HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online
Page 1 of 5
8CIS Home Log In j User Registration Hot Top1m I Submit Sumhame I Sets & Fatts j Publication:
dhpr FILE COP
g; "a Product Approval
USER:-PublkUser I{ 4` � �.[J)
ProtluR Aoorova Men > Eutt o, N li a, >pp p p¢ �IF/ �� I
FL #
FL11651-R3
Application Type
Revision
SCANNED
Code Version
2017
Application Status
Approved
BY
St. Lucie County
Comments
Archived
❑
Product Manufacturer
Gulf Coast Supply & Manufacturing,
LLC.
Address/Phone/Email
4020 S. W. 449th Street
Horseshoe Beach, FL 32648
(352) 498-0778
info@gulfcoastsupply.com
Authorized Signature Eng David
info@gulfcoastsupply.com
Technical Representative David Eng
Address/Phone/Email 14429 SW 2nd PI
Ste G30
Newberry, FL 32669
(352) 498-0778
info@gulfcoastsupply.com
Quality Assurance Representative David Eng
Address/Phone/Email 14429 SW 2nd PI
Ste G30
Newberry, FL 32669
(352) 498-0778
david.eng@gulfcoastsupply.com
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed
Daniel S. Kuhn
the Evaluation Report
Florida License
PE-75519
Quality Assurance Entity
Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date
04/12/2024
Validated By
Locke Bowden P.E.
R5 Validation Checklist - Hardcopy Received
Certificate of Independence FL11651 R3 COI Cert of Independence 2017-10-09 odf
Referenced Standard and Year (of Standard) _ Standard
Year
' FM 4471
1992
TAS 100
1995
TAS 110
2000
TAS 125
2003
UL 1897
2012
UL 580
2006
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2fI'rZeCS... 3/18/2019
rlorida Building Code Online
Page 2 of 5
Equivalence of Product Standards
Certified By
Sections from the Code
Product ApprovalMethod
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Go to Page
Method 1 Option
10/10/2017
10/12/2017
10/17/2017
12/12/2017
04 Pagel/200
FL #
Model, Number or Name
Description
11651.1
0.032" Aluminum SV Crimp
Min 0.032" 5 V Crimp Aluminum Roof Panel over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R3 II FL11651 1 R3 Metal Roof Panel Deta'I-
Approved for use outside NVHZ: Yes
sc ned gdf
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-108.5PSF
Created by Independent Third Party: Yes
Other: -108.5 psf @ 12" O.C. Install per manufacturers
Evaluation Reports
details. Not for use in HVHZ Zones.
FL11651 R3 AE FL11651 1 R3 0325vCrimo IS-
32Plvwood NonHVHZ-signed odf
Created by Independent Third Party: Yes
11651.2
0.032" Aluminum Gulf Lok
Min 0.032" Aluminum Gulf Lok 16" Wide Roof Panel over
15/32" Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL11651 R3 11 FL11651 2 R3 Metal Roof Panel Deta'I-
sioned.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-116.OPSF
Created by Independent Third Party: Yes
Other: -52.5 psf @ 5 3/16" o.c. fastener spacing. -116.0 psf
Evaluation Reports
@ 5 3/16" O.C. fastener spacing. Install per manufacturers
FL11651 R3 AE FL11651 2 R3 032Gulf-ok 16 15-
details. Not for use in HVHZ Zones.
32PIvwood N HVHZ- ' ned odf
Created by Independent Third Party: Yes
11651.3
1" 24ga. Gulf Snap
1" Gulf Snap 24 Ga. 17" wide Roof Panel over 15/32" Plywood
Limps of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R3 11 FL11651 3 R3 Metal Roof Panel Detail -
sianetl odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/--131.OPS
Created by Independent Third Party: Yes
Other: -67.3 psf @ 24" o.c. clip spacing. -131 psf @ 6" o.c.
