 lb down and 326 lb up at 7-0-0, 108 Ib down and 158 Its up at 9-0-12,
108 Ib down and 158 Ito up at 11-0-12, 108 lb down and 1581b up at 13-0-12, 1081b down and 15811b up at 15-0-12, 108 Ib down and 158 lb up at 17-0-12, 108 lb down and
158 lb up at 19-0-12,108 [boom and 1581b up at 21-0-12, 108 Ib down and 15811b up at 23-0-12,108 Ib down and 158 Ib up at 25-0-12, and 108 Its down and 15811b up at
27-0-12, and 108 Its down and 1581b up at 29-0-12 on top chord, and 205 lb down and 1341b up at 7-0-0, 65 lb down and 3 Ib up at 9-0-12, 65 lb down and 3 Its up at
11-0-12, 65 lb down and 3 Ib up at 13-0-12. 65 Its down and 3 to up at 15-0-12, 65 lb down and 3 lb up at 17-0-12, 65 lb down and 3 Ib up at 19-0-12, 65 Ito down and 3 lb up
at 21-0-12, 65 Its down and 3 Its up at 23-0-12, 65 lb down and 3 Ib up at 25-0-12, and 65 lb down and 3 lb up at 27-0-12, and 65 Its down and 3 Ito up at 29-0-12 on bottom
chord. The design/selection of such connection device(s) is the responsibility of others.
11) "This manufactured product is designed as an lndividuatbuilding -component. The suitability and use of this component for any particular building is the responsibility of the
building designer per ANSI TPI 1 as referenced by the building code"
LOAD CASE(S) Standard
1) Dead+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3— 54, 3-8= 54, 2-9=-20
Concentrated Loads (lb)
Vert: 3= 171(F)13=40(F) 4_ 87(F) 7— 87(F) 10= 40(F)14=-87(F) 15=-87(F) 16=-87(F)17=-87(F) 18=-87(F) 19=-87(F) 20=-87(F) 21= 87(F) 22= 87(F) 23=-202(F)
24-40(F) 25=40(F) 26= 40(F) 27=-40(F) 28=-40(F) 29=40(F) 30= 40(F) 31=-40(F) 32=40(F)
"fY�L: j
STATE OF 'RR
All
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, Fl 33559 08/25/2016
Job Truss truss 1 ype y 648709-Sturgell Res.
848709 us Common Giber 1 2 Job Re erence (optional)
Builders FustSoume, Plant City, a 33566 Run: 7.610 s Jan 292015 Print 7.610 s Jan 29 2015 wrek Inouslries, Inc. Tue Jul 2621 D1:402016 Pagge 1
ID:oB3FwmhkmDOkA20AOiCOM?yu7CB-taAwfasX4gN5DH0?Pb&SyzESYz1VXJvCakmJTyu5C9
-1-9 -a b-f-5 9-a-u 11-1W0 16-2-0
1441 6-7-8 2-7-8 2-7-8 1 6-3-8
4n6 =
Ia
Scale-1:31.4
1i
Plate Offsets (X,Y)--
f2:0-2-10 0-1-87 (6:0-0-0 0-0-141 P:0-7.0 04-121
LOADING (pet)
SPACING- 2-0-0
CSI.
DEFL
in
floc)
Well
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.85
Vert(LL)
0.24
6-7
>867
360
MT20
2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.63
Vert(TL)
-0.48
6-7
>446
240
MT20HS
187/143
BCLL 0.0 '
Rep Stress Incr NO
WB 0.76
Hom(TL)
0.03
6
nta
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
Weight:1861b
FT=20%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x6 SP M 26
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 6=3755/0-4-0 (min. 0-2-3), 2-2495/0-8-0 (min. 0-1-8)
Max Hom2=127(LC 31)
Max Uplift6=-1928(LC 9), 2--1394(LC 8)
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-11-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=-4700/2524, 3-4--4507/2485, 4-5=4535/2492, 5-6= 4733/2543
BOT CHORD 2-8= 2231/4097, 7-8=-2231/4097, 7-9=-2169/4164, 9.10=-2169/4164, 10-11=-2169/4164, 11-12=-2169/4164,
6-12=-2169/4164
WEBS 4-7=-2202/3973, 5-7=-279/282, 3-7= 258/318
NOTES- (11)
1) 2-ply truss to be connected together with 10d (0.131 °x3') nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psh BCDL=3.Opsf; h=1511; Cat. 11; Exp C; Encl., GCpi=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL-1.60
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chard live load nonconcunent with any other live loads.
7)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 6=1928,
2=1394.
9) "Semi -rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss. �{
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1240 lb down and 852 lb up at �4
7-1-9, 669 Ib down and 417 Ib up at 9-0-12, 7191b down and 360 Ib up at 11-0-12, 729 Ib dawn and 339 Ib up at 13-0-12, and 730�5t'
down and 361 to up at 15-0-12, and 754 lb down and 398 lb up at 17-0-12 on bottom chord. The design/selection of such corm . ion
h
W,
w
decats, Is t e responsibility of others.
11) This manufactured product is designed as an individual building component. The suitability and use of this component for any �
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code' i�-`•b.•/
STATE OF
LOAD CASE(S) Standard IL•90'r�c�'�Op70?;� A4
Continued on page 2
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559
08/25/2016
Truss
rus9 Type y
648709 - Ses,01 Res.
a49]09 T26
Common Giber i
2
Job Referrence (Optional)
Plans Ucy, FL 33555
LOAD CASE(S) Standard
1) Dead+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=54, 4-6=-54, 2-6=-20
Concentrated Loads (lb)
Vert: 7=-669(B) 8=1240(B) 9= 719(B) 10=-729(B)11=-739(B) 12= 754(B)
Run: Taus Jan 292015 PnnL 7.610 s Jan 29 2015 ATek industries, Inc. Tue Jul 2621:01:402016 Page 2
ID:oB3FwmhkmDOkA20AOiCOM?yu7CB-taAwfaSX4gN5DHO?PbDwSyzESYzJvXJvCakmJTyu5C9
i MEW )
,o S STATE OF J
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016
Joe IFILISS
m5S type PITY
aIsms -Swrge Res.
949709 T29
Common 1 1
848709041
Job Reference a tional
Suilders FirstSourim, Plant City, K 33565 Hun: Lelu s Jan 29 zum rnnc .wus aan za zmo max ina a nes, inu. i ue em -u. cro cu,a rage i
ID:OB3FwmhkmDDkA20AOiCOM?yu7CB-taAwfasX4gN5DH0?PbDwSyzJvYOpveRvCakmJTyu5C9
-1-4-0 6-7-8 9-3-0 11-10-7 1B-2-0
1-0-0 6-7-8 2-7-7 2-7-7 6-3-8
I.
4x6 =
3x6 = rxm =
Scale: aw=l'
M
LOADING (psQ
TCLL 20.0
TCDL 7.0
BCLL 0.0 '
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Inter YES
Code FBC2014/rP12007
CSI.
TC 0.57
BC 0.41
INS 0.30
(Matrix-M)
DEFL in
Vert(L-) 0.09
Vert(Q -0.16
Horz(TL) 0.02
(loc) Udell Ud
7-12 >999 360
7-12 >999 240
6 We n/a
PLATES GRIP
MT20 2441190
Weight: 931b FT=20%
LUMBER.
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 4-9-11 oc puriins.
- BOT CHORD 2x6 SP No.2
BOT CHORD
Rigid ceiling directly applied or 7-6-14 oc bracing.
WEBS 2x4 SP No.3
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (lb/size) 6=67210-4.0 (min. 0-1-8),2=748/0-8-0 (min. 0-1-8)
Max Horz2=132(LC 12)
Max Uplift6=-315(LC 13). 2=370(LC 12)
FORCES. (Ib) - Max. CompJMax. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 2-13=-1090/760, 2-3=-1228/1055, 3-4=-1030/949, 4-5=-1025/945, 5-6=-1216/1046
BOT CHORD 2-14=-762/999, 2-7= 790/1019, 6-7= 879/1027
WEBS 4-7=-764/819, 5-7=-338/466, 3-7=-36B/488
NOTES- (7)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
4) *This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=11b) 6=315,
2=370.
6) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, Fl 33559
o' p�ER7 W, �q •4
4r"1ST/"GUA
STATE OF •; Q,
08/25/2016
Job russ
imss type Fy
848]09-SWrgell Res.
848709 T30
Hip 1 1
848]09042
Job Reference o tional
Builders MrslSource, Plant City, FL 33566
IM
3x4 = 36 II 314 =
3x6 = /xlu =
Scale =1 21.3
w
0
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0 '
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2014/TPI2007
CSI.
TC 0.56
BC 0.41
WB 0.25
(Matrix-M)
DEFL in
Vert(LL) 0.09
Vert(TL) -0.17
Horc(TL) 0.02
(loc) Vdefl Ltd
9-14 >999 360
9-14 >999 240
a n/a n/a
PLATES GRIP
MT20 244/190
-
Weight: 921b FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 4-8-15 oc puffins.
BOT CHORD 2x6 SP No.2
BOT CHORD
Rigid ceiling directly applied or 7-7-7 oc bracing.
WEBS 2x4 SP No.3
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (lb/size) 8=67210-4-0 (min. 0-1-8), 2=748/0-8-0 (min. 0-1-8)
Max Horz 2=124(LC 12)
Max UpliRe=-309(LC 13), 2=-364(LC42)
FORCES. (to) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-15=-1072(740, 2-3=-1215/1040, 3-4=1025/940, 4-5=-882/a42, 5-6=-882/842,
6-7=-1020/937, 7-8=-1203/1031
BOT CHORD 2-16=746/985, 2-9= 775/1006, 8-9=-906/1055
WEBS 3-9=338/458, 7-9=-308/436, 5-9=-720/775
NOTES- (8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult-170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. 11; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Extedor(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joinf(s) except (jt=lb) 8=309,
2=364.
7)'Semi-rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code"
LOAD CASE(S) Standard KEPT W.
STATE OF
ca: f4atl oA ��.R4 Q$01
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016
B48709
Hip
8
1
Builders RrstSot
1-A-I
7-0-0
r
I
4x6 =
46 =
4
3x6 = a4 It '"'- a4 11 3.6 =
Scale-1:34.0
LOADING (psf) SPACING- 2-0-0 CS]. DEFL in (loc) I/defl Ud PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0.60 Vert(LL) -0.09 7-13 >999 360 MT20 244/190
TCDL 7.0 Lumber DOL 1.25 SC 0.40 Vert(TL) -0.15 7-13 >999 240
BCLL 0.0 ' Rep Stress [nor YES W B 0.10 Horz(TL) 0.03 5 n/a n/a
BCDL 10.0 Code FBC2014/rP12007 (Matrix-M) Weight: 86 lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-6-5 oc pudins.
" BOT CHORD 2x6 SP No.2 BOT CHORD Rigid ceiling directly applied or 8-0-2 oc bracing.
WEBS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation nuide.
REACTIONS. (lb/size) 2=760/0-8-0 (min. 0-1 -8), 5=76010-8-0 (min. 0-1-8)
Max Horz 2=-88(LC 10)
Max Uplift2_ 348(LC 12), 5=-348(LC 13)
FORCES. (Ib) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-14=1077/678, 2-3= 1270/1019, 3-4=-1125/1022, 4-5=-1270/1019, 5-15=-1077/679
BOT CHORD 2-16=-644/1027, 2-9=-677/1051, 8-9=-679/1060, 7-8=-679/1060, 5-7=677/1051,
5-17=-645/1027
WEBS 3-9=-38/264, 4-7=-38/264
NOTES- (8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vu1t=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. 11; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except (jt=1b) 2=348,
5=348.
7) "Semi-dgid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8)'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
NauWp��
LOAD CASE(S) Standard-XISVJ
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559
STATE OF ; Q
i
08/25/2016
Job Truss
I mss I ype LAY Vy
848]09-SWmell Res.
M8709 M
Hip Greer 1 1
84a709044
Job Reference o lional
BuHdem FirstSource, Plant City, FL 33566
Scale=1:34.0
4.6 =
3x4 =
4x6 =
314 = 3x4 = "'- 3x4 = 30 =
Plate Offsets (X 1)-
12:0-1-4 Edgel,l6.0-1-4 Edgel
LOADING (ps0
SPACING- 2-0-0
CSI.
DEFL
in
(lee)
Vdefl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.39
Vert(LL)
0.09
8-10
>999
360
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.58
Ved(TL)
-0.22
8-10
>999
240
BCLL 0.0 '
Rep Stress Incr NO
W B 0.21
Horz(TL)
0.05
6
rVa
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Mabix-M)
Weight: 971b FT=20%
LUMBER- BRACING•
TOP CHORD 2x4 SP No.2 TOP CHORD
Structural wood sheathing directly applied or 4-0-14 oc purlins.
• BOT CHORD 2x6 SP No.2 BOT CHORD
Rigid ceiling directly applied or 6-8-15 oc bracing.
WEBS 2x4 SP No.3
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
• REACTIONS. (lb/size) 2=103510-8-0 (min. 0-1-8), 6=1035/0-8-0 (min. 0-1-8)
Max Horz2=72(LC 26)
Max UpIifY2= 619(LC 8). 6= 640(LC 9)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-15=-1794/992, 2-3=-1881/1064, 3-1 6=-1664/1009,4-1 6=-1664/1009, 4-17=-1664/1050,
5-17= 1664/1050, 5-6= 1881/1110, 6-18= 1794/980
BOT CHORD 2-19=-885/1623, 2-10--897/1635, 10-20— 1206/1995. 9-20= 1206/1995, 9-21= 120611995,
8-21=-1206/1995,6-8--872/1635, 6-22--860/1623
WEBS 3-1 0=-1 56/530, 4-10=-421/436, 4-8=-450/474, 5-8= 167/530
NOTES- (10)
1) Unbalanced mot live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd-132mph; TCDL=4.2psf; BCDL-3.Opsh h=151t; Cat. 11; Exp C; Encl., GCpiv0.18;
MW FRS (envelope); Lumber DOL-1.60 plate grip DOL-1.60
3) Provide adequate drainage to prevent water pending.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ito uplift at joint(s) except Qt=lb) 2=619.
6=640.
7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 175 lb down and 246lb up at 5-0-0,
91 lb down and 112 lb up at 7-0-12, 91 lb down and 112 to up at 9-0-12. 91 lb down and 112 lb up at 9-5-4, and 91 Ib down and 112 lb
up at 11-5-4, and 195 Ib down and 242 Ib up at 13-6-0 on top chord, and 83 lb down and 22 lb up at 5-0-0, 35 Ib down and 8 lb up at uss tses,%
7-0-12, 35lb down and 8 lb up at 9-0-12, 35 Ito down and 8 to up at 9-5-4, and 35 lb down and 8 lb up at 11-5-4, and 83 go down and 0l W, GY�4
lb up at 13-5-4 on bottom chard. The design/selection of such connection device(s) Is the responsibility of others. �� O
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).�,10ENgF,•C�
10) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." Z
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase-1.25, Plate Increase=1.25
Uniform Loads (pit)
Vert:1-2=-54, 2-15= 14, 3-15=-S4, 3-5=-54, 5-18=-54, 6-18=-14, 6-7=-54, 2-6=-20
Continued on page 2
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559
* : d_L4
STATE OF
P.
08/25/2016
Job russ
toss ype y
848709-SWrgell Res.
848709 T32
Hip Giber 1 1
8487090"
Job Reference (optional)
tlelleeR Feersource, Flan[ city, M: bbb
sums r.o m s aan ee co 1. nun: i.o ice. man— ... o -I--n���o--.
ID:o83Fw hkmDOkA20AOiCOM?yu7C&pylg4GtocRdpSbaNXOFOXN2g6if NVPCfu6i6Lyu5C7
LOAD CASE(S) Standard
Concentrated Loads (Ib)
Vert: 3=-103(F) 5=-103(F) 9=-47(F) 10=-47(F) 4=-91(F) 8=-47(F) 16= 46(F) 17=-46(F) 20=-24(F) 21=-24(F)
0
STATE OF - _
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016
Uoli -- Tss
I russ I ype Gtyy y
"8709-Sturgell Res.
