HomeMy WebLinkAboutEVALUATION REPORT - EAGLE ROOF TILESQIQTRINITYIERD EVALUATION REPORT Eagle Roofing Products Florida LLC. 1575 East Country Road 470 Suniterville, FL 33585 (800)400-3245 SCOPE: EXTERIOR RESEARCH & DESIGN, I.I.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT-06478 (203)262-9245 Evaluation Report E1322.09.06-RS FL7473-R8 SCANNED Date of Issuance:02/24/2009 BY Revision 5: 10/16/2017 St. Lucie County This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6Th Edition (2017) Florida Building Code (NON-HVHZ) sections noted herein. DESCRIPTION: Eagle Roof Tiles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Evaluated by Robert Nieminen, P.E." may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5. Prepared by: a.� Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The fauimlie seal appearing was authorised by Robert Nieminen, P.E. on 10116/2017. This does not serve as an eleuroNrally signed document. Signed, sealed hardoopies have been transmitted to the Produtt Approval Administrator and to the named dlent CERTIFICATION OF INDEPENDENCE: 1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity Involved In the approval process of the product. S. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. `J TRINITY ERD ROOFING SYSTEM EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roofing Tiles Compliance Statement: Eagle Roof Tiles, as produced by Eagle Roofing Products Florida LLC, have demonstrated compliance with the following sections of the EP Edition (2017) Florida Building Code (NON-HVHZ) through testing in accordance with the following Standards._ Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2.' STANDARDS: Section 1507.3.5, R905.3.5 1507.3.7, R905.3.7 1504.2.1.1 3. REFERENCES: gniitt ATL(TST 3782) ATL(TST 3782) Tile Roof Institute ATI (QUA 1844) 4. PRODUCT DESCRIPTION: 4.1 FASTIVI C3492, Pro e Physical Properties Attachment Requirements Overturning Moment Examination ASTM C1492 ASTM C1492 — Freeze/thaw SSTD 11 Quality Assurance Standard Year ASTM C1492 2003(2009) FRSA/TRI April 2012 (04-12) 2012 SSTD 11 1997 Reference Date RT0310.01-17, 02-17, 03-17 03/15/2017 RT0706.01-17,02-17, 03-17 09/25/2017 Membership Letter 11/29/2005 Ips c I eport 06/07/2017 BELAIR Exterior Research and Design, I.I.C. 6r" EDITION (2017) FBC NON-HVHZ EVALUATION Evaluation Report E3322.09.05-RS Certifleote o)Authorhation #9503 Eagle Roofing Products Florida LLC.; (800) 400-3245 FL7473-RB Revision 5: 10/2612017 Page 2 of S 4.2 1 ASTM C1492, Type II (Medium Profile): I MALIBU NAIL HOLE 4.3 1 ASTM C1492, Type I (High Profile): S. LIMITATIONS: TRINITY I ERD 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire classification is not part of this evaluation; refer to FBC 1505.2, Exception 2 (for non-combustible deck) or listing by an approved testing agency for fire rating of this product. 5.4 5.5 Underlayment shall be that which holds Florida Product Approval for use with tile roofing systems. The underlayment Product Approval shall specify allowable method(s) of tile installation (mechanical attachment, mortar -set and/or adhesive -set) for use with the specific underlayment. For mortar -set or adhesive -set tile roofing applications, the underlayment Product Approval shall specify attachment methods for the underlayment system to resist wind uplift design loads in accordance with Table SA of FRSA/TRI April 2012 (04-12). "Color -Bonded" or "Slurry -Coated" files are limited to use on projects in areas subjected to weathering indices of 50 or less (negligible weathering), as outlined in Figure 1 of ASTM C1492-03(2009)I, reproduced below for reference. This limitation does not apply to the "Color -Through" product offering. 50 WEATHERING REGIONS t :V NEGLIGIBLE WEATHERING MODERATE WEATHERING ••l;~ SEVERE WEATHERING 5.6 All products in the roof assembly shall have quality assurance audit in accordance with FAC Rule 611320-3 Exterior Research and Design, U.C. 6r" EDITION (2017) FBC NON-HVHZ EVALUATION Evaluation Report E3322.09.06-RS Cert07cate cfAuthort:ation N9503 Eagle Roofing Products Florida LLC.; (800) 400-3245 FL7473-R8 Revision 5: 10/16/2017 Page 3 of 5 JTRINITY 1� ERD 6. INSTALLATION: 6.1 Eagle Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall comply with manufacturer's current published instructions, but not less than the requirements of FBC 1507.3 and the FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual. 6.2 Underlayment shall be installed in accordance with FRSA/TRI April 2012 (04-12) or the underlayment manufacturer's current Product Approval. For mortar -set or adhesive -set tile roofing applications, the underlayment current Product Approval shall specify attachment methods for the underlayment system to resist wind uplift design loads in accordance with Table 1A of FRSA/TRI April 2012 (04-12). 6.3 Tile Attachment: 6.3.1 _Mechanically Attached Tile: Wind load resistance shall be in accordance with Table 3 of FRSA/TRI April 2012 (04-12) to resist the Uplift Moment determined in Table 2A or 2B of FRSA/TRI April 2012 (04-12) or FBC 1609.5.3. 6.3.2 Mortar -Set Tile: Wind load resistance shall be in accordance with Table 2A or 2B of FRSA/TRI April 2012 (04-12) or FBC 2609.5.3 in conjunction with the mortar manufacturer's Product Approval. 6.3.3 Adhesive -Set Tile: Wind load resistance shall be in accordance with Table 2A or 2B of FRSA/TRI April 2012 (04-12) or FBC 1609.5.3 in conjunction with the adhesive manufacturer's current Product Approval. Refer to the current version of the referenced Florida Product Approval for paddy -placement details and performance data. TILE ADHESIVES FOR ADHESIVE -SET TILE SYSTEMS Manufacturer Products Florida Product Approval DAP Foam, Inc. 