HomeMy WebLinkAboutPRODUCT EVALUATION REPORTProduct Evaluation Report
67G2U-3 F.A.C. I Report No. 2000, Rev. 2 1
Manufacturer
Maxim Industries, Inc
1630 Terre Colony Court
Dallas, TX 75212
ect No. 418-0102 1 3/2/18 1 Page 1 of 2 SCANNED
BY
Product Series. Model and/or Description St. Lucie County
Series "DCM" Dade Curb Mount Skylight
Series "DSF" Dade Self -Flashing Skylight
Code: Current Edition of the Florida Building Code including the 61^ Edition (2017) Florida Building Code
Compliance Methods: Product Approval Rule 61G20-3.005(1)(D) — Product Evaluation Report by a License Professional
Engineer
Product Installation Instructions:
• MAX0001, Rev. C, dated 3/2/18, signed and sealed by RobertJ. Amoruso, Maxim Industries, Inc. Series "DSF" Dade
Self -Flashing Skylight, Installation Anchorage Details
• MAX0002, Rev. C, dated 3/2/18, signed and sealed by Robert J. Amoruso, Maxim Industries, Inc. Series "DCM"
Dade Curb Mount Skylight, Installation Anchorage Details
Product Testing:
• Architectural Testing Inc. Test Report No. 01-43381.01, dated 01/29/03, signed and sealed by Steve Urich, P.E.,
testing to TAS 201-94, TAS 202-94 and TAS 203-94
Engineering Analysis & Product Evaluation: The following engineering and/or rational analysis/calculations have been
performed.
• Anchorage and product verification has been substantiated by calculation (PTC Report. No.1591, Rev. 0) prepared,
signed and sealed by Robert.]. Amoruso, P.E. in accordance with the current edition of the Florida Building Code.
• Design Pressure Evaluation/Product Evaluation
o Drawing No. MAX0001 & MAX0002
• High Velocity Hurricane Zone (HVHZ): YES
• Outside High Velocity Hurricane Zone (HVHZ): YES
• Impact Resistant: YES
• Skylight domes using Covestro LLC Makrolon Polycarbonate Panels (Makrolon° (formerly
Hyzod•) is a trade name for Covestro (formerly Bayer Material Sciences).
o Architectural Testing Inc. Test Report No. 01-43381.01, dated 01/29/03, signed and sealed by Steve Urich,
P.E.
• Design Pressure Evaluation based on testing
• Margin of Safety = positive loading 3 and negative loading 2 for plastic skylight domes
applied to Structural Design Pressure per MD FAQ
(http://www.miamidade.goy/building/products/Skylights.aso) and meeting/exceeding
current FBC requirements.
• +180/-120 psf Structural Design Pressure
o 180/3 -+60 psf & 120/2 = -60 psf DP
• +9 psf Water Test Pressure equates to 6.06/.15 =+60 psf DP
• Cyclic Test Pressure per TAS 203 was+/-60 psf
• Design Pressure =+/-60 psf
o Performance and Testing Standards
• TAS201-94
• TAS 202-04
• TAS203-94
FTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752.0775