Evaluation Reports
clip spacing. Install per manufacturers details. For use in
FL11651 R3 AE FL11651 3 R3 1 24Gulf5nao 17 IS-
32Plvwootl HVHZ-sioned.odf
HVHZ Zones.
Created by Independent Third Party: Yes
11651.4
1" 24ga. VersaLoc
1" VersaLoc 24ga 16.5" Wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
ApprovedforuseoutsideHVHZ:Yes
FL11651 R3 II FL11651 4 R3 Metal Roof Panel Detell-
signed.rdf
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/Ar-138.5PSF
Created by Independent Third Parry: Yes
Other: -71 psf @ 24" O.C. clip spacing. -138.5 psf @ 6" o.c.
Evaluation Reports
clip spacing. Install per manufacturers details. For use in
FLI 1651 R3 AE FL11651 4 R3 24Versal-oc SR 16.5 IS-
32Plvwootl HVHZ-signed.9cI
HVHZ Zones.
Created by Independent Third Party: Yes
11651.5
1" VersaLoc .032" Aluminum
1" VersaLoc min .032" Aluminum over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL11651 R3 II F01651 5 R3 Metal Roof Panel Detall-
soned.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-101.OPSF
Created by Independent Third Party: Yes
Other: -63.3 psf @ 24" o.c. clip spacing. -101.0 psf @ 6"
Evaluation Reports
o.c. clip spacing. Install per manufacturers details. For use in
FL11651 R3 AE FL11651 5 R3 tin 032VersaLoc
SR 16 15-32Plvwootl HVHZ-sianetl odf
HVHZ Zones.
Created by Independent Third Party: Yes
https://floridabuilding.org/prlpr_app_dtl.aspx?param=wGEV XQwtDgsQFc5K`/d2frrZeCS... 3/18/2019
Vlorida Building Code Online
Page 3 of 5
11651.6
1.5" 24ga. Gulf Snap
1.5" Gulf Snap 24ga. 16" Wide Roof Panel over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
for use outside HVHZ: Yes
FL11651 R3 II FL11651 6 R3 Metal Roof Panel DiataLApproved
signed odf
Impact Resistant: N/A
Design Pressure: +N/A/-116.0PSF
Other: -86.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
o.c. clip spacing. -116.0 psf @ 6' o.c. clip spacing. Install per
manufacturers detals. For use in HVHZ Zones.
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Parry: Yes
Evaluation Reports
FL11651 R3 AE FL11651 6 R3 1.5 24GL11fSnap 16 15-
32Plvwood HVHZ=slanetl DdF
Created by Independent Third Party: Yes
11651.7
1.5" 24ga. VersaLoc
1.5" VersaLoc min 24ga. 16" wide Roof Panel over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL11651 R3 ii FL11651 7 R3 Metal Roof Panel D t II -
signed.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 7SS19
Design Pressure: +N/A/-123.SPSF
Other: -59.75 psf @ 24' o.c. clip spacing. -123.5 psf @ 12"
o.c. clip spacing. Install per manufacturers details. For use in
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 7 R3 1.5 24VersaLoc 16 15-
32Plvwood HVHZ-sianed odf
HVHZ Zones.
Created by Independent Third Party: Yes
11651.8
2" 24ga. MegaLoc
Min 24 Ga. 2" MegaLoc 18" wide Roof Panel over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL11651 R3 II FL11651 8 R3 Metal Roof Panel Detail -
sioned.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-10B.SPSF
Other: -71.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
Created by Independent Third Party: Yes
Evaluation Reports
o.c. clip spacing. Install per manufacturers details. Not for
FL11651 R3 AE FL11651 8 R3 24VersaLoc 18 15-
32Plvwood NonHVHZ-sianed odf
use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.9
24 Ga. Gulf Lok
Min 24 Ga. Gulf Lok 16" Wide over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL11651 R3 II FL11651 9 R3 Metal Roof Panel Detail -
Approved for use outside HVHZ: Yes
signed odf
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-96.7PSF
Other: -81.75 psf @ 10-1/4" o.c. fastener spacing. -96.76
Created by Independent Third Parry: Yes
Evaluation Reports
psf @ 5-1/8" o.c. fastener spacing.-121.75 psf @ 5-1/8"
FL11651 R3 AE FL11651 9 R3 24GuIfl-ck 1 IS -
32Plvwood NonHVHZ-sianed Ddf
fastener spacing. -161 psf @ 5-1/8" fastener spacing. Install
per manufacturers details. Not for use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.10
24 Ga. Gulf Seam
Min 24 Ga. Gulf Seam 16" Wide Roof Panel over 1x4 Wood
Purlins over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL11651 R3 11 FL11651 10 R3 Metal Roof Panel Detall-
Approved for use outside HVHZ: Yes
sioned.odf
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-93.5PSF
Other: -93.5 psf @ 18" o.c. Install per manufacturers
Created by Independent Third Party: Yes
Evaluation Reports
details. Not for use in HVHZ Zones.