'Touch N'Seal Storm Bond" FL14506 'Touch N' Seal Storm Bond 2" FL21374 Dow Chemical .'TILE BONDTM" FL22525 ICP Adhesives & Sealants, Inc. "Polyseta AH-160" FL6332 "Polyset® RTA-1" FL6276 6.3.4 Hip and Ridge Tile: Tile shall be installed in accordance with FRSA/TRI April 2012 (04-12). For hip and ridge tile installations atop hip and ridge metal, refer to the hip and ridge metal manufacturer's current Product Approval (e.g., FL5374) or test report in accordance with SSTD 11 for allowable loads to resist those determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12). Exterior Research and Design, U.C. 6"EDITION (2017) FBC NON-HVHZ EVALUATION Evaluation Report E1322.09.06-RS Certilimte of Authorization N9503 Eagle Roofing Products Florida LLC.; (800) 400-3245 FL7473-R8 Revision 5: 10/16/2017 Page 4 of 5 4 \ \I I PJNITY J ERD 7. LABELING: 7.1 Each unit shall bear the imprint or identifiable marking of the manufacturer's name or logo.. Tile lots shall be labeled in acccWdance with the requirements of the Accredited Quality Assurance Agency noted herein. EAGLEIM" FLORIDA EAGLE FL (LOCATED ON UNDERSIDE OF TILE) (LOCATED ON FRONISIDE OF TILE) 7.2 Tile not tested for freeze -thaw shall state clearly that the lot has not been tested for freeze -thaw acceptance on all lot tags or certification. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Sumterville, FL 10. QUALITY ASSURANCE ENTITY: Architectural Testing, Inc.—QUA1844� (717) 764-7700 - END OF EVALUATION REPORT - ASTM C1492-03, Standard Specification for Concrete Roof Tile, O ASTM International Exterior Research and Design, I.I.C. e" EDITION (2017) FBC NON-HVHZ EVALUATION Evaluation Report E3322.09.06-RS Cert!i lmte o/Aut4orundon 49503 Eagle Roofing Products Florida LLC.; (800) 400-3245 FL7473-RB Revision 5: 10/16/2017 Page SofS EXTERIOR RESEARCH St DESIGN, U.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT 13 OXFORD, CT 06478 (203)262-9245 EVALUATION REPORT ICP Adhesives and Sealants, Inc. Evaluation Report 02768.03.06-118 12505 NW 44tb Street SCANNED FL6332-RS Coral Springs, FL 33065 BY Date of Issuance:08/O8/2008 (888)774-1419 St. Lucie County Revision 8: 10/12/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: ICP Adhesives Polyset® AN-160 LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words `Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPEcnoN: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCAANE1983 TRINITY I ERD The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 10/12/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, U.C. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financlaI interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, L-C. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity Involved in the approval process of the product. S. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, In any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY I ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roof Tile Adhesives Compliance Statement: ICP Adhesives Polyset® AH-160, as produced by ICP Adhesives and Sealants, Inc., has demonstrated compliance with the 6' Edition ,(2017) Florida Building Code through testing in accordance with the Standards set forth herein. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Sections Property Standard Year 1504.2.1.1 Overturning resistance SSTD 11 1997 3. REFERENCES: gniky Examination Reference Date ERD (TST 6049) Static Uplift—SSTD 11 P39740.02.12 02/20/2012 ERD (TST 6049) Static Uplift—SSTD 11 P39740.11.13-R1 01/02/2015 ICC-ES(EVL2396) 20121BC Compliance ESR-1709 12/01/2016 Miami -Dade (CER 1592) HVHZ compliance 17-0322.03 04/27/2017 PRI (TST 5878) Static Uplift—SSTD 11 ECM-001-02-01 09/21/2001 PRI (TST 5878) Static Uplift—SSTD 11 PFI-006-02-01 05/09/2005 PRI (TST 5878) Static Uplift—SSTD 11 PFI-006-02-02 OS/09/2005 PRI (TST 5878) Static Uplift—SSTD 11 PFI-007-02-01 10/11/2005 PRI (TST 5878) Static Uplift—SSTD 11 PFI-008-02-04 02/21/2006 PRI (TST 5878) Static Uplift—SSTD 11 PFI-009-02-03 02/21/2006 PRI (TST 5878) Static Uplift—SSTD 11 TGRI-001-02-03 10/30/2006 PRI (TST 5878) Static Uplift—SSTD 11 TGRI-001-02-03 10/30/2006 PRI(TST5878) Static Uplift—SSTD 11 PFPI-010-02-01 12/07/2006 PRI (TST 5878) Static Uplift—SSTD 11 PFPI.011-02-01 12/07/2006 PRI (TST 5878) Static Uplift—SSTD 11 PFPI-012-02-01 12/07/2006 PRI (TST 5878) Static Uplift—SSTD 11 PFPI-013-02-01 12/07/2006 PRI (TST 5878) Static Uplift—SSTD 11 PFPI-014-02-01 12/07/2006 PRI (TST 5878) Static Uplift—SSTD 11 ECM-003-02-01 06/13/2008 PRI (TST 5878) Static Uplift—SSTD 11 ECM-004-02-01 06/13/2008 PRI (TST 5878) Static Uplift— SSTD 11 ECM-005-02-01 06/13/2008 PRI (TST 5878) Static Uplift—SSTD 11 ECM-006-02-01 06/13/2008 FRI(TST 5878) Static Uplift —SSTD 11 ECM-007-02-01 06/13/2008 PRI (TST 5878) Static Uplift—SSTD 11 ECM-008-02-01 06/13/2008 UL LLC(QUA 9625) Quality Assurance Service Confirmation Exp. 06/05/2018 4. PRODUCT DESCRIPTION: 4.1 ICP Adhesives Polyset® AH-160 is a two -component expanding polyurethane roof tile adhesive that is mixed and dispensed from a dispensing system provided by ICP Adhesives and Sealants, Inc. The components are available in refillable tanks or disposable cylinders (ICP Adhesives Pro Pack® 30 & 100). S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. Exterior Research and Design, LLC. Evaluation Report 02768.03.06-RS Cert1fimte OfAuthodza8an M503 6' EDITION(2017) FBC NON-HVHZ EVALUATION FL6332-RB ICP Adhesives Polyset- AH.160: (888) 774-1419 Revision 8: 10/12/2017 Page 2 of 9 �J\TRINITY ERD 5.3 Fire classification is not part of this evaluation. Refer to a current Roofing Materials Directory for fire ratings of this product and FBC 1505.2. 