Loading...
HomeMy WebLinkAboutSCREEN ENCLOSURE PAPERWORKSN.10W FILE COPY 10 McAvO 60P Pr?. lTo3 - 030 PxLr4cy, FL7 �r = IS?) G j REVIEWED FOR CODE' COMPLIANCE ST. LUCIECOUNTY BOCC (RESsuENU) �'SnSTRJC.TURA4 IA2 �. MANSA FooF 2A3 0 _ I Lf v o� o0 00 .g � Zff �12rf / ax3 OEM rAA F -- 29'6n R M I i SCANNED St. Lucie County DO YEC>N KIM, P.E. FLA. LIC. NUMBER 49497 C^. # 20887 DO KIM S AS , LLC P_O. BO 00 9 TAMP^, F 79 (813) 87 �y.22•r9 CORNE.POST% EAVE RAIL __- :--- �M� _— BEAM STITCHING SCREVS (SEE TABLE) B 21. „✓� (11 TOTAL) - B12 x �V; SRS AS SHOWN Of' MIN _ S-V� SPLICE A PLATE (EACH SIDE OF BEAM) PATIO SECTION PLATE EDGE DISTANCE 6 SPACE SCREWS A q 5052-H32 ALLOY OR EQUAL, 1/8' THICKNESS _ r C-C FASTENER SPACING) EQUALLY (TYP.) COLUMN' ` F� J` O O O O 6' x 5' x 6063-T6 ALLOYLOY PLATE (ONE SIDE) OR STRONGER ., •,j,,' A ,'6 a K-BRACE OSJ�'•�9, __ _ _ 1 _� _ _ —❑__ ___ 3' x 3' x 0.050' MIN. 6063-T6 ALLOY 2x3xDG7D CHAIR RAIL PLATE OR STRONGER MINE SIDE) WITH (3) - M12 %' SM.S EACH SIDE AS x SHOWN (V MIN. PLATE EDGE DISTANCE K-BRACE 6 C-C FASTENER,SPACINW ® ® 0 n { ((tP0 N14x%' SCREWS K-BRACE ® � (MMv) CORNER POST ®B ® '� 0 6" ] BEAM LINE LINE SCREWS 'A' 'B'6'C' PLATE (1f,I/c �.OKLR 1{.5)1 TOTAL WIDTH 3' x 2' x OD50- MIN. 5063-T6 ALLOY PLATE OR STRONGER �\ (\MPO \4.xjI4P )}L FOB 1' 2%4 3 2 24 12' (ME SIDE)' B q` Z4 Y4F' l gµG 0" SO 2x5 3 3 32 14' (3) - p12 x S.M.S, K-HRRCE m♦\4%ice f� sc5! yy�_f(J\.xY ff 2x6 4 3 40 14- EACH SIDE AS SHOWN \, \1 ', 2x7 5 4 56 ,( 16' Y (Ya' MIN.1 PLATE EDGE GIRT (CHAIR RAID B \ VNE� l DISTANCE 6 C-C \'(` ;2x8 �5" 5 FASTENER SPACING) 2x2xa.093 �.� p,gSE _ , 2x9 `5 6 72 � P-l8' O BFACECFYP). MANSARD BEAM 2x9(HW) 6 7 88 18- O O OLE PLATE UNLESS OTHERWISE '\` CONNECTION DETAIL _ 2z10 _7 -. rT 96 l8' LIN CONCRETE ANCHOR PLACES) LIEUOFTYP. Ye CONCRETE II SCREWS COLUMN LATERAL"K" - BRACING FILE COPY CONNECTION DETAILS !,(5) P12x3/4- S.M.S. lx5x)§' ANGLE 6• LONG iX2 O.B. ATTACHED TO'BEPM W/ (TYP. B EACH BEAM) - (2)-iHOX2' S.M.SaMO SCREW BOSS (1)-1/4-4-B.S. THRU-BOLT (2) Y.'0%3' LG. R EACH ANGLE W/ Y• NUT AND WASHER NOTES PRIM O EACH SIDE OF BEAM ATTACHED j' CONVENTIC 2x7 S.M.S. O 24 D.C. FACIA TO HE 2x6 (MIN.) S.P.F. OVERHANG NO TO Ex( 2ad0.B. TO SUPER CUTTER OR WESTER RED CEDAR NOTED ON PLAN ➢VG. r STRUCTURAL GRADE 2 MIN. /12x3/4' S.M.S. (1) Y'0x2- -G. LAG SCREW 8 24' O.C. ENTIRE LENGTH OF GUTTER BEAM SECURE FASCIA TO EACH RAFTER TAIL