M8709 T33
Hip Girder 1 1
f149709005
Job Reference (optional)
Builders Firsl5ource, Plant City, FL 33560
5x6 =
-2xl 11
10 3 11
12
5x6 =
Scale =131.2
Plate Offsets (X,Y)—
0:0-2-O.Edgel [2:0-3-0 0-2-0] [4:0-3-0
0-2-01 [5:0-2-0 Edgel
[7:0-4-0,02-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL
in
(too)
Well
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.51
Vert(LL)
0.11
7
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.51
Vert(TL)
-0.17
6-7
>999
240
BCLL 0.0 '
Rep Stress Incr NO
WB 0.23
Hom(TL)
0.06
5
n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix)
Weight: 84 lb FT=20%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 1=97310-8-0 (min. 0-1-8),5=973/0-8-0 (min.0-1-8)
Max Hom 1=57(LC 7)
Max Upliftl=-566(LC 8), 5=-566(LC 9)
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-10-4 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-1-7 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1784/1045, 2-9=-2001/1282, 9-10=-2001/1281, 3-10=2001/1281, 3-11— 2001/1281,
11-12=-2001/1281, 4-12= 2001/1282, 4-5=-1784/1045
BOT CHORD 1-8=-915/1514, 8-13= 916/1504, 13-14=-916/1504, 7-14=-916/1504, 7-15= 873/1504,
15-16=873/1504, 6-16= 873/1504, 5-6=-871/1514
WEBS 2-8=0/287, 2-7=-414/610, 3-7=-407/431, 4-7=414/610, 4-6=0/287
NOTES- (10)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MW FRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except T=lb) 1=566,
5=566.
7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 175 Ill down and 246 Ito up at 5-0-0,
91 lb down and 112 Ib up at 7-0-12, 91 lb down and 112 Ib up at 9-0-12, 91 Ib down and 112 lb up at 10-1-4, and 91 lb down and 112 Ib
up at 12-1-4, and 1751b down and 246lb up at 14-2-0 on top chord, and 83 Ill down and 22 Ib up at 5-0-0, 35 Ito down and 8 Ito up at fmna+p
7-0-12, 35 lb down and 8 Ib up at 9-0-12, 35 lb down and 8 goup at 10-1-4. and 35 It,down and 8 Ib up at 12-1-4, and 83 lb down anidOESiT W, N'
221b up at 14-1-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. Q O ......
I • '4���4
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). �; V� sF'• S
10) "This manufactured product is designed as an individual building component. The suitability and use of this component for any C
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." 2
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 ,d :•• STATE OF
Loads
UniformVert: 1 2PI 54, 2-4=.54, 4-5=-54, 1-5=-20 �990 • . OR700; �r4�
E
Continued on page 2 0� ",u �TNG
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016
Job Truss film, ype lY y 848709-Sturgell Res.
848709 T33 Hip or 1 1 M8709045
Job Reference (optional)
Builders FimtSou¢e, Plant City, FL 33566 Run: 7.610 a Jan 29 2015 Print: 7.610 s Jan 29 2015 MTek Industries, Inc. Tue Jul 2621:91:43 2016 Page 2
ID:aB3FwmhkmDOkA20AOiCOM?yu7CBd9s3lcuONllg419a4imd4abg4mGy6?ELuYyRwoyu5CE
LOAD CASE(S) Standard
Concentrated Loads (Ib)
Vert: 4=-103(F) 8=-47(F) 2= 103(F) 6=-47(F) 9=-46(F) 1 0=-46(F) 11_ 46(F) 12=-46(F) 13= 24(F) 14= 24(F)15= 24(F) 16=24(F)
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, Fl 33559 08/25/2016
Roof Special Ctr or 1'
Run: 7.610s Jan 292015 Pm
I0:oB3FwmhkmDOkA20
12-3-0 13-9-0 19-8-3
5&4 1-6-0 5-11-3
7x10
6.00 F12
6
8xlo = axe =
6-6-12 123-0 18-,-14 25-fi-0
6812 bed 18.1-14 5 6-
Scale=1.48.5
Plate Offsets (X Y)—
f2:0-1-11 Edgel, f4:0-3-0 Edgel f6:0-2-12
0.4-121
f8:0-1-11.Edgel
f9:0-4-4 0-4-121 f10:0-3-12 0-4-81
f11:0-4-8 0-0-01
LOADING (psi)
SPACING. 2-0-0
CSI.
DEFL
in (too)
Vdefl
Ud
PLATES GRIP
TOLL 20.0
Plate Grip DOL 1.25
TO
0.53
Vert(LL)
0.32 11-12
>945
360
MT20 244/190
TOOL 7.0
Lumber DOL 1.25
BC
0.91
Ved(TL)
-0.52 9-10
>576
240
BOLL 0.0 '
Rep Stress [nor NO
WB
0.99
Horz(TL)
0.14 8
n/a
n/a
BCDL 10.0
Code FBC20141-rP12007
(Matrix)
Weight: 3141b FT=20%
LUMBER -
TOP CHORD 2x4 SP M 31
BOT CHORD 2x6 SP M 26-ExcepV
B2:2x4 SP No.1
WEBS 2x4 SP No.3 *Except*
W3,W5:2x4 SP No.2
REACTIONS. (lb/size) 8=7507/0-8-0 (min. 0-4-7), 2=536810-8-0 (min. 0-3-3)
Max Horz2=208(LC 27)
Max Uplih8=-3861(LC 9), 2=3030(LC 8)
BRACING -
TOP CHORD Structural wood sheathing directly applied or 4-4-1 oc puffins.
BOT CHORD Rigid ceiling directly applied or 8-11-9 oc bracing.
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=-11232/6314, 3-4=-9685/5285, 4-5=-9611/5296, 5-6=9654/5409, 6-7=-11815/6232,
7-8=-1194316221
BOT CHORD 2-12=-5672/9890, 12-13=-770/1285, 13-14= 770/1285, 14-15=-770/1285, 11-15=-770/1285,
10-11=-895/1590, 10-16=-382077248,16-17= 382077248,17-18=-3820/7248,
9-18= 3820/7248,9-19=-5449/10579,19-20=-5449/10579,20-21= 5449/10579,
21-22=-5449/10579, 8-22=-5449/10579
WEBS 3-12— 816/1135,10-12=-4981/8744,3-10=-1442/1115,6-10=-3108/5194, 6-9=-2725/5396,
7-9=-296/376
NOTES (10)
1) 2-ply truss to be connected together with 1 Od (0.131 "4") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-6-0 oc, 2x4 -1 row at 0-9-0 oc.
Webs connected as follows: 2x4 -1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASES) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 00tlttttt8%'rr
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. rs Ri W 6p
6)*This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide wiydit5b � �,C
between the bottom chord and any other members. Q' ,•`,\OENSF
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (ji=1b)
2=3030. ;
8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1892 lb down and 1281 lb up &*
7-1-9, 1005 It, down and 593 lb up at 9-0-12,1005 Ib down and 601 lb up at 11-0-12, 1005 fib down and 598 lb up at 13-0-12. 10 I STATE OF
down and 491 lb up at 15-0-12, 1015 lb down and 505lb up at 17-0-12, 1015 lb down and 511 lb up at 19-0-12, 999 lb down and I ,b". ••
up at 21-0-12, and 999 lb down and 509 lb up at 23-0-12, and 999 lb down and 509 lb up at 24-6-12 on bottom chord. The y40PIOP� �aW
design/selection of such connection device(s) is the responsibility of others. �i�SSfG�q` ENG��
Continued on page 2tthmm„�
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559 08/25/2016
Job Trusts
wss type ty y
M709-Sturgell Res.
