Loading...
HomeMy WebLinkAboutEVALUATION REPORTMAR 14 2019 ENGINEER EVALUATE TEST %I uATION RFPOF NEMO I etc. Certificate of Authorization N32455 permitting 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 CONSULT CERTIFY Owens Corning Roofing and Asphalt, LLC Evaluation Report 111980.11.08-R8 One Owens Corning Parkway FL11602-R7 Toledo, OH 43659 Date of Issuance: 11/03/2008 (740)321-6345 Revision 8:09/14/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sgJcdA herein. BY DESCRIPTION: Titanium'" Roof Underlayments St. Lucie County LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOI etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPEcrION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: me;;nr".. — •`d.'."^.:$jo Robert J.M. Nieminen, P.E. �. The facsimile seal appearing was authorized byRobert Florida Registration No. 59166, Florida OCA ANE1983 s`Ou>tE'li . `:.:y�,,,,;,,;,,..'` Nieminen, P.E. on 09/14/zoia. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have norwill acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity Involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO Ietc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMOletc. ROOFING COMPONENT EVALUATION: e• Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Titanium' Roof Underlayments, as produced by Owens Corning Roofing and Asphalt, LLC, have demonstrated compliance with the intent of the following sections of the 611 Edition (2017) Florida Building Code through testing in accordance with applicable sections the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Pro a Standard year 1507.1.1, R905.1.1 Exception Unrolling, Breaking Strength, Pliability ASTM D226 2009 1507.1.1, R905.1.1 Exception Tear Strength ASTM D1970 2015 1507.1.1, T1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 (04-12) 2012 TA5110 Accelerated Weathering ASTM D4798 2011 TAS 110 Pull -through resistance TAS 117(B) 1995 -3. REFERENCES: Enti Examination Reference Date ERD (TST6049) Physical Properties 115010.04.09 04/29/2009 ERD (TST6049) Physical Properties 115010.05.10 05/14/2010 ERD (TST6049) Physical Properties 135520.06.11 06/15/2011 ERD (TST6049) ASTM D226 138010.08.11 08/11/2011 ERD (TST6049) Wind Uplift 135520.08.11-1 08/12/2011 ITS(TST1509) ASTM D226 311801000Q-003 04/26/2007 ITS(TST1509) ASTM D226 3130639COQ-002A 08/21/2007 ITS(TST1509) Physical Properties 3126617COQ-005 10/31/2007 ITS(TST1509) ASTM D226 101823107COQ-011 01/23/2015 Owens Corning Product equivalency Declaration 06/18/2018 PRI (TST5878) ASTM D1970 OCF-341-02-01 09/20/2017 PRI (TST5878) ASTM D1970; Tear strength OCF-331-02-02 10/03/2017 PRI(TST5878) ASTM D1970; Tear strength OCF-332-02-02 10/03/2017 PRI(TST5878) ASTM D1970; Tear strength OCF-334-02-02 10/03/2017 PRI (TST5878) FRSA/TRI April 2012 (04-12), partial OCF-343-02-01 11/09/2017 PRI(TST5878) ASTM D4798 OCF-341-02-01 11/27/2017 PRI (TST5878) TAS 117(B); Pull -through OCF-422-02-02 04/03/2018 PRI (TST5878) FRSA/TRI April 2012 (04-12), partial OCF-425-02-01 08/13/2018 ITS (QUA1673) Quality Control ITS Listings Current ITS (QUA1673) Quality Control Service Confirmation 09/30/2017 4.1 Titanium`"' PSU-30 is an unreinforced polymer modified bitumen material adhered to the underside of a polymer - coated, synthetic woven sheet. The underside is backed with a release film. Unit weight 24 Ibs/square. Meets ASTM D1970 and FRSA/TRI April 2012. NEMO ETC, LLC Evaluation Report 111980.11.08-R8 Certificate o7Authoriaotlon a32455 6r" EDITION (2017) FBC NON-HVHZ EVALUATION F1.11602-117 Titanlum Roof Undedayments Revision 8: 09/14/2018 Page 2 of 7 NNEMOletc. 4.2 Mechanically Fastened Underlayments: 4.2.1 TitaniumTM UDL-25 is a synthetic sheet -type underlayment comprised of a woven core coated on one side with a polymer coating. Unit weight 2.5lbs./square; meets FBC 1507.1.1 & R905.1.1 (Exception). 4.2.2 Titanium'"' UDL-30 is a synthetic sheet -type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 4.01bs./square; meets FBC 1507.1.1 & R905.1.1 (Exception). 4.2.3 TitaniumTM UDL-50 is a synthetic sheet -type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 4.7lbs./square; meets FBC 1507.1.1 & R905.1.1 (Exception). 