OR SLOPED) V/ (1) Y'Ox4' LONG PAN HEAD LAG SCREWS }� BEFORE ATTACHING SUPER GUTTER (1) Y'Ox2' LE LAG SCREWS C❑ F� \ (TYP. 2 EACH BEAM) 1\ / (1) Y12x2' S.RS 2 12' o.c. (MAX) BETVEEN BEAMS EACH LED. YC THICK CONTINUOUS 5' 0 7- SUPER GUTTER /AANGLE MIN. 0.090- THICK // JIOxJ/4' S.M.S. L-Y' CONTINUOUS BEAD OF O 2' O.C. ADHESIVE x SEE FOR 9 FRAMING WITH MAX UNLESS OTHERWISE REVIEWED FOR SIZE CODE COMPLIANCE ST. •LUCIE COUNTY BOCC 1.14' BY 2' LONG ANGLE, EACH S10E (4) A14xX(' S.M.S.. 2 SCREWS EACH LEG (TYP) HOLLOW POST (2) BI0i4- S.M.S. THRU. A EAVE RAILINTO PURUN SCF BOSSES •�T �j' .1(r USE 11Oxt$`. S.M.KO 24' TO CONNECT,T0'1.2 O.B. 1 lag O.B. FAS)ENED TO W/(2) 810x1y' S.M.S. INTO TO EACH RAFTER TAIL MIN. (4) #IOx2' LONG S.M.S. INTO SCREW BOSSES (TYP. ALTERNATNE) LM.B. POST CHAIR RAIL / GIRT TO POST CONNECTION DETAIL d PURUN FASTENED TO COLUMN/POST WITH (4) e12x1' S.M.S. (EACH LED) USING M' THICK FLAT BAR BENT TO Fir (6063-T6 ALLOY) CONNECTION DETAIL DO KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL _ .ENGINEERS PO Box 10039 Tampa, FL 33679 Tel: (813) 374-0321 ISSUED (3) 112x$• S.M.S., EACH 1EG AND MN. (4) B10r3- LONG S.M.S. INTO %) 812A' S.M.S. CHANNEL TO BEAM SCREW BOSSES (iYP. ALTERNATNE) (9) SCREW TOTAL BEAM STRCHINC o TOM O.C. (TYP. TOP ANO BOTTOM OF SMB ...I 2x3r0.OJ0._ SEE TABLE FOR SIZES) �" ♦ eRAx (MIN. TO S.M.S. O 24' O.C. - TO 1x2 O.B. TO 20. EACH SIDE COLUMN TO PURUN��� tl = LU -' w c � UJ O U) \� 1x1xY' BY 3' LONG V 0 P RELIEVING CHANNEL ANGLE, EACH SIOE (TYP.) [_ O MATERIAL THICKNESS) p) " ) LED (fi) TOTAL (TYP.) U LU Cn U.I I—zW4 8) LU C Z of 4 O_ U a F PURLIN TO ROOF BEAM CONNECTION DETAIL Z V U Lu rn a U O DRAWN BY: DYK CHECKED BY. DYK uY. 1 S.M.B. BEAM SCALE: AS SHOWN MAY BE SLOPED OR MT DATE: _-_ (SEE PVVI FOR SIZE) Sepllpj/ < BY y� St. Lucie County 3 Y' MAX C-C OF FASTENERS (TYPJ MAIN POST / COLUMN TO ROOF BEAM CONNECTION DETAIL DO YEON KIM, P.E. FLA. REG. NUMBER 49497 00 KIM 1.6887 S, LLC C 26887 Box 10039 a, 679 ZZ •/ R Drawing No. -060811 SHEET 1OF3 PURUN SUPPORT ' 1"COLUMN/POST _ )§ ANGLE, EACH SIDE (W.) ��§'0 / Lw/B' x 2' 1G. ANGLE S.M.S. WIOI MIN. j§' CONCRETE ANCHOR W/ (4) I12x3/4• S.M.S EOCE DISTANCE W/2%m EMBEDMENT INTO (1 1.► (EACH SIDE) STRUCTURAL CONCRETE -] ft O O fa-0 CONCRETE ANCHOR — /^MEE NOTE, ,10) 1'0P'O.B. SOLE PLATE O O W/2)6• EMBEDMENT INTO 1rJ - 24 PURUN _ /_ STRUCTURAL CONCRETE (EACH SIDE) m3 ••. •'.. - _ _ •4. .