5.4 ICP Adhesives Polyset® AH-160 can be used with flat, low and high profile tiles or any rigid, discontinuous roof assembly having a current Florida Statewide Product Approval or approved on a local -level by the Authority Having Jurisdiction. 5.5 Minimum underlayment shall be per FRSA/TRI April 2012 (04-12) or having a current Florida Statewide Product Approval or approved on a local -level by the Authority Having Jurisdiction for use with ICP Adhesives Polyset® AH-160. 5.6 Field tiles, meeting the limitations of FBC 2609.5.3, using ICP Adhesives Polyset® AH-160 are limited to projects having an Aerodynamic Uplift Moment (Ma), determined in accordance with FBC 1609.5.3 or Tables 2A and 2B of FRSA/TRI April 2012 (04-12), not greater than the following Allowable Overturning Moment values. Refer to Section 10 and ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. TABLE 1: FIELD TILES IN ICP ADHESIVES POLySETO AH-160 ALLOWABLE OVERTURNING MOMENTPERFORMANCE DATA 2 701 MARGINOFSAFEFYAWMDYAPPUEDFORINDEPENDENT(SINGU:ORCONnN000SPADDY) PUICEMENT 4Tu 1 MARG/NOFSAFETYAU EWYAPPUEDFOR INTERDEPENDENT (TWO PADDY) PIACEMENF Tile (FBC 1609.5.3) Adhesive Paddy Placement Allowable Overturning Type Profile Moment (ft-lbf) Independent; Single Paddy, Medium (20-inch, -30 gram) 60 Clay or Concrete Flat Independent; Single Paddy, Large (2x10-inch, -45 gram) 112 Interdependent; Two Paddy (44-inch on underlayment, 2x4-inch at tile overlap) 54 independent; Single Paddy, Medium (20-inch,-30 gram) 39 Clay or Concrete Low/ Medium Independent; Single Paddy, Large (2x10-Inch,-54 gram) 67 Interdependent; Two Paddy (4x4-inch on underlayment, 2x4-inch at tile overlap) 58 Clay High Independent; Single Paddy, Large (240-Inch, -45 gram) 134 Clay or Independent; Single Paddy, Medium (2x7-inch, -30 gram) 65 Independent; Single Paddy, Large (2x10-Inch, -63 gram) 109 Concrete High Interdependent; Two Paddy (4x4-Inch on underlayment, 2x4-Inch at tile overlap) 40 Clay Barrel 2x10-inch x ^35 gram for pans; 2 @ 1x10-inch x ^17 gram for cap 147 Concrete Barrel 2x10-inch x `35 gram for pans; 2 @ 1x10-inch x ^17 gram for cap 107 ClayCap atop 2x Independent: Continuous Paddy p Y ('"34 gram/ft) 135 stringer Concrete Cap atop 2x Independent: Continuous Paddy p Y ("" 34 gram/ft) 116 stringer Clay Cap atop 2x Interdependent: stringer Head: One (1) #10 x 2X" screw; Overlap: 1 x 6 inch (^10.5 gram) 105 Concrete Cap atop 2x Interdependent: 76 stringer Head: One (1) #10 x 2%" screw; Overlap:1 x 6 inch (^10.5 gram) 5.6.1 Data in Table 1 relates to installation over a '30/90' underlayment system, as detailed in the FRSA/TRI April 2012 (04-12). Alternate underlayment systems include those having a current Florida Statewide Product Approval and/or approved on a local -level by the Authority Having Jurisdiction specifically for use with ICP Adhesives Polyset® AH-160. 5.6.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with ICP Adhesives Polyset® AH-160 shall be tested in accordance with SSTD 11 or Testing Application Standard TAS 101. For the interdependent two -paddy method, an additional 2-to-1 margin above that specified in SSTD 11 or Testing Application Standard TAS 101 shall be applied in determining the 'allowable overturning moment'. Exterior Research and Design, U.C. Evaluation Report 02768.03.06-RB CerdPcate afAuthaN:atlon 49503 6'"EDITION (2017)FBC NON-HVHZ EVALUATION FL6332-RB ICP Adhesives Polyset• AH-160; (888) 774-1419 Revision 8: 20/12/2017 Page 3 of 9 \J I RINITY ERD 5.7 Hip and ridge tiles using ICP Adhesives Polyset® AH-160 are limited to projects having hip/ridge design pressure requirements, determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. TABLE 2: HIP & RIDGE TILES IN ICP ADHESIVES POLYSET® AH-160 ALLOWABLE UPLIFT RESISTANCE PERFORMANCE DATA 2 To I MARGIN OFSAFETYALREADYAPPLIED FOR INDEPENDENr(CONTINuousPADDY) PLACEMENT 4 To MARGIN OFSAFErYALREADYAPPLlED FOR INTERDEPENDENT PLACEMENT Allowable Tile Substrate Attachment Method Design Pressure (Psf) Clay 2x PT ridge board Independent: Continuous Paddy (-34 gram/ft) 116 Concrete 2x PT ridge board Independent: Continuous Paddy(-34 gram/ft) 107 Clay 2x PT ridge board Interdependent: Head: One (1) #10 x 2%" screw; 90 Overlap: 1 x 6 inch (-10.5 gram) Concrete 2x PT ridge board Interdependent: Head: One (1) #10 x 2Y=" screw; 56 Overlap: I x 6 inch (-30.5 gram) Clay or Hip & Ridge Channel Metal (FL5374): Independent: Continuous Paddy (-34 gram/ft) 169 Concrete I galvanized only Clay or Trim Lock'" (FL5374): aluminum, Independent: Continuous Paddy (-34 gram/ft) 173 Concrete galvanized, Galvalume® or stainless steel Clay or Trim Lock'" Plus (FL537®): aluminum, Independent: Continuous Paddy (^' 34 gram/ft) 178 Concrete galvanized, Galvalume or stainless el Clay Top Notch (FL8095) Independent: Continuous Paddy (" 32 gram/ft) 125 Concrete Top Notch (FL8095) Independent: Continuous Paddy (" 32 gram/ft) 146 6. INSTALLATION: 6.1 ICP Adhesives Polyset® AH-160 and the tile roof assembly shall be installed in accordance with FRSA/TRI April 2012 (04-22) and ICP Adhesives and Sealants, Inc. published installation instructions, subject to the limitations outlined in Section S. 6.2 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI April 2012 (04-22). Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product Approval. 6.3 Installation shall be performed by applicators who hold a valid Qualified Applicator Card presented by ICP Adhesives and Sealants, Inc. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Tomball, TX 9. QUALITY ASSURANCE ENTITY: UL, LLC. - QUA9625; (847) 664-3623; LeAnna.GfadeckiCdul.COm Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-R8 OCAffi ate Of Authorization R9Sa3 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyset• AH.160, (888) 774-1419 Revision 8: 10/12/2017 Page 4 of 9 JTKINITY � ERD Nall through plastic cement (when required) Paddy (BeneathTlle) Undedayment 10in.x 2 in.wide Battens optional loin.t a-�' 2in. Eave Closure Eave Course Fascia Medium Profile Tile Nailthroughplasticce ent- (when required) Paddy (Beneath Tile) underlayment 10in x 2m.wide i.. Battens optional '•d�. `e F� Eave Course Fascia Weephole 10 in. in. Eave closure �2 Drip edge High Profile Tile 9 Exterior Research and Design, LLC. Evaluation Report 02768.03.06-RB Cert!/lorte of Authorfzadon#9503 6r"EDITION(20171 FBC NON-HVH2 EVALUATION FL6332-R8 ICP Adhesives Polysete AH-160; (888) 774-1419 Revision 8: 10/12/2017 Page 6 of 9 �i TRINITY! ERD 10. PADDY PLACEMENT DETAILS (FROM ICP ADHESIVES AND SEALANTS, INC. PUBLISHED LITERATURE): 10.1 Independent, Medium Paddv: Nail through plastic cement Paddy (Beneath Tile) (when required) Underlayment �f 1t 7i�`�jin. a Battensoptional Eave Course ' o �a 10m J Fascia Eave Closure Flat/Low Profile Tile Nall through plastic cement (when required) •``• Paddy (Beneath Tile) Underlayment IF 71n\, 2In. �• _ Battens optlonal a. 101n. -�• 21n. Eave Closure Eave Course Fascia Medium Profile Tile Nail through plasticce e (when required) Paddy (Beneath Tile) Undedayme\* 71n. 2 In. Battensoptlonal , Eave Coursee � Fascia We iphole loin. tin. Eaveclosure Dripedge High Profile Tile Exterior Research and Design, U.C. Evaluation Report 02768.03.06-RB Certl7fsnte of Authorization P9509 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-RB ICP Adhesives Polysete AH-160: (888) 774-1419 Revision 8: 10/12/2017 Page S of 9 10.3 Interdependent, Two Paddy: Nail through plastic cement - Paddy (between tiles) - lwhen required) Battens opt)onal ° o Paddy(undertile) Single paddy ,.' on top of the - 4 x 4 in. Singlepadd undertil _ onglepaddy on underlayment 2x4in. _. o (r,. 0 Faada 2 in. Eave Cl. Flat/Low Profile Tile on unde w 9x4in. 2x4ie Eave Course 1%�in.'�% 2 in. C��TRINI*ERD Nall through plastic cement Single paddy under tile (when required) Paddy (between tiles) Battens Paddy(undertile) optional /J Single paddy Single paddy on underlayment L, loin. \�' �tin. Eave Closure Eave Course Fascia Medium Profile Tile paddy undertile \ Paddy(betweentiles) }� Paddy(under tile( High Profile Tile Weephole Eaveclosure Drip edge Exterior Research and Design, U.C. Evaluation Report 02768.03.06-RB Ceni/kate o/Autaoritodon#9503 61MEDITION(2017)FBC NON-HVHZ EVALUATION F1.6332-118 ICP Adhesives Polysete AH-160, (888) 774-1419 Revision 8: 10/12/2017 Page 7 of 9 10.4 10.5 Two Piece Barrel (Cal) & Pan) Tile: 11 Place enough adhesive to achieve" to 70 sry in. Steeppitch In contact with the Pan Vie. Iwha n real. 2)Tum Cwan upaleo Oawn. Place tdMaaro- ers m. m und, m rmm addax test mauve. nm. mata. ca crouc. Ensure 2010 36 m. l n. camacl areo on eaM eleeef cover 0la. hnotarshownl Remove top portion of the eave course cover tile.Abut to second mum of pan tiles. Ensure ewe and of pan and cover tiles are flush at ewe line. Two Piece Barrel -High Profile Tile Hip and Ridee (independent placement): A bred ofiCP PohvelBA{I-160msy be %VW slsrvv tho red tge surface m both lid. o(We OiptMRe boaN or pahf mad rural Gam la pr ,. -val elbloci ns. To tench 10Pirdge ties, a bead 011CP Potl.M%14-160 my be eppbed doom tte center of the hywdse bond or pahvmed frame. JI RINITY ERD Exterior Research and Design, U.C. Evaluation Report 02768.03.06-RS CertNRmte ofAuthollmdon a9503 67N EDITION (2017) FeC NON-HVHZ EVALUATION F1.6332-118 ICP Adhesives Palysete AH-160: (8881774-1419 Revision 8: 10/12/2017 Page 8 of 9 10.6 Hip and Ridee (interdependent placement): END OF EVALUATION REPORT - �J I KININ I ERD Exterior Research and Design, U.C. Evaluation Report 02768.03.06-R8 Cert!&ote OfAuthor7io0on#9503 EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-RB ICP Adhesives Polyset° AN-160; (888) 774-1419 Revision 8:10/12/2017 Page 9 of 9 r, 0 ENGINEER EVALUATE TEST EVALUATION REPORT Polyglass USA, Inc. 1111 West Newport Center Drive Deerfield Beach, FL 33442 (954)233-1230 DEMO l etc. Certificate Of A uthorizotion #32455 353 Christian Street, Unit #13 Oxford, CT06478 (203) 262-9245 CONSULT CERTIFY Evaluation Report P12060.02.09-1124 FL5259-R28 Date of Issuance:02/24/2009 Revision 24: 01/24/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 60b Edition (2017) Florida Building Code sG ANPIM herein. BY DESCRIPTION: Polyglass Roof Underlayments St. Lucie County LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMOIetc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 14. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 01/24/2018. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMOietc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMOl etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO Jetc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMOletc. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the a Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Pro a Standard Year 1504.3.1 Wind Uplift FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.2.3 / 1507.1.1 Physical Properties ASTM D226 2009 1507.2.4 / 1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES:- ` Enti Examination Reference Date FM Approvals (TST 1867) Wind Uplift 3004091 01/12/2000 PRI (TST 5878) Physical Properties PRIO1111 04/08/2002 PRI (TST 5878) Physical Properties PUSA-005-02-01 01/31/2002 PRI (TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI (TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI (TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI (TST 5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI (TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI (TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI (TST 5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI (TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRI (TST 5878) Physical Properties PUSA-083-02-01 04/14/2008 PRI (TST 5878) Physical Properties PUSA-088-02-01 07/29/2009 MTI (TST 2508) Physical Properties JX20H7A 04/01/2008 MTI (TST 2508) Physical Properties RX14E8A 01/29/2009 ERD (TST 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD (TST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD (TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD (TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD (TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD (TST 6049) Physical Properties P5110.04.07-1 D4/11/2007 ERD (TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD (TST 6049) Physical Properties P13450.08.09 08/13/2009 ERD (TST 6049) Wind Uplift P30540.11.09-R1 11/30/2009 ERD (TST 6049) Physical Properties P11030.11.09-1 11/30/2009 ERD (TST 6049) Wind Uplift P11030.11.09-2 11/30/2009 ERD (TST 6049) Physical Properties P31030.11.09-3 11/30/2009 ERD (TST 6049) Physical Properties P33360.06.10 06/25/2010 ERD (TST 6049) Physical Properties P33370.03.11 03/02/2011 ERD (TST 6049) Physical Properties P33370.04.11 04/26/2011 ERD (TST 6049) Physical Properties P37300.10.11 10/19/2011 NEMO ETC, U.C. Evaluation Report P12060.02.09-1124 Cert/fimte of Authorizotion#32455 6r"EDITION (2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 2 of 14 ON EMO etc. i1afty. Examination Reference Date ERD (TST 6049) Physical Properties P40390.08.12-1 08/06/2012 ERD (TST 6049) Physical Properties- P40390.08.12-2 08/07/2012 ERD (TST 6049) Physical Properties C41420.09.12-3 09/11/2012 ERD (TST 6049) Wind Uplift P39680.03.13 03/04/2013 ERD (TST 6049) Physical Properties P45370.04.13 04/26/2013 ERD (TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013 ERD (TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 ERD (TST 6049) Wind Uplift P41630.08.13 08/06/2013 ERD (TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013 ERD (TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013 ERD (TST6049) Physical Properties P45270.05.14 05/12/2014 ERD (TST 6049) Physical Properties 6020.07.14-1 09/08/2014 ERD (TST 6049) Physical Properties 602D.09.14-2 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-3 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-4 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-5 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-6 09/08/2014 ERD (TST 6049) Physical Properties P46520.10.14 10/03/2014 ERD (TST 6049) Physical Properties P43290.10.14 10/17/2014 ERD (TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015 ERD (TST 6049) Physical Properties. P40390.04.15 04/03/2015 ERD (TST 6049) Physical Properties P44360.10.14-R1 05/18/2015 ERD (TST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015 ERD (TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016 ERD (TST 6049) Physical Properties PLYG-SC8080.07.16 07/16/2016 ERD (TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016 ERD (TST 6049) Physical Properties PLYG-SC13040.12.16 12/27/2016 ERD (TST 6049) Physical Properties PLYG-SC11900.03.17 03/10/2017 ERD (TST 6049) Physical Properties PLYG-SC12115.08.17 08/08/2017 ICC-ES(EVL 2396) IBC Compliance ESR-1697 11/01/2014 Miami -Dade (CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015 Polyglass USA Manufacturing Affidavit Products Current 02/18/2009 Polyglass USA P/L Affidavit Mule -Hide Cross Ltg 03/01/2008 Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011 UL, LLC. (QUA9625) Quality Control Service Confirmation Exp.10/05/2018 4. PRODUCT DESCRIPTION: 4.1 Mechanically Fastened Underlayments: 4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet. 4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet. 4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet. 4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet. 4.2 Self -Adhering Underlayments: 4.2.1 Polystick MTS or Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with palyolefinic film surface; meets FRSA/TRI April 2012. 4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM D1970. 4.2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. NEMO ETC, U.C. Evaluation Report P32060.02.09-R24 CertiJlcate of Authorization#32455 6'"EDITION (2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233.1230 Revision 24:01/24/2018 Page 3 of 24 ONEMOletc. 4.2.4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface; meets FRSA/TRI April 2012. 4.2.5 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m1 polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. 4.2.6 Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester reinforced, APP modified bitumen cap sheets; meet FRSA/TRI April 2012. 4.2.7 Polystick Dual Prom is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D1970. 4.2.8 Polystick Tile ProTM is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. 4.2.9 Polystick MU-X is a nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section 5.8). 4.3 Mechanically. Fastened and/or Bonded Underlayments: 4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SBS modified bitumen back -side and granule -surfaced APP modified bitumen top -side. Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. 4.3.2 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164. Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet' in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an alternate to Hot Asphalt applied "Cap Sheet' in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. 