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report Is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Titanium^" Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: `y�'/, 5.5.1 TABLE I: .. OOD SHAKES UNDERLAYMENT 5 Nilli I E FG-PI OP1371 E METAL SHINGLES SLATE Titanium PSU-30 Yes (Dubai, UAE) yes Yes (See 5.5.1) Yes es Titanium PSU-30 (Brentwood, NH) Ye es No Yes Yes Yes itanium UDL- s N Yes Yes Yes es Yes Titani L-30 Yes le.. Shaetln3 Iy (Ba sheet in ly 5 5 system) system) Tita um UD 0 Yes No No Yes Yes Yes "Foam -On Tile" is limited to use of following Approved tile adhesives / underlayment combinations. Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance NEMO ETC, LLC Evaluation Report 111980.11.08-RB Certificate ofAuthariration a32455 6Te EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R7 Titanium Roof Underlayments Revision 8: 09/14/2018 Page 3 of 7 ONEMO etc. 5.6 Allowable Substrates: Titanium PSU-30: 5.6.1 Direct -Bond to Deck: ➢ New untreated plywood; ➢ Existing untreated plywood, primed as needed with D41 primer to achieve bond. 5.6.2 Bond to Mechanically Attached Base Sheet: ➢ ASTM D226, Type I or II felt. ➢ Titanium UDL-30 (primed with D41 primer) or UDL-30 (inverted). 5.6.3 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads. 81 Maximum Design Pressure = -45 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 Underlayment: One or two plies, Titanium PSU-30 (Dubai, UAE), self -adhered and back -nailed max. 12" o.c. in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. #2 Maximum Design Pressure =-30 psf•: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (inverted) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps Spacing: 6-inch o.c. at 4-inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required at all tin -caps. Underlayment: One or two plies, Titanium PSU 30 (Dubai, UAE), self -adhered and back -nailed max. 12" o.c. in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. #3 Maximum Design Pressure =-30 osf• Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (printed side up) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps. Spacing: 6-inch o.c. at 4-inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: One or two plies, Titanium PSU 30 (Dubai, UAE), self -adhered and back -nailed max. 12" o.c. in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. NEMO ETC, LLC Evaluation Report 111980.11.08-R8 certificate of Authorization N32455 6"EDITION (2017)FRC NON-HVHZ EVALUATION FL11602-R7 Titanium Roof Underlayments Revision 8: 09/14/2018 Page 4 of 7 ONEMOletc. #4 Maximum Design Pressure=-45 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (inverted) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps Spacing: 6-inch D.C. at 4-inch wide side laps and 8-inch D.C. at three (3), equally spaced center rows. Primer: ASTM D41 primer required at all tin -caps. Underlayment: One or two plies, Titanium PSU 30 (Dubai, UAE), self -adhered and back -nailed 12" D.C. in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. #5 Maximum Design Pressure = -45 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (printed side up) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps. Spacing: 6-inch D.C. at 4-inch wide side laps and 8-inch D.C. at three (3), equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: One or two plies, Titanium PSU 30 (Dubai, UAE), self -adhered and back -nailed 12" o.c. in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. 5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD3, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Titanium UDL-25, Titanium UDL-30 or Titanium UDL-50 shall not be left exposed for longer than 30-days. Titanium PSU-30 shall not be left exposed for longer than 180-days. 5.8 Tile Slippage Limitations [per FRSA/TRI April 2012 (04-12)1: When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE2: TILE SLIPPAGE UrviiTATiONS FOR DIRECT -DECK UNDERLAYMENT TILE PROFILE STAGING METHOD MAXIMUM SLOPE Titanium PSU-30 (Dubai, UAQ Flat Max. 10-tile stack 5:12 Lugged Max.10-tile stack 6:12 Titanium PSU-30 (Brentwood, NH) Tiles shall be loaded and staged atop battens, regardless of tile profile or slope NEMO ETC, LLC Evaluation Report 111980.11.08-R8 Certificate afAuth.rization #32455 6- EDITION (2017) FBC NON-HVH2 EVALUATION FL11602-R7 Titanium Roof Underlayments Revision 8: 09/14/2018 Page 5 of 7 NNEMO I etc. 6.1 Titanium Roof Underlayments shall be installed in accordance with Owens Corning Roofing ano4sphalt,. published installation requirements subject to the Limitations set forth in Section 5 herein an a specifi cited below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Swee he substra th oughly to remove any dust and debris prior to application, and prime the substrate (if app' able). 