HomeMy WebLinkAboutNOAMlA,MI•PAD
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES WER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
GAF FI L
1 Campus Drive
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www. mi amid adc. eov/economv
SCANNED
Parsippany, NJ 07054 CONCEALED FASTENERS OR ATTACHMENTS sv
ARETHE RESPONSIBILITY OF THE St. LucieCount�
SCOPE: COWRACTOR OR RECORD
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHD (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHD may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Timberline HD®, Timberline® Natural Shadow®, Timberline® American Harvest®, and
Fortitud6m Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall he considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building p� i I
THE�jS,g�(�PIANSAND ALL PROPOSED WORK
This NOA renews and revises NOA # 14-1022.20 and consists of pages 1 ttt�t[11RED BY TOFIEA INSPECTORS CORRECTIONS
OR E IONS The submitted documentation was reviewed by Alex Tigers MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
ST. LUCIE COUP
REVIEWED FOR
NOA No.: 16-0811.11
Expiration Date: 02/21/22
)N revaI Date: 02/09/17
Page I of 6
SITMADE
E OR NO INSPECTIONS) WI
I
L
ROOFING ASSEMBLY APPROVAL
4PAW&
Rmfiov
Sub-Cateeorv:
Asphalt Shingles
Materials:
Laminate
Deck Type:
Wood
SCOPE
This approves GAF Timberline HD®, Timberline® Natural Shadow®, Timberline American® Harvest' , and
FortitudeT"r Shingles as manufactured by GAF as described in this Notice of Acceptance.
PRODUCT DESCRIPTION
Product
Dimensions
Test
Product Description
Specifications
GAF Timberline HD®
13'/4'x 39 3/s"
TAS HO
Fiberglass reinforced heavy weight asphalt
Manufacturing
roof shingle, with a laminate profile
Locations #1, 2, 3, 4, 5, 6, 7
GAF Timberline Natural
13'/;x 39 3/e-
TAS 110
Fiberglass reinforced heavy weight asphalt
Shadow®
roof shingle, with a laminate profile
Manufacturing
Locations #1, 2, 3, 4, 5, 6, 7
GAF Timberline® American
13 V; x 39 3/s"
TAS 110
Fiberglass reinforced heavy weight asphalt
Harvest®
roof shingle, with a laminate profile
Manufacturing
Locations #2, 4, 5, 6
GAF Fortitude''"'
13 V; x 39 3/8-
TAS 110
Fiberglass reinforced heavy weight asphalt
Manufacturing
roof shingle, with a laminate profile
Location #4
MANUFACTURING LOCATION
1. Tampa, FL
2. Michigan City, IN
3. Baltimore, MD
4. Myerstown, PA
5. Ennis, TX
6. Tuscaloosa, AL
7. - Dallas, TX
NOA No.: 16-0811.11
Expiration Date: 02/21/22
Approval Date: 02/09/17
Page 2 of 6
EVIDENCE SUBMTITED
Underwriters Labomtories,LLC
ASTM D3462
4787344101
07/25/16
Underwriters Laboratories, Inc.
ASTM D3462
I ICA48924.
10/24/11
Underwriters Laboratories, Inc
ASTM D3462
IOCA21994
04/22/11
Underwriters Laboratories, Inc
ASTM D3462
1 OCA28717
07/26/11
Underwriters Laboratories, Inc.
ASTM D3462
05CA47541
11/10/06
Underwriters Laboratories, Inc.
ASTM D3462
06CA31580
11/30/06
PRI Asphalt Technologies, Inc.
ASTM D3462
GAF-101-02-02
11/02/05
Underwriters Laboratories, Inc.
ASTM D3462
06NK05159
08/09/06
PRI Asphalt Technologies, Inc.
ASTM D3462
GAF-098-02-02
11/08/05
Underwriters Laboratories, Inc.
ASTM D3462
02NK41809
08/11/02
Underwriters Laboratories, Inc.
ASTM D3462
03NK26444
10/17/03
Center for Applied Engineering
ASTM D3462
257989
05/13/97
Underwriters Laboratories, Inc.
TAS 107
OINK45803
04/13/94
Underwriters Laboratories, Inc.
TAS 107
06NK05159
08/09/06
Underwriters Laboratories, Inc.
TAS 107
04NK04273
02/20/04
Underwriters Laboratories, Inc.
TAS 107
05CA42840
11/11/05
Underwriters Laboratories, Inc.
TAS 107
02NK41811
11/11/02
Underwriters Laboratories, hic.
TAS 107
03CA35209
10/17/03
Underwriters Laboratories, Inc.
TAS 107
04CA13850
08/30/04
Center for Applied Engineering
TAS 100
257989
04/01/97
PRI Asphalt Technologies, Inc.
TAS 100
GAF-044-02-01
01/13/04
PRI Asphalt Technologies, Inc.
TAS 100
GAF-098-02-01
11/08/05
PRI Asphalt Technologies, Inc.
TAS 100
GAF-101-02-01
11/09/05
PRI Asphalt Technologies, Inc.
TAS 100
GAF-116-02-02
03/23/06
PRI Asphalt Technologies, Inc.
TAS-100
ELK-083-02-01
10/16/02
ELK 084-02-01
10/15/02
ELK-085-02-01
10/14/02
ELK-086-02-01
10/24/02
ELK-087-02-01
10/21/02
ELK-088-02-01
10/16/02
ELK-107-02-01
10/09/03
ELK-108-02-01
10/09/03
ELK-109-02-01
10/09/03
LIMITATIONS
1. Fire classification is not part of this acceptance, refer to a current Approved Roofmg Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 16-0811.11
MwnuDADECounm Expiration Date: 02/21/22
up Me
Approval Date: 02/09/17
Page 3 of 6
INSTALLATION
1: 4hinplre chill hn inetallrA in rmmvilianrn with Rnnfinp *nnliratirm 4tamfanl R*R 1lq-
2. Flashing shall be in accordance with Roofmg Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be -in compliance with Detail 'A', attached.
