HomeMy WebLinkAboutPRODUCT EVALUATION REPORTProduct Evaluation Report 67G2U-3 F.A.C. I Report No. 2000, Rev. 2 1 Manufacturer Maxim Industries, Inc 1630 Terre Colony Court Dallas, TX 75212 ect No. 418-0102 1 3/2/18 1 Page 1 of 2 SCANNED BY Product Series. Model and/or Description St. Lucie County Series "DCM" Dade Curb Mount Skylight Series "DSF" Dade Self -Flashing Skylight Code: Current Edition of the Florida Building Code including the 61^ Edition (2017) Florida Building Code Compliance Methods: Product Approval Rule 61G20-3.005(1)(D) — Product Evaluation Report by a License Professional Engineer Product Installation Instructions: • MAX0001, Rev. C, dated 3/2/18, signed and sealed by RobertJ. Amoruso, Maxim Industries, Inc. Series "DSF" Dade Self -Flashing Skylight, Installation Anchorage Details • MAX0002, Rev. C, dated 3/2/18, signed and sealed by Robert J. Amoruso, Maxim Industries, Inc. Series "DCM" Dade Curb Mount Skylight, Installation Anchorage Details Product Testing: • Architectural Testing Inc. Test Report No. 01-43381.01, dated 01/29/03, signed and sealed by Steve Urich, P.E., testing to TAS 201-94, TAS 202-94 and TAS 203-94 Engineering Analysis & Product Evaluation: The following engineering and/or rational analysis/calculations have been performed. • Anchorage and product verification has been substantiated by calculation (PTC Report. No.1591, Rev. 0) prepared, signed and sealed by Robert.]. Amoruso, P.E. in accordance with the current edition of the Florida Building Code. • Design Pressure Evaluation/Product Evaluation o Drawing No. MAX0001 & MAX0002 • High Velocity Hurricane Zone (HVHZ): YES • Outside High Velocity Hurricane Zone (HVHZ): YES • Impact Resistant: YES • Skylight domes using Covestro LLC Makrolon Polycarbonate Panels (Makrolon° (formerly Hyzod•) is a trade name for Covestro (formerly Bayer Material Sciences). o Architectural Testing Inc. Test Report No. 01-43381.01, dated 01/29/03, signed and sealed by Steve Urich, P.E. • Design Pressure Evaluation based on testing • Margin of Safety = positive loading 3 and negative loading 2 for plastic skylight domes applied to Structural Design Pressure per MD FAQ (http://www.miamidade.goy/building/products/Skylights.aso) and meeting/exceeding current FBC requirements. • +180/-120 psf Structural Design Pressure o 180/3 -+60 psf & 120/2 = -60 psf DP • +9 psf Water Test Pressure equates to 6.06/.15 =+60 psf DP • Cyclic Test Pressure per TAS 203 was+/-60 psf • Design Pressure =+/-60 psf o Performance and Testing Standards • TAS201-94 • TAS 202-04 • TAS203-94 FTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752.0775 Jr�L 321.690-1788 1 FBPE Certification of Authorization No. 25935