6.3 Titanl '" UDL-25, Titanium UDL-30 or Titanium.UDL-50: 6.3.1 Shall be ins-fa4ed in compliance with the requirements for ASTM D , Type I or'll u ayment in FBC Table 1507.1.1 or R90 . 1 for the type of prepared roof covering to b _'stalled, cord a wider sheet -width. 6.3.2 Fasteners: Mechanical attachment o itanium UDL-25 and Tita i mtUDL-3l' d to ring shank roofing nails with minimum 1-inch diameter plas caps. Mechanical attachment of Titanium L-50 is i ited tongs oofing nails with minimum 3/8-inch diameter heads; ring shank roofing nails with mini m 1-inch dame a astic caps; screws and plates; or plastic cap staples. 6.3.2.1 Code Reference: The Exception statQment in 07 . and FBC R905.1.1 states: "...except metal cap noilsshall be required where the ultimate design windV`ee awc equals or exceeds 150 mph." Owens Corning Roofing an Asphalt, LLCh rnishe ata to permit the use of 1-inch diameter plastic cap nails in lieu of metal cap n�l or these p>I' Ions, when the nium'"` UDL-25, Titanium UDL-30 or Titanium UDL- 50 underlayment i 'nstalled be0e mechanically fastened pre red roof covers referenced in FBC Table 1507.1.1 or R905.1.1� 6.3.3 Slo es ofA:l or rea End (- ertic la 1- a minimum 6-inches and side (horizontal) laps shall minimum 4-inches. inimu a went shall be in accordance with FBC Table 1507.1.1 or R905.1. When batten systems are to be inst a pp the underlayment, the underlayment need only be preliminarily atta d pending attachment of S. 68.4 Sl - of 2:12 to less than 4:12: uble layer application; begin by fastening a 25-inch wide strip along the eaves. Place a full -width s et over the arter, completely overlapping the starter course. Continue as noted in 6.3.3, but maintaining minimu -inch T� side (horizontal) laps, resulting in a double -layer application. 6.4 " Titanium- PSU-30: 6.4.1 Non -Tile Installations: Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed, and Owens Corning published requirements. Titanium'" PSU-30 shall be back -nailed max. 12" D.C. in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. e installed in compliance with the requirements for Self -Adhered Membrane underlayment set forth in PRSA/TRI April 2012 (04-22), and Owens Corning published requirements. Titanium'" PSU-30 shall be back -nailed max. 2" o.c. in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and Owens Corning Roofing and Asphalt, LLC published requirements for tile staging. NEMO ETC, LLC Evaluation Report 111980.11.08-R8 Certificate of Authorization#32455 67" EDITION (2017) FBC NON-HVHZ EVALUATION F1.11602-117 Titanium Roof Underlayments Revision 8: 09/14/2018 Page 6 of 7 ONEMOletc. Titanium 2-Ply System: 6.. The Titanium 2-Ply System consists of a base layer of Titanium UDL-30 (top -surface primed or sheet inverted) mechanically attached to the wood roof deck followed by Titanium PSU-30, self -adhered. 6.5.2 Non -Tile Applications: Install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with Section 6.3 followed by Titanium PSU-30 in accordance with Section 6.4. Tile Applications: For nail -on the installations, install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with FRSA/TRI April 2012 (04-12), using Section 6.3 as a guide, and considering the wider sheet width relative to ASTM 226 felt. Then apply Titanium PSU-30 in accordance with Section 6.4. For adhesive -set tile roofing, refer to Section 5.6.3 herein. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and Owens Corning Roofing and Asphalt, LLC published requirements for tile staging. -7. E�jIUJING PERMIT IRECUI`REMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. Contact the noted CIA agency for information on product locations covered for F.A.C. 61G20-3 CIA requirements. The following plants have qualified products under their respective physical properties specifications. Plant Specification Product s Mission, BC, Canada FBC 1507.1.1(Exception) Titanium UDL-30; Titanium UDL-50 Qingdao, China FBC 1507.1.1 (Exception) Titanium UDL-25; Titanium UDL-30; Titanium UDL-50 Dubai, UAE FRSA/TRI 04-12 (2-ply system) Titanium PSU-30 (Dubai, UAE) Brentwood, NH ASTM D1970, FRSA/TRI 04-12 Titanium PSU-30 (Brentwood, NH) QUALITY,9. Intertek Testing Services NA Inc.—QUA1673; (604) 520-3321 - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 111980.11,08-R8 Certificate of Authorization #32455 0 EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R7 Titanium Roof Underlayments Revision 8: 09/14/2018 Page 7 of 7