4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222. Polyflex G is for use as an alternate to Heat Applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat Applied "Cap Sheet' in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMOIetc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. NEW ETC, I.I.C. Evaluation Report P32060.02.09-R24 Certificate of Authorization 4324s5 6r" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZ8 Polyglass Roof Underlayments; 1954) 233-1230 Revision 24: 01/24/2018 Page 4 of 14 ONEMO etc. 5.5 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS - -- Underlayment Asphalt5hingles Nail -On Tile Foam -On Tile Metal Wood Shakes & Shingles Slate Elastobase Yes Yes (Base Sheet in 2-ply system) Yes (Base Sheet in 2-ply system) Yes Yes Yes Elastobase P Yes Yes (Base Sheet In 2-ply system) Yes (Base Sheet In 2-ply system) yes Yes Yes Polyglass G2 Base No Yes (Base Sheet in 2-ply system) Yes (Base Sheet in 2-pry system) No No No Polyglass APP Base No Yes (Base Sheet In 2-ply system) Yes (Base Sheet In 2-ply system) No No No Polystick MTS or MTS PLUS Yes Yes No Yes Yes Yes Polystick lR-Xe Yes No No No Yes Yes PolystickTUP No Yes Yes (See 5.5.1) No No No Polystick TU Plus Yes Yes Yes (See 5.5.1) Yes Yes Yes Polystick TU Max 34 No Yes Yes (See 5.5.1) Yes No No Polystick Dual Pro Yes No No Yes Yes Yes Polystick Tile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes Polystick MU-X Yes No No Yes Yes Yes Elastoflex 56G Yes Yes Yes (See 5.5.1) No Yes Yes Elastaflex S6 G FR Yes Yes No No Yes Yes Elastoflex G TU Yes Yes Yes (See 5.5.1) No Yes Yes PolyflexG Yes Yes Yes (See 5.5.1) No Yes Yes Polyflex G FR Yes Yes No No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes (See 5.5.1) No Yes Yes Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet FR) Yes Yes Yes (See 5.5.1) No Yes Yes 5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. TABLE 1A: ALLOWABLE TILE ADHESIVE/ UNDERLAYMENT COMBINATIONS) Adhesive Florida Product Underlayments Approval DAP Foam Touch'n Seal Storm Bond Roof Tile Adhesive FL14506 Polystick TU Plus, Polystick TU Max Dow TileBond"' FL22525 Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, ICP Adhesives Polyset® AH-160 FL6332 Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, ICP Adhesives Polyset® RTA-1 FL6276 Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FRI 2 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R24 CertiFcote of Authoritarian#32455 6t"EDITION (2017)FBC NON-HVH2 EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233.1230 Revision 24: 01/24/2018 Page 5 of 14 Allowable Substrates: ONEMOletc. 5.6.1 Direct -Bond to Deck: Qi� Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note: Polyglass does not require priming of new or existing plywood Or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex G TU, Elastoflex S6 G or Elastoflex 56 G FR in hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or Polyflex G FR torch -applied to: ➢ ASTM D41 primed structural concrete. 5.6.2 Bond -to -Insulation: Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. Polyflex G or Polyflex G FR torch -applied to: ➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FBC Section 1504.3.1. 5.6.3 Bond to Mechanically Attached Base Layer: Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: ➢ ASTM D226, Type i or 11 felt; Elastobase; Elastobase P or Mule -Hide Nail Base. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D226, Type I or 11 felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base. Polyflex G or Polyflex G FR torch -applied to: ➢ Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC Section 1504.3.1. NENIO ETC, I.I.C. Evaluation Report P32060.02.09-R24 Certi/imte of Authorization #32455 CH EDITION (2017) FBC NON-HVHZ EVALUATION FL5269-R28 Polyglass Roof Underlayments; (964) Z33-1230 Revision 24: 01/24/2018 Page 6 of 14 NNEMOletc. 5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04- �� 12), Appendix A, Table SA or FBC 1609 for determination of design wind loads. �tl j Maximum Design Pressure =-90 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #2 Maximum Design Pressure=-97.5 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x I%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. #3 Maximum Design Pressure=-105 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x I%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. #4 Maximum Design Pressure =-135 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Joints: Min. 4-Inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #5 Maximum Design Pressure=-315 osf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS or Polystick MIS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #6 Maximum Design Pressure = -622.5 osf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG1O0 or ASTM D41 Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #7 Maximum Design Pressure=-30.0 Dsf': Deck: Min. 15/32-Inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch long x 1-Inch head diameter round metal cap nails Spacing: 6-Inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. NEMO ETC, U.C. Evaluation Report P320E0.02.09-R24 Certificate of Authorization#32455 eEDITION 12017)FBC NON-HVHZ EVALUATION FL5259-R28 Potyglass Roof Underlayments; (954) 233-1230 Revision 24:01/24/2018 Page 7 of 14 ONEMOletc. #8 Maximum Design Pressure=-37.5 osf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-Inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #9 Maximum Design Pressure = -37.5 psf*: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) or