5. Nailing shall be in compliance with Detail B', attached.
LABELING
Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of
manufacturing facility, and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade
County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS
1. Application for bulding permit shall be accompanied by copies o_f the following.
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 16-0811.11
MLAM6® Nl"Y Expiration Date: 02/21/22
Approval Date: 02/09/17
Page 4 of 6
J
DETAIL A
COURSE LAYOUT
NOA No.: 16-0811.11
Expiration Date: 02/21/22
Approval Date: 02/09117
Page 5 of 6
DETAIZ B
OVERALL DIMENSIONS AND NAIIdNG PATTERN
39-31811
(tor)
1411/-17-1/se-al-1/2"--
(363-40.5mm
r1 1- 6-12"-9-12"
1)_ nss-a.ioaN nos-a,nmi
j33'hnm
e3-
ENHANCED NAILING PATTERN - six nails per shingle*
required. by some local codes and required for enhanced wind coverage on certain products.
See limited vmmardy for deWff&
These shingles MUST be nailed a nominal 6" (152mm) from bottom of
of shingle, above the cut outs, as shown. Nails must not be exposed.
END OF THIS ACCEPTANCE
Nail guide line
53W-6-1W
(146mm-159mm)
form bottom of shingle
adhesive
on back
NOA No.: 16-0811.11
Expiration Date: 02/21/22
Approval Date: 02/09/17
Page 6 of 6
MI® MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
SCANNED 11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BY Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION St. LOCI@ County T (786)31572590 F (786) 31525-99
NOTICE OF ACCEPTANCE (NOA) www.mlaaudade.cov/economy
20 Moo Teed Corporati T L E COPY
20 Moores Road 1
Malvern, PA 19355 -I
SCOPE: �, 12 b� ( -- :t ( f (9.3 —L Z fl° Q
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: CertainTeed Conventional Built -Up -Roof Systems over Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 16-0322.25 and consists of pages 1 through 22.
The submitted documentation was reviewed by Alex Tigera.
MIAMI•DADE COUNTY NOA No.: 17-1003.15
. • • •, , Expiration Date: 06/19/23
Approval Date: 04/26/18
Page 1 of 22
ROOFING SYSTEM APPROVAL
Cateeorv•
Roofing
Sub-Cateeorv:
Built -Up Roofing
_Material:
Fiberglass
Deck Type:
Wood
Maximum Desien Pressure:
-60 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Product
Black DiamondrM Base
Sheet
Flintlastic Ultra Glass SA
Flintglas Ply 4
Flintglas Premium Ply 6
Dimensions
36" x 687'; Roll
weight: 78 lbs.
(2 squares)
39 3/S" x 33' 11"
36" x 164'7';
Roll weight: 40/55 lbs.
(5 squares)
39 3/8" x 164'7"; Roll
weight: 40 lbs.
(5 squares)
Test
Specification
Product
Description
ASTM D 1970 Self -adhering fiberglass reinforced modified
bitumen base sheet
ASTM D 1970 Self -adhering, fiberglass reinforced, SBS
modified bitumen base/ply sheet.
ASTM D 2178 Fiberglass, asphalt impregnated ply sheet.
Type IV
UL Type G1
ASTM D 2178 Fiberglass, asphalt impregnated ply sheet.
Type VI
UL Type GI
Flintglas® MS Cap 36" X 32' 10'; ASTM D 3909 Asphalt impregnated and coated inorganic glass
CoolStar Roll Weight: 78 lbs. UL Type G3 fiber surfaced with mineral granules used as the
(1 square) top ply in conventional built-up roof membranes.
Covered with reflective CoolStar Coating.
Flintglas® MS Cap Sheet 36" X 32' 10' ASTM D 3909 Asphalt impregnated and coated inorganic glass
Roll Weight: 78 lbs. UL Type G3 fiber surfaced with mineral granules. used as the
(1 square) top ply in conventional built-up roof membranes.
Yosemite® Venting Base 39 3/8" x 32' 10" ASTM D 3909 Mineral surfaced fiberglass reinforced buffer
Sheet ASTM D 4897 sheet.
UL Type G3
Flintlastic Poly SMS Base 39 3/8" x 64'3" ASTM D 4601 SBS modified, polyester reinforced base/ply
Sheet Grade S sheet.
Type H
GlasbaseTM Base Sheet 36" x 98'9'; ASTM D 4601 Asphalt coated, fiberglass base sheet.
Roll weight: 69 lbs.
All Weather/Empire Base 36" x 65' 10'; ASTM D 4601 SBS modified, fiberglass reinforced base/ply
Sheet Roll weight: 86lbs. Type 11 sheet.
(2 squares)
MIAM6DADE COUNTY
NOA No.: 17-1003.15
ON-IT17m, Expiration Date: 06/19/23
Approval Date: 04/26/18
Page 2 of 22
Flexiglas Base Sheet
36" x 98'9";
Roll weight: 90 lbs.
(3 squares)
Flintlastic Base 20
36" x 98'9";
Roll weight: 90 lbs.