U8709 T34
Root special Girder 1 n
2848Job
Reference tional
Builders DrstSource, Plant City, R. 33566 Run: 7.610 s Jan 29 2015 Print: 7.610 s Jan 29 2015 Mirek Industries, Inc. Tue JUI26 21 01M 2016 Page 2
ID:oB3FwmhkmDOkA20AOiCOM?yu7CB-mLPRVyv273tXhvkmeOHsca8_O9FyrGfV7Ci_SEqu5C5
10) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the
building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
1) Dead +Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
- Uniform Loads Of)
Vert: 1-6= 54, 6-8=54, 2-11=-20, 8.10— 20
Concentrated Loads (lb)
-- -- - Vert: 13= 1892(B)-14==1005(9)-15=7005(B)16= 1005(B)17= 1008(B)18==1015(B)-19=-1015(B) 20=-999(e)21==999(8)22a-999(B)-
%v,
S7/l7E OF .1
y�O�c n ;;OR70P;\a0
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016
doo rruss
I was I ype Uly Hly
848709-Sturgell Res.
848709 T35
Roof Special 9 1
848709047
Job Reference c tional
bulders Fhal50uree, Plant City, FL 33566 Run: 7.610 s Jan 292015 Pdrn: 7.610 a Jan 29 2015 Walk Induatdea, Inc. Iue Jul 26 21:0194 2016 Page 1
ID:oB3FwmhkmDOkA20AOiCOM?yu7CB-mLPRVyv2731XhvkmeOHsco8xo91ZrJPV7Ci_SEqu5C5
-14-0 6.2-12 12-3-0 13-9-0 19-7-7 25-6-0 26-10-0
r1-0-0 52-12 6-0-5 180 5-10-7 5-10-9 1-4-01
4x6 =
6.00 12
4x6 = 2x4 11
6-2-12 12-3-0 16-tL 13 l 256-0 6-2-12 6-0-5 6-5-13 6-9-3
Scale =1:49.3
Plate Offsets (X,Y)--
I2:0-1-8 Edgel I4:0-3-0 Edcel
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL
in (loc)
Well
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.77
Ved(LL)
0.1210-11
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.55
Vert(TL)
-0.2610-11
>999
240
BCLL 0.0 '
Rep Stress Incr YES
WE 0.81
Horz(TL)
0.07 8
n/a
n/a
BCDL 10.0
Code FBC2014/fP12007
(Matrix)
Weight: 139 lb FT=20%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP N0.2 *Except*
B2: 2x4 SP No.3
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=101210-8-0 (min. 0-1-8), 8=1012/0-8.0 (min. 0-1-8)
Max Horz2=190(LC 12)
Max Uplift2— 503(LC 12), 8= 4a3(LC 13)
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-9-3 oc pudins.
BOT CHORD Rigid ceiling directly applied or 5-2-2 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3= 1948/1552, 3-4=-1652/1363, 4-5=-159011374, 5-6=-1657/1541, 6-7=-193211688,
7-8=-1984/1574
BOT CHORD 2-13= 1234/1657, 5-11=-266/378, 11-14=-639/1123, 14-15=-639/1123, 10-15=-639/1123,
8-10=-1206/1685
WEBS 11 -1 3=-1 207/1640, 3-11=-348/456, 6-11= 724/839, 6-10= 629/701, 7-10=-366/538
NOTES- (7)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; VulI=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL= 10.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joints) except Qt=lb) 2=503,
8=483.
6) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
STATE OF "-
g��.tk�FyOR10P� a��•'
�.r-\ J•
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, PI 33559 08/25/2016
Job Iruss
rues I ype Uty My
848709-Sturgell Res.
M8709 T36
Common 3 1
B48709NB
Job Reference o tional
BuJ4ers RrstSource, Plant City, FL W566
2x4 II
6.00 12
5x6 =
ix4 — 3x8 =
Scale=145.4
3x4 = ass II
6-2-12 13-941 21-3-4 25-54
G2-12 I 7-64 I 7-64 4-2-0
Plate Offsets (X Y)--
12:0-1-8 Edgel 14:0-3-0 Edge] 17:0-2-12
0-2-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL
in (too)
Vdefl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.96
Vert(LL)
0.10 11-13
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.63
Vert(TL)
-0.2111-13
>999
240
BCLL 0.0 '
Rep Stress ]nor YES
WB 0.95
Horz(TL)
0.05 9
n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix)
Weight: 134 lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD
SOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3 BOT CHORD
REACTIONS. (lb/size) 2=1017/0-8-0 (min. 0-1-8), 9=1010/0-7-4 (min. 0-1-8)
Max Horz2=192(LC 12)
Max Uplift2= 505(LC 12), 9= 481(LC 13)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3= 1929/1596, 3-4=-1253/1110, 4-5=-1174/1128, 5-6= 1250/1125, 6-7= 1425/1221,
7-9=-115111139
BOT CHORD 2-13=1286/1653, 12-13= 1286/1653, 11-12=-1286/1653, 10-11=-973/1255
WEBS 3-13=0/280,3-11=-7571799,5-11=-427/573,6-11=-312/429, 6-10= 238/340,
7-10=-1068/1298
Structural wood sheathing directly applied or 2-2-0 oc pudins, except
end verticals.
Rigid ceiling directly applied or 5-2-3 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES (7)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vu1t=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Extenor(2) zone;C-C for members and fames & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except (jt=1b) 2=505,
9=481.
6) "Semi -rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.' -
LOAD CASE(S) Standard +`-Q" • ENE '9 �1
S*r
STATE OF
wk
'sass/pNAI
mhsaaMaq
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016
Job russ
rusS lype y
M8709 - Stanger Res.
U8709 T37
Hip 1 1
M6709049
Job Reference (optional)
Builders FntSource, Plant City, R. 33566 Run: 7.610 a Jan 29 2015 PnnV 7.610 s Jan 292015 MTex Industries, Inc. Tue Jul 26 21L1 A5 2016 Page 1
ID:oB3FwmhkmDOkA20AOiCOM?yu7CB-EXzpiHwguM?OJ2JyC8p59?g4yZgcak5eMsRXyyu5C4
l" o
-t-4-0 s-2-ttP 13-UO 13-s-o zt-3.4 zssr zsiao_
1-0-0 6-2-11 6-9-5 4-2-1 - r 1-0 12 '
Scale =1 A5.9
3x6 = 3x6 II
fi.W 12 3x6=
5 6 7
_... 2x4 It 3x4 = 3x6 = 3x4 = 3x6 11
6-2-11 13-9-0 1 213-4 1 25-5-4
6-2-11 7-6-5 783 4-A
Plate Offsets (KY--
f2:0-1-8 Edge], t4:0-3-0 Ed el 15:0-3-8
0-2-41 [7:0-3-8 0-2-41
19:0-3-0 0-1-121
LOADING (psi)
SPACING- 2-0-0
CSI.
DEFL
in (too)
Vdefl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.87
Vert(LL)
0.09 13-15
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.62
Vert(fL)
-0.2213-15
>999
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.91
Horz(TL)
0.05 11
n/a
We
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
Weight: 133 lb FT = 20
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
BOTCHORD
REACTIONS. (lb/size) 2=1017/0-8-0 (min. 0-1-8), 11-1010/0-7-4 (min. 0-1-8)
Max Horz2=185(LC 12)
Max UplifP2=-499(LC 12), 11=-474(LC 13)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1912/1574, 3-4=-1255/1114, 4-5=-11 a3/l l28, 5-6=-1093/1135, 6-7= 1093/1135,
7-8=-125211125,8-9=-1409/1200, 9-11=1147/1134
BOT CHORD 2-15=-126211635, 14-15=126211635, 13-14=126?J1635, 12-13— 945/1234
WEBS 3-15=0/281, 6-13= 392/546, 8-12=-226/325, 9-12=-1017/1258, 3-13=-725/757,
8-13=-277/383
Structural wood sheathing directly applied or 3-10-11 oc purlins,
except end verticals.
Rigid ceiling directly applied or 5-2-6 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES (8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=499,
11=474.
7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particulary� �rzry4�i�
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.' eaO$Ei'•S
LOAD CASE(S) Standard C' ¢•� .\1\0ENSf •.�{
STATE OF
��FiyNIONAL ENG�.+`a'
oinut"So
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, Fl 33559 08/25/2016
JoD Truss
Was I ype LAY
M8709-SNrgell Res.
