HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online
Page 1 of 5
n kilfli
EMS Home i Log In I User Registration I Hot Topla I Submit Surtba UP'
Y
ons I contod Us 1 BUS Site Map I ❑nks Sea h 1
db r FILE
j�� Product Approval `f� USER: Wblic User
Proautt Approval Menu> pmautt o, Application Search > ponlica Ian Lst> Appllranan aefdlr{ i �I. 1 \ 1
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
CONCEALED f5f?*TACHMENTS
ARETHE RESPONSIBIU IY OF THE
1110-WRRACTOR OR RECORD
Authorized Signature
FL11651-R3
Revision
ST. LUCIE
2017
REVIEWEC
Approved
REVIEWEC
rLHNs AND PERMIT MUST BE
SITE OR NO INSPECTIONS) I
Gulf Coast Supply & Manufacturing, LLC.
4020 S. W. 449th Street
Horseshoe Beach, FL 32648
(352) 498-0778
info@gulfcoastsupply.com
Eng David
info@gulfcoastsupply.com
1b19T
SCANNED
BY
St. Lucie County
Technical Representative
David Eng
THESE PIANSANDALL PROPOSED WORK
Address/Phone/Email
14429SW2ndPi
SteG30 ARE SUBJECTTO ANY CORRECTIONS
Newberry, FL 32669 REWMED BYFIELD INSPECTORSTHAT
(352) 498-0778 info@gulfcoastsupply.corVY BE NECESSARY IN ORDER TO
info@gulfcoas[supply.corrMPLY CODES.
WITH ALL APPLICABLE
Quality Assurance Representative
David Eng
Address/Phone/Email
14429 SW 2nd PI
Ste G30
Newberry, FL 32669
(352) 498-0778
david.eng@gulfcoastsupply.com
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Daniel S. Kuhn
the Evaluation Report
Florida License PE-75519
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/12/2024
Validated By Locke Bowden P.E.
Certificate of Independence
RJ Validation Checklist - Hardcopy Received
FL11651 R3 COI Cert of independence 2017-10-09.odf
Referenced Standard and Year (of Standard) Standard
FM 4471
TAS 100
TAS 110
TAS 125
UL 1897
UL 580
Year
1992
1995
2000
2003
2012
2006
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2fI'rZeCS... 3/18/2019
Florida Building Code Online
Page 2 of 5
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Go to Page = ir''
f—�
Method 1 Option D
10/10/2017
10/12/2017
10/17/2017
12/12/2017
0 4) Page l / 2 0
FL #
Model, Number or Name
Description
11651.1
0.032" Aluminum SV Crimp
Min 0.032" 5 V Crimp Aluminum Roof Panel over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL11651 R3 II FL11651 1 R3 Metal Roof Panel Detail -
sianed.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-108.SPSF
Created by Independent Third Party: Yes
Other: -108.5 psf @ 12" o.c. Install per manufacturers
Evaluation Reports
details. Not for use in HVHZ Zones.
FL11651 R3 AE FL11651 1 R3 0325vCrimo 15-
32Plvwood NonHVHZ-sioned.odf
Created by Independent Third Party: Yes
11651.2
0.032" Aluminum Gulf Lok
Min 0.032" Aluminum Gulf Lok 16" Wide Roof Panel over
15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Na
FL11651 R3 11 FL11651 2 R3 Metal Roof Panel DQLaL
sianed.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-116.OPSF
Created by Independent Third Party: Yes
Other: -52.5 psf @ 5 3/16" o.c. fastener spacing. -116.0 psf
Evaluation Reports
@ 5 3/16" o.c. fastener spacing. Install per manufacturers
FL11651 R3 AE FL11651 2 R3 032GulfLok 16 15-
32Plvwood NonHVHZ-sioned.odf
details. Not for use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.3
1" 24ga. Gulf Snap
1" Gulf Snap 24 Ga. 17" wide Roof Panel over 15132" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R3 iI FL11651 3 R3 Metal Roof Panel Detail -
signed pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/--131.OPS
Created by Independent Third Party: Yes
Other: -67.3 psf @ 24" o.c. clip spacing. -131 psf @ 6" o.c.
Evaluation Reports
clip spacing. Install per manufacturers details. For use in
F 11651 93 AE EL11651 3 R3 I 24GkillSnap
32Plvwood HVHZ-signed.pdf
HVHZ Zones.
Created by Independent Third Party: Yes
11651.4
1" 24ga. VersaLoc
I" VersaLoc 24ga 16.5" Wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R3 II FL11651 4 R3 Metal Roof Panel Detall-
signed.odF
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-138.5PSF
Created by Independent Third Party: Yes
Other: -71 psf @ 24" o.c. clip spacing. -138.5 psf @ 6" o.c.