(3 squares)
Flintlastic Ultra Poly SMS
39 3/s" x 32' 10"
Base Sheet
APPROVED INSULATIONS:
Product Name
F1imBoard ISO
F1intBoardx ISO
ACFoam-II
H-Shield
DensDeck, DensDeck Prime
ENRGY 3, ENRGY 3 25 PSI
Ultra -Max, Multi -Max FA-3
ASTM D 4601
SBS modified, fiberglass reinforced base/ply
Type II
sheet.
ASTM D 6163
SBS modified, fiberglass reinforced base/ply
Grade S
sheet.
Type
ASTM D 6164
SBS modified, polyester reinforced base/ply
Grade S
sheet.
Type
TABLE 2
Product Description
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Water resistant gypsum board
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Structodek High Density Fiberboard Roof High Density Wood Fiber insulation
Insulation board.
EnergyGuardTM Perlite Roof Insulation
Fesco Board
Perlite insulation board
Expanded perlite and fiber insulation
Manufacturer
(With Current NOA)
CertainTeed Corp.
CertainTeed Corp.
Atlas Roofing Corporation
Hunter Panels, LLC
Georgia Pacific Gypsum LLC
Johns Manville Corp.
RMax Operating, LLC.
Blue Ridge Fiberboard, Inc.
GAF
Johns Manville Corp.
MIAMI•DADE COUNTY NOA No.: 17-1003.15
• • • � � Expiration Date: 06/19/23
Approval Date: 04/26/18
Page 3 of 22
APPROVED FASTENERS:
TABLE 3
Fastener
Product
Product
Manufacturer
Number
Name
Description
Dimensions
(With Current NOA)
1.
Dekfast DF-#14 PH3 &
Insulation fastener
SFS Group USA
Dekfast DF-#15 PH3
2.
Dekfast PLT-H-2-7/8
Galvalume AZ50 steel plate
2'/s" x 3 11/4"
SFS Group USA
3.
Dekfast PLT-P-R-3
Polypropylene plate
3" x 3 '/4"
SFS Group USA
4.
#12 Standard Roofgrip &
Insulation fastener for wood
OMG, Inc.
#14 Roofgrip
and steel.
5.
AccuTrac Hextra
Insulation fastener for wood
OMG, Inc.
and steel
6.
3 in. Ribbed Galvalume
Galvalume stress plate.
3" round
OMG, Inc.
Plate
7.
AccuTrac Plate
Galvalume stress plate.
3" square
OMG, Inc.
8.
3 in. Round Metal Plate
Galvalume AZ50 steel plate
3" round
OMG, Inc.
9.
Trufast #12 DP & Trufast
Insulation fastener for wood
Altenloh, Brinck & Co.
#14 HD Fastener
and steel decks
U.S., Inc.
10.
Trufast 3" Metal Insulation
Galvalume AZ50 steel plate
3" round
Altenloh, Brinck & Co.
Plate
U.S., Inc.
11.
F1intFast #12 & #14
Insulation fastener for wood
CertainTeed Corp.
and steel decks
MIAMI-DADE COUNTY
NOA No.: 17-1003.15
Expiration Date: 06/19/23
Approval Date: 04/26/18
Page 4 of 22
EVIDENCE SUBMITTED:
Test Aeencv/Identifier
Name
Reuort
Date
TrinitylERD
TAS 117 (B)
3503.10.06
10/10/06
TAS 117 (B)
06490.04.07-R1
06/27/07
TAS 117 (B)/ ASTM D6862
C8500SC.11.07
11/30/07
FM 4470 / TAS 114
C8370.08.08-R1
10/05/09
ASTM Physical Properties
C10080.09.08-R4
03/25/10
TAS 117 (B)
C35500.02.11
02/09/11
FM 4470 / TAS 114
3513.08.02 Rl
03/17/11
FM 4470 / TAS 114
03515.07.03-1-R1
06/27/12
ASTM D4601
C40050.09.12-1
09/28/12
ASTM D1970
C40050.09.12-2
09/28/12
ASTM D3909
C44200.03.13
03/22/13
ASTM D2178
C47250.03.14
03/26/14
ASTM D1876
C35460.05.11-R1
05/20/15
ASTM D3909
CTR-SC11145.09.16-2A
09/19/16
ASTM D3909
CTR-SC11145.09.16-213
09/19/16
ASTM D4601
CTR-SC11145.09.16-3A
09/19/16
ASTM D4897
CTR-SC11145.09.16-4
09/19/16
Factory Mutual Research Corp.
FMRC 4470
J.I. #3Y8A1.AM
03/23/96
FMRC 4454
J.I.OD3A3.AM
04/04/97
FMRC 4470
J.I. 1D7A4.AM
11/09/98
FMRC 4470
J.I.2DOAO.AM
12/23/98
Underwriters Laboratories, Inc.
UL 790
R11656
01/11/13
PRI Construction Materials
ASTM D6163
CTC-066-02-01
08/09/11
Technologies LLC
ASTM D2178
CTC-123-02-01
03/13/12
ASTM D4601
CTC-124-02-01
03/13/12
ASTM D4601
CTC-127-02-01
03/13/12
ASTM D6164
CTC-190-02-01
12/02/13
ASTM D1970
CTC-199-02-01
01/22/14
MU1Mb
NOA No.: 17-1003.15
97 6 COUNTY
• • • , , Expiration Date: 06/19/23
Approval Date: 04/26/18
Page 5 of 22
APPROVED ASSEMBLIES:
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood p/Base
System Type A(1): Anchor sheet mechanically fasteneulation adhered with approved asphalt.
All General and System Limitations apply.
Anchor sheet: All Wed er/Empire Base Sheet, Flt, Flintlastic Base 20, Flintlastic Poly
SMS Base heet,Flintlastic Ultra Pheet, Glasbase Base Sheet or Yosemite
Venting Base beet mechanically ad below.