+ ..y*,, .5 .' _ - 2xidfi• ANGLE CUP. CUT AT •, AQ A ANGLE AND /////• 3'/MIN/'(TYR) ' BEAM MAY ED TO SCREEN ATTACHED ATTACHED TO THE SCREEN fi w iFp Yi0A2}i CONCRETE BE MT BGM WITH ONE (1) Yi 0 THI BOLT, WRH FENDEDRi WASHER. SCREW ANCHOR O 24' O.G`1^ OR SLOPED ATTACHED TO BEAM OR EAW J Pyu AND 9' MOM POST MPJ I / DIAGONAL BRACING SHALL N( /6- ` O ATTACHED TO ROOF PURU`NB SEE PLAN FOR SIZE Ix2 O.B. FASTENED TO CORNE SECTION WITH I/14.lh' S.M.S. 24. D.C. WA- ANGLE r LONG (FACT W/(2) j14rY* S.M.S . TO POS & 3 8 0 H.O. GALV. 6P. BOI W/ 2 1/2- MIN. EMBEDMENT IV ANGLE, EACH SIDE (TYP.) %'0 CONCRETE ANCHOR W/2%' EMBEDMENT INFO STRUCTURAL CONCRETE (TYP., SEE NOTE 10) �I'x2. O.B. SOLE PLATE . L EDGE OF CO 9, COLUMN/POST 14 0.8, SOLE PLATE S 0 PLAN VIEW REVIEWED FOR CODE -COMPLIANCE SIT. LUCIE-COUN'Y BOCC 3' MIN. aw Y40.T)i CONCRETE z�u SCREW ANCHOR O 24' O.C. AND 9FROM POST )L` , N t 9• COLUMN/POST Ix O.B. SOLE PLATE O O I O OF PLAN VIEW 1• (TYP.) N ANGLE S.M.S POST 2 2.0.D93 BRACE (SEE PLAN) 1x3 O.S. FASTENED TO CORNER SECTION WITH /IOx2' S.M.S. W/ %' CIA. WASHER O IS' O.C. 2x5.W ANGLE (2• LONG) V/ (2)-014 TEKS INTO TOP OF 2x3 CAVE RAIL AND (2)- #14 TENS INTO THE FRONT OF THE CORNER POST 1-1.2 O.B. TOP FRAME CORNER POST -1. O.B. SIOE WALL CORNER UPRIGHT CORNER POST/COLUMN UPRIGHT DETAIL FILE COPY 4 �-2500 PSI MIN. CONCRETE STRENGTH COLUMN MAX. THICK BRICK PAVERS IN MORTAR ON TOP OF FOOTER O.B. SOUE PILATE Z II A 0x5' CONCRETE SCREWS O 24' O.C. 2%' MIN. CONC. tn?.). %' CONIC. EMBEDMENT (MIN.) EMBEDMENT Cm.) TYPCIAL FRONT VIEW OF POST TO FOUNDATION CONNECTION WITH PAVERS 4' NOMINAL CONCRETE SLAB (2500 PSI, MIN.) W/6Y6YIO/10 W.W.N. OR FIBER REINFORCED [POLYPROPYLENE FIBER - 1.5 POUND (MIN.)PER C.Y.) 4d- 4.4 .W `UNDISTURBED SOIL OR COMPACTED CRUSHED UMEROCK (90% PROCTOR) MIN. (1)-05 REBAR CONTINUOUS, SPLICE MUST OVERLAP 20' MIN. 3' COVER (TYP.) DO KIM & ASSOCIATES, LLD CONSULTING STRUCTURAL .ENGINEERS PO Box 10039 Tampa, FL 33679 Tel: (813) 374-0321 ISSUED n � e APPROXIMATE • ,a GRADE ESI a a. 4 A ' a !n 4a• COMPACTED OR Q Is a. a I I — UNDISTURBED SOIL/SAND = W A (1)—#5 REBAR, CONTINUOUS C ' ' 1 — 3' MIN. CONIC. COVER, 36" MIN. LU u—I LAP SPLICE C.)U) 'ITIfkF- y O C J L MIN! Z U UU 1_ Z MIN. CONTINUOUS PERIMETER FOOTING a) LU (4) /12xY.' 2'. PURUN BEAM MAY BE MT OR SLOPED R) 810x2Y" P. EACH R) 810x3Vi P. EACH C Z O 0_ U EL H F L) m Z zi W U co U CL ALTERNATE (1) • �•1•ts' ANGLE U W ❑ F— PLAN - TYPICAL ROOF BRACE TO BEAM CONNECTION 1 E X ANGLE (BRACE) W/ '12XY S.M.S. O MR ER INTERSECTION r ANGLE 2- LONG ON RSIDEW/(4) B12xYi S.M.S LEG (BEAM & BRACE) 3RACE PUN) ALTERNATE 12) 20 BRACE DO YEON KIM, P.E. FLA REG. NUMBER 49497 DO KIM OSSOCLATES, LLC A# 21187 vjOp039 pa, 33679 'Snt•ra FOUNDATION/SLAB DETAIL Drawing No. - 060811 SHEET 2 OF General Notes and Specifications: I. Contractor shall field verify all dimensions before construction and shall notify engineer of discrepancies for immediate consideration. 2. Concrete shall be minimum 28 day compressive strength of f'c=2500 psi, and be in accordance with the requirements of ACI 318. Reinforcing steel shall have a -min. yield -strength of 40,000 psi (grade 40) and be -provided with cover in accordance with ACI 318. 3. All dimensions are provided by contractor, DO Kim & Associates, LLC have made interpretations where necessary. 4. The following structures are designed to be attached to block and wood frame structures of adequate structural capacity. The contractor shall verify that the host structure is in good condition and of sufficient strength to hold the proposed addition. If there is a question about the host structure, the owner (at his own expense) shall hire an architect or engineer to verify host structure capacity. 5. Screen density shall be a maximum of 18 x 14 x 0.013" mesh. Aluminum shall be 7005-T53 Alloy, 6005-TS Alloy; for secondary components 6063-T6, Alloy based on industry standard shapes, thicknesses, and tolerances unless otherwise noted. 6. Unless otherwise noted, SMB shall be stitched with #100/4" SMS at 24"o.c., top and bottom. 7. Connections using screw bosses shall have minimum (4)410x2•' per connection unless shown otherwise. 8. Unless otherwise shown srrpws chnll hzvo minimum e V e X&& - -- --A ---L__ a_ _ this table. CD w1uWII III 1-1022 Low Carbon Steel SMS & Self -Drilling (TEK) Screws (Industry Standard Screws) Screw Nominal Screw Diameter (in) Minimum Edge Distance Minimum Center to Center Distance #10 0.188 6/„" +/2" #12 0.219 #14 (1/4") 0.250 V2 s/e„ 9. Structure has been designed to meet the 61° Edition FBC (2017 FBC). Project is sited where the ultimate design wind speed, VW1, is 150 mph (3-sec gust) for risk category I buildings and other structures. Exposure C. Design pressures are from Table 2002.4, 2017 FBC reduced by 0.88 for screen mesh factor, 0.6 for allowable stress design (ASO). 