HomeMy WebLinkAboutEVALUATION REPORTCREEK
TECHNICAL SERVICES, LLC
EVALUATION REPORT
Manufacturer:
Manufacturing Location:
Quality Assurance:
SCOPE
Certificate of Authorization No. 29824
1752D Edinburgh Drive
Tampa, FL 33647
(813)480-3421
FLORIDA BUILDING CODE, 6Te EDITION.(2017)
OWENS CORNING ROOFING AND ASPHALT LLC
1 Owens Coming Parkway
Toledo, OH 43657
(800)438-7465 SCANNED
www.owenscoming.com BY
Brentwood, NH St. Lucie County
Houston, TX
UL LLC (QUA9625)
Category:
Roofing
Subcategory:
Underiayments
Code Sections:
1504.3.1, 1507.1.1
Properties:
Physical properties
REFERENCES
Enti
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (rST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (rST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
Report No.
NEI-039-02-01
NEI-042-02-01REV2
NEI-045-02-01
NEI-045-02-01
NEI-053-02-01
NEI-053-02-01
NEI-093-02.02
OCF-213-02-01
OCF-237-02-01
OCF-252-02-01
OCF-252-02-01
OCF-253-02-02
OCF-272-02-01
OCF-296-02-02
PRI Construction
Materials Technologies
(TST5878)
OCF-297-02-01.1
PRI Construction
Materials Technologies
(TST5878)
OCF-318-02-01
PRI Construction
Materials Technologies (TST5878)
OCF-320-02.01
PRI Construction
Materials Technologies (TST5878)
OCF-320-02-01
PRI Construction
Materials Technologies (TST5878)
OCF-321,02.01
PRI Construction
Materials Technologies (rST5878)
OCF-322-02-01
PRI Construction
Materials Technologies (rST5878)
OCF-355-02-01
'Determined to be equivalent to ASTM D 226-09, Type I
and it
Issued October 11. 2017
Standard
ASTM D 1970
ASTM D 1970
TAS 103
ASTM G 155
TAS 103
ASTM G 155
ASTM D. 1970
ASTM D 1623
UL 1897
ASTM D.4798
ASTM D 1970
ASTM D 1970
TAS 103
ICC-ES AC 188'
ICC-ES AC 48
ASTM D 1970
ASTM D 1970
TAS 103
ASTM G 155
ASTM D 1623
UL 1897
UL 1897
Year
2015
2015
1995
2005a
1995
2005a
2015
2009
2012
2001
2015
2015
1995
2012
2012
2015
2015
1995
2005a
2009
2012
2012
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREED{
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION AND LIMITS OF USE
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock@ Self -Sealing Ice & Water Barriers
- WeatherLock@ G- - --WeatherLock(D Gis-an- ASTM -D-1970 self-adhesive undedayment constructed from-SBS—
(Brentwood, NH) modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock@ G is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a
maximum 30 days.
WeatherLock® Mat
WeatherLock@ Mat is an ASTM D 1970 self-adhesive undedayment constructed from
(Brentwood, NH or
SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1-
Houston, T)Q
sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions
of 3-it x 66.7-11.
WeatherLock@ Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 30 days.
WeatherLock@ Metal
WeatherLock® Metal is an ASTM D 1970 self-adhesive undedayment constructed from
(Brentwood, NH)
SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock Metal is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 90 days.
WeatherLock@
WeatherLock@ Specialty Tile & Metal is an ASTM D 1970 self-adhesive undedayment
Specialty Tile & Metal
constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric.
(Brentwood, NH or
The product is supplied in 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-ft.
Houston, T7Q
WeatherLock@) Specialty Tile & Metal is permitted to be used as prescribed in FBC
Section 1507.1.1. WeatherLock@ Specialty Tile & Metal is permitted to be used with
adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160 (ICP
Adhesives and Sealants, Inc.) or TILE BONDT6" Roof Tile Adhesive (The Dow Chemical
Company). Exposure on the roof deck shall be limited to a maximum 90 days.
The maximum roof slope shall be 6:12 when used with day or concrete file installations
without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 files per stack.
Weatherl-ockO G (High
WeatherLock® G (High Tear) is a self -adhered, undedayment used as an alternative to
Tear)
ASTM D 226,Type I or Type II roofing felt and ASTM D 1970 self -adhering polymer
(Houston,
modified bitumen underlayment. The undedayment is composed of SBS modified
asphalt with a fiberglass mat internalreinforcementand is surfaced with granules. The
product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal
dimensions of 3-ft x 65-ft.
WeatherLock® G (High Tear) is permitted to be used as prescribed in FBC Section
1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be
limited to a maximum 30 days.
OCR14002.6a
This evaluation report is provided for State of Florid
Technical Services, LLC of any product changes or
This evaluation report does not express nor imply t
specifically addressed herein.
FL9777-R11
ict approval under Rule 61 G20-3. The manufacturer shall ni
assurance changes throughout the duration for which this re
5 installation, recommended use, or other product attributes
2 of
valid.
a not
REV - OWENS CORNING ROOFING AND ASPHALT LLC
11 i\ WeatherLock® Self -Sealing Ice & Water Barriers
TECHNICAL SERVICES, LLC
PRODUCT APPLICATION
Min. -Roof Slope: 2:12 in accordance with the FBC -
Application: Alt undedayments shall be installed in accordance with the FBC.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All
fasteners in the deck shall be checked forprotrusion and corrected prior to undedayment
application. Prior to beginning installation, the undedayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The undedayment shall be installed with the release backer removed and pressed finely
Into place to ensure complete contact with the deck. The undedayment shall be installed
with the roll length parallel to the eave, starting at thesave, and with minimum 3" side
laps and minimum.6" end laps staggered min. 6-ft.from preceding course. Additionally, if
applying WeatherLock® Specialty Tile & Metal, end laps shall be primed with ASTM D
41 primer or sealed with asphalt roof cement a.minimum of 3-4. inches across the width
of the lap.
It Is permissible to back nail the undedayment 12-inches on -center as needed (nails shall
be installed perpendicular to deck with the nail heads flush to the top surface of the
undedayment). Additionally, WeatherLock® Specialty Tile & Metal shall be back nailed
when installed on roof slopes greater than 3:12.
Min. Application 40°F; Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
WIND RESISTANCE
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9
Underlayment Svstem No.1 —WeatherLock SDecially Tile & Metal Only
Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24" o.c.
Undedayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with
manufacturer's installation instructions to the fastened deck and backnailed along the
selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through
optionally primed, 32ga. x 1-5/6-inch 0 Un caps spaced 12" o.c. The applied
undedayment shall be rolled with a minimum 751b steel roller immediately following
application.
Maximum Design -142.5 psf
Pressure:
OCR14002.8a FL9777-RI1 Page.3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
GENERAL LIMITATIONS
OWENS CORNING ROOFING AND ASPHALT LLC
WealherLockO Self -Sealing Ice & Water Barriers
--I) This evaluation report is not use in the-HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall be property ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed to shed water from the deck.
7) The underiayment may be used as described in other current FBC product approval documents.
8) Design wind load pressures shall be determined for components and cladding in accordance with FBC
1609,
9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures for a given undedayment shall meet or exceed the design wind loads
determined for the roof assembly.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code a Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
,1,,GNPYrrR
No 74021
9. STATE OF
p�sg,O; NA� %%
CERTIFICATION OF INDEPENDENCE
2017.10.1
09:06:29
-04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any. company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial Interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product
END OF REPORT
OCR14002.82
4 of
This evaluation report is provided for State of Florida product approval under Rule 61G20a. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.