Fastening: Anchor sheet shalkbe lapped 4" d fastened with approved roofing nails and tin caps 9" o.c. in
the lap and two ros staggere in the center of the sheet 12" o.c
One or more layers of any of the following
Insulation Laver
FlintBoardn ISO, ENRGY 3, Ultra -Max,
Minimum 1" thick /
Fesco Board or EnergyGuardrm
Minimum'/4" thick
Structodek High Density
Minimum %11 thick
DensDeck, Dens -Deck
Minimum''/4" thick
Roof Insulation
Roof Insulation
Insulation Fasteners Fastener
Table 3 Density/ft2
N/A N/A
N/A N/A
N/A N/A
N/A N/A
Note: All insulation shaWbe adhered to the anchor sheet in full mopping f approved hot asphalt within the
EVT range and at a rate of 20-40 lbs./100 W. Please refer to Roofmg App anon Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used
onl s base layers with a second layer
of approved top layer insulation installed as the final membrane substrate. C mposite insulation panels may be
used as a top layer placed with the polyisocyanurate side facing down.
Base Sheet: Install one ply of All Weather/Empire Base Sheet, Flexigla\Bas Sheet, Flintlastic Base 20,
(Optional) Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base\Sheet or Glasbase Base
Sheet directly over the top layer of insulation. Adhere with any approved mopping asphalt at
an application rate of 20-35 lbs./sq.
Ply Sheet: One ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20,
Rintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or two or more plies
of Flintglas Ply Sheet 4 or Flintglas Premium Ply 6 adhered in a full mopping of approved
asphalt at an application rate of 20-351bs./sq.
MIAMI•DADE COUNTY NOA No.: 17-1003.15
• •, , Expiration Date: 06/19/23
Approval Date: 04/26/18
Page 6 of 22
Cap Sheet: One ply of Flintglas MS Cap Sheet or Flintglas MS Cap Co Soar adhered in a full mopping of
(Optional) approved asphalt at an application rate of 20-35 lbs./sq.
Surfacing: (Required if no cap sheet is used) Any coating, lis below, used as a surfacing, must be listed
within a c ent NOA. Install one of the follow}
1. Grav or slag applied at 400 lb./sq. a d 3001b./sq. respectively in a flood coat of
approv asphalt at 60 lb./sq.
2. A two p coating consisting of ase coat of APOC #300 Non-Fibered Emulsion at
rate of 3 ga sq.; surfaced wi gal./sq. APOC#212 Fibered Aluminum Roof
Coating.
Maximum Design
Pressure: -45 psf (See General
NOA No.: 17-1003.15
Expiration Date: 06/19/23
Approval Date: 04/26/18
Page 7 of 22
Deck Type 1I:
Deck Description:
System Type A(2):
Wood, Insulated
19/32' or greater plywood or wood plank attached using approved nails spaced 6" o.c. at wood
joists spaced maximum 24" o. c
Anchor sheet mechanically fastened; all layers
All General and System Limitations apply.
Anchor sheet: All Weather/Empire Base Sheet, Flexiglas
Flintlastic Ultra Poly SMS Base Sheet, GI
Flintglas Premium Ply 6 mechanically atta
Fastening: Anch r sheet shall be lapped 4" and
tin ca 8" o.c. in the lap and three i
One or more layers of any of the f Mowing insulations. /
Insulation Laver
ENRGY 3, Multi -Max FA-3,
Minimum 1.5" thick
Fesco Board or EnergyGuardTM
Minimum 3/4" thick
Structodek High Density
Minimum'/:" thick
DensDeck, DensDeck
Minimum %11 thick
adhered with approved asphalt.
.Sheet, Flintlastic Poly SMS Base Sheet,
e Base Sheet, Yosemite Venting Base Sheet or
as detailed below.
ned with 11 ga. annular ring shank nails and approved
staggered in the center of the sheet 8" o.c.
xtion Fasteners Fastener Density/ftz
Table 3
•d ISO, F1intBoarda ISO, H-Shield
N/A N/A
N/A N/A
N/A
N/A \ N/A
Note: All insulations 11 be adhered to the anchor sheet in full opping of approved hot asphalt within the
EVT range and at a to of 2040 lbs./100 fe. Please refer to Roofihq Application Standard RAS 117 for
insulation attachm t. Insulation listed as base layer only shall be u d only as base layers with a second layer
of approved top I er insulation installed as the final membrane subst te. Composite insulation panels may
used as a top la er placed with the polyisocyanurate side facing down.
Base Sheet: Install one ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20,
(Optional) Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Glasbase Base
Sheet directly over the top layer of insulation. Adhere with any approved mopping asphalt at
an application rate of 2040 lbs./sq.
Ply Sheet: One ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20,
Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or two or more plies
of Flintglas Ply Sheet 4 or Flintglas Premium Ply 6 adhered in a full mopping of approved
asphalt at an application rate of 20-40 lbs./sq.
MIAM4DADE COUNTY
NOA No.: 17-1003.15
• • • , , Expiration Date: 06/19/23
Approval Date: 04/26/18
Page 8 of 22
Cap Sheet: One ply of Flintglas MS Cap Sheet or Flintglas MS Cap CoolStar adhered in a full mopping of
(Optional) approved asphalt at an application rate of 20-35 lbs./sq.
Surfacing: (Required if no cap sheet is used) Any coating, listed low, used as a surfacing, must be listed
within a current NOA. Install one of the following:
1. Gravel or slag applied at 400 lb./sq. and 3 0 lb./sq. respectively in a flood coat of
approved asphalt at 60 lb./sq.