Evaluation Reports
clip spacing. Install per manufacturers details. For use in
FL11651 R3 AE FL11651 4 R3 24Versal-oc SR 16.5 IS-
32Plvwood HVHZ-signed.pdf
HVHZ Zones.
Created by Independent Third Party: Yes
11651.5
1" VersaLoc .032" Aluminum
1" VersaLoc min .032" Aluminum over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL11651 R3 II FL11651 5 R3 Metal Roof Panel Detail -
signed.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-101.OPSF
Created by Independent Third Party: Yes
Other: -63.3 psf @ 24" o.c. clip spacing. -101.0 psf @ 6"
Evaluation Reports
o.c. clip spacing. Install per manufacturers details. For use in
FL11651 R3 AE FL11651 5 R3 Iin 032Versai-oc
SR 16 15-32Plvwood HVHZ-sioned.odf
HVHZ Zones.
Created by Independent Third Party: Yes
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K`/o2frrZeCS... 3/18/2019
Florida Building Code Online
Page 3 of 5
11651.6
1.5" 24ga. Gulf Snap
1.5" Gulf Snap 24ga. 16" Wide Roof Panel over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-116.0PSF
Other: -86.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
O.C. clip spacing. -116.0 psf @ 6" o.c. clip spacing. Install per
manufacturers detals, For use in HVHZ Zones.
EL11651 R3 II FL11651 6 R3 Metal Roof Panel De[ 'I -
sianed.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 6 R3 1.5 24Gulf5nao 16 15-
32Plvwood HVHZ-sionedodf
Created by Independent Third Party: Yes
11651.7
1.5" 24ga. VersaLoc
1.5" VersaLoc min 24ga. 16" wide Roof Panel over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
FL11651 R3 II FL11651 7 R3 Metal Roof Panel D ta'I-
sianed.odf
Impact Resistant: N/A
Design Pressure: +N/A/-123.5PSF
Other: -59.75 psf @ 24" o.c. clip spacing. -123.5 psf @ 12"
o.c. clip spacing. Install per manufacturers details. For use in
HVHZ Zones.
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 7 R3 1.5 24VersaLo 16 IS-
32Plvwood HVHZ-s'oned odf
Created by Independent Third Parry: Yes
11651.8
2" 24ga. MegaLoc
Min 24 Ga. 2" MegaLoc 18" wide Roof Panel over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-308.SPSF
Other: -71.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
o.c. clip spacing. Install per manufacturers details. Not for
use in HVHZ Zones.
FL11651 R3 II FL11651 8 R3 Metal Roof Panel Deis
signed odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Parry: Yes
Evaluation Reports
FL11651 R3 AE FL11651 8 R3 24Versal-c 18 15-
32Plywood N HVHZ-s'oned df
Created by Independent Third Party: Yes
11651.9
24 Ga. Gulf Lok
Min 24 Ga. Gulf Lok 16" Wide over 15/32" Plywood
Limps of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL11651 R3 II FL11651 9 R3 Metal Roof Panel Detail -
signed odf
Impact Resistant: N/A
Design Pressure: +N/A/-96.7PSF
Other: -81.75 psf @ 10-1/4" o.c. fastener spacing. -96.76
psf @ 5-1/8" o.c. fastener spacing.-121.75 psf @ 5-1/8"
fastener spacing. -161 psf @ 5-118" fastener spacing. Install
per manufacturers details. Not for use in HVHZ Zones.
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 9 R3 24 IfLok -16 1
32Plvwood NonHVHZ-signed odf
I Created by Independent Third Party: Yes
11651.10
24 Ga. Gulf Seam
Min 24 Ga. Gulf Seam 16" Wide Roof Panel over Ix4 Wood
Purlins over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL11651 R3 It FL11651 10 R3 Metal Roof Panel Detail -
sioned.odf
Impact Resistant: N/A
Design Pressure: +N/A/-93.5PSF
Other: -93.5 psf @ 18" o.c. Install per manufacturers
details. Not for use in HVHZ Zones.
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 10 R3 24GulfSeam 16 Ix4 15-
32Plywood NonHVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.11
24 Ga. Gulf Seam
Min 24 Ga. Gulf Seam, 1 3/4" Snap Lock, 18" Wide Roof
Panel over 15/32" Plywood
Limps of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R3 II FL11651 11 R3 Metal Roof Panel Deta'I-
Approved for use outside HVHZ: Yes
sianed.odf
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-108.5PSF
Other: -69.25 psf @ 24" O.C. clip spacing. -108.5 psf @ 12"
o.c. clip spacing. Install per manufacturers details. Not for
use in HVHZ Zones.