FL11651 R3 AE FL11651 10 R3 24GulfSeam 16 1 4 15-
32Plywood NonHVHZ-sia ed odf
Created by Independent Third Party: Yes
11651.11
24 Ga. Gulf Seam
Min 24 Ga. Gulf Seam, 1 3/4" Snap Lock, 18" Wide Roof
Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R3 IT FL11651 11 R3 Metal Roof Panel Detail -
signed.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-108.SPSF
Created by Independent Third Party: Yes
Other: -69.25 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
Evaluation Reports
o.c. clip spacing. Install per manufacturers details. Not for
FL11651 R3 AE FL11651 11 R3 24GulfSeam 18 IS -
32Plvwood NonHVHZ-sianed DdF
use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.12
26 Ga. 5V Crimp
Min 26 Ga. 5V Crimp Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL11651 R3 II FL11651 12 R3 Metal Roof Panel Detail -
sianed odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-156.5PSF
Created by Independent Third Party: Yes
Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @
Evaluation Reports
6" o.c. fastener spacing. Install per manufacturers details. For
FL11651 R3 AE FL11651 12 R3 265vC im 15-
use in HVHZ Zones.
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5KOlo2ffrZeCS... 3/18/2019
k ionaa tsunaing uoae unline
Page 4 01 S
32Plvwood HVHZ-sonedodf
Created by Independent Third Party: Yes
11651.13
2fi Ga. 5V Crimp
Min 26 Ga. 5V Crimp over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL11651 R3 II FL11651 13 R3 Metal Roof Panel Detail -
signed.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-131.PSF
Created by Independent Third Party: Yes
-Other: —94.25 psf @ 16" o.c. fastener pattern. -131.0 psf @
Evaluation Reports
16" o.c. fastener pattern. Install per manufacturers details.
FL11651 R3 AE FL11651 13 R3 265yCrimo 15-
32Plvwood NonHVHZ-signed.odf
Not for use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.14
26 Ga. 5V Crimp
Min 26 Ga. 5V Crimp Roof Panel over Sx4 Wood Purlins over
15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R3 11 FL11651 14 R3 Metal Roof Panel Detail -
signed.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-156.5PSF
Created by Independent Third Party: Yes
Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @
Evaluation Reports
6" o.c. fastener spacing. Install per manufacturers details. For
FLI 1651 R3 AE FL11651 14 R3 265vCrimo lx4 15-
32Plvwood NonHVHZ-sioned.odf
use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.15
26 Ga. Gulf Lok
Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood
Limps of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R3 11 FL11651 15 R3 Metal Roof Panel Detail -
sioned.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-161.OPSF
Created by Independent Third Party: Yes
Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75
Evaluation Reports
psf @ 5 3/16" spacing. -161.0 psf @ 5 3/16" o.c. fastener
FL11651 R3 AE FL11651 15 R3 26GulfLok 16 15-
32Plvwood HVHZ-signed.odf
spacing. Install per manufacturers details. For use in HVHZ
Zones.