848709 T38
1MY
Hip 1 1
648709050
Job Reference c tional
aWldele PIrcc'ourCa, Plant Glty, FL 33566 Run: 7.610 s Jan 29 2015 Pnnt 7.610 s Jan 29 2015 Wek Industries, Inc. Tue Jul 2621:01.46 2016 Pagge 1
ID:oB3Fwmhkm OOkA20AOICOM?yu7CB-ikXBwdwlfg7FxCugmrKKhDDGvz1 pJFdoaWB5X7yu5C3
I_1-0-0 3-9-60 I 24 25-64 26-10-0
66.-22122 14-0I 29-0 169-0 4-94 42-0 1-
3x6 =
2x4 II 3x6 =
Scale =1:452
2x4 II 4x4 = 3x8 = 3x4 = 3x6 11
6-2-12 13-9 0 21-34 25.54
6-2.12 I 7-6-4 I 7.6-4 42-0
Plate Offsets (X,Y)--
f4:0-3-0,Ednel 16:0-3-0 Edgel
LOADING (psi)
SPACING- 2-0-0
CS].
DEFI-
in (loc)
I/deb
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TIC 0.79
Vert(-L)
0.21 12
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.56
Vert(TL)
-0.4012-14
>745
240
BCLL 0.0 '
Rep Stress Incr YES
W B 0.70
HOR( I-)
0.05 10
n/a
n/a
BCDL 10.0
Code FBC2014/rP12007
(Matrix)
Weight: 131 lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP N0.2 -Except'
TOP CHORD
- T2: 2x4 SP No.1
BOT CHORD 2x4 SP No.2
BOT CHORD
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=1017/0-8-0 (min. 0-1-8), 10=1010/0-7-4 (min. 0-1-8)
Max 1-1o¢2=164(LC 12)
Max Uplift2= 483(LC 12), 1 0= 455(LC 13)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 fib) or less except when shown.
TOP CHORD 2-3=-1854/1505, 34=-1294/1162, 4-5— 1155/1139, 5-6=1155/1139, 6-7= 1290/1157,
7-8=-1356/1137, 8-10= 1141/1123
BOT CHORD 2-14_ 1182/1566, 13-14=-1182/1566, 12-13=-1182/1566,11-12=-858/1159
WEBS 3-14=0/295, 3-12=-559/571,5-12= 232/453, 7-11= 177/274, 8-11=-860/1119
Structural wood sheathing directly applied or 3-7-0 oc purlins, except
end verticals.
Rigid ceiling directly applied or 5-1-6 oc bracing.
MITek recommends that Stabilizers and required crass bracing
be installed during truss erection, in accordance with Stabilizer
Installation '.ids
NOTES- (8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water pounding.
4) This truss has been designed for a 10.0 fast bottom chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=1b) 2=483,
10=455.
7)'Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) -This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.' ,� x'•81%QT �',� ��
Nq: X}GENgF ..eel
LOAD CASE(S) Standard
..qq,, STATE OF,,Q�..
j0iPF.. *tOR%Ot:.�\��R�
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016
Job Truss
teas I ype
Ply
M709-SNrgell Res.
848709 T39
Hip
JVY
1 1
848709051
Job Reference (optional)
uumels ri su ource, Flan uty, rL:i W
46 =
3x4 —
46 =
M = "` — 5x8 = 3x6 II
9-00 18-6-0 25-5-4
9-0-0 9-6-0 &114
Scale =1.452
Plate Offsets (X Y)--
I7:0-1-0 0.2.01
LOADING (Pat)
SPACING- 2-0-0
CSI.
DEFL
in
(too)
Vdefl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.91
Vert(LL)
-0.13
2-12
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.83
Vert(Q
-0.36
2-12
>834
240
BCLL 0.0
Rep Stress lncr YES
WB 0.46
Horc(TL)
0.05
9
n1a
n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix)
Weight: 1321b FT=20%
LUMBER-
BRACING -
TOP CHORD
2x4 SP No.2
TOP CHORD
- BOT CHORD
2x4 SP No.2
WEBS
2x4 SP No.3 *Except*
BOT CHORD
W5: 2x6 SP No.2
REACTIONS. (lb/size) 2=1014/0-8-0 (min. 0-1-8), 9=1011/0-7-4 (min.0-1-8)
Max Hom2=144(LC 12)
Max Uplitt2=-461(LC 12), 9=431(LC 13)
FORCES. fib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3— 1768/1455, 3-4=-1592/1405, 4-5=-1395/1268, 5-6= 1223/1141, 6-7=-1398/1141,
7-9=-1099/1126
BOT CHORD 2-12=-1137/1501, 11-12=1023/1401, 10-11=-1023/1401, 9-10=-301/299
WEBS 3-12=-357/485, 4-12=-488/582, 5-10=-369/357, 6-10=-104/317, 7-10=-512/876
Structural wood sheathing directly applied or 2-2-0 oc purlins, except
end verticals.
Rigid ceiling directly applied or 5-2-13 oc bracing.
Mi fek recommends that Stabilizers and required cross bracing
be installed during Wss erection, in accordance with Stabilizer
Installation guide.
NOTES- (8)
1) Unbalanced root live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ik Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of 20.Opst on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) except Qt=1b) 2=461,
9=431.
7) "Semi-dgid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8)'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
a` SINT W. yq.,.
�44., STATE Of �i�
4yO,t.�ti�0A1OA' 0q'.•
LOAD CASE(S) Standard
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, Fl 33559
08/25/2016
Job
N65
I Ns3 i ypeLAY My
848709-SNmell Res.
848709
T40
Hip Gialer 1 1
848709052
Job Reference (optional
Builders FirstSource, Plant City, FL 33566
Scale =1:452
- - -5x6= - - -2K41I 5x6 =- -
2x4 II am = 5x8 =
5x8 =
Plate Offsets (X Y)--
f3:0-4-0 0-2-81 f5:0-3-0 0-2-01 (9:0-3-8
0-2-81
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL
in (too)
I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.92
Vert(LL)
0.2010-12
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.78
Vert(tL)
-0.36 10-12
>819
240
BCLL 0.0
Rep Stress Incr NO
WB 0.98
HorzjQ
0.09 8
n1a
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
Weight: 128 lb FT = 20
LUMBER -
TOP CHORD 2x4 SP No.1 'Except'
T2: 2x4 SP M 31
BOT CHORD 2x4 SP No.1
WEBS 2x4 SP No.3 *Except*
W2: 2x4 SP No.2, W5:2x6 SP No.2
BRACING -
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOT CHORD Rigid ceiling directly applied or 4-9-4 oc bracing.
MITek recommends [hat Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation uide.
REACTIONS. (lb/size) 2=1683/0-8-0 (min. 0-2-0), 8=1870/0-7-4 (min. 0-23)
Max Horz2=124(LC 8)
Max Uplift2— 1066(LC 8), 8=1147(LC 9)
FORCES. (Ib) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3= 3005/1882, 3-13=-3267/2166, 13-14=-3267/2165, 14-15= 3267/2165, 4-15= 3267/2165,
4-16= 3267/2165, 16-17= 3267/2165, 17-18=-3267/2165, 5-18=-3267/2166, 5-19=-2224/1450,
19-20=-2273/1434,6-20=-2347/1453, 6-8=-176711101
BOT CHORD 2-12=-1642(2578, 12-21=-1639/2562, 21-22=-1639/2562, 11-22=-1639/2562,
11-23=-1639/2562,10-23=-1639/2562,10-24= 1242/2036, 24-25= 1242/2036,
25-26=-1242/2036, 9-26= 1242/2036
WEBS 3-12=-74/564, 3-10= 637/896, 4-10= 755l797, 5-10= 953/1407, 6-9= 1225/1959
NOTES (10)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MW FRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except (jt=11b) 2=1066,
8=1147.