two (2) layers ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. #10 Maximum Design Pressure =-45 osf*: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) layer ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c. at the 2-inch wide side laps and 4-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU, applied In full mopping of hot asphalt. #11 Maximum Design Pressure =-45 osf*: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Two (2) layers ASTM D226, Type 11 felt Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 9-inch o.c. at the 2-inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. #12 Maximum Design Pressure=-45 osf Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt ortorch-applied cap or poly -film surface fortorch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #13 Maximum Design Pressure = -52.5 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #14 Maximum Design Pressure =-52.5 osf Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. NEMO ETC, I.I.C. Evaluation Report P32060.02.09-R24 certificate of Authorization a32455 EDITION (2017) FBC NON-HVH2 EVALUATION FL5259-R28 Polyglass Roof Underiayments; (954) 233-1230 Revision 24: 01/24/2018 Page 8 of 14 ONEMOletc. #15 Maximum Design Pressure=-52.5 osf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sandedtop surface for hot -asphalt or torch -applied tap or poly -film -surface for torch=applled-cap) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #16 Maximum Design Pressure =-60 Dsf: Deck: Min. 19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #17 Maximum Design Pressure =-60 Dsf: Deck: Min. 19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: CMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #18 Maximum Design Pressure=-67.5 osf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underloyment) Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch - applied. #19 Maximum Design Pressure =-75 osf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underloyment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 10-inch o.c. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch - applied. #20 Maximum Design Pressure =-90 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase sanded to surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied ca ( P P PP P P Y PP P) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #21 Maximum Design Pressure=-90 Dsf: Deck: - Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied. #22 Maximum Design Pressure =-90Dsf: Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. NEMO ETC, U.C. Evaluation Report P32060.02.09-R24 Certificate of Authorl:ation#32455 61X EDITION 12017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments, (954) 233.1230 Revision 24: 01/24/2018 Page 9 of 14 ONEMOletc. #23 Maximum Design Pressure=-90 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base -or Polyglass APP Base (requires use of torch -applied underloyment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with CMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch - applied. #24 Maximum Design Pressure=-97.5 osf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-Inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #25 Maximum Design Pressure =-105 Dsf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-Inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #26 Maximum Design Pressure=-112.5 osf Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer at all tin -caps Base Ply: Polystick MTS or Polystick MTS PLUS, self -adhered Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FRI, self -adhered. #27 Maximum Design Pressure =-120 Dsf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt ortorch-applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-Inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #28 Maximum Design Pressure=-120 osf Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3" Metal Insulation Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. 5.6.4.1 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of -45 psf. NEMO ETC, I.I.C. Evaluation Report P32060.02.09-R24 Certpimte of Authorization p32455 6r"EDITION (2017)FBC NON-HVHZ EVALUATION FL5259-RZB Polyglass Roof Underlayments; (954) 233.1230 Revision 24: 01/24/2018 Page 10 of 14 ONEMO etc. 5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table SA. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD3, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days after installation. Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation. Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for longer than 180-days after installation. Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30 days. Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum exposure is 180 days. 5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth in Section 4.3, Note 1 of ASTM D3970-15, should be established as to slip resistance. 5.9 Tile Slippage Limitations (FRSA/TRI April 2012 (04-12))• When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2:, TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECKTILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Elastoflex G TU Flat 10-tile stack 7:12 Lugged 8-tile stack (6 over 2) 6:12 Elastoflex S6 G or S6 G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polystick MTS or MTS PLUS Flat 6-tile stack (4 over 2) 5:12 Lugged 6-tile stack (4 over 2) 4:12 Polystick Tile Pro Flat or Lugged 6-tile stack (4 over 2) 7:12 Polystick TU Max Flat 6-tile stack (4 over 2) or 10-tile stack 7:12 Lugged 6-tile stack (4 over 2) 7:12 Lugged 10-tile stack 6:12 Polystick TU P Flat 6-tile stack (4 over 2) 6:12 Lugged 6-tile stack (4 over 2) 4:12 Polystick TU Plus Flat or Lugged 6-tile stack (4 over 2) 7:12 Flat or Lugged 10-tile stack 6:12 Polyflex G or G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6-tile stack (4 over 2) 4:12 NEMO ETC, U.C. Evaluation Report P32060.02.09-R24 Certiiftote ofAothorlrotion k32455 6'"EDITION (20171 FBC NON-HVHZ EVALUATION FL5259-RZB Polyglass Roof Underlayments; (954) 233-1230 Revision 24:01/24/2018 Page 11 of 14 ONEMOletc. 