Created by Independent Third Party: Yes
11651.16
26 Ga. Gulf Lok
Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL11651 R3 II FL11651 16 R3 Metal Roof Panel Detail -
signed.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-63.5PSF
Created by Independent Third Party: Yes
Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75
Evaluation Reports
psf @ 5 3/16" fastener spacing. -161 psf @ 5 3/16" fastener
FL11651 R3 AE FL11651 R3 26GulfLok 16 15-
32Plvwood NonHVHZ-signed.odf
spacing. Install per manufacturers details. Not for use In
HVHZ Zones.
Created by Independent Third Party: Yes
11651.17
126 Ga. GuIfPBR
Min 26 Ga. Gulf PER Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R3 11 FL11651 17 R3 Metal Roof Panel D tail
sloned.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-154.7PSF
Created by Independent Third Party: Yes
Other: -59.25 psf @ 24" o.c. fastener pattern.-154.75 psf
Evaluation Reports
@ 12" o.c. fastener pattern. Install per manufacturer details.
FL11651 R3 AE FL11651 17 R3 26GuIfPBR 15-
32Plvwood NonHVHZ-sianed.odf
Not for use in HVHZ
Created by Independent Third Party: Yes
11651.18
26 Ga. GuIfPBR
Min 26 Ga. GuIfPBR Roof Panel over 1x4 Wood Pudins over
15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R3 11 FL11651 18 R3 Metal Roof Panel Detail -
slgned.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-151.7PSF
Created by Independent Third Party: Yes
Other: -100.5 psf @ 24" o.c. fastener spacing.-151.75 psf
Evaluation Reports
@ 12" fastener spacing. Install per manufacturer's details.
FL11651 R3 AE FL11651 18 R3 26GuIfPBR Ix4 15-
32Plvwood HVHZ-sianed.odf
For use in HVHZ Zones
Created by Independent Third Party: Yes
11651.19
26 Ga. GulfPBR
Min 26 Ga. GuIfPBR over 15/32" Plywood
Limps of Use
Installation Instructions
Approved for use in HVHZ: Yes
16 1 R3 II FL11651 19 R3 Metal RoQf PaDelDetail-
signed.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-154.7PSF
Created by Independent Third Party: Yes
Other: -60.5 psf @ 24" o.c. fastener spacing.-154.75 psf @
Evaluation Reports
FL11651 R3 AE FL11651 19 R3 26GulfPBR 15-
https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsQFc5Kd/`2frrZeCS... 3/18/2019
Florida Building Code Online
Page 5 of 5
12" o.c. fastener spacing. Install per manufacturer's details.
32Plvwood HVHZ-signed odf
For use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.20
26 Ga. GuIfPBR
Min 26 Ga. GUIfPBR over 1x4 Wood Purlins over 15/32-
Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL11651 R3 II FL11651 20 R3 Metal Roof Panel Detail -
signed odf
Impact Resistant: N/A
Design Pressure: +N/A/-151.7PSF -
Other: -94.25 psf @ 24" o.c. fastener spacing.-151.75 psf
@ 12' fastener spacing. Install per manufacturer's details.
Not for use in HVHZ Zones
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 20 R3 26G IfPBR 1 4 IS -
32Plvwood NonHVHZ-Sianed odf
Created by Independent Third Party: Yes
Go to Page = 0
04)Page 1/211140
contact us :: 2601 Blair Stone Road, Tallahassee 1132399 Phone: 850-487-1824
The State of Florida is an WEEO employer. Coovriaht 2007-2013 State of Florida :: Privacy Statement:: Accessibility Statement :: Refund statement
Under Florida law, email addresses are public records. It you do not want your e-mail address released In response to a pubfic.recerds request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275
(1), Florida Statutes, effective pointer 1, 2012, licensees licensed under chapter 455, F.S. must provide Me Department with an email address if they have one. The
emalis provided may be used for official cenlmunication with the licensee. However email addmses are public record. If you do not wish to supply a personal address,
please provide Me Department with an email address which can be made available to the public To determine If you are a licensee under chapter 455, F.S., please
tlick li I .