7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Hanger(s) or other connection devices) shall be provided sufficient to support concentrated load(s) 233 lb down and 3261b up at 7-0-Q1
1081b down and 158 Ib up at 9-0-12, 108 It, down and 158 It, up at 11-0-12, 108 Ib down and 158 Ib up at 13-0-12, 108 lb down an
158lb up at 15-0-12, 108 lbdown and 1581b up at 17-0-12, 108 Ib down and 158 Ib up at 19-0-12,108 Ib down and 158 Ib up at Q
20-6-0, and 84lb down and 321b up at 21-5-4, and 89 Ib down and 971b up at 23-5-4 on top chord, and 205 lbdown and 134 lb L4 at
7-0-0, 65 Ib dawn and 3 lb up at 9-0-12, 65 Ib down and 3 Ib up at 11-0-12, 65 Ib down and 3 Ib up at 13-0-12, 651b down and 3 up pl
15-0-12, 65 lb down and 3 Ito up at 17-0-12, 65 It, down and 3 Ib up at 19-0-12, 65 Ito down and 3 Ito up at 20-5-4, and 149 Ib dowEqnd
161 to up at 21-5-4, and 76 lb down and 51 Ito up at 23-5-4 on bottom chord. The design/selection of such connection device(s) p t#fe
responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).5�f
10) "This manufactured product is designed as an individual building component. The suitability and use of this component for any ya1�
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."h
TnAVLOAS®($)aIffadard
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559
dij I
STATE OF , _
08/25/2016
Job I rus5
fuss I yps Ply
M709-Stumell ReS.
W709 T40
Hip Gird., 1 1
848709052
Job Reference (optional)
builders FlrslSource, Plant City, FL 33566
Run:7.610 a Jan 292015 YfiOC 7.610 SJan29 ZUlb M l e81nOusPles, InC, Iue Jul 2ti 21U1:9/Zulu Yag.,
ID.oB3FwmhkmDOkA20AOiCOM7yu7CB-Aw5Z7zxiv0_F5ZMTLJZrZEOmPfNJf2dYxpAwe3Zyu5C2
LOAD CASE(S) Standard
1) Dead+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pig
Van: 1-3=-54, 3-5=-54, 5-6=-54, 6-7=-54, 2-8=-20
Concentrated Loads (lb)
Vert: 5=-87(F) 12= 202(F) 3= 171(F) 9=-40(F) 13=-87(F)14_ 87(F) 15= 87(F) 16=-87(F) 17=-87(F) 18=87(F) 19=5(F) 20=-49(F) 21=-40(F) 22_ 40(17 23= 40(F)
24= 40(F) 25=-40(F) 26=-40(F) 27-149(F) 28=-76(F)
It
n p STATE OF 2,�
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/20 1 6
Job inuss
I rum I ype y
848709-Stagell Res.
U8709 Vol
Valley 2 1
M8709053
Job Reference o tional
Builders FistScurce, Plant City, FL 33566
2x4 i
3x4 =
2
2x4
Scale =1:7.5
a
0
LOADING (psf) SPACING- 2-0-0
TCLL 20.0 Plate Grip DOL 1.25
TCDL 7.0 Lumber DOL 1.25
BCLL 0.0 ' Rep Stress Incr YES
BCDL 10.0 Code FBC2014/TPI2007
CSI.
TC 0.08
BC 0.15
WE 0.00
(Matrix)
DER. in
Vert(LL) r9a
Vert(TL) n/a
Horz(TL) -0.00
(loc) I/defl L/d
- n/a 999
- n/a 999
3 n/a We
PLATES GRIP
MT20 2441190
Weight: 101b FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 4-0-0 oc purlins.
- SOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommend that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation uide.
REACTIONS. (lb/size) 1=101/3-11-0 (min. 0-1-8),3=101/3-11-0 (min.0-1-8)
- Max Horz 1=15(LC 9)
Max Upliftl=-48(LC 12), 3=-48(LC 13)
FORCES. (Ib) - Max. Comp./Max. Ten. -All forces 250 gb)
or less except when shown.
NOTES- (8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) 1, 3.
7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
���o �pT W, jyq•,.
STATE OF
1-Ne
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016
Joe lrusus
I was I ype
ty Ply
M8709-SWrgell Res.
M8709 V02
Valley
2 1
848709054
Job Reference (optional)
Builders FustScurce, Plant City, FL W566
3a4 G
mil
Run: 7.610 s Jan 292015 Pnnt 7.610 s Jan 29 2015 Unrek IndusMes. Inc. Tue Jul 26 21:01 AB 2016 Page 1
ID:oB3FwmhkmDOkA20AOiCOM?yu7CB efifyWyYBHNyAW2XlGMonelmmnnpnlr52ggBb?yu5C1
4xa =
3x4 a
Scale-1:14.3
u-u-8
7-11.8
LOADING (psQ
SPACING- 2-0-0
CS1.
DEFL in
(too) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.19
Vert(LL) We
- n/a 999
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.27
VerhTL) n/a
- n/a 999
BCLL 0.0 '
Rep Stress ]nor YES
WB 0.08
Holz(TL) 0.00
3 n/a n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
Weight: 25 to FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (It/size) 1=111/7-11-0 (min. 0-1-8), 3-111/7-11-0 (min. 0-1-8), 4=27617-11-0 (min. 0-1-8)
Max Horz1= 38(LC 8)
Max Upliftl=-64(LC 12), 3= 71(LC 13), 4= 107(LC 12)
Max Grav 1=114(LC 25). 3=114(LC 26), 4=276(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 2-4--218/270
NOTES (8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=l32mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. IC Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Extedor(2) zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chard and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3 except Ot=lb)
4=107.
7) "Semi-dgid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
8)'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code'
LOAD CASE(S) Standard
$IV p`o....... ..4 --
If : P4,0Ct t71
STATE OF
y10A
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016
Scale=1:18.6
a
0
0
3x6 G 2r4 II 3x611
tl-tlb
11-11-8
'
LOADING (psQ
SPACING- 2-0-0
CSI.
DEFL
in (too)
VdeO
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.45
Vert(LL)
n/a -
n/a
999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.66
Vert(TL)
n/a -
n/a
999
BCLL 0.0 '
Rep Stress [nor YES
WB 0.11
Horz(TL)
0.00 3
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
Weight: 39 lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pur ins.
BOT CHORD 2x4 SP No.3
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
Mi fek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (lb/size) 1=177111-11-0 (min. 0-1-8), 3=177/11-11-0 (min. 0-1-8), 4=439/11-11-0 (min.0-1-8)
Max Horz 1=-60(LC 8)
Max Upliftl=102(LC 12), 3=-113(LC 13), 4=-170(LC 12)
Max Gravl=180(LC 25), 3=180(LC 26), 4=439(LC 1)
FORCES. (Ib) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 2-4=-332/379
NOTES- (8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) except (jt=11b) 1=102,
3=113, 4=170.
7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8)'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
* : �•'1S't WV
STATE OF T
A,
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559 08/25/2016
Joe Truss
Inuss type
Fly
848709-SWrgHIRes.
848709 VOA
Valley
1 1
848709056
Job Reference o tional
Builders Fi 5 ouree, Plant City, K N556 Run: 7.610 a Jan 292015 Print: 7.610 a Jan 29 2015 Knelt InduSTIe5, Inc. Tue Jul 2621 V 1:49 201b Page 1
ID:oB3FwmhkmDOkA20AOICOM?yu7CB-6JDKYfzBybVpogcjR_tl JrmrA5i Wk?EGUP17Ryu5CO
6-1-2 8-0-0 9-10-14 16-0-0
6-1-2 1-10-14 1-10-14 6-1-2
Scale =124.9
7 fi
3x4' 2x4 11 2x4 11 3x4
0-g$ 6A-2 9-10-14 16-0-0
0- $ 6-0-10 3-9-12 I 6-1-2
Plate Offsets (X Y)--
(3:0-2-0 Edgel
LOADING (psQ
SPACING- 2-0-0
CSL
DEFL
in (loc)
Udell
Ud
PLATES GRIP
TOLL 20.0
Plate Grip DOL 1.25
TO 0.36
Vert(LL)
n/a -
n/a
999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.36
Vert(TL)
n/a -
n1a
999
BCLL 0.0 '
Rep Stress Incr YES
WB 0.15
Hoa(fL)
0.01 5
n1a
n/a
BCDL 10.0
Code FBC20141TP12007
(Matrix)
Weight: 55 lb FT=20%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2z4 SP No.3
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. All bearings 15-11-0.