10. Concrete anchors may be "Large Diameter Tapcons'•(LTOs), Tapcon concrete screws, Simpson Strong -Tie Anchors or Titian Screws or approved equal. 11. Screen enclosure structure shall meet Section 454.2.17 Residential Swimming Barrier Requirements and the screen enclosure per 454.2.17.1.11. if enclosing a pool. FILE COPY REVIEWED FOR COD E COMPLIANCE ST. LUCIE COUNTY BOCC DO KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tampa, FL 33679 Tel: (813) 374-0321 ISSUED J_ Q F- UJ Ci 0 C � W U c O U U Z w a+ w c Z � a O 0 - J Z U U w rn d U 0 DYK DO YEON KIM, P.E. FLAL REG. NUMBER 49497 DO g�A#AF6887 TES, LLC 39 679 I Drawing No. - 060811 I SHEET 3 OF FND CM � t 2 TRACT 2 UNREADABLE B NSB aggq ,. ; 15.22 GOLF COURSE 9sFeE?4" •,� : _ YF FND 4X4 CM 95.00, N 9"1 UNREADABLE A FILE COPY LOT 7 - VACANT 37.4, 17.19 -` X •Q x �' CY 1B Q REVIEWED FOR 16,06 b CODE COMPLIANC�� ,� TT . .09 �,�?. LUCIE COUNT LOT 6 SCREENED ST. r7 CONCRETE: A/C BOCC R! 1 STORY CBS �No ;1. P FFE=17.50' \ 3gr.17.29'1 COVERED �� FND % IR ENTRY NO ID 15. 15.39 -1,o 76 O0 , ASPHALT ' /•:; :.-.:7 17.31 .,.,.+ to 0 17.40 6 • `I •„ 15.5 R 40 , 00 , ASPHALT 15,q 1 4o p8 $3 " 5 x 15.87 :DEAN 5.87 RZ 0'80, da 2/ 0 1 s,S3" x 15.75 C/L MEADOWOOD Dk< MONTE CARLO BOULEVARD (PER PLAT) 80, WIN ASPHALT VARIES FND % IRC RLS# 2391 W ,oundary * Topograph Survey For: 15.36 John * Dada Snowe ' STREET ADDRESS: FND % IRC 9410 MEADOWOOD DRIVE, FORT PIERCE, FL 34951 {UNREADABLE- - _ LEGAL -DESCRIPTION: -- LOT 6, MONTE CARLO COUNTRY CLUB. UNIT ONE. MIN. K.RE SETSg C, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN FRONT Q PLAT BOOK 23, PAGES 25, A-B. OF THE PUBLIC RECORDS OF SAINT LUCIE COUNTY, FLORIDA. SIDES CNR SIDES_ q. LIVE <i l Jg TE( , m j WELL K 15.68 W WALL. z m r� S 8961849" E 1m 30.01, M 15.79 LOT 5 OCCUPIED FFE=17.10' FND a IRC RLS # 2391 16.54 15,18 15.57 ' 16.44' 16.25 15.71 15.20 LEGEND * ABBREVIATIONS: A ARC LENGTH A/C AIR CONDITIONER ORS �(TD TRECORDS BOOK m BUILDING SETBACK UNE PB PLAT BOOK C CALCULATED FROM FIELD MEASUREVENTS PCP PER►IANERT CONTROL POINT CBS CONCMTE BLOCK STRUCTURE PG(S) PAGES) CONC CONCRETE PeaCINKM CM CONCRETE MONUMENT MONUMENT PGC POINT KF POINT OF �COYX MCFSNENT CA CENTERUNE PSM PROFESSIONAL SURVEYOR & MAPPER D&IUE DRAINAGE & UTILITY EASMMLT R RAWUS V" ELEVATION R/W RIGHT OF WAY FIT FINISH FLOOR ELEVATION TTm