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 11 R3 24GulfSeam 18 15-
32Plvwood NonHVHZ-signed odf
Created by Independent Third Parry: Yes
11651.12
26 Ga. 5V Crimp
Min 26 Ga. 5V Crimp Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
1`1-31651 R3 II FL11651 12 R3 Metal Roof Panel Detail -
siangd.Ddf
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-156.5PSF
Other: -108.5 psf @ 12" O.C. fastener spacing. -156.5 psf @
6" o.c. fastener spacing. Install per manufacturers details. For
use in HVHZ Zones.
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 93 AE FL11651 12 R3 265vCrlmp IS -
https://floridabuilding.org/prlpr_app_dtl.aspx?param=wGEV XQwd)gsQFc5K`/`2ffrZeCs... 3/18/2019
Florida Building Code Online Page 4 of 5
22P]Ywood HVHZ-s'oned Ddf
Created by Independent Third Party: Yes
11651.13
26 Ga. 5V Crimp
Min 26 Ga. 5V Crimp over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL11651 R3 II FL11651 13 R3 Metal Roof Panel Detail -
sianed.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-131.PSF
Other: -94.25 psf @ 16" o.c. fastener pattern. -131.0 psf @
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
16" o.c, fastener pattern. Install per manufacturers details.
Not for use in HVHZ Zones.
FL11651 R3 AE FL11651 13 R3 265 C' D IS -
32Plvwood NonHVHZ-sinned.Ddf
Created by Independent Third Party: Yes
11651.14
26 Ga. 5V Crimp
Min 26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purllns over
15/32" Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL11651 R3 II FL11651 14 R3 Metal Roof Panel Detail -
sioned.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-156.5PSF
Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @
Created by Independent Third Party: Yes
Evaluation Reports
6" o.c. fastener spacing. Install per manufacturers details. For
FL11651 R3 AE FL11651 14 R3 265vCr'mo 1x4 IS -
32Plvwood NonHVHZ-sinned odf
use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.15
26 Ga. Gulf Lok
Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL1_1651 R3 11 FUI651 15 R3 Metal Roof Panel Detail -
sened.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-161.OPSF
Created by Independent Third Party: Yes
Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75
Evaluation Reports
psf @ 5 3/16" spacing. -161.0 psf @ 5 3/16" o.c. fastener
FL11651 R3 AE FL11651 15 R3 2601IfLok 16 15-
spacing. Install per manufacturers details. For use in HVHZ
32Plvwood HVHZ-slonetl odf
Zones.
I Created by Independent Third Party: Yes
11651.16
26 Ga. Gulf Lok
Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL11651 R3 II FL11651 16 R3 Metal Roof Panel Detail -
sianed.ndf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verifed By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-63.5PSF
Created by Independent Third Party: Yes
Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75
Evaluation Reports
psf @ 5 3/16" fastener spacing. -161 psf @ 5 3/16" fastener
FL11651 R3 AE FL11651 16 R3 26Gr Ifl-ok 16 15-
32Plvwood NonHVHZ-sianed.Ddf
spacing. Install per manufacturers details. Not for use in
HVHZ Zones.
Created by Independent Third Party: Yes
11651.17
26 Ga. GulfPBR
Min 26 Ga. Gulf PBR Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
EL11651 R3 IT EL11651 17 R3 Metal RoofPanel Detailw
sianed.odf
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-154.7PSF
Created by Independent Third Party: Yes
Other: -59.25 psf @ 24" O.C. fastener pattern.-154.75 psf
Evaluation Reports
@ 12" o.c. fastener pattern. Install per manufacturer details.
FL11651 R3 AE FL11651 17 R3 26GuIfPBR IS -
32Plvwood NonHVHZ-sianed.odf
Not for use in HVHZ
Created by Independent Third Party: Yes
11651.18
26 Ga. GulfPBR
Min 26 Ga. GulfPBR Roof Panel over Ix4 Wood Purlins over
15/32" Plywood
Limps of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL11651 R3 II FLA1651 III R3 Metal Roof Panel Dotal -
sioned.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-151.7PSF
Created by Independent Third Party: Yes
Other: -100.5 psf @ 24" o.c. fastener spacing.-151.75 psf
Evaluation Reports
@ 12" fastener spacing. Install per manufacturer's details.
FL11651 R3 AE FL1165118 R3 26GUIfPBR IX4
32Plvwood HVHZ-sianed.odf
For use In HVHZ Zones
Created by Independent Third Party: Yes
11651.19
26 Ga. GulfPBR
Min 26 Ga. GulfPBR over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL11651 R3 II FL11651 19 R3 Metal Roof Panel Detail -
sianed.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-154.7PSF
Created by Independent Third Party: Yes
Other: -60.5 psf @ 24" o.c. fastener spacing.-154.75 psf @
Evaluation Reports
FL11651 R3 AE FL11651 19 R3 26GulfPBR 15-
https://floridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2frrZeCS... 3/ 18/2019
Florida Building Code Online
Page 5 of 5
12" o.c. fastener spacing. Install per manufacturer's details.