2. Ntwo part coating consisting of a ba coat of APOC #300 Non-Fibered Emulsion at
rat of 3 gal./sq.; surfaced with 1 ./sq. AP0
C#212 Fibered Aluminum Roof
Maximum Design
Pressure:
-52.5 psf (See
MIAMI•DADE COUNTY NOA No.: 17-1003.15
. • • • 4 , Expiration Date: 06/19/23
Approval Date: 04/26/18
Page 9 of 22
Deck Type 11:
Deck Description:
Wood, Insulated
19/32" or greater plywood or wood plank attached using approved nails spaced 6" o.c. at wood
joists spaced maximum 24" o. c /I
System Type A(3): Anchor sheet mechanically fastened; all layers
All General and System Limitations apply.
Anchor sheet: All Weath mpire Base Sheet, Flexiglas
Flintlastic tra Poly SMS Base Sheet, GI
Flintglas Pre um Ply 6 mechanically atta
with approved asphalt.
Sheet, Flintlastic Poly SMS Base Sheet,
e Base Sheet, Yosemite Venting Base Sheet or
as detailed below.
Fastening: Anchor sheet sh 1 be lapped 4" and dstened with 11 ga, annular ring shank nails and approved
tin caps 8" o.c. ' the lap and thre ows staggered in the center of the sheet 8" o.c.
One or more layers of any of the following' ulations
Insulation Laver Insulation Fasteners Fastener
Table 3 Densit /fe
ENRGY 3, Multi -Max FA-3, ACFoam-II. yard ISO, FlintBoarda ISO, H.-Shield
Minimum 1.5" thick 7 N/A N/A
Note: All insulation shall be adhere to the anchor s eet in full mopping of approved hot asphalt within the
EVT range and at a rate of 20-401 s./100 ftZ. Please r er to Roofing Application Standard RAS 117 for
insulation attachment. Insulatio listed as base layer o y shall be used only as base layers with a second layer
of approved top layer insulatio installed as the final me bran substrate. Composite insulation panels may be
used as a top layer placed the polyisocyanurate side f ing down.
Base Sheet: O�(e ply of Black Diamond Base Sheet orViintlastic Ultra Glass SA self -adhered.
Ply Sheet: -/One ply of All Weather/Empire Base Sheet,)(lexiglas Base Sheet, Flintlastic Base 20,
Flintlastic Poly SMS Base Sheet, Flintlastic Poly SMS Base Sheet or two or more plies
of Flintglas Ply Sheet 4 or Flintglas Premium P_ 6 adhered in a full mopping of approved
asphalt at an application rate of 20-40 lbs./sq.
Cap Sheet: One ply of Flintglas MS Cap Sheet or Flintglas MS Iap CoolStar adhered in a full mopping of
(Optional) approved asphalt at an application rate of 2040 lbs./s
Surfacing: (Required if no cap sheet is used) Any coating, listed below, used as a surfacing, must be listed
within a current NOA. Install one of the following:
1. Gravel or slag applied at 4001b./sq. and 300 lb./sq. respectively in a flood coat of
approved asphalt at 60 lb./sq.
2. A two part coating consisting of a base coat of APOC #300 Non-Fibered Emulsion at
rate of 3 gal./sq.; surfaced with 1 gal./sq. APOC#212 Fibered Aluminum Roof
Coating.
Maximum Design
Pressure:
-52.5 psf (See General Limitation #7)
MU1MI•DADE COUNTY
NOA No.: 17-1003.15
. • • • , , Expiration Date: 06/19/23
Approval Date: 04/26/18
Page 10 of 22
i1
Deck Type 1I:
Deck Description:
System Type A(4):
Wood, Insulated
19/32 " or greater plywood or wood plank attached using approved nails spaced 4" o.c. at
wood joists spaced maximum 24" o. c.
Anchor sheet mechanically fastened; all layers of insulation ,adhered with approved asphalt.
All General and System Limitations apply.
Anchor Sheet All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet,
(\ Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet, Yosemite Venting Base Sheet
r Flintglas Premium Ply 6 mechanically a�dched as detailed below.
Fastening:
One or more layers of any of the
Insulation Laver
ENRGY 3, Multi -Max FA-3,
Minimum 1.5" thick
Fesco Board or EnergyGuardTM
Minimum'/a" thick ,
Structodek High Density
Minimum''/:" thick
DensDeck, Di
Minimum'/a"
sheet shall be lapped 4" and q&tcned with 11 ga. annular ring shank nails and
d tin caps 8" o.c. in the lap/dnd three rows staggered in the center of the sheet 8"
Roof Insulation
Insulation Fasteners Fastener
able 3 Density/ftz
ISO, FlintBoardn ISO, H-Shield
N/A N/A
N/A N/A
N/A N/A
N/A N/A
Note: All insulation shall be adhered to the anchor sheet in fu
opping of approved hot asphalt within the
EVT range and at a rate of 20-40 lbs./100 ft'. Please refer to Ro mg Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be sed only as base layers with a second layer
of approved top layer insulation installed as the final membrane su trate. Composite insulation panels may be
used as a top layer placed with the polyisocyanurate side facing down:,
Base Sheet: Install one ply of All Weather/Empire, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic
(Optional) Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Glasbase Base Sheet
directly over the top layer of insulation. Adhere with any approved mopping asphalt at an
application rate of 2040 lbs./sq.
Ply Sheet: One ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20,
Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or two or more
plies of Flintglas Ply Sheet 4 or Flintglas Premium Ply 6 adhered in a full mopping of
approved asphalt at an application rate of 20.40 lbs./sq.