(Ih) - Max Horz 1=-82(LC 8)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 7=-289(LC 12), 6=-286(LC 13)
Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=401(LC 25), 6=401(LC 26)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-253/153, 4-5=-253/153
BOT CHORD 1-7= 134/334, 6-7=134/334, 5-6=134/334
WEBS 2-7= 378/506, 4-6= 378/506
NOTES- (8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; VuIt=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ih uplift at joint(s) 1, 5 except (jt=lb)
7=289, 6=286.
7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
6)-this manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
W.
STATE OF
q : Q�
�q,O,t•••fLOR10A� �txrt"p`
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016
Job Truss
I rus9 I ype
UlY y
848709-Stumell Res.
848709 V05
Valley
1 1
848709057
Job Reference (optional)
Builders FIrslSou oe, Plant Gty, FL 33566 Run: 7.6105 Jan 29 2015 PdnC 7.610 s Jan 29 2015 M Iall Industries, Inc. Tue Jul 26 21:01:49 2016 Page 1
ID:oB3FwmhkmDOkA20AOICOM?yu7CB-6JDKYfzeybVpogcjR_UJrrtOA6mW WEGUP17Ryu5C0
5-1-2 10-0-0 14-10-14 20-0-0
' 5
-1-2 410-14 i 4-10-14 5-1-2 l
Scale =1 a1.1
a
0
0
3x4 O 8 7 6 3x4 0
2x4 II 5x6 = 2x4 II
Plate Offsets (X,Y)--
(7:0-3-0,0-3-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL
in (lac)
Vdefl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.39
Vert(LL)
n/a -
n/a
999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.29
Vert(TL)
n/a -
n/a
999
BCLL 0.0 '
Rep Stress Incr YES
WB 0.16
Horz(TL)
0.00 5
n/a
n/a
BCDL 10.0
Code FBC2014/rP12007
(Matrix)
Weight: 73 lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD 2x4 SP No.3 BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
MiTek recommends that Stabilizers and required cross bracing
OTHERS 2x4 SP No.3
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. All bearings 19-11-0.
(lb) - Max Hom 1=-104(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 7 except 8=-313(LC 12), 6=-313(LC 13)
Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=317(LC 1), 8=411(LC 25), 6=411(LC 26)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
WEBS 2-8=-391/540, 4-6=-391/540
NOTES- (8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult-170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. Il; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Gable requires continuous bottom chord hearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chard in all areas where a rectangle 3-6-0 tall by 2.0.0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)1, 5, 7 except (jt=lb)
8=313, 6=313.
7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.'
LOAD CASE(S) Standard
w,
y STATE OF e,•Q
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559 08/25/2016
Job russ
Iruss I ype LIty Ply
848709-Stu,, Res.
M8709 vos
Valley 1 1
8487ON58
Job Reference (optional)
Builders F1rstSource, Plant City, FL 33566
Scale =1:18.9
3x4 =
9c4 II 3x4 =
J 3 4
6
3K4 i 2K4 11 3K4 O
Plate Offsets X(,_Y)—[2:0-2-0,0-2-81.
14:0-2-0,0-2-81
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL
in (too)
Well
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.33
Vert(LL)
n/a -
n/a
999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.46
Vert(TL)
n/a -
n/a
999
BCLL 0.0 '
Rep Stress Incr YES
WB 0.05
Horz(TL)
0.01 5
n/a
We
BCDL 10.0
Code FBC2014/rPI2007
(Matrix)
Weight: 38 lb FT-20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 cc purlins.
BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 9-4-6 cc bracing.
OTHERS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (lb/size) 1=261/11-11-0 (min. 0-1-8), 5=261111-11-0 (min.0-1-8), 6=274/11-11-0 (min.0-1-8)
Max Horz 1-44(LC 11)
Max Uphill=-152(LC 12), 5=-155(LC 13), 6=-77(LC 9)
Max Grav 1=261(LC 1), 5=261(LC 1). 6=275(LC 3)
FORCES. (lb) - Max. CompJMax. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 1-2=-388/461, 2-3=-337/496, 3-4=-337/496, 4-5=-388/461
BOT CHORD 1-6=300/285, 5-6=-300/285
NOTES- (9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL-3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MW FRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of thus to bearing plate capable of withstanding 100 lb uplift at joint(s) 6 except aWb) 1=152,
5=155.
8) "Semi -rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
Jr 0 PT W. 6yti4�
.q STATE OF
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559 08/25/20 1 6
Job Was
was yp0 y
M8709 - Sturgell Res.
846709 V07
Valley 1 1
B48709059
Job Reference (optional)
Builders Fast5ouree, Plant Gliy, FL 33566 Run: 7.610 a Jan 292015 Penn: 7.61U s Jan 29 2015 WTek Industries, Inc. Tug Jul 26 21 U1:502016 P. 1
ID:oB3FwmhkmDDkA20AOICOM?yu7CB-aVnim?zpjvegOgBw?hOGs3O5jaTXFCKNV791guyu5C?
468 8-0-0 11-5-8 16.0-0
4.6-8 3-5-e 3-5.8 4-6.8
Scale =125.3
4x5 _ _ 2x4 11 4x6.-
...," r 2 3 4 _
3x4 4 8 7 6 3x4 O
2x4 II 20 II 2x4 II
LOADING (psf)
TCLL 20.0
TCDL 7.0
SCLL 0.0
BCDL . 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC20147TP12007
CSI.
TC 0.23
BC 0.19
INS 0.08
(Matrix)
DEFL in
Vert(LL) n/a
Vert(TL) n/a
Horz(TL) 0.00
floc) Well L/d
- n/a 999
- n/a 999
5 n/a n/a
PLATES GRIP
MT20 2441190
Weight: 551b FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
• WEBS 2x4 SP No.3
Mi fek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. All bearings 15-11-0.
• (lb) - Max Hom I=44(LC 9)
Max Uplift All uplift 100 Ito or less at joint(s) 1, 5 except 8=-134(LC 12), 6=-126(LC 13), 7=-160(LC
9)
Max Gmv All reactions 250 Ito or less at joints) 1, 5 except 8=289(LC 1), 6=289(LC 1), 7=256(LC 25)
FORCES. (Ib) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 2-8— 223/260, 4-6=223/260, 3-7=-226/273
NOTES (9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind; ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. 11; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Extedor(2) zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL-1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcunent with any other live loads.
6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except 01=1b)
8-134, 6-126, 7=160.
8) "Semi -rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
9)'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code'
LOAD CASE(S) Standard
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559
,}�' Q���• �%GC�E
,d ;•• STATE OF
9 • Q�
08/25/2016
Job was
Inuss lype Fly
U8709 - Slurgell Res.
UB709 VOB
vahey 5 1
848709060
Job Reference (optional)
.1 uty, IL a bb5 Run: 7.610 s Jan 29 2015 Pnnt: 7.610 s Jan 29 2015 YsTek Industries, he. Tus Jul 2621311.51 2016 Page 1
ID:oB3FwmhkmDOkA20AOiCOM?yu7CB-3hL4zL_RUCmXl zm6YOvVOGwJB_sH_grXknusCKyuSC_
Scale - 1:7.6
20 '-
LOADING (psf)
SPACING- 2-0-0
CSI.
DER...
in (loc)
Well
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.05
Ve art
n/a -
n1a
999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.03
Vert(TL)
n/a -
n/a
999
SCLL 0.0 '
Rep Stress Incr YES
WS 0.00
Horz(Q
-0.00 2
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
Weight: 5 lb FT=20%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.3
BRACING-
TOPCHORD
BOTCHORD
REACTIONS. (lb/size) 1=5111-11-8 (min. 0-1-8).2=37/1-11-8 (min. 0-1-8),3=14/1-11-8 (min.0-1-8)
Max Horz 1=39(LC 12)
Max Upliftl=-19(LC 12), 2--42(LC 12)
Max Grav 1=51(LC 1), 2-37(LC 1), 3=27(LC 3)
FORCES. (Ib) - Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
Structural wood sheathing directly applied or 2-0-0 oc puffins
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during tmss erection, in accordance with Stabilizer
Installation guide.