32Plvwood HVHZ-s'oned.odf
For use in HVHZ Zones.
Created by Independent Third Parry: Yes
11651.20
26 Ga. GulfPBR
Min 26 Ga. GulfPBR over Ix4 Wood Purllns over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R3 II FL11651 20 R3 Metal Roof Panel Detail -
sianed.Ddf
Approved for use outside HVHZ: Yes
Impact_ Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: 1N/A/-151.7PSF
Created by Independent Third Party: Yes
Other: -94.25 psf @ 24" o.c. fastener spacing.-151.75 psf
Evaluation Reports
@ 12" fastener spacing. Install per manufacturer's details.
FL11651 R3 AE FL11651 20 R3 26GulfPBR 1x4 IS -
32Plvwood NOnHVHZ-sianed.odf
Not for use In HVHZ Zones
Created by Independent Third Party: Yes
Go to Page ':.�' 'Ll Page 1 / 2 to
Back Next
contact US;: 2601 Blair Stone Road, Tallahassee R 32399 Phone: 850-487-1824
The State of Florida is an AA/EM employer. rnovrlaht 2007-2013 State of Herida.:: Privacy Statement:: Accessibility Statement:: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electinnle
mall to this entity. Instead, contact the office by phone or by tadltlonal mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department with an email address if they have one. The
emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public To determine if you are a licensee under chapter 455, F.S., please
click here .
produce Approval Accepts:
F;'jiq 0
Credit Card
Safe
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5KOlo2frrZeCS... 3/ 18/2019
.Florida Building Code Online
Page 1 of 2
Fig
BQS Home ? Log In I User Regisuation I Hot Topim I Submit Surcharge I scats&Facts I Publications I Coruna us I Scls site taep I Hnks search
Ronda FILE- COPY
!; ' Product Approval
, pr p. USER: Publk User —�
Cr1��
Pautt pooroval Menu Aonii[anSearclU >poolicaon Lut>Applktl aon DBtafl�
mmtttlo
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL16048-R6
Revision
2017
Approved
IN
Tri-Built Materials Group, LLC
PO Box 70
Rutherford, NJ 07070
(800) 516-1485
david.ruiz@tribuiltmg.com
David Ruiz
david.miz@tribuiltmg.com
David Ruiz
250 Route 17 North
East Rutherford, NJ 07073
(201) 842-2449
david.rulz@tribuiltmaterlaisgroup.com
Roofing
Underlayments
SCANNED
BY
St. Lucie County
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
PE-59166
UL LLC
07/18/2020
John W. Knezevich, PE
96 Validation Checklist - Hardcopy Received
FL16048 R6FL16048 R6 COI 201701 COI Nieminen.odf2017 01 COI Nieminen.odf
Standard
ASTM D1970
ASTM G155
FM 4474
FRSA/TRI April 2012 (04-12)
UL 1897
Year
2015
2005
2011
2012
2012
https://floridabuilding.org/t)r/pr_app_dtl.aspx?param=wGEV XQwtDgtFPmdYiND Wrwip... 3/ 18/2019
Florida Building Code Online
Page 2 of 2
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
r— I
Method 1 Option D
09/25/2017
10/01/2017
10/03/2017
12/12/2017
FL #
Model, Number or Name
Description
16048.1
TRI-BUILT Roof Underlayments
Self -adhering, modified bitumen roof underlayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
1`1,16048 R6 11 2017 09 FINAL ER TRI-
Approved for use outside HVHZ: Yes
BUILT UNDERLAYMENTS FL16048-R6 pdf
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-150
Created by Independent Third Party: Yes
Other: 1.) The design pressure noted herein pertains to use
Evaluation Reports
of foam -on tile systems overtop the self -adhering
FL16048 R6 AE 2017 09 FINAL ER TRI-
underlayment for ane particular application. See ER Section
BUILT UNDERLAYMENTS FL36048-R6.pdf
5.6.4 for details. 2.) Refer to ER Section 5 for other Limits of
Created by Independent Third Party: Yes
Use.
Back Na#
coma :: 2601 Blair Stone Road, Tallahassee FL 32399 phone: 850-487-1824
The State of Florida is an AA/EEO employer. Cowricht 2007-2013 State of Florida.:: Privacy Statement :: Acresslbllity Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electrom,
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please tunas 850.487.1395. *Pursuant to section 455.275
(1). Flprida Statutes, eNeUNe October 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department with an emall address if they have one. Tm
emails provided my be used for official communication with the licensee. However emall addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under chapter 455, F.S., please
ai&n=.
Product Approval Accepts:
® ® 99 M
Credit Card
Safe
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtFPmdYiND Wrwip... 3/ 18/2019