NOA No.: 17-1003.15
Expiration Date: 06/19/23
Approval Date: 04/26/18
Page 11 of 22
Cap Sheet: One ply of Flintglas MS Cap Sheet or Flintglas MS Cap CoolStar adhered in a full mopping of
(Optional) approved asphalt at an application rate of 20-40 lbs./sq.
Surfacing: (Required if n cap sheet is used) Any coating, listed below, usedfac a surfacing, must be listed
within a cur{en OA. hvstall one of the following:
1. Gravel o lag applied at 400 lb./sq. and 300 lb./s . respectively in a flood coat of
approved a halt at 60 lb./sq.
2. A two partc ating consisting of a base coa f APOC #300 Non-Fibered Emulsion at
rate of 3 gal./ .; surfaced with 1 galds APOC#212 Fibered Aluminum Roof
Coating.
Maximum Design
Pressure: -60 psf(See General
NOA No.: 17-1003.15
Expiration Date: 06/19/23
Approval Date: 04/26/18
Page 12 of 22
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank.
System Type B: Base layer of insulation mechanically fastened, optional top layer adhered with approved
asphalt.
All General and System Limitations apply. /
One or more layers of any
Base Insulation Laver
ACFoam-H, FlintBoard ISO
Minimum 1.3" thick
ENRGY 3, H-Shield, FlintBoarda ISO
Minimum 1.4" thick
Ultra -Max
Minimum 1.5" thick
Fesco Board or EnergyGuardTM
Minimum %11 thick
Structodek High Density
Minimum''%11 thick
Note: Base layer shall be
listed are minimum sizes
increased maintaining tq
details). 7
insulations.
Roof Insulation
Roof Insulation
ichanically attached with fasteners and
d dimensions; if larger panels are used
same fastener density (See Roofing Appl
Any of the insulations listed for Base Layer, above.
Insulation Fasteners
able 3
1,4,5
1,4,5,9or11
1,4,5,9or11
1,4,5,9or11
1,4,5,9or11
Fastener
Density/ft2
1:3 ft2
1:3 ft2
1:2.9 ft2
1:2 ft2
1:2 ft2
described above. Insulation panels
aber of fasteners per board shall be
Standard RAS 117 for fastening
Won Fasteners Fastener
able 3 Densitv/ft2
Note: Optional top layer of insulation shall be adhered with approved asphalt within the EVT range and at a
rate of 20-40 lbs./100 W. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Composite insulation boards used as a top layer shall be installed with the polyisocyanurate face down.
Base Sheet: Install one ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20,
(Optional) Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Glasbase Base
Sheet directly over the top layer of insulation. Adhere with any approved mopping asphalt at
an application rate of 20-35 lbs./sq.
MIAMI•DADE COUNTY
NOA No.: 17-1003.15
. • • •, , Expiration Date: 06l19/23
Approval Date: 04/26/18
Page 13 of 22
Ply Sheet:
One ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20,
Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Pol MS Base Sheet or two or more plies
of Flintglas Ply Sheet 4 or Flintglas Premium Ply 6 ered in a full mopping of approved
as at an application rate of 20-351bs./sq.
Cap Sheet:
'One iid�ly of Flintglas MS Cap Sheet or Flintgl MS Cap CoolStar adhered in a full mopping of
(Optional)
t an application rate of 2 -35 lbs./sq.
approveXio
Surfacing:
(Requiresheet is used) AnyyMing, listed below, used as a surfacing, must be listed
within aOA. Install one ofthe following:
1. slag applied lb./sq. and 300 lb./sq. respectively in a flood coat of
%40
sphalt at 60, b./sq.
2. coating onsisting of a base coat of APOC #300 Non-Fibered Emulsion at
a /sq.- surfaced with 1 gal./sq. APOC#212 Fibered Aluminum Roof
Coating.
Maximum Design
Pressure:
A5 psf (See
a
MIAMI-DADE COUNTY
NOA No.: 17-1003.15
Expiration Date: 06/19/23
Approval Date: 04/26/18
Page 14 of 22
Deck Type 1I:
Deck Description:
System Type C:
All General and
One or more layers
ACFoam II, ENRGY 3,
Minimum 1" thick
Wood, Insulated
19/32 " or greater plywood or wood plank.
All layers of insulation simultaneously attached.
Limitations apply.
of the following insulations.
Fesco Board or EnergyGuardTM
Minimum %11 thick
FlintBoard ISO,
Structodek High Density Fiberboard
Minimum13/:" thick /
Note: All layers shall be
Too Insulation Laver
ACFoam-II, FlintB rd ISO
Minimum 1.3" thA
FlintBoardn o, ENRGY 3, H-Shield
Minimuml/4" thick
Ultra -Max
Minimum 1.5" thick
Roof
Insulation Fasteners
able 3
ISO, H-Shield
N/A
N/A
N/A
see top layer below for fasteners and density.
Insulation Fasteners
able 3
1,4,5
1,4,5,9or11
1,4,5,9or11
Fesco Board or EnergyGuardTM Perlite Roof Insulation
Minimum'/V thick 1, 4,9 or 11
Structodek High Density Fiberboard Roof Insulation
Minimum %" thick 1, 4, 5, 9 or 11
Fastener
Density/ft2
N/A
N/A
N/A
Fastener
Density/ft2
1:3 W
1:3 ftz
1:2.9 W
1:2 ftz
1:2 W
Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The
insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners
shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117
for insulation attachment.