NOTES (8)
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL-4.2psf; BCDL=3.Opsf; h-15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Extedor(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
4)' This truss has been designed for a live load of 20.Opst on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verity capacity of
bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joints) 1, 2.
7)'Semi-rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
8) This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.'
LOAD CASE(S) Standard
W.
STATE OF
0,LOF1101"
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, FI 33559 08/25/2016
o N55
NSa ype y
BCB]a9-aNr9ell R.S.
848]09 V09
VaOey 3 1
849]o9061
Job Reference (optional)
mumem nrsnource, Part u1y, PLa3556
2x4 G
ME
s 2101:51 2016 Page t
_rc_f9Xknu.CKA5C_
Scale=1:11.3
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL
in (too) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.11
Vert(LL)
n/a - n/a 999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.07
Vert(TL)
n/a - n/a 999
BCLL 0.0 '
Rep Stress [nor YES
W B 0.11
Hom(TL) -0.00 3 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix)
Weight: 11 lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No-2
TOP CHORD
Structural wood sheathing directly applied or 3-6-0 oc pudins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (lb/size) 1=69/3-5-8 (min. 0-1-8), 3= 34/3-5-8 (min. 0-1-8), 4=-14/3-5-8 (min. 0-1-8), 5=191/3-5-8 (min.0-1-8)
Max Harz 1-80(LC 12)
Max Upliftl=-12(LC 12), 3=-34(LC 1), 4=-29(LC 3), 5=-141(LC 12)
Max Grav 1=69(LC 1), 3=39(LC 12), 5=191(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-5=-217/364
NOTES- (8)
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15tt; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Bearing at joint(s) 3 considers parallel to grain value using ANSVrPI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4 except (jt=lb)
5=141.
7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8)'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.'
LOAD CASE(S) Standard
♦v v.......... 4-1
STATE OF
y0'P�c..'e40RIDP �x���♦
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, Fl 33559 08/25/2016
Job Truss
Inass lype Ply
M8709-SWrgell Res.
848709 vlo
Valley 1 1
M8709062
Job Reference (optional)
echoers VescOUree, Vlant Glty, FL 33566
2x4 i 2x4 It
Scale =1:12.6
LOADING (psf)
SPACING- 2-0-0
CSI.
DER.
in (loc)
Udell
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.11
Ver U-)
n/a -
n/a
999
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.07
Vert(TL)
n/a -
n/a
999
BCLL 0.0 '
Rep Stress Incr YES
WB 0.10
Horz(fL)
-0.00 3
n/a
n/a
-
BCDL 10.0
Code FBC2014rrP12007
(Matrix)
Weight: 131b FT=20%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3
REACTIONS, Allbearings3-11-8.
(Ib) - Max Horz 1=94(LC 12)
" Max Uplift All uplift 100 lb or less atjoint(s) 1, 3 except 5_ 130(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 1, 3, 4, 5
FORCES. (lb) - Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
WEBS 2-5=-199/334
BRACING -
TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purl ins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES- (8)
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) Gable requires continuous bottom chard bearing.
3) This truss has been designed for a 10.0 pat bottom chord live load nonconcunenl with any other live loads.
4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Bearing at joint(s) 3 considers parallel to grain value using ANSVrPI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)1, 3 except (jt=lb)
5-130.
7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building Is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.'
LOAD CASE(S) Standard
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559
Q�'�,iC'EMSF'9!!•�Q
.q STATE OF ; C
�A461 or
08/25/2016
Job Truss
I Was I ype y
M709-Sturgell Res.
818709 Vil
Valley 1 1
848709063
Job Reference (optional)
BUUders FirstBource, Plant City, RM566
5 4
2x4 o ass 11
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL
in (loc)
Well
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.40
Ve t(LL)
n/a -
n/a
999
TCDL 7.0
Lumber DOL
1.25
BC 0.25
Vert(Q
n/a -
n/a
999
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.20
Hom(TL)
-0.00 3
n/a
n/a
BCDL 10.0
Code FBC20141TPI2007
(Matrix)
LUMBER- BRACING-
Scale=1:17.8
PLATES GRIP
MT20 244/190
Weight: 21 lb FT-20%
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3 MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (lb/size) 1=127/5-11-8 (min. 0-1-8),3=-66/5-11-8 (min. 0-1-8), 4=-25/5-11-8 (min. 0-1-8),5=360/5-11-8 (min.0-1-8)
Max Horz 1=150(LC 12)
Max Upliftl= 20(LC 12), 3=-66(LC 1), 4=-51(LC 3), 5=-268(LC 12)
Max Grav 1=127(LC 1), 3=75(LC 12), 5=360(LC.1)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 2-5= 407/676
NOTES (8)
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2ps1; BCDL=3.Opsf; h=15ft, Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Extedor(2) zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL-1.60
2) Gable requires continuous bottom chard bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcunent with any other live loads.
4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Bearing at joints) 3 considers parallel to grain value using ANSVTP11 angle to grain formula. Building designer should verify capacity of
bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4 except 0t=11b)
5=268.
7) "Semi -rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
8) -This manufactured product is designed as an individual building component The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.'
LOAD CASE(S) Standard
�icefusF.,�� 'e
STATE OF
i
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016
Scale -1 22.9
5 4
3x6 i a4 II
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL
in (loc)
Vdefi
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.45
Ven(LL)
n1a -
n/a
999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.62
Vert(TL)
n/a -
n/a
999
BCLL 0.0 '
Rep Stress Incr YES
W B 0.19
Horz(TL)
-0.00 3
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
Weight: 281b FT-20%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
BOT CHORD
REACTIONS. All bearings 7-11-8.
(lb) - Max Horz 1=206(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) 1, 3, 4 except 5=-304(LC 12)
Max Gmv All reactions 250 lb or less at joints) 1, 3, 4 except 5=407(LC 1)
FORCES. (lb) - Max. Comp.Mlax. Ten. - All tomes 250 (lb) or less except when shown.
TOP CHORD 1-2--308/139
WEBS 2-5=408/629
Structural wood sheathing directly applied or 6-0-0 oc purlins
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES (8)
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsh h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Bearing at joints) 3 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4 except jWb)
5=304.
7)'Semi-rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code. -
LOAD CASE(S) Standard
STATE OF
�70f,' .. 0.RI0P.
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016
r
Dc4 7 6 5
2x411 a4 II
Scale=1:25.7
LOADING (par)
SPACING- 2-0-0
CS].
DEFL
in floc)
Well
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.32
Vert(LL)
n/a -
n/a
999
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.33
Vert(FL)
n/a -
n/a
999
BCLL 0.0 '
Rep Stress Incr YES
WB 0.17
Hom(TL)
-0.00 4
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
Weight: 39 lb FT-20%
LUMBER- BRACING
TOP CHORD 2x4 SP No.2 TOP CHORD
BOT CHORD 2x4 SP No.3 BOT CHORD
WEBS 2x4 SP No.3
REACTIONS. All bearings 9-11-8.
(lb) - Max Horz 1=261(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) 4, 5 except 7= 272(LC 12), 6=-163(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 1, 4, 6 except 7=364(LC 1)
FORCES. (Ib) - Max. Comp./Max. Ten. -All forces 250 fib) or less except when shown.
TOP CHORD 1-2=438/170
WEBS 2-7=-368/557,3-6=-243/380
Structural wood sheathing directly applied or 6-0-0 oc purlins
Rigid ceiling directly applied or 10-0-0 oc bracing.
Mi fek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation puitle.
NOTES- (8)
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Extedor(2) zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Bearing at joints) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5 except ft=lb)
7=272, 6=163.
7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular
building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code"
LOAD CASE(S) Standard
W.
�N40d ,(A
„o ;• 5TATE OF �•Q,
Robert W. Wall, PE 46021
24710 State Road 54 Lutz, F133559 08/25/2016