Product Approval Accepts:
0" rina & 9
•a' � a
f, securityiuhTRIG4
https://floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K`/p2fFrZeCS... 3/ 18/2019
rlorlda Building Code Online
M
Page 1 of 2
SEE=
W_.i
Vic- .
BCIS Home j topin { User 0.egktratlon FTsI¢LuErchary�tetsa�EactP call I Contaet Ha I KlS5ite Map I Wks I Search f
—I IFl—onda 11 ®®PP
Y :t Ij�l r Product Approval
UIAC�. V uSER: Public user ��'•••//��^�1\\��' .�r�Lr�/1//J�
Produtt Approval Menu > Product or AonlIt,xon Search> Application List > Application Detail
FL # FL16048-R6
Application Type Revision ST. LUCIE COUNTY BUILD112 G D ION
Code Version 2017 REVIEWED F,QR COMPLIANCE i Ail
Application Status
Comments
Archived
Product Manufacturer
CONCEAL'0WA9%iZ&Vbti ATTACHMENTS
ARETHE RESPONSIBILITY OFTHE
CONTRACTOR OR RECORD
Approved
PLANS AND PERMIT MUST BE
SITE OR NO INSPECTION(S) 1
Tri-Built Materials Group, LLC
PO Box 70
Rutherford, NJ 07070
(800) 516-1485
david.Nlz@tribuiltmg.com
Authorized Signature
David Ruiz THESE PLANS AND ALL PROPOSED WORK
tlavid.ruiz@tribuiltmg.com R QUIREDB FIELD
INCORRECTIONS THAT
Technical Representative
David Ruiz NECESSARY
WITH
COMP ALL APPLICABLE CODES.
Address/Phone/Email
250 Route 17 North
East Rutherford, NJ 07073
(201) 842-2449
david.rulz@tribuiltmateriaisgroup.com
Quality Assurance Representative
SCANNED
Address/Phone/Email
BY
St. Lucie County
Category
Roofing
Subcategory
Underlayments
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/18/2020
Validated By John W. Knezevich, PE
M Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL16048 R6 COT 2017 01 COI Nieminen odf
Standard
Year
ASTM D1970
2015
ASTM G155
2005
FM 4474
2011
FRSA/TRI April 2012 (04-12)
2012
UL 1897
2012
https:Hfloridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtFPmdYiND Wrwip... 3/18/2019
Florida Building Code Online
Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 09/25/2017
Date Validated 10/01/2017
Date Pending FBC Approval 10/03/2017
Date Approved 12/12/2017
Summary of Products
I
FL #
I Model, Number or Name
Description
16048.1
TRI-BUILT Roof Underlayments
Self -adhering, modified bitumen roof underlayments
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FLIB048 R6 If 2017 09 FINAL ER TRl-
Approved for use outside HVHZ: Yes
BUILT UNDERLAYMENTS FL16048-R6.odf
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-150
Created by Independent Third Party: Yes
Other: 1.) The design pressure noted herein pertains to use
Evaluation Reports
of foam -on tile systems overtop the self -adhering
FL16048 R6 AE 2017 09 FINAL ER TRI-
underlayment for one particular application. See ER Section
BUILT UNDERLAYMENTS FL16048-R6.Ddf
5.6.4 for details. 2.) Refer to ER Section 5 for other Limits of
Created by Independent Third Party: Yes
Use.
F-_- _ckl Haze
contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850 W87-1824
The State of Florida Is an ANEW employer. copyright 2007-2013 State of Florida.:: Privacy, Statement :: Arcessibllity statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address releases in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department with an email address if they have one. The
smalls provided may he used for official communication with the licensee. However email addresses are Public rewrd. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under chapter 455, F.S., please
click be .
product Approval Accepts:
® =®—
Credit Card
Safe
https:Hfloridabuilding.org/pr/pr_app_dtl.aspx?param=wGEV XQwtDgtFPmdYiND Wrwip... 3/18/2019