Base Sheet: Install one ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20,
(Optional) Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Glasbase Base
Sheet directly over the top layer of insulation. Adhere with any approved mopping asphalt at
an application rate of 20-40 lbs./sq.
NOA No.: 17-1003.15
Expiration Date: 06/19/23
Approval Date: 04/26/18
Page 15 of 22
r—�
Ply Sheet: One ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20,
Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or two or more plies
of Flintglas Ply Sheet 4 or Flintglas Premium Ply 6 adhered in a full mopping of approved
asphalt at an application rate of 20-40 lbs./sq.
_ Cap Sheet:
(Optional)
Surfacing:
Maximum Design
Pressure:
One ply of Flintglas MS Cap Sheet or Flintglas MS Cap CoolStar adhered in a full mopping of
approv-d asphalt at an application rate of 2040 lbs./sq:
Required ifTo cap sheet is used) Any coating, listed
within a curr!pt NOA. Install one of the following:
1. Gravel slag applied at 400 lb./sq. and 300
approve asphalt at 60 lb./sq.
as a surfacing, must be listed
respectively in a flood coat of
2. A two p coating consisting of a base c t of APOC #300 Non-Fibered Emulsion at
rate of 3 g I./sq.; surfaced with 1 gal./s . APOC#212 Fibered Aluminum Roof
Coating.
45 psf (See General
NOA No.: 17-1003.15
Expiration Date: 06/19/23
Approval Date: 04/26/18
Page 16 of 22
Deck Type 1I:
Deck Description:
System Type D:
Wood, Insulated
19/32" or greater plywood or wood plank.
All layers of insulation and base sheet simultaneously attached.
All General and System Limitations apply.
One or more layers of any %theollowing insulations.
Base Insulation La er O Insulation Fasteners Fastener
able 3 Density/ft2
ACFoam-H, ENRGY 3, ENRGY 5 PSI, FlintBoard ISO, tBoardn ISO, H-Shield
Minimum 1.5" thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ftz
Fesco Board or EnergyGuardTM Perlite R f Ins ation
Minimum'/" thick N/A N/A
Structodek High Density Fiberboard Roof Ins ation
Minimum %" thick N/A N/A
DensDeck, DensDeck Prime
Minimum W' thick N/A N/A
Note: All insulation shall have ¢reliminary attachment, rior to the installation of the roofing membrane at a
minimum applicatio%Venting
o fasteners per board for ' sulation boards having no dimension greater than 4
ft., and four fastenesulation board having no ' ension greater than 8 ft.
Base Sheet: er/Empire Base Sheet, Flexigla Base Sheet, Flintlastic Base 20, Flintlastic Poly
e Sheet, Flintlastic Ultra Poly S Base Sheet, Glasbase Base Sheet or Yosemite
ase Sheet mechanically attached a etailed below.
Fastening: OMG #12 Standard Roofgrip or #14 Roofgrip fa eners with OMG 3 in. Round Metal Plates,
Dekfast DF-#14 PH3 or Dekfast DF-415 PH3 with ekfast PLT-H-2-7/8 Plates, Trufast #12
DP or Trufast #14 HD Fasteners with Trufast 3" Mell Insulation Plates or FlintFast #12 &
#14 Fasteners with F1intFasf 3" Insulation Plates spaced 4" o.c. at a 4" side lap and two
staggered rows in the center of the sheet, 24" o.c.
Ply Sheet: One ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20,
Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or two or more plies
of Flintglas Ply Sheet 4 or Flintglas Premium Ply 6 adhered in a full mopping of approved
asphalt at an application rate of 20-35 lbs./sq.
Cap Sheet: One ply of Flintglas MS Cap Sheet or Flintglas MS Cap CoolStar adhered in a full mopping of
(Optional) approved asphalt at an application rate of 20-35 lbs./sq.
MIAMI•DADE COUNTY
NOA No.: 17-1003.15
• • • i , Expiration Date: 06/19/23
Approval Date: 04/26/18
Page 17 of 22
Surfacing: (Required if no cap sheet is used) Any coating, listed
within a current NOA. Install one of the following:
1. Gravel or slag applied at 400 lb./sq. and 300
approved asphalt at 60 lb./sq.
2. A two part coating consisting of a base co
rate of 3 gal./sq.; surfaced with 1 gal./sq
Coating.
Maximum Design
Pressure: 45 psf (§ee General Limitation #9)
as a surfacing, must be listed
respectively in a flood coat of
APOC #300 Non-Fibered Emulsion at
#212 Fibered Aluminum Roof
NOA No.: 17-1003.15
Expiration Date: 06/19/23
Approval Date: 04/26/18
Page 18 of 22
Deck Type 11- Wood, Non -Insulated
Deck Descripti n: 19/32" or greater plywood or wood plank.
System Type E ): Base sheet mechanically attached.
All General and
Base Sheet: All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly
SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet, Yosemite
Venting Base Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below.
Fastening: Base sheet shall be lapped 4" and fastened with approved roofing nails and tin caps 9" o.c. in
the lap and two rows staggered in the center of the sheet 12" o.c.
Ply Sheet: One ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20,
Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or two or more plies
of Flintglas Ply Sheet 4 or Flintglas Premium Ply 6 adhered in a full mopping of approved
asphalt at an application rate of 20-35 lbs./sq.
Cap Sheet: One ply of Flintglas MS Cap Sheet or Flintglas MS Cap CoolStar adhered in a full mopping of
(Optional) approved asphalt at an application rate of 20-35 lbs./sq.
Surfacing: (Required if no cap sheet is used) Any coating, listed below, used as a surfacing, must be listed
within a current NOA. Install one of the following:
1. Gravel or slag applied at 400 lb./sq. and 300 lb./sq. respectively in a flood coat of
approved asphalt at 60 lb./sq.
