HomeMy WebLinkAboutSLC FIRE PLAN REVIEWSAINT LUCIE,COUNTY FIRE DISTRICT �FCpdMT'`� PLAN REVIEW FORM l S160 N.W. Milner Drive Port Saint Lucie, FL 34983 Telephone: 772-621-3322 Fax: 772-621-3604 Web Address: www.slcfd.com SCANNED BY St. Lucie County Building Dept. ISLC FMO Permit# Project Name DVBI Amazon Delivery Center SLOG Permit If Address 17440 Commercial Circle City IFt Pierce B-19-100 1902-0594 Contractor Bryan Builders. Address 7440 Commercial Circle City Ft Pierce State FL Zip 34951 Telephone (800)336-3115 Architect/Engineer Progressive Architecture Telephone (616)361-1493 Occupancy Type Industrial Construction Type 116 Square Feet. 60,42E Occupant. Load 345 per plans Number of Stories I Access Box Required Access Key Switch AFS Permit Required FA Permit Required FFPPermit General Notes 1..An electronic copy of the construction documents submitted on a CD Is required. The file format shall be .pdf only. 2. All revisions, including the electronic copy must be received prior to permitting. 3. The Fire Marshal requires 24 hour notice on all inspections. 4. The respective Building Department shall schedule all final Inspections through the Fire Marshal's Office. S. Failed inspections require payment of fee prior to rescheduling of further inspections. 6. Penetrations through rated assemblies shall be of the proper UL design. Design criteria shall be submitted with the construction plans. 7. Fire alarm panels shall be located indoors within air conditioned space. 8. Plans and construction are subject to corrections in the field to maintain code compliance. 9. Automatic fan shutdown Is required for HVAC system/s that exceed 2,000 cfm design capacity. 10. The, Installation or Alteration of Fire Sprinklers, Fire Alarms, and Fixed Fire Protection Systems require a separate review and permit. THE FLORIDA FIRE PREVENTION CODE, 2015 EDITION IS CURRENTLY ENFORCED. BUILDINGS WITH LIGHT-FRAMESRUSS-TYPE CONSTRUCTION SHALL BE MARKED WITH APPROVED FIREFIGHTER SAFETY WARNING SIGNS IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODES 69A-3.012 AND 69A-60.0081 PRIOR TO RECEIVING A CERTIFICATE OF OCCUPANCY. See General Notes Above and Required Revisions Below 1. Automatic fan shutdown is required for HVAC system/s that exceed 2,000 cfm design capacity. Provide a remote test and inspect appliance equipped with an audible/visual indicator for each HVAC duct smoke detector. HVAC duct smoke detector(s) shall be tied into the fire alarm system. 2. The Installation or Alteration of Fire Sprinkler, Fire Alarm Systems require a separate review and permit. Page of I1 Reviewed by TonyJerger Date 03-21-2019