TOP OF BANK FOUND Yes TOE OF SLOPE ID =110H NUMBER � (MENT am PIPE ION WATIIt METER [Re RON ROD & CAP � MANHOLE LB LICENSED GUSKESS DELTA M az � + DATA E mme smcE sox NAVD NORTH AMERfGW VMTICAL DATUM TELEPHONE EERNCE sox OHP Q%OWAD GDUREs GENERAL NOTES: 1. THE BEARINGS SHOWN HEREON ARE REFERENCED TO THE NORTH UNE OF LOT 7 HAVING A BEARING OF N58'04'24-W, ACCORDING TO THE PLAT OF PORT SAINT LUCIE SECTION , AS RECORDED IN PLAT BOOK 23, PAGE 25, A-B, PUBLIC RECORDS. SAINT LUCIE COUNTY, FLORIDA.(AS SHOWN.) 2. FLOOD NOTE: BY GRAPHIC PLOTTING ONLY, THIS PROPERTY IS IN ZONE "X", ACCORDING TO THE FLOOD INSURANCE RATE MAP, COMMUNITY PANEL NO. 12111 C 0160 J, EFFECTIVE DATE FEBRUARY 16, 2012. THE EXACT DESIGNATION CAN ONLY BE DETERMINED BY AND ELEVATION CERTIFICATE. 3. ELEVATIONS. IF SHOWN, ARE IN NORTH AMERICAN VERTICAL DATUM (NAVD) OF 1988. 3. ALL ABOVE GROUND FIXED IMPROVEMENTS. IF ANY, HAVE BEEN LOCATED AND SHOWN HEREON. 4. UNDERGROUND UMUTIES AND UTILITY SERVICES HAVE NOT BEEN LOCATED ON THIS SURVEY. S. LANDS SHOWN HEREON WERE NOT ABSTRACTED BY THIS OFFICE FOR RIGHTS -OF -WAY, EASEMENTS OF RECORD, OWNERSHIP, ABANDONMENT'S DEED RESTRICTIONS, OR MURPHY ACT DEEDS 6. REPRODUCTIONS OF THIS MAP ARE NOT VAUD WITHOUT THE SIGNATURE AND ORIGINAL RAISED SEAL OF A FLORIDA UCENSED SURVEYOR & MAPPER. 7. ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS BY OTHER THAN THE SIGNING PARTY OR PARTIES IS PROHIBITED WITHOUT WRITTEN CONSENT OF THE SIGNING PARTY OR PARTIES. B. THE LAST DATE OF FIELD WORK WAS DUNE 09. 2017. CERTIFIED TO: o / ��C.. Q COPYRIGHT ARNOLD SURVEYING, INC. 2017 JOB NO. 17-538 AVIOLD A71dYl.Y7Cf.i 11%. INC. JOHN C. SNOWE; `�// /� ALL DRAVANG5 KM DOCUMENP5 AND COPIE5 THEREOF ARE INSTRUCTIONS DATE: 06 17 P[tD�ssDN SURVEYORS DARLA A. SNOWE; OF 5ERVICE AND REMAIN THE PROPERTY OF ARNOLD SURVEYING, INC. THE REPRODUCTION OR UNAUTHORIZED USE OF THE5E DRAVANG5 OR ANY =,30' SCALE: 1"=30 BUSINESS NUMSM 7903 FLORIDA LICENSED BUSINESS NUMBER 7903 CE /� �g�/�� R GHMU,�S .C1iAylTLVK> D DATE SIGNED PROFESSIONAL SURVEYOR & MAPPER OTHER PROJECT DOCUMENT5 WITHOUT WP.BTTEN PERMI55ION FROM AP.NOLD 5URVETING, INC. 15 5TRICTLY PROHIBITED, THIS ORAWING OR DRAWN BY: CA REVIEWED BY: CA 488E N. KINGS HI H VIAY 1425. FORT POM FLORIDA 34951 24 %V= NSTA. FORT POM FLORIDA 34951 FLORIDA LICENSE NO: 4971 DOCUMENT 15 PROTECTED BY FEDERAL COPYRIGHT LAWS. (772) 460-8211 SURVEYCASI-SURVEY.COM