2. A two part coating consisting of a base coat of APOC #300 Non-Fibered Emulsion at
rate of 3 gal./sq.; surfaced with 1 gal./sq. APOC#212 Fibered Aluminum Roof
Coating.
Maximum Design
Pressure: -45 psf (See General Limitation #9)
MIAMIDADE COUNTY NOA No.: 17-1003.15
. • • • , , Expiration Date: 06/19/23
Approval Date: 04/26/18
Page 19 of 22
Deck Type 1I: Wood, Non -Insulated
Deck Description: 19/32" or greater plywood or wood plank attached using a roved nails spaced 6" o.c. at wood
joists spaced maximum 24" o. c.
System Type E(2): Base sheet mechanically attached.
All General and System Limitations apply.
Base Sheet: All Weather/Empire Base Sheet, Flexiglas Bs&e Sheet, Flintlastic Poly SMS Base Sheet;
Flintlastic Ultra Poly SMS Base Sheet, G sbase Base Sheet, Yosemite Venting Base Sheet or
Flintglas Pr into Ply mechanically a ched as detailed below
Fastening: Base sheet shall a lapped 4" and fas ned with 11 ga. annular ring shank nails and approved
tin caps 8" o.c. in a lap and three ows staggered in the center of the sheet 8" o.c
Ply Sheet: One ply of All Weath mpire ase Sheet, Flexiglas Base Sheet, Flintlastic Base 20,
Flintlastic Poly SMS B Sh t, Flintlastic Ultra Poly SMS Base Sheet or two or more plies
of Flintglas Ply Sheet 4 or ' tglas Premium Ply 6 adhered in a full mopping of approved
asphalt at an application e f 20-351bs./sq.
Cap Sheet: One ply of Flintglas M Cap Sh t or Flintglas MS Cap CoolStar adhered in a full mopping of
(Optional) approved asphalt at application to of 20-35 lbs./sq.
Surfacing: (Required if no ca sheet is used) Any ating, listed below, used as a surfacing, must be listed
within a current OA. Install one of the lowing:
1. Grave or slag applied at 400 lb./sq. d 300 lb./sq. respectively in a flood coat of
appr ved asphalt at 60 lb./sq.
2. A o part coating consisting of abase c at of APOC #300 Non-Fibered Emulsion at
to of 3 gal./sq.; surfaced with 1 gal./sq. OC#212 Fibered Aluminum Roof
oating.
Maximum Design
Pressure: -52.5 psf (See General Limitation #7)
MIAMI•DADE COUNTY
NOA No.: 17-1003.15
• • • , , Expiration Date: 06/19/23
Approval Date: 04/26/18
Page 20 of 22
Deck Type 1I: Wood, Non -Insulated
Deck Description: "/32" or greater plywood or wood plank attached using
joists spaced maximum 24" o. c.
System Type E(3): Base sheet mechanically attached.
All General and System Limitations appl .
Base Sheet: All WeatherMmpire Bas Sheet, Flexiglas
Flintlastic Ultra Poly SMS ase Sheet, Gh
Flintglas Premium Ply 6 mec anically aZ
Fastening:
Ply Sheet:
Cap Sheet:
(Optional)
Surfacing:
Maximum Design
Pressure:
nails spaced 4" o.c. at wood
Sheet, Flintlastic Poly SMS Base Sheet,
Base Sheet, Yosemite Venting Base Sheet or
as detailed below
Base sheet shall be lapped 4" aft4 fa Yened with 11 ga. annular ring shank nails and approved
tin caps 8" o.c. in the lap and thre ows staggered in the center of the sheet 8" o.c
One ply of All Weather/Empir a Sheet, Flexiglas Base Sheet, Flintlastic Base 20,
Flintlastic Poly SMS Base S et, F1' lastic Ultra Poly SMS Base Sheet or two or more plies of
Flintglas Ply Sheet 4 or F1' glas Pre Ply 6 adhered in a full mopping of approved asphalt
at an application rate of 40 lbs./sq.
One ply of Flintglas Cap Sheet or Flint as MS Cap CoolStar adhered in a full mopping of
approved asphalt at application rate of 20 0 lbs./sq.
(Required if noyfip sheet is used) Any coating, l tec
within a curr54t NOA. Install one of the followinki
1. Gr el or slag applied at 400 lb./sq. and 30
approved asphalt at 60 lb./sq.
2. A two part coating consisting of a base coat
rate of 3 gal./sq.; surfaced with 1 gal./sq. AI
Coating.
-60 psf (See General Limitation #7)
below, used as a surfacing, must be listed
lb./sq. respectively in a flood coat of
#300 Nan-Fibered Emulsion at
Fibered Aluminum Roof
MIAMI•DADE COUNTY NOA No.: 17-1003.15
Expiration Date: 06/19/23
Approval Date: 04/26/18
Page 21 of 22
WOOD DECK SYSTEM LIMITATIONS:
1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the
EVT range and at a rate of 2040 lbs./sq., or mechanically attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size
shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot
mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at
each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the
strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt
application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be
limited to a maximum design pressure of 45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as
tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below
275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the
fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing,
prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof
Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken
from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard
RAS 117.
7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing
Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional
Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred
within this NOA, General Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to
Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones (i.e. perimeters, extended comers and comers). (When this limitation is specifically
referred within this NOA, General Limitation #7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 17-1003.15
MIAMI•DADE COUNTY Expiration Date: 06/19/23
Approval Date: 04/26/18
Page 22 of 22