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Elastobase, Elastobase P or Mule -Hide Nail Base: 6.3.1 Non -Tile Applications: Shall be installed in compliance with the codified requirements for ASTM D226, Type 11 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table 1. 6.3.2 Tile Applications: Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with FRSA/TRI April2012 (04-12) Installation Manual. 6.4 Polystick MTS,.MTS PLUS, IR-Xe, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or MU-X or Polyflex SAP, Polyflex SAP FR, Mule-HideSA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR): 6.4.1 Shall be installed in compliance with the endified remllrPrnentC fnr CSTM nt g7n Icvrant Pnlvstick TH PI underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.4.2 Direct -to -Deck with Mechanically Fastened Roof Covers: All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule - Hide back nailing guidelines. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back - nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back -nailed. All seal -lap seams (selvage laps) must be aj+; e, a+ firmly rolled with a minimum 28 lb. hand , roller to ensure full contact and adhesion. 'i •' For Dual Pro and Tile Pro, align the edge of^^�? the top sheet to the end of the glue pattern f �.f t `' (the sheet will overlap the fabric). , y i e View of Ovelap Seam of Dual Pro and Tile Pro All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap. Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details NEMO ETC, U.C. Evaluation Report P32060.02.09-1124 Cert/ficote ofAuthorizotlon k32455 eEDITION (2017)FBC NON-HVRZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24:01/24/2018 Page 12 of 14 ONEW10jetc. Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PGSOD Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the - —Polystick-material-of-like-kind, set -and -hand -rolled -in -place over -the repair area.— -Patch laps, -if needed, —shall -be installed in a water shedding manner. All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 Tile Applications (not allowed for Polystick Dual Pro. IR-Xe or Polystick MU -XI - Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1. For adhesive -set tile applications, refer to Section 5.6.4 herein. 6.4.4 Two (2) Ply Underlavment Systems: Polystick MTS or MTS PLUS followed by Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. Polystick MTS or MTS PLUS followed by Polystick TU P, TU Plus, TU Max, Tile Pro or Polyflex SAP is allowable for use under foam -on tile systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. 6.5 Elastoflex G TU,.Elastoflex S6:G:Or Elastoflex SIS G FR: 6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. 6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt -applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6.6 Polyflex G or Polyflex G FR: 6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems (Base Sheet Limited per 5.6.3). ✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet' in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems (Base Sheet Limited per 5.6.3). NEMO ETC, U.C. Evaluation Report P32060.02.09-R24 Cerfftate Of Autharuation#32455 eH EDITION(20171 FRC NON-HVH2 EVALUATION FL5259-RZS Polyglass Roof Underlayments; (954) 233-1230 Revision 24:01/24/2018 Page 13 of 14 ON EMO etc. 6.6.2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. 6_7 Tile Staging: 6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and Polyglass published requirements for tile staging. 6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail- boards, to prevent tile sliding and/or damage to the underlayment during the loading process. 6.7.3 Polyglass specifies the minimum cure time after installation of self -adhering membranes and before loading of roofing tiles is forty-eight (48) hours. BUILDING PERMIT REQUIREMENTS: As required by the Building Official Or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted CIA agency for information on product locations covered for F.A.C. 61G20-3 CIA requirements. The following plants have qualified products under their respective physical properties specifications. Plant Specification Product s Fernley, NV, Hazleton, PA & Winter Haven, FL ASTM D1970 Polystick MU-X Hazleton, PA M-D 13-0004 Elastoflex G TU Hazleton, PA & Winter Haven, FL ASTM D1970 Polystick IR-Xe ASTM D1970 & FRSA/TRI April 2012 Polystick TU Plus ASTM D1970 & FRSA/TRI April 2012 Polystick TU Max Tuscaloosa, AL ASTM D4601, Type II Polyglass G2 Base Winter Haven, FL ASTM D226 (physicals) Elastobase, Elastobase P ASTM D6509 Polyglass APP Base FRSA/TRI April 2012 Polystick NITS, Polystick MTS PLUS FRSA/TRI April 2012 Polystick TU P FRSA/TRI April 2012 Polyflex SAP, Polyflex SA P FR ASTM D1970 Polystick Dual Pro ASTM D1970 & FRSA/TRI April 2012 Polystick Tile Pro ASTM D6164 Elastoflex S6, Elastoflex S6 G FR ASTM D6222 Polyflex G, Polyflex G FR 9. QUALITY ASSURANCE ENTITY: UL, LLC— QUA9625; (314) 578-3406; k.chancellor@us.ul.com END OF EVALUATION REPORT - NEMO ETC, U.C. Evaluation Report P12060.02.09-R24 Certifiwte of Aothorization#32455 eEDITION 12017)FBC NON-HVH2 EVALUATION F1.5259-1128 Polyglass Roof Underlayments; 1954) 233-1230 'Revision 24